Skip to main content
Oxford University Press - PMC COVID-19 Collection logoLink to Oxford University Press - PMC COVID-19 Collection
. 2021 Apr 29:ciab330. doi: 10.1093/cid/ciab330

SARS-CoV-2 detection on self-collected saliva or anterior nasal specimens compared with healthcare personnel-collected nasopharyngeal specimens

Grace E Marx 1,2,3,, Brad J Biggerstaff 1, Courtney C Nawrocki 1,4, Sarah E Totten 5, Emily A Travanty 5, Alexis W Burakoff 5, Tracy Scott 2, Jesse Chavez-Van De Hey 2, Jesse J Carlson 2, Karen A Wendel 2,3, Jennifer L Harcourt 6, Azaibi Tamin 6, Jennifer D Thomas 6, Sarah E Rowan 2,3; CDPHE COVID-19 Laboratory Response Team5; CDC COVID-19 Laboratory Response Team6
PMCID: PMC8135412  PMID: 33912930

Abstract

Background

Nasopharyngeal specimens (NPS) are commonly used for SARS-CoV-2 testing but can be uncomfortable for patients. Self-collected saliva or anterior nasal specimens (ANS) for SARS-CoV-2 detection are less invasive but the sensitivity of these specimen types has not been thoroughly evaluated.

Methods

During September–November 2020, 730 adults undergoing SARS-CoV-2 testing at community testing events and homeless shelters in Denver provided self-collected saliva and ANS specimens before NPS collection and answered a short survey about symptoms and specimen preference. Specimens were tested for SARS-CoV-2 by rRT-PCR; viral culture was performed on a subset of specimens positive by rRT-PCR. Sensitivity of saliva and ANS for SARS-CoV-2 detection by rRT-PCR was measured against NPS. Subgroup analyses included test outcomes by symptom status and culture results.

Results

Sensitivity for SARS-CoV-2 detection by rRT-PCR appeared higher for saliva than for ANS (85% vs. 80%) and among symptomatic participants than among those without symptoms (94% vs. 29% for saliva; 87% vs. 50% for ANS). Among participants with culture-positive SARS-CoV-2 by any specimen type, sensitivity of saliva and ANS by rRT-PCR was 94% and 100%, respectively. Saliva and ANS were equally preferred by participants; most would undergo NPS again despite being least preferred.

Conclusions

Saliva was slightly more sensitive than ANS for SARS-CoV-2 detection by rRT-PCR. Both saliva and ANS reliably detected SARS-CoV-2 among participants with symptoms. Self-collected saliva and ANS offer practical advantages, are preferred by patients, and might be most useful for testing people with COVID-19 symptoms.

Keywords: SARS-CoV-2, COVID-19, nasopharyngeal, anterior nasal, saliva


Articles from Clinical Infectious Diseases: An Official Publication of the Infectious Diseases Society of America are provided here courtesy of Oxford University Press

RESOURCES