Skip to main content
Journal of Geriatric Cardiology : JGC logoLink to Journal of Geriatric Cardiology : JGC
. 2021 Feb 28;18(2):91–93. doi: 10.11909/j.issn.1671-5411.2021.02.008

Left main bifurcation stenting: the impact of strut thickness on long-term outcomes

Gianluca Rigatelli 1,*, Marco Zuin 2
PMCID: PMC7940968  PMID: 33747057

Over the latest years, both randomized controlled trials (RCTs) and observational studies have provided solid basis for percutaneous coronary intervention as a treatment option for unprotected left main (LM) bifurcation coronary artery disease. A recent meta-analysis comparing the long-term outcome between LM bifurcation disease one-stent technique versus two-stent technique, the study has demonstrated that one-stent strategy resulted associated with both major adverse cardiac events and target lesion revascularizations (TLRs) lower rates but resulted equivalent to two-stent strategy in terms of cardiovascular mortality, target lesion failure and stent thrombosis (ST) even at one-year and three-year follow-up.[1] However, previous analyses have mainly focused on the type of double stent strategy adopted, as well as bifurcation geometrical properties (i.e., bifurcation angle, side branch length, and etc) or different biodegradable polymer. On the contrary, the impact of stents strut thickness has been generally neglected in current literature.

Cochrane Library, Embase, PubMed and Google Scholar were queried to locate RCTs comparing provisional versus up-front two-stent strategies for LM bifurcations lesions published between January 2004 and November 2020, including only studies clearly defining the type of stent used were included in the analysis. From a total of 287 articles, after excluding duplicates, 92 articles were eligible for review. After comprehensive full-text articles evaluation, three articles were included into our final review.[24]

From our analysis, globally 602 patients (755 males, mean age: 65.3 years) received a dual stenting approach for the treatment of unprotected LM bifurcation lesions, with different technique. Stents struts thickness varied from 140 to 81 µm. At 30 days, only the EXCEL trial[4] showed a cardiovascular death of 2.7%, while the DK crush V[3] and CACTUS trial[2] reported no events in the same follow-up period (Table 1). As showed in the Figure 1A, ST rate decreased with the decreasing of stent struts thickness among the three investigations. Similarly, the rate of TLR, which were available with the same definition in two of three, confirmed a decrease of events using thinner struts (Figure 1B). Notably, both the DK crush V[3] and EXCEL trial[4] also presented an analysis based on three-year follow-up: ST rate remained lower when using thin or ultrathin stents (0.4% vs. 1.6% for the DK crush V and EXCEL trial, respectively) compared when thicker struts stents were used.

1. Summary of the characteristics of the selected studies.

Trial Year Stent used, strut thickness Mean age, yrs Males Double
stenting
techniques
Technique
used
Cardiovascular death Target lesion revascularization Stent thrombosis
Data are presented as means ± SD or n (%).
CACTUS trial[2] 2009 Cypher 65 ± 10 142 (80.2%) 177 Crush 0 1.7% 1.7%
DK crush V[3] 2017 Xience V, Endeavor Resolute, Firebird II 65 ± 9 199 (82.9%) 240 DK crush 0 0.4% 0.4%
EXCEL trial[4] 2018 Xience V 66.8 ± 9.3 141 (76.2%) 185 T, TAP, Culotte, Reverse crush 2.7% NR 1.6%

1.

1

Histogram representation of the stent thromobisis (A) and target lesion revascularization (B) based on strut thicknesses.

The results of published CRTs on the treatment of LM bifurcation lesions seems to enforce the concept that leaving a scarce amount of metal layers at the carina of LM bifurcation after double stenting techniques may result in a more favourable short-term and long-term outcomes.[5] This concept has been recently confirmed by different fluid dynamic analysis, which demonstrated that leaving the few metal at bifurcation significantly improved the rheological properties of the whole LM bifurcation after stenting.[6] It is obvious that from a purely biomechanical and physiologic point of view, a thick strut impairs blood flow rheology much more that a thin strut independently from stent shape and design,[7,8] inducing turbulences of the blood stream, thus increasing the chances of particle recirculation and favoring a nidus for thrombus allocation.[9] These phenomena are intuitively amplificated if long segments of metal layer are crushed or overlapped such as in culotte technique or classical crush or DK crush.[10]

Obviously, different confounders may have a major impact on outcomes and remains difficult to assess the specific contribution of stent thickness, complex stenting techniques and length of the dual antiplatelet therapy in particular on mid-term and long-term target lesion failure and mortality.

However, our observations may represent an additional stimulus to keep open the debate on this issue, evidencing the need of further sub-analysis on existing and future trials in terms of stent struts, to assess the specific contribution of different stenting approaches in these patients.

ACKNOWLEDGMENTS

All authors had no conflicts of interest to disclose.

References

  • 1.Rigatelli G, Zuin M, Nikolov P, et al One-year and three-year outcomes of percutaneous bifurcation left main revascularization with modern drug-eluting stents: a systematic review and meta-analysis. Clin Res Cardiol. 2021;110:1–11. doi: 10.1007/s00392-020-01679-w. [DOI] [PubMed] [Google Scholar]
  • 2.Colombo A, Bramucci E, Saccà S, et al Randomized study of the crush technique versus provisional side-branch stenting in true coronary bifurcations: the CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study. Circulation. 2009;119:71–78. doi: 10.1161/CIRCULATIONAHA.108.808402. [DOI] [PubMed] [Google Scholar]
  • 3.Chen SL, Zhang JJ, Han Y, et al Double kissing crush versus provisional stenting for left main distal bifurcation lesions: DKCRUSH-V randomized trial. J Am Coll Cardiol. 2017;70:2605–2617. doi: 10.1016/j.jacc.2017.09.1066. [DOI] [PubMed] [Google Scholar]
  • 4.Kandzari DE, Gershlick AH, Serruys PW, et al Outcomes among patients undergoing distal left main percutaneous coronary intervention. Circ Cardiovasc Interv. 2018;11:e007007. doi: 10.1161/CIRCINTERVENTIONS. [DOI] [PubMed] [Google Scholar]
  • 5.Beier S, Ormiston J, Webster M, et al Impact of bifurcation angle and other anatomical characteristics on blood flow: a computational study of non-stented and stented coronary arteries. J Biomech. 2016;49:1570–1582. doi: 10.1016/j.jbiomech.2016.03.038. [DOI] [PubMed] [Google Scholar]
  • 6.Rigatelli G, Zuin M, Dash D Thin and crush: the new mantra in left main stenting? World J Cardiol. 2018;10:191–195. doi: 10.4330/wjc.v10.i11.191. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Geith MA, Nothdurfter L, Heiml M, et al Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations. Acta Biomater. 2020;116:285–301. doi: 10.1016/j.actbio.2020.08.016. [DOI] [PubMed] [Google Scholar]
  • 8.Zun PS, Narracott AJ, Evans PC, et al A particle-based model for endothelial cell migration under flow conditions. Biomech Model Mechanobiol. 2020;19:681–692. doi: 10.1007/s10237-019-01239-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Rigatelli G, Zuin M, Dell’Avvocata F, et al Evaluation of potential substrates for restenosis and thrombosis in overlapped versus edge-to-edge juxtaposed bioabsorbable scaffolds: insights from a computed fluid dynamic study. Cardiovasc Revasc Med. 2018;19:273–278. doi: 10.1016/j.carrev.2017.08.005. [DOI] [PubMed] [Google Scholar]
  • 10.Rigatelli G, Zuin M, Dell’Avvocata F, et al Evaluation of coronary flow conditions in complex coronary artery bifurcations stenting using computational fluid dynamics: impact of final proximal optimization technique on different double-stent techniques. Cardiovasc Revasc Med. 2017;18:233–240. doi: 10.1016/j.carrev.2017.01.002. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Geriatric Cardiology : JGC are provided here courtesy of Institute of Geriatric Cardiology, Chinese PLA General Hospital

RESOURCES