Skip to main content
Revista Brasileira de Ortopedia logoLink to Revista Brasileira de Ortopedia
. 2020 Jul 8;56(1):53–60. doi: 10.1055/s-0040-1709989

Comparative Study of the Function and Quality of Life of Patients Submitted to Total Knee Arthroplasty with Fixed and Mobile Tibial Platforms

Daiane Cavenaghi Nacca 1, Joicemar Tarouco Amaro 1, Mateus Kenji Christo Miyahira 2,, João Victor Novaretti 1, Diego Costa Astur 1, Moisés Cohen 1
PMCID: PMC7895627  PMID: 33627900

Abstract

Objective  To compare the function and quality of life of patients undergoing total knee arthroplasty (TKA) with fixed tibial platform and mobile tibial platform.

Methods  We evaluated 240 patients with knee osteoarthritis, randomized into two groups - Group A consisted of 120 patients who underwent TKA with fixed tibial platform, and the B group, consisting of 120 patients who underwent mobile platform arthroplasty. Patients were accessed according to the function and quality of life by the Western Ontario and McMaster Universities Arthritis Index (WOMAC) and the Short Form Health Survey (SF-36), and pain scores by visual analog scale (VAS) of pain, preoperatively and at 6 months, 1 year, 2 years, 4 years and 8 years of surgery.

Results  Regarding the various domains of the SF-36, we observed that the average behavior of functional capacity scores, physical aspects, pain and emotional aspects in the patient groups were statistically different during follow-up. The other domains of quality of life showed no mean differences. Regarding the pain assessed by VAS and WOMAC pain scores, we can see that it showed a mean change in follow-up in both patient groups. However, at 2 years of follow-up, they were statistically worse in group A, equaling group B in the other moments.

Conclusion  After 2 years of follow-up, we observed that pain scores and VAS were lower in the fixed platform group. However, these differences did not remain in the mid-term, suggesting that the mobile tibial platform arthroplasty has a short-term advantage, and may help in the rehabilitation process.

Keywords: arthroplasty, replacement, knee; quality of life; osteoarthrosis

Introduction

In the last decades, with the ageing of the general population and the changes in the musculoskeletal system resulting from this process, osteoarthritis has become an important health problem. 1 2 3 The symptoms of this degenerative joint cartilage disease lead to functional disability and loss of quality of life for the elderly. 4 5 6 7 8 9 These have been elements of evaluation of treatments, including total knee arthroplasty (TKA). 10 11

The methods for evaluating the results of TKA are mortality rates, morbidity, complications, and durability. However, with the rapid growth of improvements in procedures, these rates no longer reflect the real benefit in the quality of life of the individual. 12 13 14 Thus, evaluations with generic or specific questionnaires regarding treatment have provided valuable information. Among them, the Western Ontario and McMaster Universities Arthritis Index (WOMAC) for TKA, and the Short Form Health Survey (SF-36) to assess quality of life, stand out. 10 15 These questionnaires have shown the good results of TKA in improving the function and quality of life of elderly patients.

Total knee arthroplasty can be divided according to the tibial component into two types: TKA with fixed platform and with mobile platform. According to Wylde and Potter, 16 the standard TKA - with fixed platform - can lead to an excessive load in the posterior region of the tibial component, increasing polyethylene wear, leading to a higher risk of failure, and the need for revision. Thus, TKA with a mobile platform, as it allows greater rotational mobility and better congruence of the polyethylene component, has the theoretical advantage of self-aligning, reducing the incidence of anterior knee pain, producing better function.

In view of this, the theoretical advantages of TKA with a mobile platform must be confirmed clinically, since until now, there is no consensus regarding the best results, and previous studies were considered of low quality. 17

The objective of the present study is to compare the function and quality of life of patients who underwent TKA with fixed and mobile platforms.

Methods

All procedures were approved by the research ethics committee of our university.

This is a randomized, double-blind clinical trial, conducted from January 2004 to January 2007. Inclusion criteria were: 1– age between 55 and 70 years old, 2–clinical signs and symptoms compatible with knee osteoarthritis, 3–radiographic signs of three-compartment osteoarthritis grades III, IV and V according to the Ahlbäck classification modified by Keyes and Goodfellow, 4–absence of associated diseases affecting the lower limbs, 5–absence of neurological disorder, 6–absence of nerve injuries or previous fractures in the lower limbs. The non inclusion criteria were: 1–infection, 2–flexion deformity > 10°, 3–angular deviations in varus and valgus > 25°, 4–focal tumor defect, 5–physical conditions that would eliminate adequate implant support, 6–coexisting life-threatening disease in the year following the procedure. Patients who said that they were unable or unsure of returning for follow-up were excluded from the study.

After a complete clinical and radiological evaluation, patients with indication for TKA who met the criteria were invited to participate in the study. Those who confirmed their participation signed the free and informed consent form. The randomization method used was block exchange, with the aim of maintaining a similar distribution of the number of patients in each studied group. Eight patient blocks were created, with different combinations. Sealed, opaque envelopes numbered from 1 to 240 contained the group to which each patient belonged. The first group (group A), submitted to TKA with fixed tibial platform (Depuy Synthes, Warsaw, IN, USA), and the second group (group B), submitted to TKA with a mobile tibial platform (LCS, Depuy Synthes, Warsaw, IN, USA).

All of the patients were assessed with questionnaires in the preoperative and postoperative periods at 6, 24, 48 and 96 months regarding function (WOMAC), quality of life (SF-36) and subjective pain perception (visual analogue scale [VAS] for pain).

Sample Size

To accept an alpha risk of 0.05 and aβ risk of 0.20, 98 patients were needed for each group to detect a ≥ 08 points difference between the average of pre- and postoperative scores for the dimensions of pain and function using the WOMAC questionnaire, deemed a clinically important difference. 18 A common standard deviation (SD) of 20 was assumed. The sample was overestimated by 20% to allow for possible losses, so that each group should contain 120 patients.

Surgical Technique

All prostheses were implanted by the same surgeon. In all patients, spinal anesthetic block was performed. For 48 hours, prophylactic antibiotic therapy with sodium cefazolin was used. Pneumatic tourniquet was used routinely. The access route was the anterior one with medial parapatellar arthrotomy. The patella was everted and replaced in all cases. Both prostheses had a similar femoral component, and all were later stabilized. Both cruciate ligaments were extracted. Horizontal tibial bone cutting was performed first, using an extramedullary guide for the tibia and intramedullary for the femur. All of the components were cemented. A suction drain was used for 24 hours as a routine. For thromboembolic prophylaxis, for 14 days, patients received low molecular weight heparin.

Rehabilitation

Rapid mobilization was recommended, in which, on the first postoperative day, metabolic ankle exercises and isometric exercises for the quadriceps were performed. On the second postoperative day, after the suction drain was removed, gait training with a walker and weight unloading in both limbs began. Gait training was performed according to the tolerance of each patient (pain and clinical conditions). All of them underwent one-hour sessions of continuous passive movement (CPM), twice a day (morning and afternoon), and the angle of movement varied according to the pain tolerance by each patient. Hospital discharge was given on average 5 days after the surgery, when the patient reached close to 90° of knee flexion and was able to walk independently with crutches or a walker. The outpatient physiotherapy sessions started 1 week after hospital discharge. The outpatient rehabilitation program lasted an average of 2 months, being similar for both groups.

Clinical Evaluation

The function was evaluated using the WOMAC, being composed of three domains: function, pain and stiffness. The sum of the points of each domain forms the result, varying from 0 to 68. To assess quality of life, the SF-36 was used, ranging from 0 to 100, presenting 36 response items, involving 8 concepts: functional capacity, physical aspect, pain, general health, vitality, social aspects, emotional aspects and mental health. The EVA was also applied, varying from 0 to 10.

Statistical Analysis

There was an association between the types of prosthesis and the characteristics using chi-squared tests. 19 The quantitative characteristics of the patients were described according to the types of prosthesis using summary measures (mean, SD, median and quartiles, P25 and P75) and compared between the groups using the analysis of t-Studenttests. 19 The scores of the evaluated scales were described according to the types of prosthesis at each evaluation moment and compared between the types of prosthesis and moments using generalized estimation equation analyses with normal marginal distribution and logarithmic link function, due to the asymmetric distribution of scores, assuming a first-order autoregressive correlation between the moments of assessment. 20 The analyses were followed by multiple comparisons of Bonferroni 21 to compare groups and times, when differences in scores were significant. The analyses were performed with the data evaluated in the patients, even considering losses during the follow-up. The results were illustrated with graphs of average profiles, with the respective standard errors, and the tests were performed with a significance level of 5%.

Results

Patients were recruited consecutively from November 2011 until December 2012. In total, 1,268 patients were evaluated and 1,028 were excluded, resulting in a final sample of 240 patients. Patients were randomized into 2 groups: 120 in the TKA with fixed platform and 120 in the TKA with mobile platform. From the fixed platform group, five patients died, and six did not adhere. From the mobile platform group, six died, four did not adhere, one had a cerebral vascular accident (CVA) and one had a rupture of the patellar ligament. All deaths occurred after >2 years of follow-up ( Figure 1 ).

Fig. 1.

Fig. 1

Flowchart of Phases.

Of the 240 randomized patients, 6 from the fixed platform group and 5 from the mobile platform group experienced complications. In the fixed platform group, we had three cases of infection, two with embolism and one with deep venous thrombosis. In the mobile platform group, we had two cases of infection, one with deep venous thrombosis, one with CVA, and one with rupture of the patellar ligament.

The ages of the individuals in the sample were between 59 and 70 years old, with an average of 65.7 years old (SD= 3.7). A total of 81% were female, with a body mass index (BMI) of 30 (SD = 4.7). The personal characteristics evaluated did not show any association or statistically significant differences; therefore, the groups were homogeneous, as shown in Table 1 .

Table 1. Description of personal characteristics of the patients according to types of prosthesis and results of statistical tests.

Variable Prosthesis type Total ( N  = 240) p Value
Fixed ( N  = 120) Mobile ( N  = 120)
Gender, n (%)
Female 96 (80) 100 (83.3) 196 (81.7) 0.505*
Male 24 (20) 20 (16.7) 44 (18.3)
Operated side, n (%)
Right 64 (53.3) 57 (47.5) 121 (50.4) 0.366*
Left 56 (46.7) 63 (52.5) 119 (49.6)
Age (years)
mean (SD) 65.9 (3.9) 65.4 (3.4) 65.7 (3.7) 0.369
median (P25; P75) 66 (63; 70) 65 (63; 68) 65 (63; 69)
Weight (Kg)
Mean (SD) 78.4 (12.1) 80.3 (13.5) 79.4 (12.8) 0.276
median (P25; P75) 78.5 (73; 85) 78.5 (71; 87) 78.5 (72; 86)
Height (m)
mean (SD) 1.62 (0.06) 1.62 (0.14) 1.62 (0.10) 0.320
median (P25; P75) 1.63 (1.6; 1.66) 1.63 (1.57; 1.67) 1.63 (1.59; 1,67)
BMI (Kg/m2)
mean (DP) 29.7 (4.2) 30.2 (5.1) 30 (4.7) 0.426
median (P25; P75) 29.5 (27.2; 32.3) 30.1 (27.2; 33.1) 29.7 (27.2; 32,9)

Abbreviations: BMI, body mass index; SD, standard deviation.

t-Student test; * Chi-squared test.

Regarding the various domains of the SF-36 quality of life questionnaire, no difference was shown between groups regarding quality of life at the end of the follow-up. Only in some domains there is a difference between groups at certain times. An example is in the pain score in 1 and 2 years of follow-up, but they seem to equal each other in other moments.

Table 2 shows that the average behavior of the scores of functional capacity, pain and emotional aspects, were statistically different during the follow-up, in the groups of patients, according to the values highlighted in the table. The other domains of quality of life showed mean differences only during the follow-up, at different times of assessment, but with no difference between groups.

Table 2. Description of quality of life scores according to types of prosthesis and moments of evaluation and statistical results.

Variable Moment Prosthesis type p Value Prosthesis type p Value Moment p Value Interaction
Fixed Mobile
Mean SD N Mean SD N
Functional capacity Preoperative 20.22 18.10 120 17.17 14.79 120 0.219 <0.001 0.019
6 months 57.54 19.47 120 62.79 19.39 120
1 year 65.46 15.38 120 74.42 17.32 120
2 years 68.37 16.76 120 73.88 16.71 120
4 years 61.63 15.46 120 63.88 15.14 120
8 years 51.46 16.72 120 55.46 16.09 120
Physical aspects Preoperative 13.48 26.58 120 17.23 25.76 120 0.910 <0.001 0.536
6 months 71.68 28.24 120 67.86 37.68 120
1 year 77.08 24.38 120 73.96 31.49 120
2 years 88.27 65.30 120 82.75 29.13 120
4 years 84.77 23.00 120 75.43 35.65 120
8 years 78.93 25.52 120 78.34 28.06 120
Pain Preoperative 41.89 26.12 120 35.34 22.69 120 0.053 <0.001 0.004
6 months 80.19 26.03 120 79.39 23.79 120
1 year 75.41 30.97 120 86.20 18.29 120
2 years 69.63 34.84 120 92.49 86.12 120
4 years 76.72 28.09 120 81.05 19.50 120
8 years 74.07 27.78 120 85.28 62.49 120
General Health Status Preoperative 69.58 18.19 120 71.60 16.32 120 0.512 <0.001 0.167
6 months 77.96 13.10 120 80.53 12.77 120
1 year 78.10 12.54 120 76.38 15.23 120
2 years 76.18 12.89 120 72.29 18.29 120
4 years 77.21 14.26 120 75.18 15.45 120
8 years 74.88 14.10 120 73.51 14.69 120
Vitality Preoperative 68.03 18.79 120 68.45 19.16 120 0.366 <0.001 0.779
6 months 78.64 14.60 120 78.14 15.10 120
1 year 79.49 13.16 120 77.23 16.89 120
2 years 78.36 14.18 120 75.43 17.09 120
4 years 78.85 14.14 120 77.98 15.59 120
8 years 79.56 16.12 120 77.98 15.93 120
Social Aspects Preoperative 45.90 26.75 120 50.80 27.66 120 0.062 <0.001 0.080
6 months 81.65 23.33 120 86.17 20.40 120
1 year 84.28 23.08 120 87.68 20.49 120
2 years 85.06 21.43 120 84.22 23.49 120
4 years 83.60 22.30 120 84.38 24.01 120
8 years 78.95 25.64 120 87.13 20.68 120
Emotional Aspects Preoperative 52.68 45.09 120 40.26 45.11 120 0.771 <0.001 0.036
6 months 73.54 36.84 120 81.40 35.59 120
1 year 79.74 34.68 120 86.65 29.79 120
2 years 92.98 109.76 120 86.61 30.13 120
4 years 86.88 90.35 120 86.08 29.47 120
8 years 81.36 30.33 120 87.21 27.42 120
Mental health Preoperative 71.04 20.07 120 73.81 18.15 120 0.317 <0.001 0.484
6 months 77.27 17.25 120 76.85 16.31 120
1 year 76.87 17.04 120 77.20 13.12 120
2 years 75.05 19.15 120 75.99 14.34 120
4 years 75.09 19.65 120 78.43 14.58 120
8 years 73.58 19.55 120 75.90 16.25 120

Abbreviation: SD, standard deviation.

In Table 3 , VAS for pain and WOMAC scores showed, on average, statistically different behavior between groups during follow-up ( p < 0.001). In the WOMAC function and stiffness score, there was a statistically significant mean difference only during the follow-up, at different times of assessment, with no difference between groups ( p < 0.001).

Table 3. Visual analogue scale description of pain and functionality scores according to the types of prosthesis and moments of evaluation and statistical results.

Variable Moment Prosthesis type p Value Prosthesis type p Value Moment p Value Interaction
Fixed Mobile
Mean SD N Mean SD N
VAS for Pain Preoperative 84.69 17.04 120 85.40 17.49 120 0.016 <0.001 <0.001
6 months 26.43 22.13 120 24.70 22.43 120
1 year 25.63 15.08 120 20.53 20.85 120
2 years 28.83 19.40 120 16.57 18.97 120
4 years 14.06 17.39 120 13.04 18.07 120
8 years 13.78 16.37 120 10.56 16.59 120
WOMAC for Pain Preoperative 13.60 3.86 120 14.04 3.42 120 0.032 <0.001 <0.001
6 months 3.46 3.53 120 3.42 3.82 120
1 year 3.86 3.30 120 2.67 3.91 120
2 years 5.11 3.97 120 2.86 4.01 120
4 years 2.91 3.06 120 2.24 3.92 120
8 years 2.31 3.21 120 1.77 3.72 120
WOMAC function Preoperative 43.64 13.91 120 45.36 12.60 120 0.037 <0.001 0.001
6 months 14.11 11.78 120 10.94 9.45 120
1 year 9.62 9.81 120 8.53 7.79 120
2 years 8.83 9.81 120 7.11 7.39 120
4 years 13.12 9.81 120 10.13 7.96 120
8 years 21.37 10.90 120 18.31 8.47 120
WOMAC stiffness Preoperative 4.40 2.43 120 5.01 2.34 120 0.198 <0.001 0.203
6 months 1.38 1.66 120 1.31 1.40 120
1 year 0.98 1.49 120 0.99 1.25 120
2 years 0.88 1.49 120 0.58 1.00 120
4 years 0.94 1.43 120 0.63 1.02 120
8 years 0.93 1.49 120 0.68 1.04 120

Abbreviations: SD, standard deviation; VAS, visual analogue scale; WOMAC, Western Ontario and McMaster Universities Arthritis Index.

Discussion

The present prospective, randomized and controlled study found that, 8 years after the surgery, there were no significant differences in the clinical outcome of pain in the SF-36 and WOMAC quality of life questionnaires, as well as in the VAS scores, after knee prosthesis surgery with fixed tibial platform in relation to mobile platform implants. Recent prospective randomized studies 16 22 23 also failed to find a difference in clinical evolution, radiological analysis or survival between fixed and mobile prostheses. These same authors compared the clinical results of the two types of implants in the same patient and found no differences in pain and range of motion (ROM) scores over 5 years of follow-up. Aglietti et al, 24 in their study of patients undergoing unilateral knee arthroplasty comparing the two types of prostheses, they also did not observe significant differences with 3 years of follow-up in pain scores, although greater flexion was pointed out in knees with fixed tibial platform. It is possible that the lack of difference in clinical results after 8 years of follow-up found in the present study, between implants with fixed platform and mobile platform, was due to the characteristics of the participants, especially regarding the age group.

In addition, the generic instrument for evaluating the SF-36 quality of life of patients in this age group contributes to confirm these results, but it seems insufficient when used separately to establish conclusions from the clinical point of view. When pain is analyzed, some patients are confused, because the issue is related to “pain in the body.” All of the questions regarding pain, such as emotional aspects, disposition, and vitality, were often answered positively, but in almost all cases it was difficult to relate the response directly to the knee, as they are questions of greater scope.

The average age of the participants in the present study was 65.7 (SD = 3.7) years old, and the majority did not perform recreational or sports physical activities that required a higher degree of joint movement. According to Wylde et al, 16 the mobile tibial support prosthesis was designed to provide a greater range of joint movement and to allow participation in activities that require greater knee mobility in all planes. Therefore, it can be argued that the implantation of mobile tibial knee support did not reach its full potential in this group of patients because it is a study of an older population. A randomized clinical trial involving younger, more active patients, could reveal some functional advantage of one design over another.

An important finding of the present study that must be highlighted is the fact that, in a short period of time – 2 years after surgery – the VAS and WOMAC pain scores were significantly worse in the group with fixed tibial platform ( p < 0.05 and p < 0.001, respectively). At that time, the worst pain scores had a negative influence on quality of life in patients undergoing TKA with a fixed tibial platform.

Concurrently, it is noted paradoxically that, exactly in this period with 2 years of follow-up, the groups had the best functional capacity scores, both in the SF-36 quality of life questionnaire assessments and in the WOMAC questionnaire functional assessments, with no statistically significant differences between the fixed and mobile groups.

Although TKA has already been shown to be a successful procedure for treating patients with osteoarthritis, a significant percentage can still experience pain after surgery. 25 Although the results of randomized controlled trials are not yet conclusive to determine whether the type of implant can influence postoperative knee pain, the data obtained in the present study suggest that, in 2 years of follow-up, the SF-36 pain domain had less influence on quality of life in the group of patients submitted to TKA with a mobile tibial platform when compared to the group submitted to total prosthesis with fixed platform.

Aglietti et al 24 suggested that the advantages of a project with mobile tibial support may diminish over time. This is also observed in the present study, in which, after 2 years of surgery, it seems that the pain scores align again, with no statistically significant differences between the groups with 4 and 8 years in terms of pain levels. However, as anterior knee pain is relevant for patients even in the short term, it is not believed that this constitutes a limitation for the use of TKA with a mobile platform.

The highlight of the present study is the fact that all surgeries were performed by the same surgeon, with experience in both types of TKA, minimizing bias factors. In addition, follow-up is medium to long term, with a larger sample size than most previous studies. In order to reduce the application bias, the questionnaires were completed by the patients themselves, with the help of the evaluator. Assessments were always performed by a physical therapist who did not know which group the patients had been randomized to.

As a limitation of this analysis, we can mention the nondivision of patients according to the ROM prior to the surgical and final procedure. Also, no radiological analysis was carried out in order to assess the advantages of one implant over the other in relation to the loosening aspect, which was not an objective of the present research.

When idealizing the present study, the focus was to find out if there were functional and quality of life differences in a group of elderly people with knee osteoarthritis who underwent both types of TKA. However, during its realization, some questions arose and remain unanswered, needing to be investigated.

Conclusion

The data from the present study demonstrate that 2 years after the surgery, pain scores in the questionnaires (SF-36, VAS and WOMAC) were worse in the fixed platform TKA group. However, individuals who underwent TKA with a fixed tibial platform did not present any functional and quality of life differences compared with those who underwent arthroplasty with a mobile tibial platform, with a medium-term follow-up.

Footnotes

Conflito de Interesses Os autores declaram não haver conflito de interesses.

Referências

  • 1.Lanza I R, Towse T F, Caldwell G E, Wigmore D M, Kent-Braun J A. Effects of age on human muscle torque, velocity, and power in two muscle groups. J Appl Physiol (1985) 2003;95(06):2361–2369. doi: 10.1152/japplphysiol.00724.2002. [DOI] [PubMed] [Google Scholar]
  • 2.Narici M V, Maganaris C, Reeves N. Myotendinous alterations and effects of resistive loading in old age. Scand J Med Sci Sports. 2005;15(06):392–401. doi: 10.1111/j.1600-0838.2005.00458.x. [DOI] [PubMed] [Google Scholar]
  • 3.Herzog W, Longino D. The role of muscles in joint degeneration and osteoarthritis. J Biomech. 2007;40 01:S54–S63. doi: 10.1016/j.jbiomech.2007.03.001. [DOI] [PubMed] [Google Scholar]
  • 4.Laborde J M, Powers M J. Life satisfaction, health control orientation, and illness-related factors in persons with osteoarthritis. Res Nurs Health. 1985;8(02):183–190. doi: 10.1002/nur.4770080212. [DOI] [PubMed] [Google Scholar]
  • 5.Downe-Wamboldt B. Coping and life satisfaction in elderly women with osteoarthritis. J Adv Nurs. 1991;16(11):1328–1335. doi: 10.1111/j.1365-2648.1991.tb01561.x. [DOI] [PubMed] [Google Scholar]
  • 6.Dickstein R, Heffes Y, Shabtai E I, Markowitz E. Total knee arthroplasty in the elderly: patients' self-appraisal 6 and 12 months postoperatively. Gerontology. 1998;44(04):204–210. doi: 10.1159/000022011. [DOI] [PubMed] [Google Scholar]
  • 7.Heck D A, Robinson R L, Partridge C M, Lubitz R M, Freund D A. Patient outcomes after knee replacement. Clin Orthop Relat Res. 1998;(356):93–110. doi: 10.1097/00003086-199811000-00015. [DOI] [PubMed] [Google Scholar]
  • 8.Bachmeier C J, March L M, Cross M J. A comparison of outcomes in osteoarthritis patients undergoing total hip and knee replacement surgery. Osteoarthritis Cartilage. 2001;9(02):137–146. doi: 10.1053/joca.2000.0369. [DOI] [PubMed] [Google Scholar]
  • 9.Hartley R C, Barton-Hanson N G, Finley R, Parkinson R W. Early patient outcomes after primary and revision total knee arthroplasty. A prospective study. J Bone Joint Surg Br. 2002;84(07):994–999. doi: 10.1302/0301-620x.84b7.12607. [DOI] [PubMed] [Google Scholar]
  • 10.Mäntyselkä P, Kumpusalo E, Ahonen R, Takala J. Patients' versus general practitioners' assessments of pain intensity in primary care patients with non-cancer pain. Br J Gen Pract. 2001;51(473):995–997. [PMC free article] [PubMed] [Google Scholar]
  • 11.Janse A J, Gemke R J, Uiterwaal C S, van der Tweel I, Kimpen J L, Sinnema G. Quality of life: patients and doctors don't always agree: a meta-analysis. J Clin Epidemiol. 2004;57(07):653–661. doi: 10.1016/j.jclinepi.2003.11.013. [DOI] [PubMed] [Google Scholar]
  • 12.O'Boyle C A. Assessment of quality of life in surgery. Br J Surg. 1992;79(05):395–398. doi: 10.1002/bjs.1800790506. [DOI] [PubMed] [Google Scholar]
  • 13.Givon U, Ginsberg G M, Horoszowski H, Shemer J. Cost-utility analysis of total hip arthroplasties. Technology assessment of surgical procedures by mailed questionnaires. Int J Technol Assess Health Care. 1998;14(04):735–742. doi: 10.1017/s0266462300012046. [DOI] [PubMed] [Google Scholar]
  • 14.Ethgen O, Bruyère O, Richy F, Dardennes C, Reginster J Y. Health-related quality of life in total hip and total knee arthroplasty. A qualitative and systematic review of the literature. J Bone Joint Surg Am. 2004;86(05):963–974. doi: 10.2106/00004623-200405000-00012. [DOI] [PubMed] [Google Scholar]
  • 15.Ware J, Jr, Kosinski M, Keller S DA. A 12-Item Short-Form Health Survey: construction of scales and preliminary tests of reliability and validity. Med Care. 1996;34(03):220–233. doi: 10.1097/00005650-199603000-00003. [DOI] [PubMed] [Google Scholar]
  • 16.Wylde V, Learmonth I, Potter A, Bettinson K, Lingard E. Patient-reported outcomes after fixed- versus mobile-bearing total knee replacement: a multi-centre randomised controlled trial using the Kinemax total knee replacement. J Bone Joint Surg Br. 2008;90(09):1172–1179. doi: 10.1302/0301-620X.90B9.21031. [DOI] [PubMed] [Google Scholar]
  • 17.Jacobs W, Anderson P, Limbeek J, Wymenga A. Mobile bearing vs fixed bearing prostheses for total knee arthroplasty for post-operative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev. 2004;(02):CD003130. doi: 10.1002/14651858.CD003130.pub2. [DOI] [PubMed] [Google Scholar]
  • 18.Núñez M, Núñez E, del Val J L. Health-related quality of life in patients with osteoarthritis after total knee replacement: factors influencing outcomes at 36 months of follow-up. Osteoarthritis Cartilage. 2007;15(09):1001–1007. doi: 10.1016/j.joca.2007.02.019. [DOI] [PubMed] [Google Scholar]
  • 19.Kirkwood B R, Sterne J A. Massachusetts, USA: Blackwell; 2006. Essential medical statistics. 2nd ed. [Google Scholar]
  • 20.McCullagh P, Nelder J A. New York, USA: Chapman and Hall; 1989. Generalized linear models. 2nd ed. [Google Scholar]
  • 21.Neter J, Kutner M H, Nachtsheim C J, Wasserman W. Ilinois: Richard D. Irwing; 1996. Applied Linear Statistical Models. 4th ed. [Google Scholar]
  • 22.Bhan S, Malhotra R, Kiran E K, Shukla S, Bijjawara M. A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am. 2005;87(10):2290–2296. doi: 10.2106/JBJS.D.02221. [DOI] [PubMed] [Google Scholar]
  • 23.Matsuda S, Mizu-uchi H, Fukagawa S. Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2010;18(10):1311–1316. doi: 10.1007/s00167-010-1143-z. [DOI] [PubMed] [Google Scholar]
  • 24.Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L. Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty. 2005;20(02):145–153. doi: 10.1016/j.arth.2004.09.032. [DOI] [PubMed] [Google Scholar]
  • 25.Hofmann S, Seitlinger G, Djahani O, Pietsch M. The painful knee after TKA: a diagnostic algorithm for failure analysis. Knee Surg Sports Traumatol Arthrosc. 2011;19(09):1442–1452. doi: 10.1007/s00167-011-1634-6. [DOI] [PubMed] [Google Scholar]
Rev Bras Ortop (Sao Paulo). 2020 Jul 8;56(1):53–60. [Article in Portuguese]

Estudo comparativo da função e qualidade de vida de pacientes submetidos à artroplastia total do joelho com plataformas tibiais fixa e móvel

Resumo

Objetivo  Comparar a função e qualidade de vida dos pacientes submetidos a artroplastia total de joelho (ATJ) com plataforma tibial fixa e plataforma tibial móvel.

Métodos  Foram avaliados 240 pacientes com diagnóstico de osteoartrose de joelho, em um ensaio clínico, randomizados em dois grupos: grupo A, composto por 120 pacientes submetidos a ATJ com plataforma tibial fixa, e grupo B, formado por 120 pacientes com plataforma móvel. Todos foram avaliados de acordo com a função e qualidade de vida pelos questionários de Western Ontario and McMaster Universities Arthritis Index (WOMAC) e Short Form Health Survey(SF-36), e escores de dor, por meio da escala visual analógica (EVA) de dor, no pré-operatório e com 6meses, 1ano, 2anos, 4anos e 8anos de cirurgia.

Resultados  Com relação aos diversos domínios do SF-36, o comportamento médio dos escores de capacidade funcional, aspectos físicos, dor e aspectos emocionais foram estatisticamente diferentes ao longo do seguimento, em ambos os grupos. Os demais domínios de qualidade de vida não apresentaram diferenças. Assim como na EVA de dor, o escore médio do WOMAC de dor apresentou melhora ao longo do seguimento em ambos os grupos. Entretanto, com dois anos de seguimento, foram estaticamente piores no grupo A, se igualando ao grupo B nos outros momentos de acompanhamento.

Conclusão  Com 2anos de pós-operatório, os escores de dor do WOMAC e daEVA foram piores no grupo submetido aATJ com plataforma tibial fixa. Porém, as diferenças não permaneceram no médioprazo, sugerindo que a artroplastia com plataforma tibial móvel tem uma vantagem no curto prazo, podendo auxiliar no processo de reabilitação.

Palavras-chave: artroplastia do joelho, qualidade de vida, osteoartrose

Introdução

Nas últimas décadas, com o envelhecimento da população geral e as alterações do sistema musculoesquelético decorrentes desse processo, a osteoartrose tem se tornado um importante problema de saúde. 1 2 3 Os sintomas desta doença degenerativa da cartilagem articular levam à incapacidade funcional e perda da qualidade de vida do idoso. 4 5 6 7 8 9 Estes sintomas têm sido elementos de avaliação dos tratamentos, entre eles, a artroplastia total de joelho (ATJ). 10 11

Os métodos para avaliar os resultados da ATJ são: as taxas de mortalidade, morbidade, complicações e durabilidade. Entretanto, com o crescimento rápido de melhorias nos procedimentos, essas taxas já não refletem o real benefício na qualidade de vida do indivíduo. 12 13 14 Dessa forma, as avaliações com questionários genéricos ou específicos referentes ao tratamento têm fornecido informações valiosas. Destaca-se, entre eles, o Western Ontario and McMaster Universities Arthritis Index(WOMAC) para a ATJ, e o Short Form Health Survey(SF-36) para avaliar a qualidade de vida. 10 15 Estes questionários têm mostrado os bons resultados da ATJ na melhora da função e qualidade de vida de pacientes idosos.

A ATJ pode ser dividida de acordo com o componente tibial em dois tipos: ATJ com plataforma fixa e com plataforma móvel. Segundo Wyldeet al, 16 a ATJ padrão –com plataforma fixa– pode levar a uma carga excessiva na região posterior do componente tibial, aumentando o desgaste do polietileno, acarretando maior risco de falha e necessidade de revisão. Dessa forma, as ATJs com plataforma móvel, por permitirem maior mobilidade rotatória e melhor congruência do componente de polietileno, possuem a vantagem teórica de se autoalinhar, reduzindo a incidência de dor anterior no joelho, produzindo melhor função.

Visto isso, as vantagens teóricas da ATJ com plataforma móvel devem ser confirmadas clinicamente, já que, até agora, não há consenso em relação aos melhores resultados, e estudos anteriores foram considerados de baixa qualidade. 17

O objetivo do presente estudo é comparar a função e qualidade de vida dos pacientes que foram submetidos à ATJ com plataformas fixa e móvel.

Métodos

Todos os procedimentos foram aprovados pelo comitê de ética em pesquisa da nossa universidade.

Este é um ensaio clínico randomizado, duplo-cego, realizado no período de janeiro de 2004 a janeiro de 2007. Os critérios de inclusão foram: 1–idade entre 55 e 70 anos, 2–sinais e sintomas clínicos compatíveis com osteoartrose do joelho, 3–sinais radiográficos de osteoartrose tricompartimental graus III, IV e V de Ahlback modificada por Keyes e Goodfellow, 4–Ausência de doenças associadas acometendo membros inferiores, 5–Ausência de distúrbio neurológico, 6–Ausência de lesões nervosas ou fraturas prévias nos membros inferiores. Os critérios de não-inclusão foram: 1–infecção, 2–deformidade de flexão > 10°, 3–desvios angulares em varo e valgo > 25°, 4–defeito focal tumoral, 5–condições físicas que eliminariam o suporte de implante adequado, 6–doença coexistente com risco à vida no ano seguinte ao procedimento. Pacientes que se disseram incapazes ou não deram certeza de retornar para acompanhamento foram excluídos do estudo.

Após avaliação clínica e radiológica completa, os pacientes com indicação para ATJ que preenchiam os critérios foram convidados a participar do estudo. Os que confirmaram a participação assinaram o termo de consentimento livre e esclarecido. O método de randomização utilizado foi a permuta em blocos, com o objetivo de manter uma distribuição semelhante do número de pacientes em cada grupo estudado. Blocos de oito pacientes foram criados, com diferentes combinações. Envelopes lacrados, opacos e numerados de 1 a 240 continham o grupo ao qual cada paciente pertencia:oprimeiro grupo (grupo A), submetido à ATJ com plataforma tibial fixa (DepuySynthes, Warsaw, IN, EUA), e o segundo grupo (grupo B), submetido à ATJ com plataforma tibial móvel (LCS, DepuySynthes, Warsaw, IN, EUA).

Todos os pacientes foram avaliados com questionários no pré-operatório e no pós-operatório com 6, 24, 48 e 96 meses com relação à função (WOMAC), qualidade de vida (SF-36) e percepção subjetiva da dor (Escala visual analógica de dor [EVA]).

Tamanho da Amostra

Para aceitar um risco alfa de 0.05 e um risco β de 0.20, 98 pacientes foram necessários para cada grupo para detectar uma diferença ≥ 08 pontos entre a média de pontuações pré e pós-operatórias para as dimensões de dor e função por meio do questionário de WOMAC, julgada uma diferença clinicamente importante. 18 Um desvio padrão (DP) comum de 20 foi assumido. A amostra foi superestimada em 20% para permitir eventuais perdas, de tal forma que cada grupo deveria conter 120 pacientes.

Técnica Cirúrgica

Todas as próteses foram implantadas pelo mesmo cirurgião. Em todos os pacientes, realizou-se bloqueio anestésico do tipo raquimedular. Por 48horas, foi utilizada antibioticoterapia profilática com cefazolina sódica. Garrote pneumático foi usado rotineiramente. A via de acesso foi a anterior com artrotomia parapatelar medial. A patela foi evertida e substituída em todos os casos. Ambas as próteses tinham o componente femoral similar e todas eram estabilizadas posteriormente. Ambos os ligamentos cruzados foram extraídos. Realizava-se primeiro o corte ósseo tibial, horizontal, usando guia extramedular para tíbia e intramedular para o fêmur. Todos os componentes foram cimentados. Utilizou-se dreno de sucção por 24horas de rotina. Para a profilaxia tromboembólica, por 14 dias, os pacientes receberam heparina de baixo peso molecular.

Reabilitação

Preconizou-se uma rápida mobilização, em que, no primeiro dia de pós-operatório, foram realizados exercícios metabólicos de tornozelo e exercícios isométricos para quadríceps. No segundo dia de pós-operatório, depois de retirado o dreno de sucção, iniciou-se o treino de marcha com andador e descarga de peso em ambos os membros. O treino de marcha foi realizado de acordo com a tolerância de cada paciente (dor e condições clínicas). Todos os pacientes realizaram sessões de uma hora de movimento passivo continuo (CPM), duas vezes ao dia (manhã e tarde), e o ângulo de movimento variava de acordo com a tolerância à dor de cada um. A alta hospitalar foi dada em média com 5dias de pós-operatório e quando o paciente atingisse próximo dos 90° de flexão do joelho e conseguisse deambular independentemente com muletas ou andador. As sessões de fisioterapias ambulatoriais começaram 1semana após a alta hospitalar. O programa de reabilitação ambulatorial durou em média 2meses, sendo semelhantes para os 2grupos.

Avaliação Clínica

Realizou-se a avaliação da função por meio do WOMAC, sendo composto por três domínios: função, dor e rigidez. A soma dos pontos de cada domínio forma o resultado final, variando de 0 a 68. Para avaliar a qualidade de vida, foi usado o SF-36, variando de 0 a 100, apresentando 36 itens de resposta, envolvendo 8 conceitos: capacidade funcional, aspecto físico, dor, estado geral de saúde, vitalidade, aspectos sociais, aspectos emocionais e saúde mental. Aplicou-se também a EVA, variando de 0 a 10.

Análises Estatísticas

Foi verificada a existência de associação entre os tipos de prótese e as características com uso de testes qui-quadrado. 19 As características quantitativas dos pacientes foram descritas segundo os tipos de prótese com uso de medidas resumo (média, DP, mediana e quartis, P25 e P75) e comparadas entre os grupos com uso de análise de testes t de Student. 19 Os escores das escalas avaliadas foram descritos segundo os tipos de prótese em cada momento de avaliação e comparados entre os tipos de prótese e momentos com uso de análises de equações de estimação generalizadas com distribuição marginal normal e função de ligação logarítmica, devido à assimetria de distribuição dos escores, supondo correlação autorregressiva de primeira ordem entre os momentos de avaliação. 20 As análises foram seguidas de comparações múltiplas de Bonferroni 21 para comparar os grupos e momentos, quando significativas as diferenças nos escores. As análises foram realizadas com os dados avaliados nos pacientes, mesmo considerando perdas durante o seguimento. Os resultados foram ilustrados com gráficos de perfis médios, com os respectivos errospadrão, tendo sido os testes realizados com nível de significância de 5%.

Resultados

Os pacientes foram recrutados consecutivamente de novembro de 2011 até dezembro de 2012. No total, 1.268 pacientes foram avaliados e 1.028 foram excluídos, resultando em uma amostra final de 240 pacientes. Os pacientes foram randomizados em 2grupos: 120 na ATJ com plataforma fixa e 120 na ATJ com plataforma móvel. Do grupo com plataforma fixa, cinco pacientes evoluíram para óbito, e seis não aderiram. Do grupo com plataforma móvel, seis evoluíram para óbito, quatro não aderiram, um teve acidente vascular cerebral (AVC)e um teve ruptura do ligamento patelar. Todos os óbitos ocorreram após > 2 anos de seguimento ( Figura 1 ).

Fig. 1.

Fig. 1

Fluxograma de fases.

Dos 240 pacientes randomizados, 6do grupo com plataforma fixa e 5do grupo com plataforma móvel apresentaram complicações. No grupo com plataforma fixa, tivemos três casos de infecção, dois com embolia e um com trombose venosa profunda. No grupo com plataforma móvel, tivemos dois casos de infecção, um de trombose venosa profunda, um de AVCe um com ruptura do ligamento patelar.

As idades dos indivíduos da amostra foram compreendidas entre 59 e 70 anos, com média de 65,7 anos (DP = 3,7). Eram do gênero feminino 81%, com índice de massa corporal (IMC) de 30 (DP =4,7). As características pessoais avaliadas não apresentaram associação ou diferenças estatisticamente significantes;portanto, os grupos foram homogêneos, como mostra a Tabela 1 .

Tabela 1. Descrição das características pessoais dos pacientes segundo tipos de prótese e resultados dos testes estatísticos.

Variável Tipo de prótese Total ( N  = 240) valor-p
Fixa ( N  = 120) Móvel ( N  = 120)
Gênero, n (%)
Feminino 96 (80) 100 (83,3) 196 (81,7) 0,505*
Masculino 24 (20) 20 (16,7) 44 (18,3)
Ladooperado, n (%)
Direito 64 (53,3) 57 (47,5) 121 (50,4) 0,366*
Esquerdo 56 (46,7) 63 (52,5) 119 (49,6)
Idade (anos)
média (DP) 65,9 (3,9) 65,4 (3,4) 65,7 (3,7) 0,369
mediana (P25; P75) 66 (63; 70) 65 (63; 68) 65 (63; 69)
Peso (Kg)
média (DP) 78,4 (12,1) 80,3 (13,5) 79,4 (12,8) 0,276
mediana (P25; P75) 78,5 (73; 85) 78,5 (71; 87) 78,5 (72; 86)
Altura (m)
média (DP) 1,62 (0,06) 1,62 (0,14) 1,62 (0,10) 0,320
mediana (P25; P75) 1,63 (1,6; 1,66) 1,63 (1,57; 1,67) 1,63 (1,59; 1,67)
IMC (Kg/m2)
média (DP) 29,7 (4,2) 30,2 (5,1) 30 (4,7) 0,426
mediana (P25; P75) 29,5 (27,2; 32,3) 30,1 (27,2; 33,1) 29,7 (27,2; 32,9)

Abreviações: DP, desvio padrão; IMC, índice de massa corporal.

Teste t de Student; * Teste qui-quadrado.

No que diz respeito aos diversos domínios do questionário de qualidade de vida do SF-36, não foi mostrada diferença entre os grupos na qualidade de vida ao final do seguimento. Apenas em alguns domínios observa-se diferença entre os grupos, em determinados momentos. Um exemplo está no escore de dor em 1e 2anos de seguimento, mas que parece igualar nos demais momentos.

A Tabela 2 mostra que o comportamento médio dos escores de capacidade funcional, dor e aspectos emocionais foram estatisticamente diferentes ao longo do seguimento nos grupos de pacientes, conforme os valores realçados na tabela. Os demais domínios de qualidade de vida apresentaram diferenças médias apenas ao longo do seguimento, nos diferentes momentos de avaliação, porém sem diferença entre os grupos.

Tabela 2. Descrição dos escores de qualidade de vida segundo tipos de prótese e momentos de avaliação e resultados estatísticos.

Variável Momento Tipo de prótese valor-p Tipo de prótese valor-p Momento valor-p Interação
Fixa Móvel
Média DP N Média DP N
Capacidade Funcional Pré 20,22 18,10 120 17,17 14,79 120 0,219 <0,001 0,019
6 meses 57,54 19,47 120 62,79 19,39 120
1 ano 65,46 15,38 120 74,42 17,32 120
2 anos 68,37 16,76 120 73,88 16,71 120
4 anos 61,63 15,46 120 63,88 15,14 120
8 anos 51,46 16,72 120 55,46 16,09 120
Aspectos Físicos Pré 13,48 26,58 120 17,23 25,76 120 0,910 <0,001 0,536
6 meses 71,68 28,24 120 67,86 37,68 120
1 ano 77,08 24,38 120 73,96 31,49 120
2 anos 88,27 65,30 120 82,75 29,13 120
4 anos 84,77 23,00 120 75,43 35,65 120
8 anos 78,93 25,52 120 78,34 28,06 120
Dor Pré 41,89 26,12 120 35,34 22,69 120 0,053 <0,001 0,004
6 meses 80,19 26,03 120 79,39 23,79 120
1 ano 75,41 30,97 120 86,20 18,29 120
2 anos 69,63 34,84 120 92,49 86,12 120
4 anos 76,72 28,09 120 81,05 19,50 120
8 anos 74,07 27,78 120 85,28 62,49 120
Estado Geral de Saúde Pré 69,58 18,19 120 71,60 16,32 120 0,512 <0,001 0,167
6 meses 77,96 13,10 120 80,53 12,77 120
1 ano 78,10 12,54 120 76,38 15,23 120
2 anos 76,18 12,89 120 72,29 18,29 120
4 anos 77,21 14,26 120 75,18 15,45 120
8 anos 74,88 14,10 120 73,51 14,69 120
Vitalidade Pré 68,03 18,79 120 68,45 19,16 120 0,366 <0,001 0,779
6 meses 78,64 14,60 120 78,14 15,10 120
1 ano 79,49 13,16 120 77,23 16,89 120
2 anos 78,36 14,18 120 75,43 17,09 120
4 anos 78,85 14,14 120 77,98 15,59 120
8 anos 79,56 16,12 120 77,98 15,93 120
Aspectos Sociais Pré 45,90 26,75 120 50,80 27,66 120 0,062 <0,001 0,080
6 meses 81,65 23,33 120 86,17 20,40 120
1 ano 84,28 23,08 120 87,68 20,49 120
2 anos 85,06 21,43 120 84,22 23,49 120
4 anos 83,60 22,30 120 84,38 24,01 120
8 anos 78,95 25,64 120 87,13 20,68 120
Aspectos Emocionais Pré 52,68 45,09 120 40,26 45,11 120 0,771 <0,001 0,036
6 meses 73,54 36,84 120 81,40 35,59 120
1 ano 79,74 34,68 120 86,65 29,79 120
2 anos 92,98 109,76 120 86,61 30,13 120
4 anos 86,88 90,35 120 86,08 29,47 120
8 anos 81,36 30,33 120 87,21 27,42 120
Saúde Mental Pré 71,04 20,07 120 73,81 18,15 120 0,317 <0,001 0,484
6 meses 77,27 17,25 120 76,85 16,31 120
1 ano 76,87 17,04 120 77,20 13,12 120
2 anos 75,05 19,15 120 75,99 14,34 120
4 anos 75,09 19,65 120 78,43 14,58 120
8 anos 73,58 19,55 120 75,90 16,25 120

Abreviação: DP, desvio padrão.

Na Tabela 3 , a EVA de dor e os escores de dor do WOMAC apresentaram, em média, comportamento estatisticamente diferente entre os grupos ao longo do seguimento ( p < 0,001). No escore de função e rigidez do WOMAC, houve diferença média estatisticamente significante apenas ao longo do seguimento, nos diferentes momentos de avaliação, sem diferença entre os grupos ( p < 0,001).

Tabela 3. Descrição da escala visual analógicade dor e dos escores de funcionalidade segundo os tipos de prótese e momentos de avaliação e resultados estatísticos.

Variável Momento Tipo de prótese valor-p Tipo de prótese valor-p Momento valor-p Interação
Fixa Móvel
Média DP N Média DP N
EVA de Dor Pré 84,69 17,04 120 85,40 17,49 120 0,016 <0,001 <0,001
6 meses 26,43 22,13 120 24,70 22,43 120
1 ano 25,63 15,08 120 20,53 20,85 120
2 anos 28,83 19,40 120 16,57 18,97 120
4 anos 14,06 17,39 120 13,04 18,07 120
8 anos 13,78 16,37 120 10,56 16,59 120
WOMAC de Dor Pré 13,60 3,86 120 14,04 3,42 120 0,032 <0,001 <0,001
6 meses 3,46 3,53 120 3,42 3,82 120
1 ano 3,86 3,30 120 2,67 3,91 120
2 anos 5,11 3,97 120 2,86 4,01 120
4 anos 2,91 3,06 120 2,24 3,92 120
8 anos 2,31 3,21 120 1,77 3,72 120
WOMAC função Pré 43,64 13,91 120 45,36 12,60 120 0,037 <0,001 0,001
6 meses 14,11 11,78 120 10,94 9,45 120
1 ano 9,62 9,81 120 8,53 7,79 120
2 anos 8,83 9,81 120 7,11 7,39 120
4 anos 13,12 9,81 120 10,13 7,96 120
8 anos 21,37 10,90 120 18,31 8,47 120
WOMAC rigidez Pré 4,40 2,43 120 5,01 2,34 120 0,198 <0,001 0,203
6 meses 1,38 1,66 120 1,31 1,40 120
1 ano 0,98 1,49 120 0,99 1,25 120
2 anos 0,88 1,49 120 0,58 1,00 120
4 anos 0,94 1,43 120 0,63 1,02 120
8 anos 0,93 1,49 120 0,68 1,04 120

Abreviação: DP, desvio padrão; EVA, escala visual analógica; WOMAC, Western Ontario andMcMasterUniversitiesArthritis Index.

Discussão

O presente estudo prospectivo, randomizado e controlado constatou que, com 8anos de pós-operatório, não houve diferenças significativas no desfecho clínico dor dos questionários de qualidade de vida SF-36 e WOMAC, bem como nas pontuações da EVA após cirurgias de próteses de joelho com plataforma tibial fixa em relação aos implantes de plataforma móvel. Recentes estudos randomizados prospectivos 16 22 23 também não conseguiram constatar diferença na evolução clínica, análise radiológica ou sobrevivência entre as próteses fixa e móvel. Esses mesmos autores compararam os resultados clínicos dos dois tipos de implante no mesmo paciente e não encontraram diferenças nos escores de dor e amplitude de movimento articular (ADM) com 5anos de seguimento. Aglietti et al, 24 em seu estudo sobre pacientes submetidos a artroplastia unilateral de joelho que compara os dois tipos de próteses, também não observaram diferenças significativas com 3anos de seguimento nos escores de dor, embora maior flexão tenha sido apontada em joelhos com plataforma tibial fixa. É possível que a falta de diferença nos resultados clínicos após 8 anos de seguimento encontrados no presente estudo entre implantes com plataforma fixa e plataforma móvel deveu-se às características dos participantes, principalmente no que tange a faixa etária.

Além disso, o instrumento genérico para avaliação da qualidade de vida do SF-36 de pacientes nesta faixa etária contribui para confirmar estes resultados, mas nos parece insuficiente quando usado de maneira isolada para estabelecer conclusões do ponto de vista clínico. Quando analisada a dor, alguns pacientes confundem-se, pois, a questão relaciona-se com “dor no corpo.” Tanto as questões de dor, como aspectos emocionais, disposição, vitalidade, foram frequentemente respondidas positivamente, mas praticamente em todos os casos houve dificuldade para relacionarem a resposta diretamente ao joelho, por serem questões de abrangência maior.

A média de idade dos participantes do presente estudo foi de 65,7 (DP =3,7) anos, e a maioria não realizava atividades físicas de recreação ou esportivas que demandassem maior grau de movimento articular. Segundo Wylde et al, 16 a prótese de suporte tibial móvel foi concebida para proporcionar uma maior amplitude de movimento articular e permitir a participação em atividades que exijam uma maior mobilidade do joelho em todos os planos. Portanto, pode-se argumentar que o implante de apoio tibial móvel do joelho não atingiu seu pleno potencial nesse grupo de pacientes por tratar-se de estudo de uma população mais velha. Um ensaio clínico randomizado envolvendo pacientes mais jovens e mais ativos poderia revelar alguma vantagem funcional de um desenho sobre o outro.

Um achado importante deste estudo a destacar é o fato de que, em curto seguimento de tempo –2anos após a cirurgia, os escores de dor da EVA e WOMAC foram significativamente piores no grupo com plataforma tibial fixa ( p < 0,05 e p < 0,001, respectivamente). Nesse momento, os piores escores de dor influenciaram negativamente na qualidade de vida em pacientes submetidos a ATJ com plataforma tibial fixa.

Ao mesmo tempo, nota-se paradoxalmente que, exatamente nesse período com 2anos de seguimento, os grupos tiveram os melhores escores da capacidade funcional, tanto nas avaliações do questionário de qualidade de vida SF-36 como nas avaliações funcionais do questionário de WOMAC, sem diferenças estatísticas significantes entre os grupos fixa e móvel.

Apesar de a ATJ já ter demonstrado ser um procedimento bem-sucedido para o tratamento de pacientes com osteoartrose, uma percentagem significativa ainda pode experimentar dor após a cirurgia. 25 Embora os resultados dos ensaios clínicos randomizados ainda não serem conclusivos para determinar se o tipo de implante pode influenciar na dor no joelho pós-operatória, os dados obtidos no presente estudo sugerem que, em 2anos de seguimento, o domínio dor do SF-36 influenciou menos na qualidade de vida no grupo de submetidos a ATJ com plataforma tibial móvel quando comparado ao grupo submetido à prótese total com plataforma fixa.

Aglietti et al 24 sugeriam que as vantagens de um projeto com apoio tibial móvel podem diminuir ao longo do tempo. Também se observa isso no presente estudo, em que, após 2anos de cirurgia, parece que os escores de dor se alinham novamente, não se registrando diferenças estatísticas significantes entre os grupos com 4 e 8 anos quanto aos níveis de dor. No entanto, como dor anterior do joelho é relevante para os pacientes mesmo num curto prazo, não se acredita que isso configure uma limitação para uso das ATJ com plataforma móvel.

Destaca-se como ponto forte deste estudo o fato de que todas as cirurgias foram realizadas pelo mesmo cirurgião, com experiência nos dois tipos de ATJ, minimizando os fatores de viés. Além disso, o seguimento é de médio a longo prazo, com um tamanho de amostra maior do que da maioria dos estudos anteriores. A fim de se reduzir o viés da aplicação, os questionários foram preenchidos pelos próprios pacientes, com ajuda do avaliador. As avaliações em todos os momentos foram realizadas por um fisioterapeuta que não sabia para qual grupo os pacientes tinham sido randomizados.

Como limitação da presente análise, pode-se citar a não divisão dos pacientes de acordo com a ADM prévia ao procedimento cirúrgico e final. Também não se realizou a análise radiológica no sentido de aferir vantagens de um implante sobre o outro com relação ao aspecto soltura, o que não era um objetivo da presentepesquisa.

Ao idealizar o presente estudo, o foco principal era averiguar se existiam diferenças funcionais e na qualidade de vida em um grupo de idosos com osteoartrose de joelho submetidos aos dois tipos de ATJ. No entanto, durante sua realização, algumas indagações surgiram e permanecem sem resposta, necessitando ser investigadas.

Conclusão

Os dados do presente estudo demonstram que com 2anos de pós-operatório os escores de dor nos questionários SF-36, EVA e WOMAC foram piores no grupo ATJ plataforma fixa. Porém, os indivíduos submetidos à ATJ com plataforma tibial fixa não apresentaram diferenças funcionais e na qualidade de vida em comparação àqueles submetidos à artroplastia com plataforma tibial móvel, com seguimento de médio prazo.


Articles from Revista Brasileira de Ortopedia are provided here courtesy of Sociedade Brasileira de Ortopedia e Traumatologia

RESOURCES