Abstract
Aims
Target delineation uncertainty is arguably the largest source of geometric uncertainty in radiotherapy. Several factors can affect it, including the imaging modality used for delineation. It is accounted for by applying safety margins to the target to produce a planning target volume (PTV), to which treatments are designed. To determine the margin, the delineation uncertainty is measured as the delineation error, and then a margin recipe used. However, there is no published evidence of such analysis for recurrent gynaecological cancers (RGC). The aims of this study were first to quantify the delineation uncertainty for RGC gross tumour volumes (GTVs) and to calculate the associated PTV margins and then to quantify the difference in GTV, delineation uncertainty and PTV margin, between a computed tomography-magnetic resonance imaging (CT-MRI) and MRI workflow.
Materials and methods
Seven clinicians delineated the GTV for 20 RGC tumours on co-registered CT and MRI datasets (CT-MRI) and on MRI alone. The delineation error, the standard deviation of distances from each clinician's outline to a reference, was measured and the required PTV margin determined. Differences between using CT-MRI and MRI alone were assessed.
Results
The overall delineation error and the resulting margin were 3.1 mm and 8.5 mm, respectively, for CT-MRI, reducing to 2.5 mm and 7.1 mm, respectively, for MRI alone. Delineation errors and therefore the theoretical margins, varied widely between patients. MRI tumour volumes were on average 15% smaller than CT-MRI tumour volumes.
Discussion
This study is the first to quantify delineation error for RGC tumours and to calculate the corresponding PTV margin. The determined margins were larger than those reported in the literature for similar patients, bringing into question both current margins and margin calculation methods. The wide variation in delineation error between these patients suggests that applying a single population-based margin may result in PTVs that are suboptimal for many. Finally, the reduced tumour volumes and safety margins suggest that patients with RGC may benefit from an MRI-only treatment workflow.
Key words: Delineation uncertainty, planning target volume, radiotherapy, recurrent gynaecological cancer
Highlights
-
•
The first paper to focus on recurrent gynaecological tumour radiotherapy targets
-
•
Presents values for delineation error and the corresponding safety margins
-
•
Standard methods produce margins larger than those reportedly used elsewhere
-
•
Using MRI alone results in smaller target volumes than using CT and MRI together
Introduction
Radiotherapy, in combination with chemotherapy, has been recommended for the treatment of locoregional recurrence cervical and endometrial cancers in patients previously treated with radical surgery [[1], [2], [3], [4]]. This usually involves a combination of external beam radiotherapy to the pelvis followed by a boost to deliver a high dose to macroscopic disease with either brachytherapy or external beam radiotherapy if brachytherapy is not feasible. The tumour dose is often limited by the risk of toxicity due to close proximity to bowel, bladder and rectum.
Despite significant advances in radiotherapy techniques, geometric uncertainties persist in radiotherapy, with the largest arguably being the uncertainty in tumour delineation [[5], [6], [7]], here referred to as delineation uncertainty.
Radiotherapy treatments are based on a set of treatment volumes. First macroscopic disease is delineated on imaging as the gross demonstrable tumour mass, known as the gross tumour volume (GTV). From this, the clinical target volume (CTV) is derived, to account for potential microscopic spread, although when delivering external beam radiotherapy or brachytherapy boost for recurrent gynaecological cancers (RGC), the CTV may be the same as the GTV. Residual geometric uncertainties are then accounted for by adding safety margins to the CTV, resulting in the planning target volume (PTV), to which the treatment is planned.
A widely used method for calculating PTV margins is to use the van Herk margin recipe [8]. This requires each source of geometric uncertainty to be quantified, such as those associated with tumour delineation. According to that approach, failure to quantify these uncertainties can result in suboptimal PTVs and consequently treatments, where margins that are too small correspond with a lower than intended chance of the tumour receiving the planned dose, whereas margins that are too big result in unnecessary radiation dose to surrounding healthy tissue, which can lead to additional toxicities. For pelvic recurrence of gynaecological cancer, tumours can vary significantly between patients in volume, location and relation to the organs at risk. To the authors' knowledge, although required for PTV margin calculation, there is no published literature that quantifies the delineation uncertainty for RGC in a way that can be used for margin calculations. The use of different imaging modalities is known to affect the magnitude of delineation uncertainty [7,[9], [10], [11], [12]]. Due to the superior soft-tissue differentiation with magnetic resonance imaging (MRI) over computed tomography (CT), current practice is to delineate RGC GTVs using co-registered CT and MRI images, henceforth referred to as CT-MRI. Recent technological advances, such as MRI-only based treatment planning [13], are leading to the possibility of treatments based on MRI images alone.
The aims of this study were first to quantify delineation uncertainty for RGC GTVs and to calculate the associated PTV margins and then to quantify the difference in GTV, delineation uncertainty and PTV margin, between a CT-MRI and MRI workflow.
Materials and Methods
Delineation Study
A retrospective inter-observer variability study was carried out to quantify the GTV delineation uncertainty from patients with RGC in the central pelvis. This study was approved by the appropriate Institutional Review Board (SE433) and written informed consent was obtained from all subjects.
Twenty patients with RGC in the central pelvis, having previously had a hysterectomy, were retrospectively selected for this study on the basis of having a treatment GTV >10 cm3, and with both CT and MR images available.
CT scans were carried out on a 16-slice scanner, with a 2.5 mm slice separation for 17 of the patients, 1 mm for two patients and 1.3 mm for one patient. MRI scans were carried out on 1.5 Tesla scanners acquired at a range of institutions. All patients had a T2-weighted turbo spin echo sequence acquired axially, except for patient 13 who had a T2-weighted three-dimensional space sequence. MRI slice separations depended on the clinical need at the time of scanning, ranging from 3.0 to 6.0 mm (mean ± standard deviation = 4.5 ± 1.1 mm).
Seven clinicians from a single institution participated in the study: two radiologists and two radiation oncologists specialising in pelvic radiotherapy with at least 4 years' experience, and three radiation oncologists training in pelvic radiotherapy with 1–3 years' experience. Each clinician delineated the GTV on each of the patient scans using local clinical protocols.
To avoid the CT information biasing the MRI-only outlines, delineations were first performed on MRI alone, followed by CT-MRI registered using rigid registration applied to the local soft-tissue anatomy around the GTV. Registrations were carried out by an experienced medical physicist, and then reviewed by a consultant radiation oncologist. Each of the observers was blinded to all other delineations by having their own dedicated image dataset and password to the contouring software. Delineations were carried out on the Eclipse Treatment Planning System, version 13.6 (Varian Medical Systems, Palo Alto, CA, USA).
Delineation Error (ΣD)
To calculate the GTV–PTV margin required at each point, delineation uncertainty must be quantified as the delineation error (ΣD). This is the standard deviation of the distances from a reference outline to each outline. It is calculated using equation 1, where di is the distance from the reference outline to the ith observer's outline, No is the number of observers and is the mean distance. Although many metrics for measuring observer variability are used [7,14,15], ΣD is the only one that can be used in a traditional PTV margin recipe to calculate PTV margins.
| (1) |
To measure ΣD for each point in a patient, the approach taken by Deurloo et al. [16] was followed. First, the two-dimensional contour sets were converted to three-dimensional surfaces comprising of vertices and faces. A reference surface for each patient was then generated from all the clinician's GTV surfaces. This was carried out using the simultaneous truth and performance level estimation (STAPLE) algorithm [17] at a 95% confidence level. This produced a surface that encompasses voxels that have a 95% or more probability of belonging to the GTV based on the provided outlines. These consensus surfaces were generated using Computational Environment for Radiological Research (CERR) software module [18] implemented within MatLab (The MathWorks Inc., Natick, MA, USA).
For the jth vertex on the reference surface, the reference surface normal vector, nj, was determined. The distance along that normal vector to each comparator surface was then measured and equation 1 used to give the delineation error at the jth vertex ΣD,j. The result of this process is a three-dimensional surface map with potentially varying values of ΣD.
PTV margin recipes require summary ΣD values for each sector of the GTV corresponding to each of the cardinal axes. To determine which sector each vertex on the consensus surface belongs to, vector Kj, which originated at the centre of the consensus surface and terminated at vertex vj, was created. As were six vectors originating at the centre of the volume and pointing parallel to the patient left (), right (), anterior (), posterior (), superior () and inferior () axes. The angles between Kj and each of the vectors were then measured. Finally, the vertex vj was assigned to a single sector corresponding to the vector with the smallest angle to Kj. This process was repeated for each vertex on the consensus surface. Figure 1 illustrates the results for a spherical target. The approach of classifying the vertices in this way is similar to one taken in previous studies [[19], [20], [21]], however those publications only measured points along the cardinal planes, unlike this study where classifications and measurements were carried out for the whole surface.
Fig 1.
Illustrations of the vertex classifications for a spherical target as either left (blue), right (orange), anterior (purple), posterior (green), superior (yellow) or inferior (light blue). Arrows represent the axes from the centre of the volume. (A) is viewed from the superior axis, (B) from the left axis, (C) from the posterior axis and (D) is an oblique view.
The overall ΣD for a single patient was given by the geometric mean of ΣD, calculated over all vertices in that patient. The overall ΣD for all patients combined was then given by the geometric mean of ΣD from each patient. For values given for a single sector, these measurements and calculations were carried out for each sector separately. Pooling standard deviations in this way assumes that the variances between each group are equal; this assumption was tested using the methods described below. It was assumed that each case had an equal number of samples to avoid the largest GTVs dominating the value of ΣDs for all patients combined.
Gross Tumour Volume–Planning Target Volume Margin Calculation
The GTV–PTV margin, m, was calculated for each scenario using the van Herk margin recipe [8] shown in equation 2. This is based on ensuring the CTV, which is identical to the GTV in this case, is covered by the 80% isodose, as can be the case in stereotactic body radiotherapy, for 90% of the patients. Σ and σ are the combined standard deviation of all the systematic and random errors, respectively. Here it was assumed that daily image guidance was used and that random errors totalled 1 mm, as did systematic errors (excluding target delineation), based on a study by McNair et al. [22]. With this magnitude of random errors, the margins required for coverage by the 95% isodose would be 0.3 mm larger.
| (2) |
Statistical Analysis
The Wilcoxon signed rank test was used to compare differences in tumour volumes between CT-MRI and MRI. The Brown-Forsythe test was used to assess differences in the variance of the distances, ΣD2, between patients, imaging conditions and to determine the validity of pooling standard deviation data.
All tests were two-tailed and with significance level of 0.05. P-values were modified to compensate for multiple comparisons using the Bonferroni-Holm correction. All analyses and data processing were carried out in MatLab R2019a.
Results
The primary diagnosis for the 20 cases was: eight (40%) patients with carcinoma of the endometrium, five (25%) with cervical, four (20%) with vaginal and three (15%) with ovarian carcinoma. All patients had previously undergone surgery including total hysterectomy.
Gross Tumour Volumes
The mean and standard deviation of the GTV for each patient, taken over all observers, are illustrated in Figure 2, which shows a large range in volumes. The overall mean ± standard deviation was 57.0 ± 40.5 cm3 for CT-MRI and 48.5 ± 41.5 cm3 for MRI alone. MRI volumes were smaller than CT-MRI (P < 0.001), by an average of 15%.
Fig 2.
The mean gross tumour volume (GTV; bar height) and the standard deviation (error bars) for each patient, measured over all observers. Computed tomography–magnetic resonance imaging (CT-MRI) volumes are shown in blue, MRI only in orange. Patients are ordered by descending CT-MRI volume.
Delineation Error (ΣD) and PTV Margins (m)
The measured ΣD are presented in Table 1 for all patients combined. Overall, ΣD was smaller when using MRI alone relative to CT-MRI for both the whole surface and for each sector (P < 0.001). ΣD was significantly different within and between patients and sectors for both imaging conditions (P < 0.001). ΣD for each patient is illustrated in Figure 3, which also shows MRI ΣD to be smaller in 16 of the 20 cases compared with CT-MRI. The PTV margins resulting from the overall measured ΣD are also presented in Table 1. The overall ΣD and the resultant margins grouped by primary diagnosis are presented in Table 2. These are smaller for MRI relative to CT-MRI due to the smaller MRI measured ΣD irrespective of tumour volume.
Table 1.
Delineation error (ΣD) pooled over all patients and observers, measured over the whole surface and for each anterior (A), posterior (P), left (L), right (R), superior (S) and inferior (I) sectors. Resultant gross tumour volume–planning target volume (GTV–PTV) margins, m, are also presented. Values are shown for both computed tomography–magnetic resonance imaging (CT-MRI) and MRI alone
| Whole surface | Sector |
||||||
|---|---|---|---|---|---|---|---|
| A | P | L | R | S | I | ||
| ΣD (mm) CT-MRI |
3.1 | 2.7 | 2.6 | 2.8 | 3.0 | 3.2 | 3.6 |
| ΣD (mm) MRI |
2.5 | 2.0 | 2.4 | 2.2 | 2.6 | 3.0 | 2.7 |
| m (mm) CT-MRI |
8.5 | 7.6 | 7.4 | 7.8 | 8.3 | 8.8 | 9.7 |
| m (mm) MRI |
7.1 | 6.0 | 6.9 | 6.4 | 7.4 | 8.3 | 7.6 |
Fig 3.
Delineation error (ΣD) for each patient for both computed tomography–magnetic resonance imaging (CT-MRI; blue) and MRI alone (orange).
Table 2.
Delineation error (ΣD) and resultant gross tumour volume–planning target volume (GTV–PTV) margins, m, for patients grouped by primary diagnosis. Values are shown for both computed tomography–magnetic resonance imaging (CT-MRI) and MRI alone
| Primary diagnosis | ΣD (mm) |
m (mm) |
||
|---|---|---|---|---|
| CT-MRI | MRI | CT-MRI | MRI | |
| Ovary | 2.4 | 2.2 | 7.0 | 6.5 |
| Endometrium | 3.1 | 2.6 | 8.5 | 7.2 |
| Cervix | 2.7 | 2.0 | 7.6 | 6.0 |
| Vagina | 3.6 | 2.9 | 9.7 | 8.0 |
To illustrate the typical differences in outlines between observers, Figure 4 shows the CT-MRI outlines for patient 14, who had ΣD equal to the group median of 2.7 mm. The CT-MRI and MRI consensus STAPLE outlines are also shown, as are the PTVs grown from them.
Fig 4.
A selection of the outlines for patient 14; computed tomography–magnetic resonance imaging (CT-MRI) gross tumour volume (GTV) outlines from each observer are shown in red; CT-MRI GTV consensus outline is shown in yellow; MRI consensus outline is shown in green; CT-MRI planning target volume (PTV) is shown in orange; finally the MRI PTV is shown in turquoise. The locations of the viewing planes are indicated by the white arrows.
Discussion
This is the first paper to present an inter-observer variability study for RGC GTVs and to quantify the variability using the delineation error metric. These data are important as they are needed to calculate PTV margins using standard methods such as the van Herk margin recipe [8]. Our results provide a reference set of values against which other institutions can compare. Despite this benefit of measuring delineation error, few studies do so when performing inter-observer variability studies [7,15], making comparisons difficult. To give context to these results, the overall measured 3.1 mm delineation error is larger than the 2.0 mm for the prostate as measured by Alasti et al. [23] using CT alone, but is smaller than the average 5.5 mm value measured for the prostate bed by Ost et al. [24].
In addition to the delineation error varying between the sites of primary diagnosis, it also varied widely between patients, with ΣD ranging from 2.0 to 4.1 mm for CT-MRI and 1.5–4.3 mm for MRI. These values were found to be statistically different between patients, suggesting that the delineation error for this cohort is not sufficiently homogeneous to be accurately combined into an overall value. These results bring into question whether population-based GTV–PTV margins are appropriate for RGC GTVs. Using population-based margins for these patients will likely result in target volumes that are either too large or too small for many patients. These patients will probably benefit from a more personalised approach to account for delineation uncertainty, for example through performing an inter-observer variability study for each patient. However, this is unlikely to be feasible in a clinical setting. An alternative solution, developed by Bernstein et al. [33], derives personalised PTVs from outlines produced by a single clinician. One of the few studies that assess this variation between patients is Steenbakkers et al. [25], who reported the delineation error to range from 1.9 to 7.5 mm for lung GTVs based on CT-PET images. In our study, the variation in MRI resolution between patients, primarily in the axial slice separation, is probably responsible for some of the variation seen between patients. Using consistent MRI parameters with high resolution is likely to improve consistency, delineation error and reduce superior–inferior PTV margins. However, it is unlikely to affect the findings in this study, particularly when considering that the delineation error was of a similar magnitude axially and varied significantly between patients.
The overall CT-MRI margin of 8.5 mm is larger than the margins reported in the literature for RGC, or similar, treatment sites. For example, Dewas et al. [26] reported using 3 mm GTV–PTV margins for lateral pelvic recurrences. A publication by Park et al. [27], which reported on the experience of three centres in Korea treating recurrent or oligometastatic uterine cervix cancer patients, reported all centres also using 3 mm margins, as did Kunos et al. [28], who reported the use of 3 mm margins in a phase II trial of metastatic gynaecological malignancies. A publication by Hasan et al. [29] into the treatment of recurrent gynaecological malignancies reported using 3 mm margins in most patients, albeit with a range of 0–5 mm. These publications did not state how their margins were determined. However, to achieve a margin of 3 mm using the van Herk margin recipe would require a ΣD of approximately 1 mm. Yet, the smallest value seen for ΣD in this study evaluating 20 patients was 2 mm for CT-MRI.
Although this study focused on external beam radiotherapy, the delineation uncertainty and variability shown is probably also present for brachytherapy treatments. In brachytherapy, GTV–PTV margins are not routinely used, therefore these uncertainties may have a detrimental impact on brachytherapy treatments.
The use and consequences of inadequate margins in the pelvis has been reported by Engels et al. [30] for patients with prostate cancer. The authors reported significantly worse 5-year freedom from biochemical failure in patients treated with 3–5 mm PTV margins than those treated with 6–10 mm margins, highlighting the importance of optimal target coverage. The effect of inadequate PTV margins on clinical outcomes in patients with RGC warrants further investigation.
To assess the potential benefit of recent technological developments, such as synthetic CT, as described by Johnstone et al. [31], the impact of RGC GTV delineation on MRI alone was compared with CT-MRI. MRI-based tumour volumes were smaller for most patients, by an average of 15%. This is similar to the 10% and 18% found by Alasti et al. [23] and Gunnlaugsson et al. [32] respectively for the prostate when using MRI alone. RGC GTV delineation error was also smaller, by 0.6 mm overall, which translated into a smaller PTV margin. In comparison, Alasti et al. [23] measured a 0.2 mm delineation error reduction for the prostate. One possible explanation for this is anatomical changes between the two scans, for example due to target and/or organ at risk movement, leading to differences in GTV boundary position between the two images, imperfect registration and ultimately increasing uncertainty when using multiple scans. Assuming no significant geometric uncertainties are introduced by an MRI-only workflow, the combination of smaller volumes and lower delineation error would result in smaller PTVs.
In conclusion, this study is the first to quantify delineation error for RGC GTVs. Presenting the inter-observer variability in terms of delineation error has allowed the PTV margins to be calculated, which are larger than those reported in the literature for similar disease sites. A wide range in delineation error was found between patients, which corresponded to a wide range in the theoretical GTV-PTV margins, suggesting that one margin for all cases is unlikely to be a viable strategy. Finally, the smaller delineation error and GTVs suggest that patients with RGC may benefit from an MRI-only treatment workflow. This study highlights the need for further research into the PTV margins and imaging modalities used for patients with RGC treated with radiotherapy.
Conflicts of interest
The authors declare no conflicts of interest.
Acknowledgements
This publication presents independent research part funded by the National Institute for Health Research (NIHR, HCS DRF-2014-05-005). This research was also part funded by the NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research. Research at The Institute of Cancer Research is also supported by Cancer Research UK under Programme C33589/A19727. The views expressed are those of the author(s) and not necessarily those of the National Health Service, the NIHR or the Department of Health.
References
- 1.Friedlander M., Grogan M. Guidelines for the treatment of recurrent and metastatic cervical cancer. Oncologist. 2002;7:342–347. [PubMed] [Google Scholar]
- 2.Gadducci A., Tana R., Cosio S., Cionini L. Treatment options in recurrent cervical cancer. Oncol Lett. 2010;1:3–11. doi: 10.3892/ol_00000001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Peiretti M., Zapardiel I., Zanagnolo V., Landoni F., Morrow C.P., Maggioni A. Management of recurrent cervical cancer: a review of the literature. Surg Oncol. 2012;21:e59–e66. doi: 10.1016/j.suronc.2011.12.008. [DOI] [PubMed] [Google Scholar]
- 4.Bradford L.S., Rauh-Hain J.A., Schorge J., Birrer M.J., Dizon D.S. Advances in the management of recurrent endometrial cancer. Am J Clin Oncol. 2015;38:206–212. doi: 10.1097/COC.0b013e31829a2974. [DOI] [PubMed] [Google Scholar]
- 5.Njeh C.F. Tumor delineation: the weakest link in the search for accuracy in radiotherapy. J Med Phys. 2008;33:136–140. doi: 10.4103/0971-6203.44472. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Thwaites D. Accuracy required and achievable in radiotherapy dosimetry: have modern technology and techniques changed our views? J Phys Conf Ser. 2013;444 [Google Scholar]
- 7.Segedin B., Petric P. Uncertainties in target volume delineation in radiotherapy – are they relevant and what can we do about them? Radiol Oncol. 2016;50:254–262. doi: 10.1515/raon-2016-0023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.van Herk M., Remeijer P., Rasch C., Lebesque J.V. The probability of correct target dosage: dose–population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47:1121–1135. doi: 10.1016/s0360-3016(00)00518-6. [DOI] [PubMed] [Google Scholar]
- 9.Ahmed M., Schmidt M., Sohaib A., Kong C., Burke K., Richardson C. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours – a study using flexible surface coils. Radiother Oncol. 2010;94:161–167. doi: 10.1016/j.radonc.2009.12.021. [DOI] [PubMed] [Google Scholar]
- 10.Gerlich A.S., van der Velden J.M., Kotte A.N.T.J., Tseng C.L., Fanetti G., Eppinga W.S.C. Inter-observer agreement in GTV delineation of bone metastases on CT and impact of MR imaging: a multicenter study. Radiother Oncol. 2018;126:534–540. doi: 10.1016/j.radonc.2017.08.030. [DOI] [PubMed] [Google Scholar]
- 11.Bird D., Scarsbrook A.F., Sykes J., Ramasamy S., Subesinghe M., Carey B. Multimodality imaging with CT, MR and FDG-PET for radiotherapy target volume delineation in oropharyngeal squamous cell carcinoma. BMC Cancer. 2015;15:844. doi: 10.1186/s12885-015-1867-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Vinod S.K., Min M., Jameson M.G., Holloway L.C. A review of interventions to reduce inter-observer variability in volume delineation in radiation oncology. J Med Imaging Radiat Oncol. 2016;60:393–406. doi: 10.1111/1754-9485.12462. [DOI] [PubMed] [Google Scholar]
- 13.Owrangi A.M., Greer P.B., Glide-Hurst C.K. MRI-only treatment planning: benefits and challenges. Phys Med Biol. 2018;63 doi: 10.1088/1361-6560/aaaca4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Fotina I., Lütgendorf-Caucig C., Stock M., Pötter R., Georg D. Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy. Strahlenther Onkol. 2012;188:160–167. doi: 10.1007/s00066-011-0027-6. [DOI] [PubMed] [Google Scholar]
- 15.Vinod S.K., Jameson M.G., Min M., Holloway L.C. Uncertainties in volume delineation in radiation oncology: a systematic review and recommendations for future studies. Radiother Oncol. 2016;121:169–179. doi: 10.1016/j.radonc.2016.09.009. [DOI] [PubMed] [Google Scholar]
- 16.Deurloo K.E.I., Steenbakkers R.J.H.M., Zijp L.J., de Bois J.A., Nowak P.J.C.M., Rasch C.R.N. Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy. Int J Radiat Oncol Biol Phys. 2005;61:228–238. doi: 10.1016/j.ijrobp.2004.09.023. [DOI] [PubMed] [Google Scholar]
- 17.Warfield S.K., Zou K.H., Wells W.M. Simultaneous truth and performance level estimation (STAPLE): an algorithm for the validation of image segmentation. IEEE Trans Med Imaging. 2004;23:903–921. doi: 10.1109/TMI.2004.828354. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Deasy J.O., Blanco A.I., Clark V.H. CERR: a computational environment for radiotherapy research. Med Phys. 2003;30:979–985. doi: 10.1118/1.1568978. [DOI] [PubMed] [Google Scholar]
- 19.Gao Z., Wilkins D., Eapen L., Morash C., Wassef Y., Gerig L. A study of prostate delineation referenced against a gold standard created from the visible human data. Radiother Oncol. 2007;85:239–246. doi: 10.1016/j.radonc.2007.08.001. [DOI] [PubMed] [Google Scholar]
- 20.Petric P., Hudej R., Rogelj P., Blas M., Tanderup K., Fidarova E. Uncertainties of target volume delineation in MRI guided adaptive brachytherapy of cervix cancer: a multi-institutional study. Radiother Oncol. 2013;107:6–12. doi: 10.1016/j.radonc.2013.01.014. [DOI] [PubMed] [Google Scholar]
- 21.Seppala T., Visapaa H., Collan J., Kapanen M., Beule A., Kouri M. Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer: a comparison between two modalities. Strahlenther Onkol. 2015;191:862–868. doi: 10.1007/s00066-015-0868-5. [DOI] [PubMed] [Google Scholar]
- 22.McNair H.A., Hansen V.N., Parker C.C., Evans P.M., Norman A., Miles E. A comparison of the use of bony anatomy and internal markers for offline verification and an evaluation of the potential benefit of online and offline verification protocols for prostate radiotherapy. Int J Radiat Oncol Biol Phys. 2008;71:41–50. doi: 10.1016/j.ijrobp.2007.09.002. [DOI] [PubMed] [Google Scholar]
- 23.Alasti H., Cho Y.-B., Catton C., Berlin A., Chung P., Bayley A. Evaluation of high dose volumetric CT to reduce inter-observer delineation variability and PTV margins for prostate cancer radiotherapy. Radiother Oncol. 2017;125:118–123. doi: 10.1016/j.radonc.2017.08.012. [DOI] [PubMed] [Google Scholar]
- 24.Ost P., De Meerleer G., Vercauteren T., De Gersem W., Veldeman L., Vandecasteele K. Delineation of the postprostatectomy prostate bed using computed tomography: interobserver variability following the EORTC delineation guidelines. Int J Radiat Oncol Biol Phys. 2011;81:e143–e149. doi: 10.1016/j.ijrobp.2010.12.057. [DOI] [PubMed] [Google Scholar]
- 25.Steenbakkers R.J.H.M., Duppen J.C., Fitton I., Deurloo K.E.I., Zijp L.J., Comans E.F.I. Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis. Int J Radiat Oncol Biol Phys. 2006;64:435–448. doi: 10.1016/j.ijrobp.2005.06.034. [DOI] [PubMed] [Google Scholar]
- 26.Dewas S., Bibault J.E., Mirabel X., Nickers P., Castelain B., Lacornerie T. Robotic image-guided reirradiation of lateral pelvic recurrences: preliminary results. Radiat Oncol. 2011;6:77. doi: 10.1186/1748-717X-6-77. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Park H.J., Chang A.R., Seo Y., Cho C.K., Jang W.I., Kim M.S. Stereotactic body radiotherapy for recurrent or oligometastatic uterine cervix cancer: a cooperative study of the Korean Radiation Oncology Group (KROG 14-11) Anticancer Res. 2015;35:5103–5110. [PubMed] [Google Scholar]
- 28.Kunos C.A., Brindle J., Waggoner S., Zanotti K., Resnick K., Fusco N. Phase II clinical trial of robotic stereotactic body radiosurgery for metastatic gynecologic malignancies. Front Oncol. 2012;2:181. doi: 10.3389/fonc.2012.00181. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Hasan S., Ricco A., Jenkins K., Lanciano R., Hanlon A., Lamond J. Survival and control prognosticators of recurrent gynecological malignancies of the pelvis and para-aortic region treated with stereotactic body radiation therapy. Front Oncol. 2016;6:249. doi: 10.3389/fonc.2016.00249. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Engels B., Soete G., Verellen D., Storme G. Conformal arc radiotherapy for prostate cancer: increased biochemical failure in patients with distended rectum on the planning computed tomogram despite image guidance by implanted markers. Int J Radiat Oncol Biol Phys. 2009;74:388–391. doi: 10.1016/j.ijrobp.2008.08.007. [DOI] [PubMed] [Google Scholar]
- 31.Johnstone E., Wyatt J.J., Henry A.M., Short S.C., Sebag-Montefiore D., Murray L. Systematic review of synthetic computed tomography generation methodologies for use in magnetic resonance imaging-only radiation therapy. Int J Radiat Oncol Biol Phys. 2018;100:199–217. doi: 10.1016/j.ijrobp.2017.08.043. [DOI] [PubMed] [Google Scholar]
- 32.Gunnlaugsson A., Persson E., Gustafsson C., Kjellén E., Ambolt P., Engelholm S. Target definition in radiotherapy of prostate cancer using magnetic resonance imaging only workflow. Phys Imaging Radiat Oncol. 2019;9:89–91. doi: 10.1016/j.phro.2019.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Bernstein D., Taylor A., Nill S., Oelfke U. New target volume delineation and PTV strategies to further personalise radiotherapy. Phys Med Biol. 2021;66:055024. doi: 10.1088/1361-6560/abe029. [DOI] [PMC free article] [PubMed] [Google Scholar]




