Skip to main content
PLOS ONE logoLink to PLOS ONE
. 2021 Jun 17;16(6):e0252950. doi: 10.1371/journal.pone.0252950

Mouse lung automated segmentation tool for quantifying lung tumors after micro-computed tomography

Mary Katherine Montgomery 1,#, John David 1,#, Haikuo Zhang 2, Sripad Ram 3, Shibing Deng 4, Vidya Premkumar 1, Lisa Manzuk 1, Ziyue Karen Jiang 1, Anand Giddabasappa 1,*
Editor: Joseph Najbauer5
PMCID: PMC8211241  PMID: 34138905

Abstract

Unlike the majority of cancers, survival for lung cancer has not shown much improvement since the early 1970s and survival rates remain low. Genetically engineered mice tumor models are of high translational relevance as we can generate tissue specific mutations which are observed in lung cancer patients. Since these tumors cannot be detected and quantified by traditional methods, we use micro-computed tomography imaging for longitudinal evaluation and to measure response to therapy. Conventionally, we analyze microCT images of lung cancer via a manual segmentation. Manual segmentation is time-consuming and sensitive to intra- and inter-analyst variation. To overcome the limitations of manual segmentation, we set out to develop a fully-automated alternative, the Mouse Lung Automated Segmentation Tool (MLAST). MLAST locates the thoracic region of interest, thresholds and categorizes the lung field into three tissue categories: soft tissue, intermediate, and lung. An increase in the tumor burden was measured by a decrease in lung volume with a simultaneous increase in soft and intermediate tissue quantities. MLAST segmentation was validated against three methods: manual scoring, manual segmentation, and histology. MLAST was applied in an efficacy trial using a Kras/Lkb1 non-small cell lung cancer model and demonstrated adequate precision and sensitivity in quantifying tumor growth inhibition after drug treatment. Implementation of MLAST has considerably accelerated the microCT data analysis, allowing for larger study sizes and mid-study readouts. This study illustrates how automated image analysis tools for large datasets can be used in preclinical imaging to deliver high throughput and quantitative results.

Introduction

Lung cancer is the leading cause of cancer deaths worldwide. Each year, 2.1 million people are diagnosed with the disease and 1.8 million die from it [1]. Lung cancer is broadly classified as non-small cell lung cancer (NSCLC), the most prevalent form which makes up 85% of the patients, or small cell lung cancer (SCLC), which accounts for the remaining 15% of lung cancer patients [1]. There has been tremendous progress in the treatment of lung cancer with targeted therapies in the last two decades [2] and very recently with immuno-oncology agents [3].

Lung tumors are driven by mutations in oncogenic or tumor suppressor genes resulting in gain or loss of function, respectively [46]. The most common oncogenes that carry driver mutations include EGFR, Kras, ALK and tumor suppressors p53 and RB1. Discovery of these driver mutations has led to novel targeted therapies which have shown significant promise in selected patients [7]. Genetically engineered mouse (GEM) models of lung cancer have played important roles in understanding the driver mutations and disease pathology as well as in assessment of novel drug candidates prior to clinical evaluation [8, 9].

Unlike traditional subcutaneous xenograft models, GEM lung tumor models present a unique challenge because tumors spontaneously develop within the lungs just as they do in patients. Quantifying treatment effects in these internal tumors requires imaging as they cannot be measured with calipers antemortem. Computed tomography (CT) imaging is used clinically for standard assessment and grading based on Response Evaluation Criteria in Solid Tumors (RECIST) criteria [10]. Advances in micro-computed tomography (microCT) imaging technology have led to its use in evaluating lung GEM models non-invasively [11, 12].

Previously we demonstrated proof of concept in using microCT technology to evaluate the efficacy of targeted therapies in NSCLC GEM models [13]. There have been multiple efforts by other teams to evaluate lung tumors in mice [14, 15]. Traditional methods of manual analysis generally include qualitative assessment where a radiologist or researcher would assign an ordinal score on a system similar to those utilized in pathology [16], or quantitative analysis via manual segmentation of lung tumors with software tools such as “paint” or “lasso” (VivoQuant™, Invicro, Boston, MA) ideally with costly contrast-enhancement [12, 13]. In a 3D lung scan, this process is time consuming and prohibits interim reads of large studies. In addition, the results can introduce intra/inter-analyst variability. To address these challenges, we developed the mouse lung automated segmentation tool (MLAST). MLAST automatically segments lung-field microCT scans into tissue types by density and allows for quantitative tracking of lung air volume throughout disease progression in a variety of murine lung tumor models. MLAST has been validated against manual scoring, manual segmentation, and histology, and has demonstrated an ability to accurately characterize loss of lung space in diseased animals.

Methods

Animal model

All animal procedures were performed as described in the animal use protocols approved by Pfizer’s Institutional Animal Care and Use Committee. The non-small cell lung cancer GEM mice KP (KrasG12D-LSL/+/p53fl/fl) and KL (KrasG12D-LSL/+/Lkb1fl/fl: B6.Lkb1-B6.129S4-Krastm4Tyj/J) were purchased from Jackson Laboratories (Bar harbor, ME). Lung tumors were induced as previously described by DuPage M et al., 2009 [17]. Briefly, 8–12 weeks old KP or KL mice were induced with 1 × 106 PFU adeno-virus (Ad5CMVCre, University of Iowa) intranasally under 3% isoflurane anesthesia. Health checks of the animals were performed weekly. After six weeks post-virus delivery, microCT imaging was initiated to evaluate the lung tumor burden. During every imaging session the animals were anesthetized with 1.5 to 3% of isoflurane and maintained under isoflurane anesthesia throughout the imaging session. Since the animals had tumors internally (in lungs) they were euthanized at the end of the study or based on the body condition scoring method [18], per the Pfizer IACUC’s guidelines. Euthanasia was performed by CO2 inhalation and cervical dislocation as a secondary method. When lungs were collected for immunohistochemistry, the animals were euthanized by CO2 and inflated with formalin. The radiation dose was <1 μSv per scan, which is several orders of magnitude less than a therapeutic dose [19]. Radiation exposure from the scans was therefore deemed to have no impact on the observations of this study.

To validate non-contrast segmentation of lung tumors with MLAST, KL tumor bearing mice (n = 10) were longitudinally imaged twice at 4 time-points, once pre-induction, and at weeks 4, 8, and 12 post-induction. The first scan was non-contrast followed by a contrast-enhanced scan.

For contrast-enhanced imaging, animals were injected IV with 100 μl of Viscover ExiTron Nano 12,000, an inorganic iodine nanoparticulate (Miltenyi Biotec, Bergisch-Gladbach, Germany), and were imaged 15 minutes post-injection using parameters described previously [13]. MLAST was used to segment all non-contrast scans. Manual segmentation was performed first on the non-contrast scans and then on the contrast scans by a single analyst who was blinded to time-point and scan pairing. The volumes segmented from the non-contrast scans by both manual segmentation and MLAST were compared to the volumes manually segmented from the contrast-enhanced scans by calculating the Pearson’s correlation coefficient. The non-contrast lung segmentations were also compared with a Sorenson-Dice coefficient, as is commonly used in image segmentation validation efforts [20].

MLAST was utilized to evaluate efficacy of a drug in a KL-GEM model of lung cancer. Non-contrast microCT imaging was performed biweekly after 6 weeks post-virus induction until tumors reached an advanced score between 2 to 2.5. Animals were dosed with the drug via oral route for 21 days. The pretreatment scans were compared with post-treatment images by manual scoring and MLAST, as described below.

microCT acquisition

Images were acquired with a SkyScan 1278 (Bruker Corporation, Billerica, MA) using a 0.5 cm Al filter at 918 μA, 50 kV, 100 μm resolution, and a step size of 0.5° per projection for 360° with scan time of ~2 minutes. Images were Feldkamp reconstructed with an isotropic 100 μm voxel, ring artifact correction, a 12% beam hardening correction, Gaussian smoothing with a kernel size of 2, and a pixel matrix of approximately 230 × 310 × 185 (NRecon 1.7.1.0, Bruker, Billerica, MA).

microCT data analysis

microCT scans were evaluated by three different methods: manual scoring, manual segmentation and automated analysis using MLAST. Manual scoring was performed by a blinded scientist using Amira 6.3 image analysis software (ThermoFisher Scientific, Waltham, MA). Scientists viewed scans in 3D using different orientations to look for tumor nodules, and assigned each scan a score on a 0–3 ordinal scale. A score of 0 indicated a scan with no visible tumors. A score of 1 was assigned to a scan with one or two small tumor nodules. A score of 2 indicated a scan with mid-size to large tumors that were beginning to fuse together. Finally, a score of 3 was assigned to any scan in which a large coalescing mass of tumor occupied more than half the lung space (Fig 1).

Fig 1. Representative images showing manual qualitative scores.

Fig 1

A score of 0 contains no signs of tumor mass. The contrast in the lung space is derived from blood vessels and heart tissue. A score of 1 shows one or two small nodules within the lung field. A score of 2 shows more nodules that are beginning to coalesce, and a score of 3 shows a large coalescing mass that has infiltrated more than half the lung space.

Manual segmentation was also performed by blinded scientists using Amira 6.3 software with the “paint” tool and interpolation every two slices to classify the lungs, heart, and tumors in the scan. Vasculature was not separately classified due to the inability to segment tumor from vessels in non-contrast microCT scans. The caudal bound was set at the diaphragm and was excluded from segmentation. The cranial bound was set at the tracheal bifurcation. The average number of slices was 93.0 +/- 1.50.

Automated analysis using MLAST

The MLAST algorithm was written in Matlab R2017b, and utilized the Image Processing, Statistics and Machine Learning, and Parallel Computing toolboxes. The algorithm estimated the outer limits of the thoracic cavity and automatically separated the voxels into different tissue types based on density: soft tissue, lung, and intermediate. The soft tissue is inclusive of tumors, esophagus, heart, and vasculature; these tissues are binned together due the similar density on microCT. The intermediate classification is one of lower density on the microCT and represents a mix of motion artifacts of respiration in small nodules and non-solids lesions with either an acinar or ground-glass appearances [21]. The non-diseased lung segmentation was then expressed as a percentage of the total thoracic cavity and tracked over longitudinal scans for a given animal. The non-diseased lung area had significant decreases in the percentage due to space occupying lesions. The specific steps are demonstrated in Fig 2 and described in detail below.

Fig 2. Schematic of MLAST analysis.

Fig 2

(A) Depiction of MLAST’s segmentation algorithm. The original microCT 2D image contains the densities of various tissues observed in a thoracic scan. The ribcage provides a high contrast for thresholding. The interior points of the rib regions are used to create a mask of the thoracic cavity. The densities of the voxels within the masked image are segmented with a k-means clustering algorithm and the intensities are classified into 3 tissue types: soft tissue (green), lung (blue), and intermediate (cyan). The final segmented result is shown in 2D and applied to all slices in the z-stack. (B) Depiction of how MLAST detects the cranial and caudal boundaries of the thoracic cavity. The cranial boundary is determined by the bifurcation of the trachea. Below the bifurcation, the two tracheal regions (colored blue and shown in inset) are separate. Tissues above the bifurcation, where the two regions are no longer separable, are excluded from the final segmentation. On the caudal end, the diaphragm is segmented based on density changes in the z-trace of each voxel. The resulting diaphragm (red) is removed from the thoracic counts of soft tissue, lung, and intermediate.

First, the thoracic cavity was identified using the ribcage in a similar approach to that described in Barck et al., 2015 [14]. Scans were thresholded to identify high-density bone and the largest connected 3D object was identified. Three slices were stacked to smooth the transition between slices (an improvement on Barck et al.’s method), and the bones were used to create a mask outline of the thoracic cavity. In each 2D axial slice, groups of connected bone pixels were identified as individual ribs or spine, and the innermost points of these bones were reordered clockwise by the angle between their centroids and the centroid of the entire ribcage (Fig 2A). A spline function was then used to interpolate between these points, producing a rough outline of the interior of the ribcage, and therefore the exterior of the thoracic cavity. To improve MLAST performance in scans with minor motion artifact, two iterations of this approach were included. In the first, all points in the outlines of the rib regions were used to draw the initial mask of the thoracic cavity. The interior of this mask was then used as the centroid for the next iteration of the approach, in which only the innermost 30% of the rib points were used to draw the outline of the new mask. This approach ensured a more stable mask and helped to prevent the accidental inclusion of the intercostal muscles in the mask of the thoracic cavity.

Next, the data was automatically segmented using a one-dimensional implementation of the unsupervised machine learning algorithm k-means clustering (MathWorks, Natick, MA), which broke voxels into clusters according to density. The k-means algorithm used a k++ seeding to set initial cluster centroids at 3 different locations on the spectrum of densities seen in the image. Voxels were assigned to the cluster with the nearest centroid, and then the centroids were updated to the center of all densities assigned to the cluster. This process was repeated until either the cluster assignments stopped changing or the maximum number of iterations (100) was reached. The cluster with the lowest-density centroid was assigned to lung, the cluster with the highest-density centroid was classified as soft tissue, and the middle cluster was declared intermediate (Fig 2A).

Finally, the cranial and caudal cutoffs were determined as demonstrated in Fig 2B. Similar to the method described in [14], the z-slice where the tracheal region split in two was used as the cranial cutoff. The top of the diaphragm at the heart-diaphragm interface was identified as the point where the thoracic cavity contained the highest percentage of lung. MLAST then segmented the 3D shape of the diaphragm between the caudal end of the scan and the heart-diaphragm interface using the inflection point of each pixel’s intensity. All tissue identified as diaphragm was removed from the thoracic cavity and therefore from the volumes of the segmented tissues. This allowed MLAST to segment tumors located adjacent to the diaphragm and to decrease potentially confounding effects in the case of a large tumor at the heart-diaphragm interface. Fig 3 illustrates the various MLAST segmented slices of the lung from diaphragm to the tracheal bifurcation. The differential tissue densities are color-coded to represent different tissues (lung, soft tissue, intermediate, diaphragm and bone) as determined by MLAST. The MLAST results are expressed in terms of the percentage of the thoracic cavity made up of lung. Decreases in this lung percentage can be attributed to increases in tumor burden.

Fig 3. Representative slices of lung from a tumor-bearing mouse showing the resulting segmentation from the MLAST algorithm at various levels (3, 6, 9 and 12 mm) above the base of the diaphragm.

Fig 3

Top panel is MLAST only, middle panel is microCT only and the bottom panel is the overlay of MLAST and microCT images. The tissue labels for MLAST segmentation are color-coded for visual purposes: soft tissue (green), intermediate (cyan), lung (blue), diaphragm (red), and the mutlislice bone mask (yellow).

Histology

Tumor bearing animals were euthanized via CO2 inhalation. Lungs were perfused and incubated for 48h in formalin before embedding in paraffin. The FFPE blocks were sectioned 4 μm thick and stained with hematoxylin and eosin (H&E). Slides were scanned using a Leica/Aperio AT2 whole slide digital scanner at 20X magnification. Images were analyzed using Visiopharm 2017.7. First the lung tissue was detected, and the total lung area was calculated. Tumor lesions were then detected using a machine learning algorithm based on the random forest classifier. Results from Visiopharm were exported to Excel.

Statistical analysis

The MLAST scores, expressed as a percentage, were compared against the manual scores using Spearman’s rank correlation, and the outputs for each tumor category (1–3) were compared against the tumor free scans (category 0) with a series of Student’s t-tests using a Bonferroni-corrected alpha level of 0.0056.

Volumes segmented by MLAST were compared to those segmented manually (in both contrast and non-contrast scans) via linear regression with Pearson’s correlation. MLAST segmentations of the lung field were compared more directly to manually segmented non-contrast scans with a Dice similarity coefficient. Spearman’s rank correlation coefficient was used to compare MLAST measurement of % tumor burden with the % of tumor metastasis quantified from H&E images of lung sections.

Logistic regression was used to assess the drug’s treatment effect on the change in manual score from baseline to post treatment. In general, a proportional odd model could be used when more than two unique values of score change were observed. However, in this case only two unique values of score change was observed (the score was either unchanged or increased by 1), so a logistic regression was used. To evaluate the treatment effect on % lung calculated from MLAST, analysis of covariance (ANCOVA) was applied with baseline % lung as a covariate.

Results

Comparison of MLAST to qualitative manual scoring

Previously we used manual segmentation and contrast-enhanced microCT imaging to evaluate mouse models of lung tumor and response to therapy [13, 22]. Although these methods are quantitative, they are low-throughput and contrast is costly. Thus, we investigated alternative approaches to increase throughput and minimize variability within and between analysts. Manual scoring by an image analysis scientist was adopted to evaluate each animal’s lung tumor burden. We chose 446 scans from multiple studies on which to perform manual scoring. Samples with no lung tumors were assigned a score of 0, whereas lungs with very high tumor burden were scored as 3 (Fig 1, described in methods).

The MLAST algorithm was applied to 20 scans with a score of 0 to evaluate non-tumor bearing lung fields. In these scans, the thoracic cavity constituted ~43% lung, ~37% soft tissue, and ~19% intermediate tissue (Table 1). A representative pseudo-colored image panel and 3D flythrough of the thorax from the caudal to the cranial end is shown in Fig 3 and S1 Video. Later, MLAST was applied to all 446 scans which were manually scored. The MLAST outputs were then compared against the manual scores using a Spearman’s rank correlation, and the outputs for each tumor category (score 1–3) were compared against the tumor free scans (score 0) with a series of Student’s t-tests with a Bonferroni-corrected alpha level of 0.0056. Scans with higher manual scores showed a decrease in lung space and a simultaneous increase in the proportion of soft tissue and intermediate tissue (see Fig 4A and Table 1). The differences between the manual scores 1 and 2 were statistically significant for all 3 tissue types: lung, soft tissue, and intermediate tissue, whereas the differences between the manual scores 2 and 3 were significant for the soft tissue and lung. Notably, there were no statistically significant changes in the results between the 0 and 1 categories. Overall, the MLAST outputs had a Spearman’s rank correlation when compared with the manual scores of -0.69, 0.51, and 0.32 for lung, soft tissue, and intermediate tissue, respectively.

Table 1. Validation of MLAST with manual scoring (related to Fig 4A).

Score Soft Tissue Lung Intermediate
0 (n = 20) 37.34 +/- 0.47 43.36 +/-1.15 19.28 +/- 1.21
1 (n = 127) 37.62 +/- 0.36 41.85 +/- 0.48 20.52 +/- 0.45
2 (n = 202) 40.09 +/- 0.34 34.44 +/- 0.49 25.45 +/- 0.39
3 (n = 97) 48.56 +/- 0.81 25.80 +/- 0.69 25.62 +/- 0.56

Table showing mean +/- standard error of MLAST results expressed as % of thoracic cavity for scores 0, 1, 2, and 3.

Fig 4. Comparison of MLAST with manual scoring system and manual segmentation.

Fig 4

(A) Results comparing MLAST values (% thoracic cavity) to manual scores on a 0–3 scale. MLAST values represent soft tissue (green bar), lung (blue bar) and intermediate density (cyan bar). The number of samples that corresponded to manual scores 0–3 is represented in Y-axis. Error bars are standard error of mean and * indicates statistical significance by Student’s t-test at a Bonferroni-corrected significance level of α = 0.0056. (B) Comparison of the three methods: manual scored samples, manually segmented volume and MLAST values. Linear regression analysis of automatically segmented thoracic tissue (intermediate + soft tissue) by MLAST vs manually segmented thoracic soft tissue (heart + tumor) volume on a log scale show good corellation.

Comparison of MLAST to manual segmentation

We have shown that contrast-enhanced manual segmentation can produce quantitative tumor measurements [13] but is not a high-throughput method. We performed a side-by-side comparison of manual segmentation (Heart + Tumor volume) and corresponding MLAST-based segmentation (Soft + Intermediate tissue volume) from 10 non-contrast microCT scans in each qualitative manual scoring category, selected to ensure a wide distribution of tumor volumes. MLAST results were comparable to manual segmentation with a few notable distinctions (Fig 4B). Neither quantification approach indicated a statistically significant difference between the 0 and 1 manual scoring categories (which is not surprising with an ordinal scoring where 1 represents small, typically <5 mg, tumors and within MLAST signal to noise ratio (SNR)), though both demonstrated differences between higher categories. The overall relationship between the manually segmented volumes (slope = 0.7786, R2 = 0.8939, p < 0.0001) demonstrated a good correlation between the two methods, but with a considerable y-offset and a slope of <1. Analysis of the Sorenson-Dice similarity coefficient demonstrated a mean overlap of 85.43 +/- 6.0% (n = 29) between MLAST and manual segmentations of the lung field.

Comparison of MLAST to contrast-enhanced manual segmentation

Images from non-contrast microCT scans do not differentiate tissues with subtly different densities or vascularization. Vascular contrast agents such as Exitron nano-12000 can provide additional tissue contrast to differentiate between tumor and soft tissue [13]. To further demonstrate MLAST’s quantitation capability we compared MLAST-based segmentation (Soft + Intermediate tissue volume) and manual segmentation (Heart + Tumor volume) values from non-contrast microCT scans with manual segmentation of contrast-enhanced microCT images from the KL-GEM model of lung cancer (Fig 5A). MLAST showed a strong regression trend (R = 0.9252, p < 0.0001) compared with contrast-enhanced segmentation, with a similar slope (<1) and offset (>0) when compared to manual segmentation of non-contrast scans (Fig 5A). Interestingly, manual segmentation of non-contrast scans showed an even stronger relationship to contrast-enhanced segmentation (R = 0.9874, p < 0.0001) (Fig 5A). MLAST segmented volume at low tumor burden was higher than the manual segmentation. This is mainly due to the fact that MLAST segmentation includes the normal anatomy (heart, esophagus, and vasculature), which was excluded in the manual segmentation. Fig 5B shows the segmentation of lung field with low- and high-tumor burden from non-contrast microCT scans. Analysis of the non-contrast scans using a Sorenson-Dice similarity coefficient demonstrated a mean overlap of 85.40 +/- 3.0% (n = 8) between MLAST and manual segmentations of the lung field.

Fig 5. Comparison of MLAST using contrast-enhanced microCT imaging and histology.

Fig 5

(A) Validation results showing linear regression of MLAST and manually segmented volumes vs contrast-enhanced manual segmentation on a log scale. The volumes of MLAST-segmented non-contrast scans, which are made up of soft tissue and intermediate, are shown in orange. The volumes of manually segmented non-contrast scans, which are made up of heart and tumor, are shown in black. The x-axis represents the volumes of manually segmented contrast-enhanced scans, which are also made up of heart and tumor. Regression lines (solid) are shown for both results, along with a 95% Confidence Interval (dotted). (B) Representative scans with low and high tumor burden by manual and MLAST segmentation. (C) MLAST validation with histology: Representative H&E stained images with low and high tumor burden at low and high magnification. The graph shows the correlation of tumor burden evaluation by MLAST to H&E methods.

As a final validation step, MLAST measurements were compared with whole slide analysis of H&E images of 2D lung sections (Fig 5C). Histology is a validated alternative method to evaluate lung tumor burden either as correlative endpoint or if microCT imaging is not available in research facilities [13, 22]. We observed robust correlation between the % of tumor area measured from H&E images and MLAST measurement of the % of combined tissue, which includes the soft tissue and intermediate (Spearman’s correlation coefficient = 0.76).

Evaluating therapeutic efficacy in KL-GEM model

To showcase the utility of the MLAST tool in pre-clinical studies, we evaluated the efficacy of a known therapeutic drug in KL-GEM model of lung cancer. microCT imaging was performed before initiation of treatment (baseline) and after 3 weeks of treatment with the drug. The microCT scans were evaluated by manual scoring and MLAST analysis (Fig 6). Although manual scoring showed an improvement in the treatment group over the control group, this difference was not statistically significant (Fig 6A). In comparison to manual scoring, MLAST lung measurements demonstrated a larger difference between baseline and post-treatment scans (Fig 6B). The lung percentage in the vehicle-treated control group decreased by ~30%, whereas in the drug-treated group it increased by ~15%. Non-contrast microCT images showed an increased tumor burden in the vehicle-treated control compared to the drug-treated group (Fig 6C).

Fig 6. Utility of MLAST in an efficacy trial using Kras/Lkb1 GEM model.

Fig 6

(A) Manual scores assigned to scans from vehicle control (blue) and drug treatment (pink) groups before (baseline) and 3 weeks post-treatment regimen. (B) MLAST scores from vehicle (blue) and drug treatment (pink) groups before and post-treatment regimen. (C) Representative images from vehicle control and drug treated groups before and post-treatment. Images show profound progression of tumor in vehicle control group, but not in drug treated group. (n = 10/group; +/- SEM; ** = p-value < 0.0001).

Discussion

Our analyses show that the MLAST algorithm is capable of accurately detecting major changes in the tumor burden of lung microCT images from GEMM mice. The comparison of MLAST segmentations to manual scoring demonstrated that a decrease in segmented lung percentage correlates with an increase in tumor burden and that major differences in tumor burden produce statistically significant differences in segmented lung percentage. Although MLAST may not be ideally suited for detecting small, individual tumor nodules in the early stages of tumor development due to the lack of significant difference in lower scoring categories, it offers significant advantages over manual scoring when evaluating lungs with a heavy tumor burden and significant therapeutic effects. Readouts from MLAST are quantitative and objective, while manual scoring is time-consuming and is susceptible to both intra- and inter-analyst variability. In addition, MLAST offers improved quantification with higher precision to scan evaluation than captured by manual scoring (for example, between 2 and 3), allowing for improved sensitivity of tumor burden quantification. This effect is potentially useful at lesion margins where the analyst is unable to distinguish between proliferating tumor edges and other lesions such as tumor-compression induced atelectasis [23], peritumor edema associated with pseudoprogression [24], or at tumor-organ interfaces (as shown in Fig 5B).

MLAST is not the first automation tool for lung tissue segmentation. There have been other efforts made over the last few years to automate image analysis for oncology models, including non-small cell lung cancer. Much of the work has been done in clinical areas, including both semi-automated [25] and fully-automated [26, 27] approaches. More recently, researchers have worked to bring deep learning and neural networks to the world of CT lung analysis, some focusing on classification [28] and others on segmentation [29, 30]. While these developments are important for the field of clinical imaging, segmentation in pre-clinical imaging comes with its own unique set of challenges. Small-animal lung CT has considerable inherent motion and breathing artifact. Either prospective or retrospective respiratory gating can mitigate this problem, but both are time-consuming and often limit study throughput. Despite these challenges, several groups have developed semi-automated or even rules-based fully-automated algorithms for segmenting small animal lung microCT scans [25, 28, 29, 31, 32]. Haines et al. used a semi-automated threshold and region-grow algorithm to segment the combined tumor and vasculature (T&V) from the lung space with a correlation of R2 = 0.79 to histology results [15]. More recently Barck et al. developed an algorithm to perform fully-automated T&V segmentation in GEMM mice with a correlation to manual metrics in the range of r = 0.83–0.93 [14].

MLAST is an adaptation of the Barck approach with several improvements: it uses automated thresholding by k-means rather than pre-defined values and it employs an intra-scan normalization, both of which are designed to allow more flexibility. This design can accommodate variations in reconstruction parameters and sensitivity related to position in the gantry, as well as drifts in signal calibration. MLAST also requires minimal preprocessing and can be used across different scanners. Its flexibility allows the tool to be used on a diverse range of GEM models, orthotopic tumors, and non-oncology applications with gradations of density such as fibrosis [33] and pneumonia [34]. We have also refined the Barck mask function by stacking multiple slices before applying the spline function, which smooths the transition between slices and eliminates the inclusion of intercostal muscles. Finally, the diaphragm detection algorithm used by MLAST allows for inclusion of tumors at the lower lung region near the diaphragm that may otherwise be difficult to segment.

Comparison with manual segmentation volumes demonstrated the precision of tissue segmentation by MLAST. Tissue volumes calculated by automated segmentation compared well with those derived from manual segmentation, underscoring reliability of the algorithm for computation of tissue volumes in the thoracic cavity. Interestingly, neither MLAST nor manual segmentation was able to differentiate between scans scored 0–1, likely due to the relatively low impact of small tumors on the overall tissue volume in the thoracic cavity. The non-zero y-offset in the MLAST-segmented volumes is largely due to the volume of normal anatomy (heart, esophagus, and vasculature) which was included in the MLAST segmentation but not in the manual segmentation. Additionally, the vasculature is more visible in low-burden than high-burden scans where it merges with tumors, contributing to a regression slope of less than one, as the difference in volume between the MLAST segmentations and manual segmentations lessened in the higher-burden scans where the vasculature was merged with the tumor lesions (which is only distinguishable with contrast enhancement [35]).

Contrast-enhanced manual segmentation is considered a “gold standard” for quantitative CT imaging [13]. Thus, we compared MLAST measurements with manual segmentation of contrast-enhanced microCT images from the KL-GEM model. The high correlation between the manually-segmented tissue volumes with and without contrast indicates that our manual segmentations in both experiments were consistent and accurate relative to ground truth. The experiment confirmed that MLAST tissue segmentations were well correlated with manual segmentations and demonstrated its precision against the gold standard of contrast-enhanced manual lung segmentation.

The implementation of MLAST on a study to evaluate the anti-tumor effects of a therapeutic on KL-GEM tumors demonstrated the power of MLAST to detect treatment response. The quantitative measurements determined with MLAST allowed for detection of subtle differences within scoring categories, as the ordinal label of 3 does not seem to have fully captured the extent to which the tumors grew in the control group. Thus, MLAST was able to detect volumetric changes in tumors in the treatment group that could not be found by the manual scoring system. There is no significant change in either lung volume or overall thoracic volume with age in non-tumor bearing mice within our typical experimental time window [36]. Therefore we assume no age-related effects. This study provides an example of how MLAST has much potential value to the process of drug development as a tool to enhance sensitivity and increase quantitative power over ordinal binning in studies with moderate to heavy tumor burden.

Apart from quantitation and sensitivity, MLAST also offers efficiency. It can analyze a scan in approximately 1/5th of the time required for manual scoring (data not shown), and this speed can be further improved by running the algorithm on multiple CPUs at once. Entire studies could potentially be analyzed in only a few minutes without being monitored by a scientist, allowing for greater efficiency, faster data turnaround time, and more frequent intermediate readouts in longitudinal studies. MLAST could therefore enable drug development scientists to make decisions in near-real time and collect more frequent datapoints.

These benefits of a fully-automated, quantitative approach could be expanded even further in the future with the adaptation of a deep learning model for segmentation of pre-clinical lung CTs. If a training library of enough pre-segmented images could be generated, a U-Net model could be trained to segment tumor region specifically, rather than relying on quantification of the loss of lung tissue. It is reasonable to assume that a direct segmentation of the tumor itself would have an improved accuracy in tracking disease progression and would allow for further possibilities of analysis of those tumor nodules. Such an approach would be largely beneficial and should be pursued in the future.

The flexibility, ease-of-use, and efficiency of MLAST make it a valuable analytical asset for pre-clinical efficacy studies involving lung cancer as well as potentially for other models of pulmonary pathology. Automated analysis can potentially be applied to many other imaging paradigms to perform similarly quantitative, efficient analyses in a variety of bio-pharmaceutical therapeutic areas.

Supporting information

S1 Video. Full 3D flythrough of a representative lung from a tumor-bearing mouse show the segmentation from MLAST algorithm.

(AVI)

S1 Table. Raw minimal data for Fig 4A.

Manual scoring and MLAST results are shown for all subjects used in comparing manual scoring to MLAST segmentation. Manual scores are shown on a 0–3 scale and MLAST results are shown as % of total thoracic tissue.

(XLSX)

S2 Table. Raw minimal data for Fig 4B.

Manual scores, manual segmentation volumes, and MLAST segmentation volumes are shown for scans used in comparing manual segmentation to MLAST segmentation. Volumes were calculated from pixel counts using an isometric pixel size of 100 μm, and are shown in mm3.

(XLSX)

S3 Table. Raw minimal data for Fig 5A.

Non-lung tissue volumes are shown as computed using manual segmentation in contrast-enhanced scans, manual segmentation in non-contrast scans, and MLAST segmentation in non-contrast scans for subjects at various time points post tumor induction. All volumes are in mm3.

(XLSX)

S4 Table. Raw minimal data for Fig 5C.

Tumor burdens as calculated by histology and MLAST are shown for the subjects used in comparing MLAST to contrast-enhanced manual segmentation.

(XLSX)

S5 Table. Raw minimal data for Fig 6.

Manual scoring and MLAST results are shown for vehicle and treatment subjects at week 0 (pre-treatment) and week 3 (post-treatment). Manual scores are shown on a 0–3 scale and MLAST results are shown as % of total thoracic tissue.

(XLSX)

Acknowledgments

Comparative Medicine, Pfizer Inc., for care of the animals, technical support, and funding. We thank Julita Ramirez (Comparative Medicine–Global Science and Technology, Pfizer Inc.) for editing the manuscript.

MLAST Tool can be accessed at: https://www.protocols.io/private/12BD8BC1A93211EB938A0A58A9FEAC02

Data Availability

All relevant data are within the paper and Supporting Information files.

Funding Statement

This project was funded by Pfizer, Inc. Pfizer Inc. provided financial support in the form of research materials and salaries for authors [MKM, JD, HZ, SR, SD, VP, LM, KJ, AG], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.

References

  • 1.Pirker R. Conquering lung cancer: current status and prospects for the future. Pulmonology. 2020;26(5):283–90. Epub 2020/03/23. doi: 10.1016/j.pulmoe.2020.02.005 . [DOI] [PubMed] [Google Scholar]
  • 2.Ai X, Guo X, Wang J, Stancu AL, Joslin PMN, Zhang D, et al. Targeted therapies for advanced non-small cell lung cancer. Oncotarget. 2018;9(101):37589–607. Epub 2019/01/27. doi: 10.18632/oncotarget.26428 ; PubMed Central PMCID: PMC6331020. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Dawe DE, Harlos CH, Juergens RA. Immuno-oncology-the new paradigm of lung cancer treatment. Curr Oncol. 2020;27(Suppl 2):S78–S86. Epub 2020/05/06. doi: 10.3747/co.27.5183 ; PubMed Central PMCID: PMC7194003. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Hu Z, Li M, Chen Z, Zhan C, Lin Z, Wang Q. Advances in clinical trials of targeted therapy and immunotherapy of lung cancer in 2018. Transl Lung Cancer Res. 2019;8(6):1091–106. Epub 2020/02/06. doi: 10.21037/tlcr.2019.10.17 ; PubMed Central PMCID: PMC6976346. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Kunimasa K, Goto T. Immunosurveillance and Immunoediting of Lung Cancer: Current Perspectives and Challenges. Int J Mol Sci. 2020;21(2). Epub 2020/01/23. doi: 10.3390/ijms21020597 ; PubMed Central PMCID: PMC7014343. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Oser MG, Niederst MJ, Sequist LV, Engelman JA. Transformation from non-small-cell lung cancer to small-cell lung cancer: molecular drivers and cells of origin. Lancet Oncol. 2015;16(4):e165–72. Epub 2015/04/08. doi: 10.1016/S1470-2045(14)71180-5 ; PubMed Central PMCID: PMC4470698. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Solomon BJ, Mok T, Kim DW, Wu YL, Nakagawa K, Mekhail T, et al. First-line crizotinib versus chemotherapy in ALK-positive lung cancer. N Engl J Med. 2014;371(23):2167–77. Epub 2014/12/04. doi: 10.1056/NEJMoa1408440 . [DOI] [PubMed] [Google Scholar]
  • 8.Chen Z, Cheng K, Walton Z, Wang Y, Ebi H, Shimamura T, et al. A murine lung cancer co-clinical trial identifies genetic modifiers of therapeutic response. Nature. 2012;483(7391):613–7. doi: 10.1038/nature10937 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Kellar A, Egan C, Morris D. Preclinical Murine Models for Lung Cancer: Clinical Trial Applications. Biomed Res Int. 2015;2015:621324. Epub 2015/06/13. doi: 10.1155/2015/621324 ; PubMed Central PMCID: PMC4433653. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Schwartz LH, Litiere S, de Vries E, Ford R, Gwyther S, Mandrekar S, et al. RECIST 1.1-Update and clarification: From the RECIST committee. Eur J Cancer. 2016;62:132–7. Epub 2016/05/18. doi: 10.1016/j.ejca.2016.03.081 ; PubMed Central PMCID: PMC5737828. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Fushiki H, Kanoh-Azuma T, Katoh M, Kawabata K, Jiang J, Tsuchiya N, et al. Quantification of mouse pulmonary cancer models by microcomputed tomography imaging. Cancer Sci. 2009;100(8):1544–9. Epub 2009/05/23. doi: 10.1111/j.1349-7006.2009.01199.x . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Gallastegui A, Cheung J, Southard T, Hume KR. Volumetric and linear measurements of lung tumor burden from non-gated micro-CT imaging correlate with histological analysis in a genetically engineered mouse model of non-small cell lung cancer. Lab Anim. 2018;52(5):457–69. Epub 2018/02/14. doi: 10.1177/0023677218756457 . [DOI] [PubMed] [Google Scholar]
  • 13.Lalwani K, Giddabasappa A, Li D, Olson P, Simmons B, Shojaei F, et al. Contrast agents for quantitative microCT of lung tumors in mice. Comp Med. 2013;63(6):482–90. Epub 2013/12/12. ; PubMed Central PMCID: PMC3866987. [PMC free article] [PubMed] [Google Scholar]
  • 14.Barck KH, Bou-Reslan H, Rastogi U, Sakhuja T, Long JE, Molina R, et al. Quantification of Tumor Burden in a Genetically Engineered Mouse Model of Lung Cancer by Micro-CT and Automated Analysis. Transl Oncol. 2015;8(2):126–35. Epub 2015/05/01. doi: 10.1016/j.tranon.2015.03.003 ; PubMed Central PMCID: PMC4415142. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Haines BB, Bettano KA, Chenard M, Sevilla RS, Ware C, Angagaw MH, et al. A quantitative volumetric micro-computed tomography method to analyze lung tumors in genetically engineered mouse models. Neoplasia. 2009;11(1):39–47. Epub 2008/12/25. doi: 10.1593/neo.81030 ; PubMed Central PMCID: PMC2606117. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Gibson-Corley KN, Olivier AK, Meyerholz DK. Principles for valid histopathologic scoring in research. Vet Pathol. 2013;50(6):1007–15. Epub 2013/04/06. doi: 10.1177/0300985813485099 ; PubMed Central PMCID: PMC3795863. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.DuPage M, Dooley AL, Jacks T. Conditional mouse lung cancer models using adenoviral or lentiviral delivery of Cre recombinase. Nat Protoc. 2009;4(7):1064–72. Epub 2009/06/30. doi: 10.1038/nprot.2009.95 ; PubMed Central PMCID: PMC2757265. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Ullman-Cullere MH, Foltz CJ. Body condition scoring: a rapid and accurate method for assessing health status in mice. Lab Anim Sci. 1999;49(3):319–23. Epub 1999/07/14. . [PubMed] [Google Scholar]
  • 19.Du S, Lockamy V, Zhou L, Xue C, LeBlanc J, Glenn S, et al. Stereotactic Body Radiation Therapy Delivery in a Genetically Engineered Mouse Model of Lung Cancer. Int J Radiat Oncol Biol Phys. 2016;96(3):529–37. Epub 2016/09/30. doi: 10.1016/j.ijrobp.2016.07.008 ; PubMed Central PMCID: PMC5380923. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Zou KH, Warfield SK, Bharatha A, Tempany CMC, Kaus MR, Haker SJ, et al. Statistical validation of image segmentation quality based on a spatial overlap index1: scientific reports. Academic Radiology. 2004;11(2):178–89. 10.1016/S1076-6332(03)00671-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Hutchinson BD, Shroff GS, Truong MT, Ko JP. Spectrum of Lung Adenocarcinoma. Semin Ultrasound CT MR. 2019;40(3):255–64. Epub 2019/06/16. doi: 10.1053/j.sult.2018.11.009 . [DOI] [PubMed] [Google Scholar]
  • 22.Simmons BH, Lee JH, Lalwani K, Giddabasappa A, Snider BA, Wong A, et al. Combination of a MEK inhibitor at sub-MTD with a PI3K/mTOR inhibitor significantly suppresses growth of lung adenocarcinoma tumors in Kras(G12D-LSL) mice. Cancer Chemother Pharmacol. 2012;70(2):213–20. Epub 2012/06/12. doi: 10.1007/s00280-012-1899-6 . [DOI] [PubMed] [Google Scholar]
  • 23.Yang RM, Li L, Wei XH, Guo YM, Huang YH, Lai LS, et al. Differentiation of central lung cancer from atelectasis: comparison of diffusion-weighted MRI with PET/CT. PLoS One. 2013;8(4):e60279. Epub 2013/04/18. doi: 10.1371/journal.pone.0060279 ; PubMed Central PMCID: PMC3617228. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Ma Y, Wang Q, Dong Q, Zhan L, Zhang J. How to differentiate pseudoprogression from true progression in cancer patients treated with immunotherapy. Am J Cancer Res. 2019;9(8):1546–53. Epub 2019/09/10. ; PubMed Central PMCID: PMC6726978. [PMC free article] [PubMed] [Google Scholar]
  • 25.Gu Y, Kumar V, Hall LO, Goldgof DB, Li CY, Korn R, et al. Automated Delineation of Lung Tumors from CT Images Using a Single Click Ensemble Segmentation Approach. Pattern Recognit. 2013;46(3):692–702. Epub 2013/03/06. doi: 10.1016/j.patcog.2012.10.005 ; PubMed Central PMCID: PMC3580869. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Sun S, Bauer C, Beichel R. Automated 3-D segmentation of lungs with lung cancer in CT data using a novel robust active shape model approach. IEEE Trans Med Imaging. 2012;31(2):449–60. Epub 2011/10/15. doi: 10.1109/TMI.2011.2171357 ; PubMed Central PMCID: PMC3657761. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Zhou J, Yan Z, Lasio G, Huang J, Zhang B, Sharma N, et al. Automated compromised right lung segmentation method using a robust atlas-based active volume model with sparse shape composition prior in CT. Comput Med Imaging Graph. 2015;46 Pt 1:47–55. Epub 2015/08/11. doi: 10.1016/j.compmedimag.2015.07.003 . [DOI] [PubMed] [Google Scholar]
  • 28.Anthimopoulos M, Christodoulidis S, Ebner L, Christe A, Mougiakakou S. Lung Pattern Classification for Interstitial Lung Diseases Using a Deep Convolutional Neural Network. IEEE Trans Med Imaging. 2016;35(5):1207–16. Epub 2016/03/10. doi: 10.1109/TMI.2016.2535865 . [DOI] [PubMed] [Google Scholar]
  • 29.Jiang J HY, Liu CJ, Halpenny D, Hellmann MD, Deasy JO, Mageras G, et al. Multiple Resolution Residually Connected Feature Streams for Automatic Lung Tumor Segmentation from CT Images. IEEE Transactions on Medical Imaging. 2018;38(1):134–44. Epub July 23 2018. doi: 10.1109/TMI.2018.2857800 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Park J, Yun J, Kim N, Park B, Cho Y, Park HJ, et al. Fully Automated Lung Lobe Segmentation in Volumetric Chest CT with 3D U-Net: Validation with Intra- and Extra-Datasets. J Digit Imaging. 2019;33(1):221–30. Epub 2019/06/04. doi: 10.1007/s10278-019-00223-1 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Yu Guo YF, Sun Jian, Zhang Ning, Lin Wang, Sa Yu, Wang Ping. Automatic Lung Tumor Segmentation on PET/CT Images Using Fuzzy Markov Random Field Model. Computational and Mathematical Methods in Medicine. 2014;401201. Epub Mary 29 2014. doi: 10.1155/2014/401201 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Leung K, Marashdeh W, Wray R, Ashrafinia S, Rahmim A, Pomper M, et al. A deep-learning-based fully automated segmentation approach to delineate tumors in FDG-PET images of patients with lung cancer. Journal of Nuclear Medicine. 2018;59(supplement 1):323. [Google Scholar]
  • 33.Gilhodes JC, Jule Y, Kreuz S, Stierstorfer B, Stiller D, Wollin L. Quantification of Pulmonary Fibrosis in a Bleomycin Mouse Model Using Automated Histological Image Analysis. PLoS One. 2017;12(1):e0170561. Epub 2017/01/21. doi: 10.1371/journal.pone.0170561 ; PubMed Central PMCID: PMC5249201 statement does not alter the adherence to all PLOS ONE policies on sharing data and materials. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Armbrust LJ, Mosier DA, Nelson EL, Hart ML, Chapes SK. Correlation of results of pulmonary computed tomography and pathologic findings in mice with Pasteurella-induced pneumonia. Am J Vet Res. 2005;66(5):835–8. Epub 2005/06/09. doi: 10.2460/ajvr.2005.66.835 . [DOI] [PubMed] [Google Scholar]
  • 35.Subhawong TK, Fishman EK, Swart JE, Carrino JA, Attar S, Fayad LM. Soft-tissue masses and masslike conditions: what does CT add to diagnosis and management? AJR Am J Roentgenol. 2010;194(6):1559–67. Epub 2010/05/22. doi: 10.2214/AJR.09.3736 ; PubMed Central PMCID: PMC2884142. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Schulte H, Muhlfeld C, Brandenberger C. Age-Related Structural and Functional Changes in the Mouse Lung. Front Physiol. 2019;10:1466. Epub 2019/12/24. doi: 10.3389/fphys.2019.01466 ; PubMed Central PMCID: PMC6904284. [DOI] [PMC free article] [PubMed] [Google Scholar]

Decision Letter 0

Joseph Najbauer

16 Feb 2021

Pécs, Hungary

February 15, 2021

PONE-D-20-38790

Mouse Lung Automated Segmentation Tool for Quantifying Lung Tumors after Micro-Computed Tomography

PLOS ONE

Dear Dr. Giddabasappa,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised by the Reviwers, listed below.

Please submit your revised manuscript by Apr 02 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

Please include the following items when submitting your revised manuscript:

  • A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols

We look forward to receiving your revised manuscript.

Kind regards,

Joseph Najbauer, Ph.D.

Academic Editor

PLOS ONE

------------------------------------------------------------------------

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. We note in your Data Availability statement you have advised "No - some restrictions will apply". Could you please  clarify the nature of these restrictions, ie. if due to ethical or legal reasons.

PLOS defines a study's minimal data set as the underlying data used to reach the conclusions drawn in the manuscript and any additional data required to replicate the reported study findings in their entirety. All PLOS journals require that the minimal data set be made fully available. For more information about our data policy, please see http://journals.plos.org/plosone/s/data-availability.

Upon re-submitting your revised manuscript, please upload your study’s minimal underlying data set as either Supporting Information files or to a stable, public repository and include the relevant URLs, DOIs, or accession numbers within your revised cover letter. For a list of acceptable repositories, please see http://journals.plos.org/plosone/s/data-availability#loc-recommended-repositories. Any potentially identifying patient information must be fully anonymized.

Important: If there are ethical or legal restrictions to sharing your data publicly, please explain these restrictions in detail. Please see our guidelines for more information on what we consider unacceptable restrictions to publicly sharing data: http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions. Note that it is not acceptable for the authors to be the sole named individuals responsible for ensuring data access.

We will update your Data Availability statement to reflect the information you provide in your cover letter.

3. Thank you for providing the following Funding Statement: 

"This project was funded by Pfizer, Inc."

We note that one or more of the authors is affiliated with the funding organization, indicating the funder may have had some role in the design, data collection, analysis or preparation of your manuscript for publication; in other words, the funder played an indirect role through the participation of the co-authors.

If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study in the Author Contributions section of the online submission form. Please make any necessary amendments directly within this section of the online submission form.  Please also update your Funding Statement to include the following statement: “The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”

If the funding organization did have an additional role, please state and explain that role within your Funding Statement.

Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.  

Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests). If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.

Please know it is PLOS ONE policy for corresponding authors to declare, on behalf of all authors, all potential competing interests for the purposes of transparency. PLOS defines a competing interest as anything that interferes with, or could reasonably be perceived as interfering with, the full and objective presentation, peer review, editorial decision-making, or publication of research or non-research articles submitted to one of the journals. Competing interests can be financial or non-financial, professional, or personal. Competing interests can arise in relationship to an organization or another person. Please follow this link to our website for more details on competing interests: http://journals.plos.org/plosone/s/competing-interests

4. We note that you have included the phrase “data not shown” in your manuscript. Unfortunately, this does not meet our data sharing requirements. PLOS does not permit references to inaccessible data. We require that authors provide all relevant data within the paper, Supporting Information files, or in an acceptable, public repository. Please add a citation to support this phrase or upload the data that corresponds with these findings to a stable repository (such as Figshare or Dryad) and provide and URLs, DOIs, or accession numbers that may be used to access these data. Or, if the data are not a core part of the research being presented in your study, we ask that you remove the phrase that refers to these data.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #1: Partly

Reviewer #2: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #1: N/A

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #1: No

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #1: In this paper, the authors describe a new method that enables quick automatic segmentation of lung tumor in small animal models that might have use in drug studies. Experiments seem to have been conducted properly and results are interesting. However, the statements done regarding the results obtained are over rated and more self-critic is recommended.

My comments follow:

(1) Line 42: Please define what the intermediate region is. There is no definition of it in the text and it must be given in detail.

(2) Lines 107 and 109: Attention to the subscripts for carbon dioxide.

(3) Line 134: is it resolution or pixel size? The images suggest it is pixel size, not resolution.

(4) Line 105: it is Feldkamp, not Fledkamp.

(5) Lines 144-147: what is the size of a “small tumor nodule”? Precise values for “small”, “medium”, and “large” are needed here. An explanation is given in the legend of Fig 1 and more should be written in the main manuscript text.

(6) Line 128 and 279: KL-GEM or KL GEM?

(7) Line 148: write Amira 6.3 (ThermoFischer...).

(8) Line 160 - 162: please give a precise definition of a “significant decrease in the percentage of lung volume” must be given. As it is written, it is too imprecise.

(9) Line 205: Use “h”, not “hours”.

(10) Line 230: Title seems to be incomplete. It is a comparison of what to what?

(11) Figure 4 is hard to understand. Fig 4A: it is said it is a comparison of manual score with MLAST, but only the results of manual segmentation are shown (or only MLAST? The figure and the legend apparently do not match). Fig 4B: Why heart + tumor volume manually estimated should have a correlation with MLAST-based estimation of soft tissue + intermediate? Maybe this is obvious for the authors, but is not written in the text. Again, the same for Fig. 5. A and B. A comparison of manual segmentation to MLAST segmentation is the core of the paper, tough no explanation is given for why this comparison (heart + tumor volume vs. soft tissue + intermediate) makes sense scientifically and is the best that can be achieved in the context of this work. Then in Fig 5 C, the comparison of MLAST and histology only considers the tumor area for histology and soft tissue + intermediate for MLAST. Why is there a different comparison for histology?

(12) Line 250: I believe there’s something wrong with this sentence.

(13) Line 261: correct “side-by-side”.

(14) Line 279: a definition of KL-GEM model is needed in the methods part.

(15) Line 287: “Figure 5B shows the segmentation of lung. The results of manual and MLAST segmentation are obviously different and this different has to be addressed in the text. Of course, manual and MLAST segmentation are going to be different, but are the differences relevant? If not, why? The authors are interested in the statistical differences between the groups studied, but these differences in segmentation cannot be overlooked and the minimum number of scanned animals to give relevant results should be given.

(16) Line 296 and 303 (and other parts in the text): micro-CT or mCT? Choose one or other, because using both terms shows lack of consistency.

(17) Line 302: what is vehicle-treated group? Is it the control group? Clear information in the methods part is needed and the use of the term “control group” is recommended.

(18) Line 318: What is “finer granularity to scan evaluation”? A clear definition must be given.

(19) Line 320: a comparison of the images in Fig 3 (segmented-top and original-bottom) shows that MLAST overestimates the boarder of the bones. From the images, I cannot say for sure if the same happens with boarders within soft-tissue, but a rough visual analysis suggests unclear boarders between tissue types. Thus, I definitely do not agree with “This effect is potentially useful at lesion margins where the analyst is unable to distinguish between proliferating tumor edges and other lesions such as tumor compression induced atelectasis [22], peritumor edema associated with pseudoprogression [23], or at tumor-organ interfaces (as shown in Figure 5B).” More explanation and less speculation are needed here. Also, maybe the authors should consider presenting Fig 3 as Fig 5 B (superposition of the segmented areas in transparent colors on the micro-CT slice).

(20) Line 327: I recommend to add more references to the “semi-automated and fully-automated approaches”.

(21) Lines 357 and 370: the same statement is given twice, at the beginning and at the end of the paragraph: “Comparison with manual segmentation volumes demonstrated the accuracy of tissue segmentation by MLAST”. Once should be enough. However, as commented before, I see a problem in this comparison and, thus, this statement is questionable. A proper explanation and scientific basis for this comparison must be given.

(22) Line 373: “compared”, not “correlated”.

(23) Line 357-358: I do not agree with “Comparison with manual segmentation volumes demonstrated the accuracy of tissue segmentation by MLAST.” Fig 5 C shows some statistical correlation in the measurements, but does not really show accuracy. Is it possible to show figures such as Fig. 4 in https://doi.org/10.1038/s41598-018-37394-w? This would show accuracy. More self-critic is recommended.

(24) Line 382 - 384: Why is MLAST a “dynamic measurement”? Are the “subtle differences within scoring categories” relevant or they are an error of the method? How to tell the difference?

(25) Line 389-392: I agree that MLAST “has much potential value to the process of drug development”. It for sure can increase provide quick results that, within different populations, has a statistical relevance. However, I do not agree that the results indicate that it is more sensitive than the other methods used.

(26) Legends of Fig. 4 and 5: The use of the word “validation” is questionable. The figures show a comparison of the results, but do not show a proof, or a confirmation, as the word “validation” suggests. Use of “comparison” is more appropriate.

Reviewer #2: The authors describe a workflow to automatically analyze the lungs of mice that were imaged using µCT. This work describes a practical solution to a task in pharmaceutical research that should inspire the community to use processes that accelerate the search of new treatments against cancer.

Tumor growth will change the lung tissue composition and will become visible in the x-ray images. Based on the setup described here, tumor growth should give a strong signal and this would allow different ways for an analysis such as visual classification, or a densitometric analysis (i.e. shifts in voxel intensity histograms), or a size measurement after lung segmentation.

The authors use a size measurement after lung segmentation and describe the steps needed for a robust and fully automized procedure.

The results are compared to an analysis based on ground truth segmentation generated by human experts, a tumor burden score also performed by a human expert, and readouts generated from histology. The correlation proves the usability of the authors approach.

In Fig 2A a histogram of density values is shown. Histogram analysis seems to be a common tool in x-ray image analysis and would probably give information about the health state of lungs. The authors should discuss why they did not use the densitometry data to also analyze tumor presence or have they tried this with unsatisfactory results.

Fig 5A shows the weak part of the MLAST approach. Small tumor nodules in lung lobes that can easily be seen and used in a scoring scheme, can also be marked in a manual segmentation, but will have little effect on volumetric measurements. The smoothing effect of the clustering in MLAST leads to a significant offset. In the discussion the authors explain in detail all the effects caused by the different analysis methods used.

However neuronal networks are not used for this work. The authors argue that a deep learning approach to classify or segment the lung was not feasible because of missing ground truth in the public domain and therefore not considered. For the evaluation of their MLAST procedure they generated over 3500 ground truth images for segmentation and used 446 lungs for scoring, a source for ten thousands of images for a classification training. In the case of tumor burden in lungs this is sufficient material for an application using deep learning. The authors should rethink their arguments.

This manuscript describes in great detail a practical solution to a segmentation task. Alternative solutions that might even be easier and faster, are not discussed, but should be worth a few sentences.

**********

6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #1: No

Reviewer #2: No

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.

Decision Letter 1

Joseph Najbauer

26 May 2021

Pécs, Hungary

May 25, 2021

Mouse Lung Automated Segmentation Tool for Quantifying Lung Tumors after Micro-Computed Tomography

PONE-D-20-38790R1

Dear Dr. Giddabasappa,

We’re pleased to inform you that your manuscript (R1 version) has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

PLEASE SEE THE COMMENT BY REVIEWER #2 BELOW (point 6).

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Joseph Najbauer, Ph.D.

Academic Editor

PLOS ONE

---------------------------------------------------

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation.

Reviewer #2: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions?

The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented.

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?

Reviewer #2: N/A

**********

4. Have the authors made all data underlying the findings in their manuscript fully available?

The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified.

Reviewer #2: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English?

PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here.

Reviewer #2: Yes

**********

6. Review Comments to the Author

Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters)

Reviewer #2: I recommend using the term microCT or µCT, but not mCT. m is usually considered milli and so the short form would be milliCT.

**********

7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy.

Reviewer #2: No

Acceptance letter

Joseph Najbauer

8 Jun 2021

PONE-D-20-38790R1

Mouse Lung Automated Segmentation Tool for Quantifying Lung Tumors after Micro-Computed Tomography

Dear Dr. Giddabasappa:

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department.

If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org.

If we can help with anything else, please email us at plosone@plos.org.

Thank you for submitting your work to PLOS ONE and supporting open access.

Kind regards,

PLOS ONE Editorial Office Staff

on behalf of

Dr. Joseph Najbauer

Academic Editor

PLOS ONE

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Video. Full 3D flythrough of a representative lung from a tumor-bearing mouse show the segmentation from MLAST algorithm.

    (AVI)

    S1 Table. Raw minimal data for Fig 4A.

    Manual scoring and MLAST results are shown for all subjects used in comparing manual scoring to MLAST segmentation. Manual scores are shown on a 0–3 scale and MLAST results are shown as % of total thoracic tissue.

    (XLSX)

    S2 Table. Raw minimal data for Fig 4B.

    Manual scores, manual segmentation volumes, and MLAST segmentation volumes are shown for scans used in comparing manual segmentation to MLAST segmentation. Volumes were calculated from pixel counts using an isometric pixel size of 100 μm, and are shown in mm3.

    (XLSX)

    S3 Table. Raw minimal data for Fig 5A.

    Non-lung tissue volumes are shown as computed using manual segmentation in contrast-enhanced scans, manual segmentation in non-contrast scans, and MLAST segmentation in non-contrast scans for subjects at various time points post tumor induction. All volumes are in mm3.

    (XLSX)

    S4 Table. Raw minimal data for Fig 5C.

    Tumor burdens as calculated by histology and MLAST are shown for the subjects used in comparing MLAST to contrast-enhanced manual segmentation.

    (XLSX)

    S5 Table. Raw minimal data for Fig 6.

    Manual scoring and MLAST results are shown for vehicle and treatment subjects at week 0 (pre-treatment) and week 3 (post-treatment). Manual scores are shown on a 0–3 scale and MLAST results are shown as % of total thoracic tissue.

    (XLSX)

    Attachment

    Submitted filename: Response to Reviewers - PONE-D-20-38790-R1.docx

    Data Availability Statement

    All relevant data are within the paper and Supporting Information files.


    Articles from PLoS ONE are provided here courtesy of PLOS

    RESOURCES