Skip to main content
Data in Brief logoLink to Data in Brief
. 2021 Mar 23;36:106989. doi: 10.1016/j.dib.2021.106989

A dataset of visible – Short wave InfraRed reflectance spectra collected on pre-cooked pasta products

Giuseppe Bonifazi a,b,, Riccardo Gasbarrone a, Giuseppe Capobianco a, Silvia Serranti a,b
PMCID: PMC8050707  PMID: 33889694

Abstract

Reflectance Visible (Vis) and Short Wave Infrared (SWIR) spectra of pre-cooked pasta products were collected in a non-invasive way by using an ASD FieldSpec® 4 Standard–Res portable spectrophotoradiometer (350–2500 nm). Vis-SWIR data were collected on 6 samples of Pennette 72 and 6 samples of Mezze Penne with different salting levels with the aid of a contact probe in two different physical conditions: i) frozen and ii) thawed. Fifty Vis-SWIR spectra were collected per measurement time from each sample resulting in 1200 raw spectra.

The dataset presented in this descriptor can be used to explore the possibilities to develop automated methods to perform pre-cooked pasta analysis. Vis-SWIR data have potential reuse for follow-up studies finalized to develop pre-cooked pasta quality control applications by using similar devices or to test the ability of different chemometric algorithms.

Keywords: Reflectance spectroscopy dataset, Near infrared spectroscopy, Pasta products, Cold chain maintenance evaluation

Specifications Table

Subject Spectroscopy.
Specific subject area Biophotonics; food quality control applications.
Type of data Table (.mat and .csv files).
How data were acquired Portable Visible (Vis) and Short Wave InfraRed /SWIR) spectroscopy.
ASD FieldSpec® 4 Standard–Res field portable spectroradiometer in reflectance mode in the wavelength range of 350–2500 nm with a spectral resolution of 3 nm at 700 nm and 10 nm at 1400/2100 nm, resulting in 2151 variables/measurement.
Data format Raw data, analysed data.
Parameters for data collection A Spectralon (reflectance >99%) standard material was used for calibrating the instrument, followed by dark current. Calibration was performed for each cycle of sample acquisition. The analyzed samples consist of two types of pre-cooked pasta, with different degrees of salting - Pennette72 and Mezze Penne - in two physical conditions: frozen (just taken out from the dry ice icebox) and thawed (after about two hours left to rest at a temperature of 26 °C).
Description of data collection Reflectance spectra were acquired with a portable spectroradiometer aided by a contact probe from pre-cooked pasta samples in different physical conditions (being frozen/being thawed). Fifty spectra acquisitions were performed, for each pre-cooked pasta sample, using a portable spectrophotoradiometer, after a specific calibration procedure. The collected data can be imported into MATLAB environment to perform the analysis.
Data source location Institution: Raw Materials Laboratory, Sapienza University of Rome.
City/Town/Region: Latina (LT), Lazio.
Country: Italy.
Data accessibility The datasets described in this paper are hosted in a public repository.
Repository name: Bonifazi, Giuseppe; Gasbarrone, Riccardo; Capobianco, Giuseppe; Serranti, Silvia (2021), “A dataset of Visible – Short Wave InfraRed reflectance spectra collected on pre-cooked pasta products”, Mendeley Data, V2, doi: 10.17632/yhyzmp8rtb.2
Direct URL to data: http://dx.doi.org/10.17632/yhyzmp8rtb.2

Value of the Data

  • The dataset can be used as a reference set of spectral signatures of pre-cooked pasta, and for the development of automated methods of pasta-based products' physical condition evaluation.

  • Researchers working with visible and near infrared spectroscopy, especially the reflectance spectroscopy equipment used in combination with food control and pre-cooked pasta products quality inspection will benefit from these data, on a case–by–case basis, and depending on the personal investigation.

Data can be re-used: i) to set up multivariate classification models for discriminating pasta-based products according to their physical condition and ii) to perform multivariate regression for predicting the dry weight content of pre-cooked pasta.

1. Data Description

In recent times, more and more companies working in the pasta sector are starting to use methods based on Near InfraRed (NIR) spectroscopy, combined with chemometrics, allowing quick investigations in order to perform simultaneous determinations of different parameters [1], [2], [3].

Visible and NIR spectroscopy techniques are actually utilized to perform both qualitative and quantitative analysis in different fields: i.e. in primary/secondary raw materials sector [4], [5], in cultural heritage [6], [7], in the agricultural and food industry [8], [9], [10], [11], [12], [13], in the pharmaceutical and chemical industry [14], [15], in clinical application [16], [17], [18] and more generally in analytical science [19] to perform systematic environmental remote and proximal sensing. In this data descriptor, reflectance Visible (Vis) and Short Wave Infrared (SWIR) spectra of pre-cooked pasta products are reported.

Reflectance Vis- SWIR spectra of pre-cooked pasta product were acquired by an ASD FieldSpec® 4 Standard–Res field-portable spectrophotoradiometer (350–2500 nm). Vis-SWIR data were collected on 6 samples of Pennette 72 and 6 samples of Mezze Penne with different salting levels, by the aid of a contact probe, in two different physical conditions: i) frozen and ii) thawed.

The data records presented in this work are reported in a public repository (i.e. Mendeley Data) and consist of a MATLAB (MathWorks Inc., Natick, MA, USA) “.mat” file. More in detail, the “Pasta_dataset.mat” is a MATLAB data file containing a DataSet Object (DSO), the “Precooked_pasta” including the reflectance spectra collected for each sample. In the Row Labels section are reported 5 class sets:

  • i)

    Sample_ID: identification labels of each block of 50 measurements;

  • ii)

    Dry_weight_content_%: labels of the dry weight content measured on pasta product samples (42.8%, 46.7% and 47.5%);

  • iii)

    Pasta_type_&_phy_con: labels of the pasta product type referring to the physical condition (“Mezze Penne (frozen)”, “Pennette 72 (frozen)”, “Mezze Penne (thawed)” and “Pennette 72 (thawed)”);

  • iv)

    Phy_con: labels of the pasta products physical condition (“Frozen pasta” and “Thawed pasta”);

  • v)

    Pasta_type: labels of the pasta product type (“Pennette 72″ and “Mezze Penne”).

Reflectance spectra according to each class set are reported in Fig. 1. The “Precooked_pasta” DSO size (Number of spectra = 1200) is sufficient to build and validate multivariate models. Data ara also provided in .csv format (“Precooked_pasta.csv”). The instrument was calibrated before each set of acquisitions (i.e. after each block of 50 measurements), in order to ensure the repeatability of the acquired data.

Fig. 1.

Fig 1

Fig 1

Fig 1

Raw reflectance spectra (a) and spectra averaged according to the following class sets: dry weight content (b), pasta product type referring to the physical condition (c), pasta products physical condition (d), and pasta product type (e).

The averaged spectra of the pasta products characterized by different salting levels mainly differ in the visible region as can be seen in spectra plots (Fig. 1b and e). While the averaged spectra of the frozen and thawed samples mainly differ in intensities around most of the entire investigated spectral range (Fig. 1c and d). More in detail, “Frozen pasta” spectra show higher reflectance values than “Thawed pasta” in the spectral ranges: 350–1450 nm, 1600–1850 nm, and 2100–2400 nm. Furthermore, the averaged spectra of the frozen pasta products show more pronounced absorbances around 1450–1550 nm and 1900–2100 nm.

The strategy adopted to perform measurements is summarized in Fig. 2. Reflectance spectral data were collected by a portable spectrophotoradiometer, after a specific calibration procedure. Reflectance spectra were then pre-processed to eliminate the “gaps” located between the various acquisition domains of the three detectors of the ASD spectrophotoradiometer. All the gathered information can be imported into MATLAB environment to perform the analysis.

Fig. 2.

Fig 2

Schematic drawing of the adopted data handling procedure.

2. Experimental Design, Materials and Methods

Samples. The pasta samples analyzed in this study were provided by a company Gelit SpA, located in Cisterna di Latina (Lazio, Italy). The analyzed samples consist of two types of pre-cooked pasta products, with two different degrees of salting: 6 samples of Pennette72 and 6 samples of Mezze Penne. Approximately 200 g of each sample was placed in different plastic plates. Reflectance spectra were then collected in two stages: frozen (just taken out from the dry ice icebox) and thawed (after about two hours left to rest at a temperature of 26 °C).

Portable spectroradiometer system and spectra acquisition. Vis – SWIR (Visible – Short Wave InfraRed) A portable ASD FieldSpec® 4 Standard–Res spectrophotoradiometer was utilized to collect reflectance spectra.

The spectroradiometer, working in the 350 and 2500 nm wavelength range, is characterized by three detectors characterized by different spectral resolutions: 3 nm at 700 nm and 10 nm at 1400/2100 nm [20]. The instrument, controlled by a portable PC, is constituted by a detectors case and a fiber optics cable connected to a contact probe to perform reflectance measurements.

The spectrophotoradiometer has 3 different holographic diffraction gratings, each one coupled with a detector. In the detector case, order separation filters cover each detector for suppressing second and higher-order light.

Spectra are collected in 3 different wavelength ranges: 350–1000 nm, 1001–1800 nm, and 1801–2500 nm. Detection in the different wavelength ranges is carried out utilizing a 512 silicon array, a first Graded Index InGaAs photodiode (two stages TE cooled), and a second Graded Index InGaAs photodiode (two stages TE cooled) detectors, respectively. The energizing system, embedded in the contact probe, consists of a halogen bulb light source (color temperature equal to 2901 ± 10% °K). The length of the probe, including the grip, is about 25 cm. Inside the probe, the light source is placed at 12° from the normal axis to the contact probe spot plane (light source angle). The fiber optic head is placed at 35° from the normal axis to the contact probe spot plane (measurement angle). The spot size of the contact probe is 10 mm. The native software RS3 of the ASD instrument was used for data acquisition [20].

Instrument calibration procedure and spectral data handling. ASD FieldSpec® 4 Standard–Res spectroradiometer calibration was carried out utilizing a standardized white Spectralon® ceramic material from LabSphere, Inc. to set up the “white reference” (Wi). “Dark reference” (Di), was computed utilizing the dark current calibration file. After this calibration stage, the spectrum is acquired (R0i) and then reflectance (Ri) is computed by the ratio (R0iDi)/(WiDi).

The RS3 software (ASD Inc.) was utilized to perform the whole calibration and the spectra acquisition. Collection procedures are reported in “.asd” data files. Instrument “.asd” data files were stacked into an ASCII text file with the aid of ViewSpec Pro (Ver. 6.2.0.) software (ASD Inc.). The “fieldspec_import.m”, available at GitHub [21], was utilized to import the obtained ASCII text file into MATLAB® (MATLAB R2016b; Ver. 9.1.0.). Data were stored into a DSO and classes were set by using PLS_toolbox (ver. 8.2.1) by Eigenvector Research Inc.

Spectra acquisition. For each sample, 50 reflectance spectra were acquired by an ASD FieldSpec 4® Standard – Res spectrophotoradiometer equipped with a contact probe, in two different times: on frozen and thawed samples (for a total of 600 spectra for frozen samples and 600 spectra for thawed samples). Data acquisition was carried out using the ASD RS3™ software. The computed grand averages for all subjects of the raw mean spectra are shown in Fig. 1.

Spectra pre-processing. Spectra have been preprocessed in order to reduce noise, minimizing, at the same time, degradation of the essential information. The pre-processing algorithm applied to the spectral data was the so-called Splice Correction (SC) [22]. It was applied to eliminate the “gaps” located between the various acquisition domains of the three detectors of the ASD spectrometer. To make the user free to choose any preferred preprocessing method, the Vis–SWIR spectra included in the present dataset are only preprocessed with SC.

CRediT Author Statement

Giuseppe Bonifazi: Conceptualization, Methodology, Validation, Resources, Writing - Review & Editing, Visualization, Supervision; Riccardo Gasbarrone: Conceptualization, Methodology, Software, Validation, Formal analysis, Investigation, Data Curation, Writing - Original Draft, Writing - Review & Editing, Visualization; Giuseppe Capobianco: Conceptualization, Validation, Writing - Original Draft, Writing - Review & Editing; Silvia Serranti: Conceptualization, Methodology, Validation, Resources, Writing - Review & Editing, Visualization, Supervision.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships which have, or could be perceived to have, influenced the work reported in this article.

Acknowledgments

The authors wish to thank the company Gelit SpA (Latina, Italy) to have provided the samples object of the study and for the profitable analysis and discussions of the results.

Contributor Information

Giuseppe Bonifazi, Email: giuseppe.bonifazi@uniroma1.it.

Riccardo Gasbarrone, Email: riccardo.gasbarrone@uniroma1.it.

Giuseppe Capobianco, Email: giuseppe.capobianco@uniroma1.it.

Silvia Serranti, Email: silvia.serranti@uniroma1.it.

References

  • 1.Zardetto S. Potential applications of near infrared spectroscopy for evaluating thermal treatments of fresh egg pasta. Food Control. 2005:249–256. doi: 10.1016/j.foodcont.2004.03.002. [DOI] [Google Scholar]
  • 2.Groß F., Benning R., Bindrich U., Franke K., Heinz V. Proceedings of the Procedia Food Science 11th International Congress on Engineering and Food (ICEF11) 2011. Optical online measurement technique used for process control of the drying step during pasta production; pp. 1301–1308. [DOI] [Google Scholar]
  • 3.Bevilacqua M., Bucci R., Materazzi S., Marini F. Application of near infrared (NIR) spectroscopy coupled to chemometrics for dried egg-pasta characterization and egg content quantification. Food Chem. 2013;140:726–734. doi: 10.1016/j.foodchem.2012.11.018. [DOI] [PubMed] [Google Scholar]
  • 4.Masoumi H., Safavi S.M., Khani Z. Identification and classification of plastic resins using near infrared reflectance spectroscopy. Int. J. Mech. Aerosp. Ind. Mechatron. Manuf. Eng. 2012;6(5):877–884. [Google Scholar]
  • 5.Bonifazi G., Gasbarrone R., Palmieri R., Serranti S. Near infrared hyperspectral imaging-based approach for end-of-life flat monitors recycling. Automatisierungstechnik. 2020;68(4):265–276. doi: 10.1515/auto-2019-0058. [DOI] [Google Scholar]
  • 6.Agresti G., Bonifazi G., Capobianco G., Lanteri L., Pelosi C., Serranti S., Veneri A. Hyperspectral imaging as powerful technique for evaluating the stability of Tattoo Wall®. Microchem. J. 2020;104866 doi: 10.1016/j.microc.2020.104866. [DOI] [Google Scholar]
  • 7.Bonifazi G., Capobianco G., Pelosi C., Serranti S. Hyperspectral imaging as powerful technique for investigating the stability of painting samples. J. Imaging. 2019;5(1):8. doi: 10.3390/jimaging5010008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Teixeira dos Santos C.A., Lopo M., Páscoa R.N.M.J., Lopes J.A. A review on the applications of portable near-infrared spectrometers in the agro-food industry. Appl. Spectrosc. 2013;67(11):1215–1233. doi: 10.1366/13-07228. [DOI] [PubMed] [Google Scholar]
  • 9.Kumaravelu C., Gopal A. Proceedings of the IEEE International Conference on Technological Innovations in ICT for Agriculture and Rural Development. 2015. A Review on the applications of near-infrared spectrometer and chemometrics for the agro-food processing industries. [Google Scholar]
  • 10.Serranti S., Bonifazi G., Gasbarrone R. Proceedings of the SPIE 10665, Sensing for Agriculture and Food Quality and Safety X, 106650R. 2018. Olive fruit ripening evaluation and quality assessment by hyperspectral sensing devices. [DOI] [Google Scholar]
  • 11.Serranti S., Bonifazi G., Gasbarrone R. Proceedings of the SPIE 10665, Sensing for Agriculture and Food Quality and Safety X, 106650S. 2018. Kiwifruits ripening assessment by portable hyperspectral devices. [DOI] [Google Scholar]
  • 12.Bonifazi G., Gasbarrone R., Serranti S. Proceedings of the SPIE 10986, Algorithms, Technologies, and Applications for Multispectral and Hyperspectral Imagery XXV, 109861S. 2019. Dried red chili peppers pungency assessment by visible and near infrared spectroscopy. [DOI] [Google Scholar]
  • 13.Tsuchikawa S., Kobori H. A review of recent application of near infrared spectroscopy to wood science and technology. J. Wood Sci. 2015;61:213–220. doi: 10.1007/s10086-015-1467-x. [DOI] [Google Scholar]
  • 14.Roggo Y., Chalus P., Maurer L., Lema-Martinez C., Edmond A., Jent N. A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies. J. Pharm. Biomed. Anal. 2007;44:683–700. doi: 10.1016/j.jpba.2007.03.023. [DOI] [PubMed] [Google Scholar]
  • 15.Larrechi M.S., Callao M.P. Strategy for introducing NIR spectroscopy and multivariate calibration techniques in industry. Trends Anal. Chem. 2003;22(10) doi: 10.1016/S0165-9936(03)01005-7. [DOI] [Google Scholar]
  • 16.Bonifazi G., Cardillo A., Currà A., Gasbarrone R., Serranti S. Proceedings of the SPIE 10662, Smart Biomedical and Physiological Sensor Technology XV, 106620O. 2018. Near infrared spectroscopy as a tool for in vivo analysis of human muscles. [DOI] [Google Scholar]
  • 17.Gasbarrone R., Currà A., Cardillo A., Bonifazi G., Serranti S. Proceedings of the SPIE 10489, Optical Biopsy XVI: Toward Real-Time Spectroscopic Imaging and Diagnosis, 1048914. 2018. Near infrared spectroscopy of human muscles. [DOI] [Google Scholar]
  • 18.Currà A., Gasbarrone R., Cardillo A., Trompetto C., Fattapposta F., Pierelli F., Missori P., Bonifazi G., Serranti S. Near infrared spectroscopy as a tool for in vivo analysis of human muscles. Sci. Rep. 2019;9:8623. doi: 10.1038/s41598-019-44896-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Pasquini C. Near infrared spectroscopy: fundamentals, practical aspects and analytical applications. J. Braz. Chem. Soc. 2003;14(2):198–219. doi: 10.1590/S0103-50532003000200006. [DOI] [Google Scholar]
  • 20.ASD Inc. FieldSpec®4 User Manual, ASD Document 600979 (2015).
  • 21.R. Gasbarrone 2020, FieldSpec4_Import3 (v.3.1). doi: 10.5281/zenodo.3776139. [DOI]
  • 22.Danner M., Locherer M., Hank T., Richter K. GFZ Data Services; 2015. Spectral Sampling With the ASD FieldSpec 4 –Theory, Measurement, Problems, Interpretation. EnMAP Field Guides Technical Report. [Google Scholar]

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES