Medium Term Radiographic and Clinical Outcomes Using a Modular Tapered Hip Revision Implant

Gihan Jayasinghe 1,, Chris Buckle 1, Lucy Clare Maling 1, Christopher To 1, Chukwudubem Anibueze 1, Parthiban Vinayakam 1, Richard Slack 1
PMCID: PMC8056170  PMID: 33898674

Abstract

Background

The rate of revision hip arthroplasty surgery is rising. Surgeons must use implants with proven outcomes to help overcome the technical challenges faced during revision surgery. However, outcome studies using these implants are limited. The aim of this study is to investigate the radiographic and clinical outcomes of the Stryker Restoration stem, the most commonly used hip revision stem in the United Kingdom (UK).

Methods

A retrospective review of a single surgeon case series was performed. Immediate postoperative radiographs were analyzed for offset and leg length discrepancy. Radiographic evidence of subsidence was assessed using follow-up radiographs. Kaplan-Meier survival analysis was applied using explantation and reoperation as endpoints. Patient-reported outcomes were measured using the Oxford Hip Score and EQ-5D-5L.

Results

One hundred ninety-eight cases were identified. Mean follow-up duration was 51.8 months (range: 24-121). Stem survival during this period was 98%. Reoperation for any reason was 13%. Mean subsidence was 4.18 mm. Analysis of variance testing showed no difference in mean subsidence between revision indications. Mean offset and leg length discrepancies were measured at 4.5 mm and 4.3 mm, respectively. The mean Oxford Hip Score for participants was 27.6.

Conclusions

This series demonstrates excellent implant survival, with radiographic parameters for reconstruction and subsidence levels comparable to those in the existing literature. The tapered modular hip revision stem provides surgeons with the intraoperative flexibility to overcome some of the anatomical difficulties encountered during revision surgery; this is reflected in the radiographic and clinical outcomes of the cohort in this study.

Keywords: Revision hip arthroplasty, Outcomes, Survival, PROMS, Tapered modular stems

Introduction

The British National Joint Registry projects a 134% rise in patients requiring hip surgery by 2030, associated with a projected rise of 31% for revision hip surgery [1]. It is imperative that surgeons are prepared for this predicted endemic of hip revision surgery with appropriate, outcome-proven implants. Several options for femoral revision prostheses are available, including monobloc and modular implants. Monobloc prostheses offer several potential advantages, including simplified equipment inventory and the associated costs, simplicity of use and avoidance of the potential problem of corrosion at the modular junction, which may lead to implant failure and osteolysis. However, restoration of normal hip anatomy and biomechanics is harder to achieve without modularity as the metaphyseal-diaphyseal mismatch cannot easily be addressed [2]. Paprosky and Weeden demonstrated high failure rates using fully coated monobloc prostheses, particularly in patients exhibiting type III and IV femoral defects [3].

Modular revision stems allow metaphyseal and diaphyseal components to be individually sized according to the femoral morphology. Modular tapered stems allow metaphyseal bone defects to be bypassed by means of a distal fix, with load transfer occurring in the isthmus of the femur. Stem bodies are available in varying diameters. Some have inbuilt splines enabling axial and rotational stability when directly resting against viable bone. Offset can also be increased according to required soft tissue tension, to optimize stability [4]. An example of such a stem is the Stryker Restoration stem (Kalamazoo, MI). This is the most used revision prosthesis in the UK [5]. Several studies have reported outcomes using such stems [[6], [7], [8], [9], [10], [11]]. However, numbers of cases in these series have been limited (the largest reported cases series n = 125).

The aim of this study is to report the medium-term radiological and clinical outcomes of the Stryker Restoration stem (Kalamazoo, MI). We aim to compare local experience with existing data series and contribute to the body of evidence regarding these stems.

Material and methods

This is a single-surgeon, retrospective, consecutive case series at a single district general hospital. Ethical approval was applied for and granted by the hospital ethics committee.

A local orthopedic database was used to identify patients undergoing revision hip surgery between 2009 and 2016. The minimum follow-up period was 2 years. The database was cross-referenced with the hospital picture and communication system to identify patients undergoing revision surgery using the Stryker Restoration stem (Kalamazoo, MI).

Preoperative and postoperative clinic letters were reviewed to ascertain indications for revision, postoperative clinical outcomes, and adverse events including re-revision and complications that did not require the patient to return to theatre. Patients were routinely followed up at 6 weeks, 6 months, and yearly until discharge, unless there were concerns necessitating more frequent clinical follow-up. Demographic data were collected on patient age, gender, indication for surgery, and American Society of Anesthesiologists physical status classification grade.

Radiographic analysis was performed by 2 independent assessors who were blinded to the clinical outcomes and independent of the patient’s operations. Preoperative radiographs were classified using the Paprosky classification [12] or the Vancouver classification [13] for patients being treated for periprosthetic fractures. Postoperative radiographs were examined for leg length discrepancy (LLD), offset, and evidence of extended trochanteric osteotomy (ETO). Radiographic measurements were made using calibrated digital radiographs. Leg length was measured as the vertical distance from the top of the lesser trochanter to the bottom of the teardrop and compared with the contralateral side. If the lesser trochanter was not visible, then a measurement was taken from a line perpendicular to the base of the ischial tuberosities to the center of the femoral head. Femoral offset was measured as the perpendicular distance from the center of the femoral head to the anatomical axis of the femur [14]. If the contralateral hip was prosthetic, comparisons were made to the preoperative radiographs. The most recent follow-up radiograph taken greater than 2 years postoperatively was reviewed for evidence of ETO union, periprosthetic fracture union, and subsidence. ETO and fracture healing were classified as union or nonunion. Stem position was measured from a fixed point on the prosthesis (superior neck/shaft) and a fixed point on the femur (tip of the greater trochanter, cerclage wire, or top the lesser trochanter) [8,15]. Subsidence was calculated as the difference in this measurement on immediate postoperative and follow-up radiographs.

Patient-reported outcomes were assessed using the EQ-5D-5L and Oxford Hip Score (OHS) questionnaires. Permission to use the EQ-5D-5L questionnaire was granted by the EuroQol Research foundation [16]. The questionnaires were performed by 2 independent assessors via telephone; verbal consent was obtained at this time.

All surgeries were performed by a single surgeon. The extensile posterior approach and same operative technique for stem implantation was used throughout. The postoperative protocol was the same for all patients. All patients were permitted to fully weight bear as tolerated on day one. Hip precautions were used in the early postoperative period. Pelvic and femoral radiographs were performed on postoperative day one. The postoperative thromboprophylaxis protocol involved low-molecular-weight heparin and pneumatic calf pumps while in hospital, followed by a 28-day course of aspirin and antithrombotic stockings. Postoperative analgesia was individualized to patient requirements.

Statistical analysis was carried out using the statistical package for the social sciences (SPSS, IBM, Armonk, NY). Analysis was undertaken using each stem implanted as an individual case. Means and ranges were reported for continuous data and percentages for nominal data. Subsidence was analyzed using analysis of variance (ANOVA) testing to observe the differences depending on the revision indication. Survival analysis was conducted by plotting Kaplan-Meier curves with revision of the stem and reoperation for any reason as endpoints.

Results

During the study period, 198 implanted restoration stems (Kalamazoo, MI) were identified in 182 patients. The mean age was 76 years (46-95), and 64% were female. Mean follow-up period was 51.8 months (range: 24-121). Sixty-four percent (n = 125) of cases underwent cup and stem revision, and 36% (n = 73) underwent stem revision alone. Indications for the revision were aseptic loosening (43%), periprosthetic fracture (26%), hemiarthroplasty revision (14%), infection (10%), dislocation (3%), and other (4%). Distribution of cases across each of the Paprosky femoral classification [6] was as follows: 24% type II, 58% type IIIa, 16% type IIIb, and 2% type IV. Patients undergoing revision for periprosthetic fracture were classified using the Vancouver classification [7]: Vancouver A (n = 3), Vancouver B2 (n = 47), and Vancouver B3 (n = 2). Demographics are shown in Table 1.

Table 1.

Demographics of patients undergoing surgery.

Age 76 (46-95)
Sex
 Male 64 (34%)
 Female 118 (66%)
Side
 Right 99 (54%)
 Left 69 (38%)
Bilateral 15 (8%)
American Society of Anesthesiologists
 I 7 (4%)
 II 99 (54%)
 III 73 (40%)
 IV 3 (2%)
Revision
 Stem only 125 (64%)
 Stem + Acetabulum 73 (36%)
Indication
 Aseptic loosening 86 (43%)
 Periprosthetic fracture 52 (26%)
 Hemiarthroplasty revision 27 (14%)
 Infection 20 (10%)
 Dislocation 5 (3%)
 Other 8 (4%)

Mean offset difference was 4.5 mm (range: 0.7-16.9), and mean LLD was 4.3 mm (range: 0-11.5). One hundred and forty cases, with a minimum 2 years of postoperative radiological follow-up, were analyzed for evidence of stem subsidence. The mean subsidence was 4.2 mm (range: 0-33 mm). One hundred and five stems (75%) subsided <5 mm, 21 stems (15%) 5-10 mm, and 14 stems (10%) demonstrated subsidence >10 mm (range: 11-33 mm) (Table 2). Subsidence was analyzed according to indication for revision (Table 3). Revision for peri-prosthetic fracture demonstrated the highest level of subsidence (5.42 mm, standard deviation: 7.25). However, ANOVA testing showed no significant difference between each indication (P = 1.00).

Table 2.

Indication for all stems with subsidence >10 mm.

Subsidence (mm) Indication
10.23 IIIa
10.55 AVN
10.70 IIIa
11.09 IIIa
12.29 B2
13.29 Failed IM nail
13.33 B2
13.38 IIIa
14.28 Revised hemiarthroplasty
16.31 IIIA
16.63 Infection
20.91 IIIb
26.68 B2
33.36 B2

AVN, avascular necrosis; IM, intramedullary.

Table 3.

Mean subsidence for each recorded indication.

Indication Subsidence mean (SD), mm
Aseptic loosening 3.76 (4.15)
Periprosthetic fracture 5.42 (7.25)
Hemiarthroplasty revision 3.75 (3.95)
Infection 3.09 (4.17)
Other 5.35 (3.25)

ETO was performed in 62 cases. At follow-up, there was a 94% radiographic union rate of ETO. Patients treated for periprosthetic fracture with the modular tapered stem demonstrated radiographic union of 96% at the end of the follow-up period.

The survival rate of the stem was 98.5%, where stem explant was used as the end point. The indication for removal was deep infection in all (n = 4) cases. The survival curve for the stem is shown in Figure 1. Postoperative dislocation occurred in 15 cases (7.5%), with 5 cases requiring subsequent acetabular cup revision. In total, 26 cases required further surgery while retaining the stem, yielding an 89.6% survival using return to theatre as the end point (Fig. 2). The indications for return to theatre surgery are shown in Table 4. Postoperative complications that did not require reoperation were not identified in any case.

Figure 1.

Figure 1

Kaplan-Meier survival curve using removal of stem as an endpoint. Censored data indicated by crosses.

Figure 2.

Figure 2

Kaplan-Meier survival curve using return to theatre for any cause as an endpoint. Censored data indicated by crosses.

Table 4.

Reason for return to theatre.

Reason for return to theatre Cases Percentage
Manipulation for dislocation 10 5%
Cup revision for dislocation 5 2.5%
Explantation 4 2%
Intraoperative periprosthetic fracture 2 1%
Postoperative periprosthetic fracture 2 1%
Removal of trochanteric grip plate 2 1%
Removal of Dall-Miles cable 1 0.5%

Attempts were made to conduct telephone interviews to assess the PROMs for the 122 patients that survived to the end of the follow-up period. The Oxford Hip Score and EQ-5D-5L was successfully collected for 47 patients. The remaining patients were uncontactable or did not consent to take part in the study. The average OHS was 27.6. Figure 3 shows the EQ-5D-5L scores for each domain.

Figure 3.

Figure 3

EQ-5D-5L scores for each domain questioned.

Discussion

The survival rate of the stem was excellent at 98.5% and in accordance with other published studies investigating modular hip revision stems (Table 5). Four stems were removed during the follow-up period. The indication for stem removal was postoperative prosthetic joint infection in all. One of these patients had pre-existing prosthetic joint infection. The rate of return to theatre for any reason was 13%. Other published studies have reported similar rates of 2%-29%.

Table 5.

Summary of existing studies using modular revision hip implants.

Author Stem Number of patients Follow-up period Indication Survivorship PROMS Subsidence LLD Offset
Abdel et al., 2014 [17] Link MP 29 4.5 PP fracture 95 83 1 stem >5 mm N.I N.I
Restoration 15
Huddleston et al., 2015 [18] ZMR 132 9 Femoral bone defects 1-3A 91 N.I N.I N.I N.I
Restoration 13
REDAPT 5
Abdel et al., 2017 [19] Link MP 375 4.5 Aseptic loosening 96 75 12 had subsidence > 5 mm (mean 16 mm) N.I N.I
Restoration 144
Koster et al., 2008 [20] Profemur 73 6.2 Aseptic loosening 93.9 HHS 75 Not calculated (divided) N.I N.I
Park et al., 2007 [21] Lima revision stem 62 4.2 Aseptic loosening, infection, periprosthetic fracture 98.4% HHS 87.3 1.1 mm N.I N.I
Neumann et al., 2012 [22] Modular plus 55 5.6 Vancouver B2 and B3 fractures 96% HHS 72 2 cases >5 mm N.I N.I
Moreta et al., 2018 [23] S-ROM 51 5.7 Aseptic loosening, infection, instability 96% N.I 1 stems migrated
>4 mm
N,I N.I
Cameron, 2002 [24] S-ROM 211 6.5 Aseptic loosening 94% 96% N.I N.I N.I
Richards et al., 2010 [25] ZMR 109 3 Aseptic loosening, Infection, periprosthetic fracture N.I OHS 77 95% N.I N.I
Van Houwelingen et al., 2013 [26] ZMR 65 7 Aseptic loosening, fracture, instability 84% 10-year cumulative survival OHS 75 6 pts >5 mm
Average 12.3 mm
N.I N.I
Munro et al., 2014 [27] ZMR
Revitan
55 4.5 Vancouver B2 and B3 fractures 96 N.I nil N.I N.I
Wirtz et al., 2000 [28] Titan 142 2.5 Aseptic loosening, infection 96% HHS 89.3 >5 mm, 6 cases N.I N.I
Schuh et al., 2004 [29] Titan 79 4 Aseptic loosening 96.21% HHS 86.8 1 stem >2 mm N.I N.I
Hoberg et al., 2015 [30] Titan 136 4.5 Aseptic loosening, infection, periprosthetic fracture 93.2% HHS 75.1 N.I N.I N.I
Girard et al., 2011 [31] Revitan 183 5.9 Aseptic loosening 98.4% HHS 83.2 3 mm N.I N.I
Fink et al., 2012 [32] Revitan 22 5.6 Vancouver B2 and B3 fractures N.I 81.6 N.I N.I N.I
Fink et al., 2014 [33] Revitan 116 7.5 Femoral bone defects 91.7 HHS 88.2 N.I N.I N.I
McInnis et al., 2006 [34] Revitan 70 3.9 Aseptic loosening, infection, periprosthetic fracture 92% OHS 21.1 9.9 mm 11.7 N.I
Wang et al., 2013 Link MP 58 4.3 Femoral revision 97 81.4 1.6 mm 4.7 mm N.I
Hashem et al., 2017 [35] Link MP 132 4.5 Aseptic loosening, infection, periprosthetic fracture 99.2% N.I N.I N.I N.I
Kwong et al., 2003 [36] Link MP 143 3.3 Aseptic loosening, periprosthetic fractures, infection, instability 97.2 HHS 92 2.1 N.I N.I
Rodriguez et al., 2009 [37] Link MP 102 3.3 Aseptic loosening 95% N.I 7%, 2 mm N.I N.I
Weiss et al., 2011 [15] Link MP 63 4 Aseptic loosening, periprosthetic fracture, infection, instability 98% N.I 2.7 >5 mm 15% N.I
Amanatullah et al., 2015 [38] Link MP 92 6.4 Aseptic loosening, infections fractures 697 69
Houdek et al., 2015 [39] Link MP 57 5.9 Infections 87 HHS 76 4 mm N.I N.I
Stimac et al., 2014 [6] Restoration 125 4.3 Aseptic loosening, 96.8% HHS 85.7 0.64 mm 0.97 mm Total offset 151.3 mm
Palumbo et al., 2013 [7] Restoration 18 4.5 Aseptic loosening, infection, periprosthetic fracture 94% HHS 79 3.53 N.I N.I
Restrepo et al., 2011 [8] Restoration 118 4 Aseptic loosening, infection, periprosthetic fracture 99.2% HSS 77 <5 mm 98%
>5 mm 2%
95% 0-5 mm 16% restored
19% +3 −5 mm
16% −3 = −6
Dzaja et al., 2014 [9] Restoration 55 2.5 Aseptic loosening, infection, periprosthetic fracture 96% HSS 78 N.I N.I. N.I
Hernandez-Vaquero et al., 2015 [11] Restoration stem 12 3.7 Vancouver B2 and B3 fractures N.I 78 3.9 mm in 6 cases N.I N.I
Patel et al., 2010 [10] Restoration 43 2.4 Aseptic loosening, infection, osteolysis 95% N.I 2.5 mm N.I N.I
This study Restoration 198 4.3 Aseptic loosening, periprosthetic fracture, infection, instability 98.5% OHS 4.18 mm 4.34 mm 4.51 mm

PROMS, patient recorded outcome measures; HHS, Harris Hip Score; PP, periprosthetic.

Results for LLD in this study were ±4.3 mm, within the acceptable limits for primary hip replacement [40]. This finding is reassuring in the revision scenario where anatomical reconstruction can be challenging. Few previous studies [6,15,34,35] have reported radiological measures of postoperative offset and leg length. Difficulty in accurately measuring leg length [41] may explain the lack of prior reporting. These inaccuracies are related to the requirement of true anterior-posterior radiographs of the pelvis and femora to make this analysis accurately, and this is only achievable in some cases. Furthermore, inaccuracies in calibration of the radiographs make these measurements technically challenging. Stimac et al. achieved an LLD of 0.97 mm [6]. The methodology of this study reported the mean positive and negative leg length discrepancies, hence yielding a value close to zero. This means of descriptive analysis was not used in this study as a picture of overall LLD wanted to be obtained. If this alternative methodology had been used, the new value would be 0.9 mm. The mean offset change was calculated as ±4.5 mm, which is considered acceptable for primary hip arthroplasty [42]. To the authors knowledge, only one other study [6] has reported offset. This was measured using a different method of global offset, making the results incomparable.

Subsidence is a frequently reported complication of revision hip surgery. Modular tapered stems demonstrate higher rates of component osseointegration and lower rates of subsidence and re-revision when compared with modular cylindrical stems [43]. To avoid vertical downward migration, 4-5 cm of solid fixation in the isthmus is required [44]. Mean subsidence in this study was 4.18 mm, with 75% demonstrating <5 mm subsidence. Only 10% demonstrated subsidence >10 mm, with 6/10 of these stems used in cases with significant bone defects (IIIa/b) or peri-prosthetic fracture. Other studies reported findings between 0.64 mm and 16 mm. Some articles primarily investigate femurs with smaller femoral defects and lower Paprosky classifications [10,29] where one would expect stronger anchorage of the stem and little subsidence. Periprosthetic fractures accounted for 26% of revisions in this present study. These are known to have an increased rate subsidence [45]. A postulated reason for this is the increased femoral canal width and cortical discontinuity following a fracture. The average subsidence in this study following peri-prosthetic fractures was 5.42 mm, which was higher than that for any other indication. Despite this, ANOVA testing showed no difference in mean subsidence between the indication groups.

Stem modularity offers a number of potential advantages related to accurate sizing and fixation of revision femoral stems. However, modularity also has specific complications related to the modular junction including stem fracture and corrosion [[46], [47], [48]]. None of these complications were identified in this study. There were also no cases of stem fracture in this study, which can be compared to the study by Richards et al., who recorded 4 cases of implant fracture of the Zimmer ZMR stem (Warsaw, IN) in their study [25] and Houwelingen et al., who reported 5 fractured stems using the same implant [26].

Postoperative dislocation occurred in 15 cases (7.5%). Five were treated with cup revisions; 1 was a chronic dislocation in a very frail, multimorbid, bed-bound patient which made further revision surgery impossible. The remainder were treated with closed reduction and successful conservative management. The dislocation rate of 7.5% is in accordance with meta-analysis reporting an average dislocation rate after revision hip arthroplasty of 9.04% (range from 4%-30%) [49].

There is a paucity of evidence for the treatment of peri-prosthetic fractures with modular hip revision stems. The reported union rate for peri-prosthetic fractures ranges from 91% to 100% [22,45,50]. The union rate in this investigation was 96%, demonstrating the successful treatment of peri-prosthetic fractures with modular revision stems. The union rates after ETO is 94% in this study, which is comparable to those of other studies quoting over 90% [51].

Clinically, the Stryker Restoration stem (Kalamazoo, MI) proves to be successful, demonstrating an average OHS of 27.6. Only one other similar study by McMinnis et al. [25] used this score, with an average of 21.1. Richard et al. [34] normalized the OHS to 100, but because they failed to detail how they reached this conclusion, comparison was not possible. The EQ-5D-5L scores were again reassuring, with over 60% of patients reporting absent, mild, or moderate symptoms in all 5 domains.

The main weakness of this study is due to the single-center, single-surgeon experience that this case series originates from. This can result in numerous potential sources of bias within the study that may overestimate the efficacy of this implant. However, this type of evidence is common among the other literature identified across this subject area and offers information that is useful as part of a wider body of evidence in lieu of higher quality studies. Recording of patient-reported outcomes in this study was poor, with only 47 patients included. This may reflect the difficulties with retrospective data collection from elderly patient groups. It may guide further studies to use prospective data collection where possible, to reduce missing data.

Conclusions

This retrospective analysis of the Stryker Restoration modular tapered hip revision stem (Kalamazoo, MI) demonstrates its ability to successfully reconstruct proximal femora despite scenarios of substantial bone loss and peri-prosthetic fractures. This particular implant is currently the most used revision stem in the UK according to registry data [5]. To our knowledge, this is the largest study to investigate the outcomes and survivorship of the Stryker Restoration stem (Kalamazoo, MI). Radiographic outcomes are correlated with successful clinical outcomes and longevity of the implant.

Conflicts of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this article.

Appendix A. Supplementary data

Conflict of Interest Statement for Jayasinghe
mmc1.docx (9KB, docx)
Conflict of Interest Statement for Maling
mmc2.docx (9KB, docx)
Conflict of Interest Statement for Vinayakam
mmc3.docx (9KB, docx)
Conflict of Interest Statement for Slack
mmc4.docx (9KB, docx)
Conflict of Interest Statement for Anibueze
mmc5.docx (9KB, docx)
Conflict of Interest Statement for Buckle
mmc6.docx (9KB, docx)
Conflict of Interest Statement for To
mmc7.docx (9KB, docx)

LLD, leg length discrepancy; N.I., not investigated; OHS, Oxford Hip Score.

References

  • 1.Patel A., Pavlou G., Mújica-Mota R., Toms A. The epidemiology of revision total knee and hip arthroplasty in England and Wales: a comparative analysis with projections for the United States. A study using the National Joint Registry dataset. Bone Joint J. 2015;97(8):1076. doi: 10.1302/0301-620X.97B8.35170. [DOI] [PubMed] [Google Scholar]
  • 2.Sheth N.P., Nelson C.L., Springer B.D., Fehring T.K., Paprosky W.G. Acetabular bone loss in revision total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2013;21(3):128. doi: 10.5435/JAAOS-21-03-128. [DOI] [PubMed] [Google Scholar]
  • 3.Weeden S.H., Paprosky W.G. Minimal 11-year follow-up of extensively porouscoated stems in femoral revision total hip arthroplasty. J Arthroplasty. 2002;17(4 Suppl 1):134. doi: 10.1054/arth.2002.32461. [DOI] [PubMed] [Google Scholar]
  • 4.Stryker 2009. https://www.strykermeded.com/media/2009/restoration-modular-cone-conical-techniqueppdf.pdf [Accessed 1 June 2018]
  • 5.NJR 2017. http://www.njrcentre.org.uk/njrcentre/Reports,PublicationsandMinutes/Annualreports/tabid/86/Default.aspx [Accessed 1 June 2018]
  • 6.Stimac J.D., Boles J., Parkes N., Della Valle A.G., Boettner F., Westrich G.H. Revision total hip arthroplasty with modular femoral stems. J Arthroplasty. 2014;29(11):2167. doi: 10.1016/j.arth.2014.06.015. [DOI] [PubMed] [Google Scholar]
  • 7.Palumbo B.T., Morrison K.L., Baumgarten A.S., Stein M.I., Haidukewych G.J., Bernasek T.L. Results of revision total hip arthroplasty with modular, titanium-tapered femoral stems in severe proximal metaphyseal and diaphyseal bone loss. J Arthroplasty. 2013;28(4):690. doi: 10.1016/j.arth.2012.08.019. [DOI] [PubMed] [Google Scholar]
  • 8.Restrepo C., Mashadi M., Parvizi J., Austin M.S., Hozack W.J. Modular femoral stems for revision total hip arthroplasty. Clin Orthop Relat Res. 2011;469(2):476. doi: 10.1007/s11999-010-1561-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Dzaja I., Lyons M.C., McCalden R.W., Naudie D.D., Howard J.L. Revision hip arthroplasty using a modular revision hip system in cases of severe bone loss. J Arthroplasty. 2014;29(8):1594. doi: 10.1016/j.arth.2014.02.035. [DOI] [PubMed] [Google Scholar]
  • 10.Patel P.D., Klika A.K., Murray T.G., Elsharkawy K.A., Krebs V.E., Barsoum W.K. Influence of technique with distally fixed modular stems in revision total hip arthroplasty. J Arthroplasty. 2010;25(6):926. doi: 10.1016/j.arth.2009.07.006. [DOI] [PubMed] [Google Scholar]
  • 11.Hernandez-Vaquero D., Fernandez-Lombardia J., de los Rios J.L., Perez-Coto I., Iglesias-Fernandez S. Treatment of periprosthetic femoral fractures with modular stems. Int Orthop. 2015;39(10):1933. doi: 10.1007/s00264-015-2958-5. [DOI] [PubMed] [Google Scholar]
  • 12.Aribindi R., Barba M., Solomon M.I., Arp P., Paprosky W. Bypass fixation. Orthop Clin North Am. 1998;29:319. doi: 10.1016/s0030-5898(05)70330-8. [DOI] [PubMed] [Google Scholar]
  • 13.Duncan C.P., Masri B.A. Fractures of the femur after hip replacement. Instr Course Lect. 1995;44:293. [PubMed] [Google Scholar]
  • 14.Scheerlinck T. Primary hip arthroplasty templating on standard radiographs. A stepwise approach. Acta Orthop Belg. 2010;76(4):432. [PubMed] [Google Scholar]
  • 15.Weiss R.J., Beckman M.O., Enocson A., Schmalholz A., Stark A. Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty. J Arthroplasty. 2011;26(1):16. doi: 10.1016/j.arth.2009.11.009. [DOI] [PubMed] [Google Scholar]
  • 16.Harris K., Dawson J., Gibbons E. Systematic review of measurement properties of patient-reported outcome measures used in patients undergoing hip and knee arthroplasty. Patient Relat Outcome Measures. 2016;7:101. doi: 10.2147/PROM.S97774. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Abdel M.P., Lewallen D.G., Berry D.J. Periprosthetic femur fractures treated with modular fluted, tapered stems. Clin Orthop Relat Res. 2014;472(2):599. doi: 10.1007/s11999-013-2936-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Huddleston J.I., Tetreault M.W., Yu M. Is there a benefit to modularity in ‘simpler’femoral revisions? Clin Orthop Relat Res. 2016;474(2):415. doi: 10.1007/s11999-015-4474-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Abdel M.P., Cottino U., Larson D.R., Hanssen A.D., Lewallen D.G., Berry D.J. Modular fluted tapered stems in aseptic revision total hip arthroplasty. JBJS. 2017;99(10):873. doi: 10.2106/JBJS.16.00423. [DOI] [PubMed] [Google Scholar]
  • 20.Köster G., Walde T.A., Willert H.-G. Five-to 10-year results using a noncemented modular revision stem without bone grafting. J Arthroplasty. 2008;23(7):964. doi: 10.1016/j.arth.2007.08.024. [DOI] [PubMed] [Google Scholar]
  • 21.Park Y.-S., Moon Y.-W., Lim S.-J. Revision total hip arthroplasty using a fluted and tapered modular distal fixation stem with and without extended trochanteric osteotomy. J Arthroplasty. 2007;22(7):993. doi: 10.1016/j.arth.2007.03.017. [DOI] [PubMed] [Google Scholar]
  • 22.Neumann D., Thaler C., Dorn U. Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop. 2012;36(5):1045. doi: 10.1007/s00264-011-1371-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Moreta J., Uriarte I., Foruria X. Medium-term outcomes of the S-ROM modular femoral stem in revision hip replacement. Eur J Orthop Surg Traumatol. 2018:1. doi: 10.1007/s00590-018-2213-z. [DOI] [PubMed] [Google Scholar]
  • 24.Cameron H.U. The long-term success of modular proximal fixation stems in revision total hip arthroplasty. J Arthroplasty. 2002;17(4):138. doi: 10.1054/arth.2002.32462. [DOI] [PubMed] [Google Scholar]
  • 25.Richards C.J., Duncan C.P., Masri B.A., Garbuz D.S. Femoral revision hip arthroplasty: a comparison of two stem designs. Clin Orthop Relat Res. 2010;468(2):491. doi: 10.1007/s11999-009-1145-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Van Houwelingen A.P., Duncan C.P., Masri B.A., Greidanus N.V., Garbuz D.S. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10 years followup. Clin Orthop Relat Res. 2013;471(2):454. doi: 10.1007/s11999-012-2552-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Munro J.T., Masri B.A., Garbuz D.S., Duncan C.P. Tapered fluted modular titanium stems in the management of Vancouver B2 and B3 peri-prosthetic fractures. Bone Joint J. 2013;95(11_Supple_A):17. doi: 10.1302/0301-620X.95B11.32898. [DOI] [PubMed] [Google Scholar]
  • 28.Wirtz D.C., Heller K.-D., Holzwarth U., Siebert C. A modular femoral implant for uncemented stem revision in THR. Int Orthop. 2000;24(3):134. doi: 10.1007/s002640000135. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Schuh A., Werber S., Holzwarth U., Zeiler G. Cementless modular hip revision arthroplasty using the MRP Titan Revision Stem: outcome of 79 hips after an average of 4 years’ follow-up. Arch Orthop Trauma Surg. 2004;124(5):306. doi: 10.1007/s00402-004-0656-7. [DOI] [PubMed] [Google Scholar]
  • 30.Hoberg M., Konrads C., Engelien J. Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty. Int Orthop. 2015;39(9):1709. doi: 10.1007/s00264-015-2699-5. [DOI] [PubMed] [Google Scholar]
  • 31.Girard J., Roche O., Wavreille G., Canovas F., Le Béguec P. Stem subsidence after total hip revision: 183 cases at 5.9 years follow-up. Orthop Traumatol Surg Res. 2011;97(2):121. doi: 10.1016/j.otsr.2010.10.006. [DOI] [PubMed] [Google Scholar]
  • 32.Fink B., Grossmann A., Singer J. Hip revision arthroplasty in periprosthetic fractures of Vancouver type B2 and B3. J Orthop Trauma. 2012;26(4):206. doi: 10.1097/BOT.0b013e318220a94f. [DOI] [PubMed] [Google Scholar]
  • 33.Fink B., Urbansky K., Schuster P. Mid term results with the curved modular tapered, fluted titanium Revitan stem in revision hip replacement. Bone Joint J. 2014;96(7):889. doi: 10.1302/0301-620X.96B7.33280. [DOI] [PubMed] [Google Scholar]
  • 34.McInnis D.P., Horne G., Devane P.A. Femoral revision with a fluted, tapered, modular stem: seventy patients followed for a mean of 3.9 years. J Arthroplasty. 2006;21(3):372. doi: 10.1016/j.arth.2005.08.022. [DOI] [PubMed] [Google Scholar]
  • 35.Hashem A., Al-Azzawi A., Riyadh H., Mukka S., Sayed-Noor A. Cementless, modular, distally fixed stem in hip revision arthroplasty: a single-center study of 132 consecutive hips. Eur J Orthop Surg Traumatol. 2018;28(1):45. doi: 10.1007/s00590-017-2013-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Kwong L.M., Miller A.J., Lubinus P. A modular distal fixation option for proximal bone loss in revision total hip arthroplasty: a 2-to 6-year follow-up study. J Arthroplasty. 2003;18(3):94. doi: 10.1054/arth.2003.50083. [DOI] [PubMed] [Google Scholar]
  • 37.Rodriguez J.A., Fada R., Murphy S.B., Rasquinha V.J., Ranawat C.S. Two-year to five-year follow-up of femoral defects in femoral revision treated with the link MP modular stem. J Arthroplasty. 2009;24(5):751. doi: 10.1016/j.arth.2008.09.011. [DOI] [PubMed] [Google Scholar]
  • 38.Amanatullah D.F., Howard J.L., Siman H., Trousdale R.T., Mabry T.M., Berry D.J. Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component. Bone Joint J. 2015;97(3):312. doi: 10.1302/0301-620X.97B3.34684. [DOI] [PubMed] [Google Scholar]
  • 39.Houdek M.T., Perry K.I., Wyles C.C., Berry D.J., Sierra R.J., Trousdale R.T. Use of a modular tapered fluted femoral component in revision total hip arthroplasty following resection of a previously infected total hip: minimum 5-year follow-up. J Arthroplasty. 2015;30(3):435. doi: 10.1016/j.arth.2014.08.012. [DOI] [PubMed] [Google Scholar]
  • 40.Sarangi P., Bannister G. Leg length discrepancy after total hip replacement. Hip Int. 1997;7(3):121. [Google Scholar]
  • 41.Accuracy of X-ray based leg length and offset measurements in total hip arthroplasties. Haimerl M., Poitzsch L., Gneiting S., editors. Orthop Proc. 2012 [Google Scholar]
  • 42.Liebs T., Nasser L., Herzberg W., Rüther W., Hassenpflug J. The influence of femoral offset on health-related quality of life after total hip replacement. Bone Joint J. 2014;96(1):36. doi: 10.1302/0301-620X.96B1.31530. [DOI] [PubMed] [Google Scholar]
  • 43.Group RTHAS A comparison of modular tapered versus modular cylindrical stems for complex femoral revisions. J Arthroplasty. 2013;28(8):71. doi: 10.1016/j.arth.2013.04.052. [DOI] [PubMed] [Google Scholar]
  • 44.Sporer S., Paprosky W. Femoral fixation in the face of considerable bone loss. Clin Orthop Relat Res. 2004;429:227. doi: 10.1097/01.blo.0000150120.80409.0d. [DOI] [PubMed] [Google Scholar]
  • 45.Munro J.T., Garbuz D.S., Masri B.A., Duncan C.P. Tapered fluted titanium stems in the management of Vancouver B2 and B3 periprosthetic femoral fractures. Clin Orthop Relat Res. 2014;472(2):590. doi: 10.1007/s11999-013-3087-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Richards C.J., Duncan C.P., Masri B.A. Femoral revision hip arthroplasty: a comparison of two stem designs. Clin Orthop Relat Res. 2010;468(2):491. doi: 10.1007/s11999-009-1145-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Van Houwelingen A.P., Duncan C.P., Masri B.A. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10 years followup. Clin Orthop Relat Res. 2013;471(2):454. doi: 10.1007/s11999-012-2552-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Lakstein D., Eliaz N., Levi O. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am. 2011;93(1):57. doi: 10.2106/JBJS.I.01589. [DOI] [PubMed] [Google Scholar]
  • 49.Guo L., Yang Y., An B. Risk factors for dislocation after revision total hip arthroplasty: a systematic review and meta-analysis. Int J Surg. 2017;38:123. doi: 10.1016/j.ijsu.2016.12.122. [DOI] [PubMed] [Google Scholar]
  • 50.Mulay S., Hassan T., Birtwistle S., Power R. Management of types B2 and B3 femoral periprosthetic fractures by a tapered, fluted, and distally fixed stem. J Arthroplasty. 2005;20(6):751. doi: 10.1016/j.arth.2004.11.020. [DOI] [PubMed] [Google Scholar]
  • 51.Archibeck M.J., Rosenberg A.G., Berger R.A., Silverton C.D. Trochanteric osteotomy and fixation during total hip arthroplasty. J Am Acad Orthop Surg. 2003;11(3):163. doi: 10.5435/00124635-200305000-00003. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Conflict of Interest Statement for Jayasinghe
mmc1.docx (9KB, docx)
Conflict of Interest Statement for Maling
mmc2.docx (9KB, docx)
Conflict of Interest Statement for Vinayakam
mmc3.docx (9KB, docx)
Conflict of Interest Statement for Slack
mmc4.docx (9KB, docx)
Conflict of Interest Statement for Anibueze
mmc5.docx (9KB, docx)
Conflict of Interest Statement for Buckle
mmc6.docx (9KB, docx)
Conflict of Interest Statement for To
mmc7.docx (9KB, docx)