Abstract
Purpose
This study aimed to determine whether unrestricted weight-bearing as tolerated (WBAT) following lateral locking plate (LLP) fixation of periprosthetic distal femoral fractures (PDFFs) is associated with increased failure and reoperation, compared with restricted weight-bearing (RWB).
Materials and methods
In a retrospective cohort study of consecutive patients with unilateral PDFFs undergoing LLP fixation, patients prescribed WBAT were compared with those prescribed 6 weeks of RWB. The primary outcome measure was reoperation. Kaplan–Meier and Cox multivariable analyses were performed.
Results
There were 43 patients (mean age 80.9 ± 11.7 years, body mass index 26.8 ± 5.7 kg/m2 and 86.0% female): 28 WBAT and 15 RWB. There were more interprosthetic fractures in the RWB group (p = 0.040). Mean follow-up was 3.8 years (range 1.0–10.4). Eight patients (18.6%) underwent reoperation. Kaplan–Meier analysis demonstrated no difference in 2-year survival between WBAT (80.6%, 95% CI 65.3–95.9) and RWB (83.3%, 95% CI 62.1–100.0; p = 0.54). Cox analysis showed increased reoperation risk with medial comminution (hazard ratio 10.7, 95% CI 1.5–80; p = 0.020) and decreased risk with anatomic reduction (hazard ratio 0.11, 95% CI 0.01–1.0; p = 0.046). Immediate weight-bearing did not significantly affect the risk of reoperation compared with RWB (relative risk 1.03, 95% CI 0.61–1.74; p = 0.91).
Conclusions
LLP fixation failure was associated with medial comminution and non-anatomic reductions, not with postoperative weight-bearing. Medial comminution should be managed with additional fixation. Weight-bearing restrictions additional to this appear unnecessary and should be avoided.
Keywords: Periprosthetic fracture, Distal femur fracture, Lateral locking plate fixation, Weight-bearing
Introduction
The number of primary total knee arthroplasties (TKAs) performed is increasing annually [1]. In the context of an aging population [2], periprosthetic distal femoral fractures (PDFFs) represent an increasing burden on patients and surgeons [3–5], with a current incidence estimated at 2.4 per 100,000 population per year [6]. These fractures are typically fragility fractures affecting older and often frail patients [7]. Where fractures are proximal to well-fixed femoral components with adequate bone stock, they are usually managed with fixation, as opposed to revision arthroplasty [4]. Although proximal diaphyseal-type fractures can be treated with retrograde femoral nailing [8], where fixation is undertaken for more distal fractures a lateral locking plate (LLP) is typically used, with or without additional augmentation [9, 10].
Guidelines for the management of femoral fragility fractures emphasize the importance of early mobilization [11, 12]. Unrestricted early weight-bearing improves functional mobility and the likelihood of discharge home, and reduces both complications and mortality in these vulnerable patients [13–15]. These guidelines are generally followed for fractures of the proximal femur [16]; however, similar arguments are not always made for fractures of the distal femur, for which weight-bearing restrictions are often prescribed due to concerns regarding fixation failure [9, 17–20]. This has led some authors to recommend distal femoral replacement in preference to fixation, in order to facilitate immediate and unrestricted weight-bearing [21, 22]. It has previously been shown in two cohorts of patients with distal femoral fractures, including both native and periprosthetic fractures, that modern locking plates facilitate safe early weight-bearing with low rates of failure in the management of distal femoral fractures [5, 23]. In studies limited to patients with PDFFs, postoperative weight-bearing status has either been restricted [9, 20] or not reported [10]. The safety of unrestricted weight-bearing after LLP fixation of PDFFs has been reported by Smith et al. [24], although no comparative group was included.
The aim of this retrospective study was to determine whether immediate unrestricted weight-bearing following LLP fixation of PDFFs was associated with increased fixation failure and reoperation, compared with 6 weeks of restricted weight-bearing (RWB). The null hypothesis was that there would be no difference in failure and reoperation rates between the unrestricted and RWB groups. Secondary outcomes included perioperative complications, functional mobility status, length of acute hospital stay, discharge destination and mortality.
Materials and methods
This retrospective cohort study was approved by the institutional musculoskeletal audit and quality improvement group. Consecutive patients with PDFFs involving well-fixed TKAs treated at the study institution between January 2011 and December 2019 were identified from admission lists and operating lists. Patients with bilateral simultaneous fractures, the second of bilateral sequential fractures, intraoperative periprosthetic fractures and fractures that were not treated with LLP fixation were excluded. All patients in the study population underwent internal fixation with an LLP +/− augmentation, performed by one of eight specialist orthopaedic trauma surgeons.
A PDFF was defined as suitable for fixation by the operating surgeon when the TKA femoral component was well fixed with sufficient bone in the distal fragment to receive five locking screws through an LLP. A Periloc (Smith & Nephew, Watford) LLP was placed using a minimally invasive, direct lateral or lateral parapatellar approach. Additional fixation with cables, lag screws or dual plating was performed at the surgeon’s discretion, according to fracture configuration. Locking screws were used distally and non-locking screws were used proximally, typically via the targeting device. Postoperative weight-bearing restrictions were prescribed at the discretion of the operating surgeon. Patients were prescribed either immediate and unrestricted weight-bearing as tolerated (WBAT) or 6 weeks of RWB, which included instructions for either partial, toe-touch or non-weight-bearing. Patients were mobilized from the first postoperative day or when medically fit. Mobilization proceeded from hoist to gutter frame to zimmer frame to walking sticks or crutches, according to patient ability, under the supervision of physiotherapists, occupational therapists and nurses. Patients in the RWB group did not progress beyond their prescribed restriction. Patients in the WBAT group progressed as their symptoms and ability allowed.
Electronic patient records and operation notes were examined and the following data recorded: demographic data, body mass index (BMI), date of primary prosthesis, date of injury, osteoporosis, bisphosphonate use, details of operative management, weight-bearing restrictions and complications (early < 6 weeks and late > 6 weeks). Details of the surgical approach and fixation construct were recorded (plate type and configuration, plate length, working length, cable use and proximal screw number). Functional mobility status was recorded pre fracture and at discharge. A score was assigned from 0 (full independent activity) to 5 (bedridden) [25]. The acute length of stay and discharge destination were determined. Clinical follow up was performed at 6–8 weeks. Further clinical follow up was at the surgeon’s discretion. Mortality was calculated at 30 days, 90 days and 1 year. Modes of surgical management failure were determined and details of reoperation were recorded.
Radiographic review was performed independently by two orthopaedic surgeons (CEHS and OJFK), using the picture archiving and communication system (PACS; Kodak Carestream, Rochester, NY, USA). Fractures were classified using the Su classification [26]. Interprosthetic fractures were noted. The fixation construct was recorded (LLP length, dual plates, lag screws, cerclage cables and proximal screw number). The presence of medial comminution and the quality of reduction were recorded and any malreduction deformity was noted. Anatomic reduction was defined as anatomic restoration of alignment and translation in coronal and sagittal planes. All subsequent radiographs were reviewed in the national PACS archive to identify any subsequent fixation failure or revision surgery that may have occurred outside our institution but within Scotland.
Statistical analysis
Data were analysed using SPSS version 25.0. Univariate analysis was performed using parametric (unpaired Student’s t test) and non-parametric (Mann–Whitney U test) tests as appropriate to assess continuous variables for significant differences between the RWB and WBAT groups. Nominal categorical variables, such as revision and reoperation, were assessed using the chi-squared or Fisher’s exact test. p ≤ 0.05 was considered statistically significant. Kaplan–Meier analysis survival analysis was undertaken, using the end point of reoperation for any reason. The log-rank statistic was used to compare the two weight-bearing strategies. Cox multivariable regression analysis was performed to identify risk factors for reoperation, using the following covariates: age at fracture, postoperative weight-bearing restriction, Su classification, medial comminution, anatomic reduction obtained, residual golf-club deformity, dual plating and cable use. A power calculation suggested that a sample size of 42 would detect a 3.8× increase in reoperation rate from a baseline of 10% [10, 20], as significant with 80% power and α = 0.05.
Results
From January 2011 to December 2019, 47 PDFFs involving TKAs occurred in 43 patients and were treated with LLP fixation. The second fractures of bilateral sequential fractures were excluded, leaving a study population of 43 PDFFs in 43 patients. The fractures occurred at a mean of 9.5 years (SD 3.6, range 0–21) after primary TKA, which incorporated a non-stemmed primary femoral component in 41 cases (95.3%) and a hinged knee prosthesis with femoral and tibial stems in 2 cases (4.6%). Seven (16.2%) fractures were interprosthetic. An LLP was used in isolation in 22/43 patients (51.2%) and was augmented by cables in 13/43 (30.2%), by lag screws in 3/43 (7.0%) and by a medial plate (dual plating) in 5/43 (11.6%). In 14/43 cases (32.6%), a minimally invasive approach was used. The mean length of follow-up was 3.6 years (SD 2.8, range 1.0–9.1).
Weight-bearing status
Postoperatively, immediate WBAT was prescribed in 28/43 (65.1%) patients and RWB in 15/43 (34.9%). The patients’ demographic and clinical characteristics are detailed in Table 1. These did not differ between the WBAT and RWB groups, other than a higher frequency of patients with interprosthetic fractures in the RWB group: 5/15 (33.3%) RWB patients had interprosthetic fractures, compared with 2/28 (7.1%) in the WBAT group (p = 0.040, Fisher’s exact test). RWB was prescribed for 6 weeks and included: partial weight-bearing in 5/15 patients; touch weight-bearing in 3/15 patients; and no weight-bearing in 7/15 patients. A hinged knee brace with unrestricted flexion was used in 4/28 patients (14.3%) in the WBAT group and in 1/15 patients (6.7%) in the RWB group.
Table 1.
Variable | WBAT (n = 28) | RWB (n = 15) | p value |
---|---|---|---|
Age (years) | 83.1 (11.6) | 76.8 (11.1) | 0.092* |
BMI | 26.5 (5.6) | 27.6 (6.1) | 0.591* |
BMI ≥30 | 8 [28.6] | 5 [33.3] | 0.564^ |
Female gender | 24 [85.7] | 13 [86.7] | 0.932^ |
Osteoporosis | 9 [32.1] | 2 [13.3] | 0.273^^ |
Bisphosphonates | 4 [14.2] | 1 [6.7] | 0.639^^ |
Pre-fracture functional mobility scale | |||
0 - Full activity | 9 [32.1] | 6 [40.0] | 0.771^ |
1 - Walking with assistance | 8 [28.6] | 5 [33.3] | |
2 - Walking with assistance for short periods only | 4 [14.3] | 3 [20.0] | |
3 - Walking with assistance for ADLs/appointments only | 2 [7.1] | 0 | |
4 - Confined to a wheelchair | 1 [3.6] | 0 | |
5 - Bedridden | 1 [3.6] | 0 | |
Fracture features | |||
Su classification | 0.891 | ||
I | 6 [21.4] | 4 [26.7] | |
II | 17 [60.7] | 8 [53.3] | |
III | 5 [17.9] | 3 [20.0] | |
Medial comminution | 4 [14.3] | 5 [33.3] | 0.238^^ |
Interprosthetic | 2 [7.1] | 5 [33.3] | 0.040^ |
Time since TKA (years) | 10.4 (5.7) | 7.6 (4.5) | 0.124* |
Surgical parameters | |||
Time to surgery (days) | 3 | 2 | 0.238** |
Anatomic reduction | 19 [67.9] | 9 [60.0] | 0.606^ |
Golf-club deformity | 3 [10.7] | 2 [13.3] | 1.00^^ |
Cables | 8 [28.6] | 7 [46.7] | 0.235^ |
Dual plating | 3 [10.7] | 2 [13.3] | 1.00^^ |
Open approach | 13 [46.4] | 9 [60.0] | 0.755^ |
Data presented as mean (SD) or number [%]
BMI body mass index, RWB restricted weight-bearing, TKA total knee arthroplasty, WBAT weight-bearing as tolerated
* Unpaired T-test
** Mann Whitney U test
^ Chi square
^^ Fisher's exact
Primary outcome measure: reoperations
During the study period, eight patients (18.6%) underwent reoperation for any reason. This did not differ significantly between the WBAT (6/28) and RWB (2/15) groups (p = 0.69, Fisher’s exact test). The indications for reoperation are presented in Table 2, along with the fixation construct employed and the assumed mode of failure (Fig. 1). The relative risk of reoperation in the WBAT group, compared with the RWB group, was 1.03 (95% CI 0.61–1.74; p = 0.91). Kaplan–Meier analysis (with the end point of reoperation for any reason) demonstrated no difference in survival between the WBAT and RWB groups at 2 years: 80.6% (95% CI 65.3–95.9) following WBAT, compared with 83.3% (95% CI 62.1–100) following RWB (p = 0.54, log-rank test) (Fig. 2). Brace use was not associated with the reoperation rate: 1/5 brace users required reoperation (p = 1.0, Fisher’s exact test).
Table 2.
Age (years) | Sex | Fracture features | Construct | Reduction | MoF | Cause | Mx |
---|---|---|---|---|---|---|---|
WBAT | |||||||
68 | Female |
Su III Medial comminution |
LLP 13 hole; 5 proximal screws |
Extended | Refracture | New fracture at proximal plate tip | DFR |
87 | Female | Su II |
LLP 8 hole; cables; 4 proximal screws |
Anatomic | NU and plate fracture | Excessive soft tissue stripping | Refix (IMN) |
75 | Female |
Su III Medial comminution |
LLP 13 hole; 4 proximal screws |
Golf-club deformity | Early fixation failure | Coronal plane malreduction, medial comminution | DFR |
79 | Female | Su I |
LLP 8 hole; 3 proximal screws |
Anatomic | Early fixation failure | Inadequate fixation | Refix (LLP) |
83 | Female |
Su II Medial comminution |
LLP and cables | Slight varus | NU and plate fracture | Medial comminution | Refix (dual plating) |
86 | Female | Su II |
LLP 8 hole; 4 proximal screws |
Extended | Infection | Deep infection, tibial collapse | Revision TKA (Total Stabiliser) |
RWB | |||||||
71 | Female |
Su III Interprosthetic Medial comminution |
LLP 13 hole; lag screws; 6 proximal screws |
Golf club, varus | NU and Plate fracture |
Coronal plane malreduction Mixed modes of fixation |
DFR |
75 | Female | Su II |
LLP 13 hole; lag screws; 5 proximal screws |
Anatomic | NU and plate fracture | Mixed modes of fixation | Refix (dual plating) |
0 - Full mobility
1 - Walking with assistance
2 - Walking with assistance for short periods only
3 - Walking with assistance for ADLs/appointments onl
4 - Confined to wheelchair
5 - Bedridden
Secondary outcome measures
Complications and mortality rates are presented in Tables 3 and 4. Ten (23.1%) patients died during follow-up. There were no significant differences in complications, length of acute hospital stay, requirement for rehabilitation, discharge to home and ultimate functional mobility status between groups (Tables 3 and 4). Functional mobility status declined less in the WBAT group, but this was not significant (Table 3, Fig. 3).
Table 3.
Covariate | Hazard ratio (95% CI) | p value |
---|---|---|
Age | 1.01 (0.90–1.12) | 0.912 |
Su III fracture | 5.58 (0.72–43.3) | 0.100 |
Medial comminution | 10.7 (1.45–79.5) | 0.020 |
Anatomic reduction | 0.11 (0.013–0.96) | 0.046 |
Golf-club deformity | 0.28 (0.03–2.59) | 0.264 |
Dual plating | 5.3 (0.12–224.1) | 0.387 |
Cables | 0.80 (0.14–4.50) | 0.800 |
Protected weight-bearing postoperatively | 0.33 (0.05–2.37) | 0.269 |
LLP lateral locking plate
Bold data represent p-value of less than 0.05
Table 4.
Variable | WBAT (n = 28) | RWB (n = 15) | p value |
---|---|---|---|
Complications | |||
Early medical (<6 weeks) | 17 [60.7] | 9 [60.0] | 0.850^ |
Early surgical (<6 weeks) | 5 [17.9] | 0 | 0.076^ |
Mortality | |||
30 days | 2 [7.1] | 0 | 0.535^^ |
90 days | 2 [7.1] | 2 [13.3] | 0.602^^ |
1 year | 4 [14.2] | 2 [13.3] | 1.0^^ |
Failures | |||
Reoperations | 6 [21.4] | 2 [13.3] | 0.692^^ |
Non-union | 2 [7.1] | 2 [13.3] | 1.0^^ |
Fixation failure | 2 [7.1] | 0 | 0.535^^ |
Mobility | |||
Post-fracture FMS 0 | 3 [10.7] | 1 [6.7] | 0.623^ |
1 - Full activity | 8 [28.6] | 3 [20.0] | |
2 - Walking with assistance for short periods only | 5 [17.9] | 4 [26.7] | |
3 - Walking with assistance for ADLs/appointments only | 2 [7.1] | 3 [20.0] | |
4 - Confined to wheelchair | 2 [7.1] | 0 | |
5 - Bedridden | 2 [7.1] | 2 [20.0] | |
Functional mobility change | −0.67 (1.3) | −1.46 (1.3) | 0.083* |
Disposition | |||
Length of acute stay | 13 | 10 | 0.265** |
Required period of rehabilitation | 12 | 8 | 0.651^ |
Ultimate discharge destination | 0.841^ | ||
Own home | 10 [35.7] | 6 [40.0] | |
Care home | 4 [14.3] | 1 [6.7] | |
Community hospital | 2 [7.1] | 0 | |
Died in hospital | 1 [3.6] | 1 [6.7] | |
Unknown after rehabilitation | 10 [35.7] | 6 [40.0] |
Data presented as number [%]
LLP lateral locking plate, PDFF periprosthetic distal femoral fracture, RWB restricted weight-bearing, WBAT weight-bearing as tolerated
* Unpaired T-test
** Mann Whitney U test
^ Chi square
^^ Fisher's exact
Regression analysis
Cox multivariable logistic regression analysis was performed for the end point of reoperation for any reason (Table 5). Patient weight and BMI were not included as these data were missing for six patients and resulted in a model of insufficient significance (p = 0.24). Cox multivariable logistic regression analysis (p = 0.026) identified medial comminution as an independent predictor of reoperation following plate fixation of PDFFs (hazard ratio 10.7, 95% CI 1.5–80; p = 0.020) (Fig. 1). Anatomic reduction was an independent predictor of decreased risk of reoperation (hazard ratio 0.11, 95% CI 0.013–0.96; p = 0.046). Postoperative weight-bearing restrictions were not significantly associated with altered risk of reoperation (hazard ratio 0.33, 95% CI 0.05–2.4; p = 0.27).
Table 5.
Complication | WBAT (n = 28) | RWB (n = 15) | p value |
---|---|---|---|
Early surgical | 0.076a | ||
Another fracture | 1 [3.6] | 0 | |
Cellulitis | 1 [3.6] | 0 | |
Deep infection | 1 [3.6] | 0 | |
Fixation failure | 2 [7.1] | 0 | |
Early medical | 0.850a | ||
AF | 0 | 1 [6.7] | |
AKI | 2 [7.1] | 1 [6.7] | |
Anaemia | 1 [3.6] | 2 [13.3] | |
Electrolyte abnormality | 1 [3.6] | 0 | |
MI | 2 [7.1] | 0 | |
Pneumonia | 6 [21.4] | 0 | |
Sepsis | 1 [3.6] | 0 | |
UTI | 2 [7.1] | 4 [26.7] | |
VTE | 0 | 1 [6.7] | |
Wound infection | 1 [3.6] | 0 | |
Late surgical | 0.576a | ||
Another fracture | 1 [3.6] | 1 [6.7] | |
Aseptic loosening | 1 [3.6] | 0 | |
Deep infection | 0 | 1 [6.7] | |
Fixation failure | 2 [7.1] | 0 | |
NU and plate fracture | 2 [7.1] | 2 [13.3] | |
Wound infection | 0 | 1 [6.7] |
Data presented as number [%]
AF atrial fibrillation, AKI acute kidney injury, MI myocardial infarction, NU non-union, RWB restricted weight-bearing, UTI urinary tract infection, VTE venous thromboembolism, WBAT weight-bearing as tolerated
aChi-square test
Discussion
In the current study, immediate unrestricted weight-bearing following LLP fixation of PDFFs was not associated with an increased risk of fixation failure or reoperation compared with 6 weeks of RWB. The presence of medial comminution was identified as an independent risk factor for reoperation and anatomic reduction was associated with a reduced risk. Of eight reoperations, two were for early fixation failure in the WBAT group and both were attributable to other mechanical failures: coronal plane malreduction with medial comminution in one case; and insufficient proximal fixation (three proximal bicortical screws) in the other. RWB does not appear necessary in these frail older patients, when an LLP plate is used, provided an anatomic reduction is obtained and held with sufficient fixation. We recommend adequate proximal fixation be obtained in all cases with five bicortical screws [27] and that medial comminution is augmented with additional fixation.
A number of studies have investigated the role of LLP fixation in the management of PDFFs [10, 17, 18, 20, 28–30]. Over the past decade, surgeons have gained experience with the LLP technique and its augmentation, and surgical outcomes have generally improved: non-union rates have fallen from 24% [18] to approximately 10% in published series [10, 20]. Although some centres are increasingly prescribing unrestricted weight-bearing in older patients after extra-articular native distal femoral fractures [5, 23], this has not been the case in modern published series of PDFFs, where all have imposed some weight-bearing restrictions after LLP fixation [9, 10, 20].
Immediate and unrestricted weight-bearing following LLP fixation of distal femoral fractures has been examined by two previous studies [5, 23]. Poole et al. [5] reported that immediate unrestricted weight-bearing after LLP fixation was not associated with failure of fixation, in a study of 122 patients. However, this was not limited to older patients and included predominantly native knees, as opposed to periprosthetic fractures. In a study of 135 patients over 60 years of age with extra-articular native distal femoral fractures, Lieder et al. [23] found no difference in major adverse events (including fixation failure and infection) within 6 months of fixation between patients prescribed immediate WBAT, compared with patients prescribed initial touchdown weight-bearing, with reoperation rates of 11% and 19%, respectively. Although this study included all types of fixation, rather than LLP only, and was not limited to periprosthetic fractures, it seems reasonable to consider PDFFs as similar to extra-articular distal femoral fractures: the femoral component must be well fixed to consider fixation rather than revision and, by definition, there cannot be intra-articular extension. The current study supports this: unrestricted weight-bearing after LLP fixation of PDFFs appears safe, provides adequate reduction and adequate initial fixation is achieved.
Most studies limited to PDFFs have employed weight-bearing restrictions of duration 6–12 weeks [9, 10, 20]. One previous study of 52 patients allowing immediate unrestricted weight-bearing after minimally invasive LLP fixation reported a favourable reoperation rate of 5/54 (9%) [24]. Although this previous study did not include a RWB group for comparison, this reoperation figure compares favourably with both that in the current study and those in studies where weight-bearing restrictions were applied: Lotzien et al. [9] n = 45, reoperation rate 22%; Hoellwarth et al. [10], n = 87, reoperation rate 10%; Ruder et al. [20], n = 35, reoperation rate 6%. Previous studies have demonstrated that imposing weight-bearing restrictions on similar patients is associated with significant morbidity [19, 31]. In the absence of an apparent benefit of weight-bearing restrictions, the current study suggests that weight-bearing should be permitted following LLP fixation of PDFFs.
Medial comminution and non-anatomic reduction were identified as independent predictors of fixation failure and reoperation. This is consistent with previous studies, where medial comminution has been associated with both early failure and non-union [19, 32]. Adequate fixation should be employed to facilitate immediate weight-bearing. This may not always be achievable, for example where femoral stems are present in interprosthetic fractures, but should be the aim. LLP construct stability can be improved by augmentation with additional metalwork, such as dual plating [33] or using a nail-plate construct [33], especially when medial comminution is present. In the current study, the primary LLP fixation device was often augmented with cables and/or dual plating at the discretion of the operating surgeon. Eight surgeons were included; although the influence of the operating surgeon is a source of potential bias in terms of weight-bearing restrictions, the number of surgeons involved may strengthen the generalizability of the results – despite different surgeons and different techniques, the weight-bearing status did not appear to affect fixation failures and the reoperation rate.
In terms of loading the fixation construct, body weight may be relevant, especially in the context of other risk factors for mechanical failure such as medial comminution, suboptimal reductions or more distal fractures. Weight and BMI were not included as covariates in the Cox regression analysis, as these data were absent for six patients and led to a model that was not statistically significant. Although weight-bearing was allowed in the WBAT group, we cannot be sure how much weight patients were actively bearing postoperatively, especially in the early postoperative period (or indeed the time taken until full weight-bearing occurred). However, by not placing any restrictions on patients, patients limit their own weight-bearing to a level that is comfortable and, provided that they have normal sensation, we would suggest that this is safe. This approach appears to be supported by the findings of the current study. The unintended consequence of placing weight-bearing restrictions on frail older patients, who are often cognitively impaired, is that they cannot manage it and so, instead of mobilizing and weight-bearing as they are able, they are not mobilized at all rather than breach their prescription.
The current study has a number of limitations, including its retrospective nature. The study was not randomized and there is substantial potential for selection bias: cases with poorer bone quality and less robust fixation may be more likely to have been prescribed RWB but also be more likely to fail; however, other than the frequency of interprosthetic fractures, no significant difference in baseline characteristics was observed between the two groups. In addition, the patient groups were not of equal size and patient-reported outcomes and quality of life were not assessed. Although increasing in incidence [3–5], PDFFs are not common; it is therefore difficult to power a study adequately from a single centre, and multicentre studies would be desirable. However, it has also been demonstrated that, even with a multicentre design, it may not be feasible to undertake prospective comparative studies for this fracture type within the United Kingdom [34], due to fracture incidence and patient complexity. Although this study may be underpowered, it confirms that, when PDFFs are managed with LLP fixation, unrestricted weight-bearing does not appear to cause catastrophic failure of fixation in these frail older patients. This represents one of the largest series of PDFFs treated with LLPs in the literature. Minimum follow-up was 1 year, which is similar to other studies of PDFFs [10, 20]. This time period can be expected to cover fracture-related complications such as fixation failures and non-union [33], although it is too short to comment on potential longer-term component loosening.
Conclusion
This study of 43 consecutive patients undergoing fixation of PDFFs with LLPs at a single institution did not demonstrate an increased rate of reoperation or fixation failure when early unrestricted weight-bearing was permitted. Consistent with previous studies, almost one in five patients required reoperation, and this was independently predicted by medial comminution and non-anatomic reduction [22]. When medial comminution is present, LLPs should be augmented with additional fixation, for example dual plating or an intramedullary nail, to provide a construct that is rigid enough to facilitate unrestricted weight-bearing in these typically frail and older patients. Where the surgeon is confident in the fixation construct, weight-bearing restrictions appear unnecessary and, given their potential associated morbidity, should be avoided where possible.
Acknowledgements
Not applicable.
Authors’ contributions
OJFK and LR was involved in data collection, data analysis, manuscript preparation and approval. MM was involved in data collection, data analysis and approval. MM was involved in study design, data collection, manuscript preparation and approval. CEHS was involved in the concept, study design, data collection, data analysis, manuscript preparation and approval. The author(s) read and approved the final manuscript.
Funding
No external funding was obtained for this study.
Availability of data and materials
The datasets during and/or analysed during the current study are available from the corresponding author on reasonable request.
Declarations
Ethics approval and consent to participate
Due to the retrospective nature of this study, ethical approval was not required.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.NJR (2020) 17th Annual Report 2020. National Joint Regisrty for England, Wales, Northern Ireland, the Isle of Man and the States of Guernsey. Available at: https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2017th%20Annual%20Report%202020.pdf. Accessed 19 Apr 21.
- 2.Bongaarts J. How long will we live? Popul Dev Rev. 2006;32(4):605–628. doi: 10.1111/j.1728-4457.2006.00144.x. [DOI] [Google Scholar]
- 3.Kurtz S, Ong KL, Lau E, Mowatt F, Halpern H. Projections of primary and revision hip and knee arthoplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–785. doi: 10.2106/00004623-200704000-00012. [DOI] [PubMed] [Google Scholar]
- 4.Jassim SS, McNamara I, Hopgood P. Distal femoral replacement in periprosthetic fracture around total knee arthroplasty. Injury. 2014;45(3):550–553. doi: 10.1016/j.injury.2013.10.032. [DOI] [PubMed] [Google Scholar]
- 5.Poole WEC, Wilson DGG, Guthrie HC, Bellringer SF, Freeman R, Guryel E, Nicol SG. ‘Modern’ distal femoral locking plates allow safe, early weight-bearing with a high rate of union and low rate of failure: five-year experience from a United Kingdom major trauma centre. Bone Joint J. 2017;99-B(7):951–957. doi: 10.1302/0301-620X.99B7.BJJ-2016-0585.R1. [DOI] [PubMed] [Google Scholar]
- 6.Elsoe R, Ceccotti AA, Larsen P. Population-based epidemiology and incidence of distal femur fractures. Int Orthop (SICOT) 2018;42(1):191–196. doi: 10.1007/s00264-017-3665-1. [DOI] [PubMed] [Google Scholar]
- 7.Court-Brown CM, Clement ND, Duckworth AD, Aitken S, Biant LC, McQueen MM. The spectrum of fractures in the elderly. Bone Joint J. 2014;96-B(3):366–372. doi: 10.1302/0301-620X.96B3.33316. [DOI] [PubMed] [Google Scholar]
- 8.Thompson SM, Lindisfarne EA, Bradley N, Solan M. Periprosthetic supracondylar femoral fractures above a total knee replacement: compatibility guide for fixation with a retrograde intramedullary nail. J Arthroplast. 2014;29(8):1639–1641. doi: 10.1016/j.arth.2013.07.027. [DOI] [PubMed] [Google Scholar]
- 9.Lotzien S, Hoberg C, Hoffmann MF, Schildhauer TA. Clinical outcome and quality of life of patients with periprosthetic distal femur fractures and retained total knee arthroplasty treated with polyaxial locking plates: a single-center experience. Eur J Orthop Surg Traumatol. 2019;29(1):189–196. doi: 10.1007/s00590-018-2266-z. [DOI] [PubMed] [Google Scholar]
- 10.Hoellwarth JS, Fourman MS, Crossett L, Goodman M, Siska P, Moloney GB, Tarkin IS. Equivalent mortality and complication rates following periprosthetic distal femur fractures managed with either lateral locked plating or a distal femoral replacement. Injury. 2018;49(2):392–397. doi: 10.1016/j.injury.2017.11.040. [DOI] [PubMed] [Google Scholar]
- 11.National Institute for Clinical Excellence (NICE) (2011) ‘Hip fractures. The management of hip fracture in adults.’ Available at http://guidance.nice.org.uk/CG124/NICEGuidance/pdf/English. Accessed 19 Apr 2021
- 12.BOA Standards for Trauma and Orthopaedics (BOASTs) – the care of the older or frail orthopaedic trauma patient. Available at https://www.boa.ac.uk/standards-guidance/boasts.html. Accessed 19 Apr 2021
- 13.Kubiak EN, Beebe MJ, North KMSHR, Potter MQ (2013) Early weight bearing after lower extremity fractures in adults. J Am Acad Orthop Surg 21(12):727–738 [DOI] [PubMed]
- 14.Malik, A.T., Quatman, C.E., Phieffer, L. S, Ly TV, Khan SN. Incidence, risk factors and clinical impact of postoperative delirium following open reduction and internal fixation (ORIF) for hip fractures: an analysis of 7859 patients from the ACS-NSQIP hip fracture procedure targeted database. Eur J Orthop Surg Traumatol. 2019;29:435–46 [DOI] [PubMed]
- 15.Baer M, Neuhaus V, Pape HC, Ciritisis B. Influence of mobilization and weight bearing on in-hospital outcome in geriatric patients with hip fractures. SICOT-J. 2019;5:4. doi: 10.1051/sicotj/2019005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Farrow L, Hall A, Wood AD, Smith R, James K, Holt G, Hutchison J, Myint PK. Quality of care in hip fracture patients: the relationship between adherence to national standards and inproved outcomes. J Bone Joint Surg Am. 2018;100(9):751–757. doi: 10.2106/JBJS.17.00884. [DOI] [PubMed] [Google Scholar]
- 17.Hassan S, Swamy GN, Malhotra R, Badhe NP. Periprosthetic fracture of the distal femur after total knee arthroplasty; prevalence and outcomes following treatment. J Bone Joint Surg (Br) 2012;94-B(Suppl 24):6. [Google Scholar]
- 18.Ebraheim NA, Liu J, Hashmi SZ, Sochcki KR, Moral MZ, Hirschfield AG. High complication rate in locking plate fixation of lower periprosthetic distal femur fractures in patients with total knee arthroplasties. J Arthroplast. 2012;27(5):809–813. doi: 10.1016/j.arth.2011.08.007. [DOI] [PubMed] [Google Scholar]
- 19.Oldmeadow LB, Edwards ER, Kimmel LA, Kipen E, Robertson VJ, Bailey MJ. No rest for the wounded: early ambulation after hip surgery accelerates recovery. ANZ J Surg. 2006;76(7):607–611. doi: 10.1111/j.1445-2197.2006.03786.x. [DOI] [PubMed] [Google Scholar]
- 20.Ruder JA, Hart GP, Kneisl JS, Springer BD, Karunakar MA. Predictors of functional recovery following periprosthetic distal femur fractures. J Arthroplast. 2017;32(5):1571–1575. doi: 10.1016/j.arth.2016.12.013. [DOI] [PubMed] [Google Scholar]
- 21.Bettin CC, Weinlein JC, Toy PC, Heck RK. Distal femoral replacement for acute distal femoral fractures in elderly patients. J Orthop Trauma. 2016;30(9):503–509. doi: 10.1097/BOT.0000000000000600. [DOI] [PubMed] [Google Scholar]
- 22.Hart GP, Kneisl JS, Springer BD, Patt JC, Karunakar MA. Open reduction vs. distal femoral replacement arthroplasty for comminuted distal femur fractures in the patients 70 years and older. J Arthroplast. 2017;32(1):202–206. doi: 10.1016/j.arth.2016.06.006. [DOI] [PubMed] [Google Scholar]
- 23.Lieder CM, Gaski GE, Virkus WW, Kempton LB. Is immediate weight-bearing safe after single implant fixation of elderly distal femur fractures? J Orthop Trauma. 2021;35(1):49–55. doi: 10.1097/BOT.0000000000001882. [DOI] [PubMed] [Google Scholar]
- 24.Smith WR, Stoneback JW, Morgan SJ, Stahel PF. Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients. Patient Saf Surg. 2016;10(1):26. doi: 10.1186/s13037-016-0114-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Rankin J. Cerebral vascular accidents in patients over the age of 60. Scott Med J. 1957;2(5):200–215. doi: 10.1177/003693305700200504. [DOI] [PubMed] [Google Scholar]
- 26.Su ET, DeWal H, Di Cesare PE. Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg. 2004;12(1):12–20. doi: 10.5435/00124635-200401000-00003. [DOI] [PubMed] [Google Scholar]
- 27.Ross L, Keenan OJF, Magill M, Brennan C, Clement ND, Moran M, Patton JT, Scott CEH (2021) Management of low periprosthetic distal femoral fractures: plate fixation versus distal femoral endoprosthesis. Bone Joint J 103-B(4):635–643 [DOI] [PubMed]
- 28.Steinberg EL, Elis J, Steinberg Y, Salai M, Ben-Tov T. A double-plating approach to distal femur fracture: a clinical study. Injury. 2017;48(10):2260–2265. doi: 10.1016/j.injury.2017.07.025. [DOI] [PubMed] [Google Scholar]
- 29.Meneghini RM, Keyes BJ, Reddy KK, Maar DC. Modern retrograde intramedullary nails versus periarticular locked plates for supracondylar femur fractures after total knee arthroplasty. J Arthroplast. 2014;29(7):1478–1481. doi: 10.1016/j.arth.2014.01.025. [DOI] [PubMed] [Google Scholar]
- 30.Liporace FA, Yoon RS. Nail plate combination technique for native and periprosthetic distal femur fractures. J Orthop Trauma. 2019;33(2):e64–e68. doi: 10.1097/BOT.0000000000001332. [DOI] [PubMed] [Google Scholar]
- 31.Ottesen TD, McLynn RP, Galivanche AR, Bagi PS, Zogg CK, Rubin LE, Grauer JN. Increased complications in geriatric patients with a fracture of the hip whose postoperative weight-bearing is restricted. An analysis of 4918 patients. Bone Joint J. 2018;100-B(10):1377–1384. doi: 10.1302/0301-620X.100B10.BJJ-2018-0489.R1. [DOI] [PubMed] [Google Scholar]
- 32.Peschiera V, Staletti L, Cavanna M, Saporito M, Berlusconi M. Predicting the failure in distal femur fractures. Injury. 2018;49(Suppl 3):S2–S7. doi: 10.1016/j.injury.2018.10.001. [DOI] [PubMed] [Google Scholar]
- 33.Füchtmeier B, Galler M, Müller F. Mid-term results of 121 periprosthetic femoral fractures: increased failure and mortality within but not after one postoperative year. J Arthroplast. 2015;30(4):669–674. doi: 10.1016/j.arth.2014.11.006. [DOI] [PubMed] [Google Scholar]
- 34.Hull PD, Chou DTS, Lewis S, Carrothers AD, Queally JM, Allison A, Barton G, Costa ML. Knee Fix or Replace Trial (KFORT): a randomized controlled feasibility study. Bone Joint J. 2019;101-B(11):1408–1415. doi: 10.1302/0301-620X.101B11.BJJ-2019-0370.R2. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The datasets during and/or analysed during the current study are available from the corresponding author on reasonable request.