New Technologies for Detection and Management of Atrial Fibrillation

Adel Khalifa Sultan Hamad 1,
PMCID: PMC8260036  PMID: 34249609

Abstract

Atrial fibrillation (AF) is a common and prevalent form of arrhythmia. It is associated with various morbidities with stroke being the major hazard. Since AF is often reported to be asymptomatic, many individuals remain unaware of their condition and may not receive the requisite treatment. Hence, screening for AF has gained substantial attention recently. Growing advancement in technology has paved way for numerous approaches for AF screening using medical-prescribed devices as well as consumer electronic devices. However, there still lies scope for large-scale randomized trials which would explore additional aspects associated with AF. This review very concisely summarizes AF, screening, present technology, current literature and clinical studies associated with it.

Keywords: Atrial fibrillation, Medical devices, Stroke, Technology

1. Introduction

A trial fibrillation (AF) is the most common and prevalent form of cardiac arrhythmia. It is widely associated with varied consequences from impairment of quality of life to substantial complications such as heart failure, vascular dementia, stroke, enhanced risk of thromboembolic events, depression and mortality [1]. AF as defined by European Society of Cardiology (ESC) Guidelines 2020, is ‘supraventricular tachyarrhythmia with uncoordinated atrial electrical activation and consequently ineffective atrial contraction’ [2]. This hemodynamic instability of AF depends on the interplay of various factors, such as pathophysiological mechanisms, anatomical and electrophysiology associated abnormalities [3,4].

Around 46.3 million individuals were estimated to be suffering from AF according to the Global Burden of Disease project [4]. It has been reported that about one-third of the total AF population is asymptomatic (silent AF) hence awareness and early detection of AF is important. Diagnosis of AF is widely done using an electrocardiogram (ECG) which is the current gold standard for diagnosis. However, early detection of AF is hampered in case of Silent Atrial Fibrillation (SAF) owing to the absence of symptoms and silent nature of rhythm disturbances. Patients with symptomatic AF are furnished with medical attention as a result of symptoms arising due to hemodynamic instability. Whereas, SAF patients may only present after serious complications have taken place such as ischemic stroke or heart failure. Therefore, timely detection of AF is crucial to safeguard patients from the consequences of arrhythmia and progression of AF into fatal conditions [5]. In this review, we summarize the screening for AF detection, newer technologies and clinical studies associated with AF.

2. Screening

Public health screening has enhanced dramatically over the last few years owing to the need and desire to address the growing burden of disease [6]. Advancement in digital technology is highly contributable to this exponential growth. Screening results into detection of disease at its budding stage and treating it at the right time in order to reduce morbidity, mortality and associated healthcare and societal costs [7]. This remarkable shift has derived a more proactive approach whereby early detection of disease has renewed importance over the diagnosis of clinically overt disease. AF screening is considered as one of the best strategies to enhance detection rates in individuals. Population-based AF screening has various benefits, including identification of patients with unrecognized AF who would potentially benefit from oral anticoagulants (OAC) to prevent stroke, as well as the beginning of requisite treatment regimen early in high-risk patients [8]. Different consensus guidelines recommend screening strategies of AF which includes ESC guidelines that recommend opportunistic screening by pulse palpation or ECG in patients aged 65 or older [2]. The National Heart Foundation of Australia, the Cardiac Society of Australia and New Zealand recommend opportunistic point-of-care screening in clinic or community in individuals aged ≥65 years [9]. Over the years, there has been vast progress in the development of diagnostic tools, ranging from devices which detect persistent or paroxysmal AF to devices which offer long-term continuous identification of brief asymptomatic AF [10]. Nowadays, the term ‘Digital Health’ is popularly used to describe the use of digitalization and communication technology to gather and analyze information for improvement of health. This involves electronic health records (EHRs), implantable device monitoring, wearable sensor data, analytics and artificial intelligence (AI), behavioral health, and personalized medicine. Amongst these, mobile health (mHealth) which is a part of digital health is defined by the World Health Organization as health practice supported by mobile devices, such as mobile phones, patient-monitoring devices, personal digital assistants, and other wireless devices [11]. In recent years, these devices have become popular among health-conscious consumers and will continue to rapidly expand. There has been extensive use of cardiac implantable electronic devices (CIEDs) such as permanent pacemakers (PPM), implantable cardioverter defibrillators (ICDs), cardiac resynchronisation therapy (CRT) devices [pacemakers (CRT-P) and defibrillators (CRT-D)] which have resulted in early detection of brief AF asymptomatic episodes. CIEDs with an atrial lead are equipped to detect atrial arrhythmia irrespective of the appearance of symptoms. Implantable cardiac monitors (ICMs) and wearable monitors (wristbands, watches and shirts with imbedded leads/sensors and adhesive patches with sensors worn on the chest) are also being used recently. In case of wearable heart rate devices, subsequent monitoring by ECG is necessary for AF diagnosis to eliminate chances of false positives or artifacts. For devices which offer continuous monitoring, generated data is analyzed and processed by algorithms programmed in the device and utilized by manufacturer for report preparation.

This altogether has resulted into a newer category of atrial arrhythmias called atrial high-rate episodes (AHREs) also known as, subclinical atrial tachyarrhythmias or subclinical AF. AHREs can be defined as the detection of asymptomatic AF episodes by implantable devices and confirmed by electrogram or by review of recorded rhythm on the ECG [12,13]. In case of AF detection using any screening tool such as mobile or wearable device which are capable of ECG recording, a single-lead ECG tracing of ≥30 s also enables direct analysis of results. However, if AF detection is not based on ECG recording (e.g. with devices using photoplethysmography) or in case there is uncertainty about diagnosis and interpretation provided by device ECG, a confirmatory ECG is required with additional ECG recording using a 12-lead ECG or Holter monitor, etc. [2] Screening modalities which detect AF by intermittent assessment of cardiac rhythm include 12-Lead ECG, pulse palpation, smartwatch, smartphone extension and home blood pressure monitor. AF detection by continuous monitoring includes implantable loop recorder, ambulatory patch ECG and multi-lead Holter monitor [8].

3. New device technology for AF detection

With ongoing advancement, there has been the development of a wide range of patient-friendly technology focused on improving the accuracy and detection rates of AF. It ranges from new devices to several applications on smart phones. These devices offer advanced screening along with enhanced specificity and sensitivity. They also offer convenience and ease to patients so that they can self-test with immediate diagnosis of AF if present.

Traditional ambulatory Holter monitors (HM) which are connected by electrodes to the chest, are still regularly used but have several limitations. They can be used for varying lengths of time but can cause inconvenience and difficulty in result analysis [14]. Recently, wrist-worn wearables have accumulated significant attention for AF detection. Smart phones and watches are equipped to capture personalized health data and most commonly used. They can analyze heart rhythm and detect AF using photoplethysmography (PPG). It is an easy, convenient and widely available technology to detect AF in asymptomatic patients [15]. PPG technology is usually more susceptible to motion artefact. The most commonly used smart watches include the Apple Watch and Fitbit [16]. The sensitivity and specificity of PPG technology from various clinical findings was found to be 95–98% and 95–99.6% respectively [17]. Blood pressure monitors offer pulse rhythm detection, making this another technology for AF screening which is cost-effective and easy to use in daily routine. These devices have been used increasingly owing to the prevalence of hypertension [18]. Latest innovations have enabled the recording of electric impulses from the heart without conventional ECG machines. Handheld device or smartphone compatible ECG recorder is wearable, small in size and can record cardiac impulses for extended periods of time [19]. A single lead is used in majority of these devices. One of the best known is AliveCor or Kardia. A summary of clinical findings suggests sensitivity to be 66.7–98.5% and specificity to be 99.4–99% [17]. The generated data is wirelessly transmitted to a smart phone and produces a tracing. The limiting factors include requiring access to smartphone, not recommended for use in children and those with implanted electronic devices [19,20]. A simple alternative to Holter or loop recorders for AF screening are Patch ECG monitors. Though the ‘gold standard’ for assessing abnormalities of cardiac rhythm is 12-lead Holter, there has been an increasing demand for portable devices which allow monitoring of cardiac rhythm in real-world settings such as home or workplace. To facilitate this, patch ECG monitors are designed to be waterproof, having wireless communication and containing patch carrier for skin adhesion [21]. Amongst wearable devices, as of now, adhesive patches are mostly used for detection of AF in an embolic stroke of undetermined source (ESUS) or evaluating AF burden after invasive interventions. Nevertheless, consumer-grade devices exhibit good potential for AF detection outside the traditional medical settings, their accountability and performance in AF detection is currently uncertain. Interpretation and management of patients on its basis is yet to be established concretely (Table 1) [22,23].

Table 1.

Technology used for atrial fibrillation detection.

Type of technology Device Functioning Advantages Disadvantages Performance
Photoplethysmography:
  • - Wristband-type

  • - Forehead-type

  • - Ear-type

Apple watch
Fitbit
Simband
HuaweiB and 2
GearFit2
CardioSense
Utilizes infrared light to measure the volumetric variations of blood circulation. This information is then analyzed by an algorithm in the device and the user is notified [22,32]
  • - Low-cost

  • - Non-intrusive modality for continuous heart rate monitoring

  • - Recognizing arrhythmia in a PPG signal can be challenging in the presence of motion artifacts [33]

  • - Positive predictive value of AppleWatch notification and tachogram was 84% and 71% respectively [26].

  • - DETECT AF PRO reported sensitivity of 91.5% and specificity of 99.6% for AF detection by photoplathysmography [34].

Blood pressure monitor Omron
HealthSense
Beurer
Rossmax
Microlife
WatchBP Home-A
Detects vibrations produced in the arterial wall as a result of blood flow between systolic and diastolic pressures and its transduction into electrical signals [35]
  • - Reliable screening tool in the elderly

  • - Widely available

  • - Paroxysmal AF might also be detected [36]

  • - Irregular heart-presumed AF

  • - WatchBP reported AF detection sensitivity of 95% and specificity of 86% [37].

Handheld device or smartphone compatible ECG recorder Kardia Mobile by AliveCor Zenicore EKG Presence of electrodes which transmit ECG rhythms to smartphone [19]
  • - Good diagnostic accuracy

  • - Ease of use

  • - Short ECG duration

  • - Kardia reported a sensitivity of 98.5% and specificity of 91.4% for diagnosis of AF [38].

Patch ECG monitors ZioPatch
MCOT Patch
BodyGuardian-Heart
BodyGuardian-MINI
Nuvant MCT-Monitor
Carnation
Ambulatory
Monitor
Cardiodiagnostics
MCT
Involves processing of analog and digital ECG data and its transmission to smart phone or computer [21]
  • - Water proof

  • - Patient friendly

  • - Continuous monitoring for up to 14 days

  • - Skin irritation

  • - Single-channel ECG

  • - A pilot study of Zio patch with 75 participants (≥55 years old) with ≥2 AF risk factors reported new silent AF in 5.3% [39].

ECG- Electrocardiography, PPG- Photoplethysmography.

4. Clinical trials

There has been a rapid development in mobile health technologies for detection of AF (Table 2). Currently, there are >100,000 mobile health apps available and >400 wearable monitors [24]. Since the majority of these devices are not clinically validated, caution is needed in their clinical use. Different studies evaluated detection of AF using smart-watches. The Apple Heart Study [25,26], over a period of eight months recruited 419,297 smart-watches users in the United States of America (USA). It was observed that 0.5% of participants received notification of an irregular pulse. Amongst them, upon subsequent ECG patch readings, 34% of participants had atrial fibrillation. The Huawei Heart study [27] included 187, 912 individuals, of which, 0.23% received notification for suspected AF. Out of those who were effectively followed up, 87% of individuals were confirmed as having AF. The SEARCH-AF trial was a randomized, open-label, parallel-group study with 336 patients randomized to receive either 30 days of continuous ECG monitoring (n = 163) or usual care (n = 173). All patients were followed up for a period of 9 months. It was found that AF was detected ten times higher in the monitoring group than those who received usual care [28]. The Cryptogenic Stroke and Underlying AF (CRYSTAL-AF) was a randomized (1:1 ratio), parallel-group trial of 441 patients comparing time to detect AF with an insertable cardiac monitor (ICM) versus conventional follow-up in patients with cryptogenic stroke or transient ischemic attack (TIA). Upon 12 months, it was observed that in ICM group, AF had been detected in 12.4% of patients versus 2.0% patients in the control group. This concludes that ECG monitoring with an ICM was found to be superior to conventional follow-up for detecting AF post cryptogenic stroke [29].

Table 2.

Studies on devices used for atrial fibrillation screening.

Study name Country Number of patients Status Modality Outcomes
Photoplethysmography
Apple Heart Study [25,26] USA 419,297 Completed Wrist-type PPG 34% diagnostic yield of AF; 71% patients detected with simultaneous AF during irregular tachogram
Huawei Heart study [27] China 187, 912 Completed Wrist-type PPG New atrial fibrillation Detection
Rate- 0.23% abnormal pulse notification; 0.12% (confirmed AF)
Fitbit Heart Study [40] USA 100,000 Ongoing Wrist-type PPG New onset AF
Patch Monitor
mSToPS [41] USA 2659 Completed Zio patch monitor New AF Detection Rate-screened period (3.9%); unscreened period (0.9%)
SCREEN-AF [42] Canada 856 Recently completed - Zio patch monitor,
- Watch BP oscillometric device
Detection of new atrial fibrillation or flutter
GUARD-AF [43] USA 52,000 Ongoing Zio patch monitor Stroke, major bleeding
Single-Lead Handheld ECG
Engdahl et al. [44] Sweden 848 Completed – 12-lead ECG
- Single lead handheld ECG
New AF Detection Rate- Initial
Assessment (1.0%); 3.5% (2 wk)
Lowres et al. (SEARCH-AF) [38] Australia 1000 Completed Single-lead handheld ECG New AF Detection Rate-1.5%
Kearley et al. [45] United Kingdom 1000 Completed - Single-lead handheld ECG
- Blood pressure monitor
New AF Detection Rate-1.4%
STROKESTOP [46] Sweden 7173 Completed – 12-lead ECG
- Single lead handheld ECG
New AF Detection Rate- 0.5% (initial assessment); 3% (2 wk)
Kaasenbrood et al. [47] Netherlands 3269 Completed Single-lead handheld ECG New AF Detection Rate-1.1%
Chan et al. [48] Hong Kong 13,122 Completed Single-lead handheld ECG New AF Detection Rate-0.8%
PIAAF-Pharmacy Study [49] Canada 1145 Completed Single-lead handheld ECG New AF Detection Rate-2%
Chan et al. [50] Hong Kong 5969 Completed - Single-lead handheld ECG
- Blood pressure monitor
New AF Detection Rate-1.2%
Quinn et al. [51] Canada 2171 Completed - Pulse palpation
- single-lead handheld ECG
- blood pressure monitor
New AF Detection Rate- 0.6%
REHEARSE-AF [52] United Kingdom 1001 Completed Single-lead handheld ECG New AF Detection Rate-3.7%
STROKESTOP II [53] Sweden 28,712 Completed Zenicor single-lead ECG New AF Detection Rate-2.6%
AF-CATCH [54] China 7641 Ongoing AliveCor single-lead ECG New-onset AF
D2AF [55] Netherlands 19,200 Ongoing - My Diagnostick single-lead ECG
- Watch BP oscillometric device
New-onset AF
VITAL-AF [56] United States 35,000 Ongoing AliveCor single-lead ECG New-onset AF
SAFER [57] United Kingdom 120,000 Ongoing Zenicor single-lead ECG Stroke

AF- Atrial Fibrillation, BP- Blood Pressure ECG- Electrocardiography, PPG-Photoplethysmography.

5. Future directions

Digitalization in health technology has revolutionized the concept of health screening. There has been a constant development and increase in the number of new technologies that can be used in screening of AF. Several of these are even beginning to generate a meaningful evidence base. These devices offer advantages like ease of use along with specificity and sensitivity as compared to traditional methods. Available evidence suggests that digital technologies are more accurate for detection of undiagnosed AF in existing device users.

Provided the enhanced smart device ownership rates across the globe, development of applications for AF detection using PPG technology will likely play a large role in coming years. It will likely help patients in identifying AF along with other potential rhythm abnormalities in the future, but at the risk of warranting significant downward testing in healthy population. Additionally, companies are expected to produce more wearables in the future, thus leading to people having access to home monitoring first and then referring to physicians for further investigations. However, it is not well understood whether older adults who are at risk for AF will adhere to mobile or digital technologies. On the contrary, wearable devices are likely to be used majorly by young healthy individuals who might be at very low risk of AF. Therefore, the overall risk of a false positive notification of AF will be higher than the elderly population, who might be less likely to use a smart watch. Furthermore, recent advancements in AF detection technology offers cost-effectiveness and informed preference, as well as equity and screening access to the complete target population [20].

Hence, clinical evidence generated from ongoing multiple clinical trials would be a major help. However, there still needs to be further research proposing different objectives involving these devices. Further studies are also needed comparing different devices to each other, especially in a screening capacity [20,30,31].

6. Conclusions

AF is a common and important health problem with an increase in prevalence over the years. The consequences of undetected AF are wide-ranging from impairment of quality of life to stroke and even death. It is reported that the majority of AF patients suffer from asymptomatic episodes, which is one of the major concerns. To overcome this problem, early detection with the help of screening tools can be considered as the best option. Potential approaches for AF screening are varied with noninvasive methods being the most feasible and highly acceptable by patients. Despite the upcoming trend for AF screening, there lie certain key issues which remain unanswered. These include the type of population to be screened, a device to be used, a methodology for screening, screening duration and AF burden warranting the use of OAC. Currently, there seems less concrete evidence available demonstrating direct improvement in health outcomes in terms of morbidity or mortality based on screening. However, with the emerging user-friendly smart technology and innovations, it is likely that individuals will be able to self diagnose and become aware of their health data. In-depth research is mandatory to determine the best risk stratification tool. Randomized trials with large patient pool, powered endpoints along with analysis of cost-effectiveness will aid in addressing these evidence gaps.

Abbreviations

AF

Atrial Fibrillation

AHRE

Atrial High-Rate Episodes

AI

Artificial Intelligence

BMI

Body Mass Index

CIED

Cardiac Implantable Electronic Devices

CRT

Cardiac Resynchronisation Therapy

DM

Diabetes Mellitus

ECG

Electrocardiogram

EHRs

Electronic Health Records

ESC

European Society of Cardiology

ESUS

Embolic Stroke Of Undetermined Source

HF

Heart Failure

HM

Holter Monitors

ICM

Insertable Cardiac Monitor

MI

Myocardial Infarction

OAC

Oral Anticoagulants

PPG

Photoplethysmography

PPM

Permanent Pacemakers

SAF

Silent Atrial Fibrillation

TIA

Transient Ischemic Attack

Footnotes

Funding

None.

References

  • 1.Gillinov AM, Blackstone EH, McCarthy PM. Atrial fibrillation: current surgical options and their assessment. Ann Thorac Surg. 2002;74(6):2210–7. doi: 10.1016/S0003-4975(02)03977-2. [DOI] [PubMed] [Google Scholar]
  • 2.Hindricks G, Potpara T, Dagres N, Arbelo E, Bax JJ, Blomstro C, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS) Eur Heart J. 2021 Feb 1;42(5):373–498. doi: 10.1093/eurheartj/ehaa612. [DOI] [PubMed] [Google Scholar]
  • 3.Mwansa H, Mazimba S.A review of atrial fibrillation and current therapeutic strategies: Part 1 Prim Care Rep 20192511 10.5005/jp/books/13034_109. [DOI] [Google Scholar]
  • 4.Kornej J, Börschel CS, Benjamin EJ, Schnabel RB. Epidemiology of atrial fibrillation in the 21st century. Circ Res. 2020;127(1):4–20. doi: 10.1161/CIRCRESAHA.120.316340. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Dilaveris PE, Kennedy HL. Silent atrial fibrillation: epidemiology, diagnosis, and clinical impact. Clin Cardiol. 2017;40(6):413–8. doi: 10.1002/clc.22667. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Andermann A, Blancquaert I, Beauchamp S, Déry V. Revisiting Wilson and Jungner in the genomic age: a review of screening criteria over the past 40 years. Bull World Health Organ. 2008;86:317–9. doi: 10.2471/BLT.07.050112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Markides V, Schilling RJ. Atrial fibrillation: classification, pathophysiology, mechanisms and drug treatment. Heart. 2003;89(8):939–43. doi: 10.1136/heart.89.8.939. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Khurshid S, Healey JS, McIntyre WF, Lubitz SA. Population-Based screening for atrial fibrillation. Circ Res. 2020;127(1):143–54. doi: 10.1161/circresaha.120.316341. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Brieger D, Amerena J, Attia J, Bajorek B, Chan KH, Connell C, et al. National heart foundation of Australia and the cardiac society of Australia and New Zealand: Australian clinical guidelines for the diagnosis and management of atrial fibrillation 2018. Heart, lung & circulation. 2018;27(10):1209–66. doi: 10.1016/j.hlc.2018.06.1043. [DOI] [PubMed] [Google Scholar]
  • 10.Freedman B, Camm J, Calkins H, Healey JS, Rosenqvist M, Wang J, et al. Screening for atrial fibrillation: a report of the AF-SCREEN International Collaboration. Circulation. 2017;135(19):1851–67. doi: 10.1161/cir.0000000000000762. [DOI] [PubMed] [Google Scholar]
  • 11.Varma N, Cygankiewicz I, Turakhia M, Heidbuchel H, Hu Y, Chen LY, et al. 2021 ISHNE/HRS/EHRA/APHRS expert collaborative statement on mHealth in arrhythmia management: digital medical tools for heart rhythm professionals: from the international society for holter and noninvasive electrocardiology/heart rhythm society/European heart rhythm association/asia-pacific heart rhythm society. Circulation: Arrhythm Electrophysiol. 2021;14(2):e009204. doi: 10.1161/CIRCEP.120.009204. https://doi:10.1161/CIRCEP.120.009204. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Noseworthy PA, Kaufman ES, Chen LY, Chung MK, Elkind MS, Joglar JA, et al. Subclinical and device-detected atrial fibrillation: pondering the knowledge gap: a scientific statement from the American Heart Association. Circulation. 2019;140(25):e944–63. doi: 10.1161/cir.0000000000000740. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Khan AA, Boriani G, Lip GYH. Are atrial high rate episodes (AHREs) a precursor to atrial fibrillation? Clin Res Cardiol. 2020;109(4):409–16. doi: 10.1007/s00392-019-01545-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Zimetbaum P, Goldman A. Ambulatory arrhythmia monitoring: choosing the right device. Circulation. 2010;122(16):1629–36. doi: 10.1161/CIRCULATIONAHA.109.925610. [DOI] [PubMed] [Google Scholar]
  • 15.Fan YY, Li YG. Diagnostic performance of a smart device with photoplethysmography technology for atrial fibrillation detection: pilot study (Pre-mAFA II registry) 2019;7(3):e11437. doi: 10.2196/11437. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Eerikäinen LM, Bonomi AG, Schipper F, Dekker LR, Vullings R, de Morree HM, et al. Comparison between electrocardiogram-and photoplethysmogram-derived features for atrial fibrillation detection in free-living conditions. Physiol Meas. 2018;39(8):084001. doi: 10.1088/1361-6579/aad2c0. [DOI] [PubMed] [Google Scholar]
  • 17.Lopez Perales CR, Van Spall HGC, Maeda S, Jimenez A, Laţcu DG, Milman A, et al. Mobile health applications for the detection of atrial fibrillation: a systematic review. Europace: Eur Pacing, Arrhythm Cardiac Electrophysiol :J Work Groups Cardiac Pacing, Arrhythm Cardiac Cell Electrophysiol Eur Soc Cardiol. 2021;23(1):11–28. doi: 10.1093/europace/euaa139. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.George J, MacDonald T. Home blood pressure monitoring. Eur Cardiol. 2015;10(2):95–101. doi: 10.15420/ecr.2015.10.2.95. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Bansal A, Joshi R. Portable out-of-hospital electrocardiography: a review of current technologies. J Arrhythm. 2018;34(2):129–38. doi: 10.1002/joa3.12035. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Richardson E, Hall A, Mitchell AR. Screening for atrial fibrillation and the role of digital health technologies. epidemiology and treatment of atrial fibrillation. IntechOpen. 2019:3. doi: 10.5772/intechopen.88660. [DOI]
  • 21.Lobodzinski SS. ECG patch monitors for assessment of cardiac rhythm abnormalities. Prog Cardiovasc Dis. 2013;56(2):224–9. doi: 10.1016/j.pcad.2013.08.006. [DOI] [PubMed] [Google Scholar]
  • 22.Jones NR, Taylor CJ, Hobbs FR, Bowman L, Casadei B. Screening for atrial fibrillation: a call for evidence. Eur Heart J. 2020;41(10):1075–85. doi: 10.1093/eurheartj/ehz834. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lumikari TJ, Putaala J, Kerola A, Sibolt G, Pirinen J, Pakarinen S, et al. Continuous 4-week ECG monitoring with adhesive electrodes reveals AF in patients with recent embolic stroke of undetermined source. Ann Noninvasive Electrocardiol. 2019;24(5):e12649. doi: 10.1111/anec.12649. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Li KHC, White FA, Tipoe T, Liu T, Wong MCS, Jesuthasan A, et al. The current state of mobile phone apps for monitoring heart rate, heart rate variability, and atrial fibrillation: narrative review. JMIR mHealth uHealth. 2019;7(2):e11606. doi: 10.2196/11606. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Turakhia MP, Desai M, Hedlin H, Rajmane A, Talati N, Ferris T, et al. Rationale and design of a large-scale, app-based study to identify cardiac arrhythmias using a smartwatch: the Apple Heart Study. Am Heart J. 2019;207:66–75. doi: 10.1016/j.ahj.2018.09.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Perez MV, Mahaffey KW, Hedlin H, Rumsfeld JS, Garcia A, Ferris T, et al. Large-scale Assessment of a smartwatch to identify atrial fibrillation. N Engl JMed. 2019;381(20):1909–17. doi: 10.1056/nejmoa1901183. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Guo Y, Wang H, Zhang H, Liu T, Liang Z, Xia Y, et al. Mobile photoplethysmographic technology to detect atrial fibrillation. J Am Coll Cardiol. 2019;74(19):2365–75. doi: 10.1016/j.jacc.2019.08.019. [DOI] [PubMed] [Google Scholar]
  • 28.Presented by Dr Subodh Verma at the American heart association virtual scientific sessions. 2020 Nov 16; [Google Scholar]
  • 29.Sanna T, Diener H-C, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med. 2014;370(26):2478–86. doi: 10.1056/NEJMoa1313600. [DOI] [PubMed] [Google Scholar]
  • 30.Ding EY, Marcus GM, McManus DD. Emerging technologies for identifying atrial fibrillation. Circ Res. 2020;127(1):128–42. doi: 10.1161/circresaha.119.316342. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Ioannidis DC, Kapasouri EM, Vassiliou VS. Wearable devices: monitoring the future? Oxf Med Case Rep. 2019;2019(12):492–4. doi: 10.1093/omcr/omz143. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Castaneda D, Esparza A, Ghamari M, Soltanpur C, Nazeran H. A review on wearable photoplethysmography sensors and their potential future applications in health care. Int J Biosens Bioelectron. 2018;4(4):195–202. doi: 10.15406/ijbsbe.2018.04.00125. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Pereira T, Tran N, Gadhoumi K, Pelter MM, Do DH, Lee RJ, et al. Photoplethysmography based atrial fibrillation detection: a review. NPJ Dig Med. 2020;3(1):3. doi: 10.1038/s41746-019-0207-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Brasier N, Raichle CJ, Dörr M, Becke A, Nohturfft V, Weber S, et al. Detection of atrial fibrillation with a smartphone camera: first prospective, international, two-centre, clinical validation study (DETECT AF PRO) Europace: Eur Pacing, Arrhythm Cardiac Electrophysiol :J Work Groups Cardiac Pacing, Arrhythm Cardiac Cell Electrophysiol Eur Soc Cardiol. 2019;21(1):41–7. doi: 10.1093/europace/euy176. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Berger A. Oscillatory blood pressure monitoring devices. BMJ. 2001;323(7318):919. doi: 10.1136/bmj.323.7318.919. [DOI] [Google Scholar]
  • 36.Verberk WJ, Omboni S, Kollias A, Stergiou GS. Screening for atrial fibrillation with automated blood pressure measurement: research evidence and practice recommendations. Int J Cardiol. 2016;203:465–73. doi: 10.1016/j.ijcard.2015.10.182. [DOI] [PubMed] [Google Scholar]
  • 37.Wiesel J, Fitzig L, Herschman Y, Messineo FC. Detection of atrial fibrillation using a modified microlife blood pressure monitor. Am J Hypertens. 2009;22(8):848–52. doi: 10.1038/ajh.2009.98. [DOI] [PubMed] [Google Scholar]
  • 38.Lowres N, Neubeck L, Salkeld G, Krass I, McLachlan AJ, Redfern J, et al. Feasibility and cost-effectiveness of stroke prevention through community screening for atrial fibrillation using iPhone ECG in pharmacies. The SEARCH-AF study. Thromb Haemostasis. 2014;111(6):1167–76. doi: 10.1160/th14-03-0231. [DOI] [PubMed] [Google Scholar]
  • 39.Turakhia MP, Ullal AJ, Hoang DD, Than CT, Miller JD, Friday KJ, et al. Feasibility of extended ambulatory electrocardiogram monitoring to identify silent atrial fibrillation in high-risk patients: the Screening Study for Undiagnosed Atrial Fibrillation (STUDY-AF) Clin Cardiol. 2015;38(5):285–92. doi: 10.1002/clc.22387. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Fitbit Inc. [Accessed 10 January 2021];Fitbit heart study. Available at: https://healthsolutions.fitbit.com/heartstudy-info/
  • 41.Steinhubl SR, Waalen J, Edwards AM, Ariniello LM, Mehta RR, Ebner GS, et al. Effect of a home-based wearable continuous ECG monitoring patch on detection of undiagnosed atrial fibrillation: the mSToPS randomized clinical trial. J Am Med Assoc. 2018;320(2):146–55. doi: 10.1001/jama.2018.8102. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42. [Accessed 10 January 2021];Home-based screening for early detection of atrial fibrillation in primary care patients aged 75 Years and older. Available at: https://clinicaltrials.gov/ct2/show/NCT02392754.
  • 43. [Accessed 10 January 2021];A study to determine if identification of undiagnosed atrial fibrillation in people at least 70 Years of age reduces the risk of stroke (GUARD-AF) Available at: https://clinicaltrials.gov/ct2/show/NCT04126486.
  • 44.Engdahl J, Andersson L, Mirskaya M, Rosenqvist M. Stepwise screening of atrial fibrillation in a 75-year-old population. Circulation. 2013;127(8):930–7. doi: 10.1161/CIRCULATIONAHA.112.126656. [DOI] [PubMed] [Google Scholar]
  • 45.Kearley K, Selwood M, Van den Bruel A, Thompson M, Mant D, Hobbs FDR, et al. Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors. BMJ Open. 2014;4(5):e004565. doi: 10.1136/bmjopen-2013-004565. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Svennberg E, Engdahl J, Al-Khalili F, Friberg L, Frykman V, Rosenqvist M. Mass screening for untreated atrial fibrillation. Circulation. 2015;131(25):2176–84. doi: 10.1161/CIRCULATIONAHA.114.014343. [DOI] [PubMed] [Google Scholar]
  • 47.Kaasenbrood F, Hollander M, Rutten FH, Gerhards LJ, Hoes AW, Tieleman RG. Yield of screening for atrial fibrillation in primary care with a hand-held, single-lead electrocardiogram device during influenza vaccination. EP Europace. 2016;18(10):1514–20. doi: 10.1093/europace/euv426. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Chan PH, Wong CK, Poh YC, Pun L, Leung WWC, Wong YF, et al. Diagnostic performance of a smartphone-based photoplethysmographic application for atrial fibrillation screening in a primary care setting. J Am Heart Assoc. 2016;5(7):e003428. doi: 10.1161/JAHA.116.003428. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49.Sandhu RK, Dolovich L, Deif B, Barake W, Agarwal G, Grinvalds A, et al. High prevalence of modifiable stroke risk factors identified in a pharmacy-based screening programme. Open Heart. 2016;3(2):e000515. doi: 10.1136/openhrt-2016-000515. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Chan P-H, Wong C-K, Pun L, Wong Y-F, Wong MM-Y, Chu DW-S, et al. Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting. BMJ Open. 2017;7(6):e013685. doi: 10.1136/bmjopen-2016-013685. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Quinn FR, Gladstone DJ, Ivers NM, Sandhu RK, Dolovich L, Ling A, et al. Diagnostic accuracy and yield of screening tests for atrial fibrillation in the family practice setting: a multicentre cohort study. CMAJ open. 2018;6(3):E308. doi: 10.9778/cmajo.20180001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Halcox JP, Wareham K, Cardew A, Gilmore M, Barry JP, Phillips C, et al. Assessment of remote heart rhythm sampling using the AliveCor heart monitor to screen for atrial fibrillation: the REHEARSE-AF study. Circulation. 2017;136(19):1784–94. doi: 10.1161/circulationaha.117.030583. [DOI] [PubMed] [Google Scholar]
  • 53.Kemp Gudmundsdottir K, Fredriksson T, Svennberg E, Al-Khalili F, Friberg L, Frykman V, et al. Stepwise mass screening for atrial fibrillation using N-terminal B-type natriuretic peptide: the STROKESTOP II study. EP Europace. 2020;22(1):24–32. doi: 10.1093/europace/euz255. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Wang J-G, Chen Y, Huang Q-F, Li Y, Freedman B. Rationale and design of the randomized controlled trial of intensive versus usual ECG screening for atrial fibrillation in elderly Chinese by an automated ECG system in community health centers in shanghai (AF-CATCH) Cardiovasc Innovat Appl. 2017;2(2):273–7. doi: 10.15212/CVIA.2017.0005. [DOI] [Google Scholar]
  • 55.Uittenbogaart SB, Verbiest-van Gurp N, Erkens PMG, Lucassen WAM, Knottnerus JA, Winkens B, et al. Detecting and Diagnosing Atrial Fibrillation (D2AF): study protocol for a cluster randomised controlled trial. Trials. 2015;16(1):478. doi: 10.1186/s13063-015-1006-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 56.Ashburner JM, Atlas SJ, McManus DD, Chang Y, Lipsanopoulos ATT, Borowsky LH, et al. Design and rationale of a pragmatic trial integrating routine screening for atrial fibrillation at primary care visits: the VITAL-AF trial. Am Heart J. 2019;215:147–56. doi: 10.1016/j.ahj.2019.06.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57. [Accessed 10 January 2021];Screening for atrial fibrillation with ECG to reduce stroke. Available at: http://www.isrctn.com/ISRCTN16939438.

Articles from Journal of the Saudi Heart Association are provided here courtesy of Saudi Heart Association

RESOURCES