Abstract
Firefighters’ uniforms become contaminated with a wide range of chemicals, including polycyclic aromatic hydrocarbons (PAHs), organophosphate flame retardants (OPFRs), and polybrominated diphenyl ethers (PBDEs). Laundering practices do not completely remove PAHs, OPFRs, and PBDEs from firefighting uniforms. This residual contamination of firefighting ensembles may be an ongoing source of exposure to firefighters. Firefighters are known to occasionally store firefighting ensembles in private vehicles. This study aimed to assess whether a firefighting uniform in a vehicle could act as a source for PAHs, OPFRs, and PBDEs to vehicle users. The shell layers of four laundered firefighting uniforms were sampled non-destructively. Three of these uniforms were heated in a laboratory oven (40, 60, and 80 °C) while the fourth was placed in a private vehicle on a summer day and off-gassing samples were collected from the uniforms. The off-gassing results for PAHs and OPFRs were relatively consistent between laboratory oven and the in-vehicle sample with ∑13 PAHs in off-gas ranging from 7800–23,000 ng uniform−1 day−1, while the ∑6 OPFRs off-gassed was an order of magnitude lower at 620–1600 ng uniform−1 day−1. The off-gassing results for PBDEs were much lower and less consistent between the experiments, which may reflect differences in uniform history. Currently, there is limited understanding of how PAHs, OPFRs, and PBDEs off-gassed from firefighting uniforms influence firefighter exposure to these chemicals. These findings suggest that firefighting ensembles off-gassing in private vehicles could be a relevant source of PAHs, OPFRs, and PBDEs that contributes to firefighters’ exposure and that this warrants further investigation.
Keywords: polycyclic aromatic hydrocarbons (PAHs), organophosphorus flame retardants (OPFRs), polybrominated diphenyl ethers (PBDEs), firefighters, uniform, off-gassing
1. Introduction
Firefighters are exposed to a range of chemicals while attending fire scenes, including polycyclic aromatic hydrocarbons (PAHs), organophosphate flame retardants (OPFRs), and polybrominated diphenyl ethers (PBDEs). The exposure to PAHs is the result of partial combustion of organic materials. OPFRs and PBDEs are used as flame retardants, in a wide range of products and materials, and can be released from these materials during combustion [1,2]. After firefighters have attended fire scenes, the clothing and equipment worn to protect themselves inevitably become contaminated with residues from the fire [3,4,5].
Laundering practices are ineffective in completely removing PAHs, OPFRs, and PBDEs from firefighting uniforms [6,7,8,9]. It has been suggested that firefighting ensembles could potentially be a vector for exposure to firefighters, with storage conditions potentially determining the exposure pathway to firefighters [10,11]. It has also been shown that firefighting uniforms may subsequently contribute to elevated semi-volatile organic compounds (SVOC) concentrations in dust at the locations where this gear is stored [12].
Australian firefighters are known to occasionally store firefighting ensembles in private vehicles, often in anticipation of being called in while off-duty during summer and fire seasons. This is not purely an Australian phenomenon; with it being reported that career and volunteer firefighters in the United States also store firefighting uniforms in private vehicles [13,14]. In the United States, PAHs in surface wipes from fire engines and firefighters’ vehicles were of similar concentrations with the storage of firefighting uniforms in vehicles hypothesised as the source of these PAHs [15].
There is concern that firefighting uniforms stored in private vehicles may present a source of exposure to off-duty firefighters as well as other passengers that regularly use their vehicles, such as family members. Elevated heat inside a private vehicle may further increase the rate at which SVOCs are transported from firefighting uniforms into private vehicles. The aim of this study was to assess whether a used and laundered firefighting uniform left in a vehicle may act as an emissions source for selected SVOCs. It also aimed to assess how changes in temperature affect the rate of off-gassing.
2. Materials and Methods
2.1. Experimental Overveiw
The outer shell layers of four structural firefighting uniforms were sampled for PAHs, OPFRs, and PBDEs. Three of these uniforms were heated in a laboratory oven at 40, 60, and 80 °C, while the fourth was placed in a private vehicle. The uniforms were sampled for PAHs, OPFRs, and PBDEs that were off-gassed from them for 24 h (see Section 2.3. Sample Collection). The temperature in the vehicle was monitored over this time period using a temperature data logger Digitech QP6014. Sampling was conducted in January 2020.
2.2. Uniform Selection
Four sets of structural firefighting uniforms were used in this study. Three uniforms had a history of being used for thermal testing use at a firefighter training facility. These three uniforms were placed in the ovens at 40, 60, and 80 °C. The fourth uniform was collected from an active fire service member who had recently attended a house fire. This uniform was used for in-vehicle sampling. All four uniforms were the same make and model, although the comprehensive history and time in service of each uniforms was not known. The uniforms had been laundered by fire services industrial laundering contractor since their last use.
2.3. Sample Collection
2.3.1. Uniforms
The samples were collected from the outer shell layer of four sets of structural firefighting jackets and trousers prior to off-gassing sampling. Banks et al. previously described the technique used to sample these uniforms [9]. The shell layer was placed onto a filtration manifold (50 mm diameter) and 50 mL of isopropanol was drawn though the fabric at a rate of 1 mL second−1. The shell layer extracts from the jacket and trousers in each sample set were combined. The sample extracts were then spiked with internal standards (500 ng D10-Phe, 200 ng D10-Flu, 50 ng each of D12-Chr, D12-BbF, D12-BaP, D12-I123cdP and D12-BghiP, 10ng each of D18-TCIPP, D15-TPhP and D27-TNBP, and 1ng of 13C12-PBDE mixture). The sample extracts were taken to near-dryness and made up in 50 µL of recovery standard (10 ng 13C12-BDE 77) in isooctane. The results were converted to ng g−1 while using the measured density of the shell layer of 229 g m−2.
2.3.2. Off-Gassing
Sets of structural firefighting jackets and trousers were placed into a polypropylene bag. The bag contained an 8mm sampling port on one side of the bag and a separate 8 mm inflow port on the other side of the bag. The inflow port was connected to an XAD-2 (~20 g) pre-treatment to remove PAHs, OPFRs, and PBDEs from the ambient air before being drawn into the polypropylene bag. The sampling port was connected to a stainless-steel sampling probe, which was attached to a low-volume active air sampler (LSAM-100 (SAICI Technology Co., Ltd., Dalian, China) operating at 0.22 m3 h−1 that drew gas through XAD-2 (5g), where PAHs, OPFRS, and PBDEs are trapped. The collected sample included the XAD-2, and the solvent rinses from tubing and all of the glassware in the sampling train. After sample collection, the sampling train was stored at −20 °C until analysis.
Prior to extraction, the samples were spiked with internal standards (500 ng D10-Phe, 200 ng D10-Flu, 50 ng each of D12-Chr, D12-BbF, D12-BaP, D12-I123cdP and D12-BghiP, 10 ng each of D18-TCIPP, D15-TPhP and D27-TNBP, and 1ng of 13C12-PBDE mixture). The sample was extracted using 50 mL of 1:1 acetone:n-hexane solution in an ultra-sonic bath for 60 min. The solvent was removed and this was repeated with a further 50 mL of 1:1 acetone:n-hexane. These solvent extracts were taken to near-dryness and made up in 1 mL of DCM.
The sample extracts were then cleaned up by gel permeation chromatography (GPC), while using a Shimadzu LC-20AC (Shimadzu, Kyoto, Japan) system coupled with an EnvirogelTM GPC Guard Column 4.6 × 30 mm (Waters), an EnvirogelTM GPC Cleanup Column 19 × 300 mm (Waters), and a Shimadzu FRC-10A fraction collector. The mobile phase solvent was DCM, pumped at a flow rate of 5 mL min−1. 500 µL of the filtered DCM extract was injected onto the column. The sample was collected from 8.33 until 16.32 min. The collected fraction was then blown down to near-dryness and reconstituted in 50 µL of recovery standard (10 ng 13C12-BDE 77) in isooctane.
2.4. Analysis
The analysis methods used have been previously described in-depth [10,16,17]. In summary, the extracts were analysed using a TRACE GC Ultra (Thermo Fisher Scientific, Waltham, MA, USA) coupled to a TSQ Quantum XLS (Thermo Fisher Scientific, Waltham, MA, USA) triple quadrupole mass spectrometer that was equipped with a TriPlus Autosampler. A DB-5MS column (30 m × 0.25 mm i.d.; 0.25 µm film thickness, J&W Scientific) was used for separation. The oven temperature was programmed as follows: Initial temperature was 80 °C for 2 min and increased to 180 °C at 20 °C min−1 and held for 0.5 min, then to 300 °C at 10 °C min−1 and held at this temperature for 5 min. The total run-time was 25 min at constant flow rate of 1.0 mL min−1. The volume injected was 1.0 μL, in splitless mode. The QqQ mass spectrometer was operated inelectron ionization(EI) mode using the multiple reactions monitoring (MRM) mode with an emission current set at 20 μA. Table 1 presents the list of target compounds analysed.
Table 1.
List of targeted compounds.
Chemicals | Abbreviation | CAS Number |
---|---|---|
PAHs | ||
Phenanthrene | Phe | 85-01-8 |
Anthracene | Ant | 120-12-7 |
Fluoranthene | Flu | 86-73-7 |
Pyrene | Pyr | 129-00-0 |
Chrysene | Chr | 218-01-9 |
Benz[a]anthracene | BaA | 56-55-3 |
Benzo[b]fluoranthene | BbF | 205-99-2 |
Benzo[k]fluoranthene | BkF | 207-08-9 |
Benzo[e]pyrene | BeP | 192-97-2 |
Benzo[a]pyrene | BaP | 50-32-8 |
Indeno[1,2,3-c,d]pyrene | I123cdP | 193-39-5 |
Dibenzo[a,h]anthracene | DahA | 200-181-8 |
Benzo[ghi]perylene | BghiP | 191-24-2 |
OPFRs | ||
Tris(1,3-dichloroisopropyl) phosphate | TDCIPP | 13674-87-8 |
Tris(2-butoxyehyl) phosphate | TBOEP | 78-51-3 |
Triphenyl phosphate | TPhP | 115-85-6 |
2-ethylhexyl diphenyl phosphate | EHDPP | 1241-94-7 |
Tris(2-ethylhexyl) phosphate | TEHP | 78-42-2 |
Tris(2-methylphenyl) phosphate | TMPP | 78-30-8 |
PBDEs | ||
2,4,4′-tribromodiphenyl ether | BDE-28 | 41318-75-6 |
2,2′,4,4′-tetrabromodiphenyl ether | BDE-47 | 5436-43-1 |
2,2′,4,4′,5-pentabromodiphenyl ether | BDE-99 | 60348-60-9 |
2,2′,4,4′,6-pentabromodiphenyl ether | BDE-100 | 189084-64-8 |
2,2′,4,4′,5,5′-hexabromodiphenyl ether | BDE-153 | 68531-49-2 |
2,2′,4,4′,5,6′-hexabromodiphenyl ether | BDE-154 | 207122-15-4 |
2,2′,3,4,4′,5′,6-heptabromodiphenyl ether | BDE-183 | 207122-16-5 |
2.5. Quality Assurance and Quality Control
Field blank samples were prepared and analysed alongside the uniforms (n = 3), and off-gassing samples (n = 3). For the uniform samples, glass fibre filters (Whatman) were used as field blanks. For the off-gassing samples, the field blanks consisted of 5g of XAD-2, loaded into the air sampler, before being removed. Subsequently, the sampling train was solvent rinsed, as per sample collection. The blank samples were extracted and analysed alongside the sample batches. Method detection limits (MDLs) were defined as the average blank concentrations plus three times their standard deviations (SDs). Tables S1 and S2 list the MDLs for the individual chemicals in each experiment.
3. Results and Discussion
3.1. Temperature Profile Inside Vehicle Cabin
The average temperature inside the vehicle cabin over 24 h of sampling was 39.7 °C, with a minimum temperature of 25.7 °C and a peak of 75.3 °C (Figure 1).
Figure 1.
Temperature profile inside vehicle cabin.
3.2. Concentrations of PAHs, OPFRs and PBDEs in the Shell Layer of Firefighting Uniforms Profile Inside Vehicle Cabin
The concentrations of PAHs, OPFRs, and PBDEs measured in firefighting uniforms are summarised in Figure 2. The individual chemicals concentrations are presented in the SI (Table S1). All PAHs, TPhP, EHDPP, TEHP, and TMPP were above the MDLs for all analysed uniforms. TBOEP was above the MDL in three of the four uniforms sampled. BDE 100 and 153 were detected above the MDL, each in a single uniform that had previously been used in thermal testing. BDE 47, 99, 100, 154, and 183 were all above the MDL in the shell layer of the active firefighter’s uniform. TDCIPP and BDE 28 were below MDLs in all the analysed uniforms.
Figure 2.
Concentrations of polycyclic aromatic hydrocarbons (PAHs), organophosphate flame retardants (OPFRs), and polybrominated diphenyl ethers (PBDEs) in structural firefighting uniforms (ng g−1) and rate of off-gassing (ng uniform−1 day−1). (< MDL = 0).
The concentrations of ∑13 PAHs in the shell layer of uniforms ranged from 360–570 ng g−1, Phe and Pyr on average, contributing to 32% and 17% of this, respectively. Concentrations of ∑6 OPFRs in the shell layer of uniforms were between 1200–2800 ng g−1 with the highest concentrations being of TPhP and EHDPP. On average, they contributed 67% and 31% of the measured OPFR concentration, respectively. The only PBDEs in the shell layer of uniforms that had been previously used for thermal testing were BDE-100 and BDE 153 that were detected in different uniforms at 0.92 and 0.72 ng g−1, respectively. The concentration of ∑7 PBDEs detected in the shell layer of the firefighting uniform used by the active fire service member was 550 ng g−1, with BDE-99 and BDE-47 contributing to 51% and 38% of this concentration, respectively.
While the PAH and OPFR profiles were similar in all the uniforms, there was a difference in the PBDEs profile between the uniform collected from a fire service member and uniforms that had been used previously used for thermal testing. Unlike the fire service member’s uniform, the uniforms that were used for thermal testing may not have been exposed to PBDEs in sufficient quantities to be measured; this is likely due to the emission from the fires that these uniforms had attended may not have contained PBDEs.
3.3. Rate of PAHs, OPFRs and PBDEs Off-Gassing from Firefighting Uniforms
Figure 2 summarises the rate at which PAHs, OPFRs, and PBDEs off-gassed from firefighting uniforms. The results for individual chemicals are presented in the SI (Table S2). TPhP, TEHP, TMPP, BDE 47, all PAH compounds, with the exception of Pyr, were detected above the MDLs in all collected off-gassing samples. Pyr and TDCIPP were above the MDLs in three of the four samples. EHDPP was above the MDL for two samples, while TBOEP was only above the MDL in a single sample. BDEs 27, 99, 100, 153, 154 and 183 were below the MDL in all collected off-gassing samples.
The rate of ∑13 PAHs off-gassing from the uniforms ranged from 7800–23000 ng uniform−1 day−1. Phe and Ant, on average, contributed to 77% and 9.9% of this, respectively. The rate at which ∑6 OPFRs off-gassed were between 620–2800 ng uniform−1 day−1, with the highest concentrations being from TPhP, which, on average, contributed to 83% of the OPFR emissions. BDE-47 off-gassed from the uniforms between 0.65–53 ng uniform−1 day−1.
3.4. Exposure Implications
The majority of previous research on SVOCs in firefighting uniforms has suggested that dermal exposure from firefighting uniforms may contribute to firefighters’ overall occupational exposure. This study indicates that the off-gassing of chemical contamination from protective clothing into private vehicles may also be a source of chemicals contributing to firefighters’ exposure. This is important, due to the potential ongoing exposure that firefighters may have to chemicals outside of fire scenes. This exposure may be through off-gassing chemicals being directly inhaled or through dermal exposure once they have deposited on surfaces inside vehicles. The ∑13 PAHs, ∑6 OPFRs, and ∑7 PBDEs off-gassed from a firefighter’s uniform in a vehicle was at rates of 12,000, 1200, and 53 ng uniform−1 day−1, respectively. It has been previously proposed that there is a build-up of PAHs in private vehicles where firefighting uniforms are stored [15]. The same is likely true for OPFRs and PBDEs. Currently, there is limited understanding of how PAHs, OPFRs, and PBDEs that off-gas from firefighting uniforms contribute to overall firefighter exposure. Firefighting uniforms contaminating private vehicles may also have exposure implications to other regular users of the vehicles, such as family members. This may be a significant and ongoing source of exposure that necessitates further investigation.
3.5. Factors That May Impact the Emissions
It was hypothesised that warmer temperatures would induce a higher rate of SVOC off-gassing from the contaminated firefighter uniforms. In our study, the temperature did not appear to affect the rate at which PAHs, OPFRs, and PBDEs off-gassed from uniforms. (Figure S1). Instead, the rate at which chemicals off-gassed from firefighting uniforms appeared to be mainly driven by the vapor pressure of individual chemicals. Figure 3 and Figure S1 present a moderate relationship between the vapor pressure and ratio of concentration in the shell layer to the rate of off-gassing.
Figure 3.
Relationship between vapor pressure and the rate at which semi-volatile organic compounds (SVOCs) off-gassed from a structural firefighting uniform in a vehicle.
3.6. Limitations and Perspectives
The sample size of four uniforms used in this study was relatively small and, therefore, a high level of uncertainty may be associated with the study. The sampling method used to measure the off-gassing of PAHs, OPFRs, and PBDEs from firefighting uniforms only sampled chemicals in the gaseous phase and, thus, neglected compounds bound to particles. This may underestimate the amount of target compounds emitted into vehicles. The unknown efficiency of the non-destructive sampling in the removal of PAHs, OPFRs, and PBDEs from shell layers is a further limitation of this study. However, all shell layer samples collected would be equally affected by this. Finally, we were unable to collect samples from thermal liners or moisture barriers inside firefighting jackets and trousers due to this non-destructive method. The emission of SVOCs from these layers, if present, are likely to influence the rate of off-gassing. This could be one of the factors contributing to why a relationship between the temperature and rate of off-gassing was not observed.
4. Conclusions
This study reinforces the need for ongoing research into the removal of SVOCs from firefighters’ uniforms. The findings from this study suggest that firefighting ensembles off-gassing in private vehicles could be a significant source of chemicals that contribute to firefighters’ exposure to PAHs, OPFRs, and PBDEs. Ideally, modified washing techniques that adequately remove SVOCs from firefighting would remove uniforms as a source of this exposure. Until then, there is a need to have a greater understanding of the effectiveness of different storage methods at containing SVOCs off-gassing from firefighters’ uniforms in vehicles.
Acknowledgments
Andrew Banks was the recipient of a QAEHS UQ scholarship. Jochen Mueller was funded by a UQ Fellowship. Xianyu Wang was partly funded by The National Health and Medical Research Council (NHMRC) of Australia. The authors would like to thank the members of an Australian fire services that made this research possible.
Supplementary Materials
The following are available online at https://www.mdpi.com/1660-4601/18/6/3030/s1, Table S1: Concentrations of PAHs, OPFRs and PBDEs in structural firefighting uniforms, Table S2: Rate of PAHs, OPFRs and PBDEs off-gassing from structural firefighting equipment, Figure S1: Relationship between vapor pressure and the rate at which SVOCs off-gassed from a structural firefighting uniform in a vehicle and in laboratory tests.
Author Contributions
Conceptualization, A.P.W.B., X.W. and M.G.; methodology, A.P.W.B., X.W., C.H. and M.G.; writing—original draft preparation, A.P.W.B. and X.W.; writing—review and editing, A.P.W.B., X.W., C.H., K.V.T. and J.F.M..; supervision, X.W., K.V.T. and J.F.M. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The data presented in this study are openly available in the Supplementary Materials document.
Conflicts of Interest
The authors declare no conflict of interests.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Bendig P., Haägele F., Blumenstein M., Schmidt J., Vetter W. Fate of polybrominated diphenyl ethers during cooking of fish in a new model cooking apparatus and a household microwave. J. Agric. Food Chem. 2013;61:6728–6733. doi: 10.1021/jf4013696. [DOI] [PubMed] [Google Scholar]
- 2.Harris D., Davis A., Ryan P.B., Cohen J., Gandhi P., Dubiel D., Black M. Chemical exposure and flammability risks of upholstered furniture. Fire Mater. 2021;45:167–180. doi: 10.1002/fam.2907. [DOI] [Google Scholar]
- 3.Shen B., Whitehead T.P., Gill R., Dhaliwal J., Brown F.R., Petreas M., Patton S., Hammond S.K. Organophosphate flame retardants in dust collected from United States fire stations. Environ. Int. 2018;112:41–48. doi: 10.1016/j.envint.2017.12.009. [DOI] [PubMed] [Google Scholar]
- 4.Shen B., Whitehead T.P., McNeel S., Brown F.R., Dhaliwal J., Das R., Israel L., Park J.-S., Petreas M. High levels of polybrominated diphenyl ethers in vacuum cleaner dust from California fire stations. Environ. Sci. Technol. 2015;49:4988–4994. doi: 10.1021/es505463g. [DOI] [PubMed] [Google Scholar]
- 5.Oliveira M., Slezakova K., Alves M.J., Fernandes A., Teixeira J.P., Delerue-Matos C., do Carmo Pereira M., Morais S. Polycyclic aromatic hydrocarbons at fire stations: Firefighters’ exposure monitoring and biomonitoring, and assessment of the contribution to total internal dose. J. Hazard. Mater. 2017;323:184–194. doi: 10.1016/j.jhazmat.2016.03.012. [DOI] [PubMed] [Google Scholar]
- 6.Fent K.W., Alexander B., Roberts J., Robertson S., Toennis C., Sammons D., Bertke S., Kerber S., Smith D., Horn G. Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures. J. Occup. Environ. Hyg. 2017;14:801–814. doi: 10.1080/15459624.2017.1334904. [DOI] [PubMed] [Google Scholar]
- 7.Mayer A.C., Fent K.W., Bertke S., Horn G.P., Smith D.L., Kerber S., La Guardia M.J. Firefighter hood contamination: Efficiency of laundering to remove PAHs and FRs. J. Occup. Environ. Hyg. 2019;16:129–140. doi: 10.1080/15459624.2018.1540877. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Abrard S., Bertrand M., De Valence T., Schaupp T. French firefighters exposure to Benzo [a] pyrene after simulated structure fires. Int. J. Hyg. Environ. Health. 2019;222:84–88. doi: 10.1016/j.ijheh.2018.08.010. [DOI] [PubMed] [Google Scholar]
- 9.Banks A.P., Wang X., Engelsman M., He C., Osorio A.F., Mueller J.F. Assessing decontamination and laundering processes for the removal of polycyclic aromatic hydrocarbons and flame retardants from firefighting uniforms. Environ. Res. 2021;194:110616. doi: 10.1016/j.envres.2020.110616. [DOI] [PubMed] [Google Scholar]
- 10.Banks A.P.W., Engelsman M., He C., Wang X., Mueller J.F. The occurrence of PAHs and flame-retardants in air and dust from Australian fire stations. J. Occup. Environ. Hyg. 2020;17:73–84. doi: 10.1080/15459624.2019.1699246. [DOI] [PubMed] [Google Scholar]
- 11.Park J.-S., Voss R.W., McNeel S., Wu N., Guo T., Wang Y., Israel L., Das R., Petreas M. High exposure of California firefighters to polybrominated diphenyl ethers. Environ. Sci. Technol. 2015;49:2948–2958. doi: 10.1021/es5055918. [DOI] [PubMed] [Google Scholar]
- 12.Peaslee G.F., Wilkinson J.T., McGuinness S.R., Tighe M., Caterisano N., Lee S., Gonzales A., Roddy M., Mills S., Mitchell K. Another Pathway for Firefighter Exposure to Per-and Polyfluoroalkyl Substances: Firefighter Textiles. Environ. Sci. Technol. Lett. 2020;7:594–599. doi: 10.1021/acs.estlett.0c00410. [DOI] [Google Scholar]
- 13.Hwang J., Taylor R., Macy G., Cann C., Golla V. Comparison of Use, Storage, and Cleaning Practices for Personal Protective Equipment Between Career and Volunteer Firefighters in Northwestern Kenkucky in the United States. J. Environ. Health. 2019;82:8–14. [Google Scholar]
- 14.Macy G.B., Hwang J., Taylor R., Golla V., Cann C., Gates B. Examining Behaviors Related to Retirement, Cleaning, and Storage of Turnout Gear Among Rural Firefighters. Workplace Health Saf. 2020;68:129–138. doi: 10.1177/2165079919882951. [DOI] [PubMed] [Google Scholar]
- 15.Hwang J., Taylor R., Cann C., Norris P., Golla V. Evaluation of accumulated polycyclic aromatic hydrocarbons and asbestiform fibers on firefighter vehicles: Pilot study. Fire Technol. 2019;55:2195–2213. doi: 10.1007/s10694-019-00851-7. [DOI] [Google Scholar]
- 16.He C., Wang X., Thai P., Baduel C., Gallen C., Banks A., Bainton P., English K., Mueller J.F. Organophosphate and brominated flame retardants in Australian indoor environments: Levels, sources, and preliminary assessment of human exposure. Environ. Pollut. 2018;235:670–679. doi: 10.1016/j.envpol.2017.12.017. [DOI] [PubMed] [Google Scholar]
- 17.Wang X., Banks A.P.W., He C., Gallen C., Drage D., Li Y., Li Q., Thai P.K., Mueller J.F. Polycyclic aromatic hydrocarbons, polychlorinated biphenyls and legacy and current pesticides in indoor environment in Australia—Occurrence, sources and exposure risks. Sci. Total Environ. 2019;693:133588. doi: 10.1016/j.scitotenv.2019.133588. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The data presented in this study are openly available in the Supplementary Materials document.