Abstract
Context:
Shoulder external rotators are challenged eccentrically throughout the deceleration phase of throwing, which is thought to contribute to overuse injuries. To evaluate the effectiveness of intervention programs, as well as identifying deficits, reliable and responsive measures of isometric and eccentric shoulder external rotation are necessary. Previously, isometric measures have primarily tested a single position, and eccentric measures have not been found to have high reliability.
Objective:
To examine the between-days reliability of multiple-angle isometric and dynamic eccentric isokinetic testing of shoulder external rotation.
Design:
Repeated measures.
Participants:
10 healthy subjects (age 30 ± 12 y, height 166 ± 13 cm, mass 72 ± 10 kg).
Main Outcome Measures:
Average isometric peak torque of shoulder external rotation at 7 angles was measured. From these values, the angle of isometric peak torque was calculated. Dynamic eccentric average peak torque, average total work, and average angle of peak torque were measured.
Results:
Between-days reliability was high for average peak torque during isometric contractions at all angles (ICC ≥ .85), as it was for dynamic eccentric average peak torque (ICC ≥ .97). The estimated angle of isometric peak torque (ICC ≤ .65) was not highly reliable between days. The average angle of peak torque from the eccentric testing produced inconsistent results. Average total work of dynamic eccentric shoulder external rotation was found to be highly reliable between days (ICC ≥ .97).
Conclusion:
Aspects of force such as peak torque and total work in isometric and eccentric testing of the shoulder external-rotator muscles can be measured reliably between days and used to objectively evaluate shoulder strength and identify changes when they occur. Angle measurements of peak torque could provide insight into the mechanical properties of the posterior shoulder muscles but were found to be inconsistent between days.
Keywords: strength testing, assessment, muscle strength, physical impairment
Shoulder pathology is one of the most common ailments in both athletes and the general population.1,2 Whether due to work or sport-related activity, there are often imbalances in the shoulder musculature that can lead to maladaptive changes that can become the primary source of pain.3–5 The shoulder external rotators are challenged eccentrically throughout the deceleration phase of throwing, which is thought to contribute to overuse injuries.6 In a similar manner, repetitive selective training of the internal rotators, such as what occurs during the swimming motion, has also been shown to result in muscle imbalances in the shoulder and subsequently chronic shoulder pain.3 To evaluate the effectiveness of intervention programs, as well as identify deficits, reliable and responsive measures of isometric and eccentric shoulder external rotation are necessary. Previously, isometric measures have been found to be reliable but have primarily been tested in a single position that does not provide strength assessment throughout the arc of motion. Concentric measures have also been found to be reliable for assessing shoulder internal and external rotation.7,8 Eccentric measures, however, have not been found to be consistently reliable.9–11 This could be attributable to the complexity and novelty of eccentric movements for many subjects during testing.
The purpose of this study was to examine the between-days reliability of 7 isometric angles to estimate angle of peak torque and, furthermore, to examine reliability between days for dynamic eccentric isokinetic testing of shoulder external rotation. By establishing reliable measures, these procedures can be used to evaluate effectiveness of intervention programs addressing shoulder external rotation. Determining the reliability for dynamic eccentric isokinetic testing was especially important to this study, as this method has been determined to be inconsistent in previous studies.
Methods
Ten participants (age 30 ± 12 y, height 166 ± 13 cm, mass 72 ± 10 kg) volunteered for this study from a sample of convenience at a university setting. Subjects were excluded from participation if they reported a history of shoulder or neck pathology, previous shoulder or neck surgery, or shoulder or neck pain within the last 6 months. Eligible subjects completed a Penn Shoulder Scale before testing to evaluate level of shoulder function before participation in the study. The mean Penn Shoulder Score was 99 with a range (94–100) indicating that participants demonstrated normal function at the onset of the study. All subjects read and signed a University of Kentucky Institutional Review Board–approved informed consent before participation in the study.
This study was designed to establish that shoulder external-rotation isometric measures of average peak torque and an estimate of the isometric angle of peak torque, using a second-order polynomial, could be measured reliably between days. In addition, dynamic eccentric average peak torque (DEAPT), average total angular impulse, and angle of peak torque were measured to determine the reliability of eccentric shoulder external-rotation measures across 3 weeks of testing. In total, 11 different measures were used to establish the reliability of our testing procedures. Previous research9,12 has examined isometric peak torque in 1 or 2 positions, but the current study used 7 different positions of isometric external rotation in addition to analyzing the estimated angle of isometric peak torque, DEAPT, average total angular impulse, and dynamic eccentric angle of peak torque. The independent variable was time. The dependent measures are isometric external-rotation average peak torque at 7 angles (external rotation 45°, 30°, 15°, 0°; internal rotation 15°, 30°, 45°), estimated angle of isometric peak torque, DEAPT, average total angular impulse, and average angle of peak torque.
Before each day of shoulder external-rotation testing all participants completed a warm-up of 3 shoulder stretches for the posterior and anterior shoulder musculature, with each stretch repeated twice for 30 seconds. Participants then warmed up with 2 active arm motions of side-lying external/internal rotation and side-lying horizontal abduction/adduction without resistance for 1 minute each.
All shoulder-strength testing was performed using an isokinetic dynamometer (Cybex Norm, Ronkonkoma, NY). Participants were positioned in the scapular-plane neutral position while seated with their dominant shoulder in 60° of abduction and 30° of horizontal adduction (see Figures 1 and 2). This testing position is a slight modification from the methods of previous studies.9,12 The positions were confirmed with a universal goniometer. Isometric testing was performed first, and angle of testing was randomly assigned using a random-number generator in Microsoft Excel on each testing day to minimize fatigue bias.
Figure 1 —

Frontal view of testing setup.
Figure 2 —

Transverse view of testing setup.
Isometric testing was completed in 7 different positions. In each position, subjects performed 1 submaximal practice repetition for 3 seconds, rested for 20 seconds and then performed 2 maximal repetitions for 3 seconds with a 60-second rest between trials.13 Standardized verbal encouragement was given during isometric strength testing to attempt to maximize the subject’s effort and strength potential.14 Peak torque values of the 2 contractions were averaged to represent an individual’s effort at each angle. The average torque at each angle was used for statistical analysis to determine isometric reliability.
In addition to calculating the average torque, isometric data at each angle were scatter plotted in Microsoft Excel for each trial. A second-order polynomial regression line was plotted and the angle of peak torque was estimated from this curve for both trials. This method has been previously described by Butterfield and Herzog15 to determine angle of peak torque from isometric contractions in an animal model.
Dynamic eccentric shoulder external-rotation data were collected in the same arm position and through 55° of external rotation to 55° of internal rotation. The continuous-passive-motion mode was used for testing. The internal-rotation velocity was set at 60°/s for internal rotation, in which the subject was instructed to maximally contract into external rotation just before initiation of internal rotation. The subject was instructed to maximally resist internal rotation through the entire range of motion to evaluate eccentric external-rotation strength. The subject was instructed to relax the arm as it was passively returned into external rotation by the device at 15°/s to eliminate all concentric activity. Subjects were allowed 3 practice trials to familiarize themselves with this novel movement. After 3 minutes of rest, subjects performed 6 maximal efforts in a row with 7 seconds of recovery during the passive return to full external rotation between trials. The middle 4 of the 6 trials were averaged and used in statistical analysis for DEAPT, average total angular impulse, and average angle of peak torque. Standardized verbal encouragement was given for all eccentric testing.14
Subjects returned to the laboratory for collection of the same data 1 week from the initial testing and again 2 weeks from the initial testing, for a total of 3 tests. Three sessions were performed to investigate the potential effect of motor learning that can have while undergoing strength testing, particularly for a novel task such as maximal eccentric contractions. These data for the 3 sessions were used to establish reliability of testing between days 1 and 2 and days 2 and 3. Independent intraclass correlation coefficients (ICCs) were used to examine between-days reliability for all dependent measures. A 2-way random model consistent with an ICC2,k was performed using SPSS version 22 (IBM, Armonk, NY).16
Results
Descriptive data for all 11 dependent measures are presented as means and SDs in Table 1. Isometric shoulder external-rotation average peak torque proved to be a very reliable measure for all tested angles between days 1 and 2 and days 2 and 3 (ICC ≥ .85) (Table 2). The estimated angle of isometric peak torque calculated from the isometric contractions at 7 angles was not reliable between days 1 and 2 (ICC = −.003) but had fair reliability between days 2 and 3 (ICC = .65). Dynamic eccentric average total angular impulse and average peak torque were reliable between days 1 and 2 and days 2 and 3 (Table 2). The average angle of peak torque measured from dynamic shoulder eccentric external rotation had excellent reliability between days 1 and 2 (ICC = .93) but was only fair between days 2 and 3 (ICC = .51).
Table 1.
Isometric and Eccentric Mean Values
| Measure | Day 1 | Day 2 | Day 3 | |||
|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | SD | |
| Isometric measures (Nm) | ||||||
| external rotation 45° | 15.4 | 6.2 | 14.7 | 5.8 | 15.7 | 7.4 |
| external rotation 30° | 16.5 | 6.5 | 16.4 | 5.9 | 16.7 | 7.8 |
| external rotation 15° | 18.1 | 6.5 | 16.9 | 6.2 | 18.3 | 9.7 |
| 0° | 17.9 | 6.7 | 17.8 | 6.9 | 18.5 | 8.1 |
| internal rotation 15° | 20.4 | 8.9 | 17.8 | 7.3 | 19.7 | 8.8 |
| internal rotation 30° | 20.4 | 8.7 | 20.1 | 8.9 | 20.4 | 9.7 |
| internal rotation 45° | 20.7 | 10.5 | 20.4 | 9.4 | 21.3 | 10.2 |
| estimated angle of peak torque (°) | 14.7 | 73.8 | 37.2 | 166.6 | 20.8 | 83.4 |
| Eccentric measures | ||||||
| peak torque (Nm) | 22.9 | 8.0 | 22.8 | 7.4 | 23.8 | 8.6 |
| average angular impulse (Nm × s) | 32.1 | 11.9 | 31.8 | 11.0 | 34.1 | 12.9 |
| average angle of peak torque (°) | −11.1 | 26.5 | −5.0 | 24.0 | −12.0 | 18.4 |
Table 2.
Between-Days Reliability Values of Isometric and Eccentric Shoulder External Rotation
| Measure | Day | ICC | SEM | MDC |
|---|---|---|---|---|
| Isometric measures (Nm) | ||||
| external rotation 45° | 1–2 | .92 | 1.7 | 2.4 |
| 2–3 | .90 | 2.1 | 3.0 | |
| external rotation 30° | 1–2 | .85 | 2.4 | 3.4 |
| 2–3 | .91 | 2.0 | 2.8 | |
| external rotation 15° | 1–2 | .96 | 1.3 | 1.8 |
| 2–3 | .90 | 2.5 | 3.5 | |
| 0° | 1–2 | .97 | 1.2 | 1.7 |
| 2–3 | .93 | 2.0 | 2.9 | |
| internal rotation 15° | 1–2 | .93 | 2.1 | 3.0 |
| 2–3 | .95 | 1.8 | 2.6 | |
| internal rotation 30° | 1–2 | .99 | 0.9 | 1.3 |
| 2–3 | .99 | 1.1 | 1.6 | |
| internal rotation 45° | 1–2 | .97 | 1.7 | 2.5 |
| 2–3 | .97 | 1.7 | 2.4 | |
| estimated angle of peak torque (°) | 1–2 | −.003 | 120.4 | 170.2 |
| 2–3 | .65 | 73.9 | 104.6 | |
| Eccentric measures | ||||
| peak torque (Nm) | 1–2 | .97 | 1.3 | 1.8 |
| 2–3 | .98 | 1.2 | 1.7 | |
| average angular impulse (Nm × s) | 1–2 | .97 | 2.0 | 2.8 |
| 2–3 | .98 | 1.9 | 2.7 | |
| average angle of peak torque (°) | 1–2 | .93 | 6.5 | 9.2 |
| 2–3 | .51 | 14.8 | 20.9 |
Abbreviations: ICC, intraclass correlation coefficient; SEM, standard error of measurement; MDC, minimal detectable change.
Discussion
The results of this study demonstrated that measures of force in isometric shoulder external-rotation average peak torque, dynamic eccentric average peak torque, and dynamic eccentric average total angular impulse can be measured reliably between days. However, the angle of peak torque predicted from 7 angles of isometric contractions and average angle of peak torque during dynamic eccentric testing were found to have greater variability and were not consistent measures. The ability to consistently produce force in external rotation is very good in shoulder external rotation; however, the findings of this study suggest that in the general population of healthy shoulders the angle at which peak torque can be produced is not well controlled in external rotation. Mean and peak torque values are better and more reliable for measuring strength changes than using angle measurements.
To the best of our knowledge, this is the first study to assess isometric shoulder external-rotation strength at multiple angles throughout the middle arc of shoulder range of motion. Previous studies have determined that isometric shoulder external rotation can be measured reliably at a single angle or in a few positions. Malerba et al9 reported ICC values ≥.81 for isometric external rotation at 20° and 60° of shoulder external rotation using an isokinetic dynamometer with the arm positioned in 45° of abduction, 30° of horizontal adduction, and 90° of elbow flexion, which is similar to our current study. Similarly, MacDermid et al12 reported an ICC of .90 in their study when evaluating external rotation using an isokinetic dynamometer at 0° of shoulder external rotation and the same arm positioning as was used in a study by Malerba et al.9 We tested 7 different angles to estimate the isometric angle of peak torque.15 This provides a more comprehensive assessment of shoulder strength throughout the range of motion, as well as a more accurate portrayal of the mechanical properties of the muscles being tested. For this reason, it was important to establish that isometric peak torque could be measured reliably at each angle to accurately assess strength changes throughout the range of motion.
The results of this study demonstrated good test–retest reliability for isometric shoulder external-rotation peak torque at all 7 angles. The reliability of our study was consistently high, with low measurement error ranging from 0.9 to 2.5 Nm at all angles between days and values generated were similar to those in previous studies, so we are confident that with values of approximately 1.3 to 3.5 Nm representing minimal detectable change (MDC), this testing procedure would be able to detect a change in strength when one occurs. Measuring at multiple angles will help provide a more complete representation of muscle function throughout the arc of motion and may allow us to identify deficits in an injured population in the future.
The average total impulse and average peak torque for dynamic eccentric shoulder external rotation were found to be reliable. While the results of previous studies are inconsistent, our study revealed that these aspects of eccentric shoulder external rotation can be measured reliably. Edouard et al11 demonstrated ICC results comparable to those in the current study, ranging from .87 to .97. Using similar testing methods, however, eccentric testing was performed at a slower speed of 30°/s across 70° of motion and resistance was performed in 2 directions. The slower speed of movement may have improved consistency of torque output, as the subjects had over 2 seconds of eccentric resistance in both directions. Contrary to these results, Malerba et al9 reported ICC values for the between-days reliability of eccentric average work and peak torque to be equal to .58 and .44, respectively, using a similar testing method as Edouard but at a speed of 60°/s, which is similar to the current study. However, Malerba et al9 tested subjects across pain-free arcs of motion, not defined by the investigators, which could have affected their reliability and torque outputs. Those authors further speculated that their low ICC values were due to the complexity of the eccentric testing and the subjects’ unfamiliarity with the movement. We agree with this statement and in our study limited cognitive demand by only testing eccentric external rotation. No other dynamic motions were tested, which may account for our higher reliability values for eccentric testing.
In the literature, total work and total impulse are used synonymously to define the area under the curve. In the study of Malerba et al,9 total work was defined as the area under the torque curves where work was equal to the magnitude of the force times the distance, where the distance was the angular displacement of the limb. For our study, this same measurement was termed total angular impulse to better represent the area under the curve as the product of the torque applied by the subject multiplied by its time of application: 0.5(torque at point A + torque at point B) × .01.17 These measurements of work and angular impulse are comparable and vary only based on the units used for the calculation. For the purpose of this study, time was used, whereas Malerba et al used a unit of distance to report the changes in torque. They reported that the measurement error was equal to 26.3 Nm × s with a minimal detectable change of 37.2 Nm × s, while the standard error of measurement (SEM) for average peak torque was equal to 10.8 Nm, and the MDC, 15.3 Nm.
In addition to the high reliability values for dynamic eccentric average total angular impulse and average peak torque, the results of our study also had relatively low measurement error (SEM ≤ 2.0 Nm × s) and minimal detectable change (MDC ≤ 2.8 Nm × s). The combination of these 3 variables contributes to the ability of these testing methods to be used as a tool to evaluate subtle changes in shoulder external-rotation strength, particularly in the ability to see changes at any point throughout the range of motion. Analyzing the average total angular impulse offers a more complete representation of the amount of effort throughout the entire arc of motion tested, as opposed to the peak torque, which represents only a single point in the arc of motion during dynamic eccentric testing. By examining the total arc of motion, deficits and improvement can be readily identified during testing and rehabilitation process.
As mentioned previously, studies have demonstrated that shoulder internal- and external-rotation strength measurements are reliable when tested concentrically. Mandalidis et al10 tested subjects using a Kincom II dynamometer in a testing position similar to the one used in our current study. Across 60° of shoulder rotation, concentric measures for all subjects’ mean peak and average moment produced ICC values greater than .80, whereas ICC values for the eccentric measures were greater than .76. Our study revealed ICC values ranging from .97 to .98 for dynamic eccentric peak torque and average angular impulse. Although it is difficult to make direct comparisons between the 2 studies as different outcome measures were used for each, it is important to recognize the improved reliability of eccentric measures in the current study.
The average between-days reliability for angle of peak torque during dynamic eccentric shoulder external rotation was fair. When analyzing the results of day 1 to day 2, a high reliability value is reported (ICC = .93). However, from day 2 to day 3, the reliability is considerably lower (ICC = .51), resulting in an average ICC of .72. This variability can be accounted for through analysis and recognition of outliers in the data. When the single outlier is removed, the average ICC value improves to .88. In addition to the removal of the outlier, it is important to note the great amount of variability present in the angle measurements during isokinetic testing. Our study reported SEM values ranging from 6.5° to 14.8° for this measurement. The use of human subjects also greatly increases the chances that external factors may contribute to the variability such as was observed in our study. Motivation and incentive can alter a subject’s performance on maximal-effort tests. We attempted to control for these factors by using standardized verbal encouragement, which has been shown to improve performance.14 Despite our best efforts, it is possible that variations in these factors could influence each subject’s performance during testing and consequently where the angle of peak torque occurs dynamically.
Using the average torque values from the 7 angles of isometric testing, we were able to calculate the predicted angle at which the shoulder external rotators would generate the greatest force. This value, however, produced a poor reliability measure. It is interesting to note the mechanical properties of the posterior shoulder musculature that are demonstrated in the results of our study. Previous studies have found that muscles are less capable of generating maximal forces at longer lengths. This has been well established in the quadriceps muscle. In 1 study, Babault et al18 found that the knee-extensor torque produced by human subjects during isometric maximal voluntary contraction was significantly lower when the leg was close to full extension. However, in the current study, we found that even at greater lengths the posterior shoulder muscles working synergistically were able to maintain or continue generating an equal amount of force (Figure 3). While the reliability of the predicted angle was poor, we believe this finding to still be of great importance in assessing the mechanical properties of the posterior shoulder muscles.
Figure 3 —

Force–length relationship of a single subject. Graphic representation of isometric strength testing of the 7 angles tested ranging from 45° external rotation to 45° internal rotation. Second-order polynomial trend line was plotted to represent the torque generated across the arc of motion. Arm position, in degrees of internal and external rotation, is plotted on the horizontal axis, while torque, in Newton meters, is on the vertical axis.
There are several limitations to this study. Our sample population consisted solely of healthy subjects and testing was conducted on the dominant extremity only. Training status of each subject was also not identified as a determining factor for inclusion in the study. It is unknown whether we would obtain similar results if the subjects’ level of training before the study were assessed. We measured shoulder external rotation, not a particular individual muscle such as the infraspinatus or trapezius. Therefore we cannot attribute performance to a specific muscle, as the scapulohumeral and axioscapular muscles work synergistically to perform shoulder external rotation. The small sample size of this study also raises some concerns in the confidence of our results. Despite the small sample size, especially in comparison with similar studies, further analysis of our data determined there was no change in the ICC values when a single subject was removed. To establish greater reliability, research is needed with an increased sample size.
In this study we have shown that isometric and dynamic eccentric average total angular impulse and average peak torque can be measured reliably for shoulder external rotation. All of these measures were found to demonstrate low measurement error, indicating that the measurement methods could effectively detect strength changes from training or identify deficits when they occur. Fair reliability was demonstrated for the average angle of peak torque during eccentric external rotation. While the estimated angle of isometric peak torque demonstrated poor reliability, this measure has been used by previous researchers19 to show the effects of eccentric training and could provide further insight into the mechanical properties of the posterior shoulder muscles, but caution should be exercised in using this measure to evaluate change over time due to inconsistency of the measure in shoulder external rotation.
Acknowledgments
The project described was supported by the National Center for Advancing Translational Sciences, National Institutes of Health, through grant number UL1TR000117. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.
References
- 1.Luime JJ, Koes BW, Hendriksen IJ, et al. Prevalence and incidence of shoulder pain in the general population; a systematic review. Scand J Rheumatol. 2004;33(2):73–81. doi: 10.1080/03009740310004667 [DOI] [PubMed] [Google Scholar]
- 2.McFarland EG, Wasik M. Epidemiology of collegiate baseball injuries. Clin J Sport Med. 1998;8(1):10–13. doi: 10.1097/00042752-199801000-00003 [DOI] [PubMed] [Google Scholar]
- 3.Rupp S, Berninger K, Hopf T. Shoulder problems in high level swimmers—impingement, anterior instability, muscular imbalance? Int J Sports Med. 1995;16(8):557–562. doi: 10.1055/s-2007-973054 [DOI] [PubMed] [Google Scholar]
- 4.Ludewig PM, Borstad JD. Effects of a home exercise programme on shoulder pain and functional status in construction workers. Occup Environ Med. 2003;60(11):841–849. doi: 10.1136/oem.60.11.841 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Frost P, Bonde JP, Mikkelsen S, et al. Risk of shoulder tendinitis in relation to shoulder loads in monotonous repetitive work. Am J Ind Med. 2002;41(1):11–18. doi: 10.1002/ajim.10019 [DOI] [PubMed] [Google Scholar]
- 6.Fleisig GS, Andrews JR, Dillman CJ, Escamilla RF. Kinetics of baseball pitching with implications about injury mechanisms. Am J Sports Med. 1995;23(2):233–239. doi: 10.1177/036354659502300218 [DOI] [PubMed] [Google Scholar]
- 7.Hill A, Pramanik S, McGregor A. Isokinetic dynamometry in assessment of external and internal axial rotation strength of the shoulder: comparison of two positions. Isokinet Exerc Sci. 2005;13(3):187–195. [Google Scholar]
- 8.Anderson VB, Bialocerkowski AE, Bennell KL. Test–retest reliability of glenohumeral internal and external rotation strength in chronic rotator cuff pathology. Phys Ther Sport. 2006;7(3):115–121. doi: 10.1016/j.ptsp.2006.04.002 [DOI] [Google Scholar]
- 9.Malerba JL, Adam ML, Harris BA, Krebs DE. Reliability of dynamic and isometric testing of shoulder external and internal rotators. J Orthop Sports Phys Ther. 1993;18(4):543–552. doi: 10.2519/jospt.1993.18.4.543 [DOI] [PubMed] [Google Scholar]
- 10.Mandalidis DG, Donne B, O’Regan M, O’Brien M. Reliability of isokinetic internal and external rotation of the shoulder in the scapular plane. Isokinet Exerc Sci. 2001;9:65–72. [Google Scholar]
- 11.Edouard P, Codine P, Samozino P, Bernard PL, Herisson C, Gremeaux V. Reliability of shoulder rotators isokinetic strength imbalance measured using the Biodex dynamometer. J Sci Med Sport. 2013;16(2):162–165. [DOI] [PubMed] [Google Scholar]
- 12.MacDermid JC, Ramos J, Drosdowech D, Faber K, Patterson S. The impact of rotator cuff pathology on isometric and isokinetic strength, function, and quality of life. J Shoulder Elbow Surg. 2004;13(6):593–598. [DOI] [PubMed] [Google Scholar]
- 13.Philippou A, Bogdanis GC, Nevill AM, Maridaki M. Changes in the angle–force curve of human elbow flexors following eccentric and isometric exercise. Eur J Appl Physiol. 2004;93(1–2):237–244. doi: 10.1007/s00421-004-1209-z [DOI] [PubMed] [Google Scholar]
- 14.McNair PJ, Depledge J, Brettkelly M, Stanley SN. Verbal encouragement: effects on maximum effort voluntary muscle action. Br J Sports Med. 1996;30(3):243–245. doi: 10.1136/bjsm.30.3.243 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Butterfield TA, Herzog W. Is the force–length relationship a useful indicator of contractile element damage following eccentric exercise? J Biomech. 2005;38(9):1932–1937. doi: 10.1016/j.jbiomech.2004.08.013 [DOI] [PubMed] [Google Scholar]
- 16.Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86(2):420–428. doi: 10.1037/0033-2909.86.2.420 [DOI] [PubMed] [Google Scholar]
- 17.Kreighbaum E, Barthels KM. Biomechanics: A Qualitative Approach for Studying Human Movement. 4th ed. Needham Heights, MA: Allyn & Bacon; 1996. [Google Scholar]
- 18.Babault N, Pousson M, Michaut A, Van Hoecke J. Effect of quadriceps femoris muscle length on neural activation during isometric and concentric contractions. J Appl Physiol. 2003;94(3):983–990. doi: 10.1152/japplphysiol.00717.2002 [DOI] [PubMed] [Google Scholar]
- 19.Brockett CL, Morgan DL, Proske U. Human hamstring muscles adapt to eccentric exercise by changing optimum length. Med Sci Sports Exerc. 2001;33(5):783–790. doi: 10.1097/00005768-200105000-00017 [DOI] [PubMed] [Google Scholar]
