Abstract
Our clinical case supports the effectiveness of distal His‐Bundle pacing in obtaining ventricular resynchronization in patients with LBBB and left ventricular dysfunction, particularly in the context of post‐TAVI conduction disturbances.
Keywords: cardiac resynchronization therapy, his‐bundle pacing, left bundle branch block, TAVI
Our clinical case supports the effectiveness of distal His‐Bundle pacing in obtaining ventricular resynchronization in patients with LBBB and left ventricular dysfunction, particularly in the context of post‐TAVI conduction disturbances.

1. INTRODUCTION
Transcatheter aortic valve implantation (TAVI) has experienced an impressive growth in recent years. New‐onset conduction disturbances with need for permanent pacing are relatively common after TAVI. We report a case of a permanent pacemaker implantation in a patient with (previous) left bundle branch block (LBBB), left ventricular ejection fraction (LVEF) of 32%, and high degree atrioventricular block (AVB) induced after TAVI, with His‐bundle capture resulting in the correction of the LBBB and LVEF improvement in the early postoperative period.
Surgical aortic valve replacement has been the gold standard treatment for severe aortic stenosis. With aging and increasingly multimorbidity of the western world population, alternative and less invasive procedures were developed. Transcatheter aortic valve implantation (TAVI) was first introduced in 2002 1 to further reduce surgical trauma and to avoid cardiopulmonary bypass. 2 After this first event, an impressive increase in annual worldwide implantations was observed, due to a favorable ratio of risk to benefit. 3 New‐onset conduction disturbances are relatively common after TAVI, with various reports in the literature documenting it in as much as 34.8% of patients at hospital discharge, 2 , 3 and with left bundle branch block (LBBB) being the most common significant conduction abnormality after TAVI (10.5%). His‐bundle pacing (HBP) is an effective alternative to right ventricular (RV) and biventricular pacing and is performed with the aim of maintaining a physiological pattern of ventricular activation, via the native His‐Purkinje system. 4
2. CASE PRESENTATION
A 83‐year‐old man was electively admitted for intervention and management of severe aortic stenosis with New York Heart Association class III heart failure. The preoperative electrocardiogram (ECG) showed sinus rhythm with LBBB (wQRS 150 ms) (Figure 1). Transthoracic echocardiography documented a calcified aortic valve, with reduced cusp excursion, with valve area of 0.7 cm2 and mean gradient of 41 mm Hg. Left ventricular ejection fraction (LVEF) was 32%, with akinesia of the inferior wall and septum, and moderate mitral regurgitation.
FIGURE 1.

Baseline ECG tracing, showing complete left bundle brunch block (QRS width 150 mseg)
Using a left femoral approach, an Edwards SAPIEN 3 26mm Transcatheter Heart Valve was deployed without complications and with need of postdilatation. As per protocol, a temporary pacing wire was left at the RV apex. At the time of TAVI, the patient maintained LBBB. Within the first 24 hours post‐TAVI, the patient developed episodes of Mobitz 2 AVB and high‐grade AVB. In this clinical context, we decided to implant a permanent pacemaker (pacing without ICD due to advanced age and significant comorbidities). Via the left subclavian vein, 3 catheters were introduced (atrial lead, His capture lead, and RV apical lead as backup). For His pacing, a fixed curve C315 His sheath (Medtronic®) and a 3830 Select Secure lead (Medtronic®) was used. Operating the pacing lead alone, with unipolar mapping connected to the pacing system analyzer atrial channel (at a gain setting of 0.05 mV/mm and a sweep speed of 50 mm/sec), the intracavitary electrograms showed a slightly prolonged HV interval (62 ms), with a double His potential (Figure 2). Pacing with capture in the proximal His location was obtained at a threshold less than 1 V, but without recruitment of the left bundle branch. Correction of LBBB (Figure 3) occurred at 3 V at 1 ms. A Medtronic® 4076 active fixation lead was then placed in apical RV, with a threshold 0.75 V at 0.5 ms, and a Medtronic® 4076 lead was placed at the right atrial appendage, with a threshold 1.5 V at 0.5 ms.
FIGURE 2.

Intracardiac recording (with the pacing lead), depicting the intrahisian conduction delay (splitting of the His potential)
FIGURE 3.

Fluoroscopy image showing the final position of the pacing leads. His lead (white arrow)
The leads were connected to a Medtronic® Serena biventricular generator (CRT‐P). RV lead was connected to the RV port for ventricular sensing and backup pacing (in case of loss of His lead capture), and His lead was connected to the left ventricular port. The device was programmed to DDD(R) biventricular pacing, with HBP (programed at 6 mV/1 ms) delivered before RV pacing (interventricular delay set to the maximum value of 80 ms).
Paced QRS duration was 90 ms on the ECG (Figure 4), consistent with “His resynchronization” 5 After the pacing spike, an initial pseudodelta wave is observed, due to the simultaneous capture of the neighboring myocardium and recruitment of the His‐Purkinje system.
FIGURE 4.

ECG tracing showing ventricular pacing with His‐bundle capture (nonselective) and QRS width of 90 ms
Transthoracic echocardiography, repeated 48 hours after pacing implantation, showed improvement in overall systolic function (LVEF 44%), without evidence of desynchrony and a normal prosthetic valve function.
At 6 months follow‐up, the pacing threshold stabilized at 2 V at 1 ms
3. DISCUSSION
Transcatheter aortic valve implantation has revolutionized the management of aortic stenosis and become the standard of care for patients with aortic stenosis at prohibitive surgical risk, and the preferred treatment for many intermediate and high‐risk elderly patients. 6
His‐bundle pacing has the potential to offer ventricular resynchronization, since significant reductions in QRS duration have been observed when stimulating the His‐Purkinje system in patients with LBBB. 7
In the present case, the proximal His recording revealed a split His potential, which is highly suggestive of the presence of intrahisian disease. Pacing slightly distally from this site resulted also in correction of the LBBB (with an evident narrowing of the QRS width from 150 ms to 90 ms). In patients with LBBB, conduction system pacing can deliver cardiac resynchronization therapy by correcting BBB (multi‐layer block with bundle recruitment) to synchronize ventricular activation. 8 “Bundle recruitment” refers to capture of the previously nonfunctional conduction fibers.
Recently, 9 some authors proposed LBB direct pacing (with a lead traversing the interventricular septum), as an option with a lower pacing threshold, that also has the advantage of avoiding later deterioration at the proximal His‐bundle or AV node caused by the progression of AV conduction delay.
Our clinical case supports the potential effectiveness of HBP in obtaining ventricular resynchronization for patients with LBBB and left ventricular dysfunction, particularly in the context of post‐TAVI conduction disturbances.
4. CONCLUSION
Conduction abnormalities after TAVI are relatively common and frequently have indication for implantation of a permanent pacemaker. Although it may not be generalized to all post‐TAVI cases as the block induced mechanically by the valve may be more distal regarding the His‐Purkinge system, His pacing may be useful in the treatment of patients with LBBB and AV conduction disturbance after TAVI with the recruitment of the intrinsic conduction tissue and normalization of intraventricular conduction. This pacing modality reduces the electromechanical desynchrony associated with conventional right ventricular pacing, which could be potentially beneficial in the particularly vulnerable group of aortic stenosis patients treated with TAVI.
CONFLICT OF INTEREST
The authors have no conflict of interest to declare.
AUTHOR CONTRIBUTIONS
PSC and MMO: designed and directed the project. JP and PSC: collected the data. PSC: wrote the manuscript with support from JP and MMO.
ETHICAL APPROVAL
Written informed consent was obtained from the patient for the publication of this case report.
ACKNOWLEDGMENTS
No acknowledgments to report.
Silva Cunha P, Pais J, Oliveira MM. His‐bundle pacing as an alternative to CRT in a patient with left bundle branch block, left ventricular dysfunction, and TAVI‐induced complete AV block. Clin Case Rep. 2021;9:2245–2248. 10.1002/ccr3.4000
Funding information
The write up of this report was self‐funded by the authors involved.
DATA AVAILABILITY STATEMENT
Patient data are available.
REFERENCES
- 1. Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106:3006‐3008. [DOI] [PubMed] [Google Scholar]
- 2. Khosravi A, Wendler O. TAVI 2018: from guidelines to practice. E‐J Cardiol Pract. 2018;15:29. www.escardio.org. [Google Scholar]
- 3. Auffret V, Puri R, Urena M, et al. Conduction disturbances after transcatheter aortic valve replacement. Current status and future perspectives. Circulation. 2017;136:1049‐1069. [DOI] [PubMed] [Google Scholar]
- 4. Lewis A, Foley P, Whinnett Z, Keene D, Chandrasekaran B. His bundle pacing: a new strategy for physiological ventricular activation. J Am Heart Assoc. 2019;8:e010972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Arnold AD, Whinnett ZI, Vijayaraman P. His‐purkinje conduction system pacing: state of the art in 2020. Arrhythm Electrophysiol Rev. 2020;9(3):136‐145. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Cahill TJ, Chen M, Hayashida K, et al. Transcatheter aortic valve implantation: current status and future perspectives. Eur Heart J. 2018;39(28):2625‐2634. [DOI] [PubMed] [Google Scholar]
- 7. Teng AE, Lustgarten DL, Vijayaraman P, et al. Usefulness of His bundle pacing to achieve electrical resynchronization in patients with complete left bundle branch block and the relation between native QRS axis, duration, and normalization. Am J Cardiol. 2016;118:527‐534. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Arnold AD, Shun‐Shin MJ, Keene D, et al. His resynchronization versus biventricular pacing in patients with heart failure and left bundle branch block. J Am Coll Cardiol. 2018;72:3112‐3122. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Huang W, Su L, Wu S, et al. A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block. Can J Cardiol. 2017;33:1736.e1‐1736.e3. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Patient data are available.