Investigating Coupled Effect of Radiative Heat Flux and Firebrand Showers on Ignition of Fuel Beds

Sayaka SUZUKI 1, Samuel, L MANZELLO 2
PMCID: PMC8174413  NIHMSID: NIHMS1700946  PMID: 34092802

Abstract

Fire spread occurs via radiation, flame contact, and firebrands. While firebrand showers are known to be a cause of spot fires which ignite fuels far from the main fire front, in the case of short distance spot fires, radiation from the main fire may play a role for firebrand induced ignition processes. Many past investigations have focused on singular effects on fire spread, and little is known about coupled effects. The coupled effect of radiative heat flux and firebrand showers on ignition processes of fuel beds is studied by using a newly developed experimental protocol. The newly developed protocol includes the addition of a radiant panel to the existing experimental setup of a firebrand generator coupled to a wind facility. Experiments were performed under an applied wind field, as the wind is a key parameter in large outdoor fire spread processes. Results show that radiant heat flux plays an important role for ignition by firebrands under 6 m/s while little effect was observed under 8 m/s.

Keywords: Firebrands, Ignition, Radiation, Large Outdoor Fires, WUI Fires, Urban Fires

1. Introduction

Large outdoor fires pose problems for societies across the world [1, 2]. Perhaps the most often in the news are wildland fires that approach urban areas. These are more simply referred to as Wildland-Urban Interface (WUI) fires [3]. In Asia and North America, some recent examples are the 2019 WUI fires that occurred in South Korea and those in 2018 in Northern California in the United States [4-6]. In Africa, in less developed countries, there have been large fires that have occurred in informal settlements [7]. For centuries there have also been large urban fires in Japan, a country with no large wildland fire problem or informal settlement situation [2].

In all of these large outdoor fires, fires spread in three mechanisms: direct flame contact, thermal radiation, and firebrands as shown in Fig. 1. Firebrands are produced and lead to enhanced fire spread processes [8-27]. Often referred to as spotting processes, firebrands are liberated from the combustion of various fuel types, such as trees, shrubs, houses, and then induce ignition of fuel sources away from the initial fire source. In the case of short distance spot fires (distance up to 500 – 750 m [28]), a potentially important aspect of the physics of ignition induced by firebrand are the coupled influence of firebrand showers and radiant heat. Many past investigations have focused on singular effects on fire spread [11, 23-27], and little is known about coupled effects.

Figure 1.

Figure 1

Fire spread mechanisms in large outdoor fires: direct flame contact, thermal radiation and firebrands

Here, the coupled effect of radiation and firebrand showers on ignition processes of fuel beds is studied by using a newly developed experimental protocol. Experiments were performed under an applied wind field, as the wind is a key parameter in large outdoor fire spread processes.

2. Experimental Description

All experiments were conducted at the National Research Institute of Fire and Disaster (NRIFD). The wind field exits from a 4.0 m diameter fan, and it is possible to generate wind speeds up to 10 m/s. The flow field was measured to be within ± 10 % of desired wind speed over a cross-section of 2.0 m by 2.0 m. To generate firebrand showers, the reduced-scale continuous-feed firebrand generator was used and installed inside NRIFD’s wind facility [29]. This apparatus is known to have the ability to produce firebrand showers often seen in actual large outdoor fires (Fig. 2). Figure 2 offers comparison of firebrands in actual WUI fires [30] and firebrands from the firebrand generator. The experimental facility was modified for this work with the new aspect being the addition of a radiant panel to provide radiant heat to the fuel beds.

Figure 2.

Figure 2

Comparison of firebrands in WUI fires (left) and firebrands from a firebrand generator under a 4 m/s wind (right). Image in left is from [30] showing WUI fires in California, USA 2018.

2.1. Experimental Apparatus

The reduced-scale continuous-feed firebrand generator consisted of two parts: the main body where combustion takes place and continuous feeding component (see Fig. 3). A conveyer was used to feed wood pieces continuously into the device and was operated at 1.0 cm/s, and wood pieces were put on the conveyer belt at 12.5 cm intervals. Douglas-fir wood pieces machined with dimensions of 7.9 mm (H) by 7.9 mm (W) by 12.7 mm (L) were used to produce firebrands. These same size wood pieces were used in past studies and have been shown to be within the projected area and the mass of firebrands measured from full-scale burning trees as projected areas obtained from actual WUI fires [31]. The wood feed rate used here was 80 g/min (mass based) or 160 /min (number based), similar to previous non-radiation assisted ignition studies [29]. As glowing firebrands were desired, the blower was set to provide an average velocity of 500 cm/s.

Figure 3.

Figure 3

Schematic of a firebrand generator embedded in the wind facility in NRIFD

The fuel beds used for ignition were 300 mm by 300 mm in size and consisted of the same Douglas-fir wood pieces used to generate firebrands (Fig. 4 (a) and (b)). These were installed inside a mock-up corner assembly lined with calcium silicate board, since the ignition of the corner assembly itself was not the goal here; only ignition induced in the wood pieces was of interest. It was observed that firebrands deposited uniformly on the fuel beds when installed inside the mock-up corner assembly. To further simplify the experiments, these wood pieces in the fuel beds were oven dried to remove moisture at 104 °C. Moisture removal was verified by measuring the temporal variation of mass loss of the wood pieces.

Figure 4.

Figure 4

Figure 4

(a) Schematic of the experimental settings. Front view (top) and Top view (bottom) are shown. Firebrand showers were produced using the reduced-scale firebrand generator installed in NIRFD’s wind facility. Fuel beds consisted of Douglas-fir pieces of uniform size.

(b) A typical experiment conducted at 8 m/s. Multiple glowing firebrands are seen depositing in the fuel bed.

To provide uniform radiant heat flux to fuel beds, an electrically operated quartz radiant panel was used. Dimensions of the radiant panel were also 300 mm by 300 mm (Fig. 4 (a) and (b)). It was mounted at a height of 440 mm from the fuel bed surface.

2.2. Experimental Condition

The two wind speeds were selected, namely 6 m/s and 8 m/s for this experimental series. The objective of the new experimental setup is to investigate the combined effect of radiative heat flux and firebrands on ignition, and therefore the wind speeds were carefully selected. Based on scoping experiments, firebrands are able to ignite fuel beds of wood pieces within 40 min under both wind speeds without radiative heat flux. Firebrand flux landing on fuel bed was measured via video recording (30 frames per second). The firebrand fluxes were 6.3 /m2 s and 9.0 /m2 s under 6 m/s and 8 m/s respectively. The characteristics of firebrands, namely the mass and the projected area of firebrands were compared. As shown in Fig. 5, the mass and the projected area of firebrands produced under 6 m/s and 8 m/s wind are similar as those are within similar mass and projected area class and the average within uncertainties.

Figure 5.

Figure 5

Characteristics of firebrands used in this study.

A custom calibration rig was designed and fabricated to quantify the radiant heat flux that the radiant panel provided at the fuel bed surface. The heat from the radiant panel was 5.76 kW (Quartz-faced Infrared Radiant Panel Heaters, Omega Engineering). The applied radiant heat flux to fuel beds with no wind was 8.5 kW/m2. This value was carefully selected. In this study, it is important to investigate the coupled effects of firebrand showers and radiant heat flux on fuel bed ignition. Naturally, if the radiant heat flux applied to the fuel beds was too high, firebrands would simply serve as piloted ignition source, as the radiant heat flux would be the dominate ignition mode. Accordingly, a series of experiments using only a radiant heater coupled with spark ignitor was undertaken to determine the limits where radiant heat flux alone in the absence of firebrand showers was capable to ignite the fuel beds used here. At 10 kW/ m2, the fuel bed was not able to be ignited by a spark within 30 min. For values above 10 kW/m2, radiant heat flux in the presence of a spark was able to produce ignition of the fuel beds. The radiant heat was measured at multiple points and found to be within 10 %.

The applied wind increases the convective heat loss from the fuel beds, so the measured heat flux to fuel beds, using a total heat flux gauge (Schmidt-Boelter gauge, Hukseflux, calibrated by the manufacturer), under 6 m/s and 8 m/s were 5.6 kW/m2 and 4.0 kW/m2, respectively. Pre-heating time was determined as the duration from the time when the radiant panel was turned on to the time to start the firebrand generator. For pre-heating times of 10 min and 20 min, the wind field was switched on 60 seconds prior to initiating combustion in the firebrand generator. Selected pre-heating time was 0 min, 10 min, and 20 min. Baseline experiments were also performed to examine the ignitions by firebrands without applied radiant heat flux. The experiments for the same condition was repeated at least 3 times.

3. Results and Discussions

Figure 4 (b) displays a picture of a typical experiment. In this picture, the applied wind speed was 8 m/s, and radiant panel was switched on at the same time as the firebrand generator, that is there was no pre-heating time. The experiments for the same condition was repeated at least 3 times, and the uncertainties were calculated based on two standard deviation.

Fig. 6 displays the time to smoldering ignition (SI) in the fuel beds a function of pre-heating time and wind speed. As mentioned above, the firebrand flux on the fuel beds differ under 6 m/s and 8 m/s (6.3 /m2 s and 9.0 /m2 s, respectively). The time to ignition did not take into account the difference of firebrand flux, so total number of firebrands per m2 required is introduced. The total number of firebrands per m2 required to achieve these ignition sequences is also displayed in Fig. 7. This was calculated by multiplying the time to SI by the firebrand flux. The time to SI was measured via video recording, from the time the first firebrand landed the fuel bed to the time the sustained SI was observed in the fuel bed. Experiments were repeated and the error bars in the figures shows the standard deviation. Here, sustained SI was defined as the start of intense smoke generation and glowing ignition of the fuel bed due to the coupled effects of accumulated firebrands and radiant heat flux. To aid in understanding, in Fig. 6 and Fig. 7, no radiant panel conditions denote that the radiant panel was not switched on. For other cases, the applied radiant heat flux to fuel beds was 8.5 kW/m2.

Figure 6.

Figure 6

Coupled effects of radiation and firebrands on smoldering ignition under different wind speeds and pre-heating time.

Figure 7.

Figure 7

Number of firebrands per m2 required for smoldering ignition under different wind speed and pre-heating time

An interesting result from these findings is that for wind speed of 6 m/s, the pre-heating due to the applied radiant heat flux to the fuel bed influenced the time to SI significantly. Yet, as the wind speed was increased to 8 m/s, the applied radiant heat flux had very little effect.

To better visualize these results, it is instrumental to describe the heat and mass transfer processes occurring in the fuel beds and firebrands. Treating the fuel bed and firebrands as a system, an energy balance gives:

Qfuel,total=Qfirebrand,comb−Qfirebrand,loss+Qfuel,rad−Qfuel,conv (1)

where Qfirebrand,comb is the heat produced from the firebrand combustion, Qfirebrand,loss is the convective and radiative heat loss from a firebrand, Qfuel,rad is the external radiant heat provided to the fuel beds, and Qfuel,conv is the convective heat transfer (cooling) to the fuel beds. Since the fuel beds were oven dried in these experiments, the term indicating the energy to remove the fuel bed moisture is omitted.

In order to ignite the fuel beds, Qfuel,total has to be equal to or greater than the heat required for the ignition, Qig. Assuming ignition occurs when the temperature of the fuel beds reaches the ignition temperature Tig, Qig may be described as follows:

Qig=ρfuelcfuelV(Tig−T0) (2)

where ρfuel is the bulk density of the fuel beds, cfuel is the specific heat capacity of fuel beds (wood), and T0 is the ambient temperature, and V is volume. Qfirebrand,comb is usually described as follows [26]:

Qfirebrand,comb=ΔH×Δmfirebrand (3)

where ΔH is the heat of combustion of a firebrand, and Δmfirebrand is the mass loss of a given firebrand. The term Qfirebrand,loss may be expressed as:

Qfirebrand,loss=[h(Tfirebrand−T0)+ϵσ(Tfirebrand4−T04)]tigAfirebrand,external (4)

where Afirebrand,external is the firebrand area exposed to wind and tig is the time to fuel bed ignition.

Qfuel,rad−Qfuel,conv=AERHF(tp+t0+tig)Afuel,external−h(Tfuel−To)(t0+(tig)Afuel,external (5)

where AERHF is the applied external radiant heat flux, Tfuel is the fuel bed temperature, tp is the pre-heating time, t0 is the time when the firebrand generator was on to first firebrand landed on the fuel bed, and Afuel,external is the fuel bed area exposed to wind. Substituting all these expressions into equation 1 yields the following:

ρfuelcfuelV(Tig−T0)=ΔH×Δmfirebrand−[h(Tfirebrand−T0)+ϵσ(Tfirebrand4−)][(T04)]tigAfirebrand,external+AERHF(tp+t0+tig)Afuel,external−h(Tfuel−To)(t0+)(tig)Afuel,external (6)

At 6 m/s, the applied radiant heat flux acts to reduce the time to SI ignition greatly with increased pre-heating time. As wind speed is increased, convection cooling to the fuel beds is increased, but the time to ignition was not influenced by the additional assistance from the applied radiant heat flux. It is believed that the increased wind speed rather changes the combustion dynamics of the firebrands by providing more oxygen and therefore alters their temperatures, resulting in enhanced combustion reactions. There is limited knowledge on the firebrand temperature or heat of combustion of a firebrand [32-34].

Manzello el al. [32] quantitatively showed that glowing firebrand surface temperature increased as the wind speed was increased. As a part of that investigation, the surface temperature of charred area on the glowing firebrand was simultaneously measured using both the thermocouple and the infrared camera [32]. The firebrand temperatures were quite sensitive to airflow. Therefore, in this work, larger firebrand temperatures were expected as the wind speed was increased from 6 m/s to 8 m/s.

Assuming the temperature of a firebrand increases with wind speed, it is known that the final mass of a firebrand under different wind speed decreases with the increasing wind speed [32]. Thus, Qfirebrand,comb is expected to increase as the wind speed increases. The temperature increase would result in the increase in Qfirebrand,loss, assuming tig is the same. From previous studies [25, 26], it is also known that the tig becomes shorter as the wind speed increases. In this case, Qfirebrand,loss may decrease depending on tig, cancelling the increase in Qfirebrand,loss by temperature increase. The external radiant heat has impact upon the fuel bed ignition. However, the convective cooling and shorter ignition time at a higher wind speed reduces this influence, which is shown in results under 8 m/s.

In every experiment in this investigation, smoldering ignition was observed to transition to flaming ignition. The time to flaming ignition in the fuel beds as function of pre-heating time and wind speed is shown in Fig 8. The total number of firebrands per m2 required to reach flaming ignition (FI) was also quantified and shown in Fig 9.

Figure 8.

Figure 8

Coupled effects of radiation and firebrands on flaming ignition under different wind speeds and pre-heating time.

Figure 9.

Figure 9

Number of firebrands per m2 required for flaming ignition under different wind speed and pre-heating time.

Fig. 10 displays the number of firebrands per m2 required for ignition versus the calculated total energy per m2 received at the fuel bed. The total energy received at the fuel bed was calculated based on the radiant heat from the radiant panel and the convective heat loss from the fuel bed, the energy from firebrands are not taken into account. Re-writing Eq. (6) as follows yields:

−[h(Tfirebrand−T0)+ϵσ(Tfirebrand4−T04)]tigAfirebrand,external+AERHF(tp+)(t0+tig)Afuel,external−h(Tfuel−To)(t0+tig)Afuel,external=−ΔH×Δmfirebrand+ρfuelcfuelV(Tig−T0) (7)

where − ΔH × Δmfirebrand + ρfuelcfuelV(Tig − T0) = constant , as well as AERHF(tp + t0 + tig)Afuel,external − h(Tfuel − To)(t0 + tig)Afuel,external can be calculated based on experimental data. The term −[h(Tfirebrand−T0)+][ϵσ(Tfirebrand4−T04)]Afirebrand,external can be considered to be constant under steady conditions. As described above, the number of firebrands per m2 required for ignition was calculated by multiplying the time to ignition by the firebrand flux. Accordingly, based on these assumptions and calculations, the data in Fig. 10 should follow a linear relationship. As may be seen, data under 6 m/s follows a linear relationship as described in Eq. (7) well. While those under 8 m/s do match the predicted trend, a more detailed heat transfer model of firebrands must be incorporated in the future.

Figure 10.

Figure 10

Total received energy per m2 to fuel beds and the number of firebrands per m2 required for ignition.

The transition to flaming ignition from smoldering ignition is a rapid exothermic gas-phase reaction. For this transition to take place, there are two key events that must be attained simultaneously, a mixture of gases and air within the flammability limit and a sufficient heat source to ignite this mixture [35-37]. It is very interesting to see how these transitions occur under coupled influences of firebrand showers and applied radiant heat. The application of applied radiant heat had the largest influence on the time to reach flaming ignition at 6 m/s. The specific times for these transitions to occur were also measured and shown in Fig. 11, along with the numbers of firebrands required (Fig. 12). For a fixed pre-heat time, additional heat needed to force this transition is provided by the ongoing firebrand showers. While there still exists no complete theory to describe this complex transition [35-37], these experiments provide well-controlled conditions to examine these important processes further.

Figure 11.

Figure 11

The specific times for transitions from smoldering ignition to flaming were measured and are shown.

Figure 12.

Figure 12

Number of firebrands per m2 required for transitions from smoldering ignition to flaming ignition under different wind speed and pre-heating time.

4. Summary

The coupled effect of radiative heat flux and firebrand showers on ignition processes of fuel beds was studied by using a newly developed experimental protocol. An interesting result from this preliminary study is that for wind speed of 6 m/s, the pre-heating time due to the applied radiant heat flux to the fuel bed influenced the time to SI significantly. Yet, as the wind speed was increased 8 m/s, the applied radiant heat flux had very little effect. It was postulated that differences in firebrand combustion dynamics may explain these differences. More work is required to quantify firebrand temperatures at higher wind speeds. Measurements of firebrand heat of combustion and mass loss profiles would also be important to better reveal the influences of combustion dynamics on applied wind speed.

5. Acknowledgments

This research is supported by MEXT/JSPS KAKENHI Grant-in-Aid for Scientific Research (C) 18K04675.

6. References

  • [1].Manzello SL, Blanchi R, Gollner MJ, Gorham D, McAllister S, Pastor E, Planas E, Reszka P, Suzuki S, (2018) ‘Summary of workshop large outdoor fires and the built environment’, Fire Safety Journal, Vol. 100, pp.76–92. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [2].Manzello SL, (2019) Summary of Workshop on Global Overview of Large Outdoor Fire Standards, NIST Special Publication (NIST SP) – 1235 10.6028/NIST.SP.1235 [DOI] [Google Scholar]
  • [3].Mell WE, Manzello SL, Maranghides A, Butry D, Rehm RG, (2010) The wildland–urban interface fire problem–current approaches and research needs, International Journal of Wildland Fire 19 (2), 238–251 [Google Scholar]
  • [4].Marlon JR et al. (2012), Long-term perspective on wildfires in the western USA Proceedings of the National Academy of Sciences, 109 E535–E543; DOI: 10.1073/pnas.1112839109 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [5].Thousands Flee South Korea Wildfire, Wildland firefighter, http://www.wildlandfirefighter.com/2019/04/05/thousands-flee-south-korea-wildfire/#gref (2020/July/06 access) [Google Scholar]
  • [6].CALFIRE 2018 Incident Archives https://www.fire.ca.gov/incidents/2018/ (2020/July/06 access)
  • [7].Walls R, Olivier G, Eksteen R (2017). Informal settlement fires in South Africa: Fire engineering overview and full-scale tests on “shacks”. Fire Safety Journal. Vol. 91, pp 997–1006. [Google Scholar]
  • [8].Maranghides M, Mell W (2009) A case study of a community affected by the Witch and Guejito Fires, NIST Technical Note (NIST TN) – 1635 10.6028/NIST.TN.1635 [DOI] [Google Scholar]
  • [9].Blanchi R, and Leonard J, (2005) Investigation of bushfire attack mechanisms resulting in house loss in the ACT Bushfire 2003. Bushfire CRC report [Google Scholar]
  • [10].Suzuki S and Manzello SL, ‘Characteristics of Firebrands Collected from Actual Urban Fires’ Fire Technology, vol. 54 (2018) pp. 1533–1546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [11].Manzello SL, Suzuki S, Gollner MJ, and Fernandez-Pello AC, The role of of firebrand combustion in large outdoor fire spread, Progress in Energy and Combustion Science,76:100801, 2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [12].Fernandez-Pello AC, Lautenberger C, Rich D, Zak C, Urban J, Hadden R, Scott S, Fereres S Spot fire ignition of natural fuel beds by hot metal particles, embers and sparks, Combust Sci Technol, 187 (1–2) (2014), pp. 269–295 [Google Scholar]
  • [13].Manzello SL, Cleary TG, Shields JR, Yang JC On the ignition of fuel beds by firebrands, Fire Mater, 30 (2006), pp. 77–87 [Google Scholar]
  • [14].Tarifa CS, del Notario PP, and Moreno FG, (1965) On the flight paths and lifetimes of burning particles of wood, Proceedings of the Combustion Institute, 10:1021–1037. [Google Scholar]
  • [15].Lee S-L, Hellman JM, (1969) Study of firebrand trajectories in a turbulent swirling natural convection plume, Combustion and Flame, 13(6):645–655. [Google Scholar]
  • [16].Albini FA, (1983) Transport of Firebrands by Line Thermals, Combustion Science and Technology 32(5–6):277–288. [Google Scholar]
  • [17].Ellis PF, (2000) The aerodynamic and combustion characteristics of eucalypt bark – a firebrand study. PhD thesis, Australian National University, Canberra, ACT [Google Scholar]
  • [18].Koo E, Linn RR, Pagni PJ, Edminster CB, (2012) Modelling firebrand transport in wildfires using HIGRAD/FIRETEC, International Journal of Wildland Fire. 21: 396–417. [Google Scholar]
  • [19].Tohidi A, and Kaye NB, (2017) Comprehensive wind tunnel experiments of lofting and downwind transport of non-combusting rod-like model firebrands during firebrand shower scenarios, Fire Safety Journal. 90: 95–111. [Google Scholar]
  • [20].Woycheese JP, Brand lofting and propagation for large-scale fires. Ph.D. Thesis, University of California, Berkeley, 2000. [Google Scholar]
  • [21].Zhou K, Suzuki S, and Manzello SL, ‘Experimental Study of Firebrand Transport’, Fire Technology, Vol. 51 (2015) pp. 785–799. [Google Scholar]
  • [22].Muraszew A, Fedele JF, Statistical model for spot fire spread, The Aerospace Corporation Report No. ATR-77758801, Los Angeles, CA, 1976. [Google Scholar]
  • [23].Manzello SL, Cleary TG, Shields JR, Yang JC Ignition of vegetation and mulch by firebrands in Wildland/Urban Interface (WUI) fires Int J Wildland Fire, 15 (2006), pp. 427–431 [Google Scholar]
  • [24].Manzello SL, Cleary TG, Shields JR, Mell W, Yang JC Experimental investigation of firebrands: generation and ignition of fuel beds Fire Saf J, 43 (2008), pp. 226–233 [Google Scholar]
  • [25].Suzuki S, Manzello SL, Kagiya K, Suzuki J, Hayashi Y Ignition of mulch beds exposed to continuous wind driven firebrand showers Fire Technol, 51 (2015), pp. 905–922 [Google Scholar]
  • [26].Yin P, Liu N, Chen H, Lozano JS, Shan Y New correlation between ignition time and moisture content for pine needles attacked by firebrands Fire Technol, 50 (2012), pp. 79–91 [Google Scholar]
  • [27].Urban JL, Song J, Santamaria S, Fernandez-Pello C Ignition of a spot smolder in a moist fuel bed by a firebrand Fire Saf J, 108 (2019), p. 102833 [Google Scholar]
  • [28].Cruz M, et al. , A Guide to Rate of Fire Spread Models for Australian Vegetation. CSIRO Land and Water Flagship Canberra ACT and AFAC Melbourne, Vic. 2015. [Google Scholar]
  • [29].Suzuki S, Manzello SL Experiments to prove the scientific-basis for laboratory standard test methods for firebrand exposure Fire Saf J, 91 (2017), pp. 784–790 [Google Scholar]
  • [30].Santoso MA, Christensen EG, Yang J and Rein G (2019) Review of the Transition From Smouldering to Flaming Combustion in Wildfires. Front. Mech. Eng 5:49. doi: 10.3389/fmech.2019.00049 [DOI] [Google Scholar]
  • [31].Manzello SL, Foote EID Characterizing firebrand exposure during wildland-urban interface fires: results of the 2007 Angora fire Fire Technol, 50 (2014), pp. 105–124 [Google Scholar]
  • [32].Manzello SL, Park SH, and Cleary TG, Investigation on the ability of glowing firebrands deposited within crevices to ignite common building materials, Fire Saf. J 44: 894–900, 2009. [Google Scholar]
  • [33].Kim DK and Sunderland P, Fire ember pyrometry using a color camera, Fire Safety Journal, Volume 106, 2019, 88–93 [Google Scholar]
  • [34].Urban JL, Vicariotto M, Dunn-Rankin D, Fernandez-Pello AC Temperature measurement of glowing embers with color pyrometry Fire Technology 55 (3), 1013–1026 [Google Scholar]
  • [35].Ohlemiller T, Smoldering combustion propagation on solid wood. Fire Safety Science, 1991; 3: 565. [Google Scholar]
  • [36].Tse SD, Fernandez-Pello AC, Miyasaka K., Controlling mechanisms in the transition from smoldering to flaming of flexible polyurethane foam. Proceedings of the Combustion Institute 1996; 26:1505–1513. [Google Scholar]
  • [37].Aldushin AP, Bayliss A, Matkowsky BJ., On the transition from smoldering to flaming. Combustion and Flame 2006; 145:579–606. [Google Scholar]