Abstract
This paper attempts to compare three methods of testing floor slip resistance and the resulting classifications. Polished, flamed, brushed, and grained granite slabs were tested. The acceptance angle values (αob) obtained through the shod ramp test, slip resistance value (SRV), and sliding friction coefficient (μ) were compared in terms of the correlation between the series, the precision of each method, and the classification results assigned to each of the three obtained indices. It was found that the evaluation of a product for slip resistance was strongly related to the test method used and the resulting classification method. This influence was particularly pronounced for low roughness slabs. This would result in risks associated with inadequate assessments, which could affect the safe use of buildings facilities.
Keywords: slip resistance, granite floor, slip resistance value, ramp test, acceptance angle, sliding friction coefficient, comparability of test methods
1. Introduction
Slip resistance of granite floors is a performance that determines the fulfilment of basic requirement no. 4 (safety and accessibility in use), which, according to Annex I to Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR) [1], is one of the seven basic requirements to be met by construction works as a whole and by their separate parts. The construction works must be designed and built in such a way that they do not present unacceptable risks of accidents or damage in service or in operation, such as slipping.
Individual European countries have defined more or less specific requirements in this respect. In the UK, the criterion used is the pendulum test value (PTV) of at least 36 units [2]. In Germany, a classification based on the acceptable angle value has been developed, expressed in classes from R9 to R13 [3]. In Italy, the value of the dynamic coefficient of friction for which an acceptable threshold of more than 0.4 has been established is considered for evaluation [4]. In Poland, the issue of slip resistance of granite floors in rooms intended for permanent human occupation is regulated by technical conditions that should be met by buildings and their location [4]. They indicate that the surface of entrances to buildings, external and internal stairs and ramps, passageways in the building and floors in rooms intended for human occupancy, and garage floors should be made of materials that do not pose a slipping hazard. Detailed evaluation criteria are further provided in the Ministry of Investment and Development’s guide, indicating a PTV of at least 36 units [5].
The inadequate slip resistance of a floor carries a risk of slipping. According to the Polish Central Statistical Office, it is, together with trips and falls, one of the leading causes of injuries [6]. These data correspond with the results of analyses conducted by Kemmlert and Lundholm [7] on behalf of the Swedish Council for Occupational Safety and Health, which indicated that slips, trips, and falls account for 17–35% of accidents. Their consequences can be very serious, and treatment can be lengthy and expensive. The most common result is a sprain or fracture of a limb, but more severe cases, such as concussion, have also been reported. It is estimated that one in five slip and fall accidents result in injuries that cause at least one month period of incapacity for work. The slip resistance of floors can be considered a socioeconomically relevant problem.
Slip resistance of floors is determined by several factors, including the properties of the material from which the floor is made, the conditions of its use, the psychophysical state of the user, and the properties of footwear [8,9]. Statistical data indicates that accidents due to slipping most often occur in the autumn–winter period, mainly in public buildings [6] where, as indicated by the analysis of contemporary architectural trends, large-format stone or ceramic tiles with high gloss and smooth surface dominate (Figure 1).
One of the most popular flooring solutions used in public facilities, granite slabs, was used for this study. Slabs of medium-grained Strzegom granite, light gray in color and obtained from the Strzegom–Sobótka massif deposits located in the Sudetes Foreland block, were used. Strzegom granite slabs have been used for flooring in buildings such as the Peace Palace in The Hague, the Palace of Culture and Science in Warsaw, the 10th-Anniversary Stadium in Warsaw, the Congress Centre in Berlin, underground stations in Warsaw, Berlin, and Vienna, numerous office and commercial buildings, railroad stations, underground passages, as well as boulevards, bridges, markets, and squares [10].
Evaluation of slip resistance is conducted using a variety of test methods. Consequently, it is expressed in different parameters that form the basis for independent classifications. Among the most popular is the classification based on slip resistance value (SRV; Figure 2), the acceptance angle value determined by the ramp test (Figure 3), and the dynamic friction coefficient (μ) (Figure 4).
Classification based on SRV, also referred to as PTV, was developed by the UK Slip Resistance Group [2] and introduced into the Health and Safety Executive guidelines [11]. It shows the risk of slipping depending on the value of SRV (Figure 2). It is assumed that the probability of slipping on a floor with an SRV ≥ 36 is 1:1,000,000, while it increases up to 1:20 with an SRV < 24 [2].
The values of the acceptance angle (αob) determined by the shod ramp test are the basis for determining the slip resistance class. There are five classes in accordance with DIN 51130 [3]. Solutions classified as R9 have the lowest slip resistance, while those corresponding to class R13 have the highest (Figure 3).
A separate classification was developed based on the value of the dynamic coefficient of friction (μ) (Figure 4). It is assumed that the floors for which the value of μ is higher than 0.75 can be regarded as antislip [12], while μ above 0.4 is regarded as an acceptable value [4].
The classification scales associated with the various slip resistance test methods are not compatible [13,14,15]. The feelings of people walking on the floors are not always reflected by the values of the coefficients obtained by methods using only test equipment, as shown Choi et al.’s work [14]. An additional source of confusion is the fact that subjective evaluations are expressed on a nominal scale, while measurement results (e.g., sliding friction coefficient (µ)) are expressed on ratio or interval scales.
Attempts are being made to create new classification methods. For example, Çoşkun [16] proposed a new sliding risk scale on natural stones surfaces. Cluster analysis was performed by the author using the k-means method. This resulted in a better resolution classification (results were assigned to more classes than in the case of standard methods used). While it would seem appropriate to create a new scale with better resolution that is universal, habits of a particular type of classification and requirements in higher-level documents expressed in the classification scales used in a particular country may prevail in different countries. In view of this, the best way for unification might be to create a matrix of result dependencies and classifications in the existing set, rather than expanding the set.
Following this pattern, this study compares the results attributed to three different classifications. One of the research methods used is a subjective evaluation, but the study results’ obstacle of nominal scale is removed. In the ramp test, the result is expressed in a physical unit of measure (tilt angle expressed in degrees), although its evaluation is typically subjective. The acceptance angle values obtained through the ramp test, slip resistance value, and sliding friction coefficient (μ) are compared in terms of the correlation between the series, the precision of each method, and the classification results assigned to each of the three obtained indices. A full comparison of classifications and the creation of possible conversion factors will be possible after results are obtained for a large group of different materials.
2. Materials and Methods
2.1. Materials
Granite slabs with different processing textures were used for study, namely polished (PO), flamed (PL), brushed (SZ), and grained (GR). Their characteristics, including roughness parameters, are shown in Table 1.
Table 1.
Sample’s Mark | Processing Texture | Roughness Parameters, μm | Surface Characteristics | |||
---|---|---|---|---|---|---|
Sa | Sz | Ra | Rz | |||
PO | polishing | 4.05 | 213.87 | 1.85 | 25.96 | high degree of smoothness, shine |
PL | flaming | 37.28 | 149.19 | 25.93 | 130.47 | appearance close to natural fracture, with clear changes in the surface of the quartz grains caused by temperature and flame |
SZ | brushed | 38.20 | 556.38 | 27.11 | 294.39 | clear roughness with abrasive scratches |
GR | graining | 97.11 | 839.01 | 83.75 | 418.39 | even but rough surface with characteristic regular concaves and convexities |
An Olympus OLS4100 laser scanning digital noncontact microscope (Olympus, Tokyo, Japan) was used to measure roughness parameters. Sa and Ra values, expressing roughness parameters, were determined according to ISO 3274 [17] and ISO 4288 [18]. The use of the noncontact method (laser beam) in the procedure of measuring the parameters of the geometric structure of the surface, especially the roughness profile, significantly improves the accuracy of the measurement by eliminating the effect of rounding the measuring tip used in the contact method. A 5× objective lens was utilized at 864× total magnification in mixed observation mode. Measurement resolution (laser measurement) was 200 nm. The observed area was 2560–320 µm. The raw Ra and Sa values were utilized to obtain bulk surface roughness information. Ra was measured in 10 different regions, with 10 profiles chosen from each region approximately equidistant from one another. Five equidistant measurements were taken along the sample’s length. The sample was then rotated roughly 180°, and a subsequent five additional measurements were taken. The total number of Ra and Sa measurements were arithmetically averaged to obtain the final value of Ra and Sa. To verify the robustness of the method, reproducibility tests were conducted on five samples.
2.2. Slip Resistance Value
The SRV test was conducted using an instrument (WESSEX, Aldershot, UK) referred to as a British pendulum (Figure 5). The test technique used was in compliance with EN 14231 [19], which is in accordance with CEN/TS 16165 [20] Annex C. The test was to determine the energy loss of the slider due to friction against the test surface. A Type 57 (CEN) slider made of 55–61 International Rubber Hardness Degrees (IRHD) rubber (WESSEX, Aldershot, UK) was used, with a width of 76.2 mm and a slid length of 126 mm. The frictional force between the slider and the test surface was determined by measuring the pendulum deflection while the slider was moving using the C scale. Before testing, the instrument was calibrated using reference substrates, namely glass, a reference plate, and polishing paper. Measurements were conducted under dry and wet conditions (after wetting both the sample and the slider with distilled water). The test was conducted on two samples of a given solution, with 10 measurements in dry conditions and 10 measurements in wet conditions taken in each series.
2.3. Ramp Test
Ramp test was performed using the shoe foot method according to CEN/TS 16165 [20] Annex B, corresponding to DIN 51130 [3]. The test was to determine the acceptance angle (αob), which is the maximum angle of the sample in relation to the level at which a person walking on the floor begins to slip. The researchers walked on ramp (Gabrielli SRL, Florence, Italy) in an upright posture, forward and backward. At the same time, the angle of the sample was changed from a horizontal position (Figure 6a) to an angle at which the researcher no longer felt confident and could not continue walking (Figure 6b). The tests were conducted independently by two researchers. The subjectivity of their experiences was reduced using calibration liners, and the resulting corrections were incorporated into the acceptance angle value. Three standard liners were used for the calibration process. The liners’ acceptance angles were 8.7, 17.3, and 27.3°, respectively. Each person walked on each standard liner three times, and the mean calibration acceptance angle values were determined. Each individual correction value Δα was calculated as a difference between the liners’ acceptance angle and the calibration acceptance angles. Each of the individual correction value Δα was less than the critical differences (≤3.0°). If one of the absolute values was greater, the test person in question would be excluded from the test. Correction value (Dj) was calculated from the values obtained from the calibration liners’ values. The calculation of Dj was carried out as follows:
(1) |
The test samples were covered with engine oil during testing, and the researchers wore standardized footwear with properly profiled rubber sole. The contact pressure values in the ramp test hovered around the level (1.8–2.0) N/cm2 when in static state.
2.4. Sliding Friction Coefficient
Sliding friction coefficient (μ) test was performed according to CEN/TS 16165 [20] Annex D. A tribometer (GTE Industrieelelektronik GmbH, Viersen, Germany) equipped with sliders imitating shoe heels, exercising a total contact pressure of 9 ± 1 N/cm2 when in static state, was used (Figure 7). Moving along two intersecting paths with a constant speed of 0.2 m/s, the device recorded the frictional force between the slider and the sample. The dynamic coefficient of friction (μ) was calculated as the quotient of the frictional force and the contact force of the slider on the sample. Two different sets of sliders were used in the study. The first set consisted of three sliders with styrene–butadiene rubber (SBR) with a density of 1.23 g/cm3 and a Shore D hardness of 50. In the second set, the rear slider was made of SBR and the front sliders were made of tanned leather with a density of 1.0 g/cm3 and a Shore D hardness of 60. Prior to testing, the instrument was calibrated with reference substrates, namely glass, high-pressure laminate (HPL), and ceramic tile. Measurements were carried out in dry and wet conditions (after wetting the sample with demineralized water). The test was carried out on two samples of a given type, with 10 measurements in dry conditions and 10 measurements in wet conditions taken for each sample.
3. Results
3.1. Slip Resistance Value
The SRV obtained in this work is summarized in Figure 8 against the arithmetic mean of the profile deviation from the mean line (Ra) expressing the surface roughness. Comparing these results to the criteria developed by the UK Slip Resistance Group [2], it can be concluded that an SRV ≥ 36, which is taken as an indicator of low slip risk (Figure 2), was achieved in dry conditions by all the tested solutions. The SRV depended on the type of treatment texture [21,22]. The lowest SRV value was obtained for PO with Ra equal to 1.85 μm (60 units), followed by PL with Ra equal to 25.9 μm (77 units) and SZ with Ra equal to 27.1 μm (93 units). The highest SRV value was for GR with Ra equal to 83.7 μm (98 units). The increase in Ra was generally accompanied by a nearly proportional increase in SRV for polished, flamed, and brushed slabs. For the grained slabs, the increase in Ra did not fully translate into SRV values. The above may be due to the specific surface profile of the grained slabs. Out of the tested range, only this type of slab has concavities and convexities with a circular shape, which may cause a different adhesion of the slider in the PTV test. As in other works [13,23], a significant reduction in SRV was observed under wet conditions. However, it remained satisfactorily above 36 units for the flamed, brushed, and grained slabs. There was a decrease to 22 units for polished tiles, indicating that the floor poses a very high risk of slipping under these conditions. The SRV results obtained under dry conditions corresponded with the study of Karaca et al. [24], who obtained SRV values ranging from 42 to 74 units for granite slabs with slightly lower roughness than those tested in this study. In contrast, the slip resistance value determined in this study under wet conditions was significantly more favorable. In the aforementioned work, they ranged from 9 to 12 units.
3.2. Ramp Test
The above gradation of the slip resistance of granite slabs in terms of SRV values was quite well reflected in the acceptance angle values determined by the shod ramp method (Figure 9). It was found that the least resistant to slipping in terms of αob values were PO slabs, which according to [3] should be regarded as out-of-class (αob ≤ 6°), followed by PL of class R10 (10° < αob ≤ 19°) and GR series of class R12 (27° < αob ≤ 35°). The highest antislip properties were exhibited by SZ slabs with αob equal to 34.7°; however, this also places them in class R12. The above classification leads to the conclusion that the resistance of PL series slabs can be considered normal, while SZ and GR series slabs can be considered high (Figure 3), which generally corresponds to the classification according to SRV in dry conditions. However, polished slabs with very low roughness (Ra equal to 1.85 μm) are noteworthy. In the SRV test in dry conditions, they obtained a result of ≥ 36, which translates into a high score of slip resistance according to the criteria of the UK Slip Resistance Group [2]. The result of an αob ≤ 6°, on the other hand, should be considered as disqualifying the solution in the context of floor application.
3.3. Sliding Friction Coefficient
The third method used in this study to verify slip resistance was to measure the dynamic friction coefficient, which was conducted under conditions analogous to those used in the slip resistance test. The results obtained with the rubber slider set (μR) are shown in Figure 10 and those with the leather slider set (μL) are shown in Figure 11. In both cases, the dynamic friction coefficient values were close to the value of slip resistance. The lowest μR and μL values under both dry and wet conditions were obtained for PO slabs at 0.57 and 0.39 and 0.46 and 0.42, respectively, followed by PL slabs at 0.58 and 0.54 and 0.58 and 0.47, respectively. The μR and μL results obtained for brushed and grained slabs were nearly the same level under dry conditions at 0.68 and 0.73 and 0.67 and 0.72, respectively, while the values under wet conditions were 0.66 and 0.60 and 0.67 and 0.59, respectively. Analyzing the obtained μR and μL results in the context of the criteria [25] all tested solutions except for the PO series in the test with rubber sliders can be assigned to the level of 0.40 ≤ μ ≤ 0.74, which means that the slabs showed a satisfactory slip resistance in both in dry and wet conditions (Figure 4).
4. Discussion
The variety of methods for evaluating slip resistance creates the need to address the relationship between test results obtained by different methods and establish links between classification criteria related to these methods. This issue should be based on testing as many flooring materials as possible.
For measurement methods for which the results are metrologically comparable (i.e., relate to the same physical quantity and are metrologically traceable to the same reference), the issue is relatively straightforward: a method compatibility assessment can be applied to determine whether the differences between results of measurements obtained by different methods are insignificant [23,26].In the present case of slip resistance evaluation, the test methods were determined by the test process’s convention, and their results do not refer to the same physical quantity. The compatibility assessment of the methods in such a case is not justified, and other indirect methods should be used to assess the differences in trueness and precision.
A comparison of the acceptance angle values (αob using ramp test), SRV, µR (sliding friction coefficient using rubber slider), and µL (sliding friction coefficient using leather slider) should also take into account the fact that αob tests were carried out on a surface covered with engine oil, while SRV and µ tests were carried out on dry surface and on surface wetted with water. Dry surface and wet surface test results differed but were subject to the same classification. Due to the fact that the ramp test was conducted on four surfaces (PO, PL, SZ, and GR) and the other tests were conducted on the same surfaces but with their number doubled using wet surface and dry surface, we used a method of comparison that did not treat the wet and dry surface as separate surfaces but rather considered the tests for wet surface and dry surface as separate test methods.
Pearson’s correlation coefficient within each pair of results was used to compare the results obtained by the seven methods thus defined. The results are presented in Table 2. These were determined for 80 results in each method. All values were greater than the critical value at the confidence level α = 0.05 [27].
Table 2.
Test Mark | SRV (dry) | SRV (wet) | µR (dry) | µR (wet) | µL (dry) | µL (wet) |
---|---|---|---|---|---|---|
Ramp test | 0.977 | 0.970 | 0.837 * | 0.988 | 0.979 | 0.955 |
SRV (dry) | - | 0.984 | 0.863 * | 0.990 | 0.978 | 0.963 |
SRV (wet) | - | - | 0.783 * | 0.981 | 0.949 | 0.914 * |
µR (dry) | - | - | - | 0.852 * | 0.879 * | 0.904 * |
µR (wet) | - | - | - | - | 0.978 | 0.953 |
µL (dry) | - | - | - | - | - | 0.974 |
If we consider that the results were obtained for four levels (PO, PL, SZ, and GR), the critical value of Pearson’s coefficient for n = 4 is much higher and values marked * are smaller than the critical value, but in nonstatistical evaluation such values are usually considered as good correlation.
The interpretation of the Pearson’s coefficient depends on the purpose and context. For advanced and precise measurement methods, the values shown in the table could be considered insufficient confirmation of the correlation between the results. Each of the methods used in this experiment is characterized by specific arrangements and many noncontrollable factors, namely factors that were not precisely determined in the test model. These factors may cause variabilities taking the form of differences between the results under repeatability and reproducibility conditions.
To compare tests in terms of the dispersion of the results obtained, repeatability standard deviation (sr) and reproducibility standard deviation (sR) according to ISO 5725-2 [28] are used. However, when the results obtained by different methods are not comparable, standardization of the results would have to be used to obtain information about the differences in precision of the methods. However, classical standardization unifies the dispersion of test results to a standard deviation value of 1. Thus, in this case, quotient transformations where the normalizing values are maximal values for each test method were used. This kind of transformation retains the differences in means and standard deviations [27].
The resulting repeatability standard deviations (sr) and reproducibility standard deviation (sR) calculated from the results undergoing quotient transformations are shown in Figure 12.
Analysis of the graph shown in Figure 12 indicates that the ramp test method has fairly good repeatability compared to other methods. It defines the angle at which the examiner researcher stopped feeling confident, so the judgment given by the same researcher (expressed by the value of the angle, αob) was not significantly different for the same substrate surface. When another person conducted the research test, their feelings about safety might have varied somewhat, despite their initial mental and physical state. This was confirmed by statistical analysis of the difference between the variance of reproducibility (sR) and repeatability (sr), which is the component of variance derived from intergroup (interlaboratory) differences:
sL2 = sR2 − sr2 | (2) |
The SRV test had a low standard deviation value of repeatability and reproducibility, and the precision of the method depended very little on the surface on which the test was performed. On the other hand, methods based on the determination of the µ factor showed clear differences in precision depending on the surface tested. Table 3 shows the values of the sL deviation.
Table 3.
Test Mark | sL (PO) | sL (PL) | sL (SZ) | sL (GR) |
---|---|---|---|---|
Ramp test | 0.000 | 0.018 | 0.035 | 0.026 |
SRV (dry) | 0.007 | 0.007 | 0.004 | 0.009 |
SRV (wet) | 0.002 | 0.002 | 0.007 | 0.003 |
µR (dry) | 0.005 | 0.008 | 0.004 | 0.044 |
µR (wet) | 0.017 | 0.003 | 0.001 | 0.027 |
µL (dry) | 0.003 | 0.009 | 0.020 | 0.006 |
µL (wet) | 0.002 | 0.022 | 0.011 | 0.006 |
To determine the statistical significance of differences in the precision of individual methods (ramp test, slip resistance value (for dry and wet surfaces), friction coefficients (µR for dry and wet surfaces and µL for dry and wet surfaces), and differences in the precision of testing of individual surfaces (PO, PL, SZ, and GR)), chi-squared test () was performed for sL2 variances.
The following criterion was used:
(3) |
where n is the number of degrees of freedom, n = N − 1 (N = 20 for each value of sL2). is the variance of the population. As this value is unknown, it was taken as the mean of all sL2 scores. is the critical value for the significance level α = 0.05 and the number of degrees of freedom n.
Thus, the test was used to confirm the hypothesis that the differences of the interlaboratorty component of variance sL2 of the results obtained for different types of surfaces and different types of tests were not statistically significant.
In Table 3, the values of sL for which sL2 had not met the condition described by Equation (3) are marked with gray shading. The greatest number of deviating values of interlaboratory variance was found for two surfaces: SZ and GR. This may mean difficulty in ensuring the reproducibility of the results of tests carried out on such surface. As previously established, the SRV method was characterized by the best (as a set for all surfaces) reproducibility.
The precision of the test method, particularly the interlaboratory variance, is extremely important because poor reproducibility of the method increases the risk of incorrect evaluation. From this point of view, on the basis of the presented results, the SRV method should be considered the best (the lowest risk of different assessment by different laboratories).
On the other hand, to get a complete picture of the slip resistance test method, the classification method assigned to it should also be considered, including the classification resolution.
Different scales of safety risk classifications (Figure 2, Figure 3 and Figure 4) were assigned to the ramp test, slip resistance value, and sliding friction test methods. Figure 13 shows the test results against the classifications assigned to the methods.
The ramp test classification based on acceptance angle values (αob) had the highest resolution. The three surfaces PL, SZ, and GR were assigned to different classes, with the results for PL and SZ surfaces being on the edge of different classes. The PO surface results were below the lower limit of the acceptance angle, indicating an unacceptable risk of slipping.
In the scales assigned to the SRV and sliding friction coefficient tests, PL, SZ, and GR in both wet and dry states as well as the PO floor in dry state were in the same class, i.e., low risk according to the SRV value, while the µR and µL values were in the satisfactory class. Only the wet PO floor in the SRV test results reached the high slip risk class. The µR and µL values were on the borderline between admissible and satisfactory classes.
The designations for individual classifications were as follows: for ramp test (floor classes): L: low (R9), N: normal (R10), G: good (R11), H: high (R12), and V: very high (R13); for SRV (risk of the slip): Lr: low risk, Mr: medium risk, and Hr: high risk; for sliding friction coefficient (floor classes): d: dangerous, a: admissible, s: satisfactory, and m: model.
The above results indicate that the test method and classification method strongly influenced the slip risk assessment. This supports the thesis regarding the need for uniformity of testing and evaluation rules. Various paths may lead to consistency in assessments, all requiring thorough research. This includes assigning a specific test and classification method to the floor usage conditions; using only one method for all slip resistance assessments; and creating a new research method and a new, consistent classification. A transitional phase could be to provide the possibility of converting results and classifications obtained with different methods to harmonized indices, which could allow comparisons of products in terms of slip risk in situations where slip resistance results are obtained using different methods. This paper is an outline of the problem and an embryo of that phase, showing the relationship between the results and classifications for one type of material with differently prepared surfaces. Creating a matrix to compare slip resistance results would have to involve a large number of test results obtained for different flooring materials. The authors intend to continue to work in this direction.
5. Conclusions
This study analyzed the slip resistance of polished, flamed, brushed, and grained granite slabs in terms of slip resistance value, acceptance angle in shod ramp test, and sliding friction coefficients and found that the evaluation of the products in terms of slip resistance was strongly related to the applied testing and classification method.
The test method’s influence was particularly visible with regard to products with very low roughness, such as polished slabs. These solutions were classified as low slip risk for slip resistance value in dry conditions and satisfactory for dynamic friction coefficient. In the ramp test, they obtained an acceptable angle value at a level that prevented them from being classified in the lowest slip resistance class.
The test methods were compared in terms of accuracy and resolution of classification. Neither method had been well assessed on both criteria. The SRV method showed the highest precision, resulting in the lowest risk of different classification by different laboratories, but the resolution of the classification assigned to this method was too low. The ramp test method had a resolving classification, but the test method reproducibility appeared to be the worst.
The choice of test and classification method is often dictated by national regulations related to specific applications. However, a question still remains as to which of the assessment methods provides the lowest risk of slippage. According to the authors of this paper, it is not guaranteed by even the most precise method that classifies all surfaces as providing a low risk of slippage. Thus, the safest of the discussed methods of testing and classification, both from the point of view of producer and user risk, seems to be the ramp test.
The testing and classification results indicate an important need to standardize testing methods and classification methods or to create a matrix that allows comparison of results obtained by different methods.
The authors will continue research on other types of flooring materials.
Acknowledgments
Special thanks to Cezary Strąk and Andrzej Nowacki for technical support.
Author Contributions
Conceptualization, E.S. (Ewa Sudoł); methodology, E.S. (Ewa Sudoł) and E.S. (Ewa Szewczak); formal analysis, E.S. (Ewa Sudoł) and E.S. (Ewa Szewczak); investigation, E.S. (Ewa Sudoł) and E.S. (Ewa Szewczak); resources, E.S. (Ewa Sudoł), E.S. (Ewa Szewczak), and M.M.; writing—original draft preparation, E.S. (Ewa Sudoł), E.S. (Ewa Szewczak), and M.M.; writing—review and editing, E.S. (Ewa Sudoł) and E.S. (Ewa Szewczak); visualization, E.S. (Ewa Sudoł). and E.S. (Ewa Szewczak). All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by Ministerstwo Nauki i Szkolnictwa Wyższego (NZM-059/2020).
Data Availability Statement
The data presented in this study are available on request from the corresponding author.
Conflicts of Interest
The authors declare no conflict of interest.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Regulation (EU) No 305/2011 of the European Parliament and of the Council. [(accessed on 15 January 2021)]; Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv:OJ.L_.2011.088.01.0005.01.ENG&toc=OJ:L:2011:088:TOC.
- 2.The UK Slip Resistance Group Guidelines The Assesment of Floor Slip Resistance. [(accessed on 15 January 2021)]; Available online: www.ukslipresistance.org.uk.
- 3.Deutsches Institut für Normung . DIN 51130:2014 Testing of Floor Coverings-Determination of the Anti-Slip Property-Workrooms and Fields of Activities with Slip Danger-Walking Method-Ramp Test. Deutsches Institut für Normung; Berlin, Germany: 2014. [Google Scholar]
- 4.Bellopede R., Marini P., Karaca Z., Gokce M.V. Relationship between slipperiness and other characteristics of stones used as flooring slabs. J. Mater. Civ. Eng. 2016;28 doi: 10.1061/(ASCE)MT.1943-5533.0001556. [DOI] [Google Scholar]
- 5.Ministerstwa Inwestycji i Rozwoju Standardy Projektowania Budynków dla Osób Niepełnosprawnych. [(accessed on 15 January 2021)]; Available online: https://www.gov.pl/web/rozwoj-praca-technologia/standardy-dostepnosci-budynkow-dla-osob-z-niepelnosprawnosciami.
- 6.Państwowa Inspekcja Pracy: Praktyczne Sposoby Zapobiegania Potknięciom I Poślizgnięciom. [(accessed on 15 January 2021)]; Available online: www.pip.gov.pl.
- 7.Kemmlert K., Lundholm L. Slips, trips and falls in different work groups—With reference to age and from a preventive perspective. Appl. Ergon. 2001;32:149–153. doi: 10.1016/S0003-6870(00)00051-X. [DOI] [PubMed] [Google Scholar]
- 8.Kim I.-J. Investigation of floor surface finishes for optimal slip resistance performance. Saf. Health Work. 2018;9:17–24. doi: 10.1016/j.shaw.2017.05.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Sariisik A. Safety analysis of slipping barefoot on marble covered wet areas. Saf. Sci. 2009;47:1417–1428. doi: 10.1016/j.ssci.2009.03.006. [DOI] [Google Scholar]
- 10.Granit-Strzegom. [(accessed on 15 January 2021)]; Available online: http://granit-strzegom.com.pl/realizacje.
- 11.Health and Safety Executive L24 Workplace Health, Safety and Welfare Workplace (Health, Safety and Welfare) Regulations Approved Code of Practice and Guidance. [(accessed on 15 January 2021)]; Available online: https://www.hse.gov.uk.
- 12.Nemire K., Johnson D.A., Vidal K. The science behind codes and standards for safe walkways: Changes in level, stairways, stair handrails and slip resistance. Appl. Ergon. 2016;52:309–316. doi: 10.1016/j.apergo.2015.07.021. [DOI] [PubMed] [Google Scholar]
- 13.Terjék A., Dudás A. Ceramic Floor Slipperiness Classification—A new approach for assessing slip resistance of ceramic tiles. Constr. Build. Mater. 2018;164:809–819. doi: 10.1016/j.conbuildmat.2017.12.242. [DOI] [Google Scholar]
- 14.Choi S.-K., Kudoh R., Koga J., Mikami T., Yokoyama Y., Takahashi H., Ono H. A comparative evaluation of floor slip resistance test methods. Constr. Build. Mater. 2015;94:737–745. doi: 10.1016/j.conbuildmat.2015.07.152. [DOI] [Google Scholar]
- 15.Li K.W., Chang W.R., Leamon T.B., Chen C.J. Floor slipperiness measurement: Friction coefficient, roughness of floors, and subjective perception under spillage conditions. Saf. Sci. 2004;42 doi: 10.1016/j.ssci.2003.08.006. [DOI] [Google Scholar]
- 16.Çoşkun G. A new slip safety risk scale of natural stones with statistical K-means clustering analysis. Arab. J. Geosci. 2018;11:799. doi: 10.1007/s12517-018-4173-3. [DOI] [Google Scholar]
- 17.International Organization for Standardization ISO . ISO 3274:1996 Geometrical Product Specifications (GPS)—Surface Texture: Profile Method—Nominal Characteristics of Contact (Stylus) Instruments. International Organization for Standardization ISO; Geneva, Switzerland: 1996. [Google Scholar]
- 18.International Organization for Standardization ISO . ISO 4288:1996 Geometrical Product Specifications (GPS)—Surface Texture: Profile Method—Rules and Procedures for The Assessment of Surface Texture. International Organization for Standardization ISO; Geneva, Switzerland: 1996. [Google Scholar]
- 19.European Committee for Standardization CEN . EN 14231:2003 Natural Stone Test Methods-Determination of the Slip Resistance By Means of the Pendulum Tester. European Committee for Standardization CEN; Brussels, Belgium: 2003. [Google Scholar]
- 20.European Committee for Standardization CEN . CEN/TS 16165:2012 Determination of Slip Resistance of Pedestrian Surfaces; Methods of Evaluation. European Committee for Standardization CEN; Brussels, Belgium: 2012. [Google Scholar]
- 21.Chang W.-R., Kim I.-J., Manning D.P., Bunterngchit Y. The role of surface roughness in the measurement of slipperiness. Ergonomics. 2001;44:1200–1216. doi: 10.1080/00140130110085565. [DOI] [PubMed] [Google Scholar]
- 22.Liu J., Guan B., Chen H., Liu K., Xiong R., Xie C. Dynamic model of polished stone value attenuation in coarse aggregate. Materials. 2020;13:1875. doi: 10.3390/ma13081875. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Chen C.C., Chen Z.X., Chang C.L., Lin F.L. The slip-resistance effect evaluation of floor roughness under different liquid viscosity. Procedia Manuf. 2015;3:5007–5013. doi: 10.1016/j.promfg.2015.07.665. [DOI] [Google Scholar]
- 24.Karaca Z., Gürcan S., Gökçe M.V., Sivrikaya O. Assessment of the results of the pendulum friction tester (EN 14231) for natural building stones used as floor-coverings. Constr. Build. Mater. 2013;47:1182–1187. doi: 10.1016/j.conbuildmat.2013.06.011. [DOI] [Google Scholar]
- 25.Deutsches Institut für Normung . DIN 51131:2014 Testing of Floor Coverings-Determination of the Anti-slip Property-Method for Measurement of the Sliding Friction Coefficient. Deutsches Institut für Normung; Berlin, Germany: 2014. [Google Scholar]
- 26.Szewczak E., Winkler-Skalna A., Czarnecki L. Sustainable test methods for construction materials and elements. Materials. 2020;13:606. doi: 10.3390/ma13030606. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Statistics Solutions. [(accessed on 15 January 2021)]; Available online: https://www.statisticssolutions.com/table-of-critical-values-pearson-correlation.
- 28.International Organization for Standardization ISO . ISO 5725-2:1994 Accuracy (Trueness and Precision) of Measurement Methods and Results: Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method. International Organization for Standardization ISO; Geneva, Switzerland: 1994. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data presented in this study are available on request from the corresponding author.