Accelerometer data collected with a minimum set of wearable sensors from subjects with Parkinson’s disease

Jean-Francois Daneault 1,2, Gloria Vergara-Diaz 1, Federico Parisi 1, Chen Admati 3, Christina Alfonso 4, Matilde Bertoli 1, Edoardo Bonizzoni 1, Gabriela Ferreira Carvalho 1, Gianluca Costante 1, Eric Eduardo Fabara 1, Naama Fixler 3, Fatemah Noushin Golabchi 1, John Growdon 5, Stefano Sapienza 1, Phil Snyder 6, Shahar Shpigelman 3, Lewis Sudarsky 7, Margaret Daeschler 8, Lauren Bataille 8, Solveig K Sieberts 6, Larsson Omberg 6, Steven Moore 4,9, Paolo Bonato 1,10,
PMCID: PMC7865022  PMID: 33547309

Abstract

Parkinson’s disease (PD) is a neurodegenerative disorder associated with motor and non-motor symptoms. Current treatments primarily focus on managing motor symptom severity such as tremor, bradykinesia, and rigidity. However, as the disease progresses, treatment side-effects can emerge such as on/off periods and dyskinesia. The objective of the Levodopa Response Study was to identify whether wearable sensor data can be used to objectively quantify symptom severity in individuals with PD exhibiting motor fluctuations. Thirty-one subjects with PD were recruited from 2 sites to participate in a 4-day study. Data was collected using 2 wrist-worn accelerometers and a waist-worn smartphone. During Days 1 and 4, a portion of the data was collected in the laboratory while subjects performed a battery of motor tasks as clinicians rated symptom severity. The remaining of the recordings were performed in the home and community settings. To our knowledge, this is the first dataset collected using wearable accelerometers with specific focus on individuals with PD experiencing motor fluctuations that is made available via an open data repository.

Subject terms: Parkinson's disease, Parkinson's disease


Measurement(s) body movement coordination trait • Movement Disorder Society Unified Parkinson’s Disease Rating Scale Questionnaire • Medication • motor coordination/balance trait • sleep pattern • MDS-UPDRS Tasks and Simulated Activities of Daily Living (in-clinic) • Activity of Daily Living
Technology Type(s) Accelerometer • body movement/behavior method • Clinical Observation • smartphone • Subject Diary
Factor Type(s) age of patient • gender of patient • timing of medication intake
Sample Characteristic - Organism Homo sapiens

Machine-accessible metadata file describing the reported data: 10.6084/m9.figshare.13342055

Background & Summary

Parkinson’s disease (PD) is a progressive neurodegenerative disorder that leads to severe impairments in quality of life due to both motor and non-motor symptoms. The prevalence of PD is estimated to be between 100 and 200/100,00013; and as the world population ages, the number of cases is expected to increase significantly4. While current treatment options include several types of medication and surgical options, the gold standard, L-3,4-dihydroxyphenylalanine (L-dopa), has remained the same over the last 50 years5.

L-dopa has been shown to effectively manage the severity of most motor symptoms of PD. Unfortunately, prolonged use of L-dopa can lead to unwanted side-effects termed motor fluctuations that are marked by wearing off, the abrupt loss of efficacy and re-emergence of tremor or bradykinesia prior to the next medication dose, and dyskinesias (involuntary writhing movements). In fact, the incidence of dyskinesia has been estimated at 30–50% five years after initiation of L-dopa treatment and 60–100% 10 years after treatment initiation68. Motor fluctuations produce substantial disability, lead to impaired quality of life, increased financial burden on the already overstressed healthcare system, and frequently make it challenging to identify an effective pharmacotherapy and titrate patients’ medications accordingly911. Medication intakes are commonly scheduled in order to minimize off states and dyskinesias12. In order to minimize motor fluctuations and their deleterious effects, there is a need for gaining a better understanding of their characteristics. Current methodologies for assessing dyskinesia and fluctuations in motor symptoms mainly rely on clinical scales and patient diaries1318. However, these are limited in their ability to capture longitudinal and real-world measures. The ubiquitous nature of wearable technology opens up the possibility for longitudinal monitoring in the home and community setting.

In order to derive measures that can be used for research, patient care, and clinical trials, we need algorithms to estimate the severity of motor symptoms and dyskinesia from data collected using wearable technology. We posited that a suitable way to achieve this goal was to collect data in the laboratory in order to have ground truth labels to assess the accuracy of algorithms and then to collect data in the home setting to assess feasibility of using such measures outside of the laboratory and compare the outcomes of both data collection paradigms. To this end, we developed the Levodopa Response Study. The study design is shown in Fig. 1. Study participants were recruited from 2 sites, Spaulding Rehabilitation Hospital (Boston, MA) and Mount Sinai Hospital (New York, NY). Subjects recruited in the study came to the laboratory on Day 1, while on their usual medication schedule, where they donned multiple sensors (GeneActiv device on the most affected upper limb, Pebble smartwatch on the least affected upper limb, and a Samsung Galaxy S3 Mini smartphone in a fanny pack worn in front at the waist) (Fig. 2). This sensor arrangement was devised as the minimum number of sensors we hypothesized would be necessary to capture whole-body information regarding the presence and severity of motor fluctuations. These specific devices were chosen for the purpose of testing different consumer-grade technologies and form-factors which could be easily deployed for continuous monitoring in the field.

Fig. 1.

Fig. 1

Illustration of the study protocol. Data collection started in the laboratory on Day 1 where a battery of motor tasks was performed multiple times by subjects and questionnaires were filled out. Data collection continued on Days 2 and 3 in the home setting and was completed in the laboratory on Day 4.

Fig. 2.

Fig. 2

Illustration of the sensor placement and cloud platform. Study volunteers donned a GeneActiv device on their most affected wrist, a Pebble smartwatch on their least affected wrist and a smartphone at the waist. Real-time data from the sensors embedded in the Pebble smartwatch and the smartphone were transmitted to a cloud platform through a custom-designed smartphone application. The sensor data could be visualized in real time by research staff. After completion of the protocol, the GeneActiv data was manually uploaded to the cloud platform. The combined data could then be accessed by researchers to perform analyses to be shared with the research team.

We know from previous studies that limb-specific symptom severity requires a larger number of sensors1922, but also that using multiple sensors increases patient burden and may not be feasible for long-term monitoring of patients participating in clinical trials or for disease management. For this reason, many research studies have used a smartphone2325 or a combination of a smartphone and a smartwatch26 to collect accelerometer data in the home and community settings and estimate motor symptom severity in individuals with PD. Using a minimum set of sensors does not allow one to monitor motor patterns displayed by individual body segments. However, it is unclear if this is necessary from a clinical point of view. To enable a comparison between monitoring individuals using a minimum set of sensors and monitoring them using sensors on each major body segment (i.e. upper limbs, lower limbs, and trunk), subjects recruited at Spaulding Rehabilitation Hospital were also outfitted with a set of five Shimmer 3 sensors (Shimmer Research Ltd, Dublin, Ireland), one on each limb and one on the pelvis. This subset of data is described in detail in the companion paper27.

During the laboratory visit, subjects first performed section III of the MDS-UPDRS28. Thereafter, to assess symptom fluctuations over a motor fluctuation cycle, subjects performed a battery of motor tasks that included some activities of daily living (ADL) and selected items of section III of the MDS-UPDRS. This battery of tasks lasted approximately 20 minutes and was repeated 6–8 times at 30-minute intervals. The protocol included rest periods. Subjects were encouraged to take breaks as needed throughout the study procedures. Afterward, subjects were sent home and instructed to wear the sensors for two days while conducting their usual activities. On Day 4, subjects returned to the laboratory and performed the same set of tasks as they did on Day 1. This time they were asked to arrive at the laboratory in a practically-defined off medication state (i.e., medications were withheld overnight for approximately 12 hours), and to take their medications after the first repetition of the above-mentioned battery of tasks, in order to assess the full range of symptoms and medication side-effects. At completion of the data collection, subjects doffed the sensors.

This dataset comprises wearable sensor data collected in the laboratory with ground truth labels of symptom severity during the performance of scripted motor tasks as well as wearable sensor data collected in the home setting during the performance of unscripted motor tasks. To our knowledge, this is the first dataset collected using wearable sensors in individuals with PD experiencing motor fluctuations that is made available to the scientific community via an open data repository. The dataset complements other publicly available wearable sensor datasets such as the mPower study29 and the Daphnet Freezing of Gait Dataset30. These datasets also consist of wearable sensor data collected from subjects with PD during the performance of motor tasks. However, the dataset herein presented has the added value of including clinician-assessed ground truth labels of symptom severity, focusing solely on individuals with PD experiencing motor fluctuations, and including a wide variety of motor tasks and additional sensors, as well as continuous recording over 4 days (see the Methods section for some exceptions). The continuous at-home monitoring data can inform researchers and clinicians on the variability of symptom severity and the characteristics of motor fluctuations that subjects experience daily. The dataset can be used not only to develop robust algorithms for the estimation of symptom severity, but also for activity recognition in individuals with PD and potentially for other clinically relevant applications. A portion of the dataset herein presented was recently utilized for the Parkinson’s Disease Digital Biomarker DREAM Challenge that aimed to identify the best data analysis methods to extract features from wearable sensor data for the estimation of the presence of different symptoms as well as their severity31. The data challenge showed that this dataset has great potential for enabling important advances in the management of symptoms and motor fluctuations in PD.

Methods

Participants

A total of 31 subjects with PD, who self-reported to experience motor fluctuations, with Hoehn & Yahr scores ranging from II to IV (ordinal scale of symptom progression)28, were enrolled in the study (see Fig. 3). Subjects were recruited and enrolled at two study sites: Spaulding Rehabilitation Hospital (n = 19) and Mount Sinai Hospital (n = 12). All subjects signed the informed consent form. Inclusion criteria were: (1) community dwelling men and women between 30 and 80 years of age with diagnosed PD, (2) currently taking L-dopa, (3) reporting at least mild dyskinesia, (4) reporting motor fluctuations, and (5) being able to operate a smartphone. Exclusion criteria were: (1) having other serious neurological condition (e.g. clinically significant stroke, brain tumor, hydrocephalus, epilepsy, other neurodegenerative disorder, encephalitis, repeated head trauma), or (2) having deep brain stimulation (DBS). All procedures were approved by the Institutional Review Board of both study sites (Spaulding IRB # 2014P000847; NY IRB # 14-1569). While 31 subjects were enrolled and completed the study protocol (see below), data for two subjects from Spaulding Rehabilitation Hospital and one from Mount Sinai Hospital were excluded (Fig. 3). Data from the first two individuals enrolled in the study was excluded because some of the motor tasks initially adopted in the study were modified according to issues encountered during the first assessments. Data for a third participant was excluded due to substantial quantity of missing data which was the result of a technical malfunction of the sensors.

Fig. 3.

Fig. 3

Illustration of subject onboarding. Note that 48 screened subjects did not meet the study inclusion criteria, 10 subjects who met the study inclusion criteria did not consent due to time commitment or having to come to the laboratory in a practically-defined off state, and all subjects that provided consent completed the protocol. However, data from 3 subjects were excluded from the dataset because of protocol change (n = 2) and a considerable amount of missing data (n = 1).

Data collection

Study volunteers were asked to wear a GeneActiv wristwatch on their most affected side, a Pebble smartwatch on their least affected side, and a smartphone at the waist. The GeneActiv wristwatch provides continuous accelerometer data and was set to collect data in the range ±8 G, at a sampling rate of 50 Hz. Custom-designed applications enabled the recording of continuous accelerometer data also from the Pebble-embedded sensor in the range ±4 G, also at a sampling rate of 50 Hz and from the smartphone-embedded sensor in the range ±2 G, at a sampling rate of 50 Hz. Specifically, the Michael J. Fox Foundation for Parkinson’s Research partnered with Intel® Corporation to develop the Fox Wearable Companion App (FWC App), a mobile and wearable application for PD research (see Fig. 4 for examples of the smartphone application user interface components). The FWC App is part of the Intel® Pharma Analytics Platform, an edge to cloud artificial intelligence solution that enables remote monitoring and continuously captures clinical data from study subjects using a variety of sensors, including wearable devices. In the study, accelerometer data collected using the smartwatch was streamed to the FWC App via Bluetooth and transmitted, together with the accelerometer data recorded from the smartphone-embedded sensor, to the cloud platform using an internet connection (Wi-Fi or mobile network). The FWC App provided also the ability to record patients’ reported outcomes, such as symptom severity, on/off state, and medication intake. It also provided the ability to perform and display a limited set of data aggregations and analytics, such as activity level during waking and sleeping hours. However, these features of the FWC App were not utilized in the current study. The cloud platform consisted of a scalable system where data could be securely stored and managed as well as processed using APIs for advanced data analytics.

Fig. 4.

Fig. 4

Smartphone application graphical user interface. Subjects were able to input information using the interface and were able to visualize the data from the Pebble watch and the phone.

Even though there is evidence in the literature that additional sensors (e.g., gyroscopes) could provide useful information for tracking symptoms and motor complications3235, we collected only accelerometer data to maximize the duration of the recordings without having to recharge the units and hence minimize subjects’ burden caused by the need to recharge the devices.

A summary of all the available data is shown in Table 1 and further details are provided in the following tables: Table 2 - Metadata of Patient Onboarding36, Table 3 - Metadata of Laboratory Visits36, Table 4 - Task Scores – Part I36, Table 5 - Sensor Data – Part I36, Table 6 - Subject Diary36, Table 7 - Sleep Diary36, Table 8 - Medication Diary36, and Table 9 - Feedback Survey36. Table 10 and Online-only Table 1 shows the duration and the percentage of valid data for each sensing device and for each subject for the entire data collection as well as the percentage of valid data for the laboratory visits and the recordings in the home and community settings.

Table 1.

Summary available data.

Task name Type of task and schedule Table Reference
Metadata of Patient Onboarding Survey – Once Table 236
Metadata of Laboratory Visits Survey – Twice Table 336
Task Scores – Part I Assessment - Twice Table 436
Sensor Data – Part I Activity - Four days Table 536
Subject Diary Survey - Twice Table 636
Sleep Diary Survey - Once Table 736
Medication Diary Survey - Once Table 836
Feedback Survey Survey - Once Table 936
Duration and Percentage of Valid Data (Total) Not Applicable Table 10

Duration and Percentage of Valid Data

(Laboratory visits and at-home period)

Not Applicable Online-only Table 1

Table 2.

Metadata of Patient Onboarding.

Variable name Variable details Variable unit
subject_id Alphanumeric
cohort PD
gender One of {‘Male’, ‘Female’}
birth_year Integer year
dominant_hand One of {‘Right’, ‘Left’}
upper_limb_length Real number cm
upper_arm_length Real number cm
lower_arm_length Real number cm
lower_limb_length Real number cm
thigh_length Real number cm
shank_length Real number cm
height Real number cm
weight Real number kg
visit_date Date
diagnosis_day Integer day
diagnosis_month Integer month
diagnosis_year Integer year
pd_most_affected_side One of {‘Right’, ‘Left’, ‘Bilateral’}
gait_impediments Boolean
posture_instability Boolean
tremor Boolean
bradykinesia Boolean
disrupted_sleep Boolean
freeze_of_gait Boolean
dyskinesia Boolean
rigidity Boolean
other_symptoms Text
last_levodopa_dose_timestamp Integer
regular_medication Text
geneActive_num Integer
pebble_num Alphanumeric
geneActive_hand One of {‘Right’, ‘Left’}
pebble_hand One of {‘Right’, ‘Left’}
smartphone_location One of {‘Right’, ‘Left’}
recording_start Time
recording_end Time
timezone Text
updrs_time Time
updrs_score_p1 Integer
updrs_score_p2 Integer
updrs_score_p3 Integer
updrs_score_p4 Integer
h_and_y_score Integer
updrs_second_visit_time Time
updrs_second_visit_score_p3 Integer

Table 3.

Metadata of Laboratory Visits.

Variable name Variable details
subject_id Alphanumeric
visit One of {‘1’, ‘2’}
clinical_assessment_timestamp Integer
medication_intake_timestamp Integer
medication_name Text
medication_dosage Text
timezone Text
second_medication_intake_timestamp Integer
stopwatch_start_timestamp Integer
fox_insight_app_start_timestamp Integer
geneActiv_start_timestamp Integer
general_comments Text

Table 4.

Task Scores – Part I.

Variable name Variable details
subject_id Alphanumeric
visit Integer
session Integer
task_id Integer
task_code One of {‘stndg’, ‘wlkgs’, ‘wlkgc’, ‘strsu’, ‘strsd’, ‘wlkgp’, ‘drawg’, ‘ftnr’, ‘ftnl’, ‘ramr’, ‘raml’, ‘ststd’, ‘typng’, ‘ntblt’, ‘drnkg’, ‘orgpa’, ‘fldng’, ‘sittg’}
repetition One of {‘1’, ‘2’}
timestamp_start Real number
timestamp_end Real number
phenotype One of {‘tremor’, ‘dyskinesia’, ‘bradykinesia’}
body_region One of {‘RightUpperLimb’, ‘LeftUpperLimb’, ‘LowerLimbs’}
score One of {‘Yes’, ‘No’, ‘NotApplicable’, ‘0’, ‘1’, ‘2’, ‘3’, ‘4’}

Table 5.

Sensor Data – Part I.

Variable name Variable details
subject_id Alphanumeric
device One of {‘GENEActiv’, ‘Pebble’, ‘Phone’}
device_position One of {‘LeftUpperLimb’, ‘LowerLimbs’, ‘RightUpperLimb’}
participant_day Integer
timestamp_start Real number
timestamp_end Real number
source_file Hyperlink
data_file_handle_id Hyperlink

Table 6.

Subject Diary.

Variable name Variable details
subject_id Alphanumeric
participant_day One of {‘2’, ‘3’}
session_label Text
session_number Integer
off Boolean
dyskinesia Boolean
troublesome_dyskinesia Boolean
tremor Boolean
freeze_of_gait Boolean
slowness_of_movements Boolean
comments Text

Table 7.

Sleep Diary.

Variable name Variable details
subject_id Alphanumeric
entry_id Integer
sleep_event_date Date
sleep_event_hour Time
timestamp Integer
sleep_event_type One of {‘fall_asleep_time’, ‘wake_up_time’}

Table 8.

Medication Diary.

Variable name Variable details
subject_id Alphanumeric
med_id Integer
med_timestamp_date Date
med_timestamp_hour Time
timestamp Integer
pd_related_meds_taken Text
other_meds_taken Text

Table 9.

Feedback Survey.

Variable name Variable details
subject_id Alphanumeric
charge_smartphone Integer
charge_pebble Integer
experience_watches Integer
experience_devices Integer
clearness_diary Integer
accuracy_diary Integer
additional_feedback_device_phone Text
additional_feedback_diary Text
additional_feedback_experiment Text

Table 10.

Total Duration and Percentage of Valid Data.

Subject ID Duration (hours) % Valid Data
GeneActiv Pebble Phone
3_BOS 76.96 100.00% 61.60% 77.70%
4_BOS 77.14 100.00% 0.00% 0.00%
5_BOS 78.80 100.00% 77.00% 15.80%
6_BOS 78.94 100.00% 58.30% 10.80%
7_BOS 78.45 100.00% 95.40% 94.90%
8_BOS 78.09 100.00% 96.70% 96.40%
9_BOS 77.00 100.00% 98.20% 97.80%
10_BOS 76.23 100.00% 66.70% 89.10%
11_BOS 76.71 100.00% 60.70% 96.80%
12_BOS 77.94 100.00% 70.30% 71.10%
13_BOS 76.69 100.00% 67.10% 99.30%
14_BOS 77.13 100.00% 76.40% 80.90%
15_BOS 76.45 100.00% 72.60% 89.40%
16_BOS 76.88 100.00% 99.80% 99.10%
17_BOS 78.70 100.00% 41.50% 3.40%
18_BOS 76.46 100.00% 79.90% 18.40%
19_BOS 76.71 100.00% 38.10% 38.80%
2_NYC 74.21 100.00% 39.80% 7.40%
3_NYC 73.78 100.00% 94.20% 20.00%
4_NYC 72.67 100.00% 55.20% 17.80%
5_NYC 73.54 100.00% 74.80% 20.80%
6_NYC 74.18 100.00% 100.00% 99.40%
7_NYC 74.92 100.00% 100.00% 99.40%
8_NYC 75.97 100.00% 99.30% 98.80%
9_NYC 75.43 100.00% 93.50% 93.00%
10_NYC 72.90 88.10% 18.60% 80.20%
11_NYC 72.53 100.00% 19.40% 70.50%
12_NYC 74.84 100.00% 79.90% 98.00%

Online-only Table 1.

Duration and percentage of valid data for the two laboratory visits and the at-home period.

Subject ID Visit 1 Laboratory (Day 1) Visit 2 Laboratory (Day 4) Home
Duration (hours) % Valid Data Duration (hours) % Valid Data Duration (hours) % Valid Data
GeneActiv Pebble Phone GeneActiv Pebble Phone GeneActiv Pebble Phone
3_BOS 4.59 100.00% 91.93% 95.71% 4.63 100.00% 96.50% 99.86% 67.74 100.00% 57.12% 75.02%
4_BOS 5.67 100.00% 0.00% 0.00% 3.34 100.00% 0.00% 0.00% 68.14 100.00% 0.00% 0.00%
5_BOS 4.67 100.00% 99.89% 28.31% 5.76 100.00% 59.26% 12.35% 68.37 100.00% 76.94% 15.22%
6_BOS 4.03 100.00% 2.10% 0.00% 6.79 100.00% 41.67% 3.56% 68.12 100.00% 63.28% 12.20%
7_BOS 4.16 100.00% 90.50% 89.99% 6.33 100.00% 49.00% 48.67% 67.96 100.00% 99.99% 99.52%
8_BOS 4.22 100.00% 100.00% 99.44% 5.31 100.00% 54.01% 53.93% 68.55 100.00% 99.82% 99.52%
9_BOS 3.94 100.00% 99.99% 99.47% 4.58 100.00% 70.51% 69.97% 68.48 100.00% 99.98% 99.54%
10_BOS 5.45 100.00% 100.00% 99.43% 4.92 100.00% 13.51% 65.79% 65.86 100.00% 67.93% 90.01%
11_BOS 4.61 100.00% 86.86% 86.42% 4.22 100.00% 0.00% 92.63% 67.88 100.00% 62.69% 97.81%
12_BOS 5.09 100.00% 96.06% 94.89% 4.72 100.00% 86.76% 86.77% 68.13 100.00% 67.23% 68.21%
13_BOS 5.00 100.00% 100.00% 99.31% 3.55 100.00% 100.00% 99.55% 68.14 100.00% 63.02% 99.34%
14_BOS 5.37 100.00% 100.00% 99.49% 3.00 100.00% 99.36% 98.69% 68.76 100.00% 73.56% 78.72%
15_BOS 4.74 100.00% 89.91% 92.22% 4.68 100.00% 89.17% 88.51% 67.04 100.00% 70.16% 89.23%
16_BOS 4.44 100.00% 100.00% 99.46% 3.62 100.00% 100.00% 99.47% 68.82 100.00% 99.73% 99.02%
17_BOS 4.24 100.00% 98.98% 0.00% 5.78 100.00% 8.43% 42.06% 68.68 100.00% 40.77% 0.35%
18_BOS 4.55 100.00% 95.97% 93.70% 4.15 100.00% 64.90% 0.00% 67.76 100.00% 79.74% 14.44%
19_BOS 5.18 100.00% 87.52% 84.84% 4.26 100.00% 67.55% 66.20% 67.28 100.00% 32.41% 33.55%
2_NYC 4.43 100.00% 99.37% 23.03% 4.67 100.00% 98.37% 13.44% 65.10 100.00% 31.55% 5.87%
3_NYC 4.18 100.00% 83.73% 16.00% 3.84 100.00% 96.90% 9.59% 65.77 100.00% 94.73% 20.81%
4_NYC 4.63 100.00% 75.33% 21.83% 3.75 100.00% 98.60% 17.17% 64.29 100.00% 51.19% 17.56%
5_NYC 4.29 100.00% 79.32% 15.68% 3.90 100.00% 100.00% 0.00% 65.35 100.00% 72.97% 22.37%
6_NYC 4.13 100.00% 100.00% 99.36% 3.61 100.00% 100.00% 99.35% 66.44 100.00% 99.98% 99.44%
7_NYC 4.00 100.00% 100.00% 99.36% 2.83 100.00% 100.00% 99.42% 68.09 100.00% 99.99% 99.35%
8_NYC 4.14 100.00% 100.00% 99.45% 4.13 100.00% 88.49% 88.14% 67.69 100.00% 99.97% 99.45%
9_NYC 3.93 100.00% 100.00% 99.35% 5.27 100.00% 74.69% 74.41% 66.24 100.00% 94.65% 94.07%
10_NYC 3.88 100.00% 100.00% 99.19% 2.75 100.00% 100.00% 99.44% 66.27 86.91% 10.51% 78.26%
11_NYC 4.09 100.00% 100.00% 99.43% 3.48 100.00% 92.52% 92.27% 64.97 100.00% 10.42% 67.49%
12_NYC 4.37 100.00% 100.00% 99.31% 3.73 100.00% 100.00% 99.43% 66.74 100.00% 77.43% 97.79%

Accelerometer data was generally collected over 4 consecutive days36. However, for four of the subjects recruited in the New York site (3_NY; 4_NY; 10_NY; 11_NY) there was a gap between the data collected during Day 3 (in-home) and the data collected during Day 4 of the study (second laboratory visit) because of scheduling issues. In other words, for some subjects, it was not possible to schedule the second lab visit 3 days after initiating the study and hence data was collected for additional days before study volunteers were able to come to the laboratory. Data collected between the end of Day 3 and the beginning of the day of the second laboratory visit (herein referred to as Day 4) was discarded so that all the subjects had 4 days of data recordings. For subject 10_NY, the gap between Day 3 and the day of the second laboratory visit was approximately 19 days. The GeneActiv sensor, which could not be charged at home, stopped recording data during the gap period and had to be replaced with a new unit in the laboratory just before the beginning of the second laboratory visit. In contrast, the Pebble smartwatch and the smartphone kept recording for the entire period as the subject recharged them periodically. Furthermore, for subject 11_NY, the research team swapped the GeneActiv from the left wrist to the right wrist between the first and the second session (after 36 min and 34 s of data recording).

Acceleration in the three cartesian coordinate axes, as well as the vector magnitude are reported for the three devices in m/s2. Sensor data timestamps are reported using a Unix epoch timestamp notation, from which it is possible to derive the exact date and time of each data sample. In addition to the acceleration data, clinical labels of symptom severity and symptom presence are provided for each limb and each motor task36 as generated by a clinician during the in-laboratory sessions36. Limb-specific (i.e. left upper limb, right upper limb, and lower limbs) tremor severity scores (0–4) are provided, as well as upper-limb and lower-limb presence of dyskinesia (yes or no) and bradykinesia (yes, no, or not applicable).

Protocol

Day 1: In-clinic monitoring

On the first day of data collection, subjects came to the laboratory in an on medication state, answered demographic as well as medical history questions, were measured and weighed, and donned the sensors on specific limbs36. Clinical symptoms were assessed using the Movement Disorders Society Unified Parkinson’s Disease Rating Scale (MDS-UPDRS)36. Then, subjects performed the first testing block which comprised several motor tasks. These motor tasks are standing (stndg), walking in a straight line for 30 s (wlkgs), walking in a straight line for 30 s while counting backwards (wlkgc), walking up the stairs (strsu), walking down the stairs (strsd), walking through a narrow corridor (wlkgp), finger-to-nose for 15 s (twice with each arm) (ftnr and ftnl), alternating hand movements for 15 s (twice with each arm) (ramr and raml), drawing (drawg), typing on a keyboard for 30 s (typng), opening a bottle and pouring water (three times) (drnkg), arranging sheets of paper in a folder (twice) (orgpa), sit-to-stand-to-sit (three times) (ststd), assembling nuts and bolts for 30 s (ntblt), folding a towel three times (fldng), and sitting (sittg)36. This testing block (except for walking up and down the stairs) was repeated every 30 minutes for 3 to 4 hours (6 to 8 repetitions). During each task, a trained clinician assessed the severity (tremor) or presence (bradykinesia and dyskinesia) of symptoms for each limb separately36. Note that the clinical researchers who provided the clinical scores were all MDS-UPDRS certified. Also, we organized the rating task so that a given clinical researcher provided symptom scores for all the repetitions of a given task.

At the end of the visit, subjects were instructed on how to use the custom smartphone application and on how and when to remove, recharge, and put the devices back on. They were provided with a printed at-home instruction manual, containing detailed descriptions of the procedures that were explained to them in the laboratory.

Days 2-3: At-home monitoring

Once the laboratory data collection was completed, subjects went home while still wearing the sensors. Subjects wore the sensors at home for 2 complete days while they performed their usual daily activities. The GeneActiv sensor did not need to be recharged and could be worn at all times. The Pebble sensor and the smartphone required to be charged once a day (participants were instructed to charge these two devices preferably at night). The GeneActiv and the Pebble sensors were water-resistant, and it was possible for study participants to keep them on while showering. Subjects also recorded medication intake times and doses, and the sleep and wake up times36.

Day 4: In-clinic monitoring

On Day 4, study volunteers returned to the laboratory, but this time in an off medication state (i.e. without taking their regularly scheduled morning dose of medication/s which led to a minimum medication withdrawal time of 10 hours with the majority of subjects having withheld medication/s for at least 12 hours). A portion of the procedures carried out during the data collection on Day 1 were repeated, starting with section III (motor assessment) of the UPDRS36. After the first testing block, that was carried out off medications, subjects took their regularly scheduled morning medication dose and the following 5 to 7 repetitions of the above-mentioned battery of tasks were completed according to the same timeline as on Day 1 (i.e. every 30 minutes)36. The same trained clinical researchers provided scores for symptom severity or presence/absence clinical scores for all the repetitions of all the tasks36. Note that the same clinical researcher provided symptom severity for both the in-clinic sessions of a given subject (i.e. for both the Day 1 and Day 4 sessions). However, different clinical researchers examined different subjects. Once completed, subjects doffed the sensors and were asked to complete a feedback questionnaire regarding the use of the technology36.

It is worth noting that two participants deviated from the protocol: one subject (4_BOS) arrived in the off state to the laboratory on Day 1 and thus was asked to arrive in the on state on Day 4. Another subject (3_BOS) had a medication intake before the beginning of the second laboratory visit (Day 4) (4 hours before the session) and therefore was not in a practically-defined off state.

Using this protocol, we recorded approximately 4 days of continuous wearable sensor data (Table 536); including 12 to 16 laboratory testing blocks containing data recorded during the performance of specific motor tasks36 across a range of medication states in individuals with PD exhibiting motor fluctuations. The specified motor tasks were labeled with clinical symptom severity or presence/absence scores (Table 436). In addition, we captured 2 days of unlabeled home data. We also captured demographic and clinical data (Table 236), as well as patient self-reported diaries (Tables 6, 7 and 836) and feedback regarding the use of the technology (Table 936).

Data pre-processing

The raw sensor data from the GeneActiv, Pebble and smartphone was pre-processed in order to achieve the following objectives:

  1. Identify intervals with missing data in the raw signals

  2. Resample the time series with a sampling rate of 50 Hz

  3. Temporally align the signals collected using different devices

All the pre-processing and alignment procedures were carried out using MATLAB (Mathworks, Natick, MA).

First, the raw data collected using each device was processed by filling gaps in the time series due to missing data. Gaps were filled using sequences of NaN’s (Not-a-Number’s, i.e., not valid values), according to the original sampling rate (i.e., 50 Hz). This allowed us to represent the signals as time series for the entire duration of the data collection, with timestamp vectors containing only increasing valid values and acceleration signals including both valid and invalid data corresponding to valid and missing values in the original raw signals, respectively. At this point, each time series could still be marked by uneven sampling intervals. Hence, we carried out a resampling procedure using a linear interpolation method thus resulting in an evenly sampled time series with a sampling rate exactly equal to 50 Hz. Then, the resampled signals were temporally aligned by exploiting a simultaneous physical “shake” of all the devices that was done at the beginning of the first session (Day 1) and at the end of the last session (Day 4) in the clinic. The “shake” event consisted in intense upward/downward movements of all devices held together. This was done by a member of the research staff in the laboratory. The event was associated with an easily distinguishable pattern in the accelerometer time series of each device, which enabled the extraction of temporal offsets between the reference sensor (the GeneActiv device) and the other two devices at the two different points in time when the “shake” event occurred (beginning of the laboratory session on Day 1 and end of the laboratory session on Day 4). This was achieved by using a cross-correlation based algorithm. Since the internal clocks of the devices were subject to drift, the offsets on Day 1 could be slightly different from those on Day 4. In order to address this issue, the magnitude of the drift was computed from the difference between the offsets on Day 1 and Day 4 for the non-reference devices. Then, the drift was removed under the assumption that it developed linearly during the entire data collection. The drift-free time series of the Pebble smartwatch and the smartphone were obtained by removing this linear trend from their time axis. Finally, the time alignment between all devices was achieved by shifting the timestamp vector of the non-reference devices by the offsets computed for Day 1. The correctness of this procedure was visually validated by checking the alignment of the sensor data corresponding to the “shake” event on Day 4. The results showed an error in the time synchronization among devices that was always below 100 ms, which was considered negligible. The resulting aligned signals were then saved and posted on Synapse.org.

Dataset descriptive statistics

A total of 6911 tasks were performed during the two laboratory visits by the 28 subjects whose data is shared as part of this manuscript. The distributions of the clinical scores assigned to all the motor tasks performed during the laboratory visits are shown in Fig. 5. The number of instances for both the upper limbs and the lower limbs (combined) contributing to the total amount of clinical scores for each severity or presence/absence of symptoms is highlighted (with different colors) in both the pie charts and in the text labels.

Fig. 5.

Fig. 5

Distribution of the clinical scores for (a) tremor, (b) dyskinesia, and (c) bradykinesia related to the motor tasks performed during the laboratory visits.

Table 10 shows the total duration of the collected data and the overall percentage of valid data for each sensing device and for each subject. Detailed information on the duration and the percentage of valid data for the two laboratory visits and the recordings in the home and community settings are provided in Online-only Table 1.

Data Records

De-identified study data, consisting of questionnaire responses and sensor data (Pebble smartwatch, GeneActiv unit, and smartphone), were exported to Synapse. Synapse is a general-purpose data and analysis sharing service where members can work collaboratively, analyze data, share insights and have attributions and provenance of those insights to share with others. Synapse is developed and operated by Sage Bionetworks.

A total of 31 individuals consented to participate in the study and completed the data collections. Of those participants, 28 had data that could be utilized for analysis and shared. As mentioned above, data from two subjects was excluded due to a change in study protocol, and data from an additional subject was excluded due to excessive quantity of missing data (due to a technical problem with the sensors). All data contributed by study participants are listed in Table 1.

All coded datasets (Table 136) are stored and are accessible via the Synapse platform with associated metadata and documentation and can be accessed at the following URL: 10.7303/syn20681023

Technical Validation

The data herein provided was collected using devices with proprietary technical validation. Hence, we do not provide test-retest nor other technical validation datasets. However, others have reported technical validation data for the sensors utilized in the study37,38. Also, all metadata and sensor data were visually inspected by trained research staff.

Usage Notes

Researchers who are interested in accessing the data need to complete the following steps:

  1. Have a Synapse account (https://synapse.org)

  2. Have their Synapse User Profile validated by the Synapse Access and Compliance Team (ACT)

  3. Become a Synapse Certified user

  4. Submit an Intended Data Use statement

  5. Agree to the Conditions for Use associated with each data source (see DOIs for each data source)

While certain data types may have additional Conditions for Use (e.g. clinical scale copyrights), the overarching Conditions for Use are as follows:

  • You confirm that you will not attempt to re-identify research participants for any reason, including for re-identification theory research.

  • You reaffirm your commitment to the Synapse Awareness and Ethics Pledge.

  • You agree to abide by the guiding principles for responsible research use and data handling as described in the Synapse Governance documents.

  • You commit to keeping the data confidential and secure.

  • You agree to use the data exclusively as described in your submitted Intended Data Use statement.

  • You understand that the data may not be used for commercial advertisement or to re-contact research participants.

  • You agree to report any misuse or data release, intentional or inadvertent to the ACT within 5 business days by emailing act@sagebase.org.

  • You agree to publish findings in open access publications.

  • You promise to acknowledge the L-dopa study investigators in all publications and presentations resulting from using the data as follows: “These data were part of the L-dopa study funded by the Michael J Fox Foundation”.

Download the data

The data are stored in the Synapse data repository and can be accessed with different modalities:

  1. Web-based download: the user can individually download each file directly from the web browser;

  2. Python, R, and command line clients;

  3. REST API.

Additional information and code examples about the data access procedures for this specific dataset can be found at https://www.synapse.org/#!Synapse:syn20681023/wiki.

Generic documentation about the APIs for interacting with Synapse data repositories are available at https://docs.synapse.org/articles/api_documentation.html.

Acknowledgements

The authors would like to thank all the subjects for their participation in the data acquisitions as well as all support staff that helped in the performance of this study. This study was supported by a grant from the Michael J. Fox Foundation for Parkinson’s Research.

Online-only Table

Author contributions

Jean-Francois Daneault, Gloria Vergara-Diaz, Naama Fixler, Fatemah Noushin Golabchi, Shahar Shpigelman, Margaret Daeschler, Lauren Bataille, Steven Moore, and Paolo Bonato contributed to the design of the study. Jean-Francois Daneault, Gloria Vergara-Diaz, Chen Admati, Matilde Bertoli, Edoardo Bonizzoni, Gabriela Ferreira Carvalho, Gianluca Costante, Eric Eduardo Fabara, Naama Fixler, Fatemah Noushin Golabchi, John Growdon, Stefano Sapienza, Christina Alfonso, Shahar Shpigelman, Lewis Sudarsky, Steven Moore, and Paolo Bonato helped with different aspects related to the implementation of the research protocol including data collection. Jean-Francois Daneault, Gloria Vergara-Diaz, Federico Parisi, Gianluca Costante, Fatemah Noushin Golabchi, Stefano Sapienza, Phil Snyder, Solveig Sieberts, Larsson Omberg, and Paolo Bonato contributed to curating and posting the data to Synapse. Jean-Francois Daneault, Gloria Vergara-Diaz, Federico Parisi and Paolo Bonato wrote the manuscript. All authors provided editorial feedback and contributed to the final approval of the manuscript.

Code availability

The only data processing procedures that we performed on the dataset were the ones described above. The first procedure was carried out to temporally align the data collected using different sensors. The second procedure was carried out to obtain an evenly-sampled timeseries.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.de Rijk MC, et al. Prevalence of Parkinson’s disease in Europe: A collaborative study of population-based cohorts. Neurologic Diseases in the Elderly Research Group. Neurology. 2000;54:S21–3. [PubMed] [Google Scholar]
  • 2.de Rijk MC, et al. Prevalence of parkinsonism and Parkinson’s disease in Europe: the EUROPARKINSON Collaborative Study. European Community Concerted Action on the Epidemiology of Parkinson’s disease. J. Neurol. Neurosurg. Psychiatry. 1997;62:10–15. doi: 10.1136/jnnp.62.1.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.de Rijk MC, et al. Prevalence of Parkinson’s disease in the elderly: the Rotterdam Study. Neurology. 1995;45:2143–6. doi: 10.1212/WNL.45.12.2143. [DOI] [PubMed] [Google Scholar]
  • 4.Rossi A, et al. Projection of the prevalence of Parkinson’s disease in the coming decades: Revisited. Mov. Disord. 2018;33:156–159. doi: 10.1002/mds.27063. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Poewe, W., Antonini, A., Zijlmans, J. C., Burkhard, P. R. & Vingerhoets, F. Levodopa in the treatment of Parkinson’s disease: an old drug still going strong. Clinical interventions in aging (2010). [DOI] [PMC free article] [PubMed]
  • 6.Van Gerpen JA, Kumar N, Bower JH, Weigand S, Ahlskog JE. Levodopa-associated dyskinesia risk among Parkinson disease patients in Olmsted County, Minnesota, 1976–1990. Arch. Neurol. 2006;63:205–209. doi: 10.1001/archneur.63.2.205. [DOI] [PubMed] [Google Scholar]
  • 7.Ahlskog JE, Muenter MD. Frequency of levodopa-related dyskinesias and motor fluctuations as estimated from the cumulative literature. Mov. Disord. 2001;16:448–458. doi: 10.1002/mds.1090. [DOI] [PubMed] [Google Scholar]
  • 8.Rascol O, et al. A Five-Year Study of the Incidence of Dyskinesia in Patients with Early Parkinson’s Disease Who Were Treated with Ropinirole or Levodopa. N. Engl. J. Med. 2000;342:1484–1491. doi: 10.1056/NEJM200005183422004. [DOI] [PubMed] [Google Scholar]
  • 9.Hechtner, M. C. et al. Quality of life in Parkinson’s disease patients with motor fluctuations and dyskinesias in five European countries. Park. Relat. Disord. 10.1016/j.parkreldis.2014.06.001 (2014). [DOI] [PubMed]
  • 10.Lang AE, Lozano AM. Parkinson’s disease. First of two parts. N. Engl. J. Med. 1998 doi: 10.1056/NEJM199810083391506. [DOI] [PubMed] [Google Scholar]
  • 11.Lang AE, Lozano AM. Parkinson’s disease: Second of two parts. New England Journal of Medicine. 1998 doi: 10.1056/NEJM199810153391607. [DOI] [PubMed] [Google Scholar]
  • 12.Rodríguez-Molinero A, et al. Remote control of apomorphine infusion rate in Parkinson’s disease: Real-time dose variations according to the patients’ motor state. A proof of concept. Parkinsonism and Related Disorders. 2015 doi: 10.1016/j.parkreldis.2015.04.030. [DOI] [PubMed] [Google Scholar]
  • 13.Carignan B, Daneault JF, Duval C. Assessing drug-induced dyskinesia in the clinic, the laboratory and the natural environment of patients. J. Parkinsons. Dis. 2011;1:329–337. doi: 10.3233/JPD-2011-11054. [DOI] [PubMed] [Google Scholar]
  • 14.Goetz CC. The Unified Parkinson’s Disease Rating Scale (UPDRS): Status and recommendations. Movement Disorders. 2003;18:738–750. doi: 10.1002/mds.10473. [DOI] [PubMed] [Google Scholar]
  • 15.Vizcarra, J. A. et al. The Parkinson’s disease e‐diary: Developing a clinical and research tool for the digital age. Mov. Disord. 10.1002/mds.27673 (2019). [DOI] [PMC free article] [PubMed]
  • 16.Hauser, R. A. et al. Prevalence of Dyskinesia and OFF by 30-Minute Intervals Through the Day and Assessment of Daily Episodes of Dyskinesia and OFF: Novel Analyses of Diary Data from Gocovri Pivotal Trials. J. Parkinsons. Dis. 10.3233/jpd-181565 (2019). [DOI] [PMC free article] [PubMed]
  • 17.Hauser, R. A. et al. A home diary to assess functional status in patients with Parkinson’s disease with motor fluctuations and dyskinesia. Clin. Neuropharmacol. 10.1097/00002826-200003000-00003 (2000). [DOI] [PubMed]
  • 18.Hauser, R. A., Deckers, F. & Lehert, P. Parkinson’s disease home diary: Further validation amd implications for clinical trials. Mov. Disord. 10.1002/mds.20248 (2004). [DOI] [PubMed]
  • 19.Eskofier BM, et al. Recent machine learning advancements in sensor-based mobility analysis: Deep learning for Parkinson’s disease assessment. 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2016;2016-Octob:655–658. doi: 10.1109/EMBC.2016.7590787. [DOI] [PubMed] [Google Scholar]
  • 20.Lee SI, et al. A novel method for assessing the severity of levodopa-induced dyskinesia using wearable sensors. 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2015;2015-Novem:8087–8090. doi: 10.1109/EMBC.2015.7320270. [DOI] [PubMed] [Google Scholar]
  • 21.Daneault, J. F. et al. Estimating Bradykinesia in Parkinson’s Disease with a Minimum Number of Wearable Sensors. in 2017 IEEE/ACM International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE) 264–265, 10.1109/CHASE.2017.94 (2017).
  • 22.Patel S, et al. Monitoring Motor Fluctuations in Patients With Parkinson’s Disease Using Wearable Sensors. IEEE Trans. Inf. Technol. Biomed. 2009;13:864–873. doi: 10.1109/TITB.2009.2033471. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lipsmeier, F. et al. Evaluation of smartphone-based testing to generate exploratory outcome measures in a phase 1 Parkinson’s disease clinical trial. Mov. Disord. 10.1002/mds.27376 (2018). [DOI] [PMC free article] [PubMed]
  • 24.Lee, W., Evans, A. & Williams, D. R. Validation of a smartphone application measuring motor function in Parkinson’s disease. J. Parkinsons. Dis. 10.3233/JPD-150708 (2016). [DOI] [PubMed]
  • 25.Borzì, L. et al. Home monitoring of motor fluctuations in Parkinson’s disease patients. J. Reliab. Intell. Environ. 10.1007/s40860-019-00086-x (2019).
  • 26.Sharma, V. et al. Spark: Personalized parkinson disease interventions through synergy between a smartphone and a smartwatch. in Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)10.1007/978-3-319-07635-5_11 (2014).
  • 27.Vergara-Diaz, G. et al. Limb and trunk accelerometer data collected with wearable sensors from subjects with Parkinson’s disease. Sci Data10.1038/s41597-021-00831-z (2021) [DOI] [PMC free article] [PubMed]
  • 28.Goetz CG, et al. Movement Disorder Society-Sponsored Revision of the Unified Parkinson’s Disease Rating Scale (MDS-UPDRS): Scale presentation and clinimetric testing results. Mov. Disord. 2008;23:2129–2170. doi: 10.1002/mds.22340. [DOI] [PubMed] [Google Scholar]
  • 29.Bot, B. M. et al. The mPower study, Parkinson disease mobile data collected using ResearchKit. Sci. Data10.1038/sdata.2016.11 (2016). [DOI] [PMC free article] [PubMed]
  • 30.Bächlin, M. et al. Wearable assistant for Parkinsons disease patients with the freezing of gait symptom. IEEE Trans. Inf. Technol. Biomed. 10.1109/TITB.2009.2036165 (2010). [DOI] [PubMed]
  • 31.Sage Bionetworks. Parkinson’s Disease Digital Biomarker DREAM Challenge. (2018).
  • 32.Tsipouras MG, et al. An automated methodology for levodopa-induced dyskinesia: Assessment based on gyroscope and accelerometer signals. Artif. Intell. Med. 2012;55:127–135. doi: 10.1016/j.artmed.2012.03.003. [DOI] [PubMed] [Google Scholar]
  • 33.Ossig, C. et al. Wearable sensor-based objective assessment of motor symptoms in Parkinson’s disease. Journal of Neural Transmission10.1007/s00702-015-1439-8 (2016). [DOI] [PubMed]
  • 34.Shawen N, et al. Role of data measurement characteristics in the accurate detection of Parkinson’s disease symptoms using wearable sensors. J. Neuroeng. Rehabil. 2020 doi: 10.1186/s12984-020-00684-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.López-Blanco, R. et al. Smartwatch for the analysis of rest tremor in patients with Parkinson’s disease. J. Neurol. Sci. 10.1016/j.jns.2019.04.011 (2019). [DOI] [PubMed]
  • 36.2019. Motion Analysis Laboratory, D. O. P. M. &, R. MJFF Levodopa Response Study. Synapse. [DOI]
  • 37.Esliger DW, et al. Validation of the GENEA accelerometer. Med. Sci. Sports Exerc. 2011;43:1085–1093. doi: 10.1249/MSS.0b013e31820513be. [DOI] [PubMed] [Google Scholar]
  • 38.Thomaz, E., Essa, I. & Abowd, G. D. A practical approach for recognizing eating moments with wrist-mounted inertial sensing. In Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing - UbiComp ’15 1029–1040, 10.1145/2750858.2807545 (2015). [DOI] [PMC free article] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Citations

  1. 2019. Motion Analysis Laboratory, D. O. P. M. &, R. MJFF Levodopa Response Study. Synapse. [DOI]

Data Availability Statement

The only data processing procedures that we performed on the dataset were the ones described above. The first procedure was carried out to temporally align the data collected using different sensors. The second procedure was carried out to obtain an evenly-sampled timeseries.


Articles from Scientific Data are provided here courtesy of Nature Publishing Group