Skip to main content
. Author manuscript; available in PMC: 2022 Apr 1.
Published in final edited form as: Anesthesiology. 2021 Apr 1;134(4):607–616. doi: 10.1097/ALN.0000000000003724

Table 3-.

Measured parameters by fluid status: resuscitation and overload phase

Fluid Status: 0 mL 500 mL 1,000 mL 1,500 mL 2,000 mL 2,500 mL P
Vital Sign Parameters
Heart Rate (beats per minute) 99±16 96±14 95±13 95±13 99±9 101±9 0.183
SBP (mmHg) 89±9 89±13 89±15 89±15 91±13 91±12 0.750
DBP (mmHg) 58±11 57±14 57±15 57±14 59±12 59±12 0.700
MAP (mmHg) 72±10 71±14 72±16 72±15 73±13 74±12 0.669
Pulse Pressure (mmHg) 33±6 32±7 32±7 32±7 32±7 32±7 0.421
Pulse Pressure Variation 20±12 16±11 11±3 10±4 8±2 11±7* 0.055
Central Hemodynamic Parameters
MPAP (mmHg) 17±4 20±5* 22±5*** 23±5**** 23±4**** 24±4*** <0.0001
PCWP (mmHg) 8±3 10±3 12±4* 15±3**** 16±3*** 17±3**** <0.0001
CVP (mmHg) 6±4 9±4* 11±4*** 13±4**** 13±4**** 14±4**** <0.0001
CO (L/min) 4.3±1.3 4.4±1.1 4.6±0.88 5.1±1.3 5.1±1.5 5.7±1.0** <0.0001

Values are reported with their standard deviations

P values reflect one-way ANOVA analysis

Relative to 0 milliliters (mL):

*

P<0.05

**

P≤0.01

***

P≤0.001

****

P≤0.0001