Abstract
Background
Despite considerable progress, it remains unclear why some patients admitted for COVID-19 develop adverse outcomes while others recover spontaneously. Clues may lie with the predisposition to hypoxemia or unexpected absence of dyspnea (‘silent hypoxemia’) in some patients who later develop respiratory failure. Using a recently-validated breath-holding technique, we sought to test the hypothesis that gas exchange and ventilatory control deficits observed at admission are associated with subsequent adverse COVID-19 outcomes (composite primary outcome: non-invasive ventilatory support, intensive care admission, or death).
Methods
Patients with COVID-19 (N = 50) performed breath-holds to obtain measurements reflecting the predisposition to oxygen desaturation (mean desaturation after 20-s) and reduced chemosensitivity to hypoxic-hypercapnia (including maximal breath-hold duration). Associations with the primary composite outcome were modeled adjusting for baseline oxygen saturation, obesity, sex, age, and prior cardiovascular disease. Healthy controls (N = 23) provided a normative comparison.
Results
The adverse composite outcome (observed in N = 11/50) was associated with breath-holding measures at admission (likelihood ratio test, p = 0.020); specifically, greater mean desaturation (12-fold greater odds of adverse composite outcome with 4% compared with 2% desaturation, p = 0.002) and greater maximal breath-holding duration (2.7-fold greater odds per 10-s increase, p = 0.036). COVID-19 patients who did not develop the adverse composite outcome had similar mean desaturation to healthy controls.
Conclusions
Breath-holding offers a novel method to identify patients with high risk of respiratory failure in COVID-19. Greater breath-hold induced desaturation (gas exchange deficit) and greater breath-holding tolerance (ventilatory control deficit) may be independent harbingers of progression to severe disease.
Supplementary Information
The online version contains supplementary material available at 10.1186/s13054-021-03630-5.
Keywords: Desaturation, Hypoxia, Chemosensitivity, Dyspnea, Prognosis
Background
COVID-19 outcomes are notoriously unpredictable [1]: roughly 5% of patients exhibit severe and progressive pneumonia that requires intensive care in the form of mechanical ventilatory support [2]. Favorable outcomes of serious cases rely on judicious administration of ventilatory support for those likely to benefit most [3], but such resources have become uniquely limited during peaks in the pandemic. While known risk factors for adverse outcomes include older age [2, 4–7], lower baseline pulse oxygen saturation (SpO2) [5, 7, 8], obesity [4], cardiovascular comorbidities [4–6], and inflammatory biomarkers (e.g. C-reactive protein [6]), considerable unexplained heterogeneity remains [5, 9]. A deeper understanding of why some patients deteriorate after admission while others recover with minimal intervention is needed. Such knowledge could help facilitate earlier administration and prioritization of advanced emerging medical interventions.
One of the most consistent risk factors for adverse outcomes of COVID-19 is lower baseline SpO2 [5, 7, 8], a reflection of disease-related gas exchange deficits (e.g. ventilation/perfusion [V/Q] heterogeneity). In addition to baseline SpO2, reports from Italy early in the pandemic described successful triage of patients using exertional desaturation (cardiometabolic challenge) [10–12] as a means to reveal gas exchange abnormalities. However, the role of exertional desaturation as a risk factor independent of baseline SpO2 remains unproven [12, 13]. Ground glass opacities and consolidation seen in computed tomography prior to respiratory failure [5, 14, 15] suggest that gas exchange deficits are a likely risk factor. Yet, to date, the propensity for additional rapid desaturation with a ventilatory challenge (breath-holding) has not been examined as a risk factor. In principle, breath-holding is expected to yield rapid desaturation in those with early gas exchange deficits (V/Q heterogeneity and reduced functional lung gas volumes [16–18]) beyond baseline SpO2. Moreover, in the context of anecdotal reports of “silent hypoxemia” (disproportionate tolerance of hypoxemia) as a characteristic of COVID-19 [19, 20], we and others [21, 22] considered that blunted ventilatory control (reduced chemosensitivity) may be an adverse neurophysiological consequence of infection, and could feasibly predispose to respiratory failure. By contrast, others have suggested that a robust ventilatory responses may promote patient self-inflicted lung injury (P-SILI) [23, 24], although this notion remains contentious [25]. There is a lack of available physiological data on the risks of respiratory failure associated with blunted v. robust ventilatory control in patients with COVID-19.
Accordingly, in a prospective, multi-center, observational study, we aimed to determine whether gas exchange and ventilatory control deficits in patients admitted for COVID-19 are associated with adverse outcomes of the disease (primary composite outcome of non-invasive pressure support, intensive care admission, or death). We used a simple, non-invasive, recently-validated breath-holding technique [26] to test the hypothesis that adverse outcomes are independently associated with (1) greater mean desaturation during a fixed-duration (20-s) breath-hold, and (2) reduced chemosensitivity based on greater maximal breath-hold duration [26–28]. The magnitude of the spontaneous ventilatory response following 20-s breath-holds (lower in those with reduced chemoreflex sensitivity) was also evaluated as a risk factor [26].
Methods
Participant recruitment
Fifty-seven hospitalized patients aged 18–90 year were enrolled after clinical diagnosis of COVID-19 in three different centers in northern Italy (Brescia, Milan, Pavia). Diagnosis was confirmed with a positive nasal or pharyngeal swab or with clear clinical evidence (i.e. typical signs at laboratory blood tests and computed tomography and/or chest ultrasound) when the swab result was yet not available (swab positivity was confirmed in all patients eventually). Exclusion criteria were: more-than-moderate dyspnea (Borg ≥ 4), hemodynamic instability, Brescia-COVID respiratory severity scale > 1 [29], diurnal home treatment with supplemental oxygen or ventilatory support, use of sedatives, opioids, anti-emetics or other drugs known to impact chemosensitivity, heart failure, chronic obstructive pulmonary disease, pregnancy, and inability to understand the informed consent.
Twenty-four healthy controls were contemporaneously studied in Melbourne (Monash Health), which at the time had low case rates of COVID-19. Absence of COVID-19 was assessed by medical examination. Exclusion criteria also included professional divers, singers, or trumpeters.
Breath-holding procedure and analysis
In patients, tests were performed shortly after admission, while breathing room air.
Breath-holding maneuvers were performed as described previously [26]. Briefly, while supine, participants were instructed to breathe only through the nose, hold their breath starting from residual functional capacity (FRC) and avoid deep inspiration prior to breath-holds. Ambulatory equipment designed for diagnosis of sleep apnea was used: nasal flow was recorded via an uncalibrated nasal cannula, together with digital saturation recorded via a probe with signal averaging time of 3-s or faster (8000J, Nonin, Plymouth, MN). Investigators requested ≥ 4 reliable 20-s fixed-time breath-holds and ≥ 1 maximal breath-hold (up to 90 s). Additional details are provided in Additional file 1.
Three physiological measurements were calculated (custom MATLAB software): mean desaturation (change from baseline in SpO2 after 20-s of apnea, using ensemble averaging and delay-correction), maximal breath-hold duration (largest value observed) [26], and ventilatory response (ventilatory overshoot at the second recovery breath following the 20-s breath-hold; ensemble-averaged tidal volume × rate; percent of pre-breath-hold baseline [26]). Participant flow chart is illustrated in Fig. 1.
Statistical analysis
The adverse composite outcome was reached with any occurrence of non-invasive bi-level pressure support, intensive care admission, or death. Since patients with COVID-19 who met the criteria for the adverse primary outcome ultimately received ventilatory support (non-invasive or via intubation in intensive care), we refer to these individuals herein as VS +; patients discharged without experiencing the adverse primary outcome were labelled VS − (Fig. 1).
The primary hypothesis was quantified by comparing the fully adjusted model against a reference model without breath-holding measurements using a likelihood ratio test. Significance of this single test (p < 0.05) was taken to indicate that the 3 measurements (together) explained unique heterogeneity in the primary adverse outcome after that already explained by 5 primary model covariates (baseline SpO2, BMI, age, sex, cardiovascular disease). Subsequent analysis then examined associations with individual breath-holding measures.
Additional serial modeling analysis examined associations between the adverse composite outcome and individual breath-holding measures, with progressive adjustment for other breath-holding measures and covariates. Multivariable linear regression models also examined differences in breath-holding measures between VS +, VS −, and controls, adjusting for covariates. Baseline SpO2 and mean desaturation were considered confounders in the analysis of associations between outcomes and breath-holding duration (i.e. greater desaturation was considered a confounding source of shorter breath-hold duration independent of chemosensitivity [30]).
A parsimonious model was also developed (removed covariates with high uncertainty per p > 0.2) to reduce uncertainty in the remaining model coefficients.
To illustrate that the knowledge provided could potentially help with the development of a future prediction tool, we assessed the preliminary prognostic value (discriminatory capacity) of the parsimonious model, understanding the limitations of the small dataset for this purpose. Accuracy was examined with versus without the breath-holding measures (random perturbation analysis and cross-validation).
Further details, including a priori power analysis to support the sample size, are available in the Additional file 1.
Role of the funding source
This study was not directly funded.
Results
Of those enrolled, 50/57 patients with COVID-19 and 23/24 non-COVID controls completed testing and provided data for analysis (Additional file 1). Breath-holding tests were performed on the day of enrolment. Baseline characteristics of the analyzed participants are shown in Table 1. Overall, N = 11/50 patients with COVID-19 met the primary composite outcome criteria (ventilatory support, intensive care, or death).
Table 1.
Characteristic | COVID-19 patients | Controls (N = 23) |
||
---|---|---|---|---|
All (N = 50) |
VS + (N = 11) |
VS − (N = 39) |
||
Population factors | ||||
Age, years | 59.6 ± 13.6 | 62.7 ± 7.5 | 58.8 ± 15.0 | 45.4 ± 10.6 |
Female sex, n (%) | 8 (16) | 0 (0.0) | 8 (20.5) | 14 (60.9) |
Body mass index, kg/m2 | 26.4 ± 4.0 | 28.1 ± 4.2 | 25.9 ± 3.4 | 25.2 ± 4.7 |
Caucasian or white race/ethnicity, n (%) | 44 (88) | 10 (90.9) | 34 (87.2) | 19 (82.6) |
History | ||||
History of hypertension, n (%) | 26 (52) | 9 (81.8) | 17 (43.6) | 1 (4.3) |
History of cardiovascular disease, n (%) | 4 (8) | 1 (9.1) | 3 (7.7) | 0 (0.0) |
History of diabetes, n (%) | 8 (16) | 2 (18.2) | 6 (15.4) | 0 (0.0) |
Current smoking, n (%) | 6 (12) | 3 (27.3) | 3 (7.7) | 0 (0.0) |
Current medications | ||||
β-blockers, n (%) | 4 (8) | 1 (9.1) | 3 (7.7) | 0 (0.0) |
ACE-inhibitors, n (%) | 9 (18) | 4 (36.4) | 5 (12.2) | 0 (0.0) |
ARB, n (%) | 4 (8) | 2 (18.2) | 2 (5.1) | 0 (0.0) |
Clinical presentation at admission | ||||
Baseline SpO2, % | 94.5 ± 4.6 | 89.9 ± 6.6 | 95.8 ± 2.3 | 97.6 ± 1.0 |
PaO2 at admission, mmHg* | 76.2 ± 15.3 | 71.0 ± 16.4 | 77.7 ± 14.9 | – |
PaCO2 at admission, mmHg* | 36.4 ± 5.4 | 37.0 ± 4.6 | 36.2 ± 6.0 | – |
Baseline Heart rate, beats/min | 86.8 ± 16.8 | 86.2 ± 21.0 | 86.9 ± 13.6 | – |
Baseline systolic blood pressure, mmHg | 127.3 ± 19.1 | 126.5 ± 18.8 | 127.5 ± 19.8 | – |
Baseline diastolic blood pressure, mmHg | 78.5 ± 10.8 | 74.4 ± 12.5 | 79.7 ± 10.2 | – |
Anosmia, n (%) | 11 (22.0) | 1 (9.1) | 10 (25.6) | – |
Ageusia, n (%) | 12 (24.0) | 2 (18.2) | 10 (25.6) | – |
Gastrointestinal symptoms, n (%) | 13 (26.0) | 2 (18.2) | 11 (28.2) | – |
Dyspnea presence, n (%) | 13 (26.0) | 3 (27.3) | 10 (25.6) | – |
Laboratory tests | ||||
C-reactive protein, mg/L | 20.2 ± 41.9 | 14.6 ± 23.7 | 21.8 ± 15.0 | – |
D-dimer, μg/L | 0.8 ± 0.8 | 1.1 ± 0.8 | 0.7 ± 0.9 | – |
Breath-holding measurements | ||||
Mean desaturation, % | 2.34 ± 1.78 | 4.42 ± 2.37 | 2.21 ± 1.43 | 1.57 ± 1.24 |
Maximal breath-hold duration**, s | 46.8 ± 16.9 | 51.8 ± 12.7 | 41.8 ± 14.2 | 53.0 ± 20.3 |
Recovery breath, %baseline | 188.9 ± 61.3 | 184.6 ± 81.8 | 195.0 ± 62.1 | 180.5 ± 49.4 |
Outcomes | ||||
Discharge:oxygen:ventilatory support, n | 14:36:11 | 0:11:11 | 14:25:0 | – |
Duration of hospitalization, days | 29.8 ± 17.2 | 47.4 ± 12.5 | 24.8 ± 15.3 | – |
Data are expressed as mean ± SD or as N (%). Patients who met the criteria for the adverse primary composite outcome are denoted “VS + ” (N = 4 non-invasive bi-level pressure support, N = 7 intensive care, N = 1 death). In all patients, diagnosis was confirmed with a positive nasal or pharyngeal swab. All patients admitted to ICU were administered mechanical ventilatory support; the patient who died was also in intensive care on mechanical ventilatory support. “VS − “ indicates patients discharged without meeting adverse primary outcome criteria. Average time to the primary outcome in VS + patients was 6 [2] days (median [IQR]). Non-Caucasian/Non-White race/ethnicities were black (1 VS + and 1 VS − COVID-19 patients), Hispanic (3 VS + COVID-19 patients) and Asian (1 VS − COVID-19 patient and 4 controls). Note that participants included in the table are those who provided data for all breath-holding measures. “Discharge” indicates discharge without oxygen or interventions that met criteria for the primary outcome during the hospital stay. On average, 3.8 ± 1.0 20-s breath-holds per individual were analyzed to calculate the ventilatory response variable (3.6 ± 0.9 in controls); 1.6 ± 0.6 maximal breath-holds were used to determine maximal breath-hold duration (2.1 ± 0.5 in controls); 5.2 ± 1.1 breath-holds (20-s or maximal) were used to calculate mean desaturation (6.3 ± 1.1 in controls). *Data available for 42 patients (9 VS + and 33 VS −). Abbreviations: SpO2, peripheral oxyhemoglobin saturation; PaO2, partial pressure of oxygen; PaCO2, partial pressure of carbon dioxide; ACE, angiotensin converting enzyme; ARB, angiotensin II receptor blockers. **Data shown are adjusted for baseline SpO2 and mean desaturation (regression)
Primary outcome assessment
Pre-specified primary analysis
Within COVID-19, breath-holding variables explained unique heterogeneity in the primary composite outcome adjusting for covariates (likelihood ratio 0.0073, p = 0.02 v. model without breath-holding measures; see Table 2). Specifically: (1) the odds of the composite outcome increased 3.6-fold per 1%Hb greater mean desaturation (log-odds [β ± SEM] = 1.27 ± 0.59 per %Hb, p = 0.002). (2) A 10-s longer maximal breath-hold duration raised odds of the primary outcome 2.7-fold (log-odds = 0.10 ± 0.05 per sec, p = 0.037). Note these odds are adjusted for baseline SpO2 and other covariates. However, the ventilatory response variable was not associated with the primary outcome. Significance was not altered by exploratory inclusion of additional available covariates to the reference model (e.g. C-reactive protein, d-dimer, hemoglobin) or omission of existing covariates (Additional file 1).
Table 2.
Primary model β ± SEM (p value) |
Parsimonious model β ± SEM (p value) |
|
---|---|---|
Breath-holding measurements | ||
Mean desaturation (%Hb) |
1.27 ± 0.59 (0.002) |
1.25 ± 0.54 (0.001) |
Maximal breath-hold duration (s) |
0.10 ± 0.05 (0.037) |
0.10 ± 0.05 (0.020) |
Ventilatory response (%baseline) |
0.00 ± 0.01 (0.9) |
— |
Covariates | ||
Body mass index (kg/m2) |
0.22 ± 0.22 (0.3) |
0.27 ± 0.19 (0.157) |
Baseline SpO2 (%) |
− 0.44 ± 0.22 (0.001) |
-0.45 ± 0.22 (0.001) |
Cardiovascular disease |
4.47 ± 2.71 (0.064) |
5.27 ± 2.38 (0.019) |
Association between breath-holding measurements at admission and the adverse composite primary outcome in COVID-19 (multivariable logistic regression). Data shown are β ± SEM (p value); β describes the increase in log-odds of the adverse outcome per change in exposure variable. Primary model: The breath-holding measurements significantly improved the model (likelihood ratio 0.0073, p = 0.02) over a reference model with covariates only (body mass index, baseline SpO2, cardiovascular disease [1 = Present, 0 = Absent], plus age and sex [not shown]). p values are based on likelihood ratio tests. The parsimonious model is a simplified and refined version of the primary model (age, sex, and ventilatory response were removed [p > 0.2]; Intercept = 25.31 ± 17.31). The potential predictive value of the model is illustrated in Fig. 2D and a tool for risk calculation is provided in Additional file 2
Sensitivity analysis
Greater mean desaturation raised the odds of the adverse composite outcome in simple bivariate analysis (log-odds of VS +: 0.67 ± 0.23 per %Hb, p = 0.0007), when additionally adjusted for aforementioned covariates including baseline SpO2 (0.65 ± 0.33, p = 0.023), and with further adjustment for maximal breath-hold duration (1.26 ± 0.56, p = 0.002). By contrast, maximal breath-hold duration was only associated with the primary outcome with (but not without) the appropriate adjustment for mean desaturation (Table 2).
Group differences
In adjusted analysis, VS + patients (N = 11) exhibited greater mean desaturation v. VS − patients (N = 39; difference[95%CI] 1.6[0.3–2.8]%Hb, p = 0.009) and controls (N = 23; 2.3[0.8–3.9]%Hb, p = 0.002; Fig. 2A); differences were clear despite adjustment for the lower baseline SpO2 seen in VS + (versus VS −: 5.8[3.5–8.0] %Hb, versus controls: 7.5[4.7–10.3]%Hb, p < 0.0001, see Fig. 1B). VS − patients, but not VS + patients, had shorter adjusted maximal breath-hold duration than controls (difference = 15.9[5.6–26.1] s, p = 0.002, Fig. 2C).
Potential for outcome discrimination in COVID-19
The parsimonious model (Table 2) describing risks associated with mean desaturation and maximal breath-hold duration exhibited discriminative potential (Fig. 2D-left): model accuracy was 94[88–100]% (p < 0.0001 v. chance), which was significantly superior (random permutation analysis, p = 0.007) to a reference model (covariates only; includes baseline SpO2) without breath-holding measurements (reference accuracy = 80[69–91]%, Fig. 2D-right). The breath-holding model—but not the reference model—passed cross validation analysis (accuracy 80[69–91]%, p = 0.003; reference model accuracy 70[57–83]%, p = 0.24).
Relationship to dyspnea
Given associations between adverse outcomes and greater breath-holding tolerance (maximal breath-hold duration) we performed additional analysis of dyspnea at admission: In fully adjusted analysis, dyspnea (Borg 1–3 v. Borg = 0) was also associated with reduced risk of the primary outcome in COVID-19 in the current sample ([log-odds: − 2.8 ± 1.6, p = 0.038). Inclusion of dyspnea in the above models did not meaningfully alter the findings reported above (see Additional file 1).
Discussion
Our prospective observational study demonstrated that adverse outcomes of COVID-19 (composite outcome of non-invasive ventilation, intensive care admission, or death) are associated with deficits in gas exchange and ventilatory control revealed using a validated breath-holding technique. Specifically, we demonstrated that with increasing predisposition to oxygen desaturation during breath-holding there is higher risk of progression to severe disease, independent of baseline oxygenation, and other key covariates. Greater maximal breath-hold duration—adjusted for hypoxemia (i.e. baseline saturation)—was also an independent risk factor among patients with COVID-19. Our finding that blunted ventilatory control [26–28] is a deleterious physiological feature of COVID-19 does not support the notion that vigorous ventilatory drive promotes self-inflicted lung injury (P-SILI) [31–33], but rather is consistent with “silent hypoxemia” as a prevalent characteristic in COVID-19 [13–15, 34, 35]. A third breath-holding variable, the ventilatory response to 20-s breath holds, was not associated with the primary outcome. Each analysis demonstrated that associations between breath-holding variables and the adverse outcomes (as well as outcome prediction) were seen above and beyond baseline saturation (and other commonly-available clinical measures). Overall, the current study provides unique insight into the differential physiological characteristics of patients who exhibit adverse outcomes v. those who do not. We consider that this knowledge has the potential to be used in future tools to identify patients at elevated risk of adverse outcomes in COVID-19.
Novel physiological insights
Desaturation
Early signs of gas exchange deficits in patients who later develop severe COVID-19—such as regional ventilation/perfusion (V/Q) heterogeneity and reduced lung gas volumes—have been inferred from chest imaging [5, 14, 15]; however, functional evidence of this notion is limited. Here, we show that breath-holding unmasks a greater COVID-19-related decline in gas exchange in those who progress to severe disease versus those who do not. Specifically, after adjusting for baseline SpO2, breath-holding desaturation is an independent risk factor for adverse outcomes in COVID-19. Indeed, breath-holding is expected to provide unique information on gas exchange deficits on the basis that V/Q heterogeneity (lower V/Q regions readily desaturate during apnea) [16] and reduced lung gas volumes (greater decline in alveolar PO2 per unit time) [17, 18] influence desaturation speed independently of baseline SpO2. Of note, baseline SpO2 can be insensitive to reduced PaO2 when on the plateau of the SpO2/PaO2 curve. Our findings also withstood adjustment for obesity and pre-existing cardiovascular disease as confounders, suggesting that these particular non-COVID sources of variability do not explain away the associations observed.
Ventilatory control
The finding that longer maximal breath-hold duration (SpO2-adjusted [30]) confers risk in COVID-19 suggests that blunted ventilatory control responses [26–28] may precede severe versus milder disease. Supporting this notion, absence of dyspnea (Borg = 0) was also an independent risk factor for adverse outcomes in the current study (n.b. impaired chemosensitivity may mitigate dyspnea [36–40]). Notably, COVID-19 is associated with anosmia/dysgeusia, and investigators have previously speculated infection at the carotid bodies [21] or centrally [34]. Regardless, it is unclear whether ventilatory control effects of COVID-19 are causally involved in respiratory failure or simply a marker of more severe viral illness. Indeed, interventional studies using ventilatory stimulants could shed light on the putative causal pathways. We also observed that patients who did not develop severe disease had shorter breath-hold durations v. healthy controls; thus, such individuals may escape adverse outcomes of COVID-19 partly through a more robust ventilatory control defense against hypoxia/hypercapnia. Overall, our data do not support the concept that robust chemoreflexes exacerbate lung injury via greater chemoreflex-related transpulmonary pressures (P-SILI) [23, 24]. Instead, our study suggests that blunted ventilatory control in the face of hypoxemia (i.e. “silent hypoxemia”) is additionally deleterious in COVID-19 [19, 20, 22, 34, 35]. Nonetheless, our findings suggest that breath-holding duration may be a clinically important biomarker for identifying risk of subsequent respiratory failure regardless of the underlying mechanisms.
Clinical implications
Understanding risk factors for adverse outcomes of COVID-19 has been the focus of intense research over the last 12 months. To date, notable studies examining risk factors have been retrospective in design [2, 4–9, 14]. In the current prospective study, greater breath-holding desaturation and reduced maximal breath-holding duration were associated with adverse outcomes in COVID-19 independently of baseline SpO2, and early analysis suggests that the approach has potential predictive value. Exploratory inclusion of existing biomarkers C-reactive problem and d-dimer, and adjustments for haemoglobin levels did not change our findings. Our translational work therefore demonstrates the feasibility of using physiological testing to estimate the risk of adverse COVID-19 outcomes days in advance of patient deterioration, enabling prioritization of limited resources to the high risk patients who need them most (Fig. 2D), and providing a window for early administration of medical therapies (e.g. dexamethasone) prior to advanced disease progression, especially in pandemic epicenters (an excel prognostic tool is also provided for academic evaluation). These findings are consistent with anecdotal reports of clinicians in Italy and beyond successfully using exertional test-derived altered SpO2 values to triage patients with Covid-19 and hospitalization those with post-exertional greater desaturation [10–12]. However, in contrast to exertional tests (i.e. 6-min walking test), breath-holding does not require increased energy expenditure or cardiac output, and obviates walking and associated bystander/caregiver contamination. Measurement of these simple, novel surrogates capturing pulmonary and chemoreflex risk factors requires minimal inventory (i.e. a means to record oximetry and a timing device) and could feasibly provide a useful means to estimate risks of future deterioration in under-resourced circumstances, should future validation studies support this concept.
Methodological considerations
This study has several limitations. First, while the sample size provided sufficient power to confirm our primary hypothesis (see Additional file 1: Statistical Analysis), we did not have an additional sample for an independent validation analysis (study is forthcoming). However, random permutation analysis and leave-one-out cross validation provided rigor and reassurance that results were not the trivial consequence of overfitting. Second, the number of covariates (potential confounders) included in our model analyses may raise concerns, yet we emphasize that simulations demonstrated that statistical power was not meaningfully reduced by the inclusion of uncorrelated covariates and that the inclusion or removal of covariates did not strength or weaken the associations. Third, given the narrow race/ethnicity of our study population, we cannot generalize our findings to all potential patient populations globally. In addition, our analysis suggests that breath-holding variables are associated with adverse outcomes independent of sex, but we are unable to conclude whether breath-holding variables are associated with adverse outcomes specifically within men or within women, or if sex-specific models might be needed. A larger study of women and men is needed to address these questions. Fourth, breath-holding required cooperation so patients who necessitated immediate ventilatory support were not studied. Nevertheless, we highlight that people requiring urgent intervention are, by definition, readily triaged and beyond the scope of this work. Fifth, the maximal breath-hold variable, but not the ventilatory response variable, suggested increased chemosensitivity was protective. We emphasize, however, that measurement of the ventilatory response was more complex (requires assumptions of nasal breathing and effective linearization of nasal pressure). Of note, the ventilatory response variable is susceptible to measurement noise in the absence of a sealed oronasal mask and pneumotachometer [26] and thus potentially unreliable. Despite these limitations, we believe our findings are clinically important and deserve further study.
Conclusions
Breath-holding measurements of susceptibility to rapid desaturation and ventilatory control sensitivity are associated with progression to respiratory failure in COVID-19: greater desaturation during breath-holds (interpreted as greater gas exchange deficit) and longer maximal breath-holds (interpreted as lower chemosensitivity) are independent risk factors. Simplified physiological measures of gas exchange and neurophysiological deficits in COVID-19 may hold utility for future translational use in early triage to scarce health care resources or early administration of medical interventions. Our study also raises the possibility that blunted ventilatory control is a therapeutic target for preventing severe disease in COVID-19, a concept that will require interventional studies to assess.
Supplementary Information
Acknowledgements
We are sincerely thankful to all the Italian sleep technicians that worked on this project, especially Valeria Di Stefano, Francesca Gregorini and Anna Motta, for their essential contribution to data collection.
Authors' contributions
Study design: LM, SS. Data collection: EP, LC, SJ, FF, LP, CL, GV. Data analysis: LM, SS. Interpretation of results: All authors. Drafting of the manuscript: LM, AM, SS. Editing of the manuscript for important intellectual content: All authors.
Funding
This study was not directly funded. LM is supported by Flinders University. SJ is supported by an NHMRC Early Career Fellowship (1139745). FF is supported by the “Ricerca Corrente” funding of ICS Maugeri Spa SB. AM is supported by NIH. SS is supported by the NIH NHLBI (R01HL146697).
Availability of data and materials
All the individual participant and summary data collected during the trial will be shared upon request, after de-identification. Additionally, study protocol, statistical analysis plan and informed consent will be made available. Data will be available immediately following publication and ending 5 years following article publication with researchers who provide a methodologically sound proposal to achieve aims in such approved proposal. Proposals should be directed to LM ludovico.messineo@yahoo.it or EP e.perger@auxologico.it; access will require a data use agreement.
Declarations
Ethics approval
This study was approved by the Italian Auxologico Institute Ethics Committee (number: 2020_04_03_03) on April 3rd, 2020, which was the reference center for recruitment of COVID-19 patients, and by the Monash Health HREC (number: RES-20-0000-264A) on April 29th, 2020, which was the main reference for recruitment of healthy individuals. The study was also approved by the Brescia local Ethics Committee (number: 4068) on April 17th, 2020 and Pavia local Ethics Committee (number: 2412) on April 20th, 2020. All participants provided verbal or written informed consent upon enrolment (the study was exempted from written consent in some centers to limit the spread of the infection). The study conformed to the standards set by the latest revision of the Declaration of Helsinki. This study also adhered to both STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) and TRIPOD (Transparent Reporting of a multivariable prediction model for Individual Prognosis or Diagnosis) reporting guidelines.
Consent for publication
NA.
Competing interests
AW works as a consultant for Apnimed, Nox, Inspire, and Somnifix. He has received grants from Sanofi and Somnifix. He also has a financial interest in Apnimed Corp., a company developing pharmacologic therapies for sleep apnea. AW interests were reviewed and are managed by Brigham and Women’s Hospital and Partners HealthCare in accordance with their conflict of interest policies. SS reports grants and personal fees from Apnimed, personal fees from Nox Medical, personal fees from Merck, personal fees from Inspire, grants from Prosomnus, grants from Dynaflex, outside the submitted work. In addition, SS has a patent pending related to wearable oximetry technology for sleep apnea diagnosis/phenotyping, unrelated to breath-holding. GH reports non-financial support from Resmed, non-financial support from Philips Respironics, non-financial support from Air Liquide Healthcare, outside the submitted work. AM reports income related to medical education from Merck and Livanova; ResMed provided a philanthropic donation to UC San Diego. LM, EP, LC SJ, FF, LP, PT, CL, GV, GP have no conflicts of interest to disclose.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Ludovico Messineo and Elisa Perger have equaly contributed to this work
References
- 1.Rosenbaum L. Facing Covid-19 in Italy - Ethics, Logistics, and Therapeutics on the Epidemic's Front Line. N Engl J Med. 2020. [DOI] [PubMed]
- 2.Zhou F, Yu T, Du R, Fan G, Liu Y, Liu Z, et al. Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study. Lancet. 2020;395(10229):1054–1062. doi: 10.1016/S0140-6736(20)30566-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.WHO. Clinical management of severe acute respiratory infection when novel coronavirus (nCoV) infection is suspected; interim guidance, May 27th. 2020 [cited 2020 July, 7th]; https://apps.who.int/iris/bitstream/handle/10665/332196/WHO-2019-nCoV-clinical-2020.5-eng.pdf?sequence=1&isAllowed=y.
- 4.Bello-Chavolla OY, Bahena-Lopez JP, Antonio-Villa NE, Vargas-Vazquez A, Gonzalez-Diaz A, Marquez-Salinas A et al. Predicting mortality due to SARS-CoV-2: a mechanistic score relating obesity and diabetes to COVID-19 outcomes in Mexico. J Clin Endocrin Metab. 2020;105(8). [DOI] [PMC free article] [PubMed]
- 5.Angeli E, Dalto S, Marchese S, Setti L, Bonacina M, Galli F, et al. Prognostic value of CT integrated with clinical and laboratory data during the first peak of the COVID-19 pandemic in Northern Italy: a nomogram to predict unfavorable outcome. Eur J Radiol. 2021;137:109612. doi: 10.1016/j.ejrad.2021.109612. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Ruan Q, Yang K, Wang W, Jiang L, Song J. Clinical predictors of mortality due to COVID-19 based on an analysis of data of 150 patients from Wuhan. China Intensive Care Med. 2020;46(5):846–848. doi: 10.1007/s00134-020-05991-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Xie J, Hungerford D, Chen H, Abrams ST, Li S, Wang G, et al. Development and external validation of a prognostic multivariable model on admission for hospitalized patients with COVID-19. medRxiv. 2020.
- 8.Shi Y, Yu X, Zhao H, Wang H, Zhao R, Sheng J. Host susceptibility to severe COVID-19 and establishment of a host risk score: findings of 487 cases outside Wuhan. Crit Care. 2020;24(1):108. doi: 10.1186/s13054-020-2833-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Sun H, Jain A, Leone MJ, Alabsi HS, Brenner LN, Ye E, et al. COVID-19 outpatient screening: a prediction score for adverse events. medRxiv. 2020.
- 10.Paglia S, Storti E, Magnacavallo A, Cianci V, Cibinel GA, Fabbri A, et al. Rapporto Prima Linea Covid-19 assetto organizzativo gestionale dei PS/DEA nell’ambito di focolaio epidemico o pre-epidemico. 2020 [cited 2020 July, 14th]; http://www.quotidianosanita.it/allegati/allegato3277121.pdf.
- 11.Bertolini G, Nattino G. Pazienti COVID-19: la cura inizia a casa. Un progetto di monitoraggio attivo a Casale Monferrato e Torino 2020 [cited 2020 July, 7th]; http://www.fondazionebuzziunicem.org/documents/459904/466757/COVID-lacurainziaacasa.pdf/66404644-6828-110a-8129-cd9cefadf581.
- 12.Greenhalgh T, Javid B, Knight M, Inada-Kim M. What is the efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19? : Oxford Covid-19 evidence service; 2020; https://www.researchgate.net/publication/340934179_What_is_the_efficacy_and_safety_of_rapid_exercise_tests_for_exertional_desaturation_in_covid-19. [DOI] [PMC free article] [PubMed]
- 13.Goodacre S, Thomas B, Lee E, Sutton L, Loban A, Waterhouse S et al. Post-exertion oxygen saturation as a prognostic factor for adverse outcome in patients attending the emergency department with suspected COVID-19: a substudy of the PRIEST observational cohort study. Emerg Med J. 2020. [DOI] [PMC free article] [PubMed]
- 14.Wang S, Zha Y, Li W, Wu Q, Li X, Niu M, et al. A fully automatic deep learning system for COVID-19 diagnostic and prognostic analysis. Eur Respir J. 2020;56(2). [DOI] [PMC free article] [PubMed]
- 15.Bernheim A, Mei X, Huang M, Yang Y, Fayad ZA, Zhang N, et al. Chest CT findings in coronavirus disease-19 (COVID-19): relationship to duration of infection. Radiology. 2020;295(3):200463. doi: 10.1148/radiol.2020200463. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Sands SA, Edwards BA, Kelly VJ, Davidson MR, Wilkinson MH, Berger PJ. A model investigation of the impact of ventilation-perfusion mismatch on oxygenation during apnea in preterm infants. J Theor Biol. 2010 doi: 10.1016/j.jtbi.2010.03.041. [DOI] [PubMed] [Google Scholar]
- 17.Sands SA, Edwards BA, Kelly VJ, Davidson MR, Wilkinson MH, Berger PJ. A model analysis of arterial oxygen desaturation during apnea in preterm infants. PLoS Comput Biol. 2009;5(12):e1000588. doi: 10.1371/journal.pcbi.1000588. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Findley LJ, Ries AL, Tisi GM, Wagner PD. Hypoxemia during apnea in normal subjects: mechanisms and impact of lung volume. J Appl Physiol. 1983;55(6):1777–1783. doi: 10.1152/jappl.1983.55.6.1777. [DOI] [PubMed] [Google Scholar]
- 19.Couzin-Frankel J. The mystery of the pandemic's 'happy hypoxia'. Science. 2020;368(6490):455–456. doi: 10.1126/science.368.6490.455. [DOI] [PubMed] [Google Scholar]
- 20.Widysanto A, Wahyuni TD, Simanjuntak LH, Sunarso S, Siahaan SS, Haryanto H, et al. Happy hypoxia in critical COVID-19 patient: a case report in Tangerang, Indonesia. Physiol Rep. 2020;8(20):e14619. doi: 10.14814/phy2.14619. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Villadiego J, Ramírez-Lorca R, Cala F, Labandeira-García JL, Esteban M, Toledo-Aral JJ, et al. Is Carotid body infection responsible for silent hypoxemia in COVID-19 patients? Function. 2020;2(1). [DOI] [PMC free article] [PubMed]
- 22.Tobin MJ, Laghi F, Jubran A. Why COVID-19 silent hypoxemia is baffling to physicians. Am J Respir Crit Care Med. 2020 [DOI] [PMC free article] [PubMed]
- 23.Gattinoni L, Marini JJ, Camporota L, et al. Reply to Tobin, Respiratory drive measurements do not signify conjectural patient self-inflicted lung injury. Am J Respir Crit Care Med. 2021;203(1):143–144. doi: 10.1164/rccm.202009-3692LE. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Marini JJ, Gattinoni L. Management of COVID-19 respiratory distress. JAMA. 2020;323(22):2329–2330. doi: 10.1001/jama.2020.6825. [DOI] [PubMed] [Google Scholar]
- 25.Tobin MJ, Jubran A, Laghi F. Respiratory drive measurements do not signify conjectural patient self-inflicted lung injury. Am J Respir Crit Care Med. 2021;203(1):142–143. doi: 10.1164/rccm.202009-3630LE. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Messineo L, Taranto-Montemurro L, Azarbarzin A, Oliveira Marques MD, Calianese N, White DP, et al. Breath-holding as a means to estimate the loop gain contribution to obstructive sleep apnoea. J Physiol. 2018;596(17):4043–4056. doi: 10.1113/JP276206. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Stanley NN, Cunningham EL, Altose MD, Kelsen SG, Levinson RS, Cherniack NS. Evaluation of breath holding in hypercapnia as a simple clinical test of respiratory chemosensitivity. Thorax. 1975;30(3):337–343. doi: 10.1136/thx.30.3.337. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Trembach N, Zabolotskikh I. Breath-holding test in evaluation of peripheral chemoreflex sensitivity in healthy subjects. Respir Physiol Neurobiol. 2017;235:79–82. doi: 10.1016/j.resp.2016.10.005. [DOI] [PubMed] [Google Scholar]
- 29.Duca A, Piva S, Foca E, Latronico N, Rizzi M. Calculated Decisions: Brescia-COVID respiratory severity scale (BCRSS)/algorithm. Emerg Med Pract. 2020;22(5 Suppl):CD1–CD2. [PubMed] [Google Scholar]
- 30.Bruce CD, Vanden Berg ER, Pfoh JR, Steinback CD, Day TA. Prior oxygenation, but not chemoreflex responsiveness, determines breath-hold duration during voluntary apnea. Physiol Rep. 2021;9(1):e14664. doi: 10.14814/phy2.14664. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Marini JJ, Gattinoni L. Management of COVID-19 respiratory distress. JAMA. 2020. [DOI] [PubMed]
- 32.Mascheroni D, Kolobow T, Fumagalli R, Moretti MP, Chen V, Buckhold D. Acute respiratory failure following pharmacologically induced hyperventilation: an experimental animal study. Intensive Care Med. 1988;15(1):8–14. doi: 10.1007/BF00255628. [DOI] [PubMed] [Google Scholar]
- 33.Esnault P, Cardinale M, Hraiech S, Goutorbe P, Baumstrack K, Prud'homme E, et al. High respiratory drive and excessive respiratory efforts predict relapse of respiratory failure in critically Ill patients with COVID-19. Am J Respir Crit Care Med. 2020. [DOI] [PMC free article] [PubMed]
- 34.Swenson KE, Ruoss SJ, Swenson ER. The pathophysiology and dangers of silent hypoxemia in COVID-19 lung injury. Ann Am Thoracic Soc. 2021. [DOI] [PMC free article] [PubMed]
- 35.Simonson TS, Baker TL, Banzett RB, Bishop T, Dempsey JA, Feldman JL, et al. Silent hypoxaemia in COVID-19 patients. J Physiol. 2021;599(4):1057–1065. doi: 10.1113/JP280769. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Davidson JT, Whipp BJ, Wasserman K, Koyal SN, Lugliani R. Role of the carotid bodies in breath-holding. N Engl J Med. 1974;290(15):819–822. doi: 10.1056/NEJM197404112901502. [DOI] [PubMed] [Google Scholar]
- 37.Paton JY, Swaminathan S, Sargent CW, Keens TG. Hypoxic and hypercapnic ventilatory responses in awake children with congenital central hypoventilation syndrome. Am Rev Respir Dis. 1989;140(2):368–372. doi: 10.1164/ajrccm/140.2.368. [DOI] [PubMed] [Google Scholar]
- 38.Gigliotti F. Mechanisms of dyspnea in healthy subjects. Multidiscip Respir Med. 2010;5(3):195–201. doi: 10.1186/2049-6958-5-3-195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Kikuchi Y, Okabe S, Tamura G, Hida W, Homma M, Shirato K, et al. Chemosensitivity and perception of dyspnea in patients with a history of near-fatal asthma. N Engl J Med. 1994;330(19):1329–1334. doi: 10.1056/NEJM199405123301901. [DOI] [PubMed] [Google Scholar]
- 40.Molfino NA, Nannini LJ, Martelli AN, Slutsky AS. Respiratory arrest in near-fatal asthma. N Engl J Med. 1991;324(5):285–288. doi: 10.1056/NEJM199101313240502. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All the individual participant and summary data collected during the trial will be shared upon request, after de-identification. Additionally, study protocol, statistical analysis plan and informed consent will be made available. Data will be available immediately following publication and ending 5 years following article publication with researchers who provide a methodologically sound proposal to achieve aims in such approved proposal. Proposals should be directed to LM ludovico.messineo@yahoo.it or EP e.perger@auxologico.it; access will require a data use agreement.