Skip to main content
Springer logoLink to Springer
. 2020 May 16;25(1):251–255. doi: 10.1007/s11325-020-02099-w

The effect of in-lab polysomnography and home sleep polygraphy on sleep position

Wojciech Kukwa 1,, Ewa Migacz 1, Tomasz Lis 2, Stacey L Ishman 3,4,5
PMCID: PMC7987683  PMID: 32418018

Abstract

Purpose

Little is known regarding the influence of in-laboratory polysomnography (PSG) equipment on sleep position, especially on the prevalence of supine positioning, which in many cases may lead to a more severe sleep apnea diagnosis. The aim of this study was to assess the percentage of supine sleep during an in-laboratory PSG compared to that seen during a home sleep apnea test (HSAT).

Methods

This was a retrospective cohort study comparing in-laboratory PSG and HSAT using a peripheral arterial tone (PAT) technology device.

Results

Of 445 PSG and 416 HSAT studies analyzed, there was no significant difference in the proportion of supine sleep time between PSG (44%) and HSAT (45%, p = 0.53). Analysis of the differences in sleep position (supine versus non-supine), analyzed by sex, BMI (≥ 30 kg/m2 versus < 30 kg/m2), and age (≥ 60 years versus < 60 years), was significant only for women, who had more supine sleep during HSAT at 61 ± 24% than during PSG at 45 ± 26% (p < 0.001).

Conclusion

Overall there was no difference in the percentage of supine sleep when comparing in-laboratory PSG to HSAT. However, women had more supine sleep with HSAT than with PSG.

Keywords: Obstructive sleep apnea, Sleep position, Positional sleep apnea, Polysomnography, Home sleep apnea test, Sleep study

Introduction

Polysomnography (PSG) is the widely accepted gold standard to diagnose obstructive sleep apnea [1] in both children and adults [24]. It is a comprehensive sleep evaluation based on numerous physiologic parameters, including oxygen saturation, brain electroencephalographic activity, eye movements, muscle activity, heart rate and rhythm, and respiratory function. Measurement of these parameters is carried out using monitors including surface electrodes attached to a PSG headbox, which typically is placed on the patient’s chest. When undergoing PSG, patients spend a night in a sleep laboratory while continuously supervised by a sleep technician.

The origins of PSG date back to the 1950s, when scientists started performing full-night recordings of physiological signals during sleep. Beginning in the early 1960s, sleep researchers started to apply this technology to study sleep pathology [5]. Although PSG is the gold standard for the diagnosis of OSA, it has many limitations including high cost, limited availability, and performance in an artificial sleep setting in the sleep laboratory [6]. Additionally, as demonstrated in 1985 by Cartwright et al., some patients report feeling constrained during in-laboratory PSG due to the presence of numerous leads and monitors resulting in them spending more time in the supine position than they would have during a typical night at home [7]. In light of the fact that OSA is often more severe in the supine position, the assessment for OSA in the sleep laboratory may be misleading and lead to overdiagnosis of patients with positional OSA which can result in inappropriate therapy. A 1996 study by Metersky et al. (n = 12) measured the amount of supine sleep during an in-laboratory nighttime PSG and compared it to an in-laboratory night without any sleep study equipment attached to the patients [8]. This author found that the mean percentage of supine sleep was 49% in the sleep lab which was 56% greater than was seen during the non-PSG night.

In light of these findings and the fact that there are no large studies that analyze the potential effect of the in-laboratory PSG setup on sleep position, the aim of this study was to retrospectively assess the rate of supine sleep during a traditional in-laboratory PSG and to compare it to the rate of supine sleep seen during a home sleep apnea test (HSAT).

Methods

Participants

This was a retrospective cohort study from January 2015 to June 2018 that included consecutive sleep studies for adult patients who underwent in-laboratory PSG or HSAT using PAT technology devices. The inclusion criteria specified patients 18 years or older with a clinical suspicion of OSA who did not have any previous history of treatment for OSA. We excluded patients with a PSG-measured total sleep time (TST) or a PAT-measured true sleep time (pTST) of less than 300 min.

Polysomnography

The in-laboratory PSG was conducted using a Nox A1 PSG System (Nox Medical, Reykjavik, Iceland). The following signals were recorded simultaneously: 6-channel electroencephalography (leads: F3A2, F4A1, C3A2, C4A1, O1A2, O2A1), left and right electrooculography (LOC, ROC), and submental electromyography (3 unipolar leads). In addition, nasal airflow pressure was acquired with a nasal cannula, respiratory effort was assessed with thoracic and abdominal inductive plethysmography, and snoring was recorded using a built-in microphone. Body position and activity were measured with the internal 3-axis, ± 2-g accelerometer with 10 Hz sampling frequency. The device was attached with the clips snapped to the patient’s shirt on the thorax with dimensions of 82 mm W × 63 mm H × 21 mm D and a mass of 163 g. Pulse, oximetry, and plethysmography were measured with a Nonin 3150 WristOx2™ wireless oximeter (Nonin Medical, Plymouth, MN, USA). Subjects were supervised by a polysomnographic technician.

Sleep staging and respiratory scoring were interpreted by a sleep physician using the standard criteria defined by the American Academy of Sleep Medicine [4]. The apnea-hypopnea index was defined as the combined number of apneas and hypopneas that occurred per hour of sleep. Hypopnea was defined as a 30% decrease in airflow for at least 10 s, followed by a 4% decrease in saturation. Respiratory event-related arousals (RERAs) were not scored by the sleep laboratory.

Home sleep apnea test

The home-based sleep study was performed using the WatchPAT™200 (Itamar Medical Ltd., Caesarea, Israel) portable sleep apnea diagnostic system, which tracks peripheral arterial tonometry, oximetry, heart rate, actigraphy, body position, and snoring.

The body position sensor used a 3-axis accelerometer that produced a signal directly proportional to the patient’s sleeping posture (supine, prone, right side, left side, and sitting) with a sampling frequency of 100 Hz. The sensor was attached with an adhesive sticker on the patient’s chest right under the sternal notch. The sensor was 32 mm in diameter with a mass of 12 g.

A sleep technician instructed each patient on how to affix the sensors to ensure proper placement of a device on the same day that the study was carried out. The study was automatically analyzed using Itamar’s software which uses a 4% desaturation criteria.

Statistical analysis

Because the data was not normally distributed, the Mann-Whitney test was used to compare variables between PSG and HSAT groups. Linear regression models were applied to predict if any factor (as sex, age, BMI, or study type) influences supine position sleep. Statistical analysis was performed using IBM SPSS Statistics for Windows, version 20 (IBM Corp., Armonk, N.Y., USA).

Results

There were 445 PSG and 416 HSAT studies analyzed. The mean age of the HSAT cohort was younger at 48.7 ± 13.8 years than for the PSG group at 54.1 ± 13.3 years (p < 0.001). Women constituted 31% (138) of patients undergoing PSG and 12% (50) of those undergoing HSAT (p < 0.001). The patients undergoing HSAT also had a lower BMI (29.7 ± 5.6 kg/m2) than those patients undergoing PSG (31.1 ± 5.9 kg/m2, p < 0.001).

As seen in Table 1, there was no significant difference in the overall proportion of sleep time spent in the supine position in the cohorts undergoing PSG (44.1%) versus those who underwent HSAT (44.6%, p = 0.53) despite longer TST for the HSAT group than the PSG group (p < 0.001). The overall AHI for the PSG group (23.1 ± 41.4 events/h) was higher than the pAHI (17.5 ± 22.6 events/h) for the HSAT group (p = 0.009).

Table 1.

Baseline demographic data for adults undergoing either HSAT or PSG testing to assess for obstructive sleep apnea

Sleep test n Mean (SD) p value*
Age (years) HSAT 416 48.7 (13.8) < 0.001
PSG 445 54.1 (13.3)
BMI (kg/m2) HSAT 414 29.7 (5.6) < 0.001
PSG 435 31.1 (5.9)
Sleep time (minutes) HSAT 416 405.2 (57.4) < 0.001
PSG 445 379.7 (31.1)
Supine (%) HSAT 416 44.6 (25.1) 0.528
PSG 445 44.1 (27.2)

pAHI

AHI

HSAT 416 17.5 (22.6) 0.009
PSG 445 23.1 (41.4)

HSAT, home sleep apnea testing; PSG, polysomnography; SD, standard deviation; BMI, body mass index; n, number; pAHI, PAT (peripheral arterial tone) apnea hypopnea index; AHI, apnea hypopnea index; *, Mann-Whitney test

The significance was for p < 0.05

Table 2 shows the differences in percentage of total sleep in the supine position subgrouped by sex, BMI (≥ 30 kg/m2 versus < 30 kg/m2), and age (≥ 60 years versus < 60 years). The only significant finding was that women had more supine sleep during HSAT (60.8 ± 23.9%) than they did during PSG (45.4 ± 25.8%, p < 0.001). In the PSG group, the mean supine AHI was 46.87 ± 30.23 events/h compared with 23.14 ± 41.37 non-supine. For the HSAT group, the mean supine AHI was 29.58 ± 26.56 events/h compared with 17.47 ± 22.59 non-supine.

Table 2.

HSAT and PSG percentage of supine sleep for adults undergoing evaluation for obstructive sleep apnea subgrouped by sex, body mass index (BMI), and age

Sleep position Sleep study n Mean (SD) p value*
Sex
Female
Supine (%) HSAT 50 60.8 23.9 < 0.001
PSG 138 45.4 25.8
Male
Supine (%) HSAT 366 42.4 24.5 0.943
PSG 307 43.5 27.8
BMI
< 30 kg/m2
Supine (%) HSAT 238 46.5 25.5 0.863
PSG 216 46.2 26.8
≥ 30 kg/m2
Supine (%) HSAT 176 41.9 24.6 0.442
PSG 219 41.2 27.1
Age, year
< 60
Supine (%) HSAT 308 45.4 24.3 0.679
PSG 260 46.8 26.4
≥ 60
Supine (%) HSAT 108 42.4 27.4 0.451
PSG 185 40.3 27.8

HSAT, home sleep apnea testing; PSG, polysomnography; SD, standard deviation; n, number; kg, kilograms; m, meter; BMI, body mass index; pAHI, PAT (peripheral arterial tone) apnea hypopnea index; AHI, apnea hypopnea index; *, Mann-Whitney test

differences are signifficant at p < 0.05

Regression analysis of study type as a predictor of supine sleep, when controlled for sex, age, and BMI, showed that (1) women spent 8.1% more sleep time supine than did men, (2) each increase in year of age was associated with a 0.2% decrease in total sleep time in the supine position, (3) each increase of 1 in the BMI score decreased total sleep time in the supine position by 0.5%, and (4) the study type did not significantly influence the likelihood of supine sleep.

Discussion

Overall, we found no difference in the percentage of supine sleep when comparing patients who underwent a traditional in-laboratory PSG to those assessed with a HSAT despite the fact that those undergoing HSAT were younger, had a slightly lower BMI, and had longer sleep time. Moreover, the supine AHI was higher than the non-supine AHI with both the HSAT and PSG testing. Subgroup analysis revealed that women had significantly more supine sleep with HSAT than was seen in the sleep laboratory; however, there were no differences noted for men, or when assessing this cohort by BMI or age. Literature review revealed only one mention of a percent of supine sleep for men and women, separately [9], showing a slightly higher value for women (40.5% (± 18.6)) than men (35.1% (± 18.2)).

In 1985, Cartwright et al. wrote that “Patients sometimes report in the morning that they spent more time in this (supine) position during their laboratory evaluation than they typically do at home. Sleep disorders centers need to recognize the contribution of body position to their estimation of sleep apnea severity and therefore instruct patients to occupy their usual sleep postures if possible” [7]. This is a significant concern given that many OSA patients have upper airway obstruction that is most prominent while sleeping supine, known as positional OSA (POSA). There are currently two types of POSA. The first is supine predominant obstructive sleep apnea (spOSA) where the whole-night AHI is ≥5 events/h and the supine AHI is greater than twice the non-supine AHI; this is reported to occur in up to 60% of patients who present to sleep clinics [10, 11]. The second type, which occurs in up to 30%, is supine isolated obstructive sleep apnea (siOSA) where the whole-night AHI is ≥ 5 events/h and the supine AHI is greater than twice the non-supine AHI but the non-supine AHI does not exceed 5 events/h [1214].

A 2014 review article by Joosten et al. concluded that “the amount of time spent in supine sleep in unselected general population is not known” [12]. Similarly, Sorscher et al. in 2018 identified the need for research regarding body position during sleep with respect to normative data as well as night to night variability [15].

Table 3 includes the rates of supine sleep previously reported in the literature. Metersky et al. reported that 9 out of 12 patients spent 56% more time in the supine position during PSG night than during subsequent nights in the laboratory when not connected to the monitoring leads [8]. Our results did not confirm this but instead showed that the percentage of supine sleep was similar during multi-channel PSG and HSAT. We can speculate that the PSG used by Metersky et al. in the 1990s’ was more “uncomfortable” than the PSG used in our study and may have had greater impact on the sleep position. Similarly, a large-scale retrospective study (n = 168) by Vonk et al. analyzed the rate of supine sleep during in-lab PSG and compared it to the home sleep during the inactive (diagnostic) phase of sleep position trainer (SPT) [16]. While they found that there was a significant difference in the percent of supine sleep between PSG (43.1%) and SPT night (28.6%), all participants had positional OSA, which could have biased the results. Additionally, the authors informed all patients to avoid supine sleep before the SPT nights.

Table 3.

Comparison of previously published studies which report data on the percentage of supine sleep during a sleep study

Study Number of patients Sleep test type % of supine sleep
Sunnergren et al. 189 HSAT (Embletta) 39
Campbell and Neill 30

Home PSG (Compumedics Siesta)

PSG

41.4

36

Sorscher et al. 49 HSAT (ApneaTrak, Cadwell) 41.2
Yin et al. 90 HSAT (Stardust II, Respironics) PSG

51.3

62.7

Metersky et al. 12 PSG 49

HSAT, home sleep apnea testing; PSG, polysomnography

A study by Skarpsno assessed multi-night actigraphic recordings of 664 adults recruited from the general population and reported that 37.5% of total time in bed was spent supine [9]. Similar proportions of supine sleep were reported in studies by Sunnergren et al. (39%), Campbell and Neill (36–41%), and Sorscher et al. (41%), while Yin et al. reported a higher proportion of supine sleep in his cohort during both in-laboratory (62%) and at-home PSG (51%) [15, 1719]. Our findings were similar to the preponderance of studies with supine sleep seen 44% of the time for both the in-laboratory PSG and HSAT cohorts.

Limitations of this study include its retrospective nature and the selection bias implicit in using two separate groups for the comparison. While this is a pragmatic approach, ideally future studies would compare the influence of in-laboratory versus HSAT devices on sleep positions in a single cohort. In addition, while there were differences in the mean age and BMI between these 2 cohorts, subgroup analysis did not reveal any significant differences in sleep position based on these variables. Lastly, our data was collected from a single night study and thus cannot provide information about night-to-night variability of body position during sleep.

Conclusion

We found that patients slept supine for 44% of TST in both the in-laboratory PSG and HSAT cohorts, despite differences in age and BMI between the two groups. While there are concerns that in-laboratory testing may significantly influence body position during sleep, this was not the case in our study. Women did have more supine sleep when tested in the home setting, but no differences were seen for men or in the overall cohort.

Acknowledgments

We thank Dr. Piotr Bielicki of the Department of Pulmonology, Medical University of Warsaw, and Dr. Adam Wichniak of the Third Department of Psychiatry and Sleep Disorders Center, Institute of Psychiatry and Neurology in Warsaw, for sharing the anonymized PSG data, which were used in the study.

Compliance with ethical standards

Conflict of interest

Author Stacey L. Ishman has received money for consultation from Inspire Company. Author Wojciech Kukwa is a shareholder of Clebre Company. Authors Ewa Migacz and Tomasz Lis declare that they have no conflict of interest. The authors did not receive any financial support for preparation of this paper.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. In addition, the Bioethical Committee of the Medical University of Warsaw approved this study.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Zychowski KE, Sanchez B, Pedrosa RP, Lorenzi-Filho G, Drager LF, Polotsky VY, Campen MJ. Serum from obstructive sleep apnea patients induces inflammatory responses in coronary artery endothelial cells. Atherosclerosis. 2016;254:59–66. doi: 10.1016/j.atherosclerosis.2016.09.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Douglas NJ, Thomas S, Jan MA. Clinical value of polysomnography. Lancet. 1992;339(8789):347–350. doi: 10.1016/0140-6736(92)91660-Z. [DOI] [PubMed] [Google Scholar]
  • 3.Kushida CA, Littner MR, Morgenthaler T, Alessi CA, Bailey D, Coleman J, Jr, Friedman L, Hirshkowitz M, Kapen S, Kramer M, Lee-Chiong T, Loube DL, Owens J, Pancer JP, Wise M. Practice parameters for the indications for polysomnography and related procedures: an update for 2005. Sleep. 2005;28(4):499–521. doi: 10.1093/sleep/28.4.499. [DOI] [PubMed] [Google Scholar]
  • 4.Kapur VK, Auckley DH, Chowdhuri S, Kuhlmann DC, Mehra R, Ramar K, Harrod CG. Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of Sleep Medicine clinical practice guideline. J Clin Sleep Med. 2017;13(3):479–504. doi: 10.5664/jcsm.6506. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Hirshkowitz M. Polysomnography: understanding this technology's past might guide future developments. IEEE Pulse. 2014;5(5):26–28. doi: 10.1109/MPUL.2014.2339291. [DOI] [PubMed] [Google Scholar]
  • 6.Su S, Baroody FM, Kohrman M, Suskind D. A comparison of polysomnography and a portable home sleep study in the diagnosis of obstructive sleep apnea syndrome. Otolaryngol Head Neck Surg. 2004;131(6):844–850. doi: 10.1016/j.otohns.2004.07.014. [DOI] [PubMed] [Google Scholar]
  • 7.Cartwright RD, Lloyd S, Lilie J, Kravitz H. Sleep position training as treatment for sleep apnea syndrome: a preliminary study. Sleep. 1985;8(2):87–94. doi: 10.1093/sleep/8.2.87. [DOI] [PubMed] [Google Scholar]
  • 8.Metersky ML, Castriotta RJ. The effect of polysomnography on sleep position: possible implications on the diagnosis of positional obstructive sleep apnea. Respiration. 1996;63(5):283–287. doi: 10.1159/000196561. [DOI] [PubMed] [Google Scholar]
  • 9.Skarpsno ES, Mork PJ, Nilsen TIL, Holtermann A. Sleep positions and nocturnal body movements based on free-living accelerometer recordings: association with demographics, lifestyle, and insomnia symptoms. Nat Sci Sleep. 2017;9:267–275. doi: 10.2147/NSS.S145777. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Oksenberg A, Silverberg DS, Arons E, Radwan H. Positional vs nonpositional obstructive sleep apnea patients: anthropomorphic, nocturnal polysomnographic, and multiple sleep latency test data. Chest. 1997;112(3):629–639. doi: 10.1378/chest.112.3.629. [DOI] [PubMed] [Google Scholar]
  • 11.Richard W, Kox D, den Herder C, Laman M, van Tinteren H, de Vries N. The role of sleep position in obstructive sleep apnea syndrome. Eur Arch Otorhinolaryngol. 2006;263(10):946–950. doi: 10.1007/s00405-006-0090-2. [DOI] [PubMed] [Google Scholar]
  • 12.Joosten SA, O'Driscoll DM, Berger PJ, Hamilton GS. Supine position related obstructive sleep apnea in adults: pathogenesis and treatment. Sleep Med Rev. 2014;18(1):7–17. doi: 10.1016/j.smrv.2013.01.005. [DOI] [PubMed] [Google Scholar]
  • 13.Mador MJ, Kufel TJ, Magalang UJ, Rajesh SK, Watwe V, Grant BJ. Prevalence of positional sleep apnea in patients undergoing polysomnography. Chest. 2005;128(4):2130–2137. doi: 10.1378/chest.128.4.2130. [DOI] [PubMed] [Google Scholar]
  • 14.Joosten SA, Hamza K, Sands S, Turton A, Berger P, Hamilton G. Phenotypes of patients with mild to moderate obstructive sleep apnoea as confirmed by cluster analysis. Respirology. 2012;17(1):99–107. doi: 10.1111/j.1440-1843.2011.02037.x. [DOI] [PubMed] [Google Scholar]
  • 15.Sorscher AJ, Anzivino AP, Mackenzie T. Patient-predicted sleep position vs. HST data: a tendency to underestimate supine sleep. Sleep Breath. 2018;22(3):625–630. doi: 10.1007/s11325-017-1589-z. [DOI] [PubMed] [Google Scholar]
  • 16.Vonk PE, de Vries N, Ravesloot MJL. Polysomnography and sleep position, a Heisenberg phenomenon? : A large-scale series. HNO. 2019;67(9):679–684. doi: 10.1007/s00106-019-0678-7. [DOI] [PubMed] [Google Scholar]
  • 17.Sunnergren O, Brostrom A, Svanborg E. Positional sensitivity as a confounder in diagnosis of severity of obstructive sleep apnea. Sleep Breath. 2013;17(1):173–179. doi: 10.1007/s11325-012-0666-6. [DOI] [PubMed] [Google Scholar]
  • 18.Campbell AJ, Neill AM. Home set-up polysomnography in the assessment of suspected obstructive sleep apnea. J Sleep Res. 2011;20(1 Pt 2):207–213. doi: 10.1111/j.1365-2869.2010.00854.x. [DOI] [PubMed] [Google Scholar]
  • 19.Yin M, Miyazaki S, Ishikawa K. Evaluation of type 3 portable monitoring in unattended home setting for suspected sleep apnea: factors that may affect its accuracy. Otolaryngol Head Neck Surg. 2006;134(2):204–209. doi: 10.1016/j.otohns.2005.10.019. [DOI] [PubMed] [Google Scholar]

Articles from Sleep & Breathing = Schlaf & Atmung are provided here courtesy of Springer

RESOURCES