Video 1.
Ventilator modes and breath types.
As coronavirus disease (COVID-19) has rapidly evolved into a pandemic, many physicians without prior critical care training are being called upon to help manage severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)–infected patients who develop respiratory failure and require mechanical ventilation. This video is intended to provide a brief and simplified approach to mechanical ventilation for nonintensivists with an overview of major ventilator modes and breath types. For acutely ill patients, the most commonly used mode is the Assist Control (AC) mode. Therefore, we primarily focus on the AC mode in this video. The AC mode requires the clinician to set the FiO2, the positive end-expiratory pressure (PEEP), and the respiratory rate. The patient is able to breathe above, but not below, the set respiratory rate. In addition to selecting the above parameters, a breath type, most commonly either volume control (VC) or pressure control (PC), must also be chosen. In VC, the tidal volume (Vt) is directly selected by the clinician. In PC, the clinician chooses a pressure level above PEEP and the Vt is determined indirectly. As there are advantages and disadvantages for both VC and PC, one is not intrinsically better than the other and the breath type selected is typically dictated by institutional preferences. Whether the clinician uses VC or PC, it is important that the set Vt (in case of VC) or the resulting Vt (in case of PC) is 4–8 ml/kg of predicted body weight.
Supplementary Material
Footnotes
Author disclosures are available with the text of this article at www.atsjournals.org.
RECOMMENDED READING
- Hess DR, Kacmarek RM. Essentials of mechanical ventilation, 3rd ed. New York: McGraw-Hill Education; 2014. [Google Scholar]
- Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301–1308. doi: 10.1056/NEJM200005043421801. [DOI] [PubMed] [Google Scholar]
- Esteban A, Anzueto A, Alía I, Gordo F, Apezteguía C, Pálizas F, et al. How is mechanical ventilation employed in the intensive care unit? An international utilization review. Am J Respir Crit Care Med. 2000;161:1450–1458. doi: 10.1164/ajrccm.161.5.9902018. [DOI] [PubMed] [Google Scholar]
- Acho M, Lee AC, Lee BW. Ventilators for non-intensivists: basic ventilator parameters. ATS Scholar. 2020;1:194. doi: 10.34197/ats-scholar.2020-0041VO. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
