Assessment of economic, thermal and hydraulic performances a corrugated helical heat exchanger filled with non-Newtonian nanofluid

Muhammad Ibrahim 1, Ebrahem A Algehyne 2, Tareq Saeed 3, Abdallah S Berrouk 4,5, Yu-Ming Chu 6,7,, Goshtasp Cheraghian 8,
PMCID: PMC8172921  PMID: 34078974

Abstract

Improved heat transfer efficiency with considering economic analysis in heating systems is an interesting topic for researchers and scientists in recent years. This research investigates the heat transfer rate (HTR) and flow of non-Newtonian water-Carboxyl methyl cellulose (CMC) based Al2O3 nanofluid in a helical heat exchanger equipped with common and novel turbulators using two-phase model. The requirements for dimensions and cost reduction and also energy saving in thermal systems are the main goal of this study. According to gained results usage of corrugated channel in helical heat exchanger has a considerable influence on thermal and hydraulic performance evaluation criteria (THPEC) index of helical heat exchanger and can improve the THPEC index. Thus, Re = 5000 is obtained as an optimum value, in which the maximum THPEC value is achieved. As it is found in this paper, in case of using novel heat exchanger instead of the basic smooth system, the thermal properties (by considering Nusselt number) increases about 210%, the hydraulic performance (friction factor) reduces about 28%, performance evaluation criteria index increases about 57% and the material consumption (in case of similar THPEC) decreases about 31%. In another word, with considering economic analysis for the basic and novel system which has same efficiencies, the novel one has lower length and consequently 31% lower material.

Subject terms: Mechanical engineering, Energy infrastructure

Introduction

Various experimental, analytical and numerical investigations are published due to intensifying the heat transferred amount in heat exchangers. The key aim of these researches is improvement in the heat transfer coefficient (HTC) with the minimum pressure drop. Recent study has been concentrated on the two effective techniques for HTR increment used in the heat exchangers. Vortex generators have been used recently as a typical example of HTR enhancement technique to increase the overall HTC from the fluid or nanofluid flow surface through an upsurge in turbulent motion because of the strong turbulence intensity increase. Nanofluids, which are new type of heat transfer fluids (HTRs), have been used recently also in the heat exchangers as an excellent HTR enhancement technique due to its thermal and physical properties1,2.

Due to the crucial applications of corrugated thermal systems in the apparatus such as heat exchangers, the topic is considered by many researchers127. Arie et al.1 performed an investigation on a manufactured innovative polymer-composite heat exchanger for applications in dry cooling field. Their work pays attention on the thermal characterization and also design of an innovative heat exchanger manufactured by a new process. Their study especially establishes the increasable manufacturing influence in understanding potentially transformative heat exchanger technologies which can also be very problematic for achieving conventional-fabrication methods. Bezaatpour and Rostamzadeh2 in a numerical study observed HTR improvement of a fin and tube compact heat exchanger which is under magnetite filed and is filled with ferro-nano-fluid flow. In their study, the influence of a uniform exterior magnetic field on HTR of a heat exchanger filled with Fe3O4/water nanofluid was numerically studied. Abeykoon et al.3 designed compact heat exchangers numerically. Numerical and analytical data presented only a 1.05% change in the cooling performance of the hot fluid characteristic. The axial pressure reductions displayed positive correlations with both the pumping power request and the overall HTC. Their achieved results validate that numerical simulation can be talented for optimization, design and manufacturing of thermal systems.

Saleh et al.4 carried out a numerical study on wire finned heat exchanger using aluminum fumarate for adsorption heat pumps. They investigated the performance of a wire finned and finned microchannel heat exchangers numerically and experimentally. Their numerical method was confirmed using empirical data and represented an excellent agreement between numerical and experimental results. Hagen et al.5 investigated a new method to analysis the Rankine cycle using the generic heat exchanger models. Their findings displayed that employing the innovative analysis resulted in lower net power than using the thermodynamic analyses and this behavior is because of working fluid depending pressure reduction penalty in thermal systems. Larwa and Kupiec6 considered a horizontal heat exchanger using an analytical method for the heat transfer process. They realized that variations in ground averaged yearly temperature concerns just the subsurface layers in the initial period of exchanging operation.

Naicker and Rees7 studied a large borehole heat exchanger array. The main goal in their study was to introduce a reference data set for analysis of large borehole thermal systems and verification of numerical methods. Warner et al.8 studied a novel shallow bore ground heat exchanger. Hu et al.9 studied numerically and experimentally investigated a PCM solar air heater and its preheating efficiency. This system was designed to improve indoor air quality and thermal comfort conditions. They employed solar energy as a permanent pre-heated air source and reported their results numerically and experimentally. A numerical investigation on the thermal performance enhancement of ground air heaters using sand-bentonite as backfilling material was done by Agrawal et al.10. Their study also exposed that the factor of thermal performance deterioration surges with the operation duration. Maximum thermal performance deterioration factor is obtained for ground-air heat exchanger with dry soil at airflow velocity of 5 m/s after 6 h of continuous operation. Minimum thermal performance deterioration factor is observed for ground-air heat exchanger system with wet sand-bentonite. Wen et al.11 observed that the amplitude upsurge and wavelength reduction result in heat transfer area and larger flow length of the corrugated channel, as well as higher HTR. The corrugated channel improves HTR compared to smooth channel. A numerical investigation on airside characteristics of sinusoidal corrugated heat exchangers subject to large-diameter tubes with round or oval cross-section tubes were invetigated by Chu et al.12. The CFD technique has also been adopted to examine complete local heat transfer presentation. Moreover, Yu et al.13 used longitudinal turbulators in a new compound parallel flow shell-and-tube heat exchanger to evaluate turbulent heat transfer. Experimental, analytical, mathematical and numerical investigations showed that the baseline geometry results in the best thermal performance. The increase of the LVG height and LVG attack angle may enhance the THPEC.

Employing horizontal flat-panel ground heat exchangers in ground-coupled heat-pumps was investigated by Habibi et al.14 numerically. Their achieved data present that even though growing buried depth leads to intensification in the thermal characteristic, the improvement rate reduces sharply when the ground heat exchanger is more than ten meter wide. Kerme and Fung15 studied in a numerical study heat transfer simulation, examination and presentation study of a single U-tube borehole heat exchanger. Their obtained results may significantly decrease the devoted time for investigation and to more rapid determination the impact of different parameters on vertical single U-tube borehole heat exchanger performance. Additionally, their achieved data can be used as a reference for cooling and heating system optimization and design integrated with system of ground coupled heat pump.

Keshavarz Moraveji et al.28 examined the heat transfer distribution of non-Newtonian nanofluids (NNNFs) in a horizontal-smooth tube under the steady state heat flux, numerically. The studied NNNF included an aqueous solution based Al2O3 with various nanoparticles sizes. Their achieved data indicates that the nanofluid HTC and predicted mean Nusselt numbers upsurge in the most non-Newtonian base fluid viscosity values. Akbari et al.29 studies numerically fluid flow and heat transfer distribution of a NNNF through a two-dimensional channel with rectangular cross-section. Their achieved data demonstrated that solid particles adding with various diameters to the base fluid upsurges the HTR in studied microchannel. Minea30 analyzed the turbulent flow and heat transfer distribution of water based Al2O3 nanofluid with various volume fractions of nanoparticles in a tube with micro-size. Their results showed that the enhancement of nanofluid HTC is remarkable and has been raised significantly by increasing the nanoparticles volume fraction. Zeinali Heris et al.31 studied during a numerical investigation fluid flow and heat transfer distribution of nanofluid flow in a circular pipe. They found that the solid particles may lead to an enhancement in the HTR. In recent years, interesting and diverse studies have been conducted in these fields3241.

It should be noted that in most aforementioned investigation, the impact of different ribs and corrugations on hydraulic and thermal behavior of base fluid or nanofluids flowing in ducts has been investigated employing single phase model42,43. However, the literature review shows that the effect of novel turbulators (with minimum pressure drop error) on the hydraulic and thermal performance of two-phase NNNF has rarely been described.

Thus, the novelties of this article are as follows:

  • Description of the thermal and hydraulic behavior of nanofluids flowing in a heat exchanger with novel turbulators using ANSYS FLUENT 1844 software.

  • Evaluation of the impacts of using dissimilar types of turbulators on thermal–hydraulic characteristics.

  • Investigating the impacts of different values of φ and various nanoparticle diameters on thermal and hydraulic behavior.

  • In the simulation, two-phase modelling for nanofluid is used.

Numerical model

Physical model

The schematic of studied smooth helical heat exchanger has been presented in Fig. 1. Moreover, Figs. 2 and 3 show the schematic diagram of studied helical heat exchanger equipped with corrugations. In addition, the geometrical properties and configuration of turbulators are presented in this figure. The dimensional properties of the studied heat exchanger have been reported in Figs. 1, 2 and 3. The geometrical dimensions of the heat exchanger are the same for all considered configurations. In other words, the length and diameter of helical channel are similar for all studied models. Due to simplify the simulation procedure bellow assumptions have been considered39:

  • The temperatures of walls are maintained at 400 K.

  • There is no leakage between the different connections.

  • The heat flux of the shell is ignored.

  • The nanofluid properties are a function of temperature, volume fraction and particle sizes.

  • Differences in hydric diameter are negligible.

Figure 1.

Figure 1

Schematic of studied smooth helical heat exchanger (Images used courtesy of ANSYS, Inc.).

Figure 2.

Figure 2

Schematic of studied helical heat exchanger with common turbulators (Images used courtesy of ANSYS, Inc.).

Figure 3.

Figure 3

Schematic diagram of studied helical heat exchanger with different turbulators (Images used courtesy of ANSYS, Inc.).

Conservation equations

The conservation equations system (energy, momentum, continuity) for two-phase NNNF in the helical heat exchanger may be inscribed as3941:

.(ρnfVm)=0 1

ρnf is the nanofluid density and Vm is the average velocity in each section.

.(ρnfVmVm)=-P+.(μnfVm) 2

μnf is the viscosity of nanofluid.

.(ρnfcVmT)=.(knfT) 3

The supposition of dynamic viscosity behavior for the two-phase NNNF flow in solution field is observed by using of the non-Newtonian two-phase power-law method. The two-phase non-Newtonian power-law viscosity technique can be written as42:

τ=Kγ˙n 4

For viscosity and conductivity used equations in45.

The Reynolds stress is molded using standard k-ε turbulence model.

-ρuiuj¯=μtuixj+ujxi 5
μt=ρCμk2ε 6
xi[ρkui]=xjμ+μtσkkxj+Gk-ρε 7
xi[ρεui]=xjμ+μtσεεxj+C1εεkGk+C2ερε2k 8

Gk is the turbulent kinetic energy generation rate and ρε is the dissipation rate and defined by:

Gk=-ρuiuj¯ujxi 9

The coefficients Prt = 0.9, σε = 1.3, σk = 1.0, C1ε = 1.44, C2ε = 1.92 and Cμ = 0.09 are selected as experimental coefficients in turbulence transport equation39.

Due to analyze the two-phase NNNF flow characteristics and HTR of several turbulators shapes in the helical heat exchanger, definite descriptions have been assumed as4149:

The Reynolds number (Re) has been expressed as:

Re=ρnfVmDhμnf 10

where Vm is fluid mean velocity.

The mean predicted Nusselt number (Nuav):

Nuav=hDhknf 11

where hf and kf are respectively the mean predicted HTC and thermal conductivity of non-Newtonian base fluid.

The pressure drop between the inlet and outlet is:

Δp=pavg,inlet-pavg,outlet 12

The average friction factor is33:

f=2LDhΔpρnfVm2 13

The Thermal and hydraulic performance evaluation criteria (THPEC) is employed to calculate the performance of turbulators to improve HTR assuming the accretion of pumping power. Hence, Nuav and mean friction factor are considered as follows4149:

THPEC=NuavNuav,sffs-13 14

where Nuav and Nuav,s are the predicted mean Nusselt number for helical channel equipped with turbulators or filled with two-phase NNNF and the smooth channel or channel filled with non-Newtonian base fluid. Also, f and fs are the friction factor for channel equipped with turbulators or filled with two-phase NNNF and the smooth channel or channel filled with non-Newtonian base fluid, respectively.

HTR in helical heat exchanger occupied with NNNF for two-phase flow is obtainable as follow39:

Q˙=m˙Cps(Ts,in-Ts,out) 15

The commercial finite volume-based CFD code ANSYS FLUENT (version 18.1) has been employed in current investigation to perform the simulations. For the numerical approach, the velocity–pressure coupled equations are employed. Due to achieve a noteworthy accuracy, SIMPLEC algorithm is implemented. The maximum 10−8 error is considered for all parameters to economize the numerical procedure. The Eulerian-Eulerian single-fluid Two-Phase Model (TPM) are used to solve the governing equations. It should be noted that the phases linking is resilient, and particle prudently shadow the non-Newtonian two-phase nanofluid flow4656.

The Eulerian–Eulerian two-phase method is based on the assumption that the base fluid particles and nanoparticles move at different speeds but have the same temperature. In fact, in this method, two momentum equations and one energy equation are solved.

For fluid boundary layer influences simulating near walls, solution the Navier–Stokes relations employing evaluate skin friction and the k–ε turbulence model in fluid fields a wall function approach has been employed in Launder and Spalding57 approach. However, the ANSYS FLUENTs Flow Simulation (SWFS), instead of using logarithmic profile, employs Van-Driest’s profiles. Besides, a Two-Scale Wall Functions (2SWF) technique has been implemented to express a turbulent and fluid boundary layers profile compared to Driest58 model. More than ten the laminar boundary layers simulation has been completed employing Navier–Stokes equations for cells quantities. Driest58 and Van Driest mixing length employs following dependency of the dimensionless longitudinal velocity u+ on the dimensionless wall distance y+ to precede turbulent boundary layers from the ANSYS FLUENTs Flow Simulations.

u+=uτwρ0y+2dη1+1+4K2η21-e-ηAv2 16

where Av is the Van Driest coefficient and is equal to 26. Moreover, K is the Karman constant and is equal to 0.4504. The diffusive heat flux and be determined by the following equation51:

qi=μPr+μtσChxii=1,2,3 17

in which, h refers to the thermal enthalpy, σc is the Stephan-Boltzmann constant and is equal to 0.9. Moreover, Pr indicates the Prandtl number. It must be mentioned that available equations express both regimes of laminar and turbulent flows. For purely laminar flow, μt and k are zero. The employed boundary conditions for two-phase non-Newtonian nanofluid HTR and flow distribution simulation are expressed as:

  1. Total solid domains are known as non-slip conditions.

  2. The shell wall is assumed adiabatic.

  3. The velocity inlet boundary condition has been set for the inlet section of the channel.

  4. Pressure outlet boundary condition is applied to the channel outlet.

The inlet fluid temperature for the helical heat exchanger kept constant at 300 K, while the outlet pressure of nanofluid is kept at 100 kPa. The non-Newtonian HTR is H2O 99.5%:0.5% CMC. To achieve the most efficient NNNF in the current study, Al2O3 nanoparticles are added to the non-Newtonian base fluid in different volume concentrations of 1 to 4% with diameters of 20, 30, 40 and 50 nm (Table 1). Also, Fig. 4 shows schematic diagram of boundary conditions in studied helical heat exchanger.

Table 1.

The thermophysical properties of the non-Newtonian base fluid and nanoparticles59,60.

Material ρ (kg/m3) cp (kJ/kg·K) k (W/m·K) μ0 (Pa.s)
Pure Water 997.1 4.179 613 × 10–3 1 × 10–3
CMC 700 0.715 0.15 × 10–3 1.5
Al2O3 3970 0.765 40 -

Figure 4.

Figure 4

Schematic diagram of boundary conditions in studied helical heat exchanger (Images used courtesy of ANSYS, Inc.).

Model validation

The unstructured tetrahedral grid has been designated for the domain because of the complex space of two-phase flow NNNF near walls (see Fig. 5). Table 2 presents the results of the grid study for the conventional collector with water as working fluid using six grid resolutions. The Table demonstrates that the grid resolution of 3,132,341 can provide an excellent agreement between the numerical process cost and the accuracy.

Figure 5.

Figure 5

The images of unstructured tetrahedral grids in present study (Images used courtesy of ANSYS, Inc.).

Table 2.

Grid independence test for sheet and tube collector.

No Nodes Nu
1 482,154 83.58
2 812,010 70.92
3 1,565,841 67.44
4 2,245,615 58.82
5 2,945,462 56.61
6 3,132,341 56.39
7 3,571,657 56.28

The CFD code verification was done by comparing previous numerical and experimental data and the current study. Figure 6 compares the current findings and the experimental results of Kim et al.61 and numerical ones of Karimi et al.40.

Figure 6.

Figure 6

Velocity contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm) (Images used courtesy of ANSYS, Inc.).

Table 3 also compares the present results with those of previous works39 and Dittus-Boelter equation (Nu = 0.023Re0.8 Pr0.4) for a tube saturated with pure water and nanofluid, indicating excellent agreement between the previous results and the present ones.

Table 3.

Comparison between the present results and those of previous works39 and Dittus-Boelter equation.

Dittus-Boelter Mohammed et al.39 Present study
Re = 2400 21 18 19.6
Re = 3600 30 25.5 27.4
Re = 5600 42 40.5 39.7
Re = 9000 62 57.6 59

Results and discussion

In this section, usage of corrugated wall helical heat exchanger with different turbulators shapes is investigated and in then usage of nanofluid as heat transfer fluid with different φ and diameters is analyzed. In the first stage some contours are reported and the fluid flow and heat transfer field are analyzed. Figure 6 shows velocity contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm). Figure 7 demonstrates pressure contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm). Figure 8 illustrates temperature contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm). Figure 9 represents velocity contour in smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm).

Figure 7.

Figure 7

Pressure contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm) (Images used courtesy of ANSYS, Inc.).

Figure 8.

Figure 8

Temperature contours in some cross-sections of smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm) (Images used courtesy of ANSYS, Inc.).

Figure 9.

Figure 9

Velocity contour in smooth-wall helical heat exchanger filled with two-phase NNNF (φ = 1% and dnp = 20 nm) (Images used courtesy of ANSYS, Inc.).

Optimum geometry

Figure 10 represents geometrical effects on THPEC index variation versus Re in helical heat exchanger filled with base fluid. This figure shows that using corrugated channel in helical heat exchanger has a significant influence on THPEC index of heat exchanger and can improve the THPEC index in heat exchanger about 10%. Also, it is found that the THPEC index value always increases by increase of Re. Therefore, there is an optimum Re, in that the maximum THPEC value is achieved in is Re = 5000. It is clear that in case of using turbulators two parameters have increase: Nuav and pressure reduction penalty. The vortexes and turbulent sub-layers increase the HTC in channel and also lead to more pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of turbulators is in view point of thermal and hydraulic performance appropriate and efficient. The THPEC index can also help us to analyze the performance of using nanofluid in heat exchangers. If the THPEC will more than 1, employing nanofluid is in view point of thermal and hydraulic performance appropriate and efficient. Therefore, in the next step usage of nanofluid in heat exchanger is investigated. Figure 11 illustrates the THPEC variation versus Re in helical heat exchanger saturated with base fluid and nanofluid (φ = 1% and dnp = 20 nm) and equipped with common turbulators. This figure shows that using nanofluid (φ = 1% and dnp = 20 nm) in helical heat exchanger equipped with common turbulators has a considerable influence on the THPEC of heat exchanger and can improve the THPEC index in heat exchanger about 11%. Also, it is found that the PEC index value always increases by increase of Re. Therefore, there is an optimum Re, in that the maximum THPEC value is achieved in is Re = 5000. It is clear that in case of employing nanofluid two parameters have increase: Nuav and pressure reduction penalty. The more conductive HTC of nanofluid increase the HTC in channel and the more dynamic viscosity of nanofluid lead to more pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of nanofluid is in view point of thermal and hydraulic performance appropriate and efficient.

Figure 10.

Figure 10

Geometrical effects on THPEC variation versus Re in helical heat exchanger filled with base fluid.

Figure 11.

Figure 11

The THPEC index variation versus Re in helical heat exchanger filled with base fluid and nanofluid (φ = 1% and dnp = 20 nm).

Figure 9 demonstrates the THPEC variation versus Re in three different helical heat exchangers filled with nanofluid (φ = 1% and dnp = 20 nm). This figure shows that using turbulators in helical heat exchanger has a considerable influence on the THPEC of heat exchanger.

It is clear that in case of employing turbulators two parameters have increase: heat transfer rate (Nuav) and pressure reduction penalty. The vortexes and turbulent sub-layers increase the HTC in channel and also lead to more pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the PEC is more than 1, usage of turbulators is in view point of thermal and hydraulic performance appropriate and efficient. Hence it should be noted that in case of using novel turbulators, the value of pressure drop penalty is less than in case of using common turbulators. Therefore, employing novel turbulators leads to more THPEC value than the other corrugated model. It is realized that in case of using novel configuration of turbulators, the THPEC values during all Re are more than other models, which is followed with common turbulators configuration and smooth channel. Also, it is found that the THPEC index value always increases by increase of Re. Therefore, there is an optimum Re, in that the maximum THPEC value is achieved in is Re = 5000.

Optimum nanofluid

In this section different characteristics of nanofluid flow (nanoparticles volume fractions and diameters) are analyzed according to THPEC index.

Figure 10 shows the THPEC variation versus Re in smooth channel helical heat exchanger filled with nanofluid (dnp = 20 nm) in different φ. This figure shows that using nanofluid in higher volume fractions in heat exchanger with smooth channel leads to more THPEC of heat exchanger and can improve the THPEC index in heat exchanger about 8%.

In addition, it is found that the THPEC index value always increases by increase of Re. Thus, Re = 5000 is an optimum Reynolds number, in which the maximum PEC value is achieved. Employing nanofluid in higher volume fractions two parameters have increase: Nuavg and pressure reduction penalty. The more conductive HTC of nanofluid in higher volume concentrations increase the HTC in channel and the more dynamic viscosity of nanofluid in higher volume fractions lead to higher pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of nanofluid is in view point of thermal and hydraulic performance appropriate and efficient. For the nanofluid with diameter size of 20 nm and volume fraction of 4% the maximum values of THPEC are achieved for all investigated Re, which is followed with cases φ = 3%, 2% and 1%, respectively.

Figure 11 shows the THPEC variation versus Re in helical heat exchanger with common turbulators saturated with nanofluid (dnp = 20 nm) in different volume fractions. This figure shows that using nanofluid in higher volume fractions in heat exchanger equipped with common turbulators results in higher THPEC index of heat exchanger and can improve the THPEC index in heat exchanger about 12%. Also, it is found that the THPEC index value always increases with Re. Thus, Re = 5000 is an optimum Reynolds number, in which the maximum THPEC value is achieved. Employing nanofluid in higher volume fractions two parameters have increase: Nuavg and pressure reduction penalty. More conductive HTC of nanofluid in higher volume concentrations increase the HTC in channel and the more dynamic viscosity of nanofluid in higher volume fractions lead to more pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of nanofluid is in view point of thermal and hydraulic performance appropriate and efficient. For the nanoparticles with diameter size of 20 nm and volume fraction of 4% the maximum values of THPEC are achieved for all investigated Re, which is followed with cases φ = 3%, 2% and 1%, respectively.

Figure 12 shows the THPEC variation versus Re in helical heat exchanger with novel turbulators saturated with nanofluid (dnp = 20 nm) in different volume fractions. This figure shows that using nanofluid in higher volume fractions in helical heat exchanger equipped with novel turbulators results in higher THPEC index of heat exchanger and can improve the THPEC index in heat exchanger about 13%. Also, it is found that the THPEC index value always increases by increase of Re. Thus, Re = 5000 is an optimum Reynolds number, in which the maximum THPEC value is achieved. Employing nanofluid in higher volume fractions two parameters have increase: Nuavg and pressure reduction. The more conductive HTC of nanofluid in higher volume concentrations increase the HTC in channel and the more dynamic viscosity of nanofluid in higher volume fractions lead to higher pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of nanofluid is in view point of thermal and hydraulic performance appropriate and efficient. For the nanofluid with diameter size of 20 nm and volume fraction of 4% the maximum values of THPEC are achieved during all investigated Re, which is followed with cases φ = 3%, 2% and 1%, respectively.

Figure 12.

Figure 12

The THPEC index variation versus Re in three different helical heat exchangers filled with nanofluid (φ = 1% and dnp = 20 nm).

Figures 13, 14, 15 and 16 show the THPEC variation versus Re in helical heat exchanger with novel turbulators saturated with nanofluid (φ = 4%) in different nanoparticles diameters. This figure reveals that using nanofluid in higher nanoparticles diameters in heat exchanger with novel turbulators leads to higher THPEC index of heat exchanger and can improve the THPEC index in heat exchanger about 15%. Also it is found that the THPEC index value always increases by increase of Re. Thus, Re = 5000 is an optimum Reynolds number, in which the maximum THPEC value is achieved. Employing nanofluid in higher nanoparticles diameters two parameters have increase: Nuavg and pressure reduction penalty. The more conductive HTC of nanofluid in higher nanoparticles diameters increase the HTC in channel and the more dynamic viscosity of nanofluid in higher nanoparticles sizes lead to more pressure drop in channel. But the THPEC index analyze the both above parameters with each other and when the THPEC is more than 1, usage of nanofluid is in view point of thermal and hydraulic performance appropriate and efficient. For the nanofluid with diameter size of 50 nm and volume fraction of 4% the maximum values of THPEC are achieved for all investigated Re, which is followed with cases dnp = 40 nm, 30 nm and 20 nm, respectively48.

Figure 13.

Figure 13

The THPEC variation versus Re in smooth channel helical heat exchanger saturated with nanofluid (dnp = 20 nm) in different volume fractions.

Figure 14.

Figure 14

The THPEC variation versus Re in helical heat exchanger equipped with common turbulators saturated with nanofluid (dnp = 20 nm) in different volume fractions.

Figure 15.

Figure 15

The THPEC variation versus Re in helical heat exchanger with novel turbulators saturated with nanofluid (dnp = 20 nm) in different volume fractions.

Figure 16.

Figure 16

The THPEC variation versus Re in helical heat exchanger with novel turbulators saturated with nanofluid (φ = 4%) in different nanoparticles diameters.

Finally, usage of H2O 99.5%:0.5% CMC/Al2O3 nanofluid in nanoparticle volume concentration of φ = 4% and nanoparticle diameter of dnp = 50 nm through helical heat exchanger equipped with corrugated channel with novel turbulators is suggested in paper as the optimum mode; with the maximum THPEC index at Re = 5000.

Also Fig. 17 illustrates economic, the THPEC index variation at Re = 5000 in helical heat exchanger with novel turbulators saturated with nanofluid (φ = 4% and dnp = 50 nm) in comparison with basic system. This figure shows that using novel heat exchanger instead of the basic smooth system, the thermal properties (by considering Nusselt number) increases about 210%, the hydraulic performance (friction factor) reduces about 28%, performance evaluation criteria index increases about 57% and the material consumption (in case of similar thermal–hydraulic performance) decreases about 31%. In another word, for the basic and novel system which has same efficiencies, the novel one has lower length and consequently 31% lower material.

Figure 17.

Figure 17

Economic and THPEC variation at Re = 5000 in helical heat exchanger with novel turbulators saturated with nanofluid (φ = 4% and dnp = 50 nm) in comparison with basic system.

Conclusion

Thermal–hydraulic analysis of a helical heat exchanger with novel turbulators saturated with two-phase NNNF has been done. The major obtained results are:

  • Using corrugated channel in helical heat exchanger has a considerable influence on the THPEC index of heat exchanger and can improve the THPEC index in heat exchanger.

  • Re = 5000 is an optimum Reynolds number, in which the maximum THPEC value is achieved.

  • It is clear that in case of using turbulators two parameters have increase: heat transfer rate (Nuavg) and pressure reduction penalty.

  • In case of employing nanofluid two parameters have increase: Nuav and pressure reduction penalty.

  • For the nanofluid with constant volume fraction, the maximum values of THPEC are achieved for all investigated Re for nanoparticles diameter of 50 nm, which is followed with cases φ = 3%, 2% and 1%, respectively.

  • For the nanofluid with constant diameter size, the maximum values of THPEC are achieved during all investigated Re for volume fraction of 4%, which is followed with cases dnp = 40 nm, 30 nm and 20 nm, respectively.

  • Usage of H2O 99.5%:0.5% CMC/Al2O3 nanofluid in nanoparticle volume concentration of φ = 4% and nanoparticle diameter of dnp = 50 nm through helical heat exchanger equipped with corrugated channel with novel turbulators is suggested in paper as the optimum mode; with the maximum THPEC index at Re = 5000.

  • For the basic and novel system which has same efficiencies, the novel one has lower length and consequently 31% lower material.

Acknowledgements

The authors gratefully acknowledge financial support from the German Research Foundation (DFG).

Symbols

A

Area of surface (m2)

cP

Specific heat (J/kgK)

Dh

Hydraulic diameter (m)

d

Diameter of nanoparticles (nm)

f

Friction factor

hbf

Heat transfer coefficient of base fluid

k

Thermal conductivity (W/mK)

knp

Thermal conductivity of nanoparticle

p

Pressure (Pa)

Q

Heat flux (W)

Re

Reynolds number

Renp

Reynolds number of nanoparticle

T

Temperature (K)

u

Velocity

Vm

Velocity

Greek symbols

α

Thermal diffusion

μ

Dynamic viscosity (Ns/m2)

ρ

Density (kg/m3)

φ

Nanoparticles volume fraction

Subscriptions

bf

Base fluid

nf

Nanofluid

np

Nanoparticle

Author contributions

M.I., E.A., T.S., A.B., Y.C., and G.C. wrote the manuscript. M.I., E.A., T.S., A.B., Y.C., and G.C. provided critical feedback and helped shape the research, analysis, and manuscript. All authors discussed the results and commented on the manuscript.

Funding

Open Access funding enabled and organized by Projekt DEAL.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Yu-Ming Chu, Email: chuyuming@zjhu.edu.cn.

Goshtasp Cheraghian, Email: g.cheraghian@tu-braunschweig.de.

References

  • 1.Arie MA, Hymas DM, Singer F, Shooshtari AH, Ohadi M. An additively manufactured novel polymer composite heat exchanger for dry cooling applications. Int. J. Heat Mass Transf. 2020;147:118889. doi: 10.1016/j.ijheatmasstransfer.2019.118889. [DOI] [Google Scholar]
  • 2.Bezaatpour M, Rostamzadeh H. Heat transfer enhancement of a fin-and-tube compact heat exchanger by employing magnetite ferrofluid flow and an external magnetic field. Appl. Therm. Eng. 2020;164:114462. doi: 10.1016/j.applthermaleng.2019.114462. [DOI] [Google Scholar]
  • 3.Abeykoon C. Compact heat exchangers – Design and optimization with CFD. Int. J. Heat Mass Transf. 2020;146:118766. doi: 10.1016/j.ijheatmasstransfer.2019.118766. [DOI] [Google Scholar]
  • 4.Saleh MM, Al-Dadah R, Mahmoud S, Elsayed E, El-Samni O. Wire fin heat exchanger using aluminium fumarate for adsorption heat pumps. Appl. Therm. Eng. 2020;164:114426. doi: 10.1016/j.applthermaleng.2019.114426. [DOI] [Google Scholar]
  • 5.Hagen BAL, Nikolaisen M, Andresen T. A novel methodology for Rankine cycle analysis with generic heat exchanger models. Appl. Therm. Eng. 2020;165:114566. doi: 10.1016/j.applthermaleng.2019.114566. [DOI] [Google Scholar]
  • 6.Larwa B, Kupiec K. Heat transfer in the ground with a horizontal heat exchanger installed – Long-term thermal effects. Appl. Therm. Eng. 2020;164:114539. doi: 10.1016/j.applthermaleng.2019.114539. [DOI] [Google Scholar]
  • 7.Naicker SS, Rees SJ. Long-term high frequency monitoring of a large borehole heat exchanger array. Renewable Energy. 2020;145:1528–1542. doi: 10.1016/j.renene.2019.07.008. [DOI] [Google Scholar]
  • 8.Warner J, Liu X, Shi L, Qu M, Zhang M. A novel shallow bore ground heat exchanger for ground source heat pump applications—Model development and validation. Appl. Therm. Eng. 2020;164:114460. doi: 10.1016/j.applthermaleng.2019.114460. [DOI] [Google Scholar]
  • 9.Hu Y, Heiselberg PK, Johra H, Guo R. Experimental and numerical study of a PCM solar air heat exchanger and its ventilation preheating effectiveness. Renewable Energy. 2020;145:106–115. doi: 10.1016/j.renene.2019.05.115. [DOI] [Google Scholar]
  • 10.Kumar Agrawal K, Misra R, Das Agrawal G. Improving the thermal performance of ground air heat exchanger system using sand-bentonite (in dry and wet condition) as backfilling material. Renewable Energy. 2020;146:2008–2023. doi: 10.1016/j.renene.2019.08.044. [DOI] [Google Scholar]
  • 11.Wen Z-X, Lv Y-G, Li Q, Zhou P. Numerical study on heat transfer behavior of wavy channel supercritical CO2 printed circuit heat exchangers with different amplitude and wavelength parameters. Int. J. Heat Mass Transf. 2020;147:118922. doi: 10.1016/j.ijheatmasstransfer.2019.118922. [DOI] [Google Scholar]
  • 12.Chu W-X, Sheu W-J, Hsu C-C, Wang C-C. Airside performance of sinusoidal wavy fin-and-tube heat exchangers subject to large-diameter tubes with round or oval configuration. Appl. Therm. Eng. 2020;164:114469. doi: 10.1016/j.applthermaleng.2019.114469. [DOI] [Google Scholar]
  • 13.Yu C, Zhang H, Zeng M, Wang R, Gao B. Numerical study on turbulent heat transfer performance of a new compound parallel flow shell and tube heat exchanger with longitudinal vortex generator. Appl. Therm. Eng. 2020;164:114449. doi: 10.1016/j.applthermaleng.2019.114449. [DOI] [Google Scholar]
  • 14.Habibi M, Amadeh A, Hakkaki-Fard A. A numerical study on utilizing horizontal flat-panel ground heat exchangers in ground-coupled heat pumps. Renewable Energy. 2020;147(1):996–1010. doi: 10.1016/j.renene.2019.09.040. [DOI] [Google Scholar]
  • 15.Kerme ED, Fung AS. Heat transfer simulation, analysis and performance study of single U-tube borehole heat exchanger. Renewable Energy. 2020;145:1430–1448. doi: 10.1016/j.renene.2019.06.004. [DOI] [Google Scholar]
  • 16.Mohammed HA, Gunnasegaran P, Shuaib NH. Numerical simulation of heat transfer enhancement in wavy microchannel heat sink. Int. Commun. Heat Mass Transf. 2011;38(1):63–68. doi: 10.1016/j.icheatmasstransfer.2010.09.012. [DOI] [Google Scholar]
  • 17.Shahzad Nazir M, Shahsavar A, Afrand M, Arıcı M, Nižetić S, Ma Z, Öztop HF. A comprehensive review of parabolic trough solar collectors equipped with turbulators and numerical evaluation of hydrothermal performance of a novel model. Sustain. Energy Technol. Assess. 2021;45:101103. [Google Scholar]
  • 18.Manca O, Nardini S, Ricci D. A numerical study of nanofluid forced convection in ribbed channels. Appl. Therm. Eng. 2012;37:280–292. doi: 10.1016/j.applthermaleng.2011.11.030. [DOI] [Google Scholar]
  • 19.Rostami S, Afrand M, Shahsavar A, Sheikholeslami M, Kalbasi R, Aghakhani S, Shadloo MS, Oztop HF. A review of melting and freezing processes of PCM/nano-PCM and their application in energy storage. Energy. 2020;211:118698. doi: 10.1016/j.energy.2020.118698. [DOI] [Google Scholar]
  • 20.Niknejadi M, Afrand M, Karimipour A, Shahsavar A, MeghdadiIsfahani AH. Experimental investigation of the hydrothermal aspects of water–Fe3O4 nanofluid inside a twisted tube. J. Therm. Anal. Calorimetry. 2021;143:801–810. doi: 10.1007/s10973-020-09271-0. [DOI] [Google Scholar]
  • 21.Ahmed MA, Shuaib NH, Yusoff MZ, Al-Falahi AH. Numerical investigations of flow and heat transfer enhancement in a corrugated channel using nanofluid. Int. Commun. Heat Mass Transf. 2011;38(10):1368–1375. doi: 10.1016/j.icheatmasstransfer.2011.08.013. [DOI] [Google Scholar]
  • 22.Li ZX, Shahsavar A, Al-Rashed AAAA, Kalbasi R, Afrand M, Talebizadehsardari P. Multi-objective energy and exergy optimization of different configurations of hybrid earth-air heat exchanger and building integrated photovoltaic/thermal system. Energy Convers. Manag. 2019;195:1098–1110. doi: 10.1016/j.enconman.2019.05.074. [DOI] [Google Scholar]
  • 23.Niknejadi M, Afrand M, Karimipour A, Shahsavar A, Isfahani AHM. An experimental study on the cooling efficiency of magnetite–water nanofluid in a twisted tube exposed to a rotating magnetic field. J. Therm. Anal. Calorim. 2020;1:1–17. [Google Scholar]
  • 24.AbbasianArani AA, Sadripour S, Kermani S. Nanoparticle shape effects on thermal-hydraulic performance of boehmite alumina nanofluids in a sinusoidal–wavy mini-channel with phase shift and variable wavelength. Int. J. Mech. Sci. 2017;128–129:550–563. [Google Scholar]
  • 25.Sadripour S, Ghorashi SA, Estajloo M. Numerical investigation of a cavity equipped with corrugated heat source: A full convection-conduction-radiation coupling. Am. J. Aerosp. Eng. 2017;4(3):27–37. doi: 10.11648/j.ajae.20170403.11. [DOI] [Google Scholar]
  • 26.Heris SZ, Esfahany MN, Etemad G. Numerical investigation of nanofluid laminar convective heat transfer through a circular tube. Numer. Heat Transf. Part A Appl. 2017;52(11):1043–1058. doi: 10.1080/10407780701364411. [DOI] [Google Scholar]
  • 27.Heris SZ, Etemad SG, Esfahany MN. Convective heat transfer of a Cu/water nanofluid flowing through a circular tube. Exp. Heat Transf. 2019;22(4):217–227. doi: 10.1080/08916150902950145. [DOI] [Google Scholar]
  • 28.Keshavarz Moraveji M, Haddad SMH, Darabi M. Modeling of forced convective heat transfer of a non-Newtonian nanofluid in the horizontal tube under constant heat flux with computational fluid dynamics. Int. Commun. Heat Mass Transf. 2012;39:995–999. doi: 10.1016/j.icheatmasstransfer.2012.05.003. [DOI] [Google Scholar]
  • 29.Akbari OA, Toghraie D, Karimipour A, Marzban A, Ahmadi GR. The effect of velocity and dimension of solid nanoparticles on heat transfer in non-Newtonian nanofluid. Phys. E. 2017;86:68–75. doi: 10.1016/j.physe.2016.10.013. [DOI] [Google Scholar]
  • 30.Minea AA. Uncertainties in modeling thermal conductivity of laminar forced convection heat transfer with water alumina nanofluids. Heat Mass Transf. 2014;68:78–84. doi: 10.1016/j.ijheatmasstransfer.2013.09.018. [DOI] [Google Scholar]
  • 31.Zeinali Heris S, Etemad SGh, Nasr Esfahany M. Numerical investigation of nanofluid laminar convective heat transfer through a circular tube. Numer. Heat Transf. Part A: Appl. 2007;52(11):1043–1058. doi: 10.1080/10407780701364411. [DOI] [Google Scholar]
  • 32.Gholami MR, Akbari OA, Marzban A, et al. The effect of rib shape on the behavior of laminar flow of oil/MWCNT nanofluid in a rectangular microchannel. J. Therm. Anal. Calorim. 2018;134:1611–1628. doi: 10.1007/s10973-017-6902-3. [DOI] [Google Scholar]
  • 33.Zadeh AD, Toghraie D. Experimental investigation for developing a new model for the dynamic viscosity of silver/ethylene glycol nanofluid at different temperatures and solid volume fractions. J Therm Anal Calorim. 2018;131:1449–1461. doi: 10.1007/s10973-017-6696-3. [DOI] [Google Scholar]
  • 34.Khodadadi H, Toghraie D, Karimipour A. Effects of nanoparticles to present a statistical model for the viscosity of MgO-Water nanofluid. Powder Technol. 2019;342:166–180. doi: 10.1016/j.powtec.2018.09.076. [DOI] [Google Scholar]
  • 35.Goodarzi M, Toghraie D, Reiszadeh M, et al. Experimental evaluation of dynamic viscosity of ZnO–MWCNTs/engine oil hybrid nanolubricant based on changes in temperature and concentration. J Therm. Anal. Calorim. 2019;136:513–525. doi: 10.1007/s10973-018-7707-8. [DOI] [Google Scholar]
  • 36.Sarlak R, Yousefzadeh S, Ali Akbari O, Toghraie D, Sarlak S, Assadi F. The investigation of simultaneous heat transfer of water/Al2O3 nanofluid in a close enclosure by applying homogeneous magnetic field. Int. J. Mech. Sci. 2017;133:674–688. doi: 10.1016/j.ijmecsci.2017.09.035. [DOI] [Google Scholar]
  • 37.Arasteh H, Mashayekhi R, Toghraie D, et al. Optimal arrangements of a heat sink partially filled with multilayered porous media employing hybrid nanofluid. J. Therm. Anal. Calorim. 2019;137:1045–1058. doi: 10.1007/s10973-019-08007-z. [DOI] [Google Scholar]
  • 38.Saeedi AH, Akbari M, Toghraie D. An experimental study on rheological behavior of a nanofluid containing oxide nanoparticle and proposing a new correlation. Phys. E: Low-dimens. Syst. Nanostruct. 2018;99:285–293. doi: 10.1016/j.physe.2018.02.018. [DOI] [Google Scholar]
  • 39.Mohammed HA, Abuobeidab IAMA, Vuthaluru HB, Liua S. Two-phase forced convection of nanofluids flow in circular tubes using convergent and divergent conical rings inserts. Int. Commun. Heat Mass Transfer. 2019;101:10–20. doi: 10.1016/j.icheatmasstransfer.2018.12.010. [DOI] [Google Scholar]
  • 40.Karimi A, Al-Rashed AAAA, Afrand M, Mahian O, Wongwises S, Shahsavar A. The effects of tape insert material on the flow and heat transfer in a nanofluid-based double tube heat exchanger: Two-phase mixture model. Int. J. Mech. Sci. 2019;156:397–409. doi: 10.1016/j.ijmecsci.2019.04.009. [DOI] [Google Scholar]
  • 41.Sheikholeslami M, Rokni HB. Influence of melting surface on MHD nanofluid flow by means of two phase model. Chin. J. Phys. 2018;55(4):1352–1360. doi: 10.1016/j.cjph.2017.06.008. [DOI] [Google Scholar]
  • 42.Sheikholeslami M, Rokni HB. Nanofluid two phase model analysis in existence of induced magnetic field. Int. J. Heat Mass Transf. 2017;107:288–299. doi: 10.1016/j.ijheatmasstransfer.2016.10.130. [DOI] [Google Scholar]
  • 43.Alsarraf J, Moradikazerouni A, Shahsavar A, Afrand M, Salehipour H, Tran MD. Hydrothermal analysis of turbulent boehmite alumina nanofluid flow with different nanoparticle shapes in a minichannel heat exchanger using two-phase mixture model. Phys. A. 2019;520:275–288. doi: 10.1016/j.physa.2019.01.021. [DOI] [Google Scholar]
  • 44.Ansys® Academic Research Mechanical, Release 18, Help System, Coupled Field Analysis Guide, ANSYS, Inc.
  • 45.Barnoon P, Toghraie D, Eslami F, Mehmandoust B. Entropy generation analysis of different nanofluid flows in the space between two concentric horizontal pipes in the presence of magnetic field: Single-phase and two-phase approaches. Comput. Math. Appl. 2019;77(3):662–692. doi: 10.1016/j.camwa.2018.10.005. [DOI] [Google Scholar]
  • 46.Arani AAA, Moradi R. Shell and tube heat exchanger optimization using new baffle and tube configuration. Appl. Thermal Eng. 2019;157:113736. doi: 10.1016/j.applthermaleng.2019.113736. [DOI] [Google Scholar]
  • 47.Li B, Zhang W, Zhu L, Lin Y, Bai B. Effects of nanoparticle migration on non-Newtonian nanofluids in a channel with multiple heating and cooling regions. Int. J. Heat Mass Transf. 2017;107:836–845. doi: 10.1016/j.ijheatmasstransfer.2016.11.091. [DOI] [Google Scholar]
  • 48.Santra AK, Sen S, Chakraborty N. Study of heat transfer due to laminar flow of copper–water nanofluid through two isothermally heated parallel plates. Int. J. Thermal Sci. 2009;48:391–400. doi: 10.1016/j.ijthermalsci.2008.10.004. [DOI] [Google Scholar]
  • 49.Kamali R, Binesh AR. Numerical investigation of heat transfer enhancement using carbon nanotube non-Newtonian nanofluids. Int. Commun. Heat Mass Transfer. 2010;37:1153–1157. doi: 10.1016/j.icheatmasstransfer.2010.06.001. [DOI] [Google Scholar]
  • 50.Asadi A, Pourfatt F. Heat transfer performance of two oil-based nanofluids containing ZnO and MgO nanoparticles; a comparative experimental investigation. Powder Technol. 2019;343:296–308. doi: 10.1016/j.powtec.2018.11.023. [DOI] [Google Scholar]
  • 51.S.V., Patankar, "Numerical Heat Transfer and Fluid Flow", Taylor & Francis Group, 1980.
  • 52.Garoosi F. Presenting two new empirical models for calculating the effective dynamic viscosity and thermal conductivity of nanofluids. Powder Technol. 2020;366:788–820. doi: 10.1016/j.powtec.2020.03.032. [DOI] [Google Scholar]
  • 53.Garoosi F, MehdiRashidi M. Two phase flow simulation of conjugate natural convection of the nanofluid in a partitioned heat exchanger containing several conducting obstacles. Int. J. Mech. Sci. 2017;130:282–306. doi: 10.1016/j.ijmecsci.2017.06.020. [DOI] [Google Scholar]
  • 54.Garoosi F, Talebi F. Numerical analysis of conjugate natural and mixed convection heat transfer of nanofluids in a square cavity using the two-phase method. Adv. Powder Technol. 2017;28(7):1668–1695. doi: 10.1016/j.apt.2017.04.006. [DOI] [Google Scholar]
  • 55.Garoosi F, Talebi F. Numerical simulation of conjugate conduction and natural convection heat transfer of nanofluid inside a square enclosure containing a conductive partition and several disconnected conducting solid blocks using the Buongiorno's two phase model. Powder Technol. 2017;317:48–71. doi: 10.1016/j.powtec.2017.04.042. [DOI] [Google Scholar]
  • 56.Garoosi F, Mehdi Rashidi M. Conjugate-mixed convection heat transfer in a two-sided lid-driven cavity filled with nanofluid using Manninen's two phase model. Int. J. Mech. Sci. 2017;131–132:1026–1048. doi: 10.1016/j.ijmecsci.2017.08.030. [DOI] [Google Scholar]
  • 57.Launder BE, Spalding DB. The numerical computation of turbulent flows. Comput. Methods Appl. Mech. Eng. 1974;3:269–289. doi: 10.1016/0045-7825(74)90029-2. [DOI] [Google Scholar]
  • 58.Van Driest ER. On turbulent flow near a wall. J. Aeronaut. Sci. 1956;23(11):1007–1011. doi: 10.2514/8.3713. [DOI] [Google Scholar]
  • 59.Corcione M. Empirical correlating equations for predicting the effective thermal conductivity and dynamic viscosity of nanofluids. Energy Convers. Manag. 2011;52:789–793. doi: 10.1016/j.enconman.2010.06.072. [DOI] [Google Scholar]
  • 60.Gupta S, Varshney PK. Effect of plasticizer on the conductivity of carboxymethyl cellulose-based solid polymer electrolyte. Polym. Bull. 2019;76:6169–6178. doi: 10.1007/s00289-019-02714-1. [DOI] [Google Scholar]
  • 61.Kim D, Kwon Y, Cho Y, Li C, Cheong S, Hwang Y, Lee J, Hong D, Moon S. Convective heat transfer characteristics of nanofluids under laminar and turbulent flow conditions. Curr. Appl. Phys. 2009;9(2):119–123. doi: 10.1016/j.cap.2008.12.047. [DOI] [Google Scholar]

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES