Abstract
Background
SYNERGY is a thin-strut, platinum-chromium metal alloy stent with an ultrathin abluminal everolimus-eluting bioabsorbable polymer. EVOLVE II was a global randomized controlled trial that enrolled 1,684 patients treated with either a SYNERGY or durable polymer PROMUS Element Plus (PE+) everolimus-eluting stent, including 155 patients from Japanese sites. This substudy analyzed 5-year clinical outcomes in the Japanese and non-Japanese cohorts.
Methods and Results
Patients aged ≥18 years with ≤3 native coronary artery lesions (reference vessel diameter ≥2.25–≤4.00 mm; length ≤34 mm) in ≤2 major vessels were randomized 1 : 1 to receive either SYNERGY (n=74 patients in Japan) or PE+ (n=81 patients in Japan). Five-year target lesion failure (TLF) was observed in 8.3% SYNERGY- and 11.2% PE+-treated patients (P=0.54). There were no cardiac deaths, and rates of target lesion revascularization and myocardial infarction were comparable between treatment arms. One patient in the SYNERGY arm experienced a very late definite stent thrombosis (ST); no ST occurred in the PE+ arm (P=0.30). Despite differences in baseline clinical and lesion characteristics, the 5-year TLF rates were not significantly different in SYNERGY-treated patients either in (8.3%) or outside (14.8%) Japan (P=0.14).
Conclusions
In Japanese patients with coronary artery disease, SYNERGY showed comparable efficacy to PE+, with low rates of adverse events over 5 years. Similarly, 5-year clinical outcomes were favorable in Japanese vs. non-Japanese patients implanted with SYNERGY.
Key Words: Bioabsorbable polymer, Coronary artery disease, Everolimus-eluting stent
Drug-eluting stents (DES) with antiproliferative drugs delivered from a durable polymer have significantly reduced angiographic and clinical measures of restenosis compared with bare metal stents.1,2 However, the permanent presence of a durable polymer coating on DES may delay arterial healing, induce local inflammation, and increase the risk of stent thrombosis (ST).2,3 Recent stent technologies incorporate a biodegradable polymer that leaves behind a bare metal platform after complete resorption, thereby offering the potential of improved arterial healing and reduced occurrence of late or very late ST. Clinical data from these new-generation DES have shown promising results, including reduced rates of revascularization and thrombotic events.4–7
The thin-strut platinum-chromium SYNERGY stent (Boston Scientific Corporation, Marlborough, MA, USA) has an abluminal coating of everolimus in an ultrathin bioabsorbable poly-D,L-lactide-proglyolide co-glycolide (PLGA) polymer.8,9 Everolimus is released over a period of approximately 90 days and the polymer is completely degraded shortly thereafter (∼120 days),10 which may promote rapid arterial healing. The EVOLVE II randomized controlled trial (RCT) demonstrated non-inferiority of SYNERGY to the durable polymer PROMUS Element everolimus-eluting stent for 1-year target lesion failure (TLF).11 Comparable outcomes were maintained through 5 years of follow-up, including a favorably low incidence of ST.11
Previous studies have reported differences in stent deployment techniques and medical management in Japan, particularly greater use of post-dilatation and higher balloon pressure than in other countries.12,13 In addition, due to potential differences in lifestyle (medical history, food, weight, body mass index [BMI]), ethnicities and patient demographics, it is important to investigate the clinical impact of bioabsorbable polymer DES in a Japanese population. This paper describes the final 5-year outcomes in the Japanese cohort of the EVOLVE II RCT after implantation of either the SYNERGY or PROMUS Element Plus stents.
Methods
Study Design and Patient Selection
EVOLVE II was a prospective multicenter single-blinded non-inferiority RCT that enrolled patients worldwide. Detailed methods of the RCT have been described previously.14 Briefly, patients aged ≥18 years with ≤3 native coronary lesions in ≤2 major epicardial vessels (reference vessel diameter ranging from ≥2.25 to ≤4.0 mm and lesion length ≤34 mm) were enrolled. Eligible patients had target lesion stenosis ≥50% and <100% with Thrombolysis in Myocardial Infarction (TIMI) flow >1 and/or a stenosis ≥70%, abnormal fractional flow reserve, elevated cardiac biomarkers, or an abnormal stress or imaging stress test. Patients with left main disease, chronic total occlusion, ST-elevation myocardial infarction (STEMI), vein graft disease, or in-stent restenosis were excluded. After meeting the study selection criteria, patients were randomized 1 : 1 to SYNERGY or PROMUS Element Plus stents.
This study was approved by the institutional review board at each site prior to enrollment and complied with the principles of the Declaration of Helsinki, the US Food and Drug Administration’s Guidance for Industry E6 Good Clinical Practice: Consolidated Guidance, and all applicable local and federal regulations. The EVOLVE II RCT is registered with Clinicaltrials.gov (ID: NCT01665053).
Device Description and Procedure
The SYNERGY stent consists of a thin strut (74–81 μm), platinum-chromium platform coated abluminally with an ultrathin (4 µm) bioabsorbable everolimus-eluting (100 µm/cm2) PLGA polymer. Everolimus is eluted within 3 months and PLGA degrades within 4 months, leaving behind the biologically inert bare metal platform.10 The control stent used in the EVOLVE II RCT was a durable polymer PROMUS Element Plus everolimus-eluting platinum-chromium coronary stent.15 The study device and implantation procedure have been described previously.8
Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 inhibitor was prescribed for a minimum of 6 months after the procedure (1 year in patients not at high risk of bleeding). An independent core laboratory evaluated all baseline and follow-up angiograms (Beth Israel Deaconess Medical Center, Boston, MA, USA). Clinical follow-up was required in hospital and 30 days and 6, 12, and 18 months after PCI, and then annually between 2 and 5 years.
Study Endpoints
The primary endpoint of the EVOLVE II RCT was 12-month TLF (ischemia-driven target lesion revascularization [TLR], target vessel-related myocardial infarction [TV-MI], or cardiac death).14,16 Additional prespecified clinical endpoints of target vessel revascularization (TVR), target vessel failure (TVF; composite of ischemia-driven TVR, TV-MI, or cardiac death related to the target vessel), all-cause death, myocardial infarction (MI; third universal definition),17 and Academic Research Consortium (ARC)-defined ST17 were evaluated over a 5-year follow-up period. A clinical events committee reviewed and adjudicated all major adverse events. Technical success rate was defined as successful delivery and deployment of the study stent to the target vessel, without balloon rupture or stent embolization, with a post-procedure diameter stenosis of <30% and TIMI 3 flow in the target lesion (as assessed visually by the treating physician). Clinical procedural success was defined as post-procedural diameter stenosis <30%, TIMI 3 flow in all target lesions, and the absence of in-hospital MI, TVR, or cardiac death.
Statistical Analysis
Clinical outcomes were evaluated by the Kaplan-Meier method. Hazard ratios (HRs) and P values were evaluated using the Wald confidence interval (CI) and log-rank test, respectively. Discrete variables are reported as percentages (%), and the significance of differences was assessed using Chi-squared or Fisher exact tests. Continuous variables are provided as the mean±SD and were compared using Student’s t-test. Statistical analyses were conducted using SAS® Version 9.0 (SAS Institute, Cary, NC, USA).
Results
Patients and Clinical Follow-up
The EVOLVE II RCT enrolled 1,684 patients at 125 sites globally. Of these patients, 155 were Japanese: 74 randomized to the SYNERGY arm and 81 randomized to the PROMUS Element Plus arm (Figure 1). Clinical follow-up at 5 years was completed in 97% SYNERGY- and 96% PROMUS Element Plus stent-treated patients. In all, 772 non-Japanese patients were implanted with the SYNERGY stent and 720 patients had follow-up data available at 5 years (Figure 1).
Figure 1.
EVOLVE II (Japan) enrollment and follow-up. *Includes investigator discretion, patient withdrew consent, and missed visit. pts, patients; RCT, randomized control trial.
In Japanese patients, the baseline clinical and quantitative coronary angiographic lesion characteristics were well balanced between the treatment arms (Table 1). The mean age was 67 years, approximately 75% were male, 30% had diabetes, and 16% had prior MI. More than 15% of patients in each treatment group had 2 target lesions treated and approximately 82% were classified as American Heart Association/American College of Cardiology Type B2 or C lesions by core laboratory-adjudicated angiography (Table 1). The rates of technical and clinical procedural success were similar between treatment groups (Table 2). Other procedural variables and post-procedural angiographic outcomes were well matched between the subgroups (Table 2). As indicated in Table 3, DAPT (aspirin plus a P2Y12 inhibitor) and aspirin use at 5 years was similar between the SYNERGY (41% and 100%, respectively) and PROMUS Element Plus (30% and 95%, respectively) arms.
Table 1.
Baseline Characteristics
| PROMUS Element Plus (n=81 patients) |
SYNERGY (n=74 patients) |
P value | |
|---|---|---|---|
| Baseline characteristics | |||
| Male sex | 74.1 (60/81) | 77.0 (57/74) | 0.67 |
| Age (years) | 66.83±9.91 (81) | 67.42±12.02 (74) | 0.74 |
| BMI (kg/m2) | 24.75±3.37 (81) | 25.07±3.40 (74) | 0.56 |
| Medical history | |||
| Current smoker | 23.5 (19/81) | 14.9 (11/74) | 0.18 |
| Diabetes | 29.6 (24/81) | 29.7 (22/74) | 0.99 |
| Hyperlipidemia | 82.7 (67/81) | 75.7 (56/74) | 0.28 |
| Hypertension | 72.8 (59/81) | 79.7 (59/74) | 0.31 |
| Unstable angina | 11.1 (9/81) | 12.2 (9/74) | 0.84 |
| Myocardial infarction | 16.0 (13/81) | 14.9 (11/74) | 0.84 |
| Congestive heart failure | 19.8 (16/81) | 18.9 (14/74) | 0.89 |
| Multivessel disease | 28.8 (23/80) | 29.7 (22/74) | 0.89 |
| Previous PCI | 38.3 (31/81) | 41.9 (31/74) | 0.65 |
| Peripheral vascular disease | 1.2 (1/81) | 5.4 (4/74) | 0.19 |
| Silent ischemia | 21.8 (17/78) | 23.3 (17/73) | 0.83 |
| Target vessel treatedA | |||
| No. lesions | 99 | 85 | |
| LAD | 46.5 (46/99) | 47.1 (40/85) | 0.94 |
| LCx | 17.2 (17/99) | 20.0 (17/85) | 0.62 |
| RCA | 36.4 (36/99) | 32.9 (28/85) | 0.63 |
| Target lesions treated | 1.22±0.42 (81) | 1.15±0.36 (74) | 0.24 |
| 2 lesions | 22.2 (18/81) | 14.9 (11/74) | 0.24 |
| Target lesion characteristicsA | |||
| RVD (mm) | 2.65±0.49 (99) | 2.71±0.44 (85) | 0.32 |
| <2.25 mm | 22.2 (22/99) | 15.3 (13/85) | 0.23 |
| MLD (mm) | 0.86±0.31 (99) | 0.91±0.27 (85) | 0.23 |
| Diameter stenosis (%) | 67.16±11.18 (99) | 66.19±9.08 (85) | 0.53 |
| Lesion length (mm) | 15.85±7.05 (99) | 16.86±8.28 (85) | 0.37 |
| Modified ACC/AHA Type B2/C | 76.8 (76/99) | 87.1 (74/85) | 0.07 |
Intent-to-treat analysis. Values are given as percentages (n/N) or as the mean±SD. P values were calculated using Student’s t-tests for continuous variables and the Chi-squared test for discrete variables. APer lesion. ACC/AHA, American College of Cardiology/American Heart Association; BMI, body mass index; LAD, left anterior descending; LCx, left circumflex; MLD, minimum lumen diameter; PCI, percutaneous coronary intervention; RVD, reference vessel diameter.
Table 2.
Procedural and Post-Procedural Characteristics
| PROMUS Element Plus (n=99 lesions, n=81 patients) |
SYNERGY (n=86 lesions, n=74 patients) |
P value | |
|---|---|---|---|
| Procedural characteristics | |||
| Technical successA (%) | 99.0 | 100 | 1.00 |
| Clinical procedural successB (%) | 96.3 | 97.3 | 1.00 |
| No. stents per patientB | 1.23±0.43 | 1.19±0.39 | 0.49 |
| No. stents per target lesionA | 1.01±0.10 | 1.02±0.15 | 0.48 |
| Total stent length implantedA (mm) | 23.31±8.08 | 23.28±7.93 | 0.97 |
| PredilatationA (%) | 100.0 | 100.0 | Undefined |
| Post-dilatationA (%) | 78.8 | 62.8 | 0.02 |
| Maximum pressure overallA (atm) | 16.11±3.00 | 14.93±3.57 | 0.02 |
| Post-procedural characteristics | |||
| MLD (mm) | |||
| In-stent | 2.47±0.44 | 2.52±0.40 | 0.42 |
| In-segment | 2.11±0.46 | 2.18±0.41 | 0.28 |
| Diameter stenosis (%) | |||
| In-stent | 6.63±8.61 | 7.24±7.95 | 0.62 |
| In-segment | 20.85±7.91 | 20.13±8.14 | 0.55 |
| Acute gain (mm) | |||
| In-stent | 1.61±0.46 | 1.61±0.41 | 0.98 |
| In-segment | 1.25±0.48 | 1.27±0.43 | 0.79 |
Intent-to-treat analysis. Unless indicated otherwise, data are given as the mean±SD. P values were calculated using Student’s t-tests for continuous variables and the Chi-squared test for discrete variables. APer lesion. BPer patient. MLD, minimum lumen diameter.
Table 3.
Antiplatelet Medications Throughout the 5-Year Follow-up
| PROMUS Element Plus (n=81 patients) |
SYNERGY (n=74 patients) |
P value | |
|---|---|---|---|
| Aspirin | |||
| At discharge | 100.0 (81/81) | 100.0 (74/74) | Undefined |
| 1 year | 100.0 (81/81) | 100.0 (73/73) | Undefined |
| 2 years | 96.2 (76/79) | 97.2 (70/72) | 1.00* |
| 3 years | 96.2 (76/79) | 100.0 (71/71) | 0.25* |
| 4 years | 97.4 (76/78) | 100.0 (70/70) | 0.49* |
| 5 years | 94.7 (72/76) | 100.0 (69/69) | 0.12* |
| Dual antiplatelet therapy | |||
| At discharge | 100.0 (81/81) | 100.0 (74/74) | Undefined |
| 1 year | 91.4 (74/81) | 86.3 (63/73) | 0.32 |
| 2 years | 49.4 (39/79) | 48.6 (35/72) | 0.93 |
| 3 years | 43.0 (34/79) | 45.1 (32/71) | 0.80 |
| 4 years | 38.5 (30/78) | 44.3 (31/70) | 0.47 |
| 5 years | 30.3 (23/76) | 40.6 (28/69) | 0.19 |
Intent-to-treat subjects. Values show the percentage (n/N). *P values derived from Fisher’s exact test; all other P values are derived from Chi-square tests. Dual antiplatelet therapy consisted of aspirin and one of clopidogrel, ticlopidine, prasugrel, or ticagrelor.
Baseline and lesion characteristics were well matched between Japanese and non-Japanese patients implanted with SYNERGY, except that Japanese patients were older (67 vs. 63 years; P=0.0007), had a lower BMI (25 vs. 30 kg/m2; P<0.0001), a lower frequency of unstable angina (12% vs. 36%; P<0.0001), a greater history of congestive heart failure (18.9% vs. 7.3%; P=0.0005), highly complex lesions (87.1% vs. 75.9%; P=0.02), and longer lesions (17 vs. 14 mm; P=0.0004; Supplementary Table 1). Procedural and post-procedural characteristics were similar in Japanese and non-Japanese patients (Supplementary Table 2). However, Japanese patients had significantly longer stents (23.3 vs. 21.3 mm; P=0.05), a greater number of stents (1.3 vs. 1.2; P=0.05), and lower maximum overall pressure (14.9 vs. 16.1 atm; P=0.0009) than non-Japanese patients (Supplementary Table 2). There were no significant between-group differences in the use of DAPT and aspirin at 5 years (Supplementary Table 3).
Clinical Events
As reported previously, the primary endpoint of 12-month TLF was met in the EVOLVE II RCT: SYNERGY was non-inferior to PROMUS Element Plus for 1-year TLF (6.7% vs. 6.5%, respectively; Pnon-inferiority=0.0005).14 Kaplan-Meier curves for TLF over the 5-year period were similar for both the SYNERGY and PROMUS Element Plus stents (8.3% vs. 11.2%, respectively; HR 0.73; 95% CI 0.26–2.04; P=0.54; Figure 2A) in the EVOLVE II Japanese patients. Landmark analyses demonstrated comparable TLF rates at 1 year, as well as between 1 and 5 years (Figure 2B). There were no differences in the rates of individual components of TLF at the 5-year follow-up (Figure 3). Additional clinical endpoints listed in Table 4 were low and comparable between arms. One patient in the SYNERGY arm experienced a very late (>1 year) definite ST; no ST occurred in the PROMUS Element Plus arm (P=0.30).
Figure 2.

Target lesion failure (TLF) in the EVOLVE II (Japan) randomized control trial. (A) Cumulative Kaplan-Meier curves for TLF over the 5-year follow-up period. (B) Landmark analysis of TLF at 1 year and between 1 and 5 years. P values were calculated using log-rank tests. Hazard ratios (HRs) are given with 95% confidence intervals in square brackets. PE+, PROMUS Element Plus.
Figure 3.
Kaplan-Meier curves for individual components of target lesion failure (TLF) in the EVOLVE II (Japan) randomized control trial. (A) Cardiac death, (B) target vessel-related myocardial infarction (TV-MI), and (C) target lesion revascularization (TLR) over the 5-year follow-up period. P values were calculated using log-rank tests. Hazard ratios (HRs) are given with 95% confidence intervals in square brackets. PE+, PROMUS Element Plus.
Table 4.
Clinical Outcomes at 5 Years
| PROMUS Element Plus (n=81 patients) |
SYNERGY (n=74 patients) |
HR (95% CI) | P value | |
|---|---|---|---|---|
| All-cause death/MI | 7.5 (6) | 15.0 (11) | 2.05 (0.76, 5.55) | 0.15 |
| Death | 2.5 (2) | 4.1 (3) | 1.67 (0.28, 9.98) | 0.57 |
| Cardiac death | 0.0 (0) | 0.0 (0) | NA (NA, NA) | Undefined |
| Non-cardiac death | 2.5 (2) | 4.1 (3) | 1.67 (0.28, 9.98) | 0.57 |
| MI | 7.5 (6) | 11.1 (8) | 1.49 (0.52, 4.30) | 0.45 |
| TV-MI | 5.0 (4) | 5.5 (4) | 1.10 (0.27, 4.38) | 0.89 |
| Q-wave | 0.0 (0) | 2.7 (2) | NA (NA, NA) | 0.14 |
| TV-Q-wave | 0.0 (0) | 2.7 (2) | NA (NA, NA) | 0.14 |
| Non-Q-wave | 7.5 (6) | 8.4 (6) | 1.10 (0.35, 3.40) | 0.87 |
| TV-non-Q-wave | 5.0 (4) | 2.7 (2) | 0.54 (0.10, 2.94) | 0.47 |
| TVR | 8.8 (7) | 12.7 (9) | 1.43 (0.53, 3.84) | 0.47 |
| TLR | 7.5 (6) | 4.2 (3) | 0.54 (0.14, 2.17) | 0.38 |
| TLF | 11.2 (9) | 8.3 (6) | 0.73 (0.26, 2.04) | 0.54 |
| TVF | 12.5 (10) | 15.4 (11) | 1.21 (0.52, 2.86) | 0.66 |
| Definite or probable ST | 0.0 (0) | 1.4 (1) | NA (NA, NA) | 0.29 |
| Definite ST | 0.0 (0) | 1.4 (1) | NA (NA, NA) | 0.29 |
| Probable ST | 0.0 (0) | 0.0 (0) | NA (NA, NA) | Undefined |
Intent-to-treat subjects. Unless indicated otherwise, values show the percentage (n). Time-to-event analysis. P values are derived from long-rank tests. Target vessel failure (TVF) was defined as target vessel revascularization (TVR), target vessel-related myocardial infarction (TV-MI), or death related to the target vessel. CI, confidence interval; HR, hazard ratio; MI, myocardial infarction; NA, not available; ST, stent thrombosis; TLF, target lesion failure; TV, target vessel related.
Kaplan-Meier curves for TLF occurrence throughout the 5-year follow-up were similar between SYNERGY Japanese and non-Japanese patients (8.3% vs. 14.8%, respectively; HR 0.54; 95% CI 0.24–1.23; P=0.14; Figure 4). The individual rates of cardiac death, TV-MI, and TLR were similar between groups (Figure 4). Additional prespecified outcomes throughout the 5-year follow-up are provided in Supplementary Table 4. Definite ST occurred in 1 SYNERGY Japanese and 4 SYNERGY non-Japanese patients (P=0.38; Supplementary Table 4).
Figure 4.
Kaplan-Meier curves for target lesion failure (TLF) and individual components over the 5-year follow-up period in SYNERGY Japanese and non-Japanese patients. (A) TLF, (B) target vessel-related myocardial infarction (TV-MI), (C) target lesion revascularization (TLR), and (D) cardiac death. P values were calculated using log-rank tests. Hazard ratios (HRs) are given with 95% confidence intervals in square brackets.
Discussion
The present study describes outcomes in the Japanese cohort of the EVOLVE II RCT that compared the SYNERGY and PROMUS Element Plus stents. The data are in line with those reported previously for the overall EVOLVE II RCT,11 where both stents exhibited similar clinical efficacy and safety. The principle outcomes of the present subanalysis are that rates of the primary clinical endpoint, TLF, were relatively low and comparable for both stent types at 1 and 5 years. Second, there were no cardiac deaths and the rates of TV-MI and TLR were not significantly different between treatment arms. Third, no ST was observed in Japanese patients treated with PROMUS Element Plus and only 1 very late ST was seen with SYNERGY. Fourth, despite baseline differences in patient and lesion characteristics, clinical events, including TLF, mortality, MI and ST, throughout the 5-year follow-up were comparable in Japanese and non-Japanese patients implanted with SYNERGY.
The use of DES in percutaneous coronary intervention (PCI) has shown improved clinical outcomes; however, the presence of a permanent polymer is associated with local inflammation and impaired stent healing.18,19 New stent technologies incorporate antiproliferative drugs eluting from a bioabsorbable polymer, offering the potential of enhanced arterial healing, improved clinical outcomes, and a reduced incidence of late or very late ST. The SYNERGY stent incorporates platinum-chromium metal alloy struts with an ultrathin PLGA everolimus-eluting polymer applied only to the abluminal surface. Animal studies have shown that drug release and PLGA absorption from the SYNERGY stent are completed within 4 months, leaving behind a biocompatible bare metal platform.10 Preclinical data have shown facilitated endothelial recovery and reduced thrombogenicity following SYNERGY stent implantation compared with the thick-strut bioabsorbable biolimus-eluting stent.20 These preclinical benefits further translate into clinical benefits, as seen in the EVOLVE series of trials demonstrating low and comparable event rates with permanent vs. bioabsorbable polymer DES over 5 years.11,21
The short-term safety and efficacy of bioabsorbable polymer DES compared with durable polymer DES have been well established in recent large-scale “all-comers” randomized trials. The BIO-RESORT trial demonstrated non-inferiority of bioabsorbable polymer SYNERGY (everolimus-eluting) and Orsiro (sirolimus-eluting) stents compared with the durable polymer Resolute Integrity (zotarolimus-eluting) stent for the occurrence of 1-year TVF.6 Furthermore, 3-year results from the BIO-RESORT trial showed a similar trend regarding the rate of the primary composite endpoint of TVF.7 The incidence of definite ST was <1.0% in the SYNERGY arm of both trials. In addition, an analysis from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR) comparing SYNERGY-treated patients with those treated with a new-generation DES showed a low rate of ST at 1 year (0.4% vs. 0.5%; P=0.17).4 In the SORT-OUT VIII trial, SYNERGY was non-inferior to the bioabsorbable polymer Biomatrix NeoFlex (biolimus-eluting) stent with respect to the primary endpoint of 1-year TLF (4.0% vs. 4.4%; P<0.001).22 In a recently conducted meta-analysis that included data from the EVOLVE first in human21 and EVOLVE II11 randomized trials, bioabsorbable stents demonstrated similar safety and efficacy compared with durable stents.23 The rate of definite or probable ST was numerically lower with bioabsorbable than durable polymer stents (0.98% vs. 1.15%), although this difference was not statistically significant (P=0.19).23
The potential clinical benefits of a bioabsorbable polymer stent would be expected to accrue slowly over time (>1 year). Therefore, long-term follow-up of trials using this new stent technology is important. Five-year outcomes between bioabsorbable polymer and durable polymer DES were similar in the EVOLVE,21 COMPARE II,24 ISAR-TEST 4,25 and LEADERS26 trials. Importantly, data from the present analysis are consistent with the overall EVOLVE II RCT, demonstrating no significant differences between the 2 stent types in the 5-year rates of revascularization, MI, death, and ST.
Despite similar inclusion and exclusion criteria, there were some baseline differences between Japanese and non-Japanese patients treated with SYNERGY, which may be attributed to differences in lifestyle, race, and/or nationality. Consistent with prior reports, Japanese patients in this study tended to be older and had a lower BMI and lower incidence of unstable angina than non-Japanese patients.12,13 In addition, Japanese patients had a greater history of congestive heart failure and highly complex and longer lesions than non-Japanese patients. Regardless of these observed differences, the 5-year clinical outcomes did not differ significantly between cohorts.
Study Limitations
Although the present substudy is a RCT, it only included a small cohort of patients in Japan. Patients with high complexity were excluded, and therefore this analysis does not fully represent real-world clinical practice. Analysis in the Japanese cohort was prespecified, but the sample size may have limited the ability to assess clinical complications like ST. Moreover, differences in baseline and procedural characteristics between Japanese and non-Japanese cohorts may have affected the 5-year outcomes. Finally, this substudy was not powered to detect differences between Japanese and non-Japanese cohorts.
Conclusions
This substudy provides the longest follow-up data in Japanese patients implanted with the SYNERGY stent. Final 5-year data demonstrate low and comparable clinical outcomes between the SYNERGY and PROMUS Element Plus stents. Japanese and non-Japanese patients implanted with the SYNERGY stent experienced similarly low rates of adverse events at 5 years. These data support the long-term safety and efficacy of SYNERGY in Japanese patients undergoing PCI.
Sources of Funding
This study was funded by Boston Scientific Corporation.
Disclosures
T.K. has received research grants from Boston Scientific Corporation. K.K. has received lecture fees from Boston Scientific Corporation. M.N. has received honoraria from Daiichi Sankyo, Bayer, Terumo, and Japan Lifeline. T.U. has received consulting fees and honoraria from Bayer, Daiichi Sankyo, Nipro, and Mochida. D.J.A. is a full-time employee with equity interest in Boston Scientific Corporation. N.H., S.Y., and T.U. are members of Circulation Reports’ Editorial Team. The remaining authors have no conflicts of interest to disclose.
IRB Information
This study was approved by the Western Institutional Review Board (Reference no. IRB00000533).
Supplementary Files
Supplementary Table 1. Baseline Characteristics of SYNERGY Japanese and Non-Japanese Patients Supplementary Table 2. Procedural and Post-Procedural Characteristics Supplementary Table 3. Antiplatelet Medications Through 5-Year Follow-up Supplemental Table 4. Clinical Outcomes at 5 Years
Acknowledgments
The authors thank Pooja Bhatt, PhD, and Songtao Jiang, MSc (Boston Scientific Corporation), for assistance with manuscript preparation and statistical analysis.
Data Availability
The data for this clinical trial, including any deidentified patient data, will not be shared.
References
- 1. Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, et al.. 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. Am J Coll Cardiol 2011; 58: e44–e122. [DOI] [PubMed] [Google Scholar]
- 2. Palmerini T, Benedetto U, Biondi-Zoccai G, Della Riva D, Bacchi-Reggiani L, Smits PC, et al.. Long-term safety of drug-eluting and bare-metal stents: Evidence from a comprehensive network meta-analysis. Am J Coll Cardiol 2015; 65: 2496–2507. [DOI] [PubMed] [Google Scholar]
- 3. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al.. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. Am J Coll Cardiol 2006; 48: 193–202. [DOI] [PubMed] [Google Scholar]
- 4. Sarno G, Lagerqvist B, Olivecrona G, Varenhorst C, Danielewicz M, Hambraeus K, et al.. Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Catheter Cardiovasc Interv 2017; 90: 881–887. [DOI] [PubMed] [Google Scholar]
- 5. Kang SH, Chae IH, Park JJ, Lee HS, Kang DY, Hwang SS, et al.. Stent thrombosis with drug-eluting stents and bioresorbable scaffolds: Evidence from a network meta-analysis of 147 trials. JACC Cardiovasc Interv 2016; 9: 1203–1212. [DOI] [PubMed] [Google Scholar]
- 6. von Birgelen C, Kok MM, van der Heijden LC, Danse PW, Schotborgh CE, Scholte M, et al.. Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): A three-arm, randomised, non-inferiority trial. Lancet 2016; 388: 2607–2617. [DOI] [PubMed] [Google Scholar]
- 7. Kok MM, Zocca P, Buiten RA, Danse PW, Schotborgh CE, Scholte M, et al.. Two-year clinical outcome of all-comers treated with three highly dissimilar contemporary coronary drug-eluting stents in the randomised BIO-RESORT trial. EuroIntervention 2018; 14: 914–923. [DOI] [PubMed] [Google Scholar]
- 8. Meredith IT, Verheye S, Dubois CL, Dens J, Fajadet J, Carrié D, et al.. Primary endpoint results of the EVOLVE trial: A randomized evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent. Am J Coll Cardiol 2012; 59: 1362–1370. [DOI] [PubMed] [Google Scholar]
- 9. Meredith IT, Verheye S, Weissman NJ, Barragan P, Scott D, Valdes Chavarri M, et al.. Six-month IVUS and two-year clinical outcomes in the EVOLVE FHU trial: A randomised evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting stent. EuroIntervention 2013; 9: 308–315. [DOI] [PubMed] [Google Scholar]
- 10. Wilson GJ, Marks A, Berg KJ, Eppihimer M, Sushkova N, Hawley SP, et al.. The SYNERGY biodegradable polymer everolimus eluting coronary stent: Porcine vascular compatibility and polymer safety study. Catheter Cardiovasc Interv 2015; 86: e247–e257. [DOI] [PubMed] [Google Scholar]
- 11. Kereiakes DJ, Windecker S, Lee JR, Mehta SR, Sarembock IJ, Feldman RL, et al.. Clinical outcomes following implantation of thin-strut, bioabsorbable polymer-coated, everolimus-eluting SYNERGY stents. Circ Cardiovasc Interv 2019; 12: e008152. [DOI] [PubMed] [Google Scholar]
- 12. Saito S, Hagiwara N, Seki A, Igarashi K, Muramatsu T, Yajima J, et al.. Japanese and non-Japanese patient outcomes in the PLATINUM randomized trial comparing the PROMUS Element and XIENCE V everolimus-eluting stents. J Cardiol 2014; 64: 105–112. [DOI] [PubMed] [Google Scholar]
- 13. Saito S, Nakamura S, Fujii K, Nakamura M, Isshiki T, Hirayama H, et al.. Mid-term results of everolimus-eluting stent in a Japanese population compared with a US randomized cohort: SPIRIT III Japan Registry with harmonization by doing. J Invasive Cardiol 2012; 24: 444–450. [PubMed] [Google Scholar]
- 14. Kereiakes DJ, Meredith IT, Windecker S, Jobe RL, Mehta SR, Sarembock IJ, et al.. Efficacy and safety of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent: The EVOLVE II randomized trial. Circ Cardiovasc Interv 2015; 8: e002372. [DOI] [PubMed] [Google Scholar]
- 15. Stone GW, Teirstein PS, Meredith IT, Farah B, Dubois CL, Feldman RL, et al.. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: The PLATINUM trial. Am J Coll Cardiol 2011; 57: 1700–1708. [DOI] [PubMed] [Google Scholar]
- 16. Kereiakes DJ, Meredith IT, Masotti M, Carrié D, Moreno R, Erglis A, et al.. Safety and efficacy of a bioabsorbable polymer-coated, everolimus-eluting coronary stent in patients with diabetes: The EVOLVE II diabetes substudy. EuroIntervention 2017; 12: 1987–1994. [DOI] [PubMed] [Google Scholar]
- 17. Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al.. Clinical end points in coronary stent trials: A case for standardized definitions. Circulation 2007; 115: 2344–2351. [DOI] [PubMed] [Google Scholar]
- 18. Nakazawa G, Nakano M, Otsuka F, Wilcox JN, Melder R, Pruitt S, et al.. Evaluation of polymer-based comparator drug-eluting stents using a rabbit model of iliac artery atherosclerosis. Circ Cardiovasc Interv 2011; 4: 38–46. [DOI] [PubMed] [Google Scholar]
- 19. Byrne RA, Joner M, Kastrati A.. Polymer coatings and delayed arterial healing following drug-eluting stent implantation. Minerva Cardioangiol 2009; 57: 567–584. [PubMed] [Google Scholar]
- 20. Koppara T, Cheng Q, Yahagi K, Mori H, Sanchez OD, Feygin J, et al.. Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents. Circ Cardiovasc Interv 2015; 8: e002427. [DOI] [PubMed] [Google Scholar]
- 21. Meredith IT, Verheye S, Dubois C, Dens J, Farah B, Carrié D, et al.. Final five-year clinical outcomes in the EVOLVE trial: A randomised evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting stent. EuroIntervention 2018; 13: 2047–2050. [DOI] [PubMed] [Google Scholar]
- 22. Maeng M, Christiansen EH, Raungaard B, Kahlert J, Terkelsen CJ, Kristensen SD, et al.. Everolimus-eluting versus biolimus-eluting stents with biodegradable polymers in unselected patients undergoing percutaneous coronary intervention: A randomized noninferiority trial with 1-year follow-up (SORT OUT VIII Trial). JACC Cardiovasc Interv 2019; 12: 624–633. [DOI] [PubMed] [Google Scholar]
- 23. El-Hayek G, Bangalore S, Casso Dominguez A, Devireddy C, Jaber W, Kumar G, et al.. Meta-analysis of randomized clinical trials comparing biodegradable polymer drug-eluting stent to second-generation durable polymer drug-eluting stents. JACC Cardiovasc Interv 2017; 10: 462–473. [DOI] [PubMed] [Google Scholar]
- 24. Vlachojannis GJ, Smits PC, Hofma SH, Togni M, Vázquez N, Valdés M, et al.. Biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with coronary artery disease: Final 5-year report from the COMPARE II trial (abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent). JACC Cardiovasc Interv 2017; 10: 1215–1221. [DOI] [PubMed] [Google Scholar]
- 25. Kufner S, Byrne RA, Valeskini M, Schulz S, Ibrahim T, Hoppmann P, et al.. Five-year outcomes from a trial of three limus-eluting stents with different polymer coatings in patients with coronary artery disease: Final results from the ISAR-TEST 4 randomised trial. EuroIntervention 2016; 11: 1372–1379. [DOI] [PubMed] [Google Scholar]
- 26. Serruys PW, Farooq V, Kalesan B, de Vries T, Buszman P, Linke A, et al.. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: Final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial. JACC Cardiovasc Interv 2013; 6: 777–789. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Supplementary Table 1. Baseline Characteristics of SYNERGY Japanese and Non-Japanese Patients Supplementary Table 2. Procedural and Post-Procedural Characteristics Supplementary Table 3. Antiplatelet Medications Through 5-Year Follow-up Supplemental Table 4. Clinical Outcomes at 5 Years
Data Availability Statement
The data for this clinical trial, including any deidentified patient data, will not be shared.



