Table 4.
Waste/By-Product | Extraction Process Parameters | Major Findings | Reference |
---|---|---|---|
Blueberry peel |
Ultrasound nominal power: 100 and 500 W Processing time: 40 min Temperature: 40 °C Solvent: Five natural deep eutectic solvents Ultrasonic equipment: Probe at 20 kHz |
|
[121] |
Blueberry pomace |
Ultrasound nominal power: 400 W Processing time: 15–35 min Temperature: 50–70 °C Solvent: Acidified hydroethanolic mixture (70% ethanol) Ultrasonic equipment: Probe |
|
[169] |
Jabuticaba by-product |
Ultrasound intensity: 1.1–13.0 W/cm² Processing time: 3 min Solvent: Hydroethanolic mixtures (0–100% ethanol) Ultrasonic equipment: Probe at 19 kHz with a diameter of 13 mm |
|
[53] |
Jabuticaba by-product |
Power density: 50 and 60 W/L Processing time: 10–40 min Solvent: Acidified water (pH 1.5, 3.0, and 7.0) Ultrasonic equipment: Ultrasound bath at 25 and 40 kHz |
|
[167] |
Black chokeberry waste |
Ultrasound nominal power: 0–100 W Processing time: 0–240 min Temperature: 20–70 °C Solvent: Hydroethanolic mixtures (0–50% ethanol) Ultrasonic equipment: Ultrasound bath at 30.8 kHz |
|
[54] |
Blackberry waste |
Ultrasound nominal power: 1500 W Processing time: 15 min Temperature: 4 °C Solvent: Water Ultrasonic equipment: Probe at 20 kHz with a diameter of 25 mm |
|
[170] |
Blackberry by-product |
Ultrasound nominal power: 580 W Processing time: 90 min Temperature: 80 °C Solvent: Hydroethanolic mixtures (50% and 70% ethanol) and acidified water (pH 2) Ultrasonic equipment: Ultrasound bath at 37 kHz |
|
[52] |
Pomegranate by-product |
Ultrasound nominal power: 70–210 W Duty cycle: 20–80% Processing time: 1–10 min Solvent: Hydroethanolic mixture (50% ethanol) Ultrasonic equipment: Probe at 20 kHz |
|
[171] |
Eggplant by-product |
Ultrasound nominal power: Not specified Processing time: 15–45 min Temperature: 25 and 50 °C Solvent: Acidified hydroethanolic mixtures (70% and 96% ethanol) Ultrasonic equipment: Ultrasound bath |
|
[41] |
Eggplant by-product |
Ultrasound nominal power: Not specified Processing time: 15–45 min Temperature: 50–70 °C Solvent: 50–90% (v/v) methanol or 2-propanol in water Ultrasonic equipment: Ultrasound bath at 12.5, 25, and 37.5 kHz |
|
[172] |
Grape pomace |
Ultrasound nominal power: 150–300 W Processing time: 2.5–10 min Temperature: 25–55 °C Solvent: Water Ultrasonic equipment: Probe at 20 kHz with a diameter of 13 mm |
|
[173] |
Raspberry by-product |
Ultrasound nominal power: 100–500 W Pectinase dosage: 0.05–0.25% Processing time: 10–50 min Temperature: 40–60 °C Solvent: Acidified hydroethanolic mixture (60% ethanol) Ultrasonic equipment: Probe |
|
[166] |
Mulberry by-product |
Ultrasound nominal power: 200–400 W Pectinase dosage: 0.15–0.25% Processing time: 60–120 min Temperature: 40–60 °C Solvent: Acidified water Ultrasonic equipment: Ultrasound bath |
|
[55] |
Peach waste |
Ultrasound nominal power: 80–400 W Processing time: 20–120 s Temperature: 25–55 °C Solvent: Hydroethanolic mixture (70% ethanol) Ultrasonic equipment: Probe at 24 kHz with a diameter of 10 mm |
|
[127] |