Abstract
Positive anti-human leukocyte antigen (HLA) antibodies are considered a contraindication for cardiac transplantation in India, due to its negative impact on cardiac allograft survival and increased chances of rejection post-transplant. Single antigen bead (SAB) assay helps to further characterize these antibodies. Our case portrays India’s first reported successful cardiac transplant utilizing a virtual crossmatch (VXM)-based approach in a patient with positive anti-HLA antibody screen and SAB assay. We propose that adopting such an approach, in select cases, in India is certainly feasible. This approach would lead to increasing the potential donor pool and mitigate the chances of post-transplant rejection. With increased demands, the SAB assay cost would reduce, further improving its cost-effectiveness.
Keywords: Cardiac transplant, Rejection, Virtual crossmatch, SAB
Introduction
Anti-human leukocyte antigen (HLA) antibody screening is used to detect circulating anti-HLA antibodies in a transplant recipient’s serum. Pre-transplant anti-HLA antibodies can adversely impact cardiac allograft survival and rejection rates post-transplant [1]. A positive antibody screen also reduces the potential donor pool, thus increasing transplant wait time and wait-list mortality.
We present a cardiac transplant case with multiple pre-transplant antibodies, which was successfully managed utilizing “virtual” crossmatch (VXM) to optimize donor selection and pre-transplant de-sensitization to reduce the antibody burden.
Case report
A 62-year-old man with idiopathic restrictive cardiomyopathy was referred to our center with worsening New York Heart Association functional class IIIb dyspnea and multiple heart failure hospitalizations over 2 years. Echocardiogram demonstrated severe bi-ventricular dysfunction with restrictive physiology.
Right heart catheterization demonstrated severely reduced cardiac output (Fick 2.86 L/min) and acceptable pulmonary vascular resistance (3.1 WU). HLA antibody screening was positive for class 1 antibodies. In view of the positive anti-HLA antibody report, medical therapy was continued. The relatively small size of left ventricle and severe right ventricular dysfunction ruled out left ventricular assist device (LVAD) as a therapeutic option.
Patient declined clinically over next 6 months despite optimum medical therapy. Given the prior positive HLA antibody screen, a single antigen bead (SAB) assay was performed. The SAB assay (Immucor, USA) identified multiple class I anti-HLA antibodies (Mean Florescent Intensity {MFI} above 2000) and a single class II anti-HLA antibody (Table 1). Citing lack of other viable therapeutic modalities, we listed the patient for cardiac transplantation.
Table 1.
Single antigen bead (SAB) assay report (Luminex) with multiple un-acceptable class I and class II HLA antibodies in bold (MFI > 2000)
| HLA class I antibodies | MFI value |
| HLA-A*33:01 | 6670 |
| HLA-A*26:01 | 4908 |
| HLA-A*66:02 | 3803 |
| HLA-B*08:01 | 3362 |
| HLA-A*33:03 | 2981 |
| HLA-A*66:01 | 2218 |
| HLA-A*69:01 | 2212 |
| HLA-A*25:01 | 2181 |
| HLA-A*68:02 | 1863 |
| HLA-B*59:01 | 1532 |
| HLA class II antibody | MFI value |
| HLA-DQB1*04:01 | 2189 |
Within 2 months of listing, we received a favorable ABO-compatible deceased donor offer. Donor HLA antigen profile testing (Table 2) along with complement-dependent cytotoxicity (CDC) and Luminex platform-based crossmatches were performed prospectively. Virtual crossmatch using recipient SAB result and the donor HLA profile was performed and it revealed absence of donor-specific antibodies (DSA) at the allelic level. Finally, with the negative results of CDC, Luminex, and virtual crossmatch, the donor was deemed acceptable.
Table 2.
Donor HLA profile without any un-acceptable antigens when crossmatched with antibodies in Table 1
| A*68:01 | B*51:01 |
| B*07:05 | C*14:02 |
| C*07:01 | DRB1*15:01 |
| DRB1*04:04 | DQB1*06:01 |
| DQB1*03:02 |
Plasmapheresis was performed in the operating room, prior to the initiation of cardiopulmonary bypass. Intravenous rabbit anti-thymocyte globulin was used for induction immunosuppression. Transesophageal echocardiogram demonstrated normal bi-ventricular function. Post-operative plasmapheresis was not performed in view of negative DSA.
Patient was discharged home on standard maintenance immunosuppression comprising tacrolimus, prednisone, and mycophenolate mofetil. Endomyocardial biopsy performed at day 29 was negative for rejection. Repeat DSA testing was negative for de novo antibodies at 4 weeks, 3 months, 6 months, and 12 months post-transplant. Patient currently remains clinically stable, 13 months post-transplantation, with normal cardiac allograft function, without any episodes of cardiac rejection.
Discussion
Importance of anti-HLA antibodies for the survival of a transplanted kidney was first recognized by Patel et al. in 1969 [2]. This landmark study resulted in the routine use of CDC crossmatch in transplant patients to prevent hyperacute rejection and acute accelerated rejection. However, it is the least sensitive and specific of the current assays [3]. No single strategy for detecting pre-transplant antibodies is considered optimum, due to availability of multiple assays/platforms, with varying sensitivities and specificities and lack of large randomized controlled trials.
The International Society of Heart and Lung Transplantation (ISHLT) recommends (class IC) pre-transplant antibody screening in all prospective cardiac transplant candidates. If the antibody screening is positive, then further evaluation using SAB assay, solid-phase assays (flow cytometry or Luminex), and C1q assay is recommended [3]. However, the C1q assay is not readily available in India at this time.
According to the ISHLT guidelines, a VXM must be performed before a donor organ is allocated to a particular recipient [3, 4]. Currently in India, cardiac organ allocations occur on the basis of a single compatible ABO blood group crossmatch. The CDC, Luminex, and/or flow cytometry crossmatches are performed prior to the transplant. However, their results are available to the recipient team only when the cardiac transplant surgery is nearing completion or post-surgery.
Routine pre-transplant VXM requires close coordination and communication between the transplant team and histocompatibility team. It is ideal to perform flow cytometry or Luminex crossmatch along with the SAB assay. Often in India, VXM cannot be performed prior to the transplant due to time or infrastructure constraints. In such cases, we recommend performing HLA antibody screening, in addition to the CDC and Luminex crossmatch, with or without flow cytometry crossmatch, to rule out presence of DSA, which are detrimental to transplant outcomes. On the other hand, if a VXM is performed and is positive, then it is imperative to perform a prospective Luminex crossmatch and only proceed with transplant if the prospective crossmatch is negative.
The detection of anti-HLA antibodies is a crucial part of the evaluation and immune-monitoring of cardiac transplant recipients. The introduction of beads coated with HLA antigens has revolutionized the process of detection of these pre- and post-transplant antibodies. Luminex SAB assays are the most sensitive and specific of the bead assays [3]. The SAB assay results are expressed in terms of mean fluorescence intensity (MFI). In the absence of international standards, each transplant center has defined their own levels of accepted MFIs.
Immucor or One Lambda assay kits are commercially available and are widely used for performing the SAB assays. Studies comparing these assay kits showed similar results, especially in patients with moderate to high MFI [5, 6]. We acknowledge the known limitations of the SAB assays, such as the ability to detect antibodies that are reactive only to the antigens coated on the beads, without truly knowing the antigenic make-up of the Indian population pool. Further, in highly sensitized patients with high MFI values of more than 15,000 for several beads, it is necessary to dilute the sera for appropriate identification of antibodies. Thus, patients with low-avidity IgG and low-titer IgG can be missed in SAB assays in such instances.
Our patient demonstrated multiple pre-transplant anti-HLA antibodies. As explained above, cardiac transplant was the only remaining viable option. Meticulous donor selection utilizing VXM and planned pre-transplant de-sensitization strategies ensured a successful cardiac transplant.
Instead of an immunologically blind approach, we propose using a VXM-based approach in India, in this select group of patients, to help maximize our donor pool and mitigate rejection risk. Our case report is India’s first reported successful cardiac transplant case utilizing a VXM-based approach in a patient with significant pre-transplant antibodies with positive HLA antibody screening and SAB assay. With increased demands, the SAB assay costs would reduce further, improving its cost-effectiveness.
Funding
No funding was received to assist with the preparation of this manuscript.
Compliance with the ethical standards
Conflict of interest
The authors declare that they have no conflicts of interest.
Ethics committee approval
Approval from the institute ethics committee has been obtained. The authors declare that the clinical procedures involved were performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments.
Informed consent
Written, informed consent has been obtained from the patient.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Nwakanma LU, Williams JA, Weiss ES, Russell SD, Baumgartner WA, Conte JV. Influence of pretransplant panel-reactive antibody on outcomes in 8,160 heart transplant recipients in recent era. Ann Thorac Surg. 2007;84:1556–1562. doi: 10.1016/j.athoracsur.2007.05.095. [DOI] [PubMed] [Google Scholar]
- 2.Patel R, Terasaki PI. Significance of the positive crossmatch test in kidney transplantation. N Engl J Med. 1969;280:735–739. doi: 10.1056/NEJM196904032801401. [DOI] [PubMed] [Google Scholar]
- 3.Kobashigawa J, Colvin M, Potena L, Dragun D, Crespo-Leiro MG, Delgado JF, Olymbios M, Parameshwar J, Patel J, Reed E, Reinsmoen N, Rodriguez ER, Ross H, Starling RC, Tyan D, Urschel S, Zuckermann A. The management of antibodies in heart transplantation: an ISHLT consensus document. J Heart Lung Transplant. 2018;37:537–547. doi: 10.1016/j.healun.2018.01.1291. [DOI] [PubMed] [Google Scholar]
- 4.Costanzo MR, Dipchand A, Starling R, et al. The International Society of Heart and Lung Transplantation guidelines for the care of heart transplant recipients. J Heart Lung Transplant. 2010;29:914–956. doi: 10.1016/j.healun.2010.05.034. [DOI] [PubMed] [Google Scholar]
- 5.Clerkin KJ, See SB, Farr MA, Restaino SW, Serban G, Latif F, Li L, Colombo PC, Vlad G, Ray B, Vasilescu ER, Zorn E. Comparative assessment of anti-HLA antibodies using two commercially available Luminex-based assays. Transplantation Direct. 2017;3:e218. doi: 10.1097/TXD.0000000000000734. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Oh EJ, Park H, Park KU, Kang ES, Kim HS, Song EY. Interlaboratory comparison of the results of lifecodes LSA class I and class II single antigen kits for human leukocyte antigen antibody detection. Ann Lab Med. 2015;35:321–328. doi: 10.3343/alm.2015.35.3.321. [DOI] [PMC free article] [PubMed] [Google Scholar]
