Skip to main content
BMC Oral Health logoLink to BMC Oral Health
. 2021 Feb 16;21:71. doi: 10.1186/s12903-021-01424-3

Three-dimensional assessment of the anterior and inferior loop of the inferior alveolar nerve using computed tomography images in patients with and without mandibular asymmetry

Jae-Young Kim 1, Michael D Han 2, Kug Jin Jeon 3, Jong-Ki Huh 1, Kwang-Ho Park 1,
PMCID: PMC7885493  PMID: 33593343

Abstract

Background

The purpose of this study was to investigate the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry.

Method

Preoperative computed tomography images of patients who had undergone orthognathic surgery from January 2016 to December 2018 at a single institution were analyzed. Subjects were classified into two groups as “Asymmetry group” and “Symmetry group”. The distance from the most anterior and most inferior points of the ALIAN (IANant and IANinf) to the vertical and horizontal reference planes were measured (dAnt and dInf). The distance from IANant and IANinf to the mental foramen were also calculated (dAnt_MF and dInf_MF). The length of the mandibular body and symphysis area were measured. All measurements were analyzed using 3D analysis software.

Results

There were 57 total eligible subjects. In the Asymmetry group, dAnt and dAnt_MF on the non-deviated side were significantly longer than the deviated side (p < 0.001). dInf_MF on the non-deviated side was also significantly longer than the deviated side (p = 0.001). Mandibular body length was significantly longer on the non-deviated side (p < 0.001). There was no significant difference in length in the symphysis area (p = 0.623). In the Symmetry group, there was no difference between the left and right sides for all variables.

Conclusion

In asymmetric patients, there is a difference tendency in the ALIAN between the deviated and non-deviated sides. In patients with mandibular asymmetry, this should be considered during surgery in the anterior mandible.

Keywords: Facial asymmetry, Inferior alveolar nerve, Three-dimensional analysis, Computed tomography

Background

The inferior alveolar nerve (IAN) travels through the mandibular canal and innervates the lower lip, chin, mandibular teeth and the anterior gingiva and alveolar mucosa. The last part of the IAN runs anterior and inferior to the mental foramen and forms an anterior loop. It has been reported that an anterior loop of the inferior alveolar nerve (ALIAN) can be observed in about 40–94% of cases [14].

For this reason, iatrogenic damage of the IAN can occur during procedures such as genioplasty, implant surgery near the mental foramen, IAN lateralization, and open reduction and internal fixation of fractures. According to previous studies, IAN damage has been reported to be 17–38% after genioplasty [57]. Hwang et al. recommended the level of a genioplasty osteotomy be at least 4.5 mm below the mental foramen to avoid iatrogenic damage [8]. For dental implant surgery, a 4–6 mm safety margin from the anterior border of mental foramen has been recommended [2, 9]. However, Filo et al. reported that it is difficult to provide a guideline for the safety margin due to varying lengths of the anterior loop [10].

Several authors have reported differences in the inferior alveolar nerve in facial asymmetry on the deviated and non-deviated sides [11, 12]. Yoon et al. reported that both the anterior and inferior of the ALIAN are longer in mandibular prognathism than in mandibular retrognathism [13].They also concluded that the length of the anterior loop can increase as the mandibular subunit becomes longer [13]. In this regard, variations may exist in the ALIAN in asymmetric mandibles, which may warrant different safety margins bilaterally.

The purpose of this study was to investigate the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry.

Methods

Subjects

Records of patients who underwent a computed tomography (CT) scan and orthognathic surgery from January 2016 to December 2018 in the Department of Oral and Maxillofacial Surgery at Gangnam Severance Hospital were reviewed in this retrospective study. Patients with missing maxillary first molar or mandibular central or lateral incisor, cleft lip and palate, history of mandibular trauma affecting the body or ramus length, or lateral chin deviation of 2.5–3.5 mm on CT analysis were excluded. CT images were obtained with a CT scanner (Siemens definition AS+, Siemens, Germany) by following parameters: 1-mm slice thickness, 7-s scan time, 120 kV, and 90 mAs. Those whose CT scans lacked clearly identifiable mandibular canals were also excluded.

This study was approved by the institutional review board (IRB) of Gangnam Severance Hospital (approval No. #3-2019-0236) and complied with the tenets of the Declaration of Helsinki. Written or verbal informed consent was waived by the IRB of Gangnam Severance Hospital, as this study had a retrospective design and all data were analyzed anonymously.

Reference points and planes

Reference points and planes were summarized in Table 1. All landmarks and reference planes were identified using multiplanar reconstructed CT image using image analysis software (Mimics research 21.0, Materialise, Belgium).

Table 1.

Reference points and planes

Landmarks (abbreviation) Description
Points
 Orbitale (Or) The lowest point on the lower margin of the bony orbit (OrR, right side; OrL, left side)
 Porion (Po) The highest point of the skeletal external auditory meatus (PoR, right side; PoL, left side)
 Basion (Ba) Midpoint of the anterior margin of the foramen magnum on the occipital bone
 Crista galli (Cg) The most superior point of crista galli located in the ethmoid bone
 Mesiobuccal cusp (MBC) Mesiobuccal cusp of maxillary first molar (MBCR: right; MBCL; left)
Mandibular foramen (ManF) The center point of the opening of the inferior alveolar nerve canal
 Mental foramen (MF) The center of mental foramen (MFR, right side; MFL, left side)
 Lower incisor (L1) The midpoint of the incisal edge of the mandibular central incisors
 IANant The most anterior point of the anterior loop of the inferior alveolar nerve
 IANinf The most inferior point of the anterior loop of the inferior alveolar nerve
Planes
 Mid-axial plane (MAP) A plane passing through OrR, OrL and PoL
 Mid-sagittal plane (MSP) A plane passing through Cg, Ba and normal to MAP
 Coronal plane (COP) A plane passing through Ba, and normal to MAP and MSP
Occlusal plane (OP) A plane passing through the bilateral mesiobuccal cusp of maxillary first molar and the L1
 Mandibular sagittal plane (MnSP) A plane passing through ManF, MF and normal to OP
 Horizontal reference plane (HRP) A plane passing through MF and parallel to OP
 Vertical reference plane (VRP) A plane passing through MF and normal to OP and MnSP

Reference points

Porion (Po), orbitale (Or), pogonion (Pog), mental foramen (MF), mandibular foramen (ManF), mesiobuccal cusp of maxillary first molar (MBC), midpoint of the incisal edge of the mandibular central incisors (L1), basion (Ba), and crista galli (Cg) were set as the reference points. The most anterior and the most inferior points of ALIAN were set as IANant and IANinf, respectively.

Reference planes

The mid-axial plane, mid-sagittal plane, and coronal plane were also determined. “Midaxial plane” was defined as the plane passing through bilateral Or (OrR, OrL) and left Po (PoL). “Midsagittal plane” was defined as the plane perpendicular to the midaxial plane with passing through Ba and Cg. A plane perpendicular to the midaxial plane and midsagittal plane and bypassing Ba was defined as “Coronal plane” (Fig. 1) Occlusal plane was defined as the plane passing through the bilateral mesiobuccal cusp of maxillary first molar and the L1.

Fig. 1.

Fig. 1

Reference points and plane for diagnosis of facial asymmetry. Facial asymmetry was defined when distance from Pog to midsagittal plane (Pog deviation) was over 3.5 mm. OrR, Orbitale right; OrL, Orbitale left; PoL, Porion left; Cg, Crista galli; Ba, Basion, Pog, Pogonion

To evaluate the anterior and inferior distance of the anterior loop of IAN, vertical and horizontal reference planes were set on mandible. First, a plane passing through ManF, MF and perpendicular to occlusal plane was defined as the mandibular sagittal plane. The vertical reference plane (VRP) was defined as a plane passing through MF and perpendicular to occlusal plane and mandibular sagittal plane. The horizontal reference plane (HRP) was defined as a plane passing through MF and parallel to occlusal plane (Fig. 2).

Fig. 2.

Fig. 2

Reference planes for distance measurement of the anterior loop of inferior alveolar nerve (ALIAN) (illustrated image). Occlusal plane was defined as a plane passing through L1 and the bilateral mesiobuccal cusp of the maxillary first molar. A plane passing through ManF, MF and perpendicular to occlusal plane was defined as the mandibular sagittal plane. The vertical reference plane (VRP) was defined as a plane passing through MF and perpendicular to occlusal plane and MnSP. The horizontal reference plane (HRP) was defined as a plane passing through MF and parallel to occlusal plane. MBC, Mesiobuccal cusp of maxillary first molar; ManF, Center of the opening of the inferior alveolar nerve canal; MF, Center of the mental foramen; HRP, Horizontal reference plane; VRP, Vertical reference plane

Measurements using a three-dimensional analysis program were performed twice over at least 1 week by an experienced oral and maxillofacial surgeon. This examiner was blinded to the subjects’ groups.

Definition of mandibular asymmetry

The distance from Pog to the midsagittal plane (Pog deviation) was measured. (Fig. 1) All patients were divided into two groups depending on Pog deviation as “Asymmetry” and “Symmetry” groups. Asymmetry was classified based on 3.0 mm of Pog deviation [14]. To increase the reliability of the study results, Pog deviation between 2.5 and 3.5 mm were excluded. Finally, patients were classified as “Asymmetry” group (Asy) when Pog deviation was greater than 3.5 mm. “Symmetry” group (Sym) was defined when Pog deviation was less than 2.5 mm.

Analysis of the anterior loop of IAN

Four outcome variables were defined for analysis of the ALIAN.

  1. dAnt: The distance from IANant to VRP (Fig. 3)

  2. dInf: The distance from IANinf to HRP (Fig. 3)

  3. dAnt_MF: The distance from IANant to MF

  4. dInf_MF: The distance from IANinf to MF

Fig. 3.

Fig. 3

Measurement of dAnt and dInf (illustrated image). dAnt refers to the distance from the most anterior point of the ALIAN (IANant) to the vertical reference plane (VRP). dInf refers to the distance from the most inferior point of ALIAN (IANinf) to the horizontal reference plane (HRP)

dAnt_MF and dInf_MF, were calculated using the Elucidean formula. For example, dAnt_MF were calculated as follows;

  1. The distance from IANant and MF to midaxial plane, coronal plane, and midsagittal plane were measured. (dMAP_Ant, dMAP_MF, dCOP_Ant, dCOP_MF, dMSP_Ant, dMSP_MF).

  2. Then, the difference was calculated in each plane. (e.g.dMAP_Ant– dMAP_MF).

  3. The sum of the squares of each length was calculated, and the value of the square root of the positive is obtained as shown in the following equation.
    dAntMF=(dMAP_Ant-dMAP_MF)2+(dCOP_Ant-dCOP_MF)2+(dMSP_Ant-dMSP_MF)2
    dInf_MF was also calculated in the same way. Each value was measured and calculated on both right and left side. In the Asy group, they were re-classified as the deviated and non-deviated side.

Measurements of mandibular body and symphysis length [15]

Two outcome variables were defined for analysis the length of mandibular body and symphysis. They were measured automatically by image analysis software.

  1. Mandibular body length: The distance from ManF to MF, which indicates the length of mandibular body

  2. Symphysis length: The distance from MF to Pog, which indicates the length of symphysis

Each value was measured on both the right and left side. In the Asy group, they were re-classified as the deviated and non-deviated side.

Statistical analysis

Age and sex were analyzed with Mann–Whitney test and chi-square test between the two groups. Intraclass correlation coefficient between two measurements was evaluated. Six outcome variables (dAnt, dInf, dAnt_MF, dInf_MF, mandibular body length and symphysis length) were analyzed by paired t-test in both groups. The analysis was performed using the average values of two measurements. The relationships between each distance measurements (dAnt, dInf, dAnt_MF, dInf_MF) and mandibular unit (mandibular body length and symphysis length) were analyzed by Pearson’s correlation analysis. The relationships between the difference between the non-deviated side and deviated side (i.e. non-deviated side–deviated side or left–right side) and degree of asymmetry in each variables were also analyzed by Pearson’s correlation analysis. If the normality test was not satisfied, the analysis was performed using the nonparametric test methods such as Wilcoxon signed-rank test and Spearman's rank correlation coefficient analysis. In the Asy group, the deviated and non-deviated sides were compared. In the Sym group, the right and left sides were compared. Statistical analysis was performed using SPSS version 23.0 (IBM Corp, Armonk, NY). A p-value of less than 0.05 was considered statistically significant.

Results

Eighty-one subjects were initially identified, and 24 were excluded as they did not meet the inclusion criteria. Of the 57 subjects meeting the inclusion criteria, 33 were classified as “Asy group” and 24 were classified as “Sym group”. There were 14 male and 19 female patients (mean age: 22.64 ± 5.33 years old) in Asy group. In Sym group, 15 male and 9 female patients (mean age: 22.75 ± 3.97 years old). There was no significant difference in age (p = 0.333) and sex (p = 0.134) between the two groups. (Table 2) The intraclass correlation coefficient ranged from 0.705 to 0.976, which was evaluated as "excellent" in most variables and "good" in some variables.

Table 2.

Clinical characteristics of the patients

Asy group (n = 33) Sym group (n = 24) p-value
Age 22.64 ± 5.33 22.75 ± 3.97 0.333
Sex (n, %) 0.134
 Male 14 (42.4) 15 (62.5)
 Female 19 (57.6) 9 (37.5)

Mann–Whitney test

Comparisons of distance of ALIAN (dAnt, dAnt_MF, dInf, and dInf_MF), and mandibular unit (mandibular body length and symphysis length) on deviated and non-deviated side (left and right side) in both groups (Table 3)

Table 3.

Comparison of length of ALIAN, length of mandibular subunits on Asymmetry and Symmetry groups

Asy group (n = 33) Sym group (n = 24)
Mean ± SD (Min, Max) p-value Mean ± SD (Min, Max) p-value
dAnt Dev† 1.79 ± 1.04 (0.57, 5.31)  < 0.001* Left 1.97 ± 1.00 (0.12, 4.98) 0.746
Ndev† 3.05 ± 1.04 (1.04, 5.43) Right 1.94 ± 0.89 (0.54, 4.56)
dAnt_MF Dev 4.24 ± 1.42 (2.18, 8.35)  < 0.001* Left† 4.30 ± 1.20 (2.26, 8.01) 0.324
Ndev 5.32 ± 1.60 (2.69, 9.50) Right† 4.27 ± 1.28 (1.88, 7.75)
dInf Dev 5.09 ± 1.48 (2.46, 8.08) 0.060 Left 5.44 ± 1.12 (3.06, 8.07) 0.501
Ndev 5.42 ± 1.69 (2.54, 8.72) Right 5.29 ± 1.14 (3.42, 8.01)
dInf_MF Dev 7.06 ± 1.70 (4.37, 10.96) 0.001* Left 7.27 ± 1.21 (5.46, 9.71) 0.392
Ndev 7.95 ± 2.03 (5.19, 12.55) Right 7.12 ± 1.03 (4.94, 9.30)
Mandibular body length Dev 62.47 ± 4.51 (55.38, 73.16)  < 0.001* Left 66.24 ± 5.45 (55.21, 75.51) 0.368
NDev 65.61 ± 5.25 (55.44, 77.64) Right 66.74 ± 5.53 (55.25, 76.99)
Symphysis length Dev 30.96 ± 2.34 (25.82, 34.88) 0.623 Left 30.63 ± 2.30 (26.63, 35.03) 0.158
NDev 30.82 ± 2.22 (26.67, 35.00) Right 31.17 ± 2.26 (26.63, 35.50)

ALIAN, anterior loop of inferior alveolar nerve; Asy, Asymmetry; Sym, Symmetry; dAnt, distance from IANant to VRP; dAnt_MF, distance from IANant to MF; dInf, distance from IANinf to HRP; dInf_MF, distance from IANinf to MF; Asy, Asymmetry; Sym, Symmetry; Dev, deviated side; Ndev, non-deviated side

Wilcoxon signed-rank test

*Indicates p < 0.05

In the Asy group, the distance between IANant and VRP (dAnt) on the deviated (3.05 ± 1.04 mm) and the non-deviated (1.79 ± 1.04 mm) side showed a statistically significant difference (p < 0.001). dAnt_MF on the deviated side was 4.24 ± 1.53 mm, and on the non-deviated side was 5.32 ± 1.60 mm, which also showed a statistically significant difference (p < 0.001). dInf was longer on the non-deviated side than on the deviated side, but there was no statistically significant difference between the deviated and non-deviated sides (p = 0.060). In the Sym group, there were no statistically significant differences in the lengths of the left and right sides.

The mandibular body length showed a significant difference between the deviated side (62.47 ± 4.51 mm) and the non-deviated side (65.61 ± 5.25 mm) in the Asy group (p < 0.001). However, the symphysis area did not show any difference (p = 0.623). In the Sym group, mandibular body length and symphysis length also showed no significant differences between the right and left sides (p = 0.420 and p = 0.216, respectively).

Relationship between distance of ALIAN and degree of asymmetry

In the Asy group, difference between non-deviated and deviated side (i.e. non-deviated -deviated side) had positive correlations with degree of asymmetry in dAnt (ρ = 0.665, p < 0.001), dAnt_MF (r = 0.396, p = 0.023), dInf_MF (r = 0.429, p = 0.013) with significant difference (Fig. 4). In the Sym group, there was no significant correlation between degree of asymmetry and distance of ALIAN (Fig. 5).

Fig. 4.

Fig. 4

Relationship between degree of asymmetry and difference of non-deviated side and deviated side in Asy group. Ndev, non-deviated side; Dev, deviated side, dAnt, the distance from the most anterior point of the ALIAN (IANant) to vertical reference plane; dInf, the distance from the most inferior point of ALIAN (IANinf) to horizontal reference plane; dAnt_MF, The distance from IANant to the mental foramen; dInf_MF, The distance from IANinf to the mental foramen; r, Pearson’s correlation coefficiency; ρ, Spearman’s rho. *p < 0.05. Spearman’s rank correlation coefficient analysis

Fig. 5.

Fig. 5

Relationship between degree of asymmetry and difference of left and right side in Sym group. dAnt, the distance from the most anterior point of the ALIAN (IANant) to vertical reference plane; dInf, the distance from the most inferior point of ALIAN (IANinf) to horizontal reference plane; dAnt_MF, The distance from IANant to the mental foramen; dInf_MF, The distance from IANinf to the mental foramen; r, Pearson’s correlation coefficiency; ρ, Spearman’s rho. Spearman’s rank correlation coefficient analysis

Relationship between distance of ALIAN and mandibular unit in both groups (Table 4)

Table 4.

Correlation coefficient analysis between ALIAN and mandibular subunits

Asy group Sym group
Mandibular body length Symphysis length Mandibular body length Symphysis length
Co p Co p Co p Co p
dAnt 0.348* 0.004 0.242 0.050 dAnt 0.321* 0.026 0.177 0.229
dAnt_MF† 0.387* < 0.001 0.319* 0.009 dAnt_MF 0.139 0.346 0.089 0.549
dInf 0.337* 0.006 0.182 0.144 dInf − 0.079 0.594 0.062 0.677
dInf_MF 0.413* 0.001 0.261* 0.035 dInf_MF − 0.041 0.780 0.072 0.626

ALIAN, anterior loop of inferior alveolar nerve; Asy, Asymmetry; Sym, Symmetry; dAnt, distance from IANant to VRP; dAnt_MF, distance from IANant to MF; dInf, distance from IANinf to HRP; dInf_MF, distance from IANinf to MF

*Indicates p < 0.05

Spearman’s rank correlation coefficient analysis

In the Asy group, mandibular body length had a positive correlation with dAnt, dAnt_MF, dInf, and dInf_MF, with statistical significance. dAnt_MF and dInf_MF also showed a positive correlation with symphysis length with statistical significance. In the Sym group, there were no significant correlations in all parameters except dAnt and mandibular body length.

Discussion

The purpose of this study was to investigate (1) the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry and (2) the relationship with the mandibular subunit. Although the length of the ALIAN on the left and right sides can be compared easily on panoramic radiographs, CT images yield more reliable and accurate measurements, and also show a higher prevalence of the anterior loop than in panoramic radiographs [16, 17]. Thus, in this study, we analyzed CTs taken before orthognathic surgery.

Six variables were evaluated: (1) the distance from IANant to the vertical reference plane (VRP), (2) the distance from IANinf to horizontal reference plane (HRP), (3) the distance from IANant and to MF, (4) the distance from IANinf to MF, (5) the distance from ManF to MF (length of mandibular body), and (6) the distance from MF to Pog (length of symphysis). All items were measured on the left and right sides. The Asy group was reclassified as the deviated side and the non-deviated side to evaluate according to the asymmetry. To minimize errors, measurements were taken twice by one observer. The intraclass correlation coefficient for the repeated measurements ranged from 0.705 to 0.976, which was evaluated as "excellent" in most variables and "good" in some variables [18]. Thus, the data was considered to be reliable.

According to the results of this study, the values in dAnt and dAnt_MF between the deviated and the non-deviated sides showed significant differences in Asy group (p < 0.001). There was a significant difference on the deviated and non-deviated sides in dInf_MF in Asy group (p = 0.001). This overall shows that the ALIAN deviates less from the mental foramen on the deviated side in asymmetric mandibles. In the Sym group, however, both dAnt and dAnt_MF were not different between the left and right sides.

To analyze whether the differences in the ALIAN between the deviated and non-deviated sides in the Asy group correlated with different mandibular subunits, we measured the length of mandibular body and symphysis based on previous studies [15]. In the Asy group, the length of the mandibular body showed significant differences (p < 0.001), whereas the length of symphysis area did not (p = 0.623). In the Sym group, both mandibular body length and symphysis length on the left and right sides did not show any difference statistically. These results are consistent with those of You et al. and Park et al., who reported that in facial asymmetry there was no difference in the length of the symphysis but the length of mandibular body [15, 19, 20].

In correlation analysis, dAnt, dInf, dAnt_MF, and dInf_MF showed a positive relationship with mandibular body length with statistical significance in the Asy group. In the Sym group, however, there was no significant positive correlation in all variables except dAnt and mandibular body length as shown in Table 4. Therefore, it seems that the anterior and inferior distances of ALIAN are related to the growth of mandible, especially the growth of mandibular body.

Knowledge of the configuration and dimensions of the ALIAN is important in surgical procedures such as dental implant placement and bone harvesting in the anterior mandible, and genioplasty [10, 21]. The results of this study show differences in the configuration and dimensions of the ALIAN in symmetrical and asymmetrical mandibles, highlighting the need for potentially using different safety margins for certain osteotomy or ostectomy procedures for each side in asymmetric mandibles. Therefore, recognition of the difference of the ALIAN in asymmetric patients is important, especially in a bilateral procedure. While clinicians assess individual anatomy of the ALIAN when three-dimensional imaging is available, knowledge of average configurations and mean dimensions serves as a valuable reference when fine cortications of the mandibular canal are not readily visible, or when three-dimensional imaging is not available. Data from this study could also be of particular use in nerve lateralization for procedures such as inferior border ostectomy in hemimandibular hyperplasia, which require greater three-dimensional knowledge of the anatomy of the ALIAN.

This study has some limitations in that all measurements were made by one observer. Although intra-observer reliability was assessed and found to be satisfactory, inter-observer reliability was not accounted for. In addition, while reference planes are critical to standardize the imaging analysis and measurements, they are somewhat difficult to reproduce completely in actual clinical situations. However, this limitation is not unique to this study, and applies to any clinical situation in which imaging or reference ranges are relied on to determine anatomy without use of adjuncts such as surgical guides or navigation.

Conclusion

Within the limitation of this study, there is a tendency of difference in ALIAN between the deviated and non-deviated sides in asymmetric patients. Therefore, this should be considered during surgery in the anterior mandible in patients with mandibular asymmetry.

Acknowledgements

We would like to thank Ms. Hye Sun Lee (Ph.D., Biostatistician) and Ms. Sinae Kim (M.S. Biostatistician) from the Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul, Korea, for their help with statistical analysis. We also appreciate Mr. Young Jae Kim and 3Dgraphics Co. for figure illustration.

This study was supported by a faculty research grant from the Yonsei University College of Dentistry (6-2015-0112). There is no conflict of interest to be declared.

Abbreviations

ALIAN

Anterior loop of the inferior alveolar nerve

MF

Mental foramen

Po

Porion

Or

Orbitale

Pog

Pogonion

ManF

Mandibular foramen

MBC

Mesiobuccal cusp of maxillary first molar

L1

Midpoint of the incisal edge of the mandibular central incisors

Ba

Basion

Cg

Crista galli

IANant

The most anterior point of the ALIAN

IANinf

The most inferior point of the ALIAN

dAnt

The distance from IANant to vertical reference plane

dInf

The distance from IANinf to horizontal reference plane

dAnt_MF

The distance from IANant to the mental foramen

dInf_MF

The distance from IANinf to the mental foramen

Author's contributions

J.-Y. Kim wrote the manuscript as first author and analyze acquisition. M.D. Han interpreted date and was a major contributor in writing the manuscript. K.G. Jeon contributed to analyze data and interpretation. J.-K. Huh contributed to design of the work and acquisition of the data. K.-H. Park drafted the work and revised final manuscript as corresponding author. All authors read and approved the final manuscript.

Funding

This study was supported by a faculty research grant from the Yonsei University College of Dentistry (6–2015-0112).

Availability of data and materials

All data generated or analysed during this study are included in this published article.

Ethics approval and consent to participate

This study was approved by the institutional review board of Gangnam Severance Hospital (approval No. #3-2019-0236) and complied with the tenets of the Declaration of Helsinki. Written or verbal informed consent was waived by the IRB of Gangnam Severance Hospital, as this study had a retrospective design and all data were analyzed anonymously.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Jae-Young Kim, Email: kjy810927@yuhs.ac.

Michael D. Han, Email: hanmd@uic.edu

Kug Jin Jeon, Email: dentjeon@yuhs.ac.

Jong-Ki Huh, Email: omshuh@yuhs.ac.

Kwang-Ho Park, Email: omspark@yuhs.ac.

References

  • 1.Moghddam MR, Davoudmanesh Z, Azizi N, Rakhshan V, Shariati M. Prevalence and length of the anterior loop of the inferior alveolar nerve in Iranians. J Oral Implantol. 2017;43(5):333–336. doi: 10.1563/aaid-joi-D-16-00212. [DOI] [PubMed] [Google Scholar]
  • 2.Apostolakis D, Brown JE. The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging. Clin Oral Implants Res. 2012;23(9):1022–1030. doi: 10.1111/j.1600-0501.2011.02261.x. [DOI] [PubMed] [Google Scholar]
  • 3.Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H, Sato I, Kawai T, Yosue T. Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg. 2009;67(4):744–750. doi: 10.1016/j.joms.2008.05.352. [DOI] [PubMed] [Google Scholar]
  • 4.Wong SK, Patil PG. Measuring anterior loop length of the inferior alveolar nerve to estimate safe zone in implant planning: A CBCT study in a Malaysian population. J Prosthetic Dentistry. 2018;120(2):210–213. doi: 10.1016/j.prosdent.2017.10.019. [DOI] [PubMed] [Google Scholar]
  • 5.Sati S, Havlik RJ. An evidence-based approach to genioplasty. Plast Reconstr Surg. 2011;127(2):898–904. doi: 10.1097/PRS.0b013e31820461c5. [DOI] [PubMed] [Google Scholar]
  • 6.Hoenig JF. Sliding osteotomy genioplasty for facial aesthetic balance: 10 years of experience. Aesthetic Plast Surg. 2007;31(4):384–391. doi: 10.1007/s00266-006-0177-6. [DOI] [PubMed] [Google Scholar]
  • 7.Jones BM, Vesely MJ. Osseous genioplasty in facial aesthetic surgery—a personal perspective reviewing 54 patients. J Plast Reconstr Aesthet Surg. 2006;59(11):1177–1187. doi: 10.1016/j.bjps.2006.04.011. [DOI] [PubMed] [Google Scholar]
  • 8.Hwang K, Lee WJ, Song YB, Chung IH. Vulnerability of the inferior alveolar nerve and mental nerve during genioplasty: an anatomic study. J Craniofac Surg. 2005;16(1):10–14. doi: 10.1097/00001665-200501000-00004. [DOI] [PubMed] [Google Scholar]
  • 9.Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ. Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implants Res. 2003;14(4):464–471. doi: 10.1034/j.1600-0501.2003.00869.x. [DOI] [PubMed] [Google Scholar]
  • 10.Filo K, Schneider T, Locher MC, Kruse AL, Lubbers HT. The inferior alveolar nerve's loop at the mental foramen and its implications for surgery. J Am Dental Assoc. 2014;145(3):260–269. doi: 10.14219/jada.2013.34. [DOI] [PubMed] [Google Scholar]
  • 11.Tai K, Park JH, Ikeda K, Nishiyama A, Sato Y. Severe facial asymmetry and unilateral lingual crossbite treated with orthodontics and 2-jaw surgery: 5-year follow-up. Am J Orthodontics Dentofac Orthop. 2012;142(4):509–523. doi: 10.1016/j.ajodo.2011.01.026. [DOI] [PubMed] [Google Scholar]
  • 12.Jae-Yeol L, Yong-Il K, Dae-Seok H, Yong-Deok K, Sang-Hun S, Uk-Kyu K, In-Kyo C. Cross-sectional study of the mandibular body in patients with facial asymmetry. J Korean Assoc Oral Maxillofac Surg. 2011;37(2):109–113. doi: 10.5125/jkaoms.2011.37.2.109. [DOI] [Google Scholar]
  • 13.Yoon S, Kim JY, Jeong CH, Park J, Huh JK, Park KH. Three-dimensional analysis of the anterior loop of the inferior alveolar nerve in relation to the growth pattern of the mandibular functional subunit. Maxillofac Plast Reconstr Surg. 2018;40(1):30. doi: 10.1186/s40902-018-0170-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Chebib FS, Chamma AM. Indices of craniofacial asymmetry. Angle Orthod. 1981;51(3):214–226. doi: 10.1043/0003-3219(1981)051<0214:IOCA>2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 15.You KH, Lee KJ, Lee SH, Baik HS. Three-dimensional computed tomography analysis of mandibular morphology in patients with facial asymmetry and mandibular prognathism. Am J Orthodontics Dentofac Orthop. 2010; 138(5):540 e541–548; discussion 540–541. [DOI] [PubMed]
  • 16.Kaya Y, Sencimen M, Sahin S, Okcu KM, Dogan N, Bahcecitapar M. Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography. Int J Oral Maxillofac Implants. 2008;23(5):919–925. [PubMed] [Google Scholar]
  • 17.Vujanovic-Eskenazi A, Valero-James JM, Sanchez-Garces MA, Gay-Escoda C. A retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and cone beam computerized tomography. Med Oral Patol Oral Cir Bucal. 2015;20(2):e239–245. doi: 10.4317/medoral.20026. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Cicchetti DV, Nelson LD. Re-examining threats to the reliability and validity of putative brain–behavior relationships: new guidelines for assessing the effect of patients lost to follow-up. J Clin Exp Neuropsychol. 1994;16(3):339–343. doi: 10.1080/01688639408402644. [DOI] [PubMed] [Google Scholar]
  • 19.You KH, Kim KH, Lee KJ, Baik HS. Three-dimensional computed tomography analysis of mandibular morphology in patients with facial asymmetry and mandibular retrognathism. Am J Orthodontics Dentofac Orthop. 2018;153(5):685–691. doi: 10.1016/j.ajodo.2017.08.024. [DOI] [PubMed] [Google Scholar]
  • 20.Park KR, Park HS, Piao Z, Kim MK, Yu HS, Seo JK, Lee SH. Three-dimensional vector analysis of mandibular structural asymmetry. J Cranio-maxillo-facial Surg. 2013;41(4):338–344. doi: 10.1016/j.jcms.2012.11.031. [DOI] [PubMed] [Google Scholar]
  • 21.Todorovic VS, Postma TC, van Zyl AW. Assessment of the anterior loop of the inferior alveolar nerve using reformatted computed tomography: a retrospective study. Br J Oral Maxillofac Surg. 2018;56(3):186–191. doi: 10.1016/j.bjoms.2018.01.007. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

All data generated or analysed during this study are included in this published article.


Articles from BMC Oral Health are provided here courtesy of BMC

RESOURCES