Abstract
BACKGROUND AND PURPOSE:
The present study follows an experimental work based on the characterization of the biomechanical behavior of the aneurysmal wall and a numerical study where a significant difference in term of volume variation between ruptured and unruptured aneurysm was observed in a specific case. Our study was designed to highlight by means of numeric simulations the correlation between aneurysm sac pulsatility and the risk of rupture through the mechanical properties of the wall.
MATERIALS AND METHODS:
In accordance with previous work suggesting a correlation between the risk of rupture and the material properties of cerebral aneurysms, 12 fluid-structure interaction computations were performed on 12 “patient-specific” cases, corresponding to typical shapes and locations of cerebral aneurysms. The variations of the aneurysmal volume during the cardiac cycle (ΔV) are compared by using wall material characteristics of either degraded or nondegraded tissues.
RESULTS:
Aneurysms were located on 6 different arteries: middle cerebral artery (4), anterior cerebral artery (3), internal carotid artery (1), vertebral artery (1), ophthalmic artery (1), and basilar artery (1). Aneurysms presented different shapes (uniform or multilobulated) and diastolic volumes (from 18 to 392 mm3). The pulsatility (ΔV/V) was significantly larger for a soft aneurysmal material (average of 26%) than for a stiff material (average of 4%). The difference between ΔV, for each condition, was statistically significant: P = .005.
CONCLUSIONS:
The difference in aneurysmal pulsatility as highlighted in this work might be a relevant patient-specific predictor of aneurysm risk of rupture.
Intracranial aneurysms kill about 15,000 people in Europe each year. Most are young, between 40 and 60 years old. New medical imaging techniques are now able to clearly depict intracranial aneurysm, but no systematic screening of this disease exists at the moment. The main reason is that 2%–6% of the general population lives with an aneurysm,1 but only 0.5% of these will rupture. Screening for intracranial aneurysm is not justified unless it is capable of detecting vulnerable aneurysms. Subarachnoid hemorrhage is the consequence of aneurysm rupture and approximately 12% of patients with SAH die before receiving medical attention, 40% of patients will die within the first month, and 30% will present with a severe permanent disability. Nevertheless, with brain imaging being more frequently and widely used, a growing number of intracranial aneurysms are being diagnosed, introducing the question of which aneurysms harbor a sufficiently high risk of rupture to merit a prophylactic repair. This question remains unsolved at the moment and the therapeutic decision for an unruptured aneurysm is still a challenging point discussed by the neurosurgeon/neurointerventionist based on sparse epidemiologic clinical data that cannot represent the specific individual risk of the patient.
Recent publications have addressed this issue and have demonstrated that, among other variables affecting the natural history of aneurysms, size and location represent independent predictors of both risk of rupture and surgical/endovascular repair outcomes.2,3 Other parameters, such as irregular aneurysm shape and the presence of blebs are recognized as markers of weak wall structure and high risk of rupture. Rapid aneurysm growth is also likely a risk factor for rupture.4
From a mechanical point of view, the rupture of an aneurysm occurs when wall tension exceeds the strength of the wall tissue. Because these quantities cannot be assessed via conventional medical imaging, a natural approach is to compute the wall tension and set a rupture threshold.
Few studies consider the coupled fluid-structure interaction (FSI) problem, where the flow equations for blood are solved together with the structural equations for the tissue.5 The problem is the lack of data on mechanical properties of cerebral arteries and aneurysms; most of the studies based on an FSI6–10 framework do not use experimental mechanical behavior of the aneurysm wall as input. A few exceptions exist for abdominal aorta aneurysms11,12 but not for intracranial aneurysms until recently when, in a study by Costalat et al,13 the aneurysm wall properties were characterized and a classification of aneurysm wall behavior was carried out. One of the main conclusions of this work was that the clinical status of the aneurysm (unruptured, preruptured, and ruptured) was strongly correlated with the mechanical behavior of the aneurysm wall and, hence, a classification was proposed (stiff, intermediate, and soft).
This was followed with FSI computations by Sanchez et al,14 who demonstrated for 1 specific aneurysm that the different mechanical properties of the aneurysm wall (stiff or soft) are responsible for significantly different variations in aneurysm volume over the cardiac cycle (pulsatility). A parametric study was also achieved in this work and demonstrated that uncertainties did not change the main conclusion.
The further application of these results to the in vivo setting and in particular to cerebral aneurysms arising from the circle of Willis is an additional important step.
The aim of this work was to investigate and verify the correlation between wall biomechanical properties (stiff and soft) and aneurysmal volume variation during the cardiac cycle for a variety of aneurysms that differ in shape and location in the circle of Willis.
This study was conceived and carried out as part of the Individual Risk of Rupture Assessment consortium, which is a research project dedicated to the evaluation of patient-specific risk of rupture of cerebral aneurysms. The consortium brings together neurosurgeons, neuroradiologists, and researchers in biomechanical engineering in a common translational research project.
Materials and Methods
Identification of Mechanical Behavior of Aneurysm Wall
The details of the study establishing the correlation between the aneurysm status and tissue mechanical properties are given in the work of Costalat et al.13 The methodology and main results are briefly given for the sake of completeness. A similar study was conducted by Duprey et al15 for thoracic aortic aneurysms.
Each sample was studied as appropriate for biomaterials.16–19 Only the meridional axis of the aneurysm was chosen to preserve maximum length of the aneurysmal tissue in the sample, given the very small size of each specimen and the fragility of the tissue. Using these measurement series, a model of the tissue behavior was proposed for large displacements to represent the evolution of the stress in the materials.20 For this purpose, the assumption that the material is isotropic and noncompressible was made and the hyperelastic model of Mooney-Rivlin with 3 parameters was selected.1 It reads:
where W is the strain energy potential, I1 = tr(C) and I2 = (tr2(C) – tr(C2)) are the first and second strain invariants of the right Cauchy-Green deformation tensor C, and C10, C01, and C11 are the material coefficients.
All unruptured aneurysms presented as stiffer tissue than the ruptured aneurysms.
Their mechanical behavior was either stiff or intermediate. Conversely, all ruptured aneurysms correspond to a soft tissue. The corresponding parameters are given in Table 1 while the strain/stress curves are displayed in Fig 1.
Table 1:
Aneurysm | C10 (MPa) | C01 (MPa) | C11 (MPa) |
---|---|---|---|
Soft | 0.024 | 0.026 | 0.42 |
Stiff | 0.39 | 0 | 22.14 |
Numeric Method
Aneurysmal Geometry.
Aneurysm geometry was obtained from 3D rotational angiography. Using dedicated software ScanIP (Simpleware, Exeter, United Kingdom), the aneurysmal geometries were cleaned up by keeping only the aneurysms and the parent vessels to reduce the region of interest. A low-pass filter was applied on the geometries to reduce noise-to-signal ratio. The results were exported as stereolithography files to proceed to numeric analysis.
Simulation Parameters.
The flow boundary conditions imposed were obtained from specific patient examinations by using phase-contrast MR imaging for each aneurysm location (3T Skyra; Siemens, Erlangen, Germany). The velocity profiles were considered as uniform. Outlet pressure was computed by computational fluid dynamics and used as boundary conditions at the outlet of the computational domain. The pressure was obtained by resolving the 1D equations in the arterial network with boundary flow conditions from the imaging measurement.21
An intracranial pressure of 20 mm Hg22 was applied on the external surface of the geometries to recreate the in vivo conditions.
Physical Modeling.
The blood flow within the computational domain is described by the incompressible Navier-Stokes equations (2) and (3)
where vf is the time dependent flow velocity vector, ρf is the attenuation of blood, and σf is the stress tensor for the fluid part. The flow is assumed to be laminar, a reasonable assumption given the moderate value of the Reynolds number (Re ≈ 300). Blood is modeled as a Newtonian fluid,4 of attenuation of ρf = 1050 kg/m3 and dynamic viscosity of μ = 0.004 Pa × s.9,23–25
where p is the pressure, I is the identity tensor, and D is the rate of deformation tensor.
For the parent artery, a linear elastic model was selected to focus the attention on the aneurysmal sac and to reduce the computational time. The structural equation solved for both the artery and aneurysmal sac reads5:
where σs is the Cauchy strain for the structural part and vs stands for the structural velocity vector.
The aneurysm wall is modeled as an isotropic incompressible hyperelastic material6:
where F is the transformation gradiant tensor, E is the Green Lagrangian strain tensor, and W is the strain energy potential defined in Eq. (1).
The material used for the parent artery has the following properties: Young modulus E = 3 MPa, Poisson ratio ν = 0.49, specific mass ρs = 2300 kg/m3, and thickness epa = 0.6 mm.24,26 The thickness of the aneurysm wall is e = 0.38 mm. A linear model was used for the arterial wall because the deformations are small enough in all cases (<5%) to stay in the small deformation theory.
Furthermore, the edge nodes of the arterial extremities are taken away from the displacement in the longitudinal direction.
FSI Computations.
Computations were performed by using Workench version 13 (ANSYS, Canonsburg, Pennsylvania). The fluid motion equations were solved with the software CFX, which uses the finite volume approach and the Newton-Raphson method for solving the subsequent nonlinear system. For the structural part, Mechanical software employed the finite-element method and the Newton-Raphson algorithm. The wall pressure resulting from the fluid was imported as boundary conditions in the structural analysis while wall displacement calculated by the structure solver was imported as a boundary condition for the fluid solver; this procedure was carried out in an iterative manner within each time-step. It was an iterative implicit coupling. At the interface of the 2 physical domains, the element type differs and the nodes of the 2 meshes did not coincide, so surface interpolation was carried out.27 For each FSI computation, a time-step of 0.004 seconds was used. The structural meshes were composed by 2500 to 5000 shell elements and the fluid meshes by 100,000 to 300,000 tetrahedral elements. These meshes were fine enough to ensure the convergence of the computations. The 2 FSI computations of the reference case from Sanchez et al14 were performed for mesh refinements multiplied by 10 (about 30,000 elements for structural mesh and 1,000,000 elements for fluid mesh). Despite a significant increase of the computation time, the results were similar. For example, in the soft case, the maximal mesh displacement was 0.78 instead of 0.77 mm (variation of 1.3%) and the volume variation was 44.3 mm3 instead of 44 mm3 (variation of 0.7%).
A structural computation was performed before the FSI computation to determine the stress state of the acquired geometry. All the details about the initial stress of the aneurysm geometry are given in Sanchez et al.14
Wall Motion Analysis.
For each aneurysmal geometry, 2 FSI computations were performed by using the 2 different biomechanical properties (stiff and soft) defined in the Identification of Mechanical Behavior of Aneurysm Wall section. Volume variations and wall motions were calculated for each aneurysm. For each case, the systolo-diastolic variation of the volume of the aneurysm (ΔV) was computed from the results. The maximal mesh displacement on the aneurysm sac Dmax was also calculated. ΔV represents global information about the aneurysmal sac behavior whereas Dmax provides local information (maximal displacement of a point of the aneurysm boundary).
To compare ΔV and Dmax between soft and stiff material for different aneurysms, we defined the following ratio:
A pulsatility index was also defined as: Pulsatility = ΔV/V, where V is the diastolic volume of the aneurysmal sac.
Statistical Analysis
A statistical analysis was performed to evaluate the influence of ΔV and Dmax in soft and stiff cases. The comparison was made by using a nonparametric Wilcoxon rank test for continuous variables and a Fisher exact test for categoric ones. Statistical significance threshold was set at 5%. Statistical analyses were performed by using SAS version 9.1 (SAS Institute, Cary, North Carolina).
Results
Aneurysm Population
Twelve aneurysms from 12 different patients were computed with the stiff and the soft materials. These aneurysms were located on 7 different arteries: left and right middle cerebral arteries (4 cases), anterior cerebral artery (3 cases), ICA (1 case), vertebral artery (1 case), ophthalmic artery (1 case), and basilar artery (2 cases). These had a variety of shapes: simple (uniform) or complex (multilobulated). The volume varied from 18 mm3 to 392 mm3. Geometric information is displayed in Table 2.
Table 2:
Aneurysm | Location | V (mm3) | Shape | D (mm) | N (mm) | D/N |
---|---|---|---|---|---|---|
1 | MCA R | 61 | Simple | 4.8 | 4 | 1.2 |
2 | MCA L | 51 | Complex | 3.4 | 3.75 | 0.91 |
3 | ACA | 161 | Simple | 5.25 | 5.6 | 0.94 |
4 | MCA R | 188 | Complex | 5.5 | 6.5 | 0.85 |
5 | ICA | 392 | Complex | 9.2 | 5 | 1.84 |
6 | VA | 45 | Simple | 4 | 2.3 | 1.74 |
7 | MCA L | 212 | Complex | 7.8 | 6.6 | 1.18 |
8 | ACA | 232 | Complex | 8 | 4.5 | 1.78 |
9 | ACA | 79 | Complex | 6.85 | 2.9 | 2.36 |
10 | OA | 138 | Simple | 6.1 | 4.3 | 1.41 |
11 | BA | 68 | Complex | 4.4 | 3.9 | 1.13 |
12 | BA | 18 | Simple | 3 | 3 | 1 |
Note:—V indicates diastolic volume; D, the dome size; N, the neck size; D/N, the ratio of dome/neck; ACA, anterior cerebral artery; VA, vertebral artery; OA, ophthalmic artery; BA, basilar artery; R, right; L, left.
Wall Motion Results
Figure 2 gives an example of the FSI results for 3 different cases by displaying maximum displacement for the simulations with soft or stiff materials. All results of the patient-specific FSI computations are displayed in Tables 3 and 4. Two aneurysms (5 and 6) show unusual results. For aneurysm 5, the volume variation is 149 mm3. The important initial volume of the aneurysm sac, almost 400 mm3, can explain this important variation. This aneurysm could be considered as a giant aneurysm. Nevertheless, the pulsatility ratio is still in the range of 30% in comparison to an overall mean of 25% for the cases. For aneurysm 6, the pulsatility is much more important than in the other cases. That is the result of a volumetric flow rate more important in this location (vertebral artery) for this specific patient compared with the others (Table 4); this due to the particularity of this cerebral arterial network.
Table 3:
Aneurysm | Material | V (mm3) | ΔV (mm3) | Pulsatility = ΔV/V (%) | >Dmax (mm) |
---|---|---|---|---|---|
1 | Soft | 61 | 10 | 16 | 0.35 |
Stiff | 1 | 2 | 0.12 | ||
2 | Soft | 51 | 8 | 16 | 0.32 |
Stiff | 0.5 | 1 | 0.09 | ||
3 | Soft | 161 | 44 | 27 | 0.7 |
Stiff | 6 | 4 | 0.26 | ||
4 | Soft | 188 | 37 | 20 | 0.71 |
Stiff | 7 | 4 | 0.15 | ||
5 | Soft | 392 | 149 | 38 | 1 |
Stiff | 18 | 5 | 0.45 | ||
6 | Soft | 45 | 33 | 73 | 1.8 |
Stiff | 4 | 9 | 1.2 | ||
7 | Soft | 212 | 60 | 28 | 1.05 |
Stiff | 14 | 7 | 0.48 | ||
8 | Soft | 232 | 54 | 23 | 0.84 |
Stiff | 10 | 4 | 0.4 | ||
9 | Soft | 79 | 15 | 19 | 0.48 |
Stiff | 3 | 4 | 0.15 | ||
10 | Soft | 138 | 26 | 19 | 0.47 |
Stiff | 5 | 4 | 0.17 | ||
11 | Soft | 68 | 11 | 16 | 0.42 |
Stiff | 2.5 | 4 | 0.12 | ||
12 | Soft | 18 | 4 | 22 | 0.27 |
Stiff | 0.5 | 3 | 0.14 |
Table 4:
Aneurysm | Systole Flow Rate (m3·s−1) | Flow Rate Variation (m3·s−1) | ΔV (mm3) |
---|---|---|---|
1 | 3.21 × 10−06 | 1.78 × 10−06 | 10 |
2 | 3.10 × 10−06 | 1.75 × 10−06 | 8 |
3 | 2.85 × 10−06 | 1.95 × 10−06 | 44 |
4 | 3.36 × 10−06 | 1.84 × 10−06 | 37 |
5 | 4.21 × 10−06 | 2.15 × 10−06 | 149 |
6 | 3.55 × 10−06 | 4.454 × 10−05 | 33 |
7 | 3.12 × 10−06 | 1.77 × 10−06 | 60 |
8 | 1.28 × 10−06 | 1.27 × 10−06 | 54 |
9 | 1.62 × 10−06 | 7.94 × 10−07 | 15 |
10 | 2.92 × 10−07 | 1.36 × 10−06 | 26 |
11 | 5.07 × 10−06 | 3.34 × 10−06 | 11 |
12 | 5.07 × 10−06 | 3.34 × 10−06 | 4 |
A significant difference was observable between ΔV for a stiff material and for a soft material (P = .005). Consequently, the pulsatility index (ΔV /V) was obviously more important for a soft aneurysmal sac (average of 26%) than for a stiff aneurysmal sac (average of 4%), despite the relatively small number of aneurysms considered.
Naturally, we found the same difference for the ratio Rv: Rv varies from 4 (aneurysm 7 and 10) to 16 (aneurysm 2) for an average of 7. Rd also showed differences between stiff and soft materials but to a lesser extent: the minimum was 1.5 (aneurysm 6) and the maximum was 5 (aneurysm 4) and the average was 3 (Table 5). The difference between ΔV and Dmax for each condition was statistically significant: P = .005 for ΔV and P = .02 for Dmax.
Table 5:
Aneurysm | Volume (mm3) | Rv = ΔVsoft/ΔVstiff | Rd = Dmaxsoft/Dmaxstiff |
---|---|---|---|
1 | 61 | 10 | 2.9 |
2 | 51 | 16 | 3.5 |
3 | 161 | 7.3 | 2.7 |
4 | 188 | 5.3 | 4.7 |
5 | 392 | 8.3 | 2.2 |
6 | 45 | 8.25 | 1.5 |
7 | 212 | 4.3 | 2.2 |
8 | 232 | 5.4 | 2.1 |
9 | 79 | 5 | 3.2 |
10 | 138 | 5.2 | 2.8 |
11 | 68 | 4.4 | 3.5 |
12 | 18 | 8 | 1.9 |
Discussion
Our results clearly suggest that the wall displacement provides information about the level of degradation of the aneurysm wall and, thanks to the findings of Costalat et al,13 about the rupture risk of the aneurysm sac. Our study shows that whatever the location of the aneurysm on the circle of Willis, the aneurysmal pulsatility was about 7 times higher for soft/ruptured aneurysms in comparison with stiff/unruptured aneurysms (26% versus 4%). That is the result of a volumetric flow rate more important in this location (vertebral artery) compared with the others (Table 4). These observations are consistent with our previous work (the study from Sanchez et al,14 using FSI computations) where a significant difference between the displacements and volume variations corresponding to the soft (close to the rupture) and stiff (undegraded) tissues was observed in a particular case. This result is generalized to the entirety of the circle of Willis in this paper.
Interestingly, in an observational study on 51 patients, Hayakawa et al,28 using 4D CT angiography, highlighted that the pulsation of the aneurysm sac (or volume variation) between ruptured aneurysms and unruptured aneurysms was significantly different. In their study, 12/51 cerebral aneurysms were ruptured. Among these 12 ruptured cerebral aneurysms, a pulsation was observed in 9 cases (75%). Thirty-nine cerebral aneurysms were unruptured; among these 39 unruptured cerebral aneurysms, a pulsation was observed in 12 cases (30%). Two of these 12 pulsating unruptured cerebral aneurysms were treated by surgery because of the clinical background of the patients. They came to the conclusion that the detection of pulsation in an unruptured aneurysm could therefore be a clue of an important risk factor. Our results confirm this point of view.
Furthermore, the precision needed to identify the aneurysmal wall motion variation between unruptured/ruptured aneurysm would be about 0.1 mm (Dmax) or 0.5 mm3 (ΔV) according to our study. New imaging techniques may approach this high resolution level in recent literature (for example Ishida et al29 and Zhang et al30).
To date, the most relevant solution has been proposed by Karmonik et al31 who used 2D phase contrast MR imaging (1.5T MR imaging) to observe wall displacement over the cardiac cycle on 7 patients (7 aneurysms) and 3 different locations (anterior communicating artery, basilar artery, and ICA). This noninvasive technique was accurate enough to measure wall displacements as small as 0.04 mm, in the range of the expected wall displacement reported in our study. New generation MR imaging at 3T could offer a more accurate depiction of the wall motion in the next future.
As already stated, Dmax gives local information about the wall displacement and in some cases, this parameter is not accurate enough to clearly demonstrate a difference between degraded/ruptured and nondegraded/unruptured aneurysms. The variation of the maximal mesh displacement measured by the software depends strongly on the displacement of the artery. The deformation of the artery induces an additional displacement of the mesh of the aneurysmal sac. Then, the bulge of the artery is added to the displacement of the sac in relation to the artery to obtain the total maximal mesh displacement.
As shown in Table 4, the value of the ratio Rv is more important than Rd and allows us to better characterize aneurysm status. Furthermore, ΔV is a global indicator and is less sensitive to the uncertainties of the input parameters of the computations.14 ΔV is thus thought to be a better parameter to evaluate the risk of rupture.
A limitation of this study was the simplification of the aneurysmal environment in the FSI computations, by assuming that the aneurysm lies in a fluid of a given pressure. This environment would probably influence the geometric variations of the aneurysm depending on the location; friction and contact of the wall with other structures (bone, meninges, arachnoid trabeculae, cerebrospiral fluid) will certainly impact the wall motion.32,33 The assumptions made regarding the aneurysm wall are another limitation. In the present study, the aneurysm wall was considered as isotropic and homogeneous, but the anisotropy of this kind of biologic material is well known.34 Nevertheless, isotropy and homogeneity were assumed because they most probably do not change the trends observed when comparing soft and stiff materials in this range of physiologic solicitation. To characterize the behavior of blood, more sophisticated models can be used to account for non-Newtonian effects, especially in the aneurysmal sac (Cebral et al35 and Sforza et al36). However, these effects are expected to be prevalent only when dealing with local quantities like wall shear stress. This is not the case in the present study where the aneurysmal volume, which is primarily influenced by the pressure forces generated by the blood flow, was analyzed.
Numerous parameters are not known precisely when computing the FSI problem for a specific patient: wall thickness, fluid boundary conditions, artery properties, and intracranial pressure.
Despite these last limitations, the parametric study achieved in previous work14 showed a positive consistency with our results regarding the numerous sources of uncertainty involved in such FSI computations. Therefore, the uncertainties of the input parameters did not change the main conclusion: whatever the values of the parameters (in a range of physiologic variations), the soft/ruptured aneurysms deform more than the stiff/unruptured ones.
CONCLUSIONS
The difference in aneurysmal pulsatility as highlighted in this work might be a relevant patient-specific predictor of aneurysm rupture. These results are consistent with recent observational data in the literature to date. Development of a new imaging technique in the near future would allow for the accurate measurement of wall motion and therefore characterize the intracranial aneurysm vulnerability for any given patient.
Acknowledgments
The authors thank Philips Healthcare Inc for the financial support and ANSYS Inc for their technical support. The authors are also grateful to Simpleware Inc. for providing the software Scan IP and for their technical support. The authors also thank the labex NUMEV for the financial support.
ABBREVIATION:
- FSI
fluid-structure interaction
Footnotes
Disclosures: Simon Mendez—UNRELATED: Grants/Grants Pending: French National Agency for Research,* OSEO,* Comments: Grants from French institution for Simulation of Flows with Red Blood Cells (unrelated to the present work). Jean-Paul Lejeune—UNRELATED: Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: B. Braun Company, Comments: Travel and accommodations expenses related to congresses and meetings of neurosurgery in France. Vincent Costalat—UNRELATED: Consultancy: ev3, Codman, Stryker, Balt; Payment for Lectures (including service on speakers bureaus): Stryker, Balt; Payment for Development of Educational Presentations: Covidien; Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: Stryker, Codman, Balt, MicroVention. *money paid to institution.
REFERENCES
- 1. Wardlaw J, White P. The detection and management of unruptured intracranial aneurysms. Brain 2000;123:205–21 [DOI] [PubMed] [Google Scholar]
- 2. Horikoshi T, Sugita M, Yagishita T, et al. Size of cerebral aneurysms and related factors in patients with subarachnoid hemorrhage. Surg Neurol 2002;61:239–45 [DOI] [PubMed] [Google Scholar]
- 3. Nahed B, Diluna M, Morgan T, et al. Hypertension, age, and location predict rupture of small intracranial aneurysms. Neurosurgery 2005;57:676–83 [PubMed] [Google Scholar]
- 4. Matsubara S, Hadeishir H, Suzukil A, et al. Incidence and risk factors for the growth of unruptured cerebral aneurysms: observation using serial computerized tomography angiography. J Neurosurg 2004;101:908–14 [DOI] [PubMed] [Google Scholar]
- 5. Chung S, Vafai K. A coupling model for macromolecule transport in a stenosed arterial wall. Int J Heat Mass Transfer 2012;45:371–81 [Google Scholar]
- 6. Nicoud F, Moreno R, Tayllamin B, et al. Computational hemodynamics in moving geometries without solving the fluid-structure interaction problem. Paper presented at: Conference on Modelling Fluid Flow 2009. The 14th International Conference on Fluid Flow Technologies. Budapest, Hungary. September 9–12, 2009 [Google Scholar]
- 7. Balocco S, Camara O, Vivas E, et al. Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo. Med Phys 2010;37:1689–706 [DOI] [PubMed] [Google Scholar]
- 8. Rissland P, Alemu Y, Einav S, et al. Abdominal aortic aneurysm risk of rupture: patient-specific FSI simulations using anisotropic model. J Biomech Eng 2009;131:031001 [DOI] [PubMed] [Google Scholar]
- 9. Torii R, Oshima M, Kobayashi T, et al. Fluid structure interaction modeling of a patient-specific cerebral aneurysm: influence of structural modeling. Comput Mech 2008;43:151–59 [Google Scholar]
- 10. Vito R, Hickey J. The mechanical-properties of soft-tissues. 2. The elastic response of arterial segments. J Biomech 1980;13:951–57 [DOI] [PubMed] [Google Scholar]
- 11. Vande Geest J, Schmidt E, Sacks M, et al. The effects of anisotropy on the stress analyses of patient-specific abdominal aortic aneurysms. Ann Biomed Eng 2008;36:921–32 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Vande Geest J, Sacks M, Vorp D. The effects of aneurysm on the biaxial mechanical behavior of human abdominal aorta. J Biomech 2006;39:1324–34 [DOI] [PubMed] [Google Scholar]
- 13. Costalat V, Sanchez M, Ambard D, et al. Biomechanical wall properties of human intracranial aneurysms resected following surgical clipping. J Biomech 2011;44:2685–91 [DOI] [PubMed] [Google Scholar]
- 14. Sanchez M, Ambard D, Costalat V, et al. Biomechanical assessment of the individual risk of rupture of cerebral aneurysms: a proof of concept. Ann Biomed Eng 2013;41:28–40 [DOI] [PubMed] [Google Scholar]
- 15. Duprey A, Khanafer K, Sclicht M. In vitro characterisation of physiological and maximum elastic modulus of ascending thoracic aortic aneurysms using uniaxial tensile testing. Eur J Vasc Endovasc Surg 2010;39:700–07 [DOI] [PubMed] [Google Scholar]
- 16. Ambard D, Cherblanc F. Mechanical behavior of annulus fibrosus: a microstructural model of fibers reorientation. Ann Biomed Eng 2009;37:2256–65 [DOI] [PubMed] [Google Scholar]
- 17. Jourdan F, Samida A. An implicit numerical method for wear modeling applied to hip joint prothesis problem. Comput Methods Appl Mech Eng 2009;198:2209–17 [Google Scholar]
- 18. Malachanne E, Dureisseix D, Jourdan F. Numerical model of bone remodeling sensitive to loading frequency through a poroelastic behavior and internal fluid movements. J Mech Behav Biomed Mater 2011;4:849–57 [DOI] [PubMed] [Google Scholar]
- 19. Swider P, Pedrono A, Ambard D, et al. Substructuring and poroelastic modelling of the intervertebral disc. J Biomech 2010;47:1287–91 [DOI] [PubMed] [Google Scholar]
- 20. Hoi Y, Meng H, Woodward S, et al. Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study. J Neurosurg 2004;101:676–81 [DOI] [PubMed] [Google Scholar]
- 21. Van de Vosse FN. Pulse wave propagation in the arterial tree. Ann Rev Fluid Mech 2011;43:467–99 [Google Scholar]
- 22. Steiner L, Andrews J. Monitoring the injured brain: ICP and CBF. Br J Anaesth 2006;97:26–38 [DOI] [PubMed] [Google Scholar]
- 23. Ai L, Vafai K. A coupling model for macromolecule transport in a stenosed arterial wall. Int J Heat Mass Transfer 2006;49:1568–91 [Google Scholar]
- 24. Watton P, Raberger N, Holzapfel G, et al. Blood flow dynamics and fluid-structure interaction in patient specific bifurcating cerebral aneurysm. J Biomech Eng 2009;131:1–14 [Google Scholar]
- 25. Yang N, Vafai K. Modeling of low-density lipoprotein (LDL) transport in the artery-effects of hypertension. Int J Heat Mass Transfer 2006;49:850–67 [Google Scholar]
- 26. Valencia A, Ledermann D, Rivera R, et al. Blood flow dynamics and fluid-structure interaction in patient specific bifurcating cerebral aneurysm. Int J Numer Methods Fluids 2009;58:1081–1100 [Google Scholar]
- 27. Alnaes M, Isaksen J, Mardal K, et al. Computation of hemodynamics in the circle of Willis. Stroke 2007;38:2500–05 [DOI] [PubMed] [Google Scholar]
- 28. Hayakawa M, Maeda S, Sadato A, et al. Detection of pulsation in ruptured and unruptured cerebral aneurysms by electrocardiographically gated 3-dimensional computed tomographic angiography with a 320- row area detector computed tomography and evaluation of its clinical usefulness. Neurosurgery 2011;69:843–51 [DOI] [PubMed] [Google Scholar]
- 29. Ishida F, Ogawa H, Simizu T, et al. Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography. Neurosurgery 2005;57:460–71 [DOI] [PubMed] [Google Scholar]
- 30. Zhang C, Villa-Uriol M, Craene M, et al. Morphodynamic analysis of cerebral aneurysm pulsation from time-resolved rotational angiography. Med Imag 2009;28:1105–16 [DOI] [PubMed] [Google Scholar]
- 31. Karmonik C, Diaz O, Grossman R, et al. In vivo quantification of wall motion in cerebral aneurysm from 2D cine phase contrast magnetic resonance images. Rofo 2010;182:140–51 [DOI] [PubMed] [Google Scholar]
- 32. San Millan Ruiz D, Yilmaz H, Dehdashti A, et al. The perianeurysmal environment: influence on saccular aneurysm shape and rupture. AJNR Am J Neuroradiol 2006;27:504–12 [PMC free article] [PubMed] [Google Scholar]
- 33. Seshaiyer P, Humphrey J. On the potentially protective role of contact constraints on saccular aneurysms. J Biomech 2001;34:607–12 [DOI] [PubMed] [Google Scholar]
- 34. MacDonald D, Finlay H, Canham P. Directional wall strength in saccular brain aneurysms from polarized light microscopy. Ann Biomed Eng 2000;28:533–42 [DOI] [PubMed] [Google Scholar]
- 35. Cebral J, Castro M, Putman C, et al. Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity. IEEE Trans Med Imag 2005;24:457–67 [DOI] [PubMed] [Google Scholar]
- 36. Sforza D, Putman C, Cebral J. Hemodynamics of cerebral aneurysms. Ann Rev Fluid Mech 2008;41:91–107 [DOI] [PMC free article] [PubMed] [Google Scholar]