Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2021 Apr 15.
Published in final edited form as: Neuroimage. 2021 Jan 14;230:117746. doi: 10.1016/j.neuroimage.2021.117746

Distributed source modeling of intracranial stereoelectro-encephalographic measurements

Fa-Hsuan Lin 1,2,3, Hsin-Ju Lee 1,2, Jyrki Ahveninen 4, Iiro P Jääskeläinen 3,5, Hsiang-Yu Yu 6,7, Cheng-Chia Lee 7,8, Chien-Chen Chou 6,7, Wen-Jui Kuo 9
PMCID: PMC8044004  NIHMSID: NIHMS1662933  PMID: 33454414

Abstract

Intracranial stereoelectroencephalography (sEEG) provides unsurpassed sensitivity and specificity for human neurophysiology. However, functional mapping of brain functions has been limited because the implantations have sparse coverage and differ greatly across individuals. Here, we developed a distributed, anatomically realistic sEEG source-modeling approach for within- and between-subject analyses. In addition to intracranial event-related potentials (iERP), we estimated the sources of high broadband gamma activity (HBBG), a putative correlate of local neural firing. Our novel approach accounted for a significant portion of the variance of the sEEG measurements in leave-one-out cross-validation. After logarithmic transformations, the sensitivity and signal-to-noise ratio were linearly inversely related to the minimal distance between the brain location and electrode contacts (slopeу ≈−3.6). The signa-to-noise ratio and sensitivity in the thalamus and brain stem were comparable to those locations at the vicinity of electrode contact implantation. The HGGB source estimates were remarkably consistent with analyses of intracranial-contact data. In conclusion, distributed sEEG source modeling provides a powerful neuroimaging tool, which facilitates anatomically-normalized functional mapping of human brain using both iERP and HBBG data.

Keywords: MNE, invasive, dynamic statistical parametric maps, L2-norm, cross-validation, thalamus, brainstem

Introduction

Stereoelectroencephalography (sEEG) detects the neural activity by measuring the electric potentials recorded from electrodes placed inside the brain. Different from electroencephalography (EEG) and magnetoencephalography (MEG), where the neurophysiological signals are measured extracranially, the intracranial recording allows sEEG to provide unprecedented sensitivity to detect local neural currents (Buzsaki et al., 2012). In addition to being used to localize epileptogenic zones (Bartolomei et al., 2017; Serletis et al., 2014), sEEG has also been used for high-level cognitive function studies in epilepsy patients (Piai et al., 2016; Tang et al., 2017; Zheng et al., 2017). While the practical procedure for localizing the electrodes and the associated data analysis has been reported (Stolk et al., 2018), a systematic way to combine sEEG data from different patients to summarize effects observed from discrete sampling loci is still lacking. This difficulty is the consequence of optimizing electrode locations based on individual patients’ medical history, imaging data, and vasculature (Cardinale et al., 2013; De Momi et al., 2013; Gonzalez-Martinez et al., 2014).

One way to address this challenge is to model the spatial distribution of neural currents based on sEEG data in each patient. In EEG and MEG studies, distributed source modeling (Hamalainen and Ilmoniemi, 1994) estimates a spatial distribution of neural current consistent with the measurements over a defined “source space” which is typically over the cortical surfaces, because MEG and EEG are most sensitive to superficial sources (Goldenholz et al., 2009). Individually estimated neural current distributions can be spatially registered to a common coordinate system to derive group-level inferences. This framework has been extensively used in MEG and EEG data analysis (Lin et al., 2006), but a workable solution for anatomically realistic source modeling of sEEG data has been lacking. Methods of modeling the source of sEEG using discrete equivalent current dipoles has been reported (Alhilani et al., 2020; Cam et al., 2017; Caune et al., 2013; Caune et al., 2014). While distributed source modeling has been used in the analysis of electrocorticography (ECoG) (Pascarella et al., 2016; Pistohl et al., 2012; Ramantani et al., 2013; Wang et al., 2019; Zhang et al., 2018), how this method can be used to analyze sEEG data has not been systematically studied. The few pioneering studies published so far have used simple, spherical one-layer head conductivity models (Yvert et al., 2005) or simulations that consider the head and the brain as an infinitely homogeneous model (Hosseini et al., 2018). However, estimating the source of sEEG data using an anatomically realistic head model and empirical measurements and combining the modeling results across patients remains unexplored. A comprehensive description of the procedure and a quantitative evaluation of the performance will have broad impact in bringing this tool in the neuroimaging community.

One of the most interesting sEEG phenomena is high-frequency (> 50 Hz) broadband gamma activity (HBBG). In contrast to large-scale neural oscillations visible also to scalp EEG and MEG, HBBG is believed to reflect “non-oscillatory” broadband signals, which not only reveal high-frequency synaptic effects but also provide a direct correlate of local spiking activity (Manning et al., 2009; Miller, 2010; Ray and Maunsell, 2011). In non-invasive recordings, sensory responses at comparable frequencies are typically much briefer and/or weaker than the sustained HBBG observable in intracranial recordings (Cervenka et al., 2011; Iivanainen et al., 2020). Measurements of HBBG could thus offer an opportunity for much more detailed neurophysiological inferences than those based on iERP or oscillatory local field potentials (LFP) alone (Parvizi and Kastner, 2018). What makes the HBBG specifically interesting from a source modeling perspective is that these signals do not seem to spread far from their neural site of origin. However, no previous study has, to our knowledge, examined HBBG using sEEG source modeling analyses.

Here we report a comprehensive workflow to allow for the distributed modeling of neural currents, including both iERP and HBBG patterns, using sEEG with electrode locations optimized for individual patients with realistic head models. The spatial distributions of neural currents were estimated by the MNE (Hämäläinen and Ilmoniemi, 1984). Importantly, we quantitatively studied three issues related to the modeling. First, we depicted and calculated spatial distributions of sensitivity and SNR of sEEG. Then, based on empirical sEEG measurements, we used a cross-validation procedure to evaluate how much information can be estimated by the distributed source modeling. Third, considering patient’s safety and the access to imaging resources, different types of data (CT and/or MRI) are used in identifying the locations of electrode contacts. We quantified how the variability in the estimated locations of electrode contacts affect the spatiotemporal characteristics of the estimated neural currents. This distributed source modeling framework and performance assessment will make it possible to use sEEG measurements for functional mapping of human brain at the group level and advance using sEEG for neuroscientific inferences from patient groups.

Methods

Participants

This study was approved by the Institute Review Board of National Yang Ming University and Taipei Veteran General Hospital. Ten medically refractory epilepsy patients (age: 21 – 45; nine female) gave written informed consent before participating in this study. Two patients were excluded for the analysis because a large portion of the brain was resected in previous surgeries. The number of the implanted electrode contacts and the hemisphere with electrodes, together with the patient’s demographic information, are listed in Table 1.

Table 1:

Demographic, medical, and surgical information for patients.

Patient # Contacts # Contacts in the gray matter # Contacts in the white matter Epilepsy diagnosis
Whole brain Left hemi. Right hemi. Included for analysis At the auditory cortex Left hemi. Right hemi. Left hemi. Right hemi.
s026 102 102 0 69 1 (T2) 20 0 49 0 Left TLE
s027 116 116 0 104 4 (T2–5) 46 0 61 0 Left TLE
s031 112 0 112 95 2 (T3–4) 0 39 0 56 Right temporal PNH and right frontal opercular PMG
s032 92 92 0 67 3(E4–6) 25 0 42 0 Left TLE
s033 98 98 0 76 6 (T1–6) 28 0 48 0 Left TLE
s034 104 0 104 100 4 (T2–3, Y1–2) 0 33 0 67 Right frontal and temporal schizencephaly
s036 78 0 78 59 3 (Y6–8) 0 17 0 42 Right TLE
s041 80 56 24 70 1 (T2) 15 16 32 7 Right TLE
max. 116
min. 78
average 96
standard deviation 14

TLE: temporal lobe epilepsy, PNH: periventricular nodular heterotopia, PMG: polymicrogyria. M: male; F: female.

Experiment design

Two runs of data were collected from each patient. Each run lasted for six minutes. Within each run, fifty trials of auditory stimuli, including 45 trials of white noise (equal power between 20 Hz and 10,000 Hz; 0.3 s duration) and five trials of pure tone (440 Hz; 0.3 s duration), were randomly presented. The minimum and the average inter-stimulus intervals were 1.2 s and 2.0 s, respectively. Patients were instructed to press a button when hearing a pure tone while ignoring the white noise stimuli. In this study, we only calculated the responses evoked by the white noise in order to avoid confounds related to motor responses. Auditory stimuli were delivered binaurally via insert earphones (Model S14, Sensimetrics, Gloucester, MA, USA) using E-Prime (Psychology Software Tools, Sharpsburg, PA, USA).

sEEG recording

The placement of the electrode was solely based on the patient’s benefit in identifying epileptogenic zones. Each patient was implanted with 8 or 10 electrodes, whose contacts were mostly distributed between bilateral temporal lobes. Each electrode (0.3 mm diameter and spacing between contact centers 5 mm; Ad-Tech, Racine, WI, USA) had 6 or 8 contacts. sEEG data were sampled at 2,048 Hz with an electrode at FPz as the reference (Cam et al., 2017; Caune et al., 2014; Jonas et al., 2014; Jonas et al., 2016; Koessler et al., 2015; Mittal et al., 2016; Rikir et al., 2014).

MRI acquisitions

T1-weighted MRI was collected before and after the surgery for electrode implantation on 3T MRI scanners (Skyra, SIEMENS, Erlangen, Germany; Discovery MR750, General Electric, Milwuakee, WI, USA). The imaging parameters were the same in two acquisitions: MPRAGE sequence, TR/TI/TE/flip = 2530 ms/1100 ms/3.49 ms/7°, partition thickness = 1.33 mm, matrix = 256 × 256, 128 partitions, FOV = 21 cm × 21 cm. Two sets of MRIs were acquired for each patient before and after electrode implantation.

CT acquisitions

Two patients were acquired with CT after electrode implantation. CT images were used to guide the identification of electrode contact locations using 3D slicer (Narizzano et al., 2017). Parameters used in the CT acquisition were 64 slices, rotation duration of 1 second with coverage of 16 cm per rotation, 60-kW generator (512 × 512 matrix), 120 kV, 301 mAs, and axial slice thickness of 1 mm.

Data analysis

All pre-processing steps were performed by using the EEGLAB toolbox (version 14.1.0; http://sccn.ucsd.edu/eeglab/) under the Matlab (MathWorks, Natick, MA) environment. Each recording data set was systematically screened for epileptic activities or poor signal quality by visual inspection. Electrode contacts that generated consistently noisy measurements or at epileptic lesion sites were discarded from the analysis. SEEG waveforms showing epileptiform activity were removed when cropping data into trials. SEEG waveforms were notch filtered at 60 Hz to reduce power line artifacts. Linear trends in data trials were estimated and then detrended. Eye-movement related artifacts were detected and removed by Independent Component Analysis (ICA). Briefly, we analyzed the scalp EEG taken concurrently with SEEG. Both scalp EEG and SEEG signals were separately decomposed by ICA using the Joint Approximation Diagonalisation of Eigen matrices algorithm. The independent component from the scalp EEG showing the largest voltage deflections with a frontal topography in the scalp map was taken as the oculomotor artifact component, which was used to correlate with independent components from the SEEG data. The independent component of SEEG showing the highest correlation was removed. SEEG recording was then segmented into epochs of 1200 ms duration with a 200-ms pre-stimulus baseline and a 1000-ms post-stimulus interval. Each auditory stimulus onset was taken as the time zero of each epoch. SEEG epochs were pre-stimulus baseline corrected by removing the average of the data in the baseline interval. Epochs with SEEG data at any time instant exceeding six standard deviations from the epoch average were discarded. Finally, the evoked responses were averaged across epochs.

The first step of sEEG source analysis was to identify the location of electrode contacts in the individual’s brain. Specifically, in the post-surgery MRI, there were discrete dark image voxel clusters caused by the susceptibility artifact for each electrode contact. These dark image voxels clusters were used to identify the locations of contacts. We developed an in-house software in Matlab (version 2019b, MathWorks, Natick, MA, USA) with a graphical user interface to facilitate this process. Specifically, after manually specifying the distance between neighboring contacts and the number of contacts on an electrode, an electrode was moved around the whole brain such that contact locations matched dark image voxel clusters in the post-surgery MRI. Upon completing the manual identification of electrode locations, contact locations were further optimized by allowing minor translation (±10 mm) and rotation (±2 degrees) by minimizing the sum of squares of image voxel values at all contact locations and their neighboring 26 image voxels within a 3-by-3-by-3 image voxel cubic in the post-surgery MRI using the patternsearch function in MATLAB.

Identified electrode contact locations were registered to pre-surgery MRI, which was used to build Boundary Element Models (BEM’s) required for the lead field calculation and to define locations of potential neural current sources. In the construction of BEM’s the inner-skull, out-skull, and outer-scalp surfaces were automatically created by FreeSurfer (http://surfer.nmr.mgh.harvard.edu) based on the pre-surgery MRI. We did not use the post-surgery MRI for BEM construction because of the concern on the susceptibility artifact caused by electrode contacts and surgery wounds. The cortical source space for each patient was created at the gray matter and white matter boundary with approximately 5-mm separation between neighboring source locations. In addition, we also had a sub-cortical source space, including brain stem, thalamus, caudate, putamen, hippocampus, amygdala, accumbens areas, and substancia nigra. These sub-cortical areas were automatically segmented from T1-weighted MRI (Fischl et al., 2002). At each source location, we had three orthogonal neural current dipoles in +x, +y, and +z directions. The current source space, including both sources at cortical and sub-cortical areas, electrode contacts, and three surfaces of inner-skull, out-skull, and out-scalp from a representative patient are shown in Figure 1 (A). With defined source space, electrode contact locations, and skull as well as scalp boundaries, the lead fields were calculated by the OpenMEEG package (https://openmeeg.github.io/) (Gramfort et al., 2010; Kybic et al., 2005). The relative conductivity values for air, scalp, brain parenchyma, and skull were 0, 1, 1, and 0.0125, respectively.

Figure 1.

Figure 1.

Electrodes, brain models, and the estimated group-averaged neural current distributions and dynamics elicited by the auditory stimulus. (A) An illustration of the source space (green dots) including cortical and sub-cortical brain areas, locations of the electrode contacts (blue dots), and three anatomical boundaries (inner skull, outer skull, and outer scalp) for the lead field calculation using Boundary Element Model on a representative patient. (B) Locations of all electrode contacts (blue dots) depicted over a template brain volume (MNI305) in the left (left column) and right (right column) hemisphere. A: anterior. P: posterior. L: left. R: right. (C) Current distributions overlaid on inflated brain models (top row) and brain structural images at three orthogonal slices (bottom row) at 120 ms after the auditory stimulus, and waveforms at the auditory cortex (middle row). The left and right columns correspond to the results from patients with electrodes implanted at left and right hemispheres, respectively. The average and the standard deviation of the significance time course within the auditory cortex determined from all patients are shown in the middle row.

The measured sEEG data and the neural current sources at time t were related to each other by

y(t)=Ax(t)+n(t), [1]

where y(t) denoted the collection of sEEG data across electrode contacts, x(t) denoted the neural current strength, and n(t) denoted the contaminating noise. In this study, we excluded the electrode contacts potentially related to epileptic activity when we created y(t). Note that x(t) had 3xm elements to describe the neural currents in three orthogonal directions at m brain locations. A was the lead field matrix. Specifically, for a unit current dipole source at location r’ in the +x, +y, or +z direction, the electric potentials measured at all electrode contacts were

a(r)=[ax(r),ay(r),az(r)]. [2]

Assembling a(r’) across all possible current dipole source locations created the lead field matrix A.

A=[a(r1),a(r2),,a(rk)],k=1,,d. [3]

where d denotes the total number of current dipole source locations.

To estimate x(t) using the MNE, we had

xMNE(t)=RAT(ARAT+λC)1y(t), [4]

where C was the noise covariance matrix

C=n(t)nT(t). [5]

The operator 〈·〉 takes the ensemble average across realizations. In practice, C was estimated from y(t) during the pre-stimulus interval (from −200 ms to 0) with data concatenated across trials. The regularization λ tuned the balance between the strength of the estimated neural current strength and the discrepancy between the modeled and measured data. We chose λ = 10 in this study as suggested by a previous MEG study (Lin et al., 2006).

The spatial distribution of estimated neural currents at each time instant from each patient was then spatially registered to an arbitrarily selected subject. Here we chose the subject “fsaverage” in the FreeSurfer library as the target subject. This registration was done via a spherical coordinate system (Fischl et al., 1999). The neural currents were averaged across patients for each condition separately. The significance of neural current distribution was estimated by calculating the ratio between the instantaneous value and the standard deviation of the baseline interval at each source location after subtracting the mean of the estimates in the pre-stimulus interval. These ratios constituted the dynamic statistical parametric maps (dSPM) and were reported to follow a t-like distribution with extremely large degrees of freedom (Dale et al., 2000). The uncorrected p values were calculated by taking dSPM values as Z scores. We corrected the inflation of type-I error in multiple comparison by Bonferroni correction with the threshold of the corrected p <10−4.

We quantified the spatiotemporal distribution of neural HBBG activity in the frequency domain. Specifically, after obtaining xMNE(t) for each trial of stimulus, a Morlet wavelet function was applied to xMNE(t) to extract frequency-specific HGGB signal at the central frequency f. The frequency selectivity was controlled by using five cycles of waveform. We used this narrow-band Morlet wavelet filtering to verify, at higher spectral resolution, that the HBBG was indeed distributed broadly across the spectrum. In this study, we specifically focused on the putative “non-oscillatory” HBBG between 60 Hz and 140 Hz. After the Morlet wavelet filtering, we took the absolute values of the frequency specific HBBG waveforms. At each brain location, we calculated the root of the sum of squares (RSS) of these wavelet-filtered waveforms of three directional components. Then, we averaged RSS of the frequency-specific wavelet-filtered waveforms across trials. The average waveform was then normalized to the average of the pre-stimulus baseline interval. We took the 10-based logarithm of the normalized average waveform as the spatiotemporal map of HBBG at frequency f for each patient. Similar to the group dSPM, these maps were combined across patients by averaging, subtracting the mean of the average, and dividing the standard deviation in the pre-stimulus baseline interval.

These calculations were validated by examining the correspondence of the HBBG between the source modeling from a group of patients and measurements from implanted electrodes. Specifically, we found patients with electrodes implanted at both the left superior temporal gyrus (STG) and inferior frontal gyrus (IFG). The HBBG was estimated by the source modeling of measurements from all patients except the chosen one. Then, HBBG from the dSPM were compared with the results from electrodes close to the left STG and IFG.

Sensitivity and signal-to-noise ratio evaluation

With a given distribution of implanted electrodes and a set of current dipole source locations, we defined the sensitivity for a current dipole source at location r’ as

s(r)=ax2(r)+ay2(r)+az2(r). [6]

A map of s(r’) across current dipole source locations quantitatively depicted locations in the brain most sensitive to a particular set of implanted electrodes.

The signal-to-noise (SNR) at a specific location in the brain was derived from the “whitened” lead field matrix A. We used Singular Value Decomposition on the noise covariance matrix C to obtain a whitening matrix, which was then used to remove the correlation among lead fields and to normalize the sensitivity.

C=UΛUTC-1/2=UΛ-1/2 [7]
Aw=kC1/2A [8]
SNR(r)=aw,x2(r)+aw,y2(r)+aw,z2(r), [9]

where aw,x(r’), aw,y(r’), and aw,z(r’) were columns of Aw corresponding to the location r’ with lead fields in the x-, y-, and, z-direction, respectively. k denotes a scaling factor. Because the lead field matrix A was calculated based on both empirical MRI data and electromagnetic theory to describe the anatomical head as well as brain shapes and the mapping between a current source at an observation site, respectively. The noise covariance C was derived from empirical data, there was no information regarding the relative contribution from both terms. Thus, we arbitrarily chose k =1 in this study. The interpretation of the SNR should be careful considering the possible strength of the neural current and the noise level in different measurement conditions.

Cross-validation

We used cross-validation to evaluate the accuracy of source modeling. Specifically, in a patient, the sEEG data at one contact were left-out, whereas a part of the remaining contacts was used for source modeling. The estimated sources were then used to predict the measurement at the left-out electrode contact by multiplying its lead field matrix and the estimated neural current distribution. Such synthetic data were compared with the actual measurement at the left-out contact. Each contact was taken as the left-out contact in each analysis, where the included contacts for source modeling were randomly selected and parametrically varied between 100%, 90%, 70%, and 50% of the remaining contacts. Ideally, the measurement at the left-out contact and the synthetic data should match each other. We used the percentage mean-squared-error as a metric to evaluate how much information was lost or retained in the source modeling.

Stability of the source modeling

The locations of electrode contacts were identified by the guidance of post-surgery MRI, where focal black spots were taken as the locations of electrode contacts because of the susceptibility effects. This procedure was recommended in a previous study (Stolk et al., 2018) and used to all patients in this study. Alternatively, electrode contacts were localized by the guidance of computer tomographic images after registered, with the help of the FSL (flirt function) package, and fused with the pre-surgery MRI. Two patients also followed this procedure to localize electrode contacts. We measured the average, standard deviation, minimal distance, and maximal distance between the discrepancy between two sets of electrode contact locations. Two different lead field matrices were calculated accordingly. We calculated the neural currents using these two lead field matrices and compared the differences in the estimated spatiotemporal dynamics of neural activity.

Results

Locations of electrode contacts

The locations of all electrode from all patients on a standard template (MNI 305) are shown in Figure 1 (B). Electrodes were distributed mostly around the temporal lobes and frontal lobes. Electrodes were implanted in both left and right hemispheres.

Estimated neural current distributions and dynamics

The estimated neural currents in response to the auditory stimuli in four representative patients are shown in Figure 2. Strong activity starting at around 120 ms was found at the left and right temporal lobes for representative patients with electrodes at the left and right temporal lobes, respectively. The spatial distribution and the waveform of the source estimates averaged across patients were shown in Figure 1 (C). The noisier response at the right hemisphere could be related to the SNR and sensitivity distributions (Figure 6) and the nature of the physiological response.

Figure 2.

Figure 2.

Spatial distributions of significant neural current estimates at about 120 ms after the sound onset in four representative patients with electrodes implanted in left (s027 and s033) and right (s031 and s041) hemispheres. These distributions at orthogonal anatomical slices (L: left hemisphere) and over an inflated brain model are shown at the left and right columns, respectively. The average and the standard deviation of the significance time course within the auditory cortex determined from all patients are shown at the right columns.

Figure 6.

Figure 6.

Distributions of the average SNR and sensitivity across patients with electrodes implanted in the left and right hemispheres. Colors code values sorted between the top 85% and 99% of the average.

High-frequency broadband gamma (HBBG) activity

We examined the spatial distribution of HBBG due to the auditory stimulus between 60 Hz and 140 Hz. Figure 3A shows spatial distributions of significantly increased and decreased HBBG in STG and IFG from all patients with electrodes implanted in the left hemisphere, respectively. These HBBG power changes were further validated from the electrode measurements of three patients, who had electrodes implanted in both left STG and IFG (Figure 3C and 3D). Similar patterns of significantly increased and decreased HBBG were observed by leaving either one of the three validation patients away from the group average analysis. The source modeling results matched the finding at the electrode around the left STG and IFG by showing significantly increased and decreased HBBG power, respectively. We did not observe other significant temporal subregional difference.

Figure 3.

Figure 3.

Spatial distributions of HBBG estimates between 60 Hz and 140 Hz in response to the auditory stimulus. (A) Significantly increased auditory HBBG activity were found in STG, whereas the HBBG in IFG was significantly decreased. (B) The recordings from three patients with electrodes implanted at STG and IFG were used to validate the source analysis result: The dark red circles show the locations of the electrode contacts closest to the STG and IFG locations of interest, the blue circles denote the rest of the electrode contacts. (C) The time-frequency representations (TFR) of the data from the electrode T, which is close to STG, show evidence of significantly increased HBBG activity at about 100 Hz between 100 ms and 400 ms after the stimulus onset. The data from the electrodes O and D, which is near IFG, show evidence of significant HBBG decreases, respectively. (D) Leave-one-out between-subject cross-validation analyses: The TFR results at 100 Hz from the electrodes T, D, and O were consistent with the source modeling of the estimated HBBG power at the group level. Notably, each of the group representations at the bottom panel include all patients except the one whose electrode data was utilized for the between-subject cross-validation.

Cross-validation

Distributed source modeling provides estimates of spatially distributed currents. As a model, the estimated neural current is different from the true neural current. Using leave-one-out validation, we quantified this discrepancy (Table 2). The average proportion of the explained variance dropped from 38% to 24% as fewer (from 100% to 50%) remaining electrode contacts were used for modeling the source. Depending on the number of electrode contacts used for modeling, the explained variance at an electrode contact ranged between 49% and 22%. No significant relationship between the number of electrode contacts and the proportion of the explained variance was found. This was presumably due to the fact that the number and location of electrodes for each patient were planned based on the clinical need rather than the auditory study.

Table 2.

Percentages of the variance explained by the source modeling in the cross-validation analysis.

Patient Percentage of remaining contacts (N-1) for source modeling Number of electrode contacts (N) Electrode at hemisphere
100% 90% 70% 50% left hemi. right hemi.
s026 38% 34% 23% 28% 69 +
s027 36% 32% 32% 17% 104 +
s031 22% 21% 18% 18% 95 +
s032 33% 31% 30% 26% 67 +
s033 44% 45% 34% 30% 76 +
s034 36% 33% 32% 27% 100 +
s036 49% 37% 37% 19% 59 +
s041 42% 34% 22% 19% 70 + +
max. 49% 45% 37% 33% 104
min. 22% 21% 18% 17% 59
average 38% 33% 29% 24% 80
standard deviation 8% 7% 6% 7% 17

Numbers for each patient and the average, maximum, minimum, and standard deviation across patients are reported. The presence and absence of the electrodes at hemispheres were denoted by “+” and “−” respectively.

Sensitivity

The spatial distributions of SNR and sensitivity across patients in the left and right hemispheres are shown in Figures 4 and 5, respectively. Color coded the brain locations with SNR or sensitivity between the top 85% and 99% of the values across the cortex. Note that only patients with electrodes implanted at one hemisphere were included in the plot of the same hemisphere. Approximate locations of electrode contacts to the cortex were indicated by green dots in the figure. Regions with high SNR and sensitivity were found in the vicinity of electrode contacts. Within an individual, the spatial distributions of SNR and sensitivity were very visually similar, suggesting that the estimated noise distributions were rather spatially homogeneous. The SNR and sensitivity in the thalamus and brain stem were comparable to those locations at the vicinity of electrode contact implantation: they were about the top 85% of the SNR and sensitivity. Figure 6 shows the spatial distributions of average SNR and sensitivity across patients with electrodes implanted in the left and right hemispheres in brain surfaces and volumes, respectively. Top 15% values were color-coded. High SNR and sensitivity were found around the anterior temporal lobe, insula, and frontal lobe, where electrodes were implanted based on the clinical need to ascertain epileptogenic zones. Both medial and lateral aspects of the cortex and deep brain areas, including part of the brain stem, had high SNR and sensitivity.

Figure 4.

Figure 4.

Distributions of the SNR and sensitivity for patients with electrode contacts in the left hemisphere. Colors code values sorted between the top 85% and 99% of each individual patient. Green dots denote the location of electrode contacts.

Figure 5.

Figure 5.

Distributions of the SNR and sensitivity for patients with electrode contacts in the right hemisphere. Colors code values sorted between the top 85% and 99% of each individual patient.

We quantitatively characterized how the SNR and sensitivity at a brain location varied with its distance to electrode contacts. Specifically, we considered two distance metrics, the minimum and the median of all distances between a brain location and all electrode contacts. The distributions of both distance metrics versus SNR and sensitivity for each patient and all patients in the logarithm scale were shown in Figures 7 and 8 respectively. These distributions were visually similar across patients.

Figure 7.

Figure 7.

Scatter plots between the brain-electrode distance and SNR and sensitivity in individual patients in the log-log scale. The distance measures include the median and the minimum distances between the estimated brain area and electrode contact locations. Regression lines between the minimum distance and the SNR or sensitivity are also shown.

Figure 8.

Figure 8.

Scatter plots between the brain-electrode distance and SNR and sensitivity across all patients in the log-log scale. The distance measures include the median and the minimum distance between the source-estimated brain area and electrode contact locations. Regression lines between the minimum distance and the SNR or sensitivity were shown.

In the logarithm scale, the distributions of SNR and sensitivity versus the minimum of the distance appeared to be better described by an inverse linear model than the distributions of SNR and sensitivity versus the median of the distance. The regression identified a significant inverse linear relationship between the 10-based logarithm of the SNR and the 10-based logarithm of the minimum distance with a slope of −3.6 and an intercept of −16.6 (p < 0.01). A significant inverse linear relationship between the 10-based logarithm of the sensitivity and the 10-based logarithm of the minimum distance was found with a slope of −3.7 and an intercept of −13.3 (p < 0.01). Both regression lines suggested that when the minimal distance became ten-fold larger (e.g., 1 mm to 10 mm), the SNR and sensitivity dropped to 0.25% and 0.20%, respectively.

The effect of the variability in electrode contact locations

The locations of electrode contacts informed by CT and post-surgery MRI on two representative patients are shown in Figure 9. While small, the discrepancy between the estimated locations of electrode contacts by CT and post-surgery MRI was still visually discernable. The average, standard deviation, maximal, and minimal distance between electrode contacts informed by CT and post-surgery MRI were and 1.39 mm ± 0.63 mm, 2.87 mm, and 0.24 mm for one patient and 2.61 ± 0.83 mm, 4.33 mm, and 0.92 mm for the other patient. The dSPMs estimated from two lead field matrices with electrode contact locations informed by CT or post-surgery MRI were shown in Figure 9. The spatial distributions and the waveform of the significance of the neural currents were similar. Quantitatively, the correlation coefficients of the spatiotemporal dynamics between two lead field matrices were both 0.97 in two patients. The ratios of the power of the dSPM difference between two lead field matrices and the average power of the dSPM between two lead field matrices were 3.34% and 4.04% for patient s026 and s041, respectively.

Figure 9.

Figure 9.

Source modeling based on the electrode contacts suggested by the post-surgery MRI and CT. Locations of the electrode contacts suggested by the post-surgery MRI and CT (top panel), the estimated neural current distributions using the electrode contact locations informed by CT (the second row from the top) and post-surgery MRI (the third row from the top), and the time courses of statistical significance in the auditory cortex from two representative patients.

Discussion

Here, we describe a novel procedure to estimate a neural current distribution based on the discrete sampling of sEEG data with realistic anatomical information from MRI. In our empirical data with auditory stimulation, the estimated sources of activations were localized in the vicinity of auditory cortices of the superior temporal plane (Figure 2). Notably, as we hypothesized, the source localization results were anatomically highly consistent across participants (Figure 1), even though the locations of electrode contacts were highly variable across individuals. These results may be related to the fact that electrodes were mostly implanted in the temporal lobe and had consequently a higher SNR, and the presented auditory stimuli likely induced strong neural activity in the temporal lobe. Further, our source estimation conducted in the frequency domain revealed significantly increased 60–140 Hz HBBG in STG, and HBBG decreases in IFG, consistent with the analyses of the directly recorded sEEG signal (Figure 3). While this analysis included only three patients because of the limitation of current cohort, similar results were obtained by leaving one patient out in the HBBG analysis supported the reproducibility of individual’s HBBG. These results suggest that distributed source modeling of sEEG data offers a powerful way to conduct anatomically normalized human neurophysiological research at the group level, and thus opens entirely new possibilities for basic and clinical neuroscience research with sEEG recordings.

Sensitivity and SNR

In this study, we systematically examined the sensitivity and SNR distributions of the estimated neural current accounting for the recorded sEEG data. The results show that the sensitivity and the SNR of the sEEG recording depend strongly on the distance between the estimated area vs. electrode contact location (Figures 4, 5, and 6). When we considered individual electrode locations, the sensitivity and SNR can become tens or hundreds of times smaller if the current source locations in the model is as little as one millimeter away from the nearest electrode contact (Figures 7 and 8). The sharp drop of SNR and sensitivity for a moderate increase in the minimal distance, together with the cross-validation analysis (Table 2), suggested that precise electrode implantation is important to record the desired neural activity at the target brain locations. However, as the neural currents were estimated from an ensemble of sEEG electrodes, the dependency of the sensitivity and SNR on the distances between the brain region of interest and all electrode contacts was more complicated: The sensitivity and SNR can be comparable when the median distance from a brain location to all electrode contacts differed by a few centimeters. Therefore, combining data from multiple sEEG electrode contacts greatly improves the sensitivity and SNR. Note that we did not take a square root in the sensitivity calculation. The relationship between sensitivity and distance was characterized in a log-log scale. Thus, the relationship would naturally change if a square root is taken on the sensitivity.

Inclusion of deep brain source locations

Facilitated by the computational anatomy, we were able to examine the sensitivity and SNR distribution at regions with automatically segmented anatomical labels. We were particularly interested in the deep brain areas, where non-invasive MEG and EEG measurements have a very limited sensitivity (Baillet et al., 2001). Consistent with the fact that sEEG electrode contacts are in the proximity of deep brain areas, we found that the sensitivity and the SNR in, for example, the thalamus and brain stem were comparable to those of several cortical locations (Figure 5). This result supports the feasibility of using distributed source modeling of sEEG data to examine the interactions between cortical and subcortical areas.

We found significant neural currents in deep brain areas. However, we were not able to pinpoint the locations toward the medial geniculate body or inferior colliculus, part of the known sub-cortical areas involved in the auditory processing pathway. To better identify neural currents at these potential regions, we may thus need to limit the source space to the candidate locations as a prior constraint. This solution would, however, come with the price of neglecting neural currents from locations outside the modeled regions.

Cross-validation

We cross-validated the accuracy of the source modeling of sEEG data using the leave-one-out approach. Note that this cross-validation is different from the “goodness-of-fit” in MEG/EEG analyses. In our cross-validation, the data used to estimate the source distribution and the data used for prediction were exclusive sets. On the contrary, the “goodness-of-fit” in MEG/EEG analyses was derived from the same set of measurement for both estimating the source distribution and predicting the measurement based on the estimated sources. Our cross-validation suggested that about 30–50% of the variance can be explained by the proposed source modeling (Table 2). In other words, despite the limiting effects of the sharp drop-off of the sensitivity of sEEG at locations away from the recording sites (Figures 6 and 7), the source modeling still explained a significant portion of the variance. This is probably because of the elicited neural activity is spatially distributed and the model favors a spatially extended source distribution to explain the measurements. In such a case, the L-2 norm-based distributed source modeling can reasonably describe the distribution of the neural activity at areas away from the implanted electrodes.

Potential factors related to the cross-validation performance reported here include the choice of the experimental paradigm, the forward model, and the source model. Here we used the neural responses to rather simple auditory stimuli (white noise bursts) with a priori well-known foci of response activity as the means to validate the predicted sEEG measurements. Such empirical validation is closely related to how much neural activity was actually elicited by the auditory stimuli. If the elicited neural activity is focal, it is difficult to estimate such an activity from measurements at other contact locations with minimal responses. Accordingly, if the elicited neural activity is spatially diffuse, the estimated the neural activity could have better matched the measurement at the left-out contacts. This potential confound should be considered in the interpretation of our results.

The forward model used in this study can mitigate the challenge of calculating the electric potential within the neural current volume (Gramfort et al., 2010; Kybic et al., 2005). More complicated forward models, such as the one using the Finite Element Model (Wolters et al., 2006), or simpler models, such as the one assuming a simple spherical geometry and homogeneous conductivity (Yvert et al., 2005), could provide a potential alternative for our choice for the trade-off between accuracy and computational complexity. Additional benefits in the forward calculations could be achieved by using recently introduced boundary element fast multipole methods, which simulate anatomically realistic head models with unprecedented numerical accuracy and speed (Makarov et al., 2020). As for the source model, we used the MNE for its computational efficiency. Other choices, such as the one preferring focal neural current estimate by imposing a constraint to minimize its L-1 norm, such as the minimum-current estimate (Uutela et al., 1999), may be further investigated in the future. Good performance in the cross-validation analysis may only appear in experiments where spatially extensive neural currents are present. For experiments with a focal neural current distribution, such as that in the early response of sensory processing in normal subjects and inter-ictal discharges in epilepsy patients, the performance of cross-validation may be low, because estimating neural currents from contacts other than the one close to the focal neural current can be difficult. Yet again, in such cases, very strong a priori hypotheses of the probable source location are available, in contrast to the more complex cognitive processes.

Registration

Previous studies using the combination of CT and MRI suggested that the accuracy of identifying the locations of electrode contacts was in the range of about 1 mm (Blenkmann et al., 2017). In our study, we used the MRI before and after electrode implantation to identify the locations of sEEG electrodes. Specifically, focal dark spots in the post-surgery MRI were taken as the sites of electrode contacts. However, the distortion in the post-surgery MRI due to the susceptibility and the spatial resolution of MRI can confound the accuracy of the electrode contract localization. Using only MRI to inform the electrode contact location had the benefit of reducing the exposure to ionizing radiation in a CT scan. Without a gold standard, it is difficult to judge whether the electrode registration is more accurate with either MRI or CT. Both MRI and CT have distinct challenges in localizing electrode contacts: CT needs to be registered to MRI, and a smooth skull has limited features to warrant accurate registration between CT and MRI. The skull of MRI is an essential part may be difficult to be described accurately because of the concerns on MRI spatial resolution (about 1 mm) and distortion due to systematic (such as the nonlinearity property in MRI gradient coils (O’Donnell and Edelstein, 1985)) and physiological (such as the susceptibility discontinuity between the brain, cerebrospinal fluid, skull, and scalp interfaces) reasons (van der Kouwe et al., 2008).

Source estimates of high-frequency broadband gamma activity

Our results suggest that distributed source estimation could also be utilized for analyses of HBBG activity. Evidence for significantly increased HBBG to sound stimuli was found in the vicinity of auditory cortices. Interestingly, we found evidence of decreased HBBG in IFG and nearby areas right after the onset of the auditory stimulus, an effect that could reflect suppression of involuntary attention networks due to the repetitive nature of the non-target auditory stimulus (for reviews, see Jääskeläinen et al., 2011; Jääskeläinen et al., 2007). The most important result of the present analysis, however, was the considerable consistency of the source estimates of HBBG and the electrode data obtained from contacts in the vicinity of STG and IFG. These novel results suggest that distributed source modeling analyses is a way to conduct anatomically-normalized group analyses of this highly essential neural activity, which is believed to constitute a direct correlate of local firing activity in the human brain (Manning et al., 2009; Miller, 2010; Ray and Maunsell, 2011).

Sample size

In this study, we analyzed data from eight epilepsy patients who volunteered for our study during their medically implicated intracranial monitoring. Albeit smaller than a typical non-invasive study, where basically an unlimited pool of potential subjects is available, our sample size is either larger or compatible with those in previous comparable sEEG studies: (n = 1, (Caune et al., 2014); n = 3, (Yvert et al., 2005); n = 9, (Zheng et al., 2017); and n = 1 (Cam et al., 2017)).

Future studies

There are a few issues worth studying further. For example, it is not known how the regularization parameter modulates the current source estimate. The regularization parameter is crucial in deriving a stable solution because of the ill-posed nature of the lead fields in extracranial MEG/EEG measurements. However, in sEEG, the lead fields can vary significantly across patients due to different electrode implantation scheme. Further, the conditioning number of the lead field matrix in sEEG can be less ill-posed. Thus, how to optimize the regularization parameter is still an open question. In this study, we used the strategy in our previous MEG study to determine the regularization parameter. Because the optimal regularization parameter has not been systematically studied in the context of SEEG source modeling, we can only resort to our experience of MEG/EEG source modeling, which was the framework we extended to the present study, for a strategy to determine the regularization parameter. Possible additional methods for estimating the regularization parameter, in future studies, include the L-curve (Hansen, 1998) and Generalized Cross-Validation (Golub et al., 1977). Second, we derived the group inference by averaging neural current estimates across patients. Given quantitative estimates of sensitivity and SNR, it might be reasonable to weight the neural current estimates by sensitivity or SNR. However, without a gold standard, it is still difficult to justify whether such SNR or sensitivity weighted group average is a better choice.

Conclusions

While sEEG provides unsurpassed spatiotemporal accuracy, the interpretation of results has been complicated because the loci of electrode implantations differ greatly across individual patients. Here, we describe a distributed, anatomically realistic sEEG source-modeling approach with which it becomes possible to estimate both iERP and HBBG responses in any given cortical or subcortical location at group level. Distributed sEEG source modeling of iERP and HBBG responses provides a new powerful neuroimaging tool that opens up a wealth of possibilities for both basic and clinical neuroscience research.

Acknowledgments

This study was supported by Natural Sciences and Engineering Research Council of Canada (RGPIN-2020-05927), Ministry of Science and Technology, Taiwan (103-2628-B-002-002-MY3, 105-2221-E-002-104), National Health Research Institutes (NHRI-EX108-10727EI), the Academy of Finland (project numbers 138145 and 276643 to IPJ and 298131 to FHL), aivoAALTO project funding of the Aalto University, National Institute on Deafness and other Communication Disorders (R01DC016765 supported JA, FHL, WJK; R01DC017991 supported JA, IPJ; R01DC016915 supported JA) and Russian Federation Government grant ag. 075-15-2019-1930 to I.P.J.

Footnotes

Competing interests

The authors declare no competing interests.

All data used in this study are available via a request to the corresponding author after signing the data sharing agreement approved by Sunnybrook Research Institute. Codes used for this study are open to access at https://github.com/fahsuanlin/fhlin_toolbox/wiki.

References

  1. Alhilani M, Tamilia E, Ricci L, Ricci L, Grant PE, Madsen JR, Pearl PL, Papadelis C, 2020. Ictal and interictal source imaging on intracranial EEG predicts epilepsy surgery outcome in children with focal cortical dysplasia. Clin Neurophysiol 131, 734–743. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Baillet S, Mosher JC, Leahy RM, 2001. Electromagnetic brain mapping. IEEE Signal Processing Magazine 18, 14–30. [Google Scholar]
  3. Bartolomei F, Lagarde S, Wendling F, McGonigal A, Jirsa V, Guye M, Benar C, 2017. Defining epileptogenic networks: Contribution of SEEG and signal analysis. Epilepsia 58, 1131–1147. [DOI] [PubMed] [Google Scholar]
  4. Blenkmann AO, Phillips HN, Princich JP, Rowe JB, Bekinschtein TA, Muravchik CH, Kochen S, 2017. iElectrodes: A Comprehensive Open-Source Toolbox for Depth and Subdural Grid Electrode Localization. Front Neuroinform 11, 14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Buzsaki G, Anastassiou CA, Koch C, 2012. The origin of extracellular fields and currents--EEG, ECoG, LFP and spikes. Nat Rev Neurosci 13, 407–420. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Cam SL, Ranta R, Caune V, Korats G, Koessler L, Maillard L, Louis-Dorr V, 2017. SEEG dipole source localization based on an empirical Bayesian approach taking into account forward model uncertainties. Neuroimage 153, 1–15. [DOI] [PubMed] [Google Scholar]
  7. Cardinale F, Cossu M, Castana L, Casaceli G, Schiariti MP, Miserocchi A, Fuschillo D, Moscato A, Caborni C, Arnulfo G, Lo Russo G, 2013. Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 72, 353–366; discussion 366. [DOI] [PubMed] [Google Scholar]
  8. Caune V, Le Cam S, Ranta R, Maillard L, Louis-Dorr V, 2013. Dipolar source localization from intracerebral SEEG recordings. Conf Proc IEEE Eng Med Biol Soc 2013, 41–44. [DOI] [PubMed] [Google Scholar]
  9. Caune V, Ranta R, Le Cam S, Hofmanis J, Maillard L, Koessler L, Louis-Dorr V, 2014. Evaluating dipolar source localization feasibility from intracerebral SEEG recordings. Neuroimage 98, 118–133. [DOI] [PubMed] [Google Scholar]
  10. Cervenka MC, Nagle S, Boatman-Reich D, 2011. Cortical high-gamma responses in auditory processing. Am J Audiol 20, 171–180. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Dale AM, Liu AK, Fischl BR, Buckner RL, Belliveau JW, Lewine JD, Halgren E, 2000. Dynamic statistical parametric mapping: combining fMRI and MEG for high-resolution imaging of cortical activity. Neuron 26, 55–67. [DOI] [PubMed] [Google Scholar]
  12. De Momi E, Caborni C, Cardinale F, Castana L, Casaceli G, Cossu M, Antiga L, Ferrigno G, 2013. Automatic trajectory planner for StereoElectroEncephaloGraphy procedures: a retrospective study. IEEE Trans Biomed Eng 60, 986–993. [DOI] [PubMed] [Google Scholar]
  13. Fischl B, Salat DH, Busa E, Albert M, Dieterich M, Haselgrove C, van der Kouwe A, Killiany R, Kennedy D, Klaveness S, Montillo A, Makris N, Rosen B, Dale AM, 2002. Whole brain segmentation: automated labeling of neuroanatomical structures in the human brain. Neuron 33, 341–355. [DOI] [PubMed] [Google Scholar]
  14. Fischl B, Sereno MI, Tootell RB, Dale AM, 1999. High-resolution intersubject averaging and a coordinate system for the cortical surface. Hum Brain Mapp 8, 272–284. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Goldenholz DM, Ahlfors SP, Hamalainen MS, Sharon D, Ishitobi M, Vaina LM, Stufflebeam SM, 2009. Mapping the signal-to-noise-ratios of cortical sources in magnetoencephalography and electroencephalography. Hum Brain Mapp 30, 1077–1086. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Golub GH, Heath M, Grace W, 1977. Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter. Technometrics 21, 215–223. [Google Scholar]
  17. Gonzalez-Martinez J, Mullin J, Vadera S, Bulacio J, Hughes G, Jones S, Enatsu R, Najm I, 2014. Stereotactic placement of depth electrodes in medically intractable epilepsy. J Neurosurg 120, 639–644. [DOI] [PubMed] [Google Scholar]
  18. Gramfort A, Papadopoulo T, Olivi E, Clerc M, 2010. OpenMEEG: opensource software for quasistatic bioelectromagnetics. Biomed Eng Online 9, 45. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Hamalainen MS, Ilmoniemi RJ, 1994. Interpreting magnetic fields of the brain: minimum norm estimates. Med Biol Eng Comput 32, 35–42. [DOI] [PubMed] [Google Scholar]
  20. Hämäläinen MS, Ilmoniemi RJ, 1984. Interpreting magnetic fields of the brain: minimum norm estimates. Helsinki University of Technology, Espoo: TKK-F-A559. [DOI] [PubMed] [Google Scholar]
  21. Hansen PC, 1998. Rank-deficient and discrete ill-posed problems : numerical aspects of linear inversion. SIAM, Philadelphia, Pa. [Google Scholar]
  22. Hosseini SAH, Sohrabpour A, He B, 2018. Electromagnetic source imaging using simultaneous scalp EEG and intracranial EEG: An emerging tool for interacting with pathological brain networks. Clin Neurophysiol 129, 168–187. [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Iivanainen J, Zetter R, Parkkonen L, 2020. Potential of on-scalp MEG: Robust detection of human visual gamma-band responses. Hum Brain Mapp 41, 150–161. [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Jääskeläinen IP, Ahveninen J, Andermann ML, Belliveau JW, Raij T, Sams M, 2011. Short-term plasticity as a neural mechanism supporting memory and attentional functions. Brain Res 1422, 66–81. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Jääskeläinen IP, Ahveninen J, Belliveau JW, Raij T, Sams M, 2007. Short-term plasticity in auditory cognition. Trends Neurosci 30, 653–661. [DOI] [PubMed] [Google Scholar]
  26. Jonas J, Frismand S, Vignal JP, Colnat-Coulbois S, Koessler L, Vespignani H, Rossion B, Maillard L, 2014. Right hemispheric dominance of visual phenomena evoked by intracerebral stimulation of the human visual cortex. Hum Brain Mapp 35, 3360–3371. [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Jonas J, Jacques C, Liu-Shuang J, Brissart H, Colnat-Coulbois S, Maillard L, Rossion B, 2016. A face-selective ventral occipito-temporal map of the human brain with intracerebral potentials. Proc Natl Acad Sci U S A 113, E4088–4097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Koessler L, Cecchin T, Colnat-Coulbois S, Vignal JP, Jonas J, Vespignani H, Ramantani G, Maillard LG, 2015. Catching the invisible: mesial temporal source contribution to simultaneous EEG and SEEG recordings. Brain Topogr 28, 5–20. [DOI] [PubMed] [Google Scholar]
  29. Kybic J, Clerc M, Abboud T, Faugeras O, Keriven R, Papadopoulo T, 2005. A common formalism for the integral formulations of the forward EEG problem. IEEE Trans Med Imaging 24, 12–28. [DOI] [PubMed] [Google Scholar]
  30. Lin FH, Belliveau JW, Dale AM, Hämäläinen MS, 2006. Distributed current estimates using cortical orientation constraints. Hum Brain Mapp 27, 1–13. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Makarov S, Hamalainen M, Okada Y, Noetscher GM, Ahveninen J, Nummenmaa A, 2020. Boundary Element Fast Multipole Method for Enhanced Modeling of Neurophysiological Recordings. IEEE Transactions on Biomedical Engineering, 1–1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Manning JR, Jacobs J, Fried I, Kahana MJ, 2009. Broadband shifts in local field potential power spectra are correlated with single-neuron spiking in humans. J Neurosci 29, 13613–13620. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Miller KJ, 2010. Broadband spectral change: evidence for a macroscale correlate of population firing rate? J Neurosci 30, 6477–6479. [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Mittal S, Barkmeier D, Hua J, Pai DS, Fuerst D, Basha M, Loeb JA, Shah AK, 2016. Intracranial EEG analysis in tumor-related epilepsy: Evidence of distant epileptic abnormalities. Clin Neurophysiol 127, 238–244. [DOI] [PubMed] [Google Scholar]
  35. Narizzano M, Arnulfo G, Ricci S, Toselli B, Tisdall M, Canessa A, Fato MM, Cardinale F, 2017. SEEG assistant: a 3DSlicer extension to support epilepsy surgery. BMC Bioinformatics 18, 124. [DOI] [PMC free article] [PubMed] [Google Scholar]
  36. O’Donnell M, Edelstein WA, 1985. NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. Med Phys 12, 20–26. [DOI] [PubMed] [Google Scholar]
  37. Parvizi J, Kastner S, 2018. Promises and limitations of human intracranial electroencephalography. Nat Neurosci 21, 474–483. [DOI] [PMC free article] [PubMed] [Google Scholar]
  38. Pascarella A, Todaro C, Clerc M, Serre T, Piana M, 2016. Source modeling of ElectroCorticoGraphy (ECoG) data: Stability analysis and spatial filtering. J Neurosci Methods 263, 134–144. [DOI] [PubMed] [Google Scholar]
  39. Piai V, Anderson KL, Lin JJ, Dewar C, Parvizi J, Dronkers NF, Knight RT, 2016. Direct brain recordings reveal hippocampal rhythm underpinnings of language processing. Proc Natl Acad Sci U S A 113, 11366–11371. [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Pistohl T, Schulze-Bonhage A, Aertsen A, Mehring C, Ball T, 2012. Decoding natural grasp types from human ECoG. Neuroimage 59, 248–260. [DOI] [PubMed] [Google Scholar]
  41. Ramantani G, Cosandier-Rimele D, Schulze-Bonhage A, Maillard L, Zentner J, Dumpelmann M, 2013. Source reconstruction based on subdural EEG recordings adds to the presurgical evaluation in refractory frontal lobe epilepsy. Clin Neurophysiol 124, 481–491. [DOI] [PubMed] [Google Scholar]
  42. Ray S, Maunsell JH, 2011. Different origins of gamma rhythm and high-gamma activity in macaque visual cortex. PLoS Biol 9, e1000610. [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Rikir E, Koessler L, Gavaret M, Bartolomei F, Colnat-Coulbois S, Vignal JP, Vespignani H, Ramantani G, Maillard LG, 2014. Electrical source imaging in cortical malformation-related epilepsy: a prospective EEG-SEEG concordance study. Epilepsia 55, 918–932. [DOI] [PubMed] [Google Scholar]
  44. Serletis D, Bulacio J, Bingaman W, Najm I, Gonzalez-Martinez J, 2014. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. J Neurosurg 121, 1239–1246. [DOI] [PubMed] [Google Scholar]
  45. Stolk A, Griffin S, van der Meij R, Dewar C, Saez I, Lin JJ, Piantoni G, Schoffelen JM, Knight RT, Oostenveld R, 2018. Integrated analysis of anatomical and electrophysiological human intracranial data. Nat Protoc 13, 1699–1723. [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Tang C, Hamilton LS, Chang EF, 2017. Intonational speech prosody encoding in the human auditory cortex. Science 357, 797–801. [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Uutela K, Hamalainen M, Somersalo E, 1999. Visualization of magnetoencephalographic data using minimum current estimates. Neuroimage 10, 173–180. [DOI] [PubMed] [Google Scholar]
  48. van der Kouwe AJW, Benner T, Salat DH, Fischl B, 2008. Brain morphometry with multiecho MPRAGE. Neuroimage 40, 559–569. [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Wang Q, Valdes-Hernandez PA, Paz-Linares D, Bosch-Bayard J, Oosugi N, Komatsu M, Fujii N, Valdes-Sosa PA, 2019. EECoG-Comp: An Open Source Platform for Concurrent EEG/ECoG Comparisons-Applications to Connectivity Studies. Brain Topogr 32, 550–568. [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Wolters CH, Anwander A, Tricoche X, Weinstein D, Koch MA, MacLeod RS, 2006. Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: a simulation and visualization study using high-resolution finite element modeling. Neuroimage 30, 813–826. [DOI] [PubMed] [Google Scholar]
  51. Yvert B, Fischer C, Bertrand O, Pernier J, 2005. Localization of human supratemporal auditory areas from intracerebral auditory evoked potentials using distributed source models. Neuroimage 28, 140–153. [DOI] [PubMed] [Google Scholar]
  52. Zhang H, Watrous AJ, Patel A, Jacobs J, 2018. Theta and Alpha Oscillations Are Traveling Waves in the Human Neocortex. Neuron 98, 1269–1281 e1264. [DOI] [PMC free article] [PubMed] [Google Scholar]
  53. Zheng J, Anderson KL, Leal SL, Shestyuk A, Gulsen G, Mnatsakanyan L, Vadera S, Hsu FP, Yassa MA, Knight RT, Lin JJ, 2017. Amygdala-hippocampal dynamics during salient information processing. Nat Commun 8, 14413. [DOI] [PMC free article] [PubMed] [Google Scholar]

RESOURCES