Recommended Practice for Thrust Measurement in Electric Propulsion Testing

James E Polk 1, Anthony Pancotti 2, Thomas Haag 3, Scott King 4, Mitchell Walker 5, Joseph Blakely 6, John Ziemer 7
PMCID: PMC7839308  NIHMSID: NIHMS1535824  PMID: 33510551

Abstract

Accurate, direct measurement of thrust or impulse is one of the most critical elements of electric thruster characterization, and one of the most difficult measurements to make. This paper summarizes recommended practices for the design, calibration, and operation of pendulum thrust stands, which are widely recognized as the best approach for measuring μN- to mN-level thrust and μNs-level impulse bits. The fundamentals of pendulum thrust stand operation are reviewed, along with the implementation of hanging pendulum, inverted pendulum, and torsional balance configurations. Methods of calibration and recommendations for calibration processes are presented. Sources of error are identified and methods for data processing and uncertainty analysis are discussed. This review is intended to be the first step toward a recommended practices document to help the community produce high quality thrust measurements.

I. Introduction

As part of a larger effort by the American Institute of Aeronautics and Astronautics (AIAA) Electric Propulsion Technical Committee to provide standards for electric thruster measurement and test, we have developed recommendations for direct thrust measurements. Measurement of thrust is one of the most fundamental requirements in thruster performance characterization. Because electric thrusters produce relatively low thrust levels, direct thrust measurements can be challenging. Thrust measurements are particularly difficult for microthrusters, which have enjoyed increased attention in the last two decades. Considerable effort and talent has been invested in developing sensitive thrust stands and measurement techniques, and one objective of the AIAA initiative is to capture this knowledge and distill it for the community.

The purpose of this paper is to recommend best practices for the use of the most common types of pendulum thrust stands based on experience from the community, not to specify a particular thrust stand design that must be used to produce credible results. These recommendations include best practices for the design, calibration, and operation of pendulum thrust stands and the analysis of thrust stand data with a particular focus on cataloguing sources of error and estimating the uncertainty in the measurements. The goals are to help users avoid common mistakes, improve the quality of thrust stand measurements with proven approaches to thrust stand use, and provide guidelines for reporting results to make it easier to evaluate the reliability of thrust stand measurements.

This paper provides an overview of the three types of pendulum thrust stands (inverted, hanging, and torsional), including the dynamics that underlie their operation and key performance metrics. Typical implementations and how they are optimized are then described. Methods for calibration, operation, and data analysis are discussed along with typical sources of error, methods to control errors, and the process of estimating measurement uncertainties. Finally, we provide a list of items that should be included when reporting thrust measurements.

II. Thrust Stands for Electric Propulsion

A. Overview

High thrust devices are often tested on load cells. However, because most electric thrusters have low thrust-to-weight ratios, a load cell signal would be dominated by the weight of the thruster. To address this issue, the thrust or impulse bit from electric thrusters is typically inferred from the motion of pendulum thrust stands. Three major configurations-hanging pendulums, inverted pendulums, and torsional pendulums-are used to make accurate steady-state and impulse thrust measurements. All of these configurations are variations of a spring-mass-damper system, as illustrated in Fig. (1). While each of these implementations has its advantages and disadvantages, pendulum thrust stands in general are widely accepted as a reliable way to make direct thrust measurements with electric thrusters.

Fig. 1.

Fig. 1

State-of-the-art thrust stands for electric thrusters can be considered torsional pendulums, hanging pendulums, or inverted pendulums.

B. Pendulum Thrust Stand Dynamics.

Many characteristics of pendulum thrust stands can be understood by examining three solutions to the equation of motion for ideal pendulums. The equation of motion for a second order system relates the time rate of change of angular momentum to the sum of torques due to torsional springs, dampers, and applied forces [1]. The dynamics of all three types of pendulums are described by the same equation,

Iθ¨+cθ˙+kθ=F(t)L, (1)

where θ is the angular position relative to a reference position, I is the moment of inertia, c is the damping constant, k is the effective spring constant associated with restoring forces, and F(t) is an applied force acting at a distance L from the pivot that produces a torque on the system. I, c, and k are assumed to be constants. Actual thrust stands may include active components such as electronic dampers where the damping constant is frequency dependent, which complicates the analysis. This equation can be cast in the standard form

θ¨+2ζωnθ˙+ωn2θ=F(t)L/I, (2)

where ζ is the damping coefficient,

ζ=c21Ik (3)

and ωn is the natural frequency of the undamped system,

ωn=kI. (4)

The primary difference in the three types of pendulum thrust stands is the effect of the gravity force on the dynamics. Gravity acts as a restoring force in hanging pendulums, a force tending to increase the deflection in inverted pendulums, and has no influence on ideal torsional pendulums where the plane of motion is perpendicular to the gravity vector. The torque associated with the gravitational force in hanging and inverted pendulums is

Tg=mgLcmsinθmgLcmθ, (5)

where m is the mass, g is the acceleration due to gravity, and Lcm is the distance from the center of mass to the pivot point. The second expression is valid for small deflection angles. For example, the error in the gravitational torque associated with this approximation is less than 0.13% for angles of 5° or less. In this approximation where the gravity torque is proportional to the deflection, it can be incorporated in the spring torque term of Eqn. (1),

k={ks+mgLcmfor hanging pendulumsksmgLcmfor inverted pendulums (6)

Clearly, for inverted pendulums the gravity torque must not exceed the spring torque, otherwise the restoring force is negative and the pendulum is unstable.

Equation (2) can be solved to give the response of a pendulum to an arbitrary input force. Three special cases with analytical solutions are particularly relevant for pendulum thrust stands. The dynamic motion of a pendulum thrust stand subject to the torque produced by a constant thrust Ft from a steady-state thruster applied at a distance Lt from the pivot can be approximated by the response of an ideal pendulum to a step input with initial conditions θ(0)=θ˙(0)=0, where

F(t)={0for t<0.Ftfor t0. (7)

The deflection θ(t) normalized by the steady-state deflection

θss=FtLtIωn2=FtLtk (8)

depends on the damping coefficient,

θ(t)Iωn2FtLt=θ(t)θSS={1eζωnt[cos(ωdt)+ζ1ζ2sin(ωdt)]forζ<1(underdamped)1eωnt(1ωnt)forζ=1(critically damped)1+12ζ21[1d1ed1ωnt1d2ed2ωnt]forζ>1(overdamped). (9)

In these expressions ωd=ωn1ζ2 is the frequency of the damped motion, d1=ζζ21, and d2=ζ+ζ21. Example responses plotted in Fig. (2) show that the time required to reach the steady-state deflection depends on the damping coefficient. The settling time, defined as the time required to settle within 2% of the steady-state deflection, is about one period for critically damped pendulums and depends on the damping coefficient for overdamped and underdamped pendulums. This is a fundamental limit on the response time for step changes in thrust levels for pendulum thrust stands.

Fig. 2.

Fig. 2

Response of under-, over-, and critically-damped pendulums to a step input, normalized by the steady-state deflection.

The response of a pendulum thrust stand to the impulse bit from a pulsed thruster applied at a distance Lt from the pivot may be approximated by the solution to Eqn. (2) for an impulse input F(t) = Ibitδ(t), where δ(t) is the Dirac delta function, with initial conditions θ(0)=θ˙(0)=0:

θ(t)IωnIbitLt={11ζ2eζωntsin(ωdt)ifζ<1(underdamped)ωnteωntifζ=1(critically damped)12ζ21[ed1ωnted2ωnt]ifζ>1(overdamped). (10)

Example solutions plotted in Fig. (3) show that the response is a transient with a decay time determined by the damping coefficient. As the expanded plot in the upper right portion of this figure suggests, all three curves have the same initial slope, reflecting that fact that the initial angular velocity produced by the impulse is independent of the damping coefficient. The change in velocity due to the impulse is

Δθ˙(0)=IbitLt/I. (11)

Fig. 3.

Fig. 3

Normalized response of under-, over-, and critically-damped pendulums to an impulse input. The expanded view in the upper right shows that the initial velocity is the same for all three curves.

It can be also be shown that the maximum amplitude θm and the range (difference between the first peak and the first valley) of the response is proportional to the impulse bit. For example, for an undamped oscillator (ζ = 0), the maximum amplitude is

θm=IbitLt/Iωn. (12)

The peak amplitude and range decrease as the damping coefficient increases. The equations of motion can also be solved for finite pulse lengths [2] and for repeated impulses [3].

If the force on the thrust stand is time-varying, the response also varies in time and the amplitude depends on the frequency of the applied force compared to the natural frequency of the stand. For a periodic forcing function of the form F(t)=F¯tcos(ωt), the response will initially include a transient component at a frequency of ωd and a steady-state component at the driving frequency ω. After the transient response dies out, the amplitude of the steady-state oscillation compared to the deflection θst=F¯tLt/k due to a static load of F¯t is

θ¯θst=1[(1Ω2)2+(2ζΩ)2]1/2, (13)

where Ω = ω/ωn. This function is plotted in Fig. (4) for a range of damping ratios. For critically-damped (and over-damped) pendulums, the response amplitude decays monotonically with input frequency. As expected though, under-damped pendulums can have an amplified response when the driving frequency approaches the resonant frequency of the stand. For frequencies above the resonance, the response is attenuated. The sensitivity of a pendulum thrust stand to dynamic thrust loads therefore varies with frequency.

Fig. 4.

Fig. 4

Amplitude of pendulum response due to a periodic force F(t)=F¯tcos(ωt),, normalized by the deflection θst due to a static load F¯t.

C. Thrust Stand Performance Metrics

The quality of thrust measurements depends on six thrust stand performance metrics, which we review in this section. Ways to characterize these parameters and achieve high thrust stand performance are discussed in subsequent sections.

1. Sensitivity.

The thrust stand sensitivity is one of the most important figures of merit, because it largely determines the precision and resolution of thrust measurements. The sensitivity for a steady-state thrust measurement can be defined as the deflection achieved for a given applied force. As Eqn. (8) shows, this depends on the length of the moment arm Lt and the effective spring constant k and is therefore a key mechanical design feature of the stand.

In practice, the sensitivity depends on the ability to measure the deflection, and is often expressed as the voltage output of a position transducer for a given force, [V/N]. There are many ways to measure the angular deflection as a function of time, θ(t). For small deflections where the small angle approximation is valid, the linear displacement x(t)Lpmθ(t) at a point a distance Lpm from the pivot can be measured. Often, the linear displacement can be measured more accurately than the angular deflection, but at the expense of error introduced by the need to measure Lpm. In this case the sensitivity is given by

xss/Ft=LpmLt/k=LpmLt/Iωn2 (14)

where xss is the steady-state position. This is typically reported as the position sensor output Vss = Gxss where G is the sensor responsivity in [V/m]. The responsivity is an important design parameter, and a very sensitive transducer may compensate for small deflections, which may be necessary to remain in the linear regime or because of other constraints.

For impulse measurements, the sensitivity may be defined as the initial velocity of the pendulum or the maximum deflection obtained for a given impulse, for example

Δx˙(0)/Ibit=LpmLt/I. (15)

This can be similarly translated into the response of a transducer to a given input.

As noted above, the thrust stand sensitivity can vary with frequency for dynamic thrust loads. To achieve a flat response for relevant thrust input frequencies, the stand should be designed to be under-damped with a damping ratio of ~ 0.5 — 0.6 and a natural frequency much higher than the input frequencies. High natural frequencies can be achieved with high stiffness or low moment of inertia. Of these strategies, decreasing moment of inertia is preferred, otherwise sensitivity (which scales inversely with stiffness) will be sacrificed for flat response. The amplification in response near the resonant frequency has been exploited in at least one design [4] to increase sensitivity. In this approach a pulsed thruster was fired every half period at the natural frequency of a minimally damped torsional thrust stand in order to amplify the amplitude of the stand oscillation and achieve sub-micronewton sensitivity.

Although the sensitivity can be estimated from the design parameters in Eqn. (14), a value determined by calibration with known forces or impulses should be used to accurately calculate the thrust or impulse bit associated with a measured deflection. If the sensitivity is calibrated directly by applying known forces or impulses at Lt, then the geometric parameters such as Lt and Lpm do not need to be known. Calibration of the thrust stand response is one of the most important steps in thrust measurement, and is discussed in detail in Section IV.

2. Repeatability and Long-term Stability.

The use of a sensitivity calibration performed before and/or after a thrust measurement relies on the assumption that the thrust stand response is repeatable, so this has a first order impact on measurement accuracy. Stability of thrust stand response is also important in long duration, time-resolved thrust measurements. Repeatability can be affected by two factors: (1) drifts that cause a shift in the apparent or real position of the pendulum (zero shifts) and (2) variability in the responsivity G or the effective spring constant k (gain shifts). These effects are often due to temperature changes in mechanical or electronic components or to parasitic spring or friction forces, and must be carefully controlled in the design. Various methods to control or correct for drift and minimize parasitic forces are discussed below. The residual variability in the response must be characterized by repeated calibration measurements under different conditions to determine its contribution to the error estimate, which is discussed in Section VI.

3. Accuracy.

Accuracy is a measure of the error between a thrust stand measurement and the true value of the thrust. In addition to being precise, which is ensured if the thrust stand is sufficiently sensitive, repeatable and not subject to large random errors, it must produce accurate results. High accuracy in a precise thrust measurement is achieved by minimizing systematic errors, and can only be demonstrated by calibration measurements of known forces or impulses. To properly demonstrate that a thrust stand meets a given accuracy requirement, the calibration method must be carefully designed so that it reproduces the conditions of the actual thrust measurement and does not introduce additional systematic errors.

4. Resolution.

Resolution is defined as the smallest difference between two thrust or impulse inputs that can be reliably distinguished in the thrust stand response. The resolution is ultimately limited by the noise level of the stand’s response, so achieving high resolution depends on minimizing noise. Sources of noise typically include the electrical noise associated with sensors, mechanical noise due to vibrations in the environment that are transmitted to the thrust stand, and, on long time scales, variations in thrust stand response that may be caused by periodic changes in temperature, for instance. Thrust stand resolution can be quantified by varying the difference between two input loads until the responses become indistinguishable [5]. In practice this approach may not be feasible, and resolution is often inferred from measured noise levels.

In some cases, the frequency-dependent thrust noise level generated by the thruster is an important measurement parameter. For instance, the thrusters for the ST7/LISA Pathfinder mission had to demonstrate a thrust noise level <0.1μN/Hz for frequencies between 1 mHz and 4 Hz, a requirement driven by the control algorithm for the disturbance reduction system [6]. In addition to having adequate frequency response, as discussed above, the thrust stand must have a noise floor (noise in the response with no thrust load) significantly lower than the requirement the thruster must meet. The noise floor can be characterized either by amplitude vs frequency or by the power spectral density. This may also be considered the frequency-dependent resolution of the thrust stand. Figure (5) shows an example noise spectrum for the thrust stand described in section III D.

Fig. 5.

Fig. 5

Example noise spectrum measured on the torsional pendulum shown in Fig. (9). This noise floor defines the frequency-dependent resolution of the thrust stand.

5. Response Time.

The thrust stand response time is an important metric for time-resolved measurements, and can be characterized by a number of parameters. Quantitative metrics based on a step input include the rise time (time required to reach 100% of the steady-state value), the peak time (time required to reach the peak response), the maximum overshoot, and the settling time ts (the time required for the variations around the steady-state value to drop to within 2% of that value). Figures (2) and (3) illustrate the effect of damping ratio on these parameters. A damping ratio of 0.4 ≤ ζ ≤ 0.8 generally gives good step response. For this range, ts = 4/ζωn.

6. Predictability of the Response.

The response of an ideal pendulum is linear in the small angle approximation presented in Section IIB. A pendulum thrust stand need not have a linear response, depending on the characteristics of the spring, damper, and position sensor components, but it is good practice to design the stand so this is the case. At a minimum, the transfer function must be known so that sensitivity calibration data can be interpreted in terms of a physical model. Deviations from the known linear (or nonlinear) functional form measured in a calibration can be used to estimate the contribution of the calibration process to the overall error or to identify systematic problems that need to be resolved before proceeding with a thrust measurement.

Transfer function complexity often depends primarily on the behavior of damping elements in the thrust stand. Active electronic spring/damper systems can be designed to provide a force that is proportional to the deflection or the velocity of the pendulum, or to the integral of the deflection (proportional/integral/derivative or PID control), which results in a much more complex transfer function compared to passive linear elements such as eddy current or viscous dampers. Active control can provide improved transient response, but at the price of greater complexity of the measurement system and analysis.

In addition to these quantitative performance metrics, other considerations such as ease of use and compatibility with calibration methods play a role in thrust stand design.

III. Thrust Stand Configurations and Components

All three basic pendulum configurations have been successfully employed with electric thrusters and each has its own advantages and challenges. In this section we review the unique features of each approach and discuss example designs that have provided excellent performance for their applications. First, however, we describe options for components that are common to all thrust stand configurations.

A. Components Common to All Pendulum Thrust Stands

All pendulum thrust stands require displacement sensors and spring elements and most incorporate dampers. Displacement sensors are a key element in meeting performance requirements. They are typically non-contact devices to prevent hysteresis from mechanical drag and have a range and resolution chosen to match the thrust stand design deflection. Sensors that have been used successfully on thrust stands include Linear Variable Differential Transformers (LVDTs, also known as Linear Variable Differential Transducers) [2, 710], capacitive sensors [11], optical interferometers [5, 12, 13], reflectance fiber optic sensors [14], autocollimators [15], laser triangulation systems [16], and photoelectric position sensors [17]. In this section we review LVDTs and laser interferometers, two sensor options that bracket the measurement range and resolution required for electric propulsion thrust stands.

A recommended option for thrust stand designs with relatively large deflections (on the order of a mm) is the LVDT, which consists of two components. The transformer, which is typically mounted on the fixed part of the thrust stand, is a tube with three solenoidal windings spaced along the axis. The primary is in the center and two secondaries wound in opposite directions are located symmetrically on either side of the primary. A cylindrical ferromagnetic core attached to the pendulum moves freely along the fixed transformer axis. The primary is driven with an AC current, which induces a voltage in each secondary winding that depends on the location of the core. The difference between the two secondary winding signals is a sensitive measure of the core’s position. Commercial LVDTs typically have a response that is linear to within 0.25–0.5% of full scale (FS) within the specified range, which can be < 1 mm to as high as 500 mm. LVDTs are extremely stable with a temperature sensitivity on the order of 0.02% FS per degree C and a repeatability on the order of .01% FS. The analog signal offers unlimited spatial resolution in principle. In practice it is limited by electrical noise, but sub-micron resolution is achievable [8]. The sensors (particularly AC LVDTs, which do not have electronics integrated with the transformer housing) are relatively immune to electrical noise from thrusters.

Optical interferometers offer much higher sensitivity and resolution and have been used successfully on thrust stands with very small deflections [5, 12, 13] although they are a more expensive solution. In a basic interferometer, a coherent light beam is split into two beams using a beam splitter. The beams are directed along different paths and then recombined. If the path lengths are different by a non-integer multiple of the wavelength, the beams will have different phases and will interfere either constructively or destructively. The amplitude of the combined light signal will therefore vary periodically as the path length changes. By reflecting one beam from the movable pendulum and the other from the fixed base of the thrust stand and then recombining them, changes in the relative displacement can be calculated from the time-dependent, periodic amplitude of the combined signal measured with one or more photodiodes. Cubbin developed a Michelson interferometer [18] with a range of tens of microns and a resolution based on measured noise of 10 nm [12]. The Nanobalance described in Section IIIC [5, 13] employs a high resolution Fabry-Pérot interferometer [18]. The measurement range is on the order of 150 nm (for a 1 mN full scale thrust level) and the frequency resolution of the cavity corresponds to a spatial resolution of 14 pm. The phase [12] or frequency [13] measurement with interferometers is linearly related to the displacement. The photodiodes used in these systems proved to be immune to electrical noise from the thrusters.

To damp thrust stand oscillations, passive eddy current dampers [17, 1924] and active electromagnetic dampers [7, 25, 26] have primarily been employed, although oil dampers have also been used [9, 10]. Eddy current dampers are simple, non-contact mechanisms consisting of two stationary magnets between which a conducting plate (typically copper) moves. The magnetic field induces eddy currents in the plate which interact with the magnetic field to generate a Lorentz force proportional to velocity that opposes the motion. Active electromagnetic force actuators consist of a ferromagnetic core which moves along the axis of a solenoid. The force on the core is proportional to the current in the solenoid. A closed-loop PID controller is often used to vary the solenoid current to damp out time-dependent components of the thrust stand motion. Active dampers provide more flexibility in tuning and can be turned off to observe the free motion of the thrust stand (for impulse measurements, for example).

The spring elements of a thrust stand consist of the pendulum pivot, any springs deliberately added to increase or fine-tune the spring force, and wires or tubing that cross between moving and stationary parts of the thrust stand, producing parasitic spring forces. Pendulum pivots can consist of simple flat plate flexures [25, 26] or more complex flexural pivots [8, 9, 14, 16, 23], which are commercially available. Beams resting on knife edges are sometimes used as the pivot points for hanging pendulums to minimize the restoring force [27]. Some torsional thrust stand variants use thin beryllium [22] or tungsten [15, 28] wire to support the weight of the beam. The wire diameters are typically on the order of 0.5 mm [15] and the torsion spring constant of the wire provides the restoring force. However, flexural pivots allow a higher beam system mass (including thruster and counterweights).

Electrical conductors, propellant and cooling water tubing, and instrumentation wiring that cross the interface between the facility and the movable pendulum also contribute to the effective spring constant. These components must be carefully chosen to provide repeatable behavior. While finely-stranded braided conductors may minimize reaction forces imparted through the thrust stand, internal friction during flexure often results in non-repeatable tares, and unacceptable levels of uncertainty in thrust measurements. Similarly, soft polymer tubing often exhibits viscoelastic behavior that varies significantly with temperature. Solid metal tubing should be used to maximize linearity and repeatability. Novel approaches to minimizing the spring force from these elements include the use of liquid gallium pots to transfer electric power [19, 20, 45] and an oil seal in the gas feed line on the axis of a torsional pendulum [9, 10]. The oil pot also served as a viscous damper in this design.

B. Inverted Pendulum Thrust Stands

Inverted pendulum thrust stands have two main advantages-they can achieve high sensitivity and are very compact. In its simplest form, an inverted pendulum consists of a vertical arm attached to a bottom pivot or flexure with the thruster mounted at the top. With an inverted pendulum configuration, the torque produced by the thruster weight counters the spring torque and reduces the effective spring constant, as shown in Eqn. (6). By carefully balancing the length of the pendulum and the thruster mass with the spring stiffness so that the gravity torque approaches the spring torque, very large deflections in proportion to applied thrust can be obtained. Deflections of several millimeters are commonly achieved with pendulum lengths less than 20 cm, permitting use in vacuum chambers less than 1 m in diameter [29].

However, these characteristics lead to several challenges. Inverted pendulum thrust stands are very sensitive to changes in the inclination of the stand with respect to the gravity vector. The thrust stand deflection when the z-axis is parallel to the gravity vector, as shown in the idealized configuration in Fig. (1), is given by Eqn. (8). However, if the thrust stand is tilted by an angle θZ, defined in Fig. (6), an additional term appears:

θss=FtLtk+θz(ksmgLcm1). (16)

Fig. 6.

Fig. 6

In actual thrust stands the z-axis may be tilted with respect to the gravity vector. Changes in the angle θz will change the sensitivity of the stand.

Inverted pendulum thrust stands yield large deflections for a given force Ft when mgLcm is comparable to ks. But this can also make the second term in Eqn. (16) large, so θz must be constant for the thrust stand response to be repeatable. Most inverted pendulum thrust stands therefore incorporate active control of the inclination. Counterweights can also be used to move the center of mass closer to the pivot point, which eliminates this effect [30]. However, it also eliminates the advantages of using the gravity torque to improve sensitivity and generally results in larger thrust stands.

Compact inverted pendulum thrust stands are also particularly vulnerable to heat absorbed from the thruster, which can alter the spring constant and cause zero and gain shifts. Thermal shrouds and active cooling of critical thrust stand components are essential to minimize thermally induced drift in thrust measurements. Finally, as in all pendulum thrust stands, the sensitivity is dependent on the stiffness of all components of the thrust stand, including electrical leads and propellant tubing necessary for thruster operation. Care must be taken in the mechanical design to ensure that the stiffness of these components does not change during operation.

1. Mechanical Design

Inverted pendulum thrust stands can be built with a single linkage like the idealized schematic in Fig. (1) [25]. However, most inverted pendulum thrust stands use parallel linkages to keep the thruster oriented horizontally throughout their range of motion [26, 2934]. All movement of the thrust stand is mechanically blocked except for straight-line deflection parallel to the thrust vector, which yields a number of advantages. Significant rotation of the electric thruster is undesirable where plume diagnostics take place simultaneously with thrust measurement. In addition, the thruster center-of-mass can be positioned anywhere on the movable upper platform without significant impact on measurement accuracy. Finally, magnetic coupling between the electric thruster and the earth’s magnetic field should not result in significant moments about the pendulum arm. These advantages come at the cost of additional complexity. A parallel linkage thrust stand has roughly four times as many moving parts and joints when compared to a simple inverted pendulum configuration. The additional joints increase the spring stiffness of the thrust stand, requiring additional pendulum height or mass to match the sensitivity of a single-linkage stand.

An example of an inverted pendulum thrust stand developed at the NASA Glenn Research Center is shown in Figure (7) [26]. Parallel linkages (side plates with flexures connecting the upper movable platform to the fixed bottom plate) share the vertical load and maintain the top plate in a horizontal orientation. Many electric thrusters have thrust-to-weight ratios less than 1/500. Consequently, the arm of the thrust stand is primarily stressed in compression, supporting the thruster weight. While it is desirable to have highly flexible pivots in the pendulum, they must be stiff enough to avoid buckling under the weight of the thruster and resist handling loads during installation. Fixed mechanical stops are provided to limit thrust stand deflection and prevent accidental collapse. For high sensitivity, the pendulum arm should be long enough to yield a gravity torque for a given mounted weight that approaches the spring torque. To remain stable, however, the gravity torque must not exceed the spring torque. In practice, the thrust stand sensitivity is generally fine-tuned by adding ballast to the upper platform or an auxiliary spring to increase the effective spring constant.

Fig. 7.

Fig. 7

Example of a state-of-the-art inverted pendulum thrust stand [26].

Up to 5 mm of displacement is measured with an LVDT. The displacement signal is processed by a PID controller, which drives an electromagnetic actuator coil to damp high frequency motion. The damper signal is carefully balanced to ensure that it contains no DC bias. The low frequency portion of the LVDT output is recorded as the thrust signal. Alternatively, the thrust stand can operate in null mode, described in detail in Section III E. In this configuration the PID controller uses the low frequency LVDT output to drive current to a second water-cooled null coil, which holds the thrust stand at a given set-point. The null coil current serves as the thrust signal.

A high sensitivity gravitational inclinometer (“tilt sensor”) mounted on the bottom plate monitors thrust stand inclination changes, which are often caused by facility distortions during pump down or thermal distortions during operation. The inclination is automatically corrected by raising or lowering the rear of the thrust stand relative to a pivot point near the front using an actuator (typically a motor-driven screw) located at the end of a long pivot arm. The thruster is thermally isolated from the thrust stand by a water-cooled mounting post. The entire thrust stand is contained within a temperature-regulated water-cooled enclosure (not shown), except where the cooled mounting post protrudes. Thrust stands of this type have been used to test thrusters ranging from 100 kW Hall engines with mass in excess of 100 kg [31] down to 300W Hall thrusters with a mass of 0.9 kg [29].

2. Thrust Stand Performance

One advantage of inverted pendulum thrust stands is that the sensitivity can be easily tuned by adding or removing ballast or changing the auxiliary spring. Vibration transmitted to the thrust stand from the facility is generally the dominant disturbance that limits thrust stand resolution. Vibrations can be attenuated by isolating the thrust stand and by choosing a natural frequency much less than the frequency of vibrations. Full-scale deflection is often chosen to be at least two orders of magnitude larger than expected vibrational noise within the vacuum facility. Assuming a noise amplitude of 0.025 mm, a full scale deflection choice of 2.5 mm would result in 1% noise.

For angles less than 5°, inverted pendulum thrust stand deflection is assumed to be linearly proportional to applied thrust (Eqn. 5). Measurement error due to nonlinearity is usually much less than other errors introduced by zero drift and vibration. End-to-end calibration, from thrust stand to data recorder, is easily performed by applying known loads to the pendulum, as described in Section IV. Another advantage of parallel linkages in inverted pendulums is that the calibration force can be applied at any point on the rigid platform on which the thruster is mounted. With a single pendulum arm, the calibration forces must either be applied at the same distance from the pivot as the thrust forces, or the location of the calibration forces relative to the thrust forces must be known accurately to scale the resulting torques.

Long term drift in thrust stand response is generally due to thermal effects or changes in the stiffness of parasitic spring elements. Both can be controlled with careful thermal design and choice of materials. Sections IV and V discuss methods for managing drift in calibrations and measurements.

Thrust stand sensitivity, noise, and response time are related through the pendulum dynamics reviewed in Section IIB. One way of expressing sensitivity based on the equations above is as the maximum linear deflection xFS in response to full-scale thrust Ft, measured at the distance of load application from the pivot Lt, or

xFST=Lt2k (17)

Assuming that the moment of inertia is ILt2Mt, where Mt is the thruster mass, the natural frequency can be expressed as

ωn=kLt2Mt=(Ft/W)gxFS, (18)

where W = Mtg is the weight of the thruster. The thrust-to-weight ratio (Ft/W) of electric thrusters is usually much less than 1. For arcjet thrusters (Ft/W) is typically 1/200, for Hall thrusters (Ft/W) is typically 1/300, and for gridded ion thrusters (Ft/W) is typically 1/600 [29, 35]. The characteristic response time for a critically damped thrust stand to settle is approximately one period,

τn=2π/ωn=2πxFS(Ft/W)g. (19)

If a Hall thruster were to be tested that had a thrust-to-weight ratio of 1/300 the expected settling time would be approximately 1.7 seconds. The actual natural period will be somewhat longer than this, due to the additional mass for the thrust stand top-plate, mounting brackets, tubing and electrical cables. A response time of several seconds is usually adequate for most performance tests, where thermal equilibrium of the thruster may not be reached for many minutes. If necessary, response time can be improved by selecting a smaller full scale deflection xFS, assuming vibration noise levels are acceptable.

Properly designed inverted pendulum thrust stands like that shown in Fig. (7) have demonstrated excellent performance over a range of thrust levels. For example, thrust levels ranging from 5 mN to 20 mN were measured for a 0.3 kW Hall thruster with an estimated uncertainty of ±1.5% [29]. Thrust levels up to 2.3 N were measured for a 50 kW Hall thruster with an uncertainty estimated to be ±2% [36].

C. Hanging Pendulum Balances

Thrust stands based on hanging pendulums are conceptually simple and easy to use in principle. In their simplest form, conventional hanging pendulums consist of a vertical arm attached to a top pivot or flexure and a thruster mount or platform at the bottom. They are inherently stable because the gravity torque always acts to restore the pendulum to the null position. In fact, gravity is generally the dominant restoring force, so they have proven to be the least susceptible to zero drift caused by changes in flexure stiffness. However, because electric thrusters have low thrust-to-weight ratios, the deflections of hanging pendulum thrust stands are often very small, which can complicate their design and use.

1. Mechanical Design

The primary challenge in mechanical design is to achieve deflections for the expected thrust range that are measurable with adequate resolution. Because the effective spring constant in hanging pendulum stands is generally dominated by the weight term (Eqn. 6), the main design approach to increasing sensitivity is to lengthen the pendulum arm, as is apparent in Eqn. 14. Therefore, more sensitive stands typically require large diameter vacuum facilities. Mechanical linkages that magnify the deflection of the arm and counterweights have also been employed to improve sensitivity [19]. Alternatively, sensors such as laser interferometers that are capable of measuring small deflections with high resolution are used [5, 13]. In this case vibration isolation or compensation, active inclination control, and careful thermal design are required to minimize these disturbances to the small thrust signal.

An example of a state-of-the-art hanging pendulum thrust stand is the Nanobalance, shown schematically in Fig. (8), which was developed for microthruster applications by Thales Alenia Space Italia in co-operation with the Italian National Metrology Institute and Polytechnic of Turin [5, 13]. This stand consists of two BeCu plates that hang from BeCu flexures attached to a rigid block of Zerodur©, a material with a very low coefficient of thermal expansion. The microthruster to be tested is mounted on one of the plates and an identical dummy mass on the other. Both plates are assumed to have the same dynamical behavior, so they respond in the same way to common-mode vibrations from the environment. The displacement of one plate relative to the other is then measured as a thrust response that is free of environmental vibrations. Extensive vibration isolation on the stand and the vacuum facility is also used to minimize disturbance inputs. Two spherical mirrors mounted on the plates form an optical cavity for a Fabry-Perot laser interferometer, allowing very sensitive measurements of the relative displacement (described briefly in Section III A). Two calibrated actuators (voice coils) that produce a variable force on a permanent magnet by the field from an electromagnet are used to calibrate each of the pendulums in situ. The force produced by these actuators was independently measured [13].

Fig. 8.

Fig. 8

Example of a state-of-the-art hanging pendulum thrust stand [13].

Like all pendulum thrust stands, this one is subject to zero drifts caused by changes in the inclination of the mount from which the pendulum plates hang and thermal effects. The Nanobalance incorporates piezoactuators that level the stand based on feedback from an inclinometer mounted on the Zerodur frame. Temperature control and careful choice of materials were used to minimize thermal drift and residual drifts in the signal were corrected with polynomial fits to the measured temperature [13].

2. Thrust Stand Performance

Using these techniques allows hanging pendulum thrust stands to achieve very high performance. For example, the Nanobalance has demonstrated a linear response (in terms of frequency shift measured with the Fabry-Perot interferometer) over thrust levels up to 1 mN. The thrust stand sensitivity in terms of deflection for a given force was only 140 pm/μN, but a resolution of 0.1 μN was enabled by the high spatial resolution of the interferometer. The measurement accuracy was 0.65 μN (based on random noise characterized over a period of 10000 s) + 1% of reading. A noise floor spectral density of <0.1μN/Hz between 0.1 and 1 Hz (and <1μN/Hz down to 1 mHz) was measured [13]. Larger hanging pendulum thrust stands have demonstrated performance similar to inverted pendulum stands for thrust levels up to several N [19].

D. Torsional Pendulum Thrust Stands

Unlike both the hanging and inverted pendulum thrust stand configurations, an ideal torsional pendulum’s rotational axis is parallel to the gravity vector, making its response independent of thruster mass. Torsional pendulum thrust stands, also called torsion balances, are well-suited for thrusters that are either changing in mass or for testing in facilities that must accommodate a very large range of thruster weights. Torsion balances have shown very high sensitivity, making them particularly useful for micropropulsion applications. Torsional thrust stands are inherently more stable than inverted pendulum thrust stands [7] and offer a balance between high thrust measurement sensitivity and low environmental noise sensitivity [19, 37].

Because low-thrust measurements require long beams, torsional thrust stands may be difficult to accommodate in smaller vacuum chambers. This is especially true for the optimal symmetric arm configuration. While asymmetric configurations are possible (such as a “swinging-gate” configuration [12]), this approach can lead to induced coupling modes excited by facility vibrations. Gravity can affect measurements under two conditions: 1) when the vertical rotation axis is offset from the gravity vector and 2) when the center of mass does not lie on the vertical rotation axis. In the first case, when the offset angle is positive, the system is stable because the torque works with the spring as a restoring force. As the offset angle grows more negative, the torque will resist the spring force and, at large enough negative angles, lead to instability. Two design variables can be adjusted to reduce the magnitude of gravity torques [8]: the distance of the center of mass from the rotation axis and the offset angle. It is generally easiest to change the distance of the center of mass from the rotation axis. Counterweights are often used on the side of the beam opposite the thruster to place the center of mass of the beam system very near the axis of rotation [8, 9, 1416, 24, 28].

Torsional thrust stands can resolve thrust levels from hundreds of nN to a few N [16, 22, 23, 28], spanning a large range of thrusters such as Field Emission Electric Propulsion (FEEP), Pulsed Plasma Thrusters (PPTs), gridded ion thrusters, and Hall thrusters.

1. Mechanical Design

Figure (9) shows a typical torsional thrust stand design [8]. Torsional thrust stands utilize a long beam attached at two flexural pivots where torsion springs provide a restoring torque, ideally parallel to the gravity vector. Thrust measurements are obtained by determining the angular deflection of the beam. The linear displacement x(t) ~ Lpmθ(t) at a specified position along the beam Lpm is measured. In this example, deflections of up to a few mm are measured with an LVDT. An electromagnetic damper provides active damping using a PID controller. Two motor-driven screws on orthogonal arms provide active leveling to compensate for shifts in the thrust stand base that occur during facility pump down.

Fig. 9.

Fig. 9

Example of a state-of-the-art torsional pendulum thrust stand [8].

2. Thrust Stand Performance

Torsional thrust stand sensitivity depends on a number of design choices, including torsion spring constant, length of thrust stand beam, and measurement distance from the axis of rotation. As in the thrust stands described above, the angular deflections are generally limited to less than about 5 degrees so that the measured displacement can be linearly related to thrust. Typical thrust stand resolution is better than 1 μN for steady-state forces and less than 1 μN-s for impulse measurements [8]. Even higher resolution-less than 0.03 μN-has been reported [14]. Yang et al. report resolutions of 0.47 μN-s for impulse bits up to 1,350 μN-s and 0.09 μN for steady-state thrust values up to 264 μN [15]. Several torsional thrust stands have demonstrated frequency-dependent noise floors that meet the demanding requirements of the ST7/LISA Pathfinder mission (see Fig. (5), for example, which displays the noise floor measured with the thrust stand shown in Fig. (9) [8]). Overall thrust stand accuracies of ± 0.5 μN for steady-state thrust levels from 1 to 100 μN [8] and impulse accuracies of 2.1 μN-s for an impulse range of 20–80 μN-s and 0.7 μN-s for an impulse range of 1–10 μN-s [2] have been measured.

E. Steady-State Null Balances

The goal of steady-state thrust measurement is to determine an unknown force in a laboratory environment and also track slowly developing variations in that force. A steady-state null balance accomplishes this by applying a control force to cancel thrust stand deflection caused by the unknown force [15, 26, 30]. When the deflection has been nullified to zero, the control force is assumed to equal the unknown force.

Conventional thrust stands based on spring-mass systems must be carefully sized so that the load spring is capable of absorbing the maximum expected force. However, an excessively stiff load spring could result in reduced force measurement resolution. With a null balance, the control force absorbs all of the unknown force, and system spring constant is much less critical. In addition, conventional thrust stands based on spring-mass systems by necessity allow the thruster to move. The exact position and pointing of the thruster within the test facility is not well-controlled, which may complicate other diagnostics such as plume or thrust vector measurements. With a null balance, thruster position is strictly determined by the system set point, except during brief thrust transients.

The mechanical configuration of null balance thrust stands can be very similar to spring-mass type thrust stands. Other than the addition of a force actuator, both stands have many of the same components, including a position sensor. However, the overall system design of a null balance is very different. While spring-mass thrust balances typically operate open-loop, a null balance uses a tuned feedback loop for stable operation. A PID control system is generally implemented in software [30] or hardware [15, 26] to regulate the actuator control force. The null balance control system must keep the position sensor at the exact set location under steady test conditions. Precise knowledge of the control force is necessary, since this is assumed to equal the unknown force to be measured. Electromagnetic actuators similar to those used as active dampers are typically employed and the solenoid current is sensed as a measure of actuator force. Active cooling of the force actuator may be required at higher thrust levels because of heat generated in the coil. Null balances are calibrated in the same way as conventional thrust stands, as described in the next section.

IV. Calibration

Calibration serves three primary purposes. First, the calibration process produces the relationship between deflection or sensor output and thrust or impulse. Second, the accuracy, precision, and repeatability of a thrust stand are determined by repeated application of known forces or impulses, so it is an integral part of the error quantification. Finally, comparison of measured response with the expected theoretical response can reveal systematic problems that would bias the measurements if uncorrected.

A. Application of a Known Force

Laboratory testing of an electric thruster often requires complex interfaces between the thruster and the test facility. Electric current, instrumentation, and various propellants must be provided to the thruster through these interfaces, all of which contribute elastic stiffness and affect the static equilibrium. While these contributions could be characterized individually and summed to calculate the total effective spring constants that determine thrust stand sensitivity [15], it is much more practical to perform an end-to-end calibration of the entire thrust stand installation, where all dynamic and static forces are characterized simultaneously. The calibration process is typically performed with the entire installation fully prepared to test, under vacuum, and only minutes before start-up of the electric thruster. Calibration involves applying known forces Fcal at a point Lcal from the pivot and monitoring the change in position at Lpm to determine the thrust stand sensitivity,

Scal=ΔxssFcal=LpmLcalIωn2. (20)

To calculate the steady-state thrust of a thruster from a measured displacement Δxss, this sensitivity must be scaled by the difference in distances from the pivot at which the calibration and thrust forces are applied:

Ft=(Lcal/Lt)ScalΔxss. (21)

The uncertainty in the ratio Lcal/Lt must be included in the total thrust uncertainty estimate. If the calibration forces are applied in the same location as the thrust forces, the ratio Lcal/Lt = 1 and the thrust force can be determined directly from the calibration curve for a given Δxss measurement. The sensitivity of null balance thrust stands is calibrated by measuring the force actuator coil current, rather than pendulum displacement, as a function of applied force.

Calibration forces can be applied in a number of ways. One common approach is to load and unload weights with known masses on a flexible fiber that passes over a pulley and attaches to the pendulum, as illustrated in Fig. (10). The fiber must be carefully aligned with the thrust vector, and the pulley must be designed with minimum static and dynamic friction so that it transmits all of the force from the weights to the stand. An advantage of null balances is that they are unaffected by dynamic friction. An example of the thrust stand response to this kind of calibration is plotted in Fig. (11). These data were obtained with an inverted pendulum thrust stand similar to that shown in Fig. (7). In this case four calibration weights were hung from a fine chain that passed over a pulley and attached to the rear of the moveable upper platform. The other end of the chain was attached to a cylinder mounted behind the pulley that could be turned with a small DC motor to raise the weights on the cylinder-side of the chain loop, removing the force from the thrust stand. The position of the take-up cylinder was measured with a potentiometer. The change in the LVDT signal, which is proportional to the thrust stand displacement, with application of one, two, three and all four weights was measured. The position of the balance is sensitive to the inclination of the base, so this was measured with an inclinometer and actively controlled using a DC motor-driven screw to raise or lower one end of a cantilever beam on which the thrust stand was mounted. The inclinometer output voltage was used as the feedback signal to a software proportional controller that controlled the motor. Application of the weights caused small shifts in the inclination, as shown by the inclinometer signal in Fig. (11), which were then corrected by the controller.

Fig. 10.

Fig. 10

A common calibration system that applies forces by loading and unloading weights with known masses [30].

Fig. 11.

Fig. 11

Thrust stand response to application of known forces.

As in this example, the force from the calibration weights is often stepped up and down incrementally using a remotely operated mechanism. The transducer signal is measured after applying weights and after removing them (the thrust stand zero), as shown by the solid circles in Fig. (11). These measurements are often averaged over a number of samples to obtain a good estimate of the mean value, particularly if the transducer signal is noisy. The thrust stand response is defined as the difference between the signal with weights and the zero measured immediately afterwards. This approach automatically corrects for any drift in the thrust stand zero. The calibration process should be designed so that the calibration weights span the range of expected thrust values and are evenly distributed across the range.

Figure (12) shows an example of a calibration curve constructed from n = 40 observations of thrust stand response for given input forces similar to those plotted in Fig. (11). The response is modeled as a linear function of the applied forces,

xi=β+SFi+ui, (22)

where the xi are the measured responses to input forces Fi, S in this case corresponds to the sensitivity of the balance, and the ui are random disturbances. A finite force has to be applied to overcome static friction, so a plot of deflection vs. force will typically exhibit a negative intercept. If the linear fit to the data is forced to go through zero, it will introduce additional error. The intercept β should be estimated from the data. The disturbances are assumed to be normally distributed with a mean of zero and a common variance of σx2. The input forces are assumed to be known without error, so the calibration method must be designed so that the uncertainty of the input loads is much less than that of the stand response. Standard analysis packages can then be used to perform least squares analysis to determine b and Scal, estimates of β and S that minimize the sum of squared residuals:

i=1nui2=i=1n(xiβSFi)2. (23)

Fig. 12.

Fig. 12

Calibration data relating thrust stand deflection in terms of LVDT sensor output to applied force with linear fit and standardized residuals.

These regression parameters then yield predicted values of the response for given inputs,

x^i=b+ScalFi. (24)

The calibration data can be used to calculate an unbiased estimate of the variance σx2 of the random disturbances,

σx2sx2=i=1n(xibScalFi)2n2. (25)

The standard deviation sx is a way to characterize the variability in response with fixed input and plays a key role in the error estimate, discussed in more detail in Section VI. The standardized residuals, ei/sx=(x^ixi)/sx are also plotted in Fig. (12). Residual plots are a very powerful way to evaluate the quality of a fit [38]. In general, if the assumed model is correct, the standardized residuals will fall uniformly between −2 and +2 and will be randomly distributed around zero. A systematic pattern of variation in the residuals can indicate a deviation from linear behavior or other violations of the assumptions on which least squares analysis rely. Another parameter often used in evaluating fits is the square of the correlation coefficient,

R2=1(xix^i)2(xix¯)2 (26)

where x¯ is the mean of the measured responses. This is a measure of the proportion of total variability in the xi that can be explained by the Fi. However, it is only a measure of correlation and a high value does not mean that the data have been well-fit, or that the calibration curve will yield results with low uncertainty [38]. To illustrate this, Anscombe [39] generated four hypothetical data sets, each yielding the same summary statistics for a linear least squares fit (including the same value for R2). However, three of the four data sets are clearly not well-represented by the linear fit, deviating from the linear model due to different pathologies. Careful examination of the residuals can help avoid these pitfalls and is recommended for high quality thrust measurements. For example, a lack of linearity or repeatability apparent in the residuals typically indicates a mechanical problem with the thrust stand installation, such as dragging or unintentional contact with something as the thrust stand deflects, which should be corrected prior to making thrust measurements.

B. Application of a Known Impulse

Pendulum thrust stands can also be used to make impulsive measurements but must be calibrated to characterize the response over the appropriate range of impulse bits. Thrust stands used in impulse measurements are typically underdamped pendulums which are allowed to oscillate at their natural frequency after an impulse perturbation. Hanging or inverted pendulums can be used but torsional balances offer improved sensitivity. Because the free response of the thrust stand to the impulse is measured, these are not null balances. Active electromagnetic dampers may be used to reduce vibrations from the facility, but they are turned off prior to making impulse measurements [2, 7].

Although thrust stand parameters such as effective spring constant and natural frequency or moment of inertia can be measured to calculate the sensitivity [7, 15], calibration is usually accomplished by applying known impulses Ibit,cal at a point Lcal from the pivot and inferring the sensitivity from a change in the dynamic response of the swinging arm (such as initial velocity, peak amplitude, or full range of motion), similar to the method outlined above for thrust measurements. For example,

Scal=Δx˙(0)Ibit,cal=LpmLcalI, (27)

assuming an impulsive force at t = 0. As in thrust measurements, this sensitivity must be scaled by the difference in distances from the pivot at which the calibration and thrust forces are applied to calculate the impulse from a measured change in velocity Δx˙(0), for instance:

Ibit=(Lcal/Lt)ScalΔx˙(0). (28)

Typical calibration methods can be broken down into either contact or non-contact methods. Several contact calibration methods involve the swinging of known masses [4, 40] or the use of impact pendulums [2] or impact hammers [8]. Non-contact methods include calibration using electrostatic forces between planar electrodes [14], free molecular gas flow from underexpanded orifices [9], electrostatic combs [24], and electromagnetic coils [17]. Of these methods we recommend piezoelectric impact hammers and electrostatic combs, which are common practice and provide precise, controllable impulses over a broad range.

Electrostatic combs (ESCs) or fins are known for their versatility as they can provide both a steady-state force as well as a wide range of impulses. ESCs consists of a set of interlocking non-contacting combs separated by a small gap. One set of the pair is placed on the moving part of the stand (usually the grounded set) and the other is mounted on the fixed part of the stand and aligned with the moving combs. The attractive force provided by the combs is a function of the applied voltage, the geometry, and the number of comb pairs in a set [42]. Unlike electrostatic actuators using planar electrodes [14], this comb geometry is independent of the gap, or engagement distance between the combs. This has two major implications for impulse balance calibration. First, it does not require that the location of the stand, and therefore the engagement distance, be known with great accuracy. Second, even though the engagement distance is changing slightly as the stand oscillates, the force applied by the combs does not change throughout the stand’s motion.

By accurately controlling the amount of charge, or voltage, on the combs as well as the time that the charge is applied, a well-known impulse can be created. ESCs can accurately produce forces from 10s of nN [41] to 10s of mN [24] with errors typically less than 1%. By varying the pulse width and amplitude of the applied voltage, Pancotti demonstrated impulses ranging from 0.01 mN-s to 20 mN-s which produced responses of a torsional thrust balance that were linear to within 0.52% [24]. The capacitance of the combs may lead to voltage overshoot at the beginning of the pulse. While this might not be an issue for longer pulse times, voltage overshoot from very short pulses may induce errors [24]. It is important therefore to understand the RLC characteristics of the pulse-forming system and design the circuit to minimize overshoot.

As with any calibration system the calibration mechanism itself must be well calibrated so that the uncertainty in the applied impulses is very low, a key assumption of the linear least squares analysis. The force generated by electrostatic combs as a function of applied voltage is typically measured by mounting the comb assembly on a micro-balance scale which has been calibrated with NIST-traceable standards. The impulse delivered by a pulsed comb system is calculated by integrating the force over the pulse width.

Piezoelectric impactors are commercially available in a variety of shapes and sizes, and are generally pre-calibrated. The typical procedure for impulse balance calibration is to strike the stand with the force transducer while recording the output voltage from the transducer. This output voltage is calibrated to correspond to a force, and integrating over time yields a total impulse. The force transducer can be mounted on a swinging pendulum arm that, when released, will strike the stand. The magnitude of impulses applied in this manner can be varied by adjusting the pendulum release height and the striking material. Typically the cocked angle and the release trigger are controlled by an electromagnetic actuator [8]. Forces ranging from 0.5 N to 100 N with errors of ± 2% can be achieved with this method [43]. Calibration hammers can also be driven with a servo motor, which can provide very accurate control of position and velocity and improve the accuracy of the applied impulse. Servo-controlled swing arms have been used to produce impulses ranging from 10 mN-s to 750 mN-s and generated a thrust stand response that was linear to within 0.5% over that range [24].

For piezoelectric hammers, a proper calibration should be performed either by the manufacturer or preferably in-house under the conditions the force transducer will be used. To calibrate a force transducer, a free suspended reference mass with an attached accelerometer can be used [24]. Beyond the calibration itself, other factors including strike location and digitization and integration all have to be carefully conducted in order to properly track errors and determine the total accuracy of the impulse calibration system.

The known calibration impulse will perturb the natural motion of the stand and cause it to ring or oscillate at its natural frequency. Figure (14) shows a plot of LVDT voltage as a function of time for a torsional balance that has experienced an impulsive perturbation. The impulse caused the stand to deflect with an initial velocity Δx˙(0) and a maximum range of travel, defined as the difference between the first peak and the first valley in the oscillatory response. These parameters can be estimated by fitting a damped sinusoid (for underdamped pendulums) to the data. The analysis of linear fits outlined above can be extended to nonlinear fits such as this. In practice, there is often a small amount of background motion or drift that must be subtracted to determine the change in motion due to the impulse. In this case, a damped sinusoid is also fit to the position history before the impulse and the response is defined as the difference between that and the motion after the impulse [8]. In a careful study of the variance associated with various fitting approaches, Koizumi et al. [2] found that the noise was predominantly at the natural frequency of the stand and could be distinguished from the thruster impulse by fitting the data over a range of (−2τn, 2τn) with a function of the form

x(t)={ANsin(ωnt)+x(0)cos(ωnt),t0AFsin(ωnt)+ANsin(ωnt)+x(0)cos(ωnt)t>0, (29)

where An is the amplitude of the noise and Af is the amplitude due to the impulse. Their stand was minimally damped, so they did not include a damping term. An exponential decay representing damping could be added to the fit for stands with greater damping (see Eqn. 10).

Fig. 14.

Fig. 14

Displacement sensor (LVDT) response as a function of time from an applied impulse.

If the impulse applied to the stand is known accurately, a good correlation between either the initial velocity or the maximum range and the applied impulse can be determined. An example calibration curve obtained with data similar to that shown in Fig. (14) is plotted in Fig. (15). Figure (16) displays a calibration curve for the torsional balance shown in Fig. (9) based on measurements of the initial velocity change due to impact hammer impulses. In both of these examples the transducer signal is not translated into actual displacement or velocity. As long as it is linearly proportional to the motion, the transducer signal can serve as the parameter that is correlated with thrust or impulse. Data such as these can be fit using linear least squares analysis to obtain an estimate of the sensitivity Scal. The same recommendations for the design and analysis of linear calibration curves listed above should be followed with impulse calibrations as well.

Fig. 15.

Fig. 15

Calibration curve obtained by measuring maximum LVDT signal range (which is proportional to the pendulum amplitude range) as a function of impact hammer impulse values [23].

Fig. 16.

Fig. 16

Calibration curve obtained by measuring the initial rate of LVDT signal change (which is proportional to the pendulum velocity in the linear range) as a function of impact hammer impulse values.

The thruster impulse must approximate a true impulsive load, F(t) = Ibitδ(t). In practice, a linear response can be obtained for finite pulse lengths, as long as they are much shorter than the natural frequency of the stand. Figure (17) shows a range of travel for varying impulse times τ divided by the stand’s natural period τn. As impulse times become greater than about 1/10 the stand’s natural period the results become nonlinear. Therefore we recommend that known calibration impulses be applied with pulse widths much less than the period of the stand.

Fig. 17.

Fig. 17

Thrust stand maximum deflection as a function of impulse pulse width normalized by the natural period of the balance [21].

V. Measurement Procedure and Data Reduction

A. Thrust

Data reduction for steady-state thrust measurements involves a straightforward application of the calibration curve to calculate thrust. To obtain the most reliable single point measurement of steady-state thrust, the following procedure is recommended. First, determine what level of error in the thrust measurement is tolerable. For early development activities relatively high uncertainty may be acceptable, while much greater precision and accuracy might be required for characterization of thrust for a flight program. Perform a minimum of ten calibrations to generate a calibration curve with small random errors and examine the curve for signs of systematic bias and short term drift. Compare to previous calibrations for signs of long term drift. If the calibration indicates that the thrust stand is performing as required, start the thruster and allow the it to reach thermal equilibrium and steady operation. Obtain an adequate number of measurements of the thrust stand transducer signal to calculate a mean value with sufficiently small standard error. Turn off the thruster power and flow rate and obtain measurements to characterize the zero (no load) transducer output. The difference between the transducer output with the thruster on and under no load conditions will be considered the response for that operating point. Repeat this measurement cycle if possible to characterize the repeatability of thrust measurements. Perform a minimum of ten calibrations after thruster operation to monitor shifts in the thrust stand sensitivity. If the calibrations taken before and after the thrust measurement indicate that the thrust stand response is stable (i.e., if differences in the calibrations result in contributions to the total error estimate that meet the requirements for that particular thruster), compute the thrust from the measured response.

An example of the transducer signal obtained with an NSTAR ion thruster [44] following this procedure is plotted in Fig. (18). The sudden drop in LVDT voltage is associated with turning off the high voltage to the engine. The main flow is shut off shortly after that, and small changes in the LVDT signal are apparent as the feed system lines downstream of the valve are evacuated. The zero signal is measured when the gas flow has stopped. Variations in the LVDT signal after that reflect the start of a calibration sequence. The thrust generated by the mass flow through the engine without power is often significant, particularly for electrothermal thrusters such as arc jets, and special measures may be required to properly characterize it. Thrust stands are often subject to rapid thermal transients when the engine is first turned off, and the thrust stand zero should be measured before these transients cause significant drift. This may necessitate the use of a flow shutoff valve very near the engine to minimize the blow-down thrust transient.

Fig. 18.

Fig. 18

Example of steady-state thrust measurement [44].

Time-resolved thrust measurements may be obtained from the time history of the transducer signal during thruster operation if the thrust stand zero is sufficiently stable. The error can be bounded by measuring the zero before and after thruster operation, and if the time-dependent variation in the zero can be determined, a correction may be applied to the data. Measurements of the temperature of the thrust stand components most susceptible to thermal effects may help guide the correction [13].

B. Impulse

Data collection for impulse measurements also mirrors the calibration process. After a single impulse, the response data are fitted with a function based on the expected thrust stand dynamics. Figure (19) shows an example of data obtained from a single firing of a pulsed plasma thruster with a torsional pendulum thrust stand. In this case, the data after the pulse have been fitted with a damped sinusoid to estimate the amplitude in the first period. The inset shows a low amplitude oscillation due to environmental vibrations prior to the impulse. This can be fit with a separate damped sinusoid or a range of data before and after the impulse can be fitted with a model that includes noise terms, as discussed above (Eqn. 29). The fits yield initial velocity or amplitude data that are converted to impulse bit values using the calibration data. Calibration before and after impulse measurements is also recommended to monitor drift in the thrust stand response.

Fig. 19.

Fig. 19

Example of an impulse thrust measurement [15].

VI. Errors and Uncertainty Analysis

A. Sources of Error

Instrument errors can be divided into two classes. Random errors are unavoidable at some level and typically are the aggregate result of many small effects, so they tend to follow a normal distribution with a mean of zero. Systematic errors tend to bias the response in a certain direction, so averaging over multiple samples yields a non-zero mean for the error. Different control strategies are employed for random and systematic errors. The uncertainty in the mean value due to random errors may be made arbitrarily small in principle by taking more samples of the measured quantity. Unlike random errors, a systematic bias may be characterized experimentally and subtracted from the measurement to produce a corrected result closer to the true value.

Sources of random error in pendulum thrust stand response include natural variability in the mechanical response (stiffness of various elements, for example), electrical noise pickup, which may be much worse during thruster operation, transmission of vibrations from the environment to the thrust stand, and vibration due to actuators such as valves on the thrust stand. Additional random errors may enter through the data analysis process, such as errors in the measurement of the distances from the pivot at which thruster and calibration loads are applied. Sources of systematic error include thermal drift, friction between moving and stationary thrust stand components, electromagnetic or electrostatic forces due to high currents or voltages, non-uniform response (amplification or attenuation of higher frequency thrust components, for example) facility effects such as gas currents, dimensional changes in components due to temperature changes, and drift due to changes in the stiffness of cabling or plumbing.

The calibration process also contributes to the total uncertainty. Random variation in the response to known, fixed loads generally represents a major part of the total uncertainty. Calibration in an environment that differs from that during thruster operation can also lead to random errors or bias. For example, the thermal environment, background pressure, gas flow currents, pressure in propellant lines, and current or voltage in electrical lines may be different or absent during calibration. If these are important parameters, they must be reproduced during calibration or characterized separately so that calibration or measurement data can be corrected. Additional sources of error depend on the particular calibration method. For example, the use of weights and a pulley, as described in section IV, involves uncertainties in the masses of the weights and the fiber or chain, pulley friction, and potential angular offsets in the fiber from the thrust axis.

B. Controlling Systematic Errors

The rate of thrust measurement drift due to thermal effects can be minimized with sufficient cooling along the thermal path between the thruster and the stand as well as through the use of materials with low thermal conductivity. Placing the stand within an actively cooled shroud will block convective and radiative heat loads to the stand. An effective electrical cable routing design can prevent cable expansion and contraction from pushing or pulling on the stand. Additionally, aligning the connection of electrical cables from the base of the stand to the moving assembly orthogonal to the direction of thrust prevents undesired variable forces on the stand. Active leveling control will eliminate changes in the canting of a thrust stand resulting from thermal fluctuations. Where possible, measuring electrical current in control electronics rather than voltage is advisable in order to avoid errors due to varying voltage drops across cabling caused by temperature fluctuations. Utilizing thermocouples in several locations on the thrust stand can aid in tracking thermal drift effects. As thermal drift is generally unavoidable, frequent stand recalibration is recommended.

Errors caused by friction in the system can be reduced through the use of linear and torsional springs in the thrust stand design. Ensuring that all moving parts are clear of electrical cables and other stationary objects through their entire range of motion is necessary to eliminate intermittent or variable friction and interference. In systems with active damping, free motion of the thrust stand can be verified by turning off the damping system. If there is no parasitic drag due to mechanical interference between moving and stationary parts, the amplitude of the thrust stand oscillations will exhibit a very slow decay. Rapid decay after an impulsive input is an indication of parasitic drag. Attention to cleanliness can prevent unwanted debris from obstructing the motion of the stand. Frequent calibration will also minimize error resulting from gradual changes in friction.

Standard vibrational isolation between the thrust stand base and the vacuum facility can be employed to minimize measurement error due to external sources of vibration. Vibrations can also be actively damped using a force actuator driven by a PID controller. Attaching physical stops that restrict the range of motion of the stand will prevent unexpected vibration or impulses from pushing the stand out of range and possibly damaging components.

Where possible, the use of non-ferrous materials in the thrust stand design can help mitigate measurement error due to undesired electromagnetic forces. Maximizing the distance between any magnetic field sources and affected thrust stand components will further reduce measurement errors. Using coaxial or twisted-pair cabling will also reduce interference. If the interaction is unavoidable, characterizing the magnetic tare across the range of possible settings can allow the error to be corrected during data reduction [25, 45].

C. Estimating Uncertainties in the Measurement

Despite the best efforts to minimize random errors and eliminate bias, measurement values will always have some uncertainty that represents the range within which the true value is likely to fall. Thrust and impulse measurements should always be reported with an estimate of the uncertainty. The uncertainty analysis involves several steps:

1. Specify equations used to calculate thrust or impulse.

The equations used in the data analysis should be written explicitly to identify the components subject to error. These are typically like Eqns. 21 and 28 that relate thrust or impulse to a transducer output with certain calibration measurements.

2. Identify sources of error.

Each part of the calibration, data collection, and data analysis processes should be examined to identify potential sources of systematic or random error. The list in Section VIA can serve as a guide, but each individual implementation will be subject to unique sources of uncertainty.

3. Correct for or quantify systematic errors.

The first tactic to employ with systematic bias is to determine the physical cause and attempt to eliminate it. Otherwise the bias should be characterized if possible and a correction applied to the thrust measurement. The uncertainty associated with the correction must be included in the overall uncertainty estimate. If the bias cannot be quantified due to sparse data, the uncorrected measurements should be reported with the probable presence of bias noted, and an uncertainty estimate based on the maximum observed bias included in the overall uncertainty.

4. Develop an error budget.

The uncertainty associated with each potential error source should be estimated and tabulated to assess the validity of analysis methods and quantify errors in the components of the thrust or impulse calculation. The error budget for a calibration process that employs linear model fits (as illustrated above) is used primarily to verify that the requirements of linear least squares analysis are satisfied. The error budget should verify that the uncertainty in the applied calibration loads is much less than the variability of the thrust stand response. If both the dependent and independent variables have significant uncertainty, conventional least squares analysis should not be used to estimate model parameters. Alternative methods that properly account for uncertainties in both variables are available [46]. Analysis of the linear fits should demonstrate that the linear model is correct and that disturbances are randomly and uniformly distributed.

The uncertainty of each error source should be characterized by either the standard deviation of multiple measurements or a confidence interval based on the standard deviation. The instrument uncertainty for NIST-traceable standards, such as mass balances or force transducers, may also be used to quantify errors. If statistical methods cannot be used to estimate variability in a component, reasonable physical bounds or engineering judgment can be employed, although these methods are discouraged. For components based on model fit parameters, the uncertainty should be based on the estimate of the variance for the dependent variable. For example, the thrust stand sensitivity is determined from the slope of the calibration line and has a standard deviation

sScal=sxi=1n(FiF¯)2, (30)

where F¯ is the average of the forces used in the calibration. The uncertainty in this parameter is reduced by increasing the number of measurements n, ensuring that the calibration measurements spans the range of expected thrust or impulse values, and distributing the calibration points uniformly across the range.

5. Aggregate component errors to determine thrust error.

The total uncertainty in the thrust measurement depends on the uncertainties of the individual components in the calculation. If the errors are independent, standard error propagation techniques can be used to determine the aggregate effect on calculated thrust or impulse [47]. For example, the uncertainty in thrust Ft calculated using Eqn. 21 is

σFtFt=[(σxx)2+(σScalScal)2+(σLtLt)2+(σLcalLcal)2]1/2, (31)

where σx can be approximated by sx (Eqn. 25), σScalsScal, and σLt and σLcal represent variability in the measurements of Lt and Lcal.

In some cases the thrust or impulse can be interpolated directly from a linear calibration curve. For example, if Lcal = Lt, the thrust or impulse can be inferred from the plot of response versus calibration loads. The uncertainty in interpolating a value of the independent parameter (Ft for example) from a measurement of the dependent variable (xt) is given by [48, 49]

sFt=sxScal[1N+1n+(x¯tx¯)2Scal2i=1n(FiF¯)2]1/2, (32)

where n is the number of calibration points, N is the number of repeat measurements performed at that operating condition, x¯t is the mean of the N repeat measurements of the thrust stand response, x¯ is the mean of the n responses to the calibration loads Fi, and F¯ is the mean of the n calibration values. This equation accounts for uncertainties in the thrust measurements as well as in the calibration curve. It highlights the value of repeat measurements in reducing uncertainty and the fact that higher sensitivity reduces error.

6. Control of drift.

Unfortunately, pendulum thrust stands are particularly prone to drift due, for instance, to thermal effects. Periodic calibrations or measurements with check standards can be used to control for changes in precision (susceptibility to random errors) and long term stability (systematic biases).

VII. Recommendations for Reporting Thrust Measurements

Reported thrust measurements should include quantitative estimates of the uncertainty and sufficient information on the measurement method to allow a reader to assess the reliability of the data. Publications should include:

  1. A brief description of the thrust stand, including the type of displacement sensor, damping mechanisms, and spring components.

  2. A description of the calibration procedure, including the method of applying known forces or impulses, the frequency of calibrations, how the thrust stand zero position is measured or inferred, the number of calibration points n, and the number of repetitions N at each point. A representative plot of calibration data showing the fit and standardized residuals like those shown in Figs. (11) and (16), and typical values of the square of the correlation coefficient obtained in calibrations should also be included.

  3. A quantitative measure of the repeatability of the thrust stand response (the standard deviation of multiple measurements, for instance) for given forces or impulses. The long term stability of the thrust stand and how drift was controlled or corrected in measurements should also be discussed.

  4. The resolution of the thrust stand and how it was determined. If the frequency-dependent thrust noise spectrum is important for the application, a plot of the noise floor similar to Fig. (5) should be included.

  5. The thrust stand response time and how it was measured, if the objectives of the study include time-resolved thrust characterization.

  6. A description of the measurement and data analysis methods such as the number of repetitions at a given operation point, how the thrust stand zero was determined, and curve fits employed in impulse measurements.

  7. A list of random and systematic error sources, a quantitative assessment of how much each contributes to the total error and how these values were measured or estimated, and a discussion of how systematic errors were controlled or corrected. The total uncertainty should be listed in any tables that include thrust measurements and shown as error bars or confidence intervals on plots of thrust.

VIII. Conclusions

Pendulum thrust stands can provide very accurate measurements of steady-state thrust, time-resolved thrust profiles, and impulse measurements when used properly. Hanging pendulum stands are generally the easiest to implement, but tend to be less sensitive and often require a large volume. With highly sensitive displacement measurement techniques and control of environmental vibrations and thermal drift, they can produce high resolution measurements, however. Inverted pendulum stands are typically smaller and more sensitive, and have been employed with great success to measure mN-level thrust in higher power thrusters. Torsional balances appear to be the most appropriate configuration for microthruster measurements (μN-level thrust) and impulse measurements (μNs-level impulse bits). The dimensions of the pendulum, mass of the thruster and mounting hardware, the stiffness of spring components, damping characteristics of the damping components, and the sensitivity of the displacement transducer are the design parameters that determine the dynamics of the stand and the measurement sensitivity.

Calibration of thrust stands with known forces or impulses is a key part of high fidelity thrust or impulse measurement. A number of force actuators are available that can be very accurately calibrated and used to impart calibration loads to stands. The design of the calibration procedure has a large influence on the uncertainty in the resulting measurement. Calibration and measurement approaches that determine the thrust stand zero (no-load position) and motion (which reflects the influence of environmental noise) for each measurement are the least susceptible to errors caused by drift.

Thrust measurements should always be corrected for known biases and reported with an estimate of the uncertainty based on a statistical analysis of the data. The error estimate involves documentation of the data analysis process, identification and characterization of potential error sources, estimates of the contributions of each error component, and careful aggregation of component errors into an estimate of the uncertainty in the calculated thrust or impulse. Careful design of the thrust balance and calibration procedure and a thorough examination of potential sources of error based on experience reviewed in this paper should result in very accurate, reliable thrust data.

Fig. 13.

Fig. 13

Electrostatic combs used to apply very small, precise calibration impulses [41].

Acknowledgments

The research described in this paper was carried out in part by the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement by the United States Government or the Jet Propulsion Laboratory, California Institute of Technology.

Nomenclature

AN

Noise amplitude, V

AF

Amplitude of thrust stand response due to impulse, V

b

Estimate of β from calibration fit, V

c

Damping constant, Nms/rad

d1, d2

Constants associated with damped motion

ei

Differences between predicted and measured responses to calibration loads, V

F

Applied force, N

F¯ =

Mean of calibration forces, N

Fcal

Calibration force, N

Fi

Calibration forces, N

Ft

Thrust force, N

F¯t

Amplitude of a periodic forcing function, N

G

Sensor responsivity, V/m

g

Acceleration due to gravity, m/s2

I

Moment of inertia, kg m2

Ibit

Impulse bit, Ns

k

Effective spring constant associated with restoring forces, Nm/rad

ks

Spring constant Nm/rad

L

Distance between pendulum pivot and point where force is applied, m

Lcal

Distance between pendulum pivot and point where calibration force is applied, m

Lcm

Distance from center of mass to pendulum pivot, m

Lpm

Distance between point of deflection measurement and pendulum pivot, m

Lt

Distance between pendulum pivot and point where thrust force is applied, m

Mt

Thruster mass, kg

m

Mass, kg

N

Number of repeat thrust measurements at a given operating point

ni

Number of calibration measurements

R

Correlation coefficient

Scal

Estimate of the thrust stand sensitivity S from calibration fit, m/N or V/N

sFt

Estimate of standard deviation of thrust measurement σFt, N

sScal

Estimate of standard deviation of thrust stand sensitivity, V/N

sx2

Estimate of variance σx2, V2

t

Time, s

ui

Disturbances (errors) in calibration measurements, V

Vss

Sensor output corresponding to linear displacement, V

W

Thruster weight, N

x

Linear displacement, m

x¯

Mean of measured responses to calibration loads, V

xi

Measured responses to calibration forces, V

x^i

Predicted responses to calibration loads, V

xFS

Full scale deflection, m

xss

Steady state linear displacement, m

x¯t

Mean of N repeat thrust measurements at a given operating point, N

S

Thrust stand sensitivity, m/N or V/N

Tg

Torque due to gravity, Nm

β

Intercept of calibration line, V

Δθ˙

Change in angular velocity due to impulse, rad/s

Δx˙

Change in linear velocity due to impulse, m/s

Δxss

Displacement of thrust stand, m

δ(t)

Dirac delta function

ζ

Damping coefficient

θ

Angular deflection, rad

θm

Maximum amplitude of oscillations, rad

θss

Steady state angular deflection under load, rad

θst

Steady state deflection due to a static load, rad

θz

Thrust stand tilt from the vertical axis, rad

σFt

Standard deviation of thrust measurement, V

σx2

Variance of thrust stand response to calibration loads, V2

τ

Impulse duration, s

τn

Natural period, s

Ω

Ratio of the frequency of a periodic load to the natural frequency

ω

Frequency of a periodic load, s−1

ωd

Frequency of damped motion, s−1

ωn

Natural frequency, s−1

References

  • [1].Angeles J, Dynamic Response of Linear Mechanical Systems: Modeling, Analysis and Simulation, Chapter 2, Springer, New York, NY, 2012. [Google Scholar]
  • [2].Koizumi H, Komurasaki K, and Arakawa Y, “Development of thrust stand for low impulse measurement from microthrusters,” Rev. Sci. Inst, Vol. 75, No. 10, 2004, pp. 3185–3190. [Google Scholar]
  • [3].McFall K and Tilley D, “Low Power Arcjet Performance Evaluation,” in “24th International Electric Propulsion Conference,” Moscow, Russia, 1995. IEPC 95–18. [Google Scholar]
  • [4].Lake J, Cavallaro G, Spanjers G, Adkison P, and Dulligan M, “Resonant operation of a microNewton thrust stand,” Tech. Rep. AFRL-PR-ED-TP-2002–308, Air Force Research Laboratory, Space and Missile Propulsion Division, Edwards AFB, CA, 2003. [Google Scholar]
  • [5].Nicolini D, Frigot P, Musso F, Cesare S, Castorina G, Ceruti L, Bartola F, Zanella P, Ceccanti F, Priami L, and Paita L, “Direct Thrust and Thrust Noise Measurements on the LISA Pathfinder Field Emission Thruster IEPC-2009–183,” in “31st International Electric Propulsion Conference,” Ann Arbor, MI, 2009. AIAA 2009–183. [Google Scholar]
  • [6].Hruby V et al. , “ST7-DRS Colloid Thruster System Development and Performance Summary,” in “44th Joint Propulsion Conference,” Hartford, CT, 2008. AIAA-2008–4824. [Google Scholar]
  • [7].Haag T, “Thrust stand for pulsed plasma thrusters,” Rev. Sci. Inst, Vol. 68, No. 5, 1997, pp. 2060–2067. [Google Scholar]
  • [8].Ziemer J, “Performance Measurements Using a Sub-Micronewton Resolution Thrust Stand,” in “27th International Electric Propulsion Conference,” Pasadena, CA, 2001. AIAA 2001–238. [Google Scholar]
  • [9].Jamison A, Ketsdever A, and Muntz E, “Gas dynamic calibration of a nano-Newton thrust stand,” Rev. Sci. Inst, Vol. 73, No. 10, 2002, pp. 3629–3637. [Google Scholar]
  • [10].Tew J, Driessche JVD, Lutfy F, Muntz E, Wong J, and Ketsdever A, “A Thrust Stand Designed for Performance Measurements of the Free Molecule Micro-Resistojet,” in “36th Joint Propulsion Conference,” Huntsville, AL, 2000. AIAA 2000–3673. [Google Scholar]
  • [11].Rocca S, Menon C, and Nicollini D, “FEEP micro-thrust balance characterization and testing,” Meas. Sci. Technol, Vol. 17, 2006, pp. 711–718. [Google Scholar]
  • [12].Cubbin E, Ziemer J, Choueiri E, and Jahn R, “Pulsed thrust measurements using laser interferometry,” Rev. Sci. Inst, Vol. 68, No. 6, 1997, pp. 2339–2346. [Google Scholar]
  • [13].Cesare S et al. , “Nanobalance: the European balance for micro-propulsion,” in “31st International Electric Propulsion Conference,” Ann Arbor, MI, 2009. AIAA 2009–182. [Google Scholar]
  • [14].Gamero-Castano M and Hruby V, “A torsional balance for the characterization of microNewton thrusters,” Rev. Sci. Inst, Vol. 74, No. 10, 2003, pp. 4509–4514. [Google Scholar]
  • [15].Yang Y, Tu L, Yang S, and Luo J, “A torsion balance for impulse and thrust measurements of micro-Newton thrusters,” Rev. Sci. Inst, Vol. 83, No. 3 015105. [DOI] [PubMed] [Google Scholar]
  • [16].Flores J, Ingle M, Robinson N, and Choudhuri A, “Development of a Torsional Thrust Balance for the performance evaluation of 100mN-5N thrusters,” in “47th Joint Propulsion Conference,” San Diego, CA, 2011. AIAA 2011–6016. [Google Scholar]
  • [17].He Z, Wu J, Zhang D, Lu G, Liu Z, and Zhang R, “Precision electromagnetic calibration technique for micro-Newton thrust stands,” Rev. Sci. Inst, Vol. 84, No. 5 055107. [DOI] [PubMed] [Google Scholar]
  • [18].Fowles G, Introduction to Modern Optics, 2nd Edition, Section 3.3, Dover Publications, Mineola, NY, 1989. [Google Scholar]
  • [19].Moeller T and Polzin K, “Thrust stand for vertically oriented electric propulsion performance evaluation,” Rev. Sci. Inst, Vol. 81, No. 11, 2010, p. 115108. [DOI] [PubMed] [Google Scholar]
  • [20].Polzin K, Markusic T, Stanojev B, DeHoyos A, and Spaun B, “Thrust stand for electric propulsion performance evaluation,” Rev. Sci. Inst, Vol. 77, No. 10, 2006, p. 105108. [DOI] [PubMed] [Google Scholar]
  • [21].Ketsdever A, D’Souza B, and Lee R, “Thrust Stand Micromass Balance for the Direct Measurement of Specific Impulse,” J. Prop. Power, Vol. 24, No. 6, 2008, pp. 1376–1381. [Google Scholar]
  • [22].Zafran S and Kemp R, “Colloid Microthruster Test Stand,” in “AIAA 3rd Flight Test, Simulation, and Support Conference,” Nashville, TN, 1969. AIAA 1969–314. [Google Scholar]
  • [23].Lilly T, Ketsdever A, Pancotti A, and Young M, “Development of a Specific Impulse Balance for Capillary Discharge Pulsed Plasma Thrusters,” J. Prop. Power, Vol. 25, No. 3, 2009, pp. 823–826. [Google Scholar]
  • [24].Pancotti A, Gilpin M, and Hilario M, “Comparison of electrostatic fins with piezoelectric impact hammer techniques to extend impulse calibration range of a torsional thrust stand,” Rev. Sci. Inst, Vol. 83, No. 3 025109. [DOI] [PubMed] [Google Scholar]
  • [25].Haag T, “Thrust stand for high power electric propulsion devices,” Rev. Sci. Inst, Vol. 62, No. 5, 1991, pp. 1186–1191. [Google Scholar]
  • [26].Xu K and Walker M, “High-Power, null-type, inverted pendulum thrust stand,” Rev. Sci. Inst, Vol. 80. [DOI] [PubMed] [Google Scholar]
  • [27].Nagao N, Yokota S, Komurasaki K, and Arakawa Y, “Development of a Dual Pendulum Thrust Stand for Hall Thrusters,” in “43rd Joint Propulsion Conference,” Cleveland, OH, 2007. AIAA 2007–5298. [DOI] [PubMed] [Google Scholar]
  • [28].Boccaletto L and d’Agostino L, “Design and Testing of a Micro-Newton Thrust Stand for FEEP,” in “36th Joint Propulsion Conference,” Huntsville, AL, 2000. AIAA 2000–3268. [Google Scholar]
  • [29].Manzella D et al. , “Evaluation of low power Hall thruster propulsion,” in “32nd Joint Propulsion Conference,” Lake Buena Vista, FL, 1996. AIAA 96–2736. [Google Scholar]
  • [30].Tartler B, Construction and Performance of an Inverted Pendulum Thrust Balance, Sections 3.2–3.5, Master’s thesis, Massachusetts Institute of Technology, Cambridge, MA, 2010. [Google Scholar]
  • [31].Manzella D and Jankovsky R, “Laboratory Model 50 kW Hall Thruster,” in “38th Joint Propulsion Conference,” Indianapolis, IN, 2002. AIAA 2002–3676. [Google Scholar]
  • [32].Garner C, Brophy J, Polk J, and Pless L, “Cyclic Endurance Test of a SPT-100 Stationary Plasma Thruster,” in “30th Joint Propulsion Conference,” Indianapolis, IN, 1994. AIAA 94–2856. [Google Scholar]
  • [33].Shabshelowitz A, Gallimore A, and Peterson P, “Performance of a Helicon Hall Thruster operating with Xenon, Argon, and Nitrogen,” J. Prop. Power, Vol. 30, No. 3, 2014, pp. 1–8. [Google Scholar]
  • [34].Pote B and Hruby V, “Performance of a Multi-Kilowatt Non-Circular Discharge Hall Thruster,” in “36th Joint Propulsion Conference,” Huntsville, AL, 2000. AIAA 2000–3249. [Google Scholar]
  • [35].Patterson M et al. , “NASA 30 cm Ion Thruster Development Status,” in “30th Joint Propulsion Conference,” Indianapolis, IN, 1994. AIAA 94–2849. [Google Scholar]
  • [36].Soulas G et al. , “Performance Test Results of the NASA-457M v2 Hall Thruster,” in “49th Joint Propulsion Conference,” Atlanta, GA, 2012. AIAA 2012–3940. [Google Scholar]
  • [37].Markusic T, Jones J, and Cox M, “Thrust Stand for Electric Propulsion Performance Evaluation,” in “40th Joint Propulsion Conference,” Fort Lauderdale, FL, 2004. AIAA 2004–3441. [Google Scholar]
  • [38].Chatterjee S and Price B, Regression Analysis by Example, Sections 1.6 and 1.7, John Wiley and Sons, New York, NY, 1977. [Google Scholar]
  • [39].Anscombe FJ, “Graphs in Statistical Analysis,” The American Statistician, Vol. 27, No. 1, 1973, pp. 17–21. [Google Scholar]
  • [40].Wilson M, Bushman S, and Burton R, “A Compact Thrust Stand for Pulsed Plasma Thrusters.” in “25th International Electric Propulsion Conference,” Cleveland, OH, 1997. IEPC 97–122. [Google Scholar]
  • [41].Selden N and Ketsdever A, “Comparison of force balance calibration techniques for the nano-Newton range,” Rev. Sci. Inst, Vol. 74, No. 12, 2003, pp. 5249–5254. [Google Scholar]
  • [42].Johnson W and Warne L, “Electrophysics of micromechanical comb actuators,” J. Microelectromechanical Systems, Vol. 4, No. 1, 1995, pp. 49–59. [Google Scholar]
  • [43].Ziemer J, Cubbin E, Choueiri E, and Birx D, “Performance characterization of a high efficiency gas-fed pulsed plasma thruster,” in “33rd Joint Propulsion Conference,” Seattle, WA, 1997. AIAA 2004–2925. [Google Scholar]
  • [44].Polk J, Anderson J, Brophy J, Rawlin V, Patterson M, and Sovey J, “The Results of an 8200 Hour Wear Test of the NSTAR Ion Thruster,” in “35th Joint Propulsion Conference,” Los Angeles, CA, 1999. AIAA-99–2446. [Google Scholar]
  • [45].Kodys A, Murray R, Cassady L, and Choueiri E, “An Inverted-Pendulum Thrust Stand for HighPower Electric Thrusters,” in “42nd Joint Propulsion Conference,” Atlanta, GA, 2006. AIAA 2006–4821. [Google Scholar]
  • [46].Fuller W, Measurement error models, Chapter 1, John Wiley and Sons, New York, NY, 1987. [Google Scholar]
  • [47].Taylor J, An Introduction to Error Analysis, Section 8.4, University Science Books, Mill Valley, CA, 1982. [Google Scholar]
  • [48].Salter C, “Error Analysis Using the Variance-Covariance Matrix,” Journal of Chemical Education, Vol. 77, No. 9, 2000, pp. 1239–1243. [Google Scholar]
  • [49].Prichard L and Barwick V, “Preparation of Calibration Curves A Guide to Best Practice,” Tech. Rep. LGC/VAM/2003/032, LGC Limited, 2003. [Google Scholar]