Abstract
Mechanotransduction, the encoding of local mechanical stresses and strains at sensory endings into neural action potentials at the viscera, plays a critical role in evoking visceral pain, e.g., in the distal colon and rectum (colorectum). The wall of the colorectum is structurally heterogeneous, including two major composites: the inner consists of muscular and submucosal layers, and the outer consists of circular muscular, intermuscular, longitudinal muscular, and serosal layers. In fact the colorectum presents biomechanical heterogenity across both the longitudinal and through-thickness directions thus highlighting the differential roles of sensory nerve endings within different regions of the colorectum in visceral mechanotransduction. We determined constitutive models and model parameters for individual layers of the colorectum from three longitudinal locations (colonic, intermediate, and distal) using nonlinear optimization to fit our experimental results from biaxial extension tests on layer-separated colorectal tissues (mouse model, 7 × 7 mm2, Siri et al., Am. J. Physiol. Gastrointest. Liver Physiol. 316, G473-G481 and 317, G349-G358), and quantified the thicknesses of the layers. In this study we also quantified the residual stretches stemming from separating colorectal specimens into inner and outer composites and we completed new pressure-diameter mechanical testing to provide an additional validation case. We implemented the constitutive equations and created two-layered, 3-D finite element models using FEBio (University of Utah), and incorporated the residual stretches. We validated the modeling framework by comparing FE-predicted results for both biaxial extension testing of bulk specimens of colorectum and pressure-diameter testing of bulk segments against corresponding experimental results independent of those used in our model fitting. We present the first theoretical framework to simulate the biomechanics of distal colorectum, including both longitudinal and through-thickness heterogeneity, based on constitutive modeling of biaxial extension tests of colon tissues from mice. Our constitutive models and modeling framework facilitate analyses of both fundamental questions (e.g., the impact of organ/tissue biomechanics on mechanotransduction of the sensory nerve endings, structure-function relationships, and growth and remodeling in health and disease) and specific applications (e.g., device design, minimally invasive surgery, and biomedical research).
Keywords: Colorectum, Biomechanics, Constitutive Modeling, Finite Element Modeling, Mechanotransduction
1. Introduction
Visceral pain is the cardinal complaint of patients with irritable bowel syndrome (IBS), a condition that affects over 15% of the U.S. population (Cervero and Laird, 1999). Visceral pain registers in the brain but usually initiates from sensory nerve endings embedded in visceral organs. IBS-related visceral pain originates from the distal colon and rectum (colorectum). Unlike sensory endings at the skin that encode various stimuli (e.g., thermal, mechanical, chemical), visceral sensory endings bias heavily towards encoding of mechanical stimuli, in fact 70–80% of all colorectal sensory endings are mechanosensitive (Pasricha et al., 2006; Zhao et al., 2019). Correspondingly, clinical evidence indicates that it is mechanical distension and cramping of hollowing visceral organs, not even burning or inflammation, that reliably evokes pain from the viscera (Clarke et al., 2009; Camilleri et al., 2017).
Mechanotransduction, the encoding of local mechanical stresses and strains at sensory endings into neural action potentials at the viscera, plays a critical role in evoking visceral pain. The wall of the colorectum is structurally heterogeneous, including two major composites. The inner composite consists of muscular and submucosal layers, and the outer composite consists of circular muscular, intermuscular, longitudinal muscular, and serosal layers. The two composites are loosely connected at an interstitial space between the submucosa and circular muscular layers. The intra-tissue biomechanics of visceral organs govern the relationship between macroscopic mechanical organ stimuli and local mechanical stresses and strains at sensory endings, knowledge of which may further advance our mechanistic understanding of visceral mechanotransduction and visceral pain in patients (Feng and Gebhart, 2010; Feng et al., 2012, 2013).
Knowledge of the biomechanics of the distal gastrointestinal tract is limited, in sharp contrast to the plethora of data regarding the neurophysiology of visceral sensory nerve endings embedded the colorectum (Feng and Gebhart, 2010; Feng et al., 2010, 2013; Kiyatkin et al., 2013; Feng and Gebhart, 2015; Feng et al., 2015). Previous researchers quantified the biomechanical properties of human colonic tissues (Watters et al., 1985b; Egorov et al., 2002; Howes and Hardy, 2012; Massalou et al., 2016), as well as colonic tissues derived from animal models used as surrogates (Jiminez et al., 2015) including goats (Higa et al., 2007), pigs (Qiao et al., 2005; Carniel et al., 2015; Patel et al., 2018; Puértolas et al., 2020), and mice (Watters et al., 1985a; Sokolis and Sassani, 2013; Gong et al., 2017; Siri et al., 2019a,b). These studies, using various mechanical tests in tension, compression, and shear, identified colon tissues as both nonlinear and anisotropic under large strains.
Constitutive models for colon tissues are rare, particularly those motivated by, and calibrated and validated with, experimental results. Ciarletta et al. (2009) applied a hyperelastic constitutive model to fit the passive mechanical responses of porcine intestine. They decoupled their strain-energy function into isotropic and anisotropic contributions, the later describing four exponentially stiffening families of fibers (longitudinally and circumferentially aligned muscle, and two diagonally and symmetrically aligned collagen), cf. Ferruzzi et al. (2011). This model, fitted to uniaxial tension and shear tests of porcine intestine, accurately reproduced the mechanical measurements and demonstrated clearly the fundamental mechanical role of collagen architecture in the passive biomechanics of intestinal walls. Sokolis and Sassani (2013) fitted a range of hyperelastic constitutive models to passive mechanical data generated from tubular specimens of ascending, mid, and descending colons, and rectums of rats. A model including the neo-Hookean plus three families of exponentially stiffening fibers (two diagonally symmetric plus one axial) accurately fitted the multiaxial response of the intestinal wall and did not suffer from problems with over parameterization. Therein, the mid colon region was the stiffest, consistent with its higher collagen content relative to the distal regions.
More recently, Patel et al. (2018) proposed a constitutive model for the passive mechanical behavior of swine colon, and accounted for residual strains based on measurements of the opening angle. They again used an additive decomposition of the strain-energy function into isotropic and anisotropic contributions, the later describing four exponentially stiffening families of fibers (perfectly aligned longitudinally and circumferentially, and two dispersed families principally aligned diagonally and symmetrically, cf. Gasser et al. (2006). This model accurately captured the passive inflation-extension of both spiral and descending colon of swine, and revealed that the submucosa layer carries the passive circumferential load, not the circumferential muscle layer. Puértolas et al. (2020) measured the biomechanical responses of colonic tissues using biaxial extension tests of porcine colon from several longitudinal locations. They fitted these data using both discrete-fiber (with two to four families of fibers) and ODF-based (Microfiber von Mises Model (MFM) model and Microfiber Bingham Model (MFB)) constitutive models. The two ODF-based constitutive models both required five parameters, and of these the MFM model showed better predictive power. While all models fit the mechanical data reasonably well, the discrete four-fiber-family model presented the best predictive capability overall.
Toward understanding the impact of organ/tissue biomechanics on mechanotransduction of the sensory nerve endings in the colon and rectum (Feng et al., 2015), we recently performed biaxial extension tests on specimens of colorectum from mice, which including both the bulk composite (Siri et al., 2019a) and the layer-separated inner and outer composites individually (Siri et al., 2019b). Our results indicated strong mechanical heterogeneity both in the longitudinal direction (i.e., differences among colonic, intermediate, and rectal segments) and through the wall-thickness (i.e., between the inner and outer composites). To quantify the residual stretches we also determined the so called ‘opening-angles’ for bulk composite tissue.
We also probed the micromechanics of the colorectum by imaging the network of collagen fibers through the thickness of the wall. By analyzing through-thickness images acquired with second-harmonic generation (SHG) confocal microscopy we quantified the principal orientation of collagen (and muscle) fibers throughout the colorectum. Our results reveal a concentrated fiber network in the submucosa, consisting of two families of aligned fibers oriented approximately ±60% from the circumferential direction (Siri et al., 2019a). Our recent experimental data on the macro- and micro-mechanics of the colorectum strongly indicates that the submucosa functions as the primary loading-bearing structure of the colorectum.
In this study we aimed to leverage our experimental evidence to establish, calibrate, and validate constitutive models to reproduce and predict the heterogeneous biomechanics of the colorectum and better predict intra-tissue distributions of strains and stresses. We determined the model parameters for individual layers of the colorectum using nonlinear optimization to fit our experimental results from biaxial extension tests on layer-separated colorectal tissues (mouse model, 7 × 7 mm2), and quantified the residual stretches. We implemented the constitutive equations and created two-layered, 3-D finite element (FE) models using FEBio (University of Utah), and incorporated the residual stretches. We validated the modeling framework by comparing FE-predicted results for both biaxial extension testing of bulk specimens of colorectum and pressure-diameter testing of bulk segments against corresponding experimental results independent of those used in our model fitting. Such constitutive models, applied to FE analyses of the intra-tissue biomechanics of the colorectum, will complement our knowledge of visceral afferent neurophysiology to synergistically advance our mechanistic understanding of visceral mechanotransduction.
2. Materials and Methods
2.1. Experimental Evidence on the Colorectum
We recently completed and published biaxial extension mechanical testing on both bulk and layer-separated colorectal tissues, as well as imaging via second harmonic generation (SHG) to quantify the thicknesses of the layers and the microstructure (Siri et al., 2019a,b). In this study we also quantified the residual stretches stemming from separating colorectal specimens into inner and outer composites and we completed new pressure-diameter mechanical testing to provide an additional validation case for our modeling framework. All experiments use the same mouse model, mice of 8–16 weeks in age and 20–30g in weight (C57BL/6, Taconic, Germantown, NY).
2.1.1. Biaxial Extension Testing of Bulk Composite and Separated Layers
We recently performed biaxial extension tests on square specimens (7 × 7 mm2) harvested from multiple locations along the colorectum (colonic, intermediate, and rectal) and tested these as both the bulk composite (the whole wall) and the layer-separated inner and outer composites (Siri et al., 2019a,b). Briefly, following Siri et al. (2019a), we harvested the distal 30mm of the colorectum from a cohort of mice, divided evenly into three 10-mm-long segments (colonic, intermediate, and rectal), and conducted biaxial extension tests for each bulk composite segment. Briefly, following (Siri et al., 2019b), we harvested the distal 30mm of the colorectum from a different cohort of mice and dissected this tissue into inner and outer composite layers. The inner composite included the mucosa and submucosa, whereas the outer composite included the muscular layers and serosa. We divided each composite axially into three 10-mm-long segments and conducted biaxial extension tests for each inner and outer composite segment. Our results revealed that the stiffness of the inner composite in the longitudial (axial) direction is approximately twice that in the circumferential direction. Analyzing these data we determined the biaxial Cauchy stress-stretch behavior for both the bulk composite and the layer-separated inner and outer composites from colonic, intermediate, and rectal locations along the colorectum.
2.1.2. SHG Imaging of Specific Layers
We recently determined, by nonlinear imaging via SHG, both the layer thicknesses for each distinct layer across the thickness of the colorectal wall and the principal orientations of collagen or muscle fibers (Siri et al., 2019a,b). We report the thicknesses of the inner and outer composite layers of the colorectum segments in the load-free, reference configuration as Means ± Standard Deviations (M±SD) in Table 1.
Table 1:
Measurements of the thicknesses of the inner and outer composite layers of segments of the colorectum (M ± SD), cf. Siri et al. (2019b).
Segment | Inner (μm) | Outer (μm) |
---|---|---|
Colonic (n = 8) | 87.16±28.68 | 48.88±25.31 |
Intermediate (n = 7) | 107.17±26.40 | 45.57±17.96 |
Rectal (n = 7) | 113.28±20.18 | 79.43±34.33 |
The thickness of the submucosa measured by SHG showed no difference from proximal to distal colorectum in the load-free reference configuration, which likely contributes to the comparable stiffness of the inner composite along the colorectum. Furthermore, the serosa in the outer composite showed a membrane-like thin structure unlikely to make significant contributions to the overall mechanical stiffness of the bulk composite colorectum.
Our SHG results also revealed a rich collagen network in the submucosa often oriented approximately ±60° to the circumferential direction, consistent with results from the biaxial extension test presenting approximately twice the stiffness in longitudinal direction versus the circumferential direction.
2.1.3. Quantifying Layer-Separated Residual Deformations
To quantify the layer-separated residual deformations we harvested the distal 30mm of the colorectum from 11 mice following a procedure detailed previously (Siri et al., 2019a,b). We then divided these specimens evenly into three 10-mm-long segments (colonic, intermediate, and rectal), and harvested square specimens (7 × 7 mm2) from each of the three segments. We then carefully separated each specimen into inner and outer composites by fine blunt dissection using the interstitial space below the submucosa. Finally, we measured the dimensions of the separated composites using a caliper, and determined the mean ± the standard deviation of the circumferential lengths.
2.1.4. Pressure-Diameter Testing of Bulk Composite
We performed a pressure-diameter tests on bulk (intact) tubular segments of colorectum. We harvested the distal 30mm of the colorectum from four mice following a procedure detailed previously (Siri et al., 2019a,b). We cannulated each specimen within a custom-built chamber and in a bath of phosphate-buffered saline including nifedipine (4 μM; L-type calcium channel antagonist to block muscle activities), penicillin-streptomycin (100 U/ml), and protease inhibitors (P-2714, Sigma-Aldrich, St. Louis, MO). We then varied the intraluminal pressure from 10 to 100mmHg (1.33 to 13.3 kPa) using a syringe pump (NE-1000, New Era Pump Systems, Farmingdale, NY) connected to the proximal end of the colon. We recorded images of the lateral expansion of the tubular segment using a stereo-camera system with two five-megapixel cameras (Manta G-505, Allied Vision, Stadtroda, DE) for subsequent analyses. Finally, we measured the outer diameter of the colon within the colonic, intermediate, and rectal segments as a function of pressure using ImageJ (National Institutes of Health, Bethesda, MD), and determined the mean ± the standard deviation of the outer diameter.
2.2. Constitutive Modeling and Model Fitting
We described the colorectum as a multi-layered, soft elastic continuum deforming such that the deformation gradient is F. We used a multiplicative split of the strain-energy function Ψ into volumetric and isochoric contributions as , where U(J) = κ(J − 1)2/2, J = det F (the Jacobian of the deformation gradient), and κ is a nonphysical, positive penalty parameter used to enforce near incompressibility. We also used the multiplicative decomposition , and similarly the isochoric right Cauchy-Green tensor , where C = FTF.
To model the individual mechanical responses of the inner and outer composites of colorectum wall we specify as
(1) |
where we specified as an isotropic (neo-Hookean) matrix , where μ > 0 is a stress-like material parameter (corresponding to the shear modulus of the underlying matrix material in the reference configuration), is the first invariant of , and we specify , the contribution from the fiber network, as (Holzapfel et al., 2014; Pierce et al., 2016)
(2) |
where k1 > 0 is a stress-like material parameter, k2 > 0 is a dimensionless parameter, is the isochoric fourth pseudo-invariant of M (the reference angular orientation of a single fiber), and is a Heaviside function evaluated at , i.e., the collagen fibers do not support compression. Finally, ρ(M) is an orientation distribution function (ODF) characterizing the angular density of the fiber network with 1/4 ∫Ω ρ(M)dΩ = 1, where is the unit sphere.
We specify ρ(M) in a form inspired by, and measurable with, diffusion tensor magnetic resonance imaging (DT-MRI) which determines a second-order, symmetric, positive-definite tensor D. Given the diffusion tensor
(3) |
where θ, z, and r are the local circumferential, longitudinal, and radial directions within the colorectum. The ODF then follows as (Pierce et al., 2016)
(4) |
See appendix A for more details.
To capture the kinematics of the biaxial extension test, and neglecting shear deformations, we wrote the invariants I1 = trC and I4 = M · CM in terms of the stretches in the biaxial extension test, i.e., as
(5) |
and
(6) |
where λθ and λz are the measured stretches in the circumferential and longitudinal directions respectively, (considering incompressibility), and α is the angle between the principal fiber orientation and the circumferential direction such that Dθθ = cos α, Dzz = sin α, and Drr = Dθz = Dzr = Dθr = 0 in (3). Considering the Cauchy stresses in the circumferential and longitudinal directions respectively as σθθ = λθ(∂Ψ/∂λθ), and σzz = λz(∂Ψ/∂λz), and by enforcing incompressibility (λθ λz λr = 1), we expressed these Cauchy stresses as
(7) |
and
(8) |
where Ψi = ∂Ψ/∂Ii, i = (1, 4).
We simultaneously fit the experimental data for each layer-separated specimen at each location (Section 2.1.1) with the constitutive model, (1)–(4), using the optimation toolbox ‘lsqnonlin’ in MATLAB (V2019, Mathworks, MA). Consequently, we obtained four model parameters (μ, k1, k2, α) from each fitting.
2.3. Validating the Model
We systematically validated the predictive power of our constitutive models by comparing results from FE analyses of (a) biaxial extension tests of the reconstructed bulk composite (7 × 7 mm2) and (b) pressure-diameter tests of the intact (tubular) colorectum, both shown in Fig. 1, against corresponding, independent experimental measurements. In both FE analyses we specified the layer thicknesses at each longitudinal location based on Table 1 and we incorporated residual stretches/stresses based on Table 2, and implemented the latter using the prestrain algorithm implemented within FEBio (R2.8.5, University of Utah, UT) (Maas et al., 2012). We complete all simulations in using FEBio.
Figure 1:
Finite element analyses used for validation: (a) biaxial extension test of the bulk composite (two-layered) coloretum and (b) pressure-diameter test of the intact (tubular) colorectum.
Table 2:
Measurements of the circumferential length after layer-separation of the colorectum segments (M ± SD).
Segment | Bulk (mm) | Inner (mm) | Outer (mm) |
---|---|---|---|
Colonic (n = 10) | 7.000 | 7.123±0.028 | 6.832±0.051 |
Intermediate (n = 11) | 7.000 | 7.145±0.025 | 6.792±0.054 |
Rectal (n = 11) | 7.000 | 7.135±0.029 | 6.684±0.049 |
2.3.1. Biaxial Extension Testing of Bulk Composite
To simulate the biaxial extension tests, we modeled bulk composite specimens of colorectum as two-layered, residually stressed square patches. Exploiting symmetry boundary conditions we established a two-layered square patch of colorectal tissue (3.5 × 3.5 mm2) which we meshed using 2000 hexahedral elements, see Fig. 1(a). To model the biaxial extension tests, we linearly increased the circumferential and longitudinal (axial) displacements simultaneously.
2.3.2. Pressure-Diameter Testing of Bulk Composite
To simulate colorectal distensions, we modeled intact (bulk composite) colorectums as two-layered, residually stressed tubular segments. We applied symmetry boundary conditions on both faces of the model normal to the longitudinal direction, fixed to radial rows of nodes normal to the radial direction (preventing rigid-body rotations, see Fig. 1(b)), and stretched the model axially by 30%, consistent with the experiment ex vivo. Exploiting plane-strain conditions we established segments of intact, two-layered colorectums which we meshed using 1024 hexahedral elements, see Fig. 1(b). To model the ex vivo pressure-diameter tests we linearly increased the intraluminal pressure from 0 to 100 mmHg.
3. Results
3.1. Experimental Evidence on the Colorectum
3.1.1. Quantifying Layer-Separated Residual Deformations
We present the composite (reference) and separated (current configuration) circumferential lengths as Means ± Standard Deviations (M±SD) in Table 2.
3.1.2. Pressure-Diameter Testing of Bulk Composite
We present the outer diameters of four bulk-composite tubular specimens of colorectum as a function internal pressure as Means ± Standard Deviations (M±SD) in Table 3.
Table 3:
Measurements of the outer diameters of four bulk-composite tubular specimens of colorectum as a function internal pressure during pressure-diameter testing (M ± SD).
Pressure (mmHg) | Specimen 1 (mm) | Specimen 2 (mm) | Specimen 3 (mm) | Specimen 4 (mm) |
---|---|---|---|---|
10 | 3.911±0.041 | 3.504±0.034 | 3.237±0.060 | 2.599±0.024 |
25 | 4.603±0.043 | 4.293±0.070 | 4.001±0.033 | 3.042±0.051 |
50 | 4.920±0.022 | 4.724±0.064 | 4.405±0.041 | 3.303±0.073 |
75 | 5.061±0.050 | 4.870±0.062 | 4.551±0.044 | 3.448±0.054 |
100 | 5.164±0.061 | 4.952±0.031 | 4.652±0.051 | 3.531±0.041 |
3.2. Constitutive Modeling and Model Fitting
We analyzed data from colonic (n = 10), intermediate (n = 11), and rectal (n = 11) specimens of colorectum each separated into inner and outer composite layers. Thus, we fitted the constitutive model ((1)–(4)) to stress-stretch data from 64 individual biaxial extension tests. Figure 2 presents the results of our model fittings against the layer-separated experimental data. In the legend of Fig. 2 (and Figs. 3, 4) EXP, FEA, C, and A are abbreviations for experiment, finite element analyses, and the circumferential and axial (longitudinal) directions, respectively.
Figure 2:
(a) Schematic diagram of the biaxial extension tests performed on three locations of layer-separated inner and outer composite colorectum. (b)–(g) Experimental data (red and blue circles) with corresponding model predictions (solid and dashed curves) for colonic ((b),(e)), intermediate ((c),(f)), and rectal ((d),(g)) colorectum undergoing biaxial extension for inner ((b)–(d)) and outer ((e)–(g)) composite layers. EXP = EXPeriment, FEA = Finite Element Analyses, C = Circumferential, and A = Axial.
Figure 3:
(a) Schematic diagram of the biaxial extension tests performed on three locations of bulk composite colorectum. (b)–(d) Mean experimental data (red and blue squares, plus error bars for standard deviation) with corresponding model predictions (solid and dashed curves) for colonic (b), intermediate (c), and rectal (d) bulk composite specimens of colorectum undergoing biaxial extensions. EXP = EXPeriment, AVE = Mean, FEA = Finite Element Analyses, C = Circumferential, and A = Axial.
Figure 4:
(a) Schematic diagram of the pressure-diameter test tests performed on four individual segments of bulk composite colorectum. (b) Experimental data (multi-colored squares) with corresponding model predictions (solid curves) for four bulk composite segments of colorectum undergoing pressure-diameter tests. EXP = EXPeriment and FEA = Finite Element Analyses.
Table 4 summarizes the resulting averaged model parameters for each test population (colonic, intermediate, or rectal; inner or outer) as Mean±Standard Deviation (M±SD). In Appendix B, Table B.5 and Table B.6, we present the results of our model fitting for each specimen (inner and outer composite, respectively) for each longitudinal location (colonic, intermediate, and rectal).
Table 4:
Model parameters (M ± SD) for the anisotropic, separated layers of inner and outer composites of colorectum.
Segment | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
---|---|---|---|---|---|
Inner Colonic (n = 10) | 31.58±11.38 | 230.6±92.51 | 95.07±89.47 | 55.98±9.915 | 0.9380±0.0204 |
Inner Intermediate (n = 11) | 15.95±6.390 | 119.2±57.82 | 35.49±15.63 | 51.14±5.187 | 0.9496±0.0246 |
Inner Rectal (n = 11) | 14.53±6.350 | 95.21±39.42 | 31.73±12.73 | 62.07±14.64 | 0.9430±0.0253 |
Outer Colonic (n = 10) | 83.10±21.80 | 573.9±142.4 | 69.75±39.61 | 47.58±1.128 | 0.9436±0.0233 |
Outer Intermediate (n = 11) | 39.19±19.98 | 223.1±63.17 | 37.22±23.56 | 49.51±7.137 | 0.9488±0.0301 |
Outer Rectal (n = 11) | 8.238±3.500 | 44.32±13.93 | 35.80±27.96 | 52.98±10.16 | 0.9419±0.0271 |
3.3. Validating the Model
3.3.1. Biaxial Extension Testing of Bulk Composite
Figure 3 presents the simulated biaxial extension tests (FE model of the reconstructed bulk composite specimen using the mean model parameters, cf. Table 4) against the mean experimental results (noted as EXP AVE) for the bulk composite colorectum quantified independently (Siri et al., 2019a).
3.3.2. Pressure-Diameter Testing of Bulk Composite
Figure 4 presents the simulated outer diameter-pressure responses (FE model of the reconstructed bulk composite segments using the mean model parameters, cf. Table 4) against corresponding, independent experimental results from four individual tests of intact colorectums.
4. Discussion
4.1. Experimental Evidence on the Colorectum
We observed that when separating the bulk composite tissues into inner and outer composites the latter two changed their circumferential lengths. To support our modeling, we quantified these residual stretches; in the circumferential direction these are compressive in the inner composite and tensile in the outer composite.
To aid in validating our constitutive models and modeling framework we performed new pressure-diameter tests on bulk (intact) tubular segments of colorectum. Each of the four specimens tested had different diameters under internal pressures of 10 mmHg, but followed similar nonlinear pressure-diameter responses under increasing internal pressures.
4.2. Constitutive Modeling and Model Fitting
We present the first theoretical framework to simulate the biomechanics of distal colorectum, including both longitudinal and through-thickness heterogeneity, based on constitutive modeling of biaxial extension tests of colon tissues from mice. We fitted our constitutive model to our recent data generated from biaxial extension tests on layer-separated (inner mucosalsubmucosal composite and outer muscular-serosal composite) specimens from three longitudinal locations (colonic, intermediate, and distal), cf. (Siri et al., 2019a,b). To support our modeling, we measured the change in circumferential lengths when separating bulk composite specimens (reference configurations) into inner and outer composites (current configurations). Incorporating these mechanical data, and data on both the thickness of the layers and the principal orientations of the collagen fibers acquired via imaging with SHG, we modeled the wall of the colorectum as a two-layered, residually stressed structure via FE analyses and independently verified the predictive power of our framework in biaxial extension and pressure-diameter tests.
We used the angle α, defined as the principal orientation of fiber reinforcement with respect to the circumferential direction and implemented to compute the diffusion tensor, as a fitting parameter. In future applications of the constitutive model these diffusion tensors could be directly measured and implemented into FE models. For both the inner and outer composite, our results present stiffer mechanical properties in the longitudinal versus circumferential directions which implies fiber alignments preferentially in the longitudinal versus circumferential directions (Siri et al., 2019b). Our fitting results for α indicate varying anisotropy from the proximal colonic to the distal rectal locations where the rectal segment shows the greatest longitudinal stiffness, with α = ±62.07 ± 14.64° for the inner rectal and α = ±52.98 ± 10.16° for the outer rectal segments. The fitted values of α agree well with our independent results determined by nonlinear imaging via SHG where we estimate that α ~ ±60°) (Siri et al., 2019a).
We employed a constitutive model based on an ODF to maintain generality for possible assimilation of imaging data in the future. We specified the ODF via a symmetric, positive-definite diffusion tensor which determines the local 3-D orientation distribution of the fiber network (Basser et al., 1994; Pierce et al., 2016). The constitutive model, and fitted model parameters, reliably reproduce the results from mechanical tests with the correlation coefficients R2 ~ 0.94 – 0.95, cf. Table 4.
Constitutive models for colon tissues are relatively rare, but include Bellini et al. (2011); Sokolis and Sassani (2013); Carniel et al., 2015); Puértolas et al. (2020). In particular, Puértolas et al. (2020) provides a nice comparison of five different fiber-reinforced, large strain constitutive models by investigating their ability to fit experimental data from biaxial extension tests on specimens of bulk colon from pigs. Our constitutive model and modeling framework advances the field by addressing through-thickness mechanical heterogeneity (of different tissue layers), incorporating the orientation of collagen fibers determined via imaging experiments, and incorporating residual stretches/stresses quantified by separating the tissue layers. We based our calibration on data from layer-separated biaxial extension tests, and validated our model using independent data from bulk composite biaxial extension tests and pressure-diameters tests. These two experiments provide loading conditions that mimic those in vivo, cf. Shahzad et al. (2015), Puértolas et al. (2020), as opposed to computational models calibrated using data from uniaxial extension tests (Carniel et al.).
4.3. Validating the Model
We validated our constitutive models and modeling framework with two FE simulations and successfully predicted independent experimental data from both biaxial extension tests of intact colorectal specimens and pressure-diameter tests from segments of tubular colorectums. These validations also indicate that the potentially damaging effects of mechanically separating the layers are negligible, i.e., we can separate, test mechanically, and model the separated layers, and use these data to create a layered mechanical model that’s able to reproduce the bulk response in two loading modes.
4.3.1. Biaxial Extension Testing of Bulk Composite
We reconstructed the bulk colorectum specimens from colonic, intermediate, and rectal locations numerically, including the deformations that capture the intra-tissue residual stresses. Our predictions of the biaxial extension tests for the three longitudinal locations agree well with the averaged experimental data collected from an independent cohort of bulk (intact) specimens, see Fig. 3. Our results again indicate strong mechanical heterogeneity with decreased longitudinal and circumferential stiffness from the colonic to the rectal locations.
4.3.2. Pressure-Diameter Testing of Bulk Composite
There was no statistically significant difference in the FE-predicted pressure-diameter responses from segments of tubular colorectums from different longitudinal locations (colonic, intermediate, and rectal) despite the clear longitudinal heterogeneity in the biomechanical properties (model parameters) of the mouse colons. The nearly constant pressure-diameter responses primarily result from the changing wall thicknesses (inner and outer composite layers) along the longitudinal direction. Applying the experimentally determined wall thicknesses and our fitted constitutive models (both for the inner and outer composite layers), our predictions of pressure-diameter tests representing different longitudinal segments agree well with the experimental data collected from four independent tests, see Fig. 4.
4.4. Limitations and Outlook
We acknowledge several limitations of our study. We assumed homogeneous mechanical properties for the inner and outer composite layers which are themselves heterogeneous through the thickness. Perhaps additional imaging data, e.g., SHG data, could better inform future attempts at modeling the serosal, muscular, mucosal, and submucosal layers separately. Refinements in the mechanical testings may also facilitate better understanding of the layer-specific contributions to the bulk (intact) mechanical behavior of the colon tissues.
We hope to improve FE analyses of colorectum by establishing constitutive models describing the longitudinal and through-thickness heterogeneity present in the colons of mice. Our constitutive models and modeling framework facilitate analyses of both fundamental questions (e.g., structure-function relationships, growth and remodeling in health and disease) and specific applications (e.g., device design, minimally invasive surgery, and biomedical research). Additionally, our simulations capture biomechanical heterogenity across both the longitudinal and through-thickness directions of the colorectum, highlighting the differential roles of sensory nerve endings in different regions of the colorectum in visceral mechanotransduction.
Acknowledgment
This material is based upon work supported by NSF 1727185 and NIH 1R01DK120824-01.
Appendix A. Orientation Distribution Function
To facilitate implementing the ODF numerically, we write this as
(A.1) |
with
(A.2) |
(A.3) |
and
(A.4) |
and with
(A.5) |
Appendix B. Model Parameters for Each Specimen of Colorectum
Table B.5 presents the results of our model fitting for each specimen of inner composite for each longitudinal location (colonic, intermediate, and rectal).
Table B.6 presents the results of our model fitting for each specimen of outer composite for each longitudinal location (colonic, intermediate, and rectal).
Table B.5:
Model parameters for the anisotropic, separated layers of inner composites of colorectum.
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
---|---|---|---|---|---|
1 | 25.989 | 111.76 | 53.249 | 48.316 | 0.9702 |
2 | 11.331 | 97.616 | 15.416 | 47.061 | 0.9190 |
3 | 15.709 | 154.52 | 29.304 | 47.718 | 0.9302 |
4 | 28.168 | 261.96 | 13.837 | 52.991 | 0.9558 |
5 | 41.954 | 260.56 | 131.78 | 77.680 | 0.9532 |
6 | 44.744 | 340.60 | 166.43 | 61.347 | 0.9217 |
7 | 38.023 | 361.32 | 296.62 | 65.725 | 0.9090 |
8 | 32.524 | 230.01 | 59.678 | 49.195 | 0.9215 |
9 | 42.958 | 307.15 | 140.64 | 58.50 | 0.9433 |
10 | 34.435 | 180.58 | 43.745 | 51.270 | 0.9564 |
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
1 | 7.5715 | 90.692 | 18.973 | 46.418 | 0.9378 |
2 | 8.3813 | 68.355 | 21.613 | 47.574 | 0.9811 |
3 | 18.217 | 108.61 | 41.604 | 55.696 | 0.9775 |
4 | 15.071 | 61.500 | 29.802 | 48.568 | 0.9208 |
5 | 12.311 | 104.97 | 20.851 | 48.494 | 0.9177 |
6 | 27.772 | 265.06 | 47.548 | 62.398 | 0.9885 |
7 | 17.921 | 108.26 | 38.606 | 48.275 | 0.9514 |
8 | 23.037 | 155.10 | 69.685 | 55.536 | 0.9479 |
9 | 12.246 | 97.559 | 29.703 | 47.265 | 0.9586 |
10 | 11.261 | 85.841 | 23.078 | 47.284 | 0.9398 |
11 | 21.617 | 165.28 | 48.921 | 55.079 | 0.9247 |
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
1 | 18.198 | 108.10 | 35.164 | 51.181 | 0.9482 |
2 | 6.9493 | 45.683 | 16.866 | 48.821 | 0.9067 |
3 | 18.324 | 103.79 | 26.599 | 90.000 | 0.9740 |
4 | 14.724 | 81.366 | 40.665 | 74.722 | 0.9337 |
5 | 15.360 | 70.419 | 52.243 | 57.824 | 0.9085 |
6 | 7.7974 | 70.478 | 19.205 | 48.056 | 0.9634 |
7 | 7.7971 | 70.478 | 19.205 | 48.056 | 0.9597 |
8 | 5.9340 | 55.783 | 18.932 | 48.247 | 0.9609 |
9 | 21.109 | 168.34 | 50.868 | 70.018 | 0.9106 |
10 | 23.077 | 152.45 | 35.147 | 75.046 | 0.9700 |
11 | 20.547 | 120.41 | 34.144 | 70.742 | 0.9377 |
Table B.6:
Model parameters for the anisotropic, separated layers of outer composites of colorectum.
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
---|---|---|---|---|---|
1 | 68.050 | 671.02 | 32.692 | 46.080 | 0.9722 |
2 | 66.690 | 411.82 | 39.625 | 46.404 | 0.9189 |
3 | 99.972 | 796.65 | 90.412 | 49.335 | 0.9734 |
4 | 99.997 | 520.53 | 120.47 | 49.123 | 0.9451 |
5 | 39.990 | 431.42 | 40.361 | 46.133 | 0.9119 |
6 | 99.999 | 598.98 | 114.79 | 47.383 | 0.9300 |
7 | 100.00 | 608.03 | 36.699 | 47.931 | 0.9499 |
8 | 55.697 | 388.14 | 19.574 | 46.443 | 0.9397 |
9 | 100.00 | 599.76 | 51.599 | 47.768 | 0.9709 |
10 | 85.928 | 797.88 | 99.372 | 47.728 | 0.9532 |
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
1 | 16.674 | 221.10 | 14.166 | 45.752 | 0.9022 |
2 | 72.762 | 303.81 | 79.525 | 69.970 | 0.9047 |
3 | 28.525 | 218.03 | 33.527 | 46.760 | 0.9221 |
4 | 47.182 | 235.99 | 47.001 | 48.053 | 0.9650 |
5 | 31.935 | 160.46 | 24.076 | 47.071 | 0.9388 |
6 | 22.044 | 206.74 | 31.889 | 46.220 | 0.9796 |
7 | 14.867 | 228.22 | 11.419 | 46.344 | 0.9843 |
8 | 67.471 | 338.74 | 61.017 | 53.744 | 0.9471 |
9 | 53.453 | 240.29 | 68.645 | 47.961 | 0.9685 |
10 | 27.206 | 198.38 | 14.415 | 46.130 | 0.9410 |
11 | 48.962 | 101.89 | 23.745 | 46.621 | 0.9836 |
Specimen | μ (kPa) | k1 (kPa) | k2 (–) | α (–) | R2 (–) |
1 | 6.0485 | 41.428 | 14.533 | 46.421 | 0.9527 |
2 | 13.657 | 49.140 | 69.611 | 71.718 | 0.9303 |
3 | 8.5285 | 43.579 | 33.001 | 48.534 | 0.9410 |
4 | 4.6230 | 37.327 | 12.880 | 46.541 | 0.9478 |
5 | 5.6189 | 42.241 | 18.854 | 48.866 | 0.9656 |
6 | 11.466 | 63.740 | 80.668 | 59.703 | 0.9817 |
7 | 12.675 | 64.252 | 83.655 | 72.415 | 0.9309 |
8 | 3.1291 | 42.413 | 13.820 | 46.611 | 0.9034 |
9 | 7.7750 | 54.232 | 26.766 | 47.997 | 0.9809 |
10 | 6.1281 | 34.627 | 15.792 | 46.335 | 0.9223 |
11 | 10.963 | 14.578 | 24.217 | 47.649 | 0.9044 |
Footnotes
Conflicts of Interest
We have no conflicts of interest to report.
References
- Basser PJ, Mattiello J, LeBihan D, 1994. Mr diffusion tensor spectroscopy and imaging. Biophys. J 66, 259–267. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bellini C, Glass P, Sitti M, Di Martino ES, 2011. Biaxial mechanical modeling of the small intestine. J. Mech. Beh. Biomed. Mat 4, 1727–1740. [DOI] [PubMed] [Google Scholar]
- Camilleri M, Halawi H, Oduyebo I, 2017. Biomarkers as a diagnostic tool for irritable bowel syndrome: where are we? Expert Rev. Gastroenterol. Hepatol 11, 303–316. [DOI] [PubMed] [Google Scholar]
- Carniel E, Gramigna V, Fontanella C, Frigo A, Stefanini C, Rubini A, Natali A, . Characterization of the anisotropic mechanical behaviour of colonic tissues: experimental activity and constitutive formulation. Exp. Physiol 99, 759–771. [DOI] [PubMed] [Google Scholar]
- Carniel EL, Mencattelli M, Bonsignori G, Fontanella CG, Frigo A, Rubini A, Stefanini C, Natali AN, 2015. Analysis of the structural behaviour of colonic segments by inflation tests: experimental activity and physio-mechanical model. Proc. Inst. Mech. Eng. H 229, 794–803. [DOI] [PubMed] [Google Scholar]
- Cervero F, Laird JM, 1999. Visceral pain. Lancet 353, 2145–2148. [DOI] [PubMed] [Google Scholar]
- Ciarletta P, Dario P, Tendick F, Micera S, 2009. Hyperelastic model of anisotropic fiber reinforcements within intestinal walls for applications in medical robotics. Int. J. Rob. Res 28, 1279–1288. [Google Scholar]
- Clarke G, Quigley EM, Cryan JF, Dinan TG, 2009. Irritable bowel syndrome: towards biomarker identification. Trends Mol. Med 15, 478–489. [DOI] [PubMed] [Google Scholar]
- Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA, 2002. Mechanical properties of the human gastrointestinal tract. J. Biomech 35, 1417–1425. [DOI] [PubMed] [Google Scholar]
- Feng B, Brumovsky PR, Gebhart GF, 2010. Differential roles of stretch-sensitive pelvic nerve afferents innervating mouse distal colon and rectum. Am. J. Physiol. Gastrointest. Liver Physiol 298, G402–G409. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng B, Gebhart G, 2015. In vitro functional characterization of mouse colorectal afferent endings. J. Vis. Exp, e52310. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng B, Gebhart GF, 2010. Characterization of silent afferents in the pelvic and splanchnic innervations of the mouse colorectum. Am. J. Physiol. Gastrointest. Liver Physiol 300, G170–G180. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng B, Kiyatkin ME, La JH, Ge P, Solinga R, Silos-Santiago I, Gebhart GF, 2013. Activation of guanylate cyclase-c attenuates stretch responses and sensitization of mouse colorectal afferents. J. Neurosci 33, 9831–9839. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng B, La JH, Schwartz ES, Gebhart GF, 2012. Irritable bowel syndrome: methods, mechanisms, and pathophysiology. neural and neuroimmune mechanisms of visceral hypersensitivity in irritable bowel syndrome. Am. J. Physiol. Gastrointest. Liver Physiol 302, G1085–G1098. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Feng B, Zhu Y, La JH, Wills ZP, Gebhart GF, 2015. Experimental and computational evidence for an essential role of nav1. 6 in spike initiation at stretch-sensitive colorectal afferent endings. J. Neurophysiol 113, 2618–2634. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ferruzzi J, Vorp DA, Humphrey JD, 2011. On constitutive descriptors of the biaxial mechanical behaviour of human abdominal aorta and aneurysms. J. R. Soc. Interface 8, 435–450. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gasser TC, Ogden RW, Holzapfel GA, 2006. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations. J. R. Soc. Interface 3, 15–35. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gong X, Xu X, Lin S, Cheng Y, Tong J, Li Y, 2017. Alterations in biomechanical properties and microstructure of colon wall in early-stage experimental colitis. Exp. Ther. Med 14, 995–1000. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Higa M, Luo Y, Okuyama T, Shiraishi Y, Liu H, Yambe T, Takagi T, 2007. In vivo measurements and constitutive modeling of colon tissue, in: World Congress on Medical Physics and Biomedical Engineering 2006, Springer. pp. 3186–3189. [Google Scholar]
- Holzapfel GA, Unterberger MJ, Ogden RW, 2014. An affine continuum mechanical model for cross-linked f-actin networks with compliant linker proteins. J. Mech. Beh. Biomed. Mat 38, 78–90. [DOI] [PubMed] [Google Scholar]
- Howes M, Hardy W, 2012. Material properties of the post-mortem colon in high-rate equibiaxial elongation. Biomed. Sci. Instrum 48, 171–178. [PubMed] [Google Scholar]
- Jiminez JA, Uwiera TC, Inglis GD, Uwiera RR, 2015. Animal models to study acute and chronic intestinal inflammation in mammals. Gut Pathog. 7, 29. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kiyatkin ME, Feng B, Schwartz ES, Gebhart GF, 2013. Combined genetic and pharmacological inhibition of trpv1 and p2×3 attenuates colorectal hypersensitivity and afferent sensitization. Am. J. Physiol. Gastrointest. Liver Physiol 305, G638–G648. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Maas SA, Ellis BJ, Ateshian GA, Weiss JA, 2012. Febio: finite elements for biomechanics. J. Biomech. Eng 134. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Massalou D, Masson C, Foti P, Afquir S, Baqué P, Berdah SV, Bége T, 2016. Dynamic biomechanical characterization of colon tissue according to anatomical factors. J. Biomech 49, 3861–3867. [DOI] [PubMed] [Google Scholar]
- Pasricha PJ, Willis WD, Gebhart GF, 2006. Chronic abdominal and visceral pain: Theory and practice. Taylor & Francis; US. [Google Scholar]
- Patel B, Chen H, Ahuja A, Krieger JF, Noblet J, Chambers S, Kassab GS, 2018. Constitutive modeling of the passive inflation-extension behavior of the swine colon. J. Mech. Beh. Biomed. Mat 77, 176–186. [DOI] [PubMed] [Google Scholar]
- Pierce DM, Unterberger MJ, Trobin W, Ricken T, Holzapfel GA, 2016. A microstructurally based continuum model of cartilage viscoelasticity and permeability incorporating measured statistical fiber orientations. Biomech. Model. Mechanobiol 15, 229–244. [DOI] [PubMed] [Google Scholar]
- Puértolas S, Peña E, Herrera A, Ibarz E, Gracia L, 2020. A comparative study of hyperelastic constitutive models for colonic tissue fitted to multiaxial experimental testing. J. Mech. Beh. Biomed. Mat 102, 103507. [DOI] [PubMed] [Google Scholar]
- Qiao Y, Pan E, Chakravarthula S, Han F, Liang J, Gudlavalleti S, 2005. Measurement of mechanical properties of rectal wall. J. Mater. Sci.Mater. Med 16, 183–188. [DOI] [PubMed] [Google Scholar]
- Shahzad M, Kamran A, Siddiqui MZ, Farhan M, 2015. Mechanical characterization and fe modelling of a hyperelastic material. Mater. Res 18, 918–924. [Google Scholar]
- Siri S, Maier F, Chen L, Santos S, Pierce DM, Feng B, 2019a. Differential biomechanical properties of mouse distal colon and rectum innervated by the splanchnic and pelvic afferents. Am. J. Physiol. Gastrointest. Liver Physiol 316, G473–G481. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Siri S, Maier F, Santos S, Pierce DM, Feng B, 2019b. Load-bearing function of the colorectal submucosa and its relevance to visceral nociception elicited by mechanical stretch. Am. J. Physiol. Gastrointest. Liver Physiol 317, G349–G358. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sokolis DP, Sassani SG, 2013. Microstructure-based constitutive modeling for the large intestine validated by histological observations. J. Mech. Beh. Biomed. Mat 21, 149–166. [DOI] [PubMed] [Google Scholar]
- Watters D, Smith A, Eastwood M, Anderson K, Elton R, 1985a. Mechanical properties of the rat colon: the effect of age, sex and different conditions of storage. Q. J. Exp. Physiol 70, 151–162. [DOI] [PubMed] [Google Scholar]
- Watters D, Smith A, Eastwood M, Anderson K, Elton R, Mugerwa J, 1985b. Mechanical properties of the colon: comparison of the features of the african and european colon in vitro. Gut 26, 384–392. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhao J, Liao D, Gregersen H, 2019. Mechanical analysis of intestinal contractility in a neonatal maternal deprivation irritable bowel syndrome rat model. J. Biomech 93, 42–51. [DOI] [PubMed] [Google Scholar]