Abstract
Purpose
Cerebral blood flow (CBF) needs to be precisely controlled to maintain brain functions. While previously believed to be autoregulated and near constant over a wide blood pressure range, CBF is now understood as more pressure passive. However, there are still questions regarding the integrated nature of CBF regulation and more specifically the role of cardiac output. Our aim was, therefore, to explore the effects of MAP and cardiac output on CBF in a combined model of reduced preload and increased afterload.
Method
16 healthy volunteers were exposed to combinations of different levels of simultaneous lower body negative pressure and isometric hand grip. We measured blood velocity in the middle cerebral artery (MCAV) and internal carotid artery (ICAV) by Doppler ultrasound, and cerebral oxygen saturation (ScO2) by near-infrared spectroscopy, as surrogates for CBF. The effect of changes in MAP and cardiac output on CBF was estimated with mixed multiple regression.
Result
Both MAP and cardiac output had independent effects on MCAV, ICAV and ScO2. For ICAV and ScO2 there was also a statistically significant interaction effect between MAP and cardiac output. The estimated effect of a change of 10 mmHg in MAP on MCAV was 3.11 cm/s (95% CI 2.51–3.71, P < 0.001), and the effect of a change of 1 L/min in cardiac output was 3.41 cm/s (95% CI 2.82–4.00, P < 0.001).
Conclusion
The present study indicates that during reductions in cardiac output, both MAP and cardiac output have independent effects on CBF.
Supplementary Information
The online version contains supplementary material available at 10.1007/s00421-021-04693-6.
Keywords: Blood pressure, Cardiac output, Cerebrovascular circulation, Hypovolemia, Volunteers
Introduction
The brain has a high metabolic rate and limited substrate stores, making regulation of cerebral blood flow (CBF) essential to maintain its functions (Meng et al. 2015; Willie et al. 2014). The main regulators of CBF are believed to be the arterial partial pressure of CO2 (PaCO2), mean arterial pressure (MAP), cerebral metabolism and autonomic nervous system (Willie et al. 2014). Even though still highly influential, Lassen’s presentation of cerebral autoregulation (CA) (Lassen 1959) has been criticized, as the within subject autoregulatory blood pressure range seems to be narrower than previously stated. In addition, the relationship between MAP and CBF seems to be more pressure passive (Numan et al. 2014).
MAP is the product of systemic vascular resistance (SVR) and cardiac output (disregarding right atrial pressure), and one value of MAP can be seen with different combinations of these two factors. Maintaining constant CBF during a reduction in cardiac output would require extracerebral vascular resistance to increase disproportionally to that of the brain, in accordance with the “selfish brain hypothesis” (Hart 2016). However, there is a convincing amount of evidence pointing to a significant effect of cardiac output on CBF, both in disease and in health (Neumann et al. 2019). In healthy volunteers, several studies have reported reduced cerebral blood velocity with reduced cardiac output during simulated hypovolemia such as lower body negative pressure (LBNP) (Zhang and Levine 2007; Tymko et al. 2016; Levine et al. 1994; Ogoh et al. 2005). There seems to be an effect of cardiac output independent of MAP (Ogoh et al. 2005; Meng et al. 2015), and the notion of strict autoregulation has largely been abandoned (Willie et al. 2014).
There may be redundancy in the different mechanisms affecting CBF, and they may use the same vascular effectors. There is a need for studies integrating different stimuli affecting CBF to further elucidate their effects and interactions. We therefore exposed subjects to isometric hand grip (IHG) during different levels of LBNP. LBNP is a model of central hypovolemia, reduced preload and thereby cardiac output as blood is redistributed from the upper to the lower body (Goswami et al. 2019). IHG increases muscle and skin sympathetic nervous activity and thereby MAP and cardiac afterload with sustained submaximal isometric muscle contraction (Seals 1993).
The aim of the present study was to explore the effects and interactions of changes in MAP and cardiac output on CBF by performing simultaneous LBNP and IHG while measuring middle cerebral artery (MCA) blood velocity (MCAV), internal carotid artery (ICA) blood velocity (ICAV) and cerebral oxygen saturation (ScO2). We hypothesized that there would be significant associations both between changes in MAP and CBF, and between changes in cardiac output and CBF.
Methods
Subjects
After regional ethics committee approval (REC South East A, ref. 2017/136) and written informed consent, 16 healthy volunteers > 18 years were included in the study. Exclusion criteria were pregnancy, any condition limiting physical performance or requiring regular medication (contraceptives exempted) or history of any syncope (presumed vasovagal syncope with known precipitating factor exempted). Subjects refrained from caffeine and strenuous physical activity on the day of the experiment. All experiments were performed between 8 a.m. and 4 p.m. The subjects were accustomed with the setup and acclimatized for 20–30 min before the start of the experiment.
Experimental design
The subjects were exposed to stepwise LBNP of 0, 20, 40, 60 and 80 mmHg. Each LBNP level lasted 6 min and started with 2 min stabilization. Thereafter, the subjects were exposed to 2 min of IHG and 2 min of rest. The subjects were randomized to start with IHG or rest at LBNP 0, with alternating order at subsequent LBNP levels (Fig. 1). To get a balanced design, the subjects were block-randomized with block sizes 2 or 4, using the “blockrand” package in R (Snow). LBNP was relieved before completing LBNP 80 if the subjects displayed signs or symptoms of impending circulatory collapse such as a sudden drop in heart rate or blood pressure, light headedness or nausea. Only completed LBNP levels were used in the analysis, i.e. the LBNP level at which decompensation occurred was removed from the analysis.
Interventions and measurements
The subjects were placed in the LBNP chamber (Hisdal et al. 2003) sealed just above the iliac crest. A three-lead ECG was obtained using Bio Amp/ PowerLab (ADInstruments, Bella Vista, Australia) and exported to Lab Chart 8.1.9 (ADInstruments) for calculation of heart rate (HR). Arterial blood pressure waveform was measured with the volume-clamp method on the third finger of the left hand (Nexfin; BMEYE, Amsterdam, The Netherlands) and exported to LabChart where mean arterial pressure (MAP) was calculated as the time-weighted integral. Cardiac stroke volume was measured continuously with suprasternal Doppler (SD-50; Vingmed Ultrasound, Horten, Norway) (Eriksen and Walløe 1990). Velocity–time integrals for each heartbeat were calculated in LabChart and multiplied by left ventricular outflow tract area from echocardiographic measurements obtained in parasternal long-axis to obtain stroke volume. Cardiac output was calculated as the product of stroke volume and heart rate. End-tidal CO2 (ETCO2) was measured by sidestream capnography (Cap10; Medlab medizinische Diagnosegeräte GmbH, Stutensee, Germany), sampled from a loose-fitting facemask offering minimal resistance and added dead-space. Cerebral oxygen saturation (ScO2) was measured using near-infrared spectroscopy (NIRS; Invos 5100C cerebral/somatic oximeter; Somanetics, Troy, MI, USA). Sensors were placed on the left and right forehead and averaged. Data were extracted from the serial output every 7–8 s to software in LabVIEW 14.0 (National Instruments, Austin, TX, USA).
Middle cerebral artery blood velocity
Middle cerebral artery blood velocity (MCAV) was measured using triplex ultrasound (Logiq S8; GE Healthcare, Boston, MA, USA) with a 2 MHz probe over the right temporal window by the same experienced operator. The MCA was identified, and a pulsed Doppler sample volume was placed aiming for a clearly delineated Doppler signal with the lowest possible angle of insonation. The sample volume was not moved through the experiment. The recordings were exported as.avi-files to Brachial Analyzer 6.4.7 (Medical Imaging Application, Coralville, IA, USA) where MCAV was calculated by automatic tracing of the Doppler waveform.
Internal carotid artery blood velocity, diameter and flow
Internal carotid artery blood velocity (ICAV) and diameter was measured using duplex ultrasound (Vivid E9; GE Vingmed, Horten, Norway) with a 9 MHz linear probe by the same experienced operator. ICA was identified by the location of the carotid bifurcation in B-mode and the morphology of the Doppler waveform. A pulsed Doppler sample volume was placed 1.5–2 cm distal to the carotid bifurcation and adjusted for the angle of insonation, which was < 60°. The sample volume was placed in the middle of the vessel and not moved through the experiment (Thomas et al. 2015). The recordings were exported as DICOM-files to EchoPAC 202 (GE Vingmed) where ICAV was calculated by automatic tracing of the Doppler waveform.
Isometric hand grip
IHG was performed by gripping the right hand on a handle displaying the applied force to the subject. Before the experiment, we measured the maximum voluntary contraction force as the average of three repeated attempts. The subjects were instructed to keep 40% of this force during the IHG by reading the display.
Data processing
All analog signals were sampled in LabChart at 1000 Hz. Data for each heartbeat were defined by the ECG RR-interval and exported as.txt-files and handled in R 3.6.1 (R Foundation for Statistical Computing, Vienna, Austria)/ RStudio 1.1.442 (RStudio, Boston, MA, USA) using the “tidyverse” packages (Wickham 2017). Data for MCAV and ICAV were synchronized with beat-by-beat data from LabChart in R/ RStudio. Mean values for periods of 30 s were calculated, trimming the 5% highest and lowest values to remove noise generated by e.g. motion or extrasystoles.
The ultrasound machines only allowed for maximum 4 min continuous recordings. To be able to capture the transition phase with release of IHG in all subjects, we were not able to record both the whole IHG and “rest” sequences. We did therefore not record the first minute of the “rest” sequence. The final analyses included the last minute of the “rest” sequence (two values each of 30 s averages) and the whole 2 min IHG-sequence (four values). As the release of IHG was accompanied by very rapid hemodynamic changes, the transition phases with release of IHG are not included in the present analyses. ICA diameter was measured manually at end-diastole and end-systole 15 s into each 30 s sequence. ICA mean diameter for cross-sectional area estimation was calculated as [(systolic diameter × 1/3) + (diastolic diameter × 2/3)]. ICA blood flow was calculated as [peak envelope velocity/2 × π × (mean diameter/2)2 × 60].
Statistics
Based on previous data, simulations in a linear mixed regression model showed that 12 subjects would detect a Pearson correlation coefficient of 0.4 between blood velocity and MAP with α = 0.05 and (1 − β) = 0.9, assuming all subjects completing all LBNP levels. Because some subjects were assumed to decompensate before completing all LBNP levels, we included 16 subjects.
Associations between the CBF surrogates and the independent variables were examined using a linear mixed effects model with subjects as a random effect using the “lme” function of the “nlme” package in R (Pinheiro et al. 2017). The independent variables were entered as fixed effects. For every CBF surrogate, linear mixed effects analyses were conducted for each independent variable to ensure statistically significant effects before entering them in a multivariable model with an interaction effect. The interaction effect was included to explore possible dependencies between MAP and cardiac output, and removed from the final model unless statistically significant. Model assumptions were checked using histograms, QQ-plots and by plotting standardized residuals vs. fitted values. When LBNP level was entered as a factor, levels were compared using the “glht” function of the “multcomp” package in R (Hothorn et al. 2008) with “single-step” correction for multiple comparisons. Values are mean (SD) unless otherwise stated. P < 0.05 was considered statistically significant. Precision was calculated as 1.96 × √(residual mean square) in a one-way ANOVA with subjects as factors (Bland and Altman 1999).
Results
16 subjects (9 female) with age 24 (3) years, height 177 (11) cm, weight 71 (14) kg and body mass index 23 (3) kg/m2 were included. All subjects completed LBNP 0 and LBNP 20, 15 subjects completed LBNP 40, 11 subjects completed LBNP 60 and two subjects completed LBNP 80. MAP, cardiac output, heart rate, stroke volume, MCAV, ICAV, ScO2 and ETCO2 through the experiment are presented in Fig. 2 and shows the intended increase in MAP with IHG, and reduction in cardiac output with LBNP. The precision of measurement was 4.37 cm/s for MCAV, 4.20 cm/s for ICAV and 0.022 cm for ICA diameter.
Effects on MCAV
Bivariable analyses
The associations between MAP and MCAV, and cardiac output and MCAV, are presented in Fig. 3. In the regression analyses, both MAP and cardiac output were significantly associated with MCAV. The estimated effect of a change of 10 mmHg in MAP on MCAV was 3.43 cm/s (95% CI 2.72–4.13; P < 0.001) (Fig. 3, panel A and Appendix, Regression 1). The estimated effect of a change of 1 L/min in cardiac output on MCAV was 3.69 cm/s (95% CI 3.02–4.36; P < 0.001) (Fig. 3, panel B and Appendix, Regression 2).
Exploration of a possible non-linear relation between MCAV and MAP was explored with polynomial regression, without achieving better model-fit than assuming a linear relationship between MCAV and MAP (Appendix, Regression 20).
Multivariable analyses
When entering both MAP and cardiac output in a multivariable model, an interaction term was not statistically significant (P = 0.067) and removed. The effects of MAP and cardiac output were both significant, with a 10 mmHg change in MAP corresponding to a change in MCAV of 3.11 cm/s (95% CI 2.51–3.71; P < 0.001), and a 1 L/min change in cardiac output corresponding to a change in MCAV of 3.41 cm/s (95% CI 2.82–4.00; P < 0.001) (Appendix, Regression 3).
Although MAP and cardiac output did not seem strongly correlated (Fig. 4), they are mathematically coupled (Archie 1981) through the equation MAP ~ cardiac output × SVR (disregarding central venous pressure). We therefore entered LBNP level as a factor as a proxy for cardiac output in the model, giving significant main effects of both LBNP level and MAP (no interaction effects were statistically significant) (Appendix, Regression 4, Fig. A). In this model, a change of 10 mmHg in MAP corresponded to a change in MCAV of 2.89 cm/s (95% CI 2.35–3.44; P < 0.001).
Effects on ICAV
Bivariable analyses
The associations between MAP and ICAV, and cardiac output and ICAV, are presented in Appendix, Regressions 8 and 9, Figs. D and E. The estimated effect of a 10 mmHg change in MAP on ICAV was 0.88 cm/s (95% CI 0.29–1.46; P = 0.004). The estimated effect of a 1 L/min change in cardiac output on ICAV was 0.83 cm/s (95% CI 0.21–1.44; P = 0.009).
Multivariable analyses
When entering both MAP and cardiac output in a multivariable model, both the main effects and an interaction term were statistically significant. The interaction effect indicated a smaller effect of MAP as cardiac output increased, and vice versa. The results of these regression analyses and estimated effects of each predictor at the 1st, 2nd and 3rd quartile of the other are presented in Appendix, Regression 10.
ICA blood flow
The associations between MAP and ICA blood flow, and cardiac output and ICA blood flow, are presented in Appendix, Regressions 12 and 13, Figs. G and H. ICA diameters were measured in 14 subjects. When entering cardiac output and MAP as explanatory variables in a bivariable analysis, there was a marginal, but statistically significant effect of cardiac output on ICA blood flow. The estimated effect of a change of 1 L/min in cardiac output on ICA blood flow was 11.94 mL/min (95% CI 4.54–19.33, P = 0.002). There was no significant effect of MAP on ICA blood flow. The effects of MAP and cardiac output were similar when entered in a multivariable analysis (Appendix, Regressions 14).
Effects on ScO2
Bivariable analyses
The associations between MAP and ScO2, and cardiac output and ScO2, are presented in Appendix, Regressions 15 and 16, Figs. I and J. The estimated effect of a change of 10 mmHg in MAP on ScO2 was 1.02% (95% CI 0.76–1.27; P < 0.001). The estimated effect of a change of 1 L/min in cardiac output on ScO2 was 0.64% (95% CI 0.34–0.90; P < 0.001).
Multivariable analyses
When entering both MAP and cardiac output in a multivariable model, both the main effects and an interaction term were statistically significant. The interaction effect indicated a smaller effect of MAP as cardiac output increased, and vice versa. The results of these regression analyses and estimated effects of each predictor at the 1st, 2nd and 3rd quartile of the other are presented in Appendix, Regression 17.
MCAV, ICAV and ScO2
MCAV, ICAV and ScO2 were all statistically significantly associated with each other, as presented in Appendix (Regressions 11, 18 and 19, and Figs. F, K and L).
ETCO2
ETCO2 through the experiment is presented in Fig. 2, panel H, and was associated with cardiac output (Appendix, Regression 6 and Fig. C). When entering ETCO2 as an explanatory variable in a multivariable analysis with MAP and cardiac output, there was a statistically significant effect of ETCO2. Also, in this model the effect of cardiac output on MCAV was reduced, but the effect of MAP was practically unaffected (Appendix, Regression 7).
Discussion
The main finding of the present study was that during reductions in cardiac output, both MAP and cardiac output had independent effects on MCAV. Similar effects were found for MAP and cardiac output on ICAV and ScO2.
Autoregulation
Cerebral autoregulation (CA) has long been presented in textbooks as a mechanism to maintain constant CBF despite changes in MAP (Lassen 1959; Numan et al. 2014). This is theoretically compatible with Poiseuille’s law of flow but may in some circumstances require cerebral vascular resistance to act uncoupled from the systemic vascular resistance. If, for example, MAP is mildly reduced due to a large decrease in cardiac output, cerebral vascular resistance would have to decrease as the rest of the body is vasoconstricted.
Anesthesia and critical care may entail large perturbations in both blood pressure and cardiac output, but the overriding treatment goal regardless of clinical condition is to maintain adequate organ perfusion and oxygenation. Although there has recently been some emphasis on the importance of cardiac output (Meng et al. 2015), the focus in the literature is still on MAP presented as the main determinant of an autoregulated cerebral blood flow, albeit with varying lower limits (Brady et al. 2020). Such a system may seem to disregard the complex interplay of the different components of the circulatory system. All organs seem to display some degree of (auto)regulation (Meng et al. 2019), and a reduction in CBF during reduced cardiac output has been found in several studies (Ogoh et al. 2005, 2015; Brown et al. 2003; Ogawa et al. 2007; Bronzwaer et al. 2017). CBF may, however, be on the top of the “regulatory hierarchy”, which is consistent with CBF constituting a higher proportion of cardiac output as cardiac output is reduced (Neumann et al. 2019). We found the estimated relative reduction in MCAV to be only approximately 25% of the reduction in cardiac output, consistent with the brain being given priority. Thus, the textbook presentation of cerebral autoregulation is at least imprecise (Willie et al. 2014), and the notion of a picture-perfect autoregulatory plateau has largely been abandoned. A more complex interplay where different autoregulatory plateaus exist for different levels of cardiac output has been proposed (Meng et al. 2015). Our findings indicate that CBF takes some part in the reduction in global blood flow during hypovolemia, in accordance with such a view, however with a more pressure passive response to MAP. Importantly, regulation of CBF may be influenced by different disease processes and anesthesia. However, the present results fit well with the finding that both the vasopressor phenylephrine and inotrope dobutamine increased graft flow during cerebral bypass surgery (Akkermans et al. 2020).
We have searched for upper and lower limits of autoregulation in our data with polynomial regression models but found the linear relationship to describe the data best. However, although we found a linear relationship between MAP and MCAV, this does not necessitate a totally pressure passive relation, as there may exist “relative autoregulation”. Our estimated relative increase in MCAV was only approximately 50% of the increase in MAP, which implies some degree of regulation in MCAV within our data. Furthermore, there may be steeper relationships (i.e. more pressure passive regions) outside our MAP observations. Some studies have described quite narrow limits of autoregulation (Tan 2012), which could exist within our observed data, but the present study was not designed to look for these.
A statistically significant interaction effect between MAP and cardiac output was found for ICAV and ScO2, however not reaching statistical significance for MCAV. These interaction effects might reflect the redundancy in the regulatory mechanisms for CBF, as the effects of changes in MAP were larger as cardiac output was reduced, and vice versa.
ETCO2
Arterial partial pressure of CO2 (PaCO2) has a strong influence on CBF (Willie et al. 2014). In the present study however, we measured but did not clamp ETCO2. In many studies, ETCO2 is used as a proxy for PaCO2 as the latter requires arterial catheterization and cannot be measured continuously. ETCO2 is typically reduced with LBNP-induced central hypovolemia, which is often interpreted to reflect a reduction in PaCO2. Changes in ETCO2 are, however, associated with changes in cardiac output (Joseph et al. 2003; Lakhal et al. 2017) (Appendix, Fig. C). When we entered ETCO2 as an explanatory variable in the multivariable analysis with MAP, cardiac output and MCAV, the effect of cardiac output was reduced (Appendix, Regression 7). This, along with the close association between cardiac output and ETCO2 (Appendix, Fig C) indicates statistical multicollinearity, and that ETCO2 is redundant in the model when cardiac output is already entered. This further indicates that, in our model, changes in ETCO2 exert little independent effect when changes in cardiac output have been accounted for.
At least three mechanisms could explain a reduction in ETCO2 during hypovolemia: (1) a reduction in PaCO2 due to hyperventilation and/or reduction in peripheral CO2-production, (2) reduced PaCO2 due to sequestering of CO2 in peripheral tissues (decreased wash-out) (Garnett et al. 1989), or (3) reduced pulmonary blood flow, increased dead-space ventilation and increased alveolo-arterial CO2-difference. In the third case, a reduction in ETCO2 does not need to be associated with a reduction in PaCO2. Several studies indicate that this mechanism partly explains the reduction in ETCO2 with experimental (Dubin et al. 2000) and clinical hypovolemia (Campion et al. 2019; Tyburski et al. 2003), questioning the assumption that ETCO2 can substitute PaCO2. This finding is supported by studies applying orthostatic stress, where both LBNP (Zhang and Levine 2007) and head-up-tilt (Immink et al. 2006; Serrador et al. 2006) induced greater reductions in ETCO2 than PaCO2. Also, while controlling for the effect of PaCO2, they found an effect of cardiac output on CBF. A recent study reported stable PaCO2 in the LBNP model (van Helmond et al. 2018). As in other studies, we found a reduction in ETCO2 with increasing hypovolemia. To explore possible mechanisms behind this reduction, we plotted ETCO2 and cardiac output over time at release of LBNP (Appendix, Fig. N). The figure shows that both cardiac output and ETCO2 increase within 5 s, which seems hard to reconcile with mechanism (1), as PaCO2-production would increase much more slowly, and also mechanism (2), as even the wash-out and transport of CO2 from peripheral tissues to the lungs would be expected to take more time than what was observed. Hence, the reduction in ETCO2 in our study seems to be, at least in part, caused by increased alveolar dead-space ventilation. The relationship between ETCO2 and PaCO2 is, however, complicated, and may differ between acute changes and steady-state conditions (Isserles and Breen 1991). It is therefore difficult to state if or to what extent PaCO2 is changed in the present study and it would also question the value of clamping ETCO2. Further studies on the relationship between ETCO2 and PaCO2 in the LBNP model are warranted.
Methodological considerations
As with other studies using transcranial Doppler (TCD) ultrasound, we were not able to measure the diameter of the MCA. Although the diameter is often assumed not to change, it is important to be aware of the fact that small changes in diameter may lead to large changes in flow that we were not able to detect. However, previous studies indicate that the caliber of the MCA remains quite constant during LBNP (Serrador et al. 2000) and blood pressure changes (Giller et al. 1993). The fact that we found a similar effect of cardiac output on CBF when using different methods (i.e. TCD and NIRS) where NIRS is independent of vessel diameter, indicates that the results are valid.
There are also limitations to consider regarding the ICA diameter measurements. As our priority in this study was continuous measurements of blood velocity, we imaged the ICA longitudinally. Hence, in the measurements of diameter, small and undetectable deviations from center may have led to foreshortening, and these results should therefore be interpreted with caution. Imaging the vessel in short axis would have allowed for more reliable measures of diameter but was not compatible with continuous measurements of blood velocity. ICA diameter could not be measured reliably in two subjects. For these reasons, we believe that the ICA diameters and derived blood flow values should be interpreted with caution.
Velocity–time integrals were calculated from the Doppler waveforms using automated software to reduce the risk of bias. These calculations were manually checked and corrected if obviously incorrect, before being accepted into the dataset. All Doppler measurements were performed by the same operators. Precision was calculated at LBNP 0 from the subjects starting without IHG, i.e. half the subjects.
ScO2 measured with NIRS is not a direct measure of CBF and have been shown to be contaminated by extracranial tissues (Davie and Grocott 2012). However, the method has gained popularity in clinical situations where cerebral perfusion may be compromised, and has been suggested as an alternative to transcranial Doppler (Rivera-Lara et al. 2017). We have previously demonstrated that changes in ScO2 seem to reflect changes in cerebral blood flow in the LBNP model (Hisdal et al. 2019). Although extracranial contamination probably affects the results of ScO2 in the present study, they are largely compatible with the results of MCAV and ICAV.
We did not study dynamic CA as we calculated mean values for periods of 30 s for each variable. Traditionally there has been made a distinction between studies on dynamic and static CA. However, this may only reflect the methodology used as there is little evidence for these being different physiological entities (Willie et al. 2014). Also, averaging values over a period of 15–30 s to eliminate the fluctuations caused by respiration is common (Kaur et al. 2018; Serrador et al. 2006; Ogoh et al. 2015; Washio et al. 2018; Tymko et al. 2016).
As seen in Figs. 3a, b, the relationship between MAP and MCAV, and cardiac output and MCAV, varied between subjects. To account for this, we also ran the analyses for MCAV with a random slope (random intercept—random slope model) to account for this difference between subjects. As the results were similar and did not lead to other conclusions, we present the results from our more parsimonious random intercept model.
It would be of potential value to study the isolated effects of changes in MAP and cardiac output at different fixed levels of the other, but we believe this was not feasible in the current model due to the integrated and dynamic nature of the cardiovascular response to the applied stimuli. Although LBNP mainly affects and reduces cardiac output, small changes in MAP may be seen. Conversely, IHG mainly increases MAP but may also slightly increases cardiac output (Stens et al. 2020). The regression models therefore attempt to describe the effect of one variable, controlling for the other. Nonetheless, our conclusions are restricted to the range of observed values during increased MAP and reduced cardiac output. Importantly, the cerebrovasculature seems to buffer increases in MAP better than reductions (Numan et al. 2014).
In conclusion, in a model of simultaneously increased MAP and reduced cardiac output in healthy volunteers, we found independent effects of these variables on MCAV, ICAV and ScO2. These findings support the notion that cardiac output plays a role in CBF regulation, and that there is interplay between MAP and cardiac output.
Supplementary Information
Below is the link to the electronic supplementary material.
Abbreviations
- CA
Cerebral autoregulation
- CBF
Cerebral blood flow
- ETCO2
End-tidal carbon dioxide
- HR
Heart rate
- ICA
Internal carotid artery
- ICAV
Internal carotid artery velocity
- IHG
Isometric hand grip
- LBNP
Lower body negative pressure
- MAP
Mean arterial pressure
- MCA
Middle cerebral artery
- MCAV
Middle cerebral artery velocity
- NIRS
Near-infrared spectroscopy
- PaCO2
Partial pressure of carbon dioxide
- ScO2
Cerebral oxygen saturation
- SD
Standard deviation
- SVR
Systemic vascular resistance
- TCD
Transcranial Doppler
Author contributions
JH and LØH conceived and designed the research. All authors conducted experiments. SLL and LØH analyzed the data. All contributed in the interpretation of the data. SLL and LØH wrote the manuscript. All authors have read and approved the manuscript.
Funding
Open access funding provided by University of Oslo (incl Oslo University Hospital). The study was supported by The Research Council of Norway through the Medical Student Research Program at the University of Oslo and departmental resources.
Code availability
The code used to analyze the data from the current study is available from the corresponding author on reasonable request.
Declarations
Conflict of interest
The authors have no conflicts of interest.
Availability of data and material
The dataset generated during the current study is available from the corresponding author on reasonable request.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- Akkermans A, van Waes JAR, van Doormaal TPC, de Waal EEC, Rinkel GJE, van der Zwan A, Kalkman CJ, van Klei WA. Effects of dobutamine and phenylephrine on cerebral perfusion in patients undergoing cerebral bypass surgery: a randomised crossover trial. Br J Anaesth. 2020;125(4):539–547. doi: 10.1016/j.bja.2020.05.040. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Archie JP., Jr Mathematic coupling of data: a common source of error. Ann Surg. 1981;193(3):296–303. doi: 10.1097/00000658-198103000-00008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135–160. doi: 10.1177/096228029900800204. [DOI] [PubMed] [Google Scholar]
- Brady KM, Hudson A, Hood R, DeCaria B, Lewis C, Hogue CW. Personalizing the definition of hypotension to protect the brain. Anesthesiology. 2020;132(1):170–179. doi: 10.1097/ALN.0000000000003005. [DOI] [PubMed] [Google Scholar]
- Bronzwaer AGT, Verbree J, Stok WJ, Daemen M, van Buchem MA, van Osch MJP, van Lieshout JJ. Aging modifies the effect of cardiac output on middle cerebral artery blood flow velocity. Physiol Rep. 2017 doi: 10.14814/phy2.13361. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brown CM, Dutsch M, Hecht MJ, Neundorfer B, Hilz MJ. Assessment of cerebrovascular and cardiovascular responses to lower body negative pressure as a test of cerebral autoregulation. J Neurol Sci. 2003;208(1–2):71–78. doi: 10.1016/s0022-510x(02)00438-0. [DOI] [PubMed] [Google Scholar]
- Campion EM, Robinson CK, Brant N, Ferrigno L, McIntyre R, Biesterveld B, Alam H, Callcut R, Mishra S, Platt B, Moore MM, Nahmias J, Grigorian A, Dance S, Britton L, Schroeppel T, Rodriquez J, Shatz D, Becker J, Spalding MC, Wolff TW, Privette AR, Eriksson E, Sahi SL, Patel A, Moore SM, Stiles AL, Moore EE, Cohen MJ, Sauaia A, Burlew CC, Urban S, Osi Udekwu P, Nguyen M, Dibbert A, Conroy A, Ross E, Nunez Garcia B, Albertson S, Dunn J, Alnachaoukati O, Stillman Z, Decker C, Heise H, Burton JS. End-tidal carbon dioxide underestimates plasma carbon dioxide during emergent trauma laparotomy leading to hypoventilation and misguided resuscitation: A Western Trauma Association Multicenter Study. J Trauma Acute Care Surg. 2019;87(5):1119–1124. doi: 10.1097/ta.0000000000002469. [DOI] [PubMed] [Google Scholar]
- Davie Sophie N, Grocott Hilary P. Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies. Anesthesiology. 2012;116(4):834–840. doi: 10.1097/ALN.0b013e31824c00d7. [DOI] [PubMed] [Google Scholar]
- Dubin A, Murias G, Estenssoro E, Canales H, Sottile P, Badie J, Baran M, Rossi S, Laporte M, Palizas F, Giampieri J, Mediavilla D, Vacca E, Botta D. End-tidal CO2 pressure determinants during hemorrhagic shock. Intensive Care Med. 2000;26(11):1619–1623. doi: 10.1007/s001340000669. [DOI] [PubMed] [Google Scholar]
- Eriksen M, Walløe L. Improved method for cardiac output determination in man using ultrasound Doppler technique. Med Biol Eng Compu. 1990;28(6):555–560. doi: 10.1007/bf02442607. [DOI] [PubMed] [Google Scholar]
- Garnett AR, Glauser FL, Ornato JP. Hypercarbic arterial acidemia following resuscitation from severe hemorrhagic shock. Resuscitation. 1989;17(1):55–61. doi: 10.1016/0300-9572(89)90079-8. [DOI] [PubMed] [Google Scholar]
- Giller CA, Bowman G, Dyer H, Mootz L, Krippner W. Cerebral arterial diameters during changes in blood pressure and carbon dioxide during craniotomy. Neurosurgery. 1993;32(5):737–741. doi: 10.1227/00006123-199305000-00006. [DOI] [PubMed] [Google Scholar]
- Goswami N, Blaber AP, Hinghofer-Szalkay H, Convertino VA. Lower body negative pressure: physiological effects, applications, and implementation. Physiol Rev. 2019;99(1):807–851. doi: 10.1152/physrev.00006.2018. [DOI] [PubMed] [Google Scholar]
- Hart EC. Human hypertension, sympathetic activity and the selfish brain. Exp Physiol. 2016;101(12):1451–1462. doi: 10.1113/EP085775. [DOI] [PubMed] [Google Scholar]
- Hisdal J, Toska K, Walløe L. Design of a chamber for lower body negative pressure with controlled onset rate. Aviat Space Environ Med. 2003;74(8):874–878. [PubMed] [Google Scholar]
- Hisdal J, Landsverk SA, Hoff IE, Hagen OA, Kirkeboen KA, Hoiseth LO. Associations between changes in precerebral blood flow and cerebral oximetry in the lower body negative pressure model of hypovolemia in healthy volunteers. PLoS ONE. 2019;14(6):e0219154. doi: 10.1371/journal.pone.0219154. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hothorn T, Bretz F, Westfall P. Simultaneous inference in general parametric models. Biom J. 2008;50(3):346–363. doi: 10.1002/bimj.200810425. [DOI] [PubMed] [Google Scholar]
- Immink RV, Secher NH, Roos CM, Pott F, Madsen PL, van Lieshout JJ. The postural reduction in middle cerebral artery blood velocity is not explained by PaCO2. Eur J Appl Physiol. 2006;96(5):609–614. doi: 10.1007/s00421-006-0136-6. [DOI] [PubMed] [Google Scholar]
- Isserles SA, Breen PH. Can changes in end-tidal Pco2 measure changes in cardiac output? Anesth Analg. 1991;73(6):808–814. doi: 10.1213/00000539-199112000-00023. [DOI] [PubMed] [Google Scholar]
- Joseph M, Ziadi S, Nates J, Dannenbaum M, Malkoff M. Increases in cardiac output can reverse flow deficits from vasospasm independent of blood pressure: a study using xenon computed tomographic measurement of cerebral blood flow. Neurosurgery. 2003;53(5):1044–1051. doi: 10.1227/01.neu.0000088567.59324.78. [DOI] [PubMed] [Google Scholar]
- Kaur J, Vranish JR, Barbosa TC, Washio T, Young BE, Stephens BY, Brothers RM, Ogoh S, Fadel PJ. Regulation of regional cerebral blood flow during graded reflex-mediated sympathetic activation via lower body negative pressure. J Appl Physiol. 2018;06:06. doi: 10.1152/japplphysiol.00623.2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lakhal K, Nay MA, Kamel T, Lortat-Jacob B, Ehrmann S, Rozec B, Boulain T. Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge. Br J Anaesth. 2017;118(3):355–362. doi: 10.1093/bja/aew478. [DOI] [PubMed] [Google Scholar]
- Lassen NA. Cerebral blood flow and oxygen consumption in man. Physiol Rev. 1959;39(2):183–238. doi: 10.1152/physrev.1959.39.2.183. [DOI] [PubMed] [Google Scholar]
- Levine BD, Giller CA, Lane LD, Buckey JC, Blomqvist CG. Cerebral versus systemic hemodynamics during graded orthostatic stress in humans. Circulation. 1994;90(1):298–306. doi: 10.1161/01.cir.90.1.298. [DOI] [PubMed] [Google Scholar]
- Meng L, Hou W, Chui J, Han R, Gelb AW. Cardiac output and cerebral blood flow: the integrated regulation of brain perfusion in adult humans. Anesthesiology. 2015;123(5):1198–1208. doi: 10.1097/aln.0000000000000872. [DOI] [PubMed] [Google Scholar]
- Meng L, Wang Y, Zhang L, McDonagh DL. Heterogeneity and variability in pressure autoregulation of organ blood flow: lessons learned over 100+ years. Crit Care Med. 2019;47(3):436–448. doi: 10.1097/ccm.0000000000003569. [DOI] [PubMed] [Google Scholar]
- Neumann S, Burchell Amy E, Rodrigues Jonathan CL, Lawton Christopher B, Burden D, Underhill M, Kobetić Matthew D, Adams Zoe H, Brooks Jonathan CW, Nightingale Angus K, Paton Julian FR, Hamilton Mark CK, Hart Emma C. Cerebral blood flow response to simulated hypovolemia in essential hypertension. Hypertension. 2019;74(6):1391–1398. doi: 10.1161/HYPERTENSIONAHA.119.13229. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Numan T, Bain AR, Hoiland RL, Smirl JD, Lewis NC, Ainslie PN. Static autoregulation in humans: a review and reanalysis. Med Eng Phys. 2014;36(11):1487–1495. doi: 10.1016/j.medengphy.2014.08.001. [DOI] [PubMed] [Google Scholar]
- Ogawa Y, Iwasaki K, Aoki K, Shibata S, Kato J, Ogawa S. Central hypervolemia with hemodilution impairs dynamic cerebral autoregulation. Anesth Analg. 2007;105(5):1389–1396. doi: 10.1213/01.ane.0000281910.95740.e4. [DOI] [PubMed] [Google Scholar]
- Ogoh S, Brothers RM, Barnes Q, Eubank WL, Hawkins MN, Purkayastha S, A OY, Raven PB, The effect of changes in cardiac output on middle cerebral artery mean blood velocity at rest and during exercise. J Physiol. 2005;569(Pt 2):697–704. doi: 10.1113/jphysiol.2005.095836. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ogoh S, Sato K, Okazaki K, Miyamoto T, Hirasawa A, Sadamoto T, Shibasaki M. Blood flow in internal carotid and vertebral arteries during graded lower body negative pressure in humans. Exp Physiol. 2015;100(3):259–266. doi: 10.1113/expphysiol.2014.083964. [DOI] [PubMed] [Google Scholar]
- Pinheiro J, Bates D, DebRoy S, Sarkar D, Team RC (2017) nlme: linear and nonlinear mixed effects models (R package version 3.1-128, 2016). R software
- Rivera-Lara L, Geocadin R, Zorrilla-Vaca A, Healy R, Radzik BR, Palmisano C, Mirski M, Ziai WC, Hogue C. Validation of near-infrared spectroscopy for monitoring cerebral autoregulation in comatose patients. Neurocrit Care. 2017;27(3):362–369. doi: 10.1007/s12028-017-0421-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Seals DR. Influence of force on muscle and skin sympathetic nerve activity during sustained isometric contractions in humans. J Physiol. 1993;462:147–159. doi: 10.1113/jphysiol.1993.sp019548. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Serrador JM, Picot PA, Rutt BK, Shoemaker JK, Bondar RL. MRI measures of middle cerebral artery diameter in conscious humans during simulated orthostasis. Stroke. 2000;31(7):1672–1678. doi: 10.1161/01.str.31.7.1672. [DOI] [PubMed] [Google Scholar]
- Serrador JM, Hughson RL, Kowalchuk JM, Bondar RL, Gelb AW. Cerebral blood flow during orthostasis: role of arterial CO2. Am J Physiol Regul Integr Comp Physiol. 2006;290(4):R1087–1093. doi: 10.1152/ajpregu.00446.2005. [DOI] [PubMed] [Google Scholar]
- Snow G (2013) blockrand: randomization for block random clinical trials (R package version 1.3, 2013)
- Stens NA, Hisdal J, Bakke EF, Kaur N, Sharma A, Stranden E, Thijssen DHJ, Høiseth LØ. Factors mediating the pressor response to isometric muscle contraction: an experimental study in healthy volunteers during lower body negative pressure. PLoS ONE. 2020;15(12):e0243627. doi: 10.1371/journal.pone.0243627. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tan CO. Defining the characteristic relationship between arterial pressure and cerebral flow. J Appl Physiol. 2012;113(8):1194–1200. doi: 10.1152/japplphysiol.00783.2012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thomas KN, Lewis NCS, Hill BG, Ainslie PN. Technical recommendations for the use of carotid duplex ultrasound for the assessment of extracranial blood flow. Am J Physiol Regul Integr Comp Physiol. 2015;309(7):R707–R720. doi: 10.1152/ajpregu.00211.2015. [DOI] [PubMed] [Google Scholar]
- Tyburski JG, Carlin AM, Harvey EH, Steffes C, Wilson RF. End-tidal CO2-arterial CO2 differences: a useful intraoperative mortality marker in trauma surgery. J Trauma. 2003;55(5):892–896. doi: 10.1097/01.Ta.0000097827.51916.7e. [DOI] [PubMed] [Google Scholar]
- Tymko MM, Rickards CA, Skow RJ, Ingram-Cotton NC, Howatt MK, Day TA. The effects of superimposed tilt and lower body negative pressure on anterior and posterior cerebral circulations. Physiol Rep. 2016 doi: 10.14814/phy2.12957. [DOI] [PMC free article] [PubMed] [Google Scholar]
- van Helmond N, Johnson BD, Holbein WW, Petersen-Jones HG, Harvey RE, Ranadive SM, Barnes JN, Curry TB, Convertino VA, Joyner MJ. Effect of acute hypoxemia on cerebral blood flow velocity control during lower body negative pressure. Physiol Rep. 2018 doi: 10.14814/phy2.13594. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Washio T, Vranish JR, Kaur J, Young BE, Katayama K, Fadel PJ, Ogoh S. Acute reduction in posterior cerebral blood flow following isometric handgrip exercise is augmented by lower body negative pressure. Physiol Rep. 2018;6(20):e13886. doi: 10.14814/phy2.13886. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wickham H (2017) tidyverse: easily install and load the 'Tidyverse'. R package version 1.2.1
- Willie CK, Tzeng YC, Fisher JA, Ainslie PN. Integrative regulation of human brain blood flow. J Physiol. 2014;592(5):841–859. doi: 10.1113/jphysiol.2013.268953. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang R, Levine BD. Autonomic ganglionic blockade does not prevent reduction in cerebral blood flow velocity during orthostasis in humans. Stroke. 2007;38(4):1238–1244. doi: 10.1161/01.STR.0000260095.94175.d0. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The code used to analyze the data from the current study is available from the corresponding author on reasonable request.