. 2021 Mar 16;13(3):817–824. doi: 10.1111/os.12846

Minimum 7‐year Follow‐up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty

Yong Huang 1, Yi‐xin Zhou 1,, Hua Tian 3,, Jun‐wen Wang 2, Wen‐guang Liu 4, Hu Li 5
PMCID: PMC8126901  PMID: 33728818

Abstract

Objectives

To investigate the cup survivorship, patient satisfaction level, clinical function, and radiographic outcomes of patients who underwent total hip arthroplasty (THA) using electron beam melting (EBM)‐produced porous coated titanium cups at mid‐term follow up.

Methods

A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM‐produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The inclusion criteria were: (i) patients who underwent THA with the use of EBM‐produced cups with possible 7‐year follow up; and (ii) patients with follow‐up information, including the cup survivorship, patient satisfaction level, and clinical outcomes such as Harris hip score. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7‐year follow‐up and, thus, were excluded; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. The mean age and body mass index of the patients were 59.37 (range: 38.00–69.00) years and 24.51 (range: 16.50–34.10) kg/m2, respectively. Thirteen (48.1%) of the patients were female.

Results

The average duration of follow‐up was 93.48 (range: 89.00–99.00) months. The median Harris hip score improved from 42.00 (interquartile range: 37.00–49.00) to 97.00 (interquartile range: 92.00–97.00) at the latest follow up (P < 0.001). A total of 18 (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1 (3.7%) as dissatisfied. No intraoperative or postoperative complications were identified. At the latest follow up, all cups were considered to have achieved osteointegration fixation, with three or more of the five signs evident in the most recent X‐ray. However, three cups revealed radiolucent lines with a width of less than 1 mm. The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: −3.10, 6.94) mm superiorly and 3.26 (interquartile range: −8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. Kaplan–Meier survivorship analysis of cups, with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones, reveals that the 8.25‐year survival was 96.3% (95% confidence interval: 76.49%–99.47%).

Conclusion

The mid‐term follow‐up of patients who underwent primary THA using EBM‐produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.

Keywords: 3D printing, Additive manufacturing, Electron beam melting, Primary total hip arthroplasty, Trabecular titanium cup


graphic file with name OS-13-817-g003.jpg

Electron beam melting (EBM) technology is an important branch of 3D printing technology and has been used in manufacturing trabecular titanium acetabular cups with high porosity (65%), diffuse pore interconnections, a low modulus of elasticity, high frictional resistance, and large holes (700 μm). The mid‐term follow up of patients who underwent primary THA using EBM‐produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.

Introduction

While previous studies have demonstrated cemented acetabular cups' superior initial stability when compared to press‐fit acetabular cups 1 , 2 , aseptic loosening of the cemented acetabular components results in long‐term failure of cemented primary total hip replacement as a result of their lack of secondary biologic fixation 3 , 4 . Consequently, cementless acetabular cups were developed to achieve long‐term bone ingrowth fixation and have been the gold standard for primary total hip arthroplasty (THA). Cementless acetabular cups have achieved high survivorship in primary total hip replacement as a result of resembling the properties of trabecular bone with good biocompatibility, porosity, frictional resistance, and modulus of elasticity when compared with cemented cups. The long‐term survivorship of a cementless acetabular cup in primary THA depends on rigid primary fixation and secondary fixation via bone ingrowth into the voids of the porous coated surface. Threaded acetabular shells showed rigid primary stability but demonstrated a high failure rate at medium‐term to long‐term follow up due to the lack of porous coated surface and resultant inadequate osteointegration potential 1 , 5 . Regardless of the kind of porous coated surface, the cementless acetabular components must maintain rigid initial fixation with micromotion less than 150 um, have adequate viable host bone contact, and possess an osteoconductive surface to achieve secondary biological fixation 6 , 7 .

Since their introduction in the 1970s, cementless acetabular cups have undergone various design modifications to enhance their initial stability and long‐term biological fixation. Acetabular components with two‐dimensional surfaces for bone ongrowth, including grit‐blasted surfaces and plasma‐sprayed coated surfaces, have demonstrated favorable long‐term biological fixation via bone interlocking with the inherent surface irregularities on the cup 8 . Subsequently, three‐dimensional (3D) surfaces, such as sintered titanium beads and titanium fiber mesh, which rely on the ingrowth of bone into the voids of the 3D surface, have demonstrated both positive long‐term clinical outcomes and low failure rates in primary THA 9 , 10 . Nevertheless, numerous studies have reported disadvantages of several kinds of cementless acetabular cups, including bead shedding or debonding of the porous coated surface, stress shielding, and osteolysis, which has resulted in disagreement regarding the optimal porous surface for the acetabular shells in primary THA 11 , 12 , 13 , 14 .

Porous coated tantalum acetabular cups imitating trabecular bone morphology were introduced in the 1990s and have demonstrated a superior capacity for bone ingrowth as compared to HA‐coated titanium and porous coated titanium cups, especially in revision cases 15 . A novel highly‐porous coated titanium ingrowth surface known as tritanium was introduced in 2008. This highly‐porous coated titanium ingrowth surface is manufactured by depositing commercially pure titanium into an interconnected, open‐cell, polyurethane foam with a high porosity and a high coefficient of friction. However, a recent development highly porous titanium cup has demonstrated 40% radiolucent and radiosclerotic lines in two or more DeLee zones and 17.1% in all three zones in primary THA at a minimum 5‐year follow up. These cups with radiolucent and radiosclerotic lines in two or more DeLee zones were also associated with lower Harris hip scores (HHS), raising serious concerns 16 , 17 . The fact that tritanium cups demonstrated unfavorable radiographic results in primary THA at mid‐term follow up raised severe concerns despite low revision rates 16 , 17 and indicated that new implant technology might not always bring positive results.

In last two decades, 3D printing technology has emerged and is being used increasingly frequently in the field of medicine due to several perceived advantages 18 . Compared with the traditional reduction casting process, 3D printing, or additive manufacturing, has made it easier to individualize product design and manufacturing. In this regard, 3D printing technology has continued to gain popularity and is becoming more widely used in preoperative education and training, preoperative planning, intraoperative cutting blocks and guide production, and for the fabrication of pelvic tumor endoprostheses in the orthopaedic arena, with favorable results. Electron beam melting (EBM) technology is an important branch of 3D printing technology and has been used in manufacturing trabecular titanium acetabular cups with high porosity (65%), diffuse pore interconnections, a low modulus of elasticity, high frictional resistance, and large holes (700 μm). This technology produces acetabular shells by building layers of porous scaffolds; in contrast, traditional reductive manufacturing produces acetabular cups by removing material from a raw shape and the porous coated surface is blasted or sprayed onto it. These EBM‐produced trabecular titanium cups are believed to induce vascularization and bone ingrowth into the interconnected pores and to reduce fibrotic peri‐acetabular tissue; these cups have demonstrated positive clinical and radiographic outcomes at midterm follow‐up 19 , 20 , 21 .

However, to our best knowledge, only a small number of studies exist that report the positive results of EBM‐produced trabecular titanium cups in primary THA with short‐term to mid‐term follow‐up 19 , 20 , 21 , 22 , 23 . This study aims to investigate: (i) the cup survivorship; (ii) the patient satisfaction level and clinical function; and (iii) the radiographic outcomes of patients who underwent primary THA using EBM‐produced trabecular titanium cups with mid‐term follow‐up.

Materials and Methods

Patients Selection

A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM‐produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The 32 patients consisted of 10 patients from one hospital, 6 patients each from another two hospitals, and 5 patients each from the remaining two hospitals. The inclusion criteria were: (i) patients who underwent THA with the use of EBM‐produced cups with possible 7‐year follow up; (ii) patients with follow‐up information including the cup survivorship, patient satisfaction level, and clinical outcomes such as the HHS. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7‐year follow up and, thus, were excluded from the study; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. Of the 27 enrolled patients, 23 had X‐rays with minimum 5‐year follow up. The average duration of follow‐up was 93.48 (range: 89.00–99.00) months. The mean age and the body mass index of the patients were 59.37 (range: 38.00–69.00) years and 24.51 (range: 16.50–34.10) kg/m2, respectively. Among the patients, 13 (48.1%) were female. The original diagnosis of the 27 patients included avascular necrosis in 9 (33.3%) patients, primary osteoarthritis in 11 (40.7%) patients, developmental dysplasia of the hip (DDH) in 3 (11.1%) patients, rheumatoid arthritis in 2 (7.4%) patients, and acute femoral neck fracture in 2 (7.4%) patients. The present study was commenced after approval from the institutional review board of our institution. Informed consent was obtained from all patients.

Implants

The acetabular cup (3D ACT cup, AK Medical, Beijing, China; Fig. 1A) used in the present study was manufactured with the EBM technique 24 , 25 . The 3D structure of the scaffold was designed using computer‐assisted design (CAD) software (Magics), and the data were stored in STL file format. The porous architecture was designed based on a dodecahedron unit cell (Fig. 1B). The cups were then prototyped using the EBM Q10 system (Acram AB, Sweden). This technique allows the melting of thin layers of metal powder, modeling a bulk construct which respects the original metal alloy properties and integrates a fine trabecular surface. This one‐step fabrication process allows structural continuity between the solid substrate part and the porous surface; thus, the EBM‐produced trabecular titanium cups possess the advantages of greater structural solidity, no risk of shedding of the coating, and a higher resistance to detachment and corrosion compared with the relative high risk of shedding with the conventional manufacturing process due to its binding interface between the porous surface and the substrate material.

Fig. 1.

Fig. 1

Electron beam melting (EBM)‐produced trabecular titanium acetabular cup (A) and scanning electron microscope image of the cup demonstrating interconnected trabecular titanium cellular solid structure (B).

The 3D ACT cups were characterized by a porosity of 50% to 80%, pore size of 600–800 μm, coefficient of friction on cancellous bone of 1.00–1.08, and modulus of elasticity of 0.5–1.3 GPa, on average. All of the pores were 100% interconnected. The diameter of the 3D ACT cup system ranges from 40 to 70 mm, with 2‐mm increments. The average cup diameter in the present study was 48.96 (range: 44–52) mm. All of the coupled bearing surfaces were ceramic on highly cross‐linked polyethylene. All of the femoral heads were BIOLOX Delta ceramic (CeramTec GmbH, Plochingen, Germany). The diameters of 24 femoral heads were 28 mm, while the other 3 head diameters were 22 mm.

Surgery Process

All of the procedures were performed with general anesthesia or combined spinal epidural at the discretion of the anesthesiologist through a posterolateral surgical approach with the patient in the lateral decubitus position. We incised the tensor fasciae latae and split the gluteus maximus in the direction of the muscle fibers. The short extortors were cut off from the proximal femur and the hip capsular were incised. After dislocation of the femora head, the labrum, ligamentum capitis femoris, and other fat or fibrous tissue were resected, and the acetabulum was reamed until fresh bleeding bone was reached. The cups were inserted by five different consultant surgeons from five different hospitals, with 1 mm of under‐reaming to achieve a 1‐mm press fit according to the manufacturers' recommendations Additional screw fixation was used based on each surgeon's preference.

Clinical Outcome Measures

Each patient's clinical and radiographic data were prospectively documented by the clinical staff at the time of the index procedure at each center. Patients were asked to return to the clinic for follow up at 1, 3, 6, and 12 months postoperatively and annually thereafter. The attending surgeon assessed the clinical results using the HHS 26 . All patients underwent standard anteroposterior radiographs of the bilateral hips at each follow‐up visit. Patients who were unable to return to visit the hospital postoperatively were followed up by telephone and mailed us their latest radiographs for review. Patients were asked to rate their satisfaction level of the clinical outcome on the basis of an arbitrary scale including five levels of satisfaction: very dissatisfied, dissatisfied, neutral, satisfied, or very satisfied 27 .

Harris Hip Score

The HHS was used to assess the hip function in an adult population. The HHS mainly consists of four domains: pain, function, deformity, and range of motion. The maximum score is 100 points, which indicates the best hip function. A total score less than 70 is deemed poor, 70–80 as fair, 80–90 as good, and 90–100 as excellent.

Radiographic outcome measures

Two independent surgeons who did not participate in the procedure and were blinded to the clinical outcomes evaluated the radiographic outcomes of the cup, including the presence of radiolucent lines in the DeLee‐Charnley zones, by reviewing all the postoperative serial radiographs. Any discrepancies between the two reviewers were discussed and the final decision was made by a third consultant senior surgeon. All of the radiographic variations in magnification were calibrated with the known head size as an internal reference.

Cup Loosening and Osteointegration

Cup loosening was defined as the acetabular shell migrating by more than 3 mm and/or a change in inclination by more than 5° in comparison with the immediate postoperative radiographs, as well as being bordered by a progressive radiolucent line wider than 2 mm 28 , 29 . Cup osteointegration was assessed according to the criteria of Moore et al. 30 , which includes the absence of a radiolucent line(s), superolateral buttress, medial stress shielding, radial trabeculae, and inferomedial buttress. A cup was considered to have osteointegrated when three or more of the five signs were visualizable on the postoperative radiographs. Cup loosening and osteointegration indicate the fixation status of the cup. Cup loosening means the cup fails and cup osteointegration means the cup achieves bone ingrowth fixation.

Cup Inclination and Anteversion Angle

The cup inclination angle was measured with reference to the inter‐teardrop line and the anteversion angle was measured in accordance with the method of Lewinnek 31 et al., both on the latest anteroposterior plain radiograph. The cup inclination and anteversion angle represent the orientation of the cup, and having a satisfactory cup inclination and anteversion angle minimizes the risk of postoperative hip dislocation.

Vertical and Horizontal Position of the Center of Rotation

The vertical and horizontal positions of the center of rotation refer to the vertical and horizontal distances of the center of rotation to the anatomic center of the femoral head. The vertical and horizontal distances of the center of rotation to the anatomic center of the femoral head were measured on the preoperative and postoperative radiographs. A proper vertical and horizontal position of the center of rotation improves the postoperative hip biomechanics and function and increases the long‐term cup survivorship.

Statistical Analysis

The normality of the continuous variables was examined using the Shapiro–Wilk test. Continuous data were compared using the Wilcoxon signed rank test and summarized as the median and interquartile range. Categorical data were summarized as numbers and percentages. Kaplan–Meier cup survival analysis was performed using Stata 12.0 software (Stata, College Station, TX, USA), with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones. The significance level was set at P < 0.05. All statistical analyses were conducted using SPSS 17.0 for Windows (IBM, Armonk, NY, USA).

Results

Clinical Outcome Measures

The median HHS score improved from 42.00 (interquartile range: 37.00–49.00) to 97.00 (interquartile range: 92.00–97.00) at the latest follow up (P < 0.001). Eighteen (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral, and 1 (3.7%) as dissatisfied. No patient rated themselves as very dissatisfied. The dissatisfied patient was diagnosed with rheumatoid arthritis, which had damaged multiple joints, especially the knee and ankle joints. As such, this patient had difficulty with ambulating due to hip, knee, and ankle joint pain.

Radiographic Outcome Measures

At the latest follow‐up, all cups were considered to have achieved fixation via bone ingrowth, with three or more of the five signs identifiable on the latest radiographs (Figs 2, 3, 4). However, three cups revealed radiolucent lines of less than 1 mm in width. These radiolucent lines were distributed in DeLee–Charnley zone 1 in one patient, zone 3 in another patient, and zones 1 and 2 in the third patient.

Fig. 2.

Fig. 2

(A) The preoperative anteroposterior view of the bilateral hip joint of a 60‐year old man diagnosed as developmental dysplasia of the hip. (B) The immediate postoperative and (C) the 90‐month postoperative anteroposterior view of the bilateral hip joint demonstrating favorable bone ingrowth fixation.

Fig. 3.

Fig. 3

(A) The preoperative anteroposterior view of the right hip joint of a 63‐year old woman diagnosed as right femoral head necrosis. (B) The immediate postoperative, (C) the 3‐month postoperative anteroposterior view, and (D) the 60‐month postoperative anteroposterior view (D) of the right hip joint demonstrating favorable bone ingrowth fixation.

Fig. 4.

Fig. 4

(A) The preoperative anteroposterior view of the right hip joint of a 64‐year old man diagnosed as right femoral neck fracture. (B) The immediate postoperative, (C) the 3‐month postoperative anteroposterior view, and (D) the 63‐month postoperative anteroposterior view (D) of the right hip joint demonstrating favorable bone ingrowth fixation.

The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: −3.10, 6.94) mm superiorly and 3.26 (interquartile range: −8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. The mean acetabular cup abduction and anteversion angles were 40.91° (interquartile range: 36.25°, 45.09°) and 16.56° (interquartile range: 13.22°, 19.84°) at the most recent postoperative follow‐up.

Survivorship Analysis

Kaplan–Meier survivorship analysis of cups with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones reveals that the 8.25‐year survival was 96.3% (95% confidence interval: 76.49%–99.47%, Fig. 5).

Fig. 5.

Fig. 5

Kaplan–Meier survivorship analysis of cups with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones. CI, confidence interval.

Complications

No intraoperative or postoperative complications were identified, including aseptic cup loosening, hip dislocation, periprosthetic joint infection, periprosthetic fracture, nerve palsy, hematoma, or incisional dehiscence.

Discussion

Cementless acetabular cups with various surface coating modifications have demonstrated adequate biological fixation. Among these, the trabecular metal porous tatanlum surface appears noteworthy. Apart from cup surface coating modifications, the additive manufacturing techniques, specifically the EBM technique, have also been introduced in last two decades to produce trabecular titanium acetabular cups. Nevertheless, few studies have reported positive clinical and radiographic outcomes at short‐term to mid‐term follow up 19 , 20 , 21 , 22 , 23 .

Clinical Outcome and Survivorship

Perticarini et al. 19 first reported encouraging clinical and radiographic performance of the EBM‐produced trabecular titanium cups at an average follow up of 72.7 months. Castagnini 21 et al. also demonstrated reliable clinical and radiographic results for trabecular titanium cups produced using the EBM technique. In another registry study 20 enrolling 36,787 cementless cups, Castagnini et al. reported that EBM‐produced trabecular titanium cups (9864 patients) achieved significantly higher survival rates (98.7% vs 97.9%) than other cementless sockets (26,923 patients) at 7‐year follow‐up. All of the patients using the EBM‐produced trabecular titanium cups in the present study also achieved good clinical function and satisfaction levels at mid‐term follow‐up, indicating considerable improvement in pain relief, functional recovery, and quality of life. The results were consistent with and further confirmed previous findings with regards to the EBM‐produced trabecular titanium cups 19 , 20 , 21 , 22 , 23 .

The encouraging clinical outcomes and survivorship rates of the EBM‐produced trabecular titanium cups in the current study rely on the solid initial fixation and excellent osteointegration capacity. The rigid primary stability of the cup may contribute to its relatively larger coefficient of friction and low modulus of elasticity. Previous studies have demonstrated that the stability of the acetabular components is markedly influenced by the coefficient of friction 32 . Increasing the coefficient of friction may reduce interface micromotion, enhance primary fixation, and contribute to secondary fixation via bone ingrowth given that micromotion beyond 150 μm is known to induce a pattern of fibrous tissue ingrowth pattern at the bone–implant interface 6 . The coefficient of friction of the EBM‐produced trabecular titanium material on cancellous bone is 1.00–1.08, higher than that of trabecular metal porous tantalum on cancellous (0.98) and sintered beads on cancellous bone (0.5). The microspikes on the surface of EBM‐produced trabecular titanium cups may also facilitate its initial fixation 21 . The modulus of elasticity of the EBM‐produced trabecular titanium is 0.5–1.3 GPa, on average, which is lower than that of tantalum trabecular metal material (3 GPa). Furthermore, a low modulus of elasticity facilitates physiological stress transfer, which helps reduce the risk of stress shielding and bone resorption, as Massari 23 et al. indicated in their study using the method of dual energy X‐ray absorptiometry (DEXA).

Radiographic Outcome Measures

The fact that all the EBM‐produced highly porous trabecular titanium cups demonstrated three or more of the five signs that Moore et al. 30 have proposed reflects excellent osteointergration capacity. The EBM‐produced trabecular titanium cups have a porosity of 80%, a pore size of 600–800 μm, and 100% interconnected pores. High porosity has been demonstrated to improve local vascularization, to decrease peri‐implant fibrotic tissue, and to stimulate favorable bone ingrowth 33 , 34 . Although Taniguchi et al. 35 demonstrated that the EBM‐produced pore size promotes deep bone ingrowth in an in vivo study, such a pore size cannot be achieved with traditional manufacturing processes. Furthermore, multiple previous studies have revealed that EBM‐produced trabecular titanium possesses good mechanical, osteoconductive, and osteoinductive properties, particularly in regard to the ability to promote osteoblast proliferation and differentiation 36 , 37 .

Massari et al. 23 observed no radiolucent lines in a 2‐year follow‐up of 91 EBM‐produced highly porous trabecular titanium cups. Perticarini et al. 19 also reported no radiolucent lines around 134 EBM‐produced trabecular titanium cups at an average follow up of 72.7 months. Castagnini 21 et al. reported no radiolucencies around 24 EBM‐produced trabecular titanium cups at a mean follow up of 79 months. Our study found radiolucent lines with a width of less than 1 mm in 3 patients, which is comparable to the results of the above studies. However, Imai et al. 22 observed radiolucent lines in two zones in 13 DDH hips and in three zones in 2 DDH hips in a study of 101 EBM‐produced highly porous titanium cups with a mean follow‐up of 1.6 years. The authors speculated that there might be micromotion between the cups using clustered screws and the acetabular bone in cases of DDH with atrophic bone remodeling patterns. This difference may be due to the fact that patients with DDH had inadequate bone stock for cup initial fixation. Thus, Imai et al. 22 suggest using multiple screws to enhance initial fixation of EBM‐produced trabecular titanium cups in such patients.

The present study has several limitations. First, this study is a case series with a small number of patients without a comparative group. Second, the patients in this study were enrolled from five different hospitals and were operated on by five different surgeons, which may confound the results; however, all cups were inserted in accordance with the manufacturer's production manual by consultant surgeons with at least 50 cases per year. Third, a radiostereometric and DEXA‐based peri‐acetabular bone quality and density evaluation was not performed on patients in the current study. Fourth, serum ion concentration measurements were not conducted to evaluate the corrosion safety of EBM‐produced cups.

Conclusion

In summary, the mid‐term follow‐up of patients who underwent primary THA with the use of EBM‐produced porous coated titanium cups demonstrated favorable patient satisfaction levels, good clinical function, excellent survivorship, and adequate biological fixation. However, as with all new implant technology, this should be used in a stepwise process. The outcomes of the EBM‐produced trabecular titanium cups remain to be investigated in a larger volume of patients and at longer‐term follow‐up.

Disclosure: The authors have no commercial associations (e.g. consultancies, stock ownership, equity interest, and patent/licensing arrangements) that might pose a conflict of interest in connection with the submitted article. The institution of two of the authors (YH, YZ) has received funding from Beijing Municipal Science and Technology Planning Project (code: Z181100001618005 and Z191100007619046), the National Natural Science Foundation of China (code: 82072457), Beijing Jishuitan Hospital horizontal project (the clinical study of custom bone and joint prosthesis) and Beijing Jishuitan Hospital Natural Fund Incubation Program (code: ZR‐201917).

Contributor Information

Yi‐xin Zhou, Email: orthoyixin@yahoo.com.

Hua Tian, Email: tianhua@bjmu.edu.cn.

References

  • 1. Litsky AS, Pophal SG. Initial mechanical stability of acetabular prostheses. Orthopedics, 1994, 17: 53–57. [DOI] [PubMed] [Google Scholar]
  • 2. Perona PG, Lawrence J, Paprosky WG, Patwardhan AG, Sartori M. Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty. An in vitro comparison of different methods of initial acetabular component fixation. J Arthroplasty, 1992, 7: 537–547. [DOI] [PubMed] [Google Scholar]
  • 3. Callaghan JJ, Albright JC, Goetz DD, Olejniczak JP, Johnston RC. Charnley total hip arthroplasty with cement. Minimum twenty‐five‐year follow‐up. J Bone Joint Surg Am, 2000, 82: 487–497. [DOI] [PubMed] [Google Scholar]
  • 4. García‐Cimbrelo E, Munuera L. Early and late loosening of the acetabular cup after low‐friction arthroplasty. J Bone Joint Surg Am, 1992, 74: 1119–1129. [PubMed] [Google Scholar]
  • 5. Clarius M, Jung AW, Streit MR, Merle C, Raiss P, Aldinger PR. Long‐term results of the threaded Mecron cup in primary total hip arthroplasty: a 15–20‐year follow‐up study. Int Orthop, 2010, 34: 1093–1098. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous‐surfaced implants. Clin Orthop Relat Res, 1986, 208: 108–113. [PubMed] [Google Scholar]
  • 7. Adler E, Stuchin SA, Kummer FJ. Stability of press‐fit acetabular cups. J Arthroplasty, 1992, 7: 295–301. [DOI] [PubMed] [Google Scholar]
  • 8. Illgen R II, Rubash HE. The optimal fixation of the cementless acetabular component in primary total hip arthroplasty. J Am Acad Orthop Surg, 2002, 10: 43–56. [DOI] [PubMed] [Google Scholar]
  • 9. McLaughlin JR, Lee KR. Cementless total hip replacement using second‐generation components: a 12‐ to 16‐year follow‐up. J Bone Joint Surg Br, 2010, 92: 1636–1641. [DOI] [PubMed] [Google Scholar]
  • 10. Munzinger U, Guggi T, Kaptein B, Persoon M, Valstar E, Doets HC. A titanium plasma‐sprayed cup with and without hydroxyapatite‐coating: a randomised radiostereometric study of stability and osseointegration. Hip Int, 2013, 23: 33–39. [DOI] [PubMed] [Google Scholar]
  • 11. von Knoch M, Sychterz CJ, Engh CA Jr, Engh CA Sr. Incidence of late bead shedding from uncemented porous coated cups. A radiographic evaluation. Clin Orthop Relat Res, 1997, 342: 99–105. [PubMed] [Google Scholar]
  • 12. Jasty M, Bragdon C, Jiranek W, Chandler H, Maloney W, Harris WH. Etiology of osteolysis around porous‐coated cementless total hip arthroplasties. Clin Orthop Relat Res, 1994, 308: 111–126. [PubMed] [Google Scholar]
  • 13. Kleinhans JA, Jakubowitz E, Seeger JB, Heisel C, Kretzer JP. Macroscopic third‐body wear caused by porous metal surface fragments in total hip arthroplasty. Orthopedics, 2009, 32: 364–366. [DOI] [PubMed] [Google Scholar]
  • 14. Galante JO, Jacobs J. Clinical performances of ingrowth surfaces. Clin Orthop Relat Res, 1992, 276: 41–49. [PubMed] [Google Scholar]
  • 15. Jafari SM, Bender B, Coyle C, Parvizi J, Sharkey PF, Hozack WJ. Do tantalum and titanium cups show similar results in revision hip arthroplasty? Clin Orthop Relat Res, 2010, 468: 459–465. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Carli AV, Warth LC, de Mesy Bentley KL, Nestor BJ. Short to midterm follow‐up of the Tritanium primary acetabular component: a cause for concern. J Arthroplasty, 2017, 32: 463–469. [DOI] [PubMed] [Google Scholar]
  • 17. Long WJ, Nayyar S, Chen KK, Novikov D, Davidovitch RI, Vigdorchik JM. Early aseptic loosening of the Tritanium primary acetabular component with screw fixation. Arthroplasty Today, 2018, 4: 169–174. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Langridge B, Momin S, Coumbe B, Woin E, Griffin M, Butler P. Systematic review of the use of 3‐dimensional printing in surgical teaching and assessment. J Surg Educ, 2018, 75: 209–221. [DOI] [PubMed] [Google Scholar]
  • 19. Perticarini L, Zanon G, Rossi SM, Benazzo FM. Clinical and radiographic outcomes of a trabecular titanium acetabular component in hip arthroplasty: results at minimum 5 years follow‐up. BMC Musculoskelet Disord, 2015, 16: 375. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Castagnini F, Bordini B, Stea S, Calderoni PP, Masetti C, Busanelli L. Highly porous titanium cup in cementless total hip arthroplasty: registry results at eight years. Int Orthop, 2019, 43: 1815–1821. [DOI] [PubMed] [Google Scholar]
  • 21. Castagnini F, Bordini B, Yorifuji M, et al. Highly porous titanium cups versus hydroxyapatite‐coated sockets: mid‐term results in Metachronous bilateral Total hip arthroplasty. Med Princ Pract, 2019, 28: 559–565. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Imai H, Miyawaki J, Kamada T, et al. Radiolucency around highly porous sockets and hydroxyapatite‐coated porous sockets in total hip arthroplasty for hip dysplasia. Eur J Orthop Surg Traumatol, 2019, 29: 611–618. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Massari L, Bistolfi A, Grillo PP, et al. Periacetabular bone densitometry after total hip arthroplasty with highly porous titanium cups: a 2‐year follow‐up prospective study. Hip Int, 2017, 27: 551–557. [DOI] [PubMed] [Google Scholar]
  • 24. Marin E, Fusi S, Pressacco M, Paussa L, Fedrizzi L. Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: trabecular titanium. J Mech Behav Biomed Mater, 2010, 3: 373–381. [DOI] [PubMed] [Google Scholar]
  • 25. Marin E, Pressacco M, Fusi S, Lanzutti A, Turchet S, Fedrizzi L. Characterization of grade 2 commercially pure trabecular titanium structures. Korean J Couns Psychother, 2013, 33: 2648–2656. [DOI] [PubMed] [Google Scholar]
  • 26. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end‐result study using a new method of result evaluation. J Bone Joint Surg Am, 1969, 51: 737–755. [PubMed] [Google Scholar]
  • 27. Tang H, Du H, Tang Q, Yang D, Shao H, Zhou Y. Chinese patients' satisfaction with total hip arthroplasty: what is important and dissatisfactory? J Arthroplasty, 2014, 29: 2245–2250. [DOI] [PubMed] [Google Scholar]
  • 28. Callaghan JJ, Dysart SH, Savory CG. The uncemented porous‐coated anatomic total hip prosthesis. Two‐year results of a prospective consecutive series. J Bone Joint Surg Am, 1988, 70: 337–346. [PubMed] [Google Scholar]
  • 29. Wegrzyn J, Kaufman KR, Hanssen AD, Lewallen DG. Performance of porous tantalum vs. titanium cup in total hip arthroplasty: randomized trial with minimum 10‐year follow‐up. J Arthroplasty, 2015, 30: 1008–1013. [DOI] [PubMed] [Google Scholar]
  • 30. Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous‐coated acetabular components. Clin Orthop Relat Res, 2006, 444: 176–183. [DOI] [PubMed] [Google Scholar]
  • 31. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip‐replacement arthroplasties. J Bone Joint Surg Am, 1978, 60: 217–220. [PubMed] [Google Scholar]
  • 32. Saleh KJ, Bear B, Bostrom M, Wright T, Sculco TP. Initial stability of press‐fit acetabular components: an in vitro biomechanical study. Am J Orthop (Belle Mead NJ), 2008, 37: 519–522. [PubMed] [Google Scholar]
  • 33. Ponader S, von Wilmowsky C, Widenmayer M, et al. In vivo performance of selective electron beam‐melted Ti‐6Al‐4V structures. J Biomed Mater Res A, 2010, 92: 56–62. [DOI] [PubMed] [Google Scholar]
  • 34. Otsuki B, Takemoto M, Fujibayashi S, Neo M, Kokubo T, Nakamura T. Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three‐dimensional micro‐CT based structural analyses of porous bioactive titanium implants. Biomaterials, 2006, 27: 5892–5900. [DOI] [PubMed] [Google Scholar]
  • 35. Taniguchi N, Fujibayashi S, Takemoto M, et al. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment. Korean J Couns Psychother, 2016, 59: 690–701. [DOI] [PubMed] [Google Scholar]
  • 36. Asti A, Gastaldi G, Dorati R, et al. Stem cells grown in osteogenic medium on PLGA, PLGA/HA, and titanium scaffolds for surgical applications. Bioinorg Chem Appl, 2010: 831031. 10.1155/2010/831031. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Gastaldi G, Asti A, Scaffino MF, et al. Human adipose‐derived stem cells (hASCs) proliferate and differentiate in osteoblast‐like cells on trabecular titanium scaffolds. J Biomed Mater Res A, 2010, 94: 790–799. [DOI] [PubMed] [Google Scholar]

Articles from Orthopaedic Surgery are provided here courtesy of Wiley