Abstract
The glucagon-like peptide-1 receptor agonist exenatide (EXT) is an effective treatment for type 2 diabetes. However, this peptide has a short biological half-life and the delayed release characteristic of current formulations limit its clinical application. Herein, we prepared EXT-loaded inside-porous poly(d,l-lactic-co-glycolic acid (PLGA) microspheres with outside layers (EXT-PMS) using a W1/O/W2 emulsion method with a microfluidic technique and its fabrication and formulation conditions were systematically investigated. In vitro dissolution experiments showed that the PLGA concentration, proportion of drug and oil phase, and the number and size of pores strongly affected the release behaviors of EXT-PMS. In vitro, the optimized EXT-PMS with large internal pores exhibited rapid and stable release without a lag phase. In a rat model, subcutaneous administration of the product yielded plasma concentrations of EXT that was sustained for 30 days with low burst and no delayed-release effect. The preparation of inside-porous microspheres is lighting up the development of long-acting drug delivery systems for other drugs with favorable release characteristics.
Keywords: Exenatide, inside-porous microspheres, long-acting, release behavior, type 2 diabetes
1. Introduction
Type 2 or noninsulin-dependent diabetes accounts for 90–95% of all patients with diabetes and is a chronic disease with substantial morbidity and mortality. Patients with type 2 diabetes have a life expectancy that is reduced by 10 years and the disease is estimated to affect about 550 million people worldwide by 2030 (Johnson et al., 2009; Chatterjee et al., 2017; Rowley et al., 2017). Exenatide (EXT), the synthetic exendin-4, is an outstanding incretin mimetic that is approved by the Food and Drug Administration and the European Medicines Agency as the drug for type 2 diabetes (Deacon, 2004; Davidson et al., 2005; Song et al., 2019). It has multiple glucose regulatory therapeutic effects, such as enhancement of insulin secretion, reduction of food intake, and deceleration of gastric emptying (Li et al., 2015; Song et al., 2019). However, EXT only has a short plasma half-life of 2.4 h and an action time of about 8 h, thus the long-acting EXT formulations are of prime importance (DeYoung et al., 2011; Cai et al., 2013).
Poly(d,l-lactic-co-glycolic acid) (PLGA) microspheres are an outstanding material for implanting long-acting drug release characteristics safely, reliably, and efficiently (Danhier et al., 2012; Wu et al., 2017; Qi et al., 2019; Zhai et al., 2020). The only long-acting product of EXT on the market (Bydureon®, once-weekly subcutaneous injection) is produced by using PLGA microspheres (Scheen, 2014). However, the side effects remained as the pharmacokinetic profile shows a delayed-release or lag phase (Nikou et al., 2005). After an initial burst in the first 2 days after administration of Bydureon®, the drug is not released again for 2 weeks and it then takes up to 7 weeks for complete drug release (Cai et al., 2013). These 2 weeks lag phase leads to poor pharmacokinetics and diminished efficacy which seriously limits its clinical applications. An optimal long-acting drug delivery system should have a reasonable release profile which exhibits a low initial release followed by a continuous release phase (Ruan et al., 2018; Wang et al., 2019b). New strategies are needed to improve the sustained-release characteristics of current EXT-loaded PLGA microspheres.
For water-soluble peptides loaded PLGA microspheres such as EXT (Li et al., 2013), water in oil (W/O) emulsions and water water-in-oil-in-water (W1/O/W2) emulsions are the most used preparation methods (Qi et al., 2014). The W1/O/W2 emulsion method has many advantages over the simple emulsion method for the microsphere preparation, such as entrapment of hydrophilic peptides, prevention of drug degradation, controllable rate, enhanced encapsulation efficiency (EE), and drug loading capacity (Mao et al., 2007; Mundargi et al., 2007; Wang et al., 2019a). Thus, W1/O/W2 method has been widely used to encapsulate hydrophilic protein and peptides in PLGA microspheres. Drug diffusion and polymer erosion are the critical factors in controlling drug release from PLGA microspheres (Ruan et al., 2018). Generally speaking, the initial phase of drug release is controlled by drug diffusion from the surface and the later phase (the lag and second drug release phase) occurs through erosion (Zolnik & Burgess, 2008; Gu et al., 2016). The peptide or protein are usually water soluble, which will lead to aggregates near the surface of microspheres that are prepared via W1/O/W2 emulsions (Leo et al., 1998). This solubility enables the rapid diffusion of drugs from the surface of microspheres in the initial phase. In the later phase, erosion leads to the formation of pores and drugs encapsulated inside the PLGA matrix begin to slowly diffuse through water-filled channels as polymer degradation (Fredenberg et al., 2011). Thus, this ‘outside-in’ pattern of porosity progression in the erosion process explains the lag phase observed in PLGA microspheres. The length of the lag phase depends on the time required for the entire microsphere to become porous. The occurrence of drug release after the lag phase appears to be the result of swelling of the microsphere following pore formation (Gasmi et al., 2016; Gu et al., 2016; Wang et al., 2019b). Therefore, porous microspheres minimize the lag phase by skipping the initial erosion phase which forming pores. However, incorporated drugs released rapidly during the initial phase caused by the highly porous of these microspheres (Kim et al., 2006).
Inner porous microspheres with an outer thin layer are expected to achieve the desirable release behavior of drugs, because the outside-layer blocks out routes of drug diffusion through pores in the initial phase, thereby reducing burst release. Besides, inside-porous microspheres owned larger porous surface and inter-sphere space rooms than nonporous microspheres that allow them to incorporate more drugs (Kim et al., 2012; Wei et al., 2016; Ni et al., 2017; Yang et al., 2019). Kim et al. (2011a,b) fabricated porous PLGA microspheres for pulmonary delivery of EXT, they used palmityl-acylated EXT or albumin coated surface to reduce burst release caused by open-pores surfaces of porous microspheres.
In this study, we developed a microfluidic process for the preparation of EXT-loaded inside-porous PLGA microspheres with thin outside-layers based on W1/O/W2 emulsions (Scheme 1). We studied the release characteristics of EXT-PMS with various pore sizes which demonstrated that porosity is a determining factor of the later stage drug release. In addition, we investigated the potential influence of PLGA concentration, EXT concentration, and ratio of oil-to-water phase on the in vitro dissolution curves of EXT-PMS. In vivo pharmacokinetics studies in rats of EXT-PMS showed stable and sustained release of EXT with no delayed release and low burst release. With this approach, we seek to provide a simple and effective method for improving an existing long-acting dosage form that may potentially be used with other drugs.
Scheme 1.
Schematic of the synthetic process for the EXT-loaded inside-porous PLGA microspheres.
2. Material and methods
2.1. Chemical materials
Exenatide was purchased from Jianyuan Pharmaceutical Technology Co., Ltd. (Shenzhen China). Poly(vinyl alcohol) 210 (PVA), sodium azide, and sodium dodecyl sulfate (SDS) were obtained from Aladdin Bio-Chem Technology Co., Ltd. (Shanghai, China). PLGA (85/15) (lactic acid (LA)/glycolic acid (GA) = 85/15, Mw = 50,000), PLGA (75/25) (LA/GA= 75/25, Mw = 50,000), and PLGA (50/50) (LA/GA = 50/50, Mw = 50,000) were all purchased from Shandong Academy of Pharmaceutical Sciences (Pilot Plant; Jinan, China). Micro-BCA kit was supplied by Shenggong Biological Engineering Co. Ltd. (Shanghai, China). Rhodamine 123 (Rh123) was supplied by Shanghai Yuanye Bio-technology Co., Ltd. (Shanghai, China). Dichloromethane (DCM), NH4HCO3, and dimethyl carbonate (DMC) were all purchased from Damao Chemical Reagent Factory (Tianjin, China). All chemicals and reagents were analytical reagent grade.
2.2. Preparation of EXT-loaded PLGA microspheres
A water-in-oil-in-water (W1/O/W2) emulsion method was used to prepare EXT-PMS. The oil phase was a PLGA/DCM solution that was prepared by dissolving PLGA in DCM. The water phase 1 was prepared by dissolution of EXT and NH4HCO3 in an aqueous solution. The two phases were mixed and emulsified by sonication at 0 °C to form the W1/O emulsion. Then, W1/O emulsion internal phase was mixed with the external phase or water phase 2 containing PVA and NH4HCO3 in an aqueous solution through the microfluidic cross chip. PLGA microspheres were solidified after stirring to volatize the organic solvent. The microspheres were centrifuged at 8000 r/min and harvested, thoroughly washed with distilled water and freeze-dried.
EXT-MS were also prepared using a W1/O/W2 emulsion method with a microfluidic technique. Specifically, the water phase 1 was prepared by dissolution of EXT in water. The oil phase was prepared by dissolving PLGA in DCM. The water phase 1 and oil phase were mixed and emulsified by sonication to form the W1/O emulsion. Then, W1/O emulsions were mixed with the water phase 2 which containing PVA through the microfluidic cross chip to form W1/O/W2 emulsions. PLGA microspheres were solidified after stirring to volatilize the organic solvent. The microspheres were centrifuged at 8000 r/min and harvested, thoroughly washed with distilled water and freeze-dried.
We used a single-factor approach to optimize the composition and synthesis process of the microspheres. The polymer type, PLGA concentration, drug concentration, W1 to O ratio, and porogen concentration were each tested to obtain the optimal microsphere formulation. The drug-loading capacity (DLC), EE, and in vitro cumulative release curve were selected as the inspection index.
2.3. Size distribution measurement
The average diameter and Span value for the microspheres were calculated using data measured from 200 particles observed using a CX22 optical microscope (Olympus, Tokyo, Japan). The particle size distribution was evaluated by the Span value, which was calculated using the following equation:
(1) |
where D90, D10, and D50 are the average particle diameters of particles accounting for 90, 10, and 50% of all particles, respectively.
2.4. Scanning electron microscopy
Scanning electron microscopy (SEM) was performed using a G5 ProX-SE microscope (Carle Zeiss, Oberkochen, Germany). Microspheres with dried using infrared light, and then dry powders of microspheres were dispersed on carbon tape and coated with gold.
2.5. Confocal laser scanning microscopy
Features of the microspheres were observed using confocal laser scanning microscopy (CLSM) (Carle Zeiss, Oberkochen, Germany). Before observation, microspheres were suspended in water and fixed on a glass slide.
2.6. Differential scanning calorimetry
Differential scanning calorimetry (DSC) was carried out by using a DSC analyzer (PerkinElmer). Briefly, 10 mg samples were placed in an aluminum pan and heated from 20 °C to 200 °C at a rate 10 °C/min.
2.7. Encapsulated efficiency and drug loading
Ten milligrams of EXT-PMS or EXT-MS microspheres were added to 1 mL of 0.1 M NaOH solution (containing 5% SDS) and vibrated (100 r/min, 37 °C) for 24 h to dissolve EXT. The supernatant fluid (containing EXT) was obtained by centrifugation (8000 rpm, 10 min) and the EXT concentration was measured by micro-BCA kit. The linear range was from 2 to 40 μg/mL (r = 0.9997). Encapsulated efficiency and drug loading were calculated with the following equations:
(2) |
(3) |
2.8. In vitro dissolution testing
Twenty milligrams of EXT-PMS microspheres were dispersed in 500 mL dissolution medium composed of 10 mM phosphate-buffered saline buffer and 0.01% sodium azide at pH 7.4. The dissolution medium was shaken at a rate of 100 r/min (37 °C ± 0.5 °C). One mL sample was collected at 1, 3, 5, 7, 14, 21, 28, and 35 days separately. At each collection, 1 mL blank dissolution medium was added back to maintain the volume at 500 mL.
2.9. Pharmacokinetic analysis
Male Sprague-Dawley (SD) rats weighing 200 ± 20 g were purchased from the Experimental Animal Center of Southern Medical University (Guangzhou, China) and were housed in the Experimental Animal Center of Guangzhou University of Chinese Medicine under room temperature, with moderate humidity 50–60% humidity and a 12-h day/night cycle. All animal experimental procedures were approved by the Animal Ethics Committee at the Experimental Animal Center of Guangzhou University of Chinese Medicine. Rats were kept under fasting conditions with free access to water for 12 h prior to initiation of the experiment.
Nine rats were randomly divided into two groups (n = 3). A group was administered subcutaneous injections of either EXT-PMS suspension (100 mg/kg) or EXT-MS suspension (100 mg/kg). Blood samples were collected at 0.5, 1, 2, 4, 6, 8 h, and 1, 4, 7,10, 14, 18, 22, 26, 30, 34, 38 days after administration. Plasma samples were obtained by centrifuging at 3000 × g for 15 min at 2–8 °C and were stored at −20 °C before analysis. All pharmacokinetic parameters were analyzed by DAS3.2 software (Chinese Pharmacological Society, China). Plasma concentration at each time point was reported as the mean ± standard deviation.
3. Results and discussion
We investigated the effects of polymer type, PLGA concentration, drug concentration, W1 to O ratio, and porogen concentration on the DLC, EE, and in vitro dissolution curve of the EXT-PMS. These factors are thought to influence the uniformity and ideal in vivo release characteristics.
3.1. Effect of polymer
PLGA is a copolymer of LA and GA. As a consequence of the presence of methyl side groups in LA, PLGA with a higher content of GA are more hydrophilic, absorbs more water and subsequently degrades more quickly and thus may affect the release characteristic of EXT (Zheng & Liang, 2010; Zhang et al., 2016). Thus, to find a suitable polymer, we investigated the influence of PLGA composition on the properties of EXT-PMS. PLGA (50/50), PLGA (75/25), and PLGA (85/15) which consists of 50, 25, and 15% of GA, respectively, were used to synthesis EXT-PMS. Microspheres prepared by PLGA (50/50) showed slightly higher encapsulation efficiency (EE) and DLC than its 85/15 and 75/25 counterparts (Supplementary Figure S1). This difference may due to the enhanced hydrophilic interaction between PLGA (50/50) and the water-soluble EXT, compared to the other two polymers (Gentile et al., 2014). There is no obvious difference of in vitro dissolution curve between these microspheres prepared by different polymers (Supplementary Figure S2).
According to previous studies, PLGA concentration played a crucial role in EE and DLC properties. To further improve EE and DLC of microspheres, we increased the concentration of PLGA (50/50) from 20 to 100 mg/mL. As shown in Figure 1(A), the higher polymer concentration clearly enhanced EE from 73 to 89% and had negligible effects on DLC. This may be due to the low polymer concentration easily causing leakage of EXT (Qi et al., 2013). Meanwhile, the higher PLGA concentration had a significantly lower burst release and continued having drug available for release on day 35 (Figure 1(B)). These improvements are due to the increased density of the microspheres caused by higher PLGA concentration, which may help to incorporate more drug and slow down the degradation (Tinsley-Bown et al., 2000).
Figure 1.
(A) Encapsulation efficiency and drug-loading capacity of EXT-PMS prepared by using different PLGA (50/50) concentrations. (B) Cumulative release of EXT from EXT-PMS prepared by using different PLGA (50/50) concentration (mg/mL). (C) Drug-loading capacity and encapsulation efficiency of EXT-PMS prepared by using different mass ratio of EXT to PLGA. (D) Cumulative release of EXT from EXT-PMS prepared by using different mass ratio of EXT to PLGA. (E) Drug-loading capacity and encapsulation efficiency of EXT-PMS prepared by using different volume ratio of oil to W1 phase. (F) Cumulative release of EXT from EXT-PMS prepared by using different volume ratio of oil to W1 phase.
3.2. Effect of the proportion of drug and oil phase
To improve the drug content of porous microspheres, prolong the sustained-release period and reduce administration times, we increased the mass proportion of EXT in the preparation process of EXT-PMS. From Figure 1(A,B), we concluded that 100 mg/mL of PLGA is the optimal concentration. Under this optimized PLGA concentration, we investigated the effects of mass ratio of EXT to PLGA on DLC, EE, and in vitro dissolution curve of EXT-PMS. For mass ratio of EXT to PLGA under 1:20, 1:15, 1:10, 1:5, and 1:2.5, the corresponding EXT concentration is 5, 6.78, 10, 20, and 40 mg/mL, respectively. As shown in Figure 1(C), the DLC was three times higher and EE was 50% lower when the mass ratio of EXT to PLGA (EXT/PLGA) increased from 1:20 to 1:2.5 gradually. For in vitro release curve (Figure 1(D)), EXT-PMS prepared with the ratio of 1:2.5 released almost 90% EXT on the first day, which exhibited extremely high burst release than that of 1:20. When the ratio of EXT/PLGA was maintained between at 1:15 (corresponding to 6.78 mg/mL of EXT), the resulting EXT-PMS did not display any burst release, as shown by the “S-shaped” dissolution curve. This may be explained by the increased osmotic pressure in W1 phase caused by the addition of large amounts of drugs. According to a previous study, the increased osmotic pressure between W1 and W2 could prevent the influx of the W1 phase into the W2 phase and reduced the formation of water channels which could have led to a high initial burst (Yeo & Park, 2004).
Furthermore, the proportion of oil phase also could change the density of microspheres and affecting the release behavior of drugs, so the O/W1 volume ratio was investigated in the system. Compared with higher ratios of oil to W1 phase, the 10:1 and 10:2 ratio of O/W1 group exhibited a slightly higher DLC and EE. These two groups also released less than 20% of EXT on the first day and there was no delayed drug release over the next 4 weeks (Figure 1(E,F)). However, once the proportion of W1 phase is higher than 10:3, almost half of EXT was released in the initial release period. The reason is that the increased W1 phase ratio and reduced O phase ratio resulting in a relatively loose structure inside the microsphere and eventually a higher burst release.
We selected an optimal formulation with a 1:15 ratio of EXT/PLGA (50/50) and 10:1 ratio of O/W1. Results of subsequent analyses described below have these characteristics unless otherwise specified.
3.3. Effect of the porogen concentration
As mentioned earlier, the formation of pores in nonporous microspheres mainly controls the time of the lag phase. In porous microspheres, the size and number of pores are affected by the porogen concentration (Bae et al., 2009). NH4HCO3 is a commonly used porogen. NH4HCO3 breaks down during the emulsification process into NH3, CO2, and O2 and as these gases volatize, the space they occupied form pores in the drying and solidification process (Thanh et al., 2016). Thus, we carefully investigated how the concentration of NH4NCO3 affecting the characters of porous PLGA microspheres and release behaviors of drugs. As the proportion of NH4HCO3 increased to 10%, both the DLC and EE were reduced by about 21% compared with EXT-PMS using 2% (Figure 2(A)). Notably, EXT-PMS produced using 2% porogens continued exhibiting delayed-release characteristics (Figure 2(F)). However, EXT-PMS using 8 and 10% NH4HCO3 showed about 40% release on the first day. In particular, EXT-PMS produced with 6% NH4HCO3 displayed steady release for 35 days and low burst release on the first day. These results strongly demonstrated that variations in the porogen concentration can accelerate the release of EXT or other drugs in the initial phase. The difference in drug release between these EXT-PMS produced from different NH4HCO3 concentrations can be explained by the different shortened diffusion pathways attributed by large pore sizes inside of the microspheres. Large pores which were caused by NH4HCO3 could shorten diffusion paths both in the initial phase and later phase, thus EXT-PMS using 8 and 10% NH4HCO3 exhibited high initial release. After the initial release, the time needed to be released any drugs trapped inside the microspheres are also determined by the length of these pathways. EXT-PMS prepared with low concentration NH4HCO3 of 2% was not significantly improved the lag phase after the initial phase. As a result, EXT-PMS produced from 6% NH4HCO3 released EXT stable in the initial phase and more rapidly in the later phase.
Figure 2.
(A) Drug-loading capacity and encapsulation efficiency of EXT-PMS prepared by using different proportion of NH4HCO3 (%). (B) Cumulative release of EXT from EXT-PMS prepared by using different proportion of NH4HCO3 (%).
Based on the results of our optimization tests, we concluded that 100 mg/mL of PLGA with LA/GA ratio of 50/50, a 1:15 ratio of EXT to PLGA, a 10:2 ratio of O/W1 and 6% concentration of NH4HCO3 porogen, is the preferred formulations that can produce EXT-PMS with desirable in vitro dissolution characteristics (Table 1).
Table 1.
The optimized formulation of EXT-PMS.
Polymer type (LA/GA) | Polymer concentration (mg/mL) | Mass ratio of drug to polymer | Volume ratio of oil to W1 phase | Proportion of NH4HCO3 (%) |
---|---|---|---|---|
PLGA (50:50) | 100 | 1:15 | 10:2 | 6 |
GA: glycolic acid; LA: lactic acid.
3.4. Characterization of microspheres
The crystallization information of EXT in microspheres was determined by DSC analysis (Figure 3(A)). Pure EXT had a broad endothermic peak at 68 °C and a narrow endothermic peak at 145 °C, which is consistent with the literature reports. PLGA (50/50) did not show any obvious absorption peak. EXT-PMS also showed an endothermic peak at 145 °C. These data proved the existence of EXT in microspheres. To certify the porous structure of EXT-PMS, the distribution of EXT within porous microspheres was observed by CLSM. Fluorescent EXT-loaded inside-porous PLGA microspheres (F-EXT-PMS) were obtained by encapsulated Rh123 with the same protocol of EXT-PMS. As illustrated in Figure 3(B), the green fluorescence only appeared at the surface of microspheres forming a thin circle outside, but not internally. In addition, the surface and inner morphologies of EXT-PMS were observed by SEM. Images revealed the smooth surface and internal network structure. With statistical calculation, the average diameter of EXT-PMS was 85 μm. These microspheres exhibited 95 pores and a porosity of 1.5–10 μm with the median of 6 μm (Figure 3(C,D)). These data demonstrated that the obtained EXT-PMS has numerous pores inside and smooth surfaces.
Figure 3.
(A) DSC thermograms of EXT-PMS, PLGA (50/50) and EXT. (B) CLSM images of F-EXT-PMS. (C) SEM images of surface of EXT-PMS. (D) SEM images of internal structure of EXT-PMS.
3.5. Pharmacokinetics study
Inspired by the superior in vitro dissolution results of EXT-PMS, we further carried out pharmacokinetic experiments of them. Twelve SD rats were divided into two groups and were subcutaneously injected with either EXT-PMS or EXT-MS. The EXT plasma concentration after administration is shown in Figure 4 and a summary of the main pharmacokinetics parameters is provided in Table 2. EXT plasma concentration of rats treated with EXT-PMS showed similar burst release level with EXT-MS. Especially, EXT could be continuous release without a lag phase in 14 days. However, EXT-MS treated group showed obviously lag phase that only released EXT with effective concentration after day 15. In addition, The AUC0-1 and AUC0-38 values of EXT-PMS were 27.14 and 293.4 ng/mL·h. For EXT-MS, the AUC0-1 and AUC0-38 values were 23.23 and 326.17 ng/mL·h, respectively. Furthermore, we performed a significant test for data in Table 2. As shown, the parameters of Cmax and Tmax showed significant difference (p < 0.01) and the AUC0-38 and AUC0-1 showed no obvious difference. The significant differences between Tmax and Cmax, and plasma concentration–time curves of EXT-PMS and EXT-MS both demonstrated the rapid and sustained release property of EXT-PMS without delayed-release in vivo. In addition, the no significant difference between AUC0-38 and AUC0-1 illustrated that the bioavailability of EXT-PMS is as good as EXT-MS. These data demonstrated that the prepared EXT-PMS showed improved release characteristics without a lag phase, compared to EXT-MS. Long-term therapeutic effects were also observed which are consistent with in vitro result of EXT-PMS.
Figure 4.
Plasma concentration–time curves of EXT-MS or EXT-PMS following subcutaneous administration in SD rats.
Table 2.
The pharmacokinetic parameters of EXT-PMS.
Parameter | EXT-PMS | EXT-MS |
---|---|---|
AUC0–38 (ng·mL−1·day) | 293.4 ± 28.12 | 326.17 ± 50.84 |
AUC0–1 (ng·mL−1·day) | 27.14 ± 1.92 | 23.23 ± 2.96 |
Cmax (ng·mL−1) | 46.05 ± 6.39** | 37.00 ± 1.98 |
Tmax (h) | 2** | 4 |
**p < .01.
Generally, the effect of a drug is determined directly by the drug concentration at the site of action (more specifically, by the drug’s binding with a receptor) (Holford & Sheiner, 1981; Sheiner & Steimer, 2000; Tozer & Rowland, 2006). Due to the importance of the concentration and its decisive effect on drug efficacy, many pharmacokinetics studies can focus on improving the release behaviors without further testing the pharmacodynamic properties. Thus, for a specific drug, like EXT in this study, the blood concentration is a quite important factor which can also reflect the drug effect. The EXT-PMS showed the rapid release of the drugs in the initial phase and could maintain effective concentration, which is the biggest advantage over other EXT-MS dosage forms with delay-release properties.
4. Conclusion
In this study, the EXT-loaded PLGA microspheres were effectively fabricated by W1/O/W2 emulsion microfluidic method. The effects of various polymer type, PLGA concentration, proportion of drug and oil phase, and especially the porogen concentration on the release behaviors of EXT-PMS were studied in the system. Characterizations demonstrated the internal large pores and the external thin layer structure of EXT-PMS. Both in vitro and in vivo experiments validated the ability of our formulation of EXT-PMS to release drugs rapidly in the initial phase and to maintain effective concentration without delay-release for 30 days. The resulting inside-porous microspheres could sustain the release of EXT and offer the dual-advantage of (i) absence of a lag phase and (ii) low burst release. To the best of our knowledge, this is the first work to improve the release profile of EXT by inside-porous PLGA microspheres. Our method indicates the great potential for these inside-porous microspheres in the development of long-acting drug delivery systems with reasonable release profiles for various drugs.
Funding Statement
This work was financially supported by the Science and Technology Program of Guangzhou, China [201604020166].
Supporting information
Supporting Information is available free of charge. Drug-loading capacity and encapsulation efficiency of EXT-PMS prepared by different PLGA polymer; in vitro dissolution of EXT-PMS prepared by different PLGA polymer.
Disclosure statement
There are no conflicts of interest to declare.
References
- Bae SE, Son JS, Park K, Han DK. (2009). Fabrication of covered porous PLGA microspheres using hydrogen peroxide for controlled drug delivery and regenerative medicine. J Control Release 133:37–43. [DOI] [PubMed] [Google Scholar]
- Cai Y, Wei L, Ma L, et al. (2013). Long-acting preparations of exenatide. Drug Des Devel Ther 7:963–70. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chatterjee S, Khunti K, Davies MJ. (2017). Type 2 diabetes. The Lancet 389:2239–51. [DOI] [PubMed] [Google Scholar]
- Danhier F, Ansorena E, Silva JM, et al. (2012). PLGA-based nanoparticles: an overview of biomedical applications. J Control Release 161:505–22. [DOI] [PubMed] [Google Scholar]
- Davidson MB, Bate G, Kirkpatrick P. (2005). Exenatide. Nat Rev Drug Discov 4:713–4. [DOI] [PubMed] [Google Scholar]
- Deacon CF. (2004). Therapeutic strategies based on glucagon-like peptide 1. Diabetes 53:2181–9. [DOI] [PubMed] [Google Scholar]
- DeYoung MB, MacConell L, Sarin V, et al. (2011). Encapsulation of exenatide in poly-(D, L-lactide-co-glycolide) microspheres produced an investigational long-acting once-weekly formulation for type 2 diabetes. Diabetes Technol Ther 13:1145–54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fredenberg S, Wahlgren M, Reslow M, Axelsson A. (2011). The mechanisms of drug release in poly(lactic-co-glycolic acid)-based drug delivery systems-a review. Int J Pharm 415:34–52. [DOI] [PubMed] [Google Scholar]
- Gasmi H, Siepmann F, Hamoudi M, et al. (2016). Towards a better understanding of the different release phases from PLGA microparticles: dexamethasone-loaded systems. Int J Pharm 514:189–99. [DOI] [PubMed] [Google Scholar]
- Gentile P, Chiono V, Carmagnola I, Hatton PV. (2014). An overview of poly(lactic-co-glycolic) acid (PLGA)-based biomaterials for bone tissue engineering. Int J Mol Sci 15:3640–59. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gu B, Sun X, Papadimitrakopoulos F, Burgess DJ. (2016). Seeing is believing, PLGA microsphere degradation revealed in PLGA microsphere/PVA hydrogel composites. J Control Release 228:170–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Holford NH, Sheiner LB. (1981). Understanding the dose-effect relationship: clinical application of pharmacokinetic-pharmacodynamic models. Clin Pharmacokinet 6:429–53. [DOI] [PubMed] [Google Scholar]
- Johnson RJ, Perez-Pozo SE, Sautin YY, et al. (2009). Hypothesis: could excessive fructose intake and uric acid cause type 2 diabetes? Endocr Rev 30:96–116. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim I, Byeon HJ, Kim TH, et al. (2012). Doxorubicin-loaded highly porous large PLGA microparticles as a sustained- release inhalation system for the treatment of metastatic lung cancer . Biomaterials 33:5574–83. [DOI] [PubMed] [Google Scholar]
- Kim HK, Chung HJ, Park TG. (2006). Biodegradable polymeric microspheres with “open/closed” pores for sustained release of human growth hormone. J Control Release 112:167–74. [DOI] [PubMed] [Google Scholar]
- Kim H, Lee J, Kim TH, et al. (2011. a). Albumin-coated porous hollow poly(lactic-co-glycolic acid) microparticles bound with palmityl-acylated exendin-4 as a long-acting inhalation delivery system for the treatment of diabetes. Pharm Res 28:2008–19. [DOI] [PubMed] [Google Scholar]
- Kim H, Park H, Lee J, et al. (2011. b). Highly porous large poly(lactic-co-glycolic acid) microspheres adsorbed with palmityl-acylated exendin-4 as a long-acting inhalation system for treating diabetes. Biomaterials 32:1685–93. [DOI] [PubMed] [Google Scholar]
- Leo E, Pecquet S, Rojas J, et al. (1998). Changing the pH of the external aqueous phase may modulate protein entrapment and delivery from poly(lactide-co-glycolide) microspheres prepared by a w/o/w solvent evaporation method. J Microencapsul 15:421–30. [DOI] [PubMed] [Google Scholar]
- Li K, Yu L, Liu X, et al. (2013). A long-acting formulation of a polypeptide drug exenatide in treatment of diabetes using an injectable block copolymer hydrogel. Biomaterials 34:2834–42. [DOI] [PubMed] [Google Scholar]
- Li X, Zhao Z, Li L, et al. (2015). Pharmacokinetics, in vitro and in vivo correlation, and efficacy of exenatide microspheres in diabetic rats. Drug Deliv 22:86–93. [DOI] [PubMed] [Google Scholar]
- Mao S, Xu J, Cai C, et al. (2007). Effect of WOW process parameters on morphology and burst release of FITC-dextran loaded PLGA microspheres. Int J Pharm 334:137–48. [DOI] [PubMed] [Google Scholar]
- Mundargi RC, Srirangarajan S, Agnihotri SA, et al. (2007). Development and evaluation of novel biodegradable microspheres based on poly(d,l-lactide-co-glycolide) and poly(epsilon-caprolactone) for controlled delivery of doxycycline in the treatment of human periodontal pocket: in vitro and in vivo studies. J Control Release 119:59–68. [DOI] [PubMed] [Google Scholar]
- Ni R, Muenster U, Zhao J, et al. (2017). Exploring polyvinylpyrrolidone in the engineering of large porous PLGA microparticles via single emulsion method with tunable sustained release in the lung: in vitro and in vivo characterization. J Control Release 249:11–22. [DOI] [PubMed] [Google Scholar]
- Nikou KN, Stivaktakis N, Avgoustakis K, et al. (2005). A HER-2/neu peptide admixed with PLA microspheres induces a Th1-biased immune response in mice. Biochim Biophys Acta 1725:182–9. [DOI] [PubMed] [Google Scholar]
- Qi P, Bu R, Zhang H, et al. (2019). Goserelin acetate loaded poloxamer hydrogel in PLGA microspheres: core-shell di-depot intramuscular sustained release delivery system. Mol Pharm 16:3502–13. [DOI] [PubMed] [Google Scholar]
- Qi F, Wu J, Fan Q, et al. (2013). Preparation of uniform-sized exenatide-loaded PLGA microspheres as long-effective release system with high encapsulation efficiency and bio-stability. Colloids Surf B Biointerf 112:492–8. [DOI] [PubMed] [Google Scholar]
- Qi F, Wu J, Yang T, et al. (2014). Mechanistic studies for monodisperse exenatide-loaded PLGA microspheres prepared by different methods based on SPG membrane emulsification. Acta Biomater 10:4247–56. [DOI] [PubMed] [Google Scholar]
- Rowley WR, Bezold C, Arikan Y, et al. (2017). Diabetes 2030: insights from yesterday, today, and future trends. Popul Health Manag 20:6–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ruan S, Gu Y, Liu B, et al. (2018). Long-acting release microspheres containing novel GLP-1 analog as an antidiabetic system. Mol Pharm 15:2857–69. [DOI] [PubMed] [Google Scholar]
- Scheen A. (2014). Bydureon: first once weekly GLP-1 receptor agonist (exenatide LAR). Rev Med Liege 69:214–9. [PubMed] [Google Scholar]
- Sheiner LB, Steimer JL. (2000). Pharmacokinetic/pharmacodynamic modeling in drug development. Annu Rev Pharmacol Toxicol 40:67–95. [DOI] [PubMed] [Google Scholar]
- Song Y, Shi Y, Zhang L, et al. (2019). Synthesis of CSK-DEX-PLGA nanoparticles for the oral delivery of exenatide to improve its mucus penetration and intestinal absorption. Mol Pharm 16:518–32. [DOI] [PubMed] [Google Scholar]
- Thanh DTM, Trang PTT, Thom NT, et al. (2016). Effects of porogen on structure and properties of poly lactic acid/hydroxyapatite nanocomposites (PLA/HAp). J Nanosci Nanotechnol 16:9450–9. [Google Scholar]
- Tinsley-Bown AM, Fretwell R, Dowsett AB, et al. (2000). Formulation of poly (D, L-lactic-co-glycolic acid) microparticles for rapid plasmid DNA delivery. J Control Release 66:229–41. [DOI] [PubMed] [Google Scholar]
- Tozer TN, Rowland M.. 2006. Introduction to pharmacokinetics and pharmacodynamics: the quantitative basis of drug therapy. Philadelphia, PA: Lippincott Williams & Wilkins. [Google Scholar]
- Wang J, Wang Y, Wang Z, et al. (2019. a). A thermosensitive gel based on w1/o/w2 multiple microemulsions for the vaginal delivery of small nucleic acid. Drug Deliv 26:168–78. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang T, Xue P, Wang A, et al. (2019. b). Pore change during degradation of octreotide acetate-loaded PLGA microspheres: The effect of polymer blends. Eur J Pharm Sci 138:104990. [DOI] [PubMed] [Google Scholar]
- Wei Y, Wang Y, Zhang H, et al. (2016). A novel strategy for the preparation of porous microspheres and its application in peptide drug loading. J Colloid Interface Sci 478:46–53. [DOI] [PubMed] [Google Scholar]
- Wu J-Z, Williams GR, Li H-Y, et al. (2017). Insulin-loaded PLGA microspheres for glucose-responsive release. Drug Deliv 24:1513–25. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yang Y, Huang Z, Li J, et al. (2019). PLGA porous microspheres dry powders for codelivery of afatinib‐loaded solid lipid nanoparticles and paclitaxel: novel therapy for EGFR tyrosine kinase inhibitors resistant nonsmall cell lung cancer. Adv Healthcare Mater 8:1900965. [DOI] [PubMed] [Google Scholar]
- Yeo Y, Park K. (2004). Control of encapsulation efficiency and initial burst in polymeric microparticle systems. Arch Pharm Res 27:1–12. [DOI] [PubMed] [Google Scholar]
- Zhai J, Wang Y-e, Zhou X, et al. (2020). Long-term sustained release poly(lactic-co-glycolic acid) microspheres of asenapine maleate with improved bioavailability for chronic neuropsychiatric diseases . Drug Deliv 27:1283–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang Y, Wischke C, Mittal S, et al. (2016). Design of controlled release PLGA microspheres for hydrophobic fenretinide. Mol Pharm 13:2622–30. [DOI] [PubMed] [Google Scholar]
- Zheng C, Liang W. (2010). A one-step modified method to reduce the burst initial release from PLGA microspheres. Drug Deliv 17:77–82. [DOI] [PubMed] [Google Scholar]
- Zolnik BS, Burgess DJ. (2008). Evaluation of in vivo-in vitro release of dexamethasone from PLGA microspheres. J Control Release 127:137–45. [DOI] [PubMed] [Google Scholar]