Association of Hospital Volume with 30-Day Readmission Following Left Ventricular Assist Device Implantation

Udhay Krishnan 1, Aayush Visaria 2, Samprit Banerjee 3, Luke K Kim 1, Maria G Karas 1, Irina Sobol 1, Evelyn M Horn 1, Parag Goyal 1,4
PMCID: PMC8019493  NIHMSID: NIHMS1633195  PMID: 32151635

Readmissions within 30 days after left ventricular assist device (LVAD) implantation are common, occurring in 30% of patients (1). This is important because 30-day readmissions increase patient morbidity and are costly to the healthcare system. Recent studies have shown an inverse relationship between hospital procedural volume and readmission rates for other interventions performed in patients with HF including trans-catheter mitral valve repair and trans-catheter aortic valve replacement (2, 3). Whether a similar relationship exists for LVAD implantation is unknown. The purpose of this study was to examine whether LVAD hospital volume was independently associated with 30-day all-cause readmission rates after LVAD implantation using the Nationwide Readmissions Database (NRD).

Details of the NRD have been described previously (2). Briefly, the NRD is the largest nationally-representative all-payer inpatient administrative database in the United States. We examined patients aged ≥18 years discharged alive following LVAD implantation in January-November 2014 using the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) code 37.66. Similar to prior studies, we excluded patients discharged in December 2014 since patients are only tracked across hospitals within a given calendar year and complete 30-day readmission data is not available for December. We also excluded patients with missing data for length of stay or patient linkage number because this precluded identification of a 30-day readmission.

To determine hospital volume quartile for LVAD implantation, we calculated the total number of LVAD implantations performed at each hospital between January 1st and December 31st 2014, and classified patients into quartiles based on hospital volume. The primary outcome was 30-day all-cause readmission.

To determine whether LVAD hospital volume was independently associated with 30-day all-cause readmission, we constructed a multivariable logistic regression model incorporating: age, sex, payer status, income quartile, discharge disposition, Elixhauser weighted comorbidity index (4), coronary artery disease, atrial and ventricular arrhythmias, use of mechanical circulatory support, and pre-implant and post-implant length of stay.

For all analyses, we accounted for the complex survey design by using stratification and cluster variables. We weighted the data to produce nationally-representative estimates. For missing data (11% for pre- and post-implant length of stay; 2.9% for income quartile; 1.1% for payer status), we used multiple imputation. We conducted analyses using SAS 9.4 (Cary, North Carolina). All p-values were two-sided with significance threshold <0.05.

We examined 1,311 eligible patients who underwent LVAD implantation from 80 hospitals. Mean age was 56.1±0.5 years and 32.3% were women (Table). Median hospital volume in 2014 was 40 LVAD implantations. The majority of LVAD implantations were performed in large, urban, teaching hospitals across all quartiles. In-hospital mortality rates were similar between the lowest (≤23 implantations) and highest volume quartiles (16.1% vs. 12.4%, p=0.11).

Table 1.

Differences According to LVAD Hospital Procedure Volume, N (%) unless otherwise noted

Entire Cohort 1stQuartile (≤ 23) 2nd Quartile (24-40) 3rd Quartile (41-49) 4th Quartile (≥50) P-value
Number 1,311 324 354 325 308
Age, mean years (SD) 56.1 (0.5) 56.6 (1.0) 54.6 (1.3) 56.4 (0.8) 56.7 (0.7) 0.39
Male sex 1035 (77.7) 260 (77.4) 274 (78.3) 256 (77.4) 245 (77.7) 0.58
Discharge Disposition 0.03
Home without services 418 (27.6) 115 (33.3) 120 (35.9) 92 (20.9) 91 (22.8)
Short-term hospital 44 (2.7) 4 (1.0) 15 (3.6) 15 (3.9) 10 (2.3)
Skilled Nursing Facility or Other 127 (11.8) 32 (9.7) 19 (6.0) 20 (6.0) 56 (21.5)
Home Health Care 722 (57.9) 173 (56.0) 200 (54.6) 198 (69.2) 151 (53.4)
Elixhauser Comorbidity Index, mean (SD) 24.9 (1.4) 25.2 (1.3) 23.8 (3.9) 27.2 (2.0) 23.8 (3.9) 0.07
Comorbidities: Cardiac
Coronary Artery Disease 619 (46.9) 163 (49.2) 163 (45.5) 156 (51.5) 137 (43.1) 0.79
Atrial Fibrillation/Flutter 689 (52.8) 161 (48.6) 198 (55.0) 168 (54.7) 162 (52.5) 0.98
Ventricular Arrhythmia 617 (9.7) 154 (51.8) 168 (45.9) 155 (50.9) 140 (47.3) 0.90
Comorbidities: Non-Cardiac
Alcohol Abuse 32 (2.0) 12 (2.9) 7 (1.8) 5 (1.2) 8 (2.1) 0.34
Chronic pulmonary disease 233 (18.3) 54 (18.1) 68 (19.8) 56 (17.2) 55 (18.2) 0.97
Coagulopathy 441 (35.4) 102 (32.9) 121 (35.7) 119 (38.0) 99 (35.1) 0.95
Depression 151 (12.0) 37 (12.5) 33 (9.4) 43 (13.2) 38 (12.5) 0.40
Diabetes, uncomplicated 323 (22.9) 85 (24.5) 91 (24.7) 82 (24.1) 65 (19.6) 0.81
Hypertension 571 (43.4) 138 (42.3) 147 (41.7) 163 (55.8) 123 (36.3) 0.20
Liver disease 35 (2.4) 10 (2.9) 11 (2.7) 6 (1.5) 8 (2.5) 0.77
Fluid and electrolyte disorders 836 (65.2) 216 (68.8) 238 (66.6) 201 (63.5) 181 (63.1) 0.89
Obesity 243 (18.1) 67 (20.7) 79 (22.7) 54 (20.7) 43 (14.1) 0.23
Paralysis 30 (2.6) 8 (3.1) 7 (2.3) 10 (4.0) 5 (1.6) 0.14
Peripheral vascular disorders 106 (8.0) 34(11.2) 29 (8.2) 23 (7.0) 20 (6.4) 0.06
Renal failure 620 (48.4) 144 (44.4) 152 (40.7) 168 (54.6) 156 (52.0) 0.12
In-Hospital Events/Procedures
Mechanical Circulatory Support 421 (35.9) 98 (32.6) 84 (24.6) 134 (48.8) 105 (36.7) 0.08
Pre-implant length of stay, median (IQR) 3 (8-14) 6 (2-17) 8 (2-15) 8 (3-15) 8 (4-12) 0.06
Post-implant length of stay, median (IQR) 20 (15-32) 24 (18-34) 19 (14-30) 19 (14-32) 20 (15-29) 0.001
Hospital Characteristics
Large Hospital 1170 (91.1) 248 (79.7) 334 (95.3) 325 (100) 263 (89.4) 0.17
Teaching 1304 (99.3) 317 (97.0) 354 (100) 325 (100) 308 (100) 0.69
Private, Not-profit 1116 (88.8) 262 (79.6) 254 (76.4) 292 (93.4) 308 (100) 0.06
Large Metropolitan Location 1110 (78.7) 251 (71.9) 276 (68.8) 325 (100) 258 (74.7) 0.12
Association with 30-day All-Cause Readmission
Unadjusted Odds Ratio (95% Confidence Interval) -- 0.90 (0.61-1.33) 0.77 (0.51-1.16) 0.86 (0.55-1.34) Reference
Adjusted Odds Ratio (95% Confidence Interval) -- 0.89 (0.67-1.17) 0.81 (0.62-1.06) 0.74 (0.51-1.05) Reference

SD – Standard Deviation, IQR – Interquartile Range

P-value calculated using Rao-Scott Chi-Square test for categorical variables and design-adjusted ANOVA for continuous variables.

Overall, 27% (95% CI 25-30%) of patients were readmitted within 30 days of discharge following LVAD implantation. The 30-day readmission rates were similar across hospital volume quartiles—lowest quartile 26.6% (95% CI 22-32%); second quartile 27% (95% CI 23-34%), third quartile; 25.7% (95% CI 22-32) and highest quartile; 29.9% (95% CI 25-35). In multivariable-adjusted analysis, there was no association between LVAD hospital volume and 30-day readmission rate (Table).

To ensure the robustness of our findings, we performed a sensitivity analysis where we repeated the analysis using different volume cutoffs described in a prior study (5): very low (≤10 LVAD procedures), low (11-30), medium (31-50) and high (≥51). Our findings were similar—the adjusted odds ratio of 30-day readmission for very low volume (vs. high volume) was 0.94 (95% CI 0.67-1.32). We also repeated the analysis treating LVAD hospital volume as a continuous variable, revealing an odds ratio of 1.00 (95% CI 0.99-1.01).

In this nationwide study of LVAD recipients, we found that LVAD hospital volume was not associated with 30-day readmissions following LVAD implantation. Previous studies examining the impact of hospital volume on short-term outcomes after LVAD implantation have focused primarily on in-hospital mortality with conflicting results. Two prior studies using administrative data prior to 2012 found LVAD hospital volume and surgeon volume to be independent predictors of mortality (10, 11). However, a more contemporary analysis of INTERMACS data did not show an association between hospital volume and mortality (6). To our knowledge, this is the first study to examine the association of LVAD hospital volume with 30-day readmissions following LVAD implantation. Our observation that readmission rates were similar across volume quartiles is reassuring, and likely reflects standardized practice patterns which include meticulous blood pressure control, driveline care, and anticoagulation management as well as post-implant follow-up by a multi-disciplinary team. Consequently, outcomes may be less dependent on the surgical experience of a hospital.

Acknowledgements

Sources of Funding:

None.

Disclosures:

Dr. Goyal is supported by the National Institute on Aging grant R03AG056446 and American Heart Association grant 18IPA34170185; and is a recipient of a National Institute on Aging Loan Repayment Plan.

References

  • 1.Agrawal S, Garg L, Shah M, Agarwal M, Patel B, Singh A, et al. Thirty-Day Readmissions After Left Ventricular Assist Device Implantation in the United States: Insights From the Nationwide Readmissions Database. Circulation Heart failure. 2018;11(3):e004628. [DOI] [PubMed] [Google Scholar]
  • 2.Khera S, Kolte D, Gupta T, Goldsweig A, Velagapudi P, Kalra A, et al. Association Between Hospital Volume and 30-Day Readmissions Following Transcatheter Aortic Valve ReplacementHospital Volume and Readmissions After Transcatheter Aortic Valve ReplacementHospital Volume and Readmissions After Transcatheter Aortic Valve Replacement. JAMA Cardiology. 2017;2(7):732–41. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Yeo I, Kim LK, Wong SC, Cheung JW, Itagaki S, Chikwe J, et al. Relation of Hospital Volume With In-Hospital and 90-Day Outcomes After Transcatheter Mitral Valve Repair Using MitraClip. American Journal of Cardiology. 2019;124(1):63–9. [DOI] [PubMed] [Google Scholar]
  • 4.van Walraven C, Austin PC, Jennings A, Quan H, Forster AJ. A Modification of the Elixhauser Comorbidity Measures Into a Point System for Hospital Death Using Administrative Data. Medical Care. 2009;47(6):626–33. [DOI] [PubMed] [Google Scholar]
  • 5.Cowger JA, Stulak JM, Shah P, Dardas TF, Pagani FD, Dunlay SM, et al. Impact of Center Left Ventricular Assist Device Volume on Outcomes After Implantation. An INTERMACS Analysis. 2017;5(10):691–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Brinkley DM, DeNofrio D, Ruthazer R, Vest Amanda R, Kapur Navin K, Couper Gregory S, et al. Outcomes After Continuous-Flow Left Ventricular Assist Device Implantation as Destination Therapy at Transplant Versus Nontransplant Centers. Circulation: Heart Failure. 2018;11(3):e004384. [DOI] [PubMed] [Google Scholar]

RESOURCES