Dosimetric comparison of coplanar and noncoplanar beam arrangements for radiotherapy of patients with lung cancer: A meta‐analysis

Min Ma 1, Wenting Ren 1, Minghui Li 1, Chuanmeng Niu 1, Jianrong Dai 1,
PMCID: PMC8035566  PMID: 33634946

Abstract

Purpose

Radiotherapy plays an important role in the treatment of lung cancer, and both coplanar beam arrangements (CBA) and noncoplanar beam arrangements (NCBA) are adopted in clinic practice. The aim of this study is to answer the question whether NCBA are dosimetrically superior to CBA.

Methods

Search of publications were performed in PubMed, Web of Science, and the Cochran Library till March 2020. The searching terms were as following: ((noncoplanar) or ("non coplanar") or ("4pi") or ("4π")) AND (("lung cancer") or ("lung tumor") or ("lung carcinoma")) AND ((radiotherapy) or ("radiation therapy")). The included studies and extracted data were manually screened. All forest and funnel plots were carried out with RevMan software, and the Egger’s regression asymmetry tests were conducted with STATA software.

Results

Nine studies were included and evaluated in the meta‐analysis and treatment plans were designed with both CBA and NCBA. For the planning target volumes (PTV), D98%, D2%, the conformity index (CI), and the gradient index (GI) had no statistically significant difference. For organs‐at‐risk (OAR), V20 of the whole lung and the maximum dose of the spinal cord were significantly reduced in NCBA plans compared with CBA ones. But V10, V5, and mean dose of the whole lung, the maximum dose of the heart, and the maximum dose of the esophagus exhibited no significant difference when the two types of beam arrangements were compared.

Conclusion

After combining multicenter results, NCBA plans have significant advantages in reducing V20 of the whole lung and max dose of spinal cord.

Keywords: coplanar beam arrangement, lung cancer, meta‐analysis, noncoplanar

1. INTRODUCTION

The incidence and mortality of lung cancer are the highest in a variety of malignancies, and the incidence of lung cancer grows every year. 1 By 2020, approximately 228 820 lung cancer patients are expected to be diagnosed in the United States (US), and 135 720 of these patients may die from the disease. 2 Currently, the preferred treatment for lung cancer is surgery. Moreover, radiotherapy plays a more and more important role in the treatment of lung cancer if the patient is unable to be treated surgically. In particular, stereotactic body radiation therapy (SBRT) is a method that can be used for treating inoperable, nonsmall cell lung cancers (NSCLC) and lung metastases. 3 According to recent studies, 4 , 5 , 6 , 7 , 8 SBRT has exhibited favorable clinical outcomes. To achieve a high local control rate and a low toxicity, SBRT treatment of the lung cancer has been performed on gantry‐mounted linear accelerators (LINACs) using noncoplanar or coplanar three‐dimensional conformal radiation therapy (3DCRT), 9 , 10 intensity modulated radiation therapy (IMRT), 10 , 11 and volumetric modulated arc therapy (VMAT) 12 , 13 , 14 to acquire optimal dose distributions 15 , 16 , 17 , 18 and increase the efficiency of treatment delivery.

Several studies 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 have compared coplanar beam arrangements (CBA) and noncoplanar beam arrangements (NCBA) for the radiotherapy of lung cancer, which is delivered on gantry‐mounted LINACs. However, whether NCBA are superior to CBA remains unclear. Thus, we performed this meta‐analysis to compare CBA and NCBA in terms of D98%, D2%, the conformity index (CI), and the gradient index (GI) of the planning target volume (PTV) and organs‐at‐risk (OAR) sparing, including the whole lung, the spinal cord, the heart, and the esophagus.

2. MATERIAL AND METHODS

2.A. Search strategy

Systematic searches were conducted in PubMed, Web of Science, and the Cochrane Library. The searching terms were as following: ((noncoplanar) or ("non coplanar") or ("4pi") or ("4π")) AND (("lung cancer") or ("lung tumor") or ("lung carcinoma")) AND ((radiotherapy) or ("radiation therapy")). No language restrictions were imposed. Any disagreements or discrepancies were resolved by consensus. The searching strategy of Web of Science was taking as an example: ((noncoplanar) or ("non coplanar") or ("4pi") or ("4π") [theme]) AND (("lung cancer") or ("lung tumor") or ("lung carcinoma") [theme]) AND ((radiotherapy) or ("radiation therapy") [theme]).

2.B. Inclusion and exclusion criteria

A study was included in this meta‐analysis if it fulfilled four predefined criteria: (a) A study was selected if it provides dose information or assessment of lung cancer patients who had been treated with coplanar compared with noncoplanar beams; (b) Coplanar and noncoplanar radiotherapy plans for each patient were designed; (c) Sufficient dosimetric data were contained in the study; and (d) Studies were published up to March 2020.

A study was excluded, even if satisfying the above inclusion criteria, if it (a) investigated clinical trial and clinical outcomes; (b) was not using photon radiotherapy; (c) provided data lacked mean or standard deviation; and (d) was not a scientific paper (e.g., conference abstract, conference proceeding, book, patent).

2.C. Data extraction

Information extracted from each article included: first author, year of publication, sample size, prescribed dose, number of fractions, PTV (D98%, D2%, CI and GI), the whole lung (mean dose, V10, V5, and V20), the spinal cord (maximum dose), the heart (maximum dose), and the esophagus (maximum dose). If VMAT, N‐VMAT, and N‐FFF‐VMAT are emerged in the article, VMAT and N‐VMAT would be chosen. When there is only the maximum dose of PTV, D2% of PTV is replace with the maximum dose. Similarly, when there is only the minimum dose of PTV, D98% of PTV is taken place of the minimum dose.

2.D. Statistical analysis

The meta‐analysis and statistics included forest plots, and publication bias. Visual inspection of the funnel plot as well as the Egger’s regression asymmetry test was applied to assess publication bias. All forest and funnel plots were performed using RevMan (Version 5.3; Cochrane Collaboration, Oxford, UK) and the Egger’s regression asymmetry tests were conducted with STATA software (Version 16.0; Stata Corporation, College Station, TX). Generic inverse variance method 29 was used to calculate the standardized mean difference (SMD). 30 , 31 The heterogeneity of all included studies was evaluated by calculating the I2statistic. 31 A fixed‐effects model was applied when the I2statistic < 50%, indicating that all included studies exhibited homogeneity. 32 Otherwise, a random‐effects model was applied when the I2statistic > 50%. 32 A P < 0.05 was considered as statistically significant. 33 For the Egger test, P > 0.1 was considered as no publication bias. 34

3. RESULTS

3.A. Study selection and features of the included studies

The total numbers of relevant studies recorded during the initial searches from PubMed, Web of Science, and the Cochrane Library were 87, 104, and 5, respectively. After elimination of duplicates and conference abstracts, 99 articles were identified. After the topics and abstracts were read, 66 additional papers were excluded because they were not pertinent to the subject matter. Twenty‐two studies for dosimetric comparisons were also eliminated because 14 studies did not relate to our topics, whereas eight other studies did not record the means or standard deviations. In addition, two studies were excluded because they only compared different noncoplanar radiotherapy techniques. Finally, nine full‐text records were included in the meta‐analysis, and all used SBRT. Flow chart detailing the search strategy and identification of studies was depicted in Fig. 1. The main features of the studies for dosimetric comparison were summarized in Table 1.

Fig. 1.

Fig. 1

Flow chart detailing the search strategy and identification of studies.

Table 1.

Main features of the studies for dosimetric comparison.

Study Type Dose /fr Patients PTV OAR Dose algorithm
Coplanar noncoplanar D98% D2% CI GI Whole lung Spinal cord Heart Esophagus
Fleckenstein 2018 22 NSCLC 60 Gy/5fr 46 46 Yes Yes Mean dose, V10, V5 Monaco, Monte Carlo
Herbert 2013 23 NSCLC 48 Gy/4fr 10 10 Yes Yes Mean dose Max dose Max dose Eclipse, AAA
Ishii 2016 18 NSCLC 70 Gy/10fr 15 15 Yes Yes Yes Mean dose, V20, V10, V5 Max dose Max dose Max dose Eclipse, AAA
Kim 2019 24 NSCLC 60 Gy/4fr 20 20 Yes Yes Yes Yes Mean dose, V20, V10, V5 Max dose Max dose Eclipse, AAA
Marnitz 2002 9 NSCLC 50 Gy/2fr 10 10 Mean dose, V20 Max dose Max dose Helios, conjugate gradient algorithm
Tajaldeen 2019 26 NSCLC 26 Gy/1fr 12 12 Yes Yes Yes Yes V20, V5 Max dose Max dose Max dose Eclipse, AAA
Tajima 2015 27 NSCLC 75 Gy/30fr 21 21 Yes Mean dose, V20, V10, V5 Max dose Max dose Max dose Xio, superposition algorithm
Zhang 2011 14 early stage 50 Gy/5fr 15 15 Yes Yes Mean dose, V20, V5 Pinnacle, DMPO
Ong 2010 13 NSCLC 18 Gy/3fr, 11 Gy/5fr, 7.5 Gy/8fr 18 18 Yes V20, V5 Max dose Eclipse, AAA

Abbreviation: NSCLC = nonsmall cell lung cancer, D98% = dose received by at least 98% volume of the planning target volume, D2% = dose received by at least 2% volume of the planning target volume, CI = the conformity index, GI = the gradient index, OAR = organs‐at‐risk, V5 = volume of lung receiving 5 Gy or more, V10 = volume of lung receiving 10 Gy or more, V20 = volume of lung receiving 20 Gy or more, AAA = anisotropic analytic algorithm, DMPO = direct machine parameters optimization.

3.B. Dosimetric comparisons of coplanar and noncoplanar beam arrangements for the radiotherapy of lung cancer

D98%, D2%, CI and GI of PTV did not show any significant differences between the two types of beam arrangements with mean differences of 0.13 (95% confidence interval (95% CI) [−0.16, 0.42], I2: 2%, P = 0.36) [Fig. 2(a)], 0.29 (95% CI [−0.29, 0.88], I2: 78%, P = 0.33) [Fig. 2(b)]; −0.40 (95% CI [−1.43, 0.63], I2: 88%, P = 0.45) [Fig. 2(c)], and −0.27 (95% CI [−0.64, 0.11], I2: 29%, P = 0.16) [Fig. 2(d)] respectively.

Fig. 2.

Fig. 2

Forest plot of (a) D98%, (b) D2%, (c) CI, and (d) GI of PTV between CBA and NCBA plans.

The whole lung, the spinal cord, the heart, and the esophagus were the four main OARs in the radiotherapy treatment of lung cancer. In the case of the whole lung, the mean dose, V10, and V5 did not contribute to any differences between CBA and NCBA, with a mean difference of −0.10 (95% CI [−0.34, 0.13], I2: 0%, P = 0.39) [Fig. 3(a)], –0.21 (95% CI [−0.49, 0.07], I2: 0%, P = 0.14) [Fig. 3(b)], and −0.10 (95% CI [−0.32, 0.12], I2: 0%, P = 0.38) [Fig. 3(c)], respectively. However, the V20 of the whole lung had significantly decreased for NCBA than CBA for radiotherapy (mean volume difference: −0.25, 95% CI [−0.43, −0.07], I2: 0%, P = 0.02) [Fig. 3(d)]. For the spinal cord, the maximum dose of NCBA was significantly lower than that of CBA for radiotherapy, with a mean maximum dose difference of −0.50 (95% CI [−0.78, −0.22], I2: 34%, P = 0.0004) (Fig. 4). The maximum doses in the heart and the esophagus did not show statistical differences between the two beam arrangements techniques, with mean maximum dose differences of −0.20 (95% CI [−0.52, 0.12], I2: 0%, P = 0.21) (Fig. 5), and −1.43 (95% CI [−3.76, 0.90]; I2: 36%, P = 0.23) (Fig. 6).

Fig. 3.

Fig. 3

Forest plot of (a) mean dose, (b) V10, (c) V5, and (d) V20 of whole lung between CBA and NCBA plans.

Fig. 4.

Fig. 4

Forest plot of maximum dose in spinal cord between CBA and NCBA plans.

Fig. 5.

Fig. 5

Forest plot of maximum dose in heart between CBA and NCBA plans.

Fig. 6.

Fig. 6

Forest plot of maximum dose in esophagus between CBA and NCBA plans.

3.C. Publication bias

The publication bias for the meta‐analysis was difficult to estimate because of the limited number of included studies. The funnel plots seemed to be symmetrical on visual inspection of D98%, GI, V20, and V10 of whole lung (Fig. 7). In addition, Egger’s tests were applied, which demonstrated no publication bias for all the parameters (D98%: P = 0.286, D2%: P = 0.726, CI: P = 0.917, GI: P = 0.771, mean dose of the whole lung: = 0.919, V20 of the whole lung: P = 0.404, V10 of the whole lung: P = 0.219, V5 of the whole lung: P = 0.273, maximum dose of the heart: P = 0.299, maximum dose of the spinal cord: P = 0.995, and maximum dose of the esophagus: P = 0.561, respectively). All funnel plots were exhibited in Fig. 7.

Fig. 7.

Fig. 7

Funnel plots for publication bias of selected meta‐analysis. (a) D98%, (b) D2%, (c) CI, (d) GI, (e) mean dose of the whole lung, (f) V10 of the whole lung, (g) V5 of the whole lung, (h) V20 of the whole lung, (i) maximum dose of spinal cord, (j) maximum dose of heart, (k) maximum dose of esophagus.

4. DISCUSSION

For the target dose in CBA and NCBA plans, there is no significant difference in CI, GI, D98%, and D2%. This shows that the coverage of the target dose between CBA and NCBA plans is similar and will not affect the target dose due to different beam arrangements.

The D98% of PTV is considered as the near‐minimum absorbed dose. 35 The meta‐analysis of the D98% of the PTV has no significant difference (P = 0.36) between CBA and NCBA plans. As can be seen from the table on the left in Fig. 2(a), only Tajaldeen et al. 26 reported that D98% of CBA was higher than that of NCBA. It is known from the included literature that certain beam angles could be limited in order to avoid collisions when we design NCBA plans. 36

The D2% of the PTV is the near‐maximum absorbed dose. 35 The meta‐analysis of the D2% of the PTV (P = 0.33) has no significant difference between CBA and NCBA plans. Judging which technique is more advantageous is difficult. In addition, the result is heterogeneous. Sensitivity or pressure group analyses need to be conducted for exploring the source of heterogeneity. Additional explorations are beyond the purpose of this article.

Conformity index is a complementary tool that defined a score for each treatment plan to allow comparisons of different treatment plans for the same patient. 37 Five articles were included regarding CI. The included studies used the same definition of conformity index. The meta‐analysis of CI has no significant difference (P = 0.45) between CBA and NCBA plans. This may be attributed to the different calculation approaches or to the limited number of articles. From the formula, the closer of the CI value is to 1, the better is the conformity of PTV. 38 Since the CI values in these studies are always greater than 1, the smaller CI indicated better target conformality. In addition, the CI has a higher heterogeneous result because of the small sample size, planning strategies, or optimization algorithm. 39

Gradient index is a measure of steep dose gradient outside the target volume. 38 It is an important index for plan comparison. The meta‐analysis of GI has no significant difference (P = 0.16) between CBA and NCBA plans. Three out of four of studies 14 , 23 , 24 reported that the noncoplanar plans resulted in better GI indices than the coplanar plans for the lung cancer. As can be seen from the table on the left in Fig. 2(d), only Tajaldeen et al. 26 reported that VMAT resulted in the better than noncoplanar IMRT, without considering the confidence interval. It is known from the included literature that the angle separation of the noncoplanar arc is limited when we design NCBA plans. 14

The whole lung is the foremost OAR in lung cancer. The mean dose, V20, V10, and V5, are compared in the cases of NCBA and CBA for radiotherapy treatment. Tajima et al. 27 reported that NCBA improved the plan quality with respect to the whole lung sparing than CBA at the mean dose, V20, V10, and V5. However, Kim et al. 24 suggested that there was no statistical significance reduction between NCBA and CBA about the whole lung sparing. After the meta‐analysis, it is found that only the V20 of the whole lung is significant (P = 0.02). One important dose‐limiting toxicity in lung cancer is radiation pneumonitis, whose occurrence and severity correlates well with V20. 40 The lower the V20, the lower the risk of radiation pneumonitis. 41 , 42 , 43 , 44 Therefore, noncoplanar radiotherapy was found to have lower the risk of radiation pneumonitis than coplanar one.

For the spinal cord, a total of six studies were used for the meta‐analysis. This shows that the maximum dose of the spinal cord was significantly decreased (P = 0.0004) in NCBA plans. With the exception of Marnitz et al. 9 who compared noncoplanar 3DCRT and IMRT, others 13 , 18 , 24 , 26 , 27 reported that noncoplanar radiotherapy was more advantageous than coplanar radiotherapy on spinal cord sparing. Marnitz et al. 9 concluded that IMRT can better spare spinal cord compared with N‐3DCRT, which could be caused by the advanced algorithm of inverse optimization using IMRT. In additional, some articles 45 , 46 , 47 considered that high spinal cord dose could increase the risk of developing metastatic spinal cord compression (MSCC) resulting in disability in mobility and poorer quality of life for patients. Finally, it is concluded based on our analysis that noncoplanar radiotherapy has significant advantages in protecting the spinal cord.

The heart is another important OAR. Because the data number of the same dosimetric parameter is limited, only the maximum dose of the heart was discussed. Five articles were included. The maximum dose of the heart has no significant difference (P = 0.21) in the cases of NCBA and CBA plans. This indicates that the maximum heart dose may be influenced in a complex manner by the planning methods, such as the couch angles and constraints due to target shape and location. In this way, it is difficult to reflect the advantages of noncoplanar radiotherapy in protecting the heart.

As can be seen from the table on the left in Fig. 6, the four included literatures showed that NCBA radiotherapy plans had a lower esophagus maximum dose than CBA ones. No significant difference (P = 0.23) in the maximum dose of esophagus is observed between NCBA and CBA plans. Marnitz et al. 9 demonstrated that 3DCRT was superior to noncoplanar IMRT in esophagus sparing. This could be attributed to the dose escalation in the IMRT plans, but the dose to the esophagus reduced only in two out of 10 patients.

The other dosimetric parameters of the OARs were not subjected to meta‐analyses mainly because the data number was less than four. Hence, the meta‐analysis does not have much relevance. In this study, Fleckenstein et al., 22 Herbert et al., 23 Ishii et al., 18 Kim et al. 24 and Ong et al. 13 all discussed that NCBA plans generally requires more time to deliver the treatment than CBA plans due to the time required for positioning of the couch or involving a large number of beams optimization. 18 , 25 , 48 , 49 The meta‐analysis of treatment time is not performed mainly because only two articles 22 , 23 provided the mean or standard deviation of treatment time. Due to the limited number of studies using noncoplanar treatment methods, the meta‐analysis to only one configuration of treatment planning systems (TPS) and calculation algorithms was restricted.

However, there exists some problems in NCBA radiotherapy such as: (a) collision between the patient (or couch) and the gantry head, (b) longer treatment time than that of the coplanar radiotherapy plans, (c) potentially large patient setup uncertainty by couch rotation, (d) hardware challenge of delivery accuracy and automation, (e) the lack of mature beam orientation optimization programs operating in the noncoplanar space. These limitations lead to restrictions on the design of NCBA plans.

5. CONCLUSION

After combining multicenter results, NCBA plans have significant advantages in reducing V20 of the whole lung and max dose of spinal cord. It is suggested to consider NCBA when CBA cannot meet clinical requirements.

ACKNOWLEDGMENTS

This work is supported by the National Natural Science Foundation of China (Grant No. 11875320). Author’s contributions: Min Ma: study conception, design, data acquisition, do the meta‐analysis, wrote paper; Wenting Ren: drafted the manuscript; Minghui Li: data processed and drafted the manuscript; Chuanmeng Niu: data processed and drafted the manuscript; Jianrong Dai: drafted the manuscript and supervised the study; and all authors revised it critically for important intellectual content. All have given final approval.

REFERENCES

  • 1. Kim S, Tseng T‐C. Off‐target‐isocentric approach in non‐coplanar volumetric modulated arc therapy (VMAT) planning for lung SBRT treatments. J Radiosurg SBRT. 2015;3:215–224. [PMC free article] [PubMed] [Google Scholar]
  • 2. Tarver T. Cancer facts & figures 2018. American cancer society (ACS) Atlanta, GA: American Cancer Society, 2018 76 p., pdf. Available from. Taylor & Francis 2018.
  • 3. Grutters JPC, Kessels AGH, Pijls‐Johannesma M, et al. Comparison of the effectiveness of radiotherapy with photons, protons and carbon‐ions for non‐small cell lung cancer: aa meta‐analysis. Radiother Oncol. 2010;95:32–40. [DOI] [PubMed] [Google Scholar]
  • 4. Choi JI. Medically inoperable stage I non‐small cell lung cancer: best practices and long‐term outcomes. Transl Lung Cancer Res. 2019;8:32–47. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Mix M, Tanny S, Nsouli T, et al. Outcomes following stereotactic body radiotherapy with intensity‐modulated therapy versus three‐dimensional conformal radiotherapy in early stage non‐small cell lung cancer. Lung Cancer (Auckl). 2019;10:151–159. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Parisi G, Ceschia T, Parisi A. Stereotactic body radiation therapy and surgery for early lung cancer "two sides of the same coin". J Thorac Dis. 2019;11:S271–S274. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Rosenzweig K. Stereotactic body radiation therapy as an alternative to surgery in early‐stage non‐small‐cell lung cancer. Oncology (Williston Park). 2017;31:492–498. [PubMed] [Google Scholar]
  • 8. Schneider BJ, Daly ME, Kennedy EB, et al. Stereotactic body radiotherapy for early‐stage non‐small‐cell lung cancer: American Society of Clinical Oncology Endorsement of the American Society for radiation oncology evidence‐based guideline. J Clin Oncol. 2018;36:710–719. [DOI] [PubMed] [Google Scholar]
  • 9. Marnitz S, Stuschke M, Bohsung J, et al. Intraindividual comparison of conventional three‐dimensional radiotherapy and intensity modulated radiotherapy in the therapy of locally advanced non‐small cell lung cancer a planning study. Strahlenther Onkol. 2002;178:651–658. [DOI] [PubMed] [Google Scholar]
  • 10. Derycke S, Van Duyse B, De Gersem W, et al. non‐coplanar beam intensity modulation allows large dose escalation in stage III lung cancer. Radiother Oncol. 1997;45:253–261. [DOI] [PubMed] [Google Scholar]
  • 11. Chapet O, Khodri M, Jalade P, et al. Potential benefits of using non coplanar field and intensity modulated radiation therapy to preserve the heart in irradiation of lung tumors in the middle and lower lobes. Radiother Oncol. 2006;80:333–340. [DOI] [PubMed] [Google Scholar]
  • 12. Verbakel WFAR, Senan S, Cuijpers JP, et al. Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity‐modulated arcs. Radiother Oncol. 2009;93:122–124. [DOI] [PubMed] [Google Scholar]
  • 13. Ong CL, Verbakel WFAR, Cuijpers JP, et al. Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques. Radiother Oncol. 2010;97:437–442. [DOI] [PubMed] [Google Scholar]
  • 14. Zhang GG, Ku L, Dilling TJ, et al. Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique. Radiat Oncol. 2011;6:152. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Dong P, Lee P, Ruan D, et al. 4 pi noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors. Int J Radiat Oncol Biol Phys. 2013;86:407–413. [DOI] [PubMed] [Google Scholar]
  • 16. Fitzgerald R, Owen R, Hargrave C, et al. A comparison of three different VMAT techniques for the delivery of lung stereotactic ablative radiation therapy. J Med Radiat Sci. 2016;63:23–30. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Fitzgerald R, Owen R, Hargrave C, et al. A comparison of noncoplanar three‐dimensional conformal radiation therapy, intensity modulated radiation therapy, and volumetric modulated radiation therapy for the delivery of stereotactic ablative radiation therapy to peripheral lung cancer. J Med Imaging Radiat Sci. 2017;48:360–369. [DOI] [PubMed] [Google Scholar]
  • 18. Ishii K, Okada W, Ogino R, et al. A treatment‐planning comparison of three beam arrangement strategies for stereotactic body radiation therapy for centrally located lung tumors using volumetric‐modulated arc therapy. J Radiat Res. 2016;57:273–279. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Brock J, Bedford J, Partridge M, et al. Optimising stereotactic body radiotherapy for non‐small cell lung cancer with volumetric intensity‐modulated arc therapy‐a planning study. Clin Oncol (R Coll Radiol). 2012;24:68–75. [DOI] [PubMed] [Google Scholar]
  • 20. Dong P, Lee P, Ruan D, et al. 4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors. Int J Radiat Oncol Biol Phys. 2013;86:407–413. [DOI] [PubMed] [Google Scholar]
  • 21. Fitzgerald R, Owen R, Barry T, et al. The effect of beam arrangements and the impact of non‐coplanar beams on the treatment planning of stereotactic ablative radiation therapy for early stage lungcancer. J Med Radiat Sci. 2016;63:31–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Fleckenstein J, Boda‐Heggemann J, Siebenlist K, et al. noncoplanar VMAT combined with non‐uniform dose prescription markedly reduces lung dose in breath‐hold lung SBRT. Strahlenther Onkol. 2018;194:815–823. [DOI] [PubMed] [Google Scholar]
  • 23. Herbert C, Kwa W, Nakano S, et al. Stereotactic body radiotherapy: volumetric modulated arc therapy versus 3D non‐coplanar conformal radiotherapy for the treatment of early stage lung cancer. Technol Cancer Res Treatm. 2013;12:511–516. [DOI] [PubMed] [Google Scholar]
  • 24. Kim S‐T, An HJ, Kim J‐I, et al. non‐coplanar VMAT plans for lung SABR to reduce dose to the heart: a planning study. Br J Radiol. 2020;93:20190596. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Saglam Y, Bolukbasi Y, Alpan V, et al. Hybrid arc could combine the benefits of IMRT and VMAT to deliver a fast, conformal, homogeneous treatment in non‐small cell lung cancer without limitations of low dose bath: a planning study. Uhod‐Uluslararasi Hematoloji‐Onkoloji Dergisi. 2017;27:161–170. [Google Scholar]
  • 26. Tajaldeen A, Ramachandran P, Alghamdi S, et al. On the use of AAA and AcurosXB algorithms for three different stereotactic ablative body radiotherapy (SABR) techniques: volumetric modulated arc therapy (VMAT), intensity modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3D‐CRT). Rep Pract Oncol Radiother. 2019;24:399–408. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Tajima Y, Nakayama H, Itonaga T, et al. Dosimetric evaluation of compensator intensity modulation‐based stereotactic body radiotherapy for Stage I non‐small‐cell lung cancer. Br J Radiol. 2015;88:20150122. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Yang W, Jones R, Lu W, et al. Feasibility of non‐coplanar tomotherapy for lung cancer stereotactic body radiation therapy. Technol Cancer Res Treatm. 2011;10:307–315. [DOI] [PubMed] [Google Scholar]
  • 29. Anli X. Application of generic inverse variance method in meta‐analysis. J Math Med. 2012;1:5. [Google Scholar]
  • 30. Borenstein M. Computing Effect Sizes for Meta‐Analysis. Hoboken, NJ: Wiley‐Blackwell; 2013. [Google Scholar]
  • 31. Borenstein M, Hedges LV, Higgins JP, et al. Introduction to Meta‐Analysis. Hoboken, NJ: John Wiley & Sons; 2011. [Google Scholar]
  • 32. Huedo‐Medina TB, Sánchez‐Meca J, Marín‐Martínez F, et al. Assessing heterogeneity in meta‐analysis: Q statistic or I2 index? Psychol Methods. 2006;11:193. [DOI] [PubMed] [Google Scholar]
  • 33. Wasserstein RL, Lazar NA. The ASA Statement on p‐Values: Context, Process, and Purpose. Milton: Taylor & Francis; 2016. [Google Scholar]
  • 34. Higgins J, Thompson S, Deeks J, et al. Statistical heterogeneity in systematic reviews of clinical trials: a critical appraisal of guidelines and practice. J Health Serv Res Policy. 2002;7:51–61. [DOI] [PubMed] [Google Scholar]
  • 35. Vol I. Prescribing, Recording, and Reporting Photon‐Beam Intensity‐Modulated Radiation Therapy (IMRT): Contents; 2010;10(1):NP.
  • 36. Smyth G, Bamber JC, Evans PM, et al. Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy. Phys Med Biol. 2013;58:8163. [DOI] [PubMed] [Google Scholar]
  • 37. Feuvret L, Noel G, Mazeron JJ, et al. Conformity index: a review. Int J Radiat Oncol Biol Phys. 2006;64:333–342. [DOI] [PubMed] [Google Scholar]
  • 38. Patel G, Mandal A, Choudhary S, et al. Plan evaluation indices: a journey of evolution. Rep Pract Oncol Radiother. 2020;25:336–344. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Ren W, Sun C, Lu N, et al. Dosimetric comparison of intensity‐modulated radiotherapy and volumetric‐modulated arc radiotherapy in patients with prostate cancer: a meta‐analysis. J Appl Clin Med Phys. 2016;17:254–262. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40. Kataria T, Gupta D, Bisht SS, et al. Adaptive radiotherapy in lung cancer: dosimetric benefits and clinical outcome. Br J Radiol. 2014;87:20130643. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41. Barriger RB, Forquer JA, Brabham JG, et al, A dose‐volume analysis of radiation pneumonitis in non‐small cell lung cancer patients treated with stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys. 2012;82:457–462. [DOI] [PubMed] [Google Scholar]
  • 42. Claude L, Perol D, Ginestet C, et al. A prospective study on radiation pneumonitis following conformal radiation therapy in non‐small‐cell lung cancer: clinical and dosimetric factors analysis. Radiother Oncol. 2004;71:175–181. [DOI] [PubMed] [Google Scholar]
  • 43. Matsuo Y, Shibuya K, Nakamura M, et al. Dose–volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer. Int J Radiat Oncol Biol Phys. 2012;83:e545–e549. [DOI] [PubMed] [Google Scholar]
  • 44. Tsujino K, Hirota S, Endo M, et al. Predictive value of dose‐volume histogram parameters for predicting radiation pneumonitis after concurrent chemoradiation for lung cancer. Int J Radiat Oncol Biol Phys. 2003;55:110–115. [DOI] [PubMed] [Google Scholar]
  • 45. Conill C, Marruecos J, Verger E, et al. Clinical outcome in patients with intramedullary spinal cord metastases from lung cancer. Clin Transl Oncol. 2007;9:172–176. [DOI] [PubMed] [Google Scholar]
  • 46. Rades D, Douglas S, Veninga T, et al. Metastatic spinal cord compression in non‐small cell lung cancer patients. Prognostic factors in a series of 356 patients. Strahlenther Onkol. 2012;188:472–476. [DOI] [PubMed] [Google Scholar]
  • 47. Tsuya A, Kurata T, Tamura K, et al. Skeletal metastases in non‐small cell lung cancer: a retrospective study. Lung Cancer. 2007;57:229–232. [DOI] [PubMed] [Google Scholar]
  • 48. Aly MMOM, Glatting G, Jahnke L, et al. Comparison of breast simultaneous integrated boost (SIB) radiotherapy techniques. Radiation Oncology. 2015;10:139. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Tran A, Woods K, Nguyen D, et al. Predicting liver SBRT eligibility and plan quality for VMAT and 4π plans. Radiat Oncol. 2017;12:70. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Applied Clinical Medical Physics are provided here courtesy of Wiley

RESOURCES