Abstract
The purpose of the study is to evaluate the risk factors associated with exfoliation in a case-cohort setting and literature review. This single-center, prospective, case-cohort study was carried out from January 2010 to April 2020 on patients operated for cataract surgery by a single surgeon in Lebanon. Forty-nine consecutive patients with exfoliation syndrome (XFS) and 62 consecutive control patients were identified and further investigated for selected systemic (diabetes mellitus, systemic hypertension, asthma, or atopy) and ocular variables (baseline vision, severity of nuclear sclerosis, glaucoma, eye rubbing, history of dry eye, or allergic eye disease). The mean baseline Snellen visual acuity was 20/283 in XFS versus 20/145 in control cases (P = 0.012). XFS also demonstrated significantly denser nuclear sclerosis than controls (P = 0.00958). By univariate analysis, allergic conjunctivitis (15 [30.6%] vs. 2 [3.2%]; P < 0.001), dry eye (20 [40.8%] vs. 13 [21.0%]; P = 0.0133), and habitual rubbing of the eyes (33 [67.3%] vs. 19 [30.6%]; P < 0.001) were associated with the presence of XFS. Habitual ocular rubbing was closely associated with allergic conjunctivitis (odds ratio [OR] = 13.0; 95% confidence interval [CI]: 2.8–58.8; P = 0.032). After multivariable analysis, the following variables showed significant results: glaucoma (OR = 34.5; 95% CI: 4.4–250; P = 0.010), duration of surgery (OR = 5.6; 95% CI 2.43–12.9; P < 0.001), and habitual ocular rubbing (OR = 4.42; 95% CI: 1.97–9.90; P = 0.029). This study shows a novel potential correlation between eye rubbing and XFS in a Lebanese cohort. Chronic eye rubbing induces or may exacerbate preexistent zonular damage in subjects with XFS, hence the need to better manage concurrent ocular surface disorder in these patients.
Keywords: Allergic conjunctivitis, cataract, dry eye, exfoliation syndrome, lens zonules, ocular rubbing, phacoemulsification, pseudoexfoliation syndrome
Introduction
Exfoliation syndrome (XFS) is currently a global disease affecting an estimated 70 million people, worldwide.[1] XFS appears to be a syndrome targeting ocular tissues with deposition of fibrillary material on the lens capsule with similar deposits in other parts of the body, such as the skin, kidneys, liver, heart, and lungs. XFS material is a mixture of several biologic components made of amyloid, laminin, elastic fibers, and collagen basement membrane.[2] The causes of XFS are not well known,[3,4] especially with animal models lacking,[5,6] leaving researchers with the human Tenon's capsule fibroblasts as a model system for the study of XFS.[7] Advanced age appears as a major risk factor as well as some genetic factors.[8] Some evidence exists for the association between XFS and lysyl oxidase-like 1 (LOXL1) protein gene implicated in elastin formation and maintenance and less so with the calcium channel protein gene CACNA1A, and the extracellular matrix chaperon clusterin protein. Known environmental risk factors for the disease have included solar exposure,[9] ambient temperature, living at more northern latitudes,[10] dietary factors,[9,11] and infectious etiology.[12] The possible relationship between XFS and selected ocular and systemic factors was investigated in a Lebanese cohort.
Methods
This is a prospective data registry of all patients undergoing phacoemulsification in one surgical suite by a single surgeon (AMM) from January 2010 to April 2020. All patients provided written informed consent in accordance with the Declaration of Helsinki. Institutional Review Board (Rafic Hariri University Hospital, Beirut, Lebanon) approval was obtained for this study. Data were anonymized to maintain confidentiality. Systemic factors recorded have included age, gender, hypertension, diabetes mellitus, coronary artery disease, morbid obesity, Alzheimer neurodegenerative disorder, and intake of alpha agonists for benign prostatic hypertrophy and any major disease (migraine, cancer). Recorded ocular factors were preoperative and postoperative best-corrected visual acuity (BCVA), intraocular lens power, presence of XFS, glaucoma, macular degeneration, and diabetic retinopathy. Seven hundred and fifteen patients (mean age: 74 years) were enrolled in this study, and 387 of them underwent bilateral cataract removal. Surgeries were performed on 1097 eyes (599 right eyes and 498 left eyes) and were nearly equally distributed among men (509) and women (588). A case–cohort study was designed in which cases with XFS and controls without XFS were drawn from within this large prospective study. We selected a consecutive (most recent to less recent date of surgery) control group. In addition, we conducted a survey on these two groups to collect additional ocular and systemic variables between January 2010 and April 2020 (approved by the Institutional Review Board at Rafic Hariri University Hospital). This survey was done by phone call to answer the presence of habitual ocular rubbing before glaucoma topical therapy, history of therapy for either dry eye or allergic conjunctivitis, skin atopy or asthma, erectile dysfunction, and sensorineural hearing loss. The survey was carried by a blinded operator (KAJ). The subjects who answered positively for ocular rubbing (before glaucoma therapy) were contacted a second time to fill an ocular rubbing score.
We included all patients with significant cataract and visual acuity 20/40 (6/12) or less and with any accompanying ocular morbidity (keratoconus, XFS, glaucoma, maculopathy, reduced endothelial cells [<1800 cells/mm2], and central corneal opacity) or systemic morbidity (controlled diabetes mellitus, controlled systemic hypertension, stable stroke, and controlled angina) and Alzheimer's disease or adult Down's syndrome. Exclusion criteria included refusal to sign an informed consent, recent conjunctivitis of any kind, uncontrolled systemic hypertension or diabetes mellitus, active proliferative diabetic retinopathy, active untreated neovascular macular degeneration, Marfan syndrome, homocystinuria, systemic amyloidosis, true XFS[13] (history of radiotherapy, glass blowing, excessive heat exposure from oven burning or metal welding), and eyes that require concomitant vitrectomy (for vitreous hemorrhage or retinal detachment).
Preoperatively, we carried out slit lamp examination, before and after pupillary dilatation, with one drop of tropicamide (Mydriacyl® 1%, Alcon, Fort Worth, Texas, USA), fundoscopy, tonometry, measurement of BCVA, and ocular measurement with an optical biometer (IOL Master 700; Carl Zeiss Meditec AG, Jena, Germany). Target refraction was emmetropia. In the final analysis, only the first operated eye in subjects with bilateral exfoliation was included. In the control group, the first operated eye of consecutive subjects without XFS was enrolled. BCVA was measured by the same surgeon (AMM) using Snellen visual charts. Nuclear hardness was graded after pupillary dilation on the slit lamp (Haag-Streit® slit lamp 900 [Haag-Streit AG, Koeniz, Switzerland]) by the same surgeon using the 5-level Emery-Little Classification System (soft, semi-soft, medium hard, hard, and rock-hard). Glaucoma diagnosis relied upon intraocular pressure above 21 mmHg, glaucomatous optic disc cupping >0.7, and typical glaucoma-related visual field loss. A rubbing score has been designed to assess numerically the intensity of the ocular friction [Table 1].
Table 1.
Rubbing score is the sum of the items listed (all before initiation of glaucoma eye drops)
| Parameter | Score of 1 | Score of 2 | Score of 3 | Score of 5 |
|---|---|---|---|---|
| Rubbing episode per day | <5/day | 6-10/day | >10/day | |
| Seasonal or yearly rubbing | Occasional | Seasonal | Year round | |
| Rubbing years divided by 5 (years) | 5 | 10 | 15 | 25 |
| Rubbing severity | Mild | Moderate | Severe | |
| Physician noted rubbing before eye exam | X | |||
| Rubbing compulsive or stress-induced | X | |||
| Vernal or allergic conjunctivitis of childhood | X | |||
| Habitual crying | X | |||
| History of drops for ocular allergy | X | |||
| History of drops for dry eye | X | |||
| Rub the skin | X | |||
| Asthma or atopy or allergic rhinosinusitis | X |
Statistical analysis
Statistical analyses were performed using SPSS version 22 (IBM, Chicago, IL, USA), and t-test was used for testing the difference between the means of two independent samples. Multivariate analysis was carried using simple discriminant analysis when the dependent variable is categorical variable broken into yes and no using ANOVA and confirmed by cross-tabulation and Pearson's Chi-square test. Significance is set at P < 0.05.
Literature search
The databases of Medline, Embase and Google Scholar were systematically searched by one of us (AMM) for relevant articles published between 1975 and May 2020 using the search terms: exfoliation or pseudoexfoliation AND risk factors; exfoliation or pseudoexfoliation AND young age and using forward searching, checking references in major reviews (on exfoliation/pseudoexfoliation), and in all retrieved articles. Only comparative studies showing positive results with statistical significance set at P < 0.05 for the associated risk factors were included in the final tabulations.
Results
The number of surveyed patients was 49 in the XFS group and 61 in the control group [Tables 2 and 3]. The completion rate of telephone survey approached 100% as patients or their close relatives (in case of death) completed the survey, for example, the survey in the control group was completed by 57 patients or by their mates in four deceased patients (100% response); likewise, the survey in the XFS group was completed by 45 patients or by their mates in 3 of 4 deceased patients (98% response). All enrolled subjects were Caucasians. The two groups were not different for gender, diabetes mellitus, coronary artery disease, or morbid obesity [Table 2]. XFS patients had longer follow-up because of the need to monitor for future or current glaucoma. XFS group was significantly older (by 7.4 years) than the control group. There was no significant difference for the presence of diabetes mellitus, systemic hypertension, coronary artery disease, morbid obesity, asthma or skin atopy, sensorineural hearing loss, or use of oral alpha-agonist for benign prostatic hypertrophy. Erectile dysfunction occurred in 12 of 22 XFS males (54.5%) versus 3 of 17 control males (17.6%) (P = 0.0069). Additional systemic findings in the XFS group not listed in Table 2 included migraine in 4, rheumatoid arthritis in 3, stroke in 2, and temporal arteritis or sarcoidosis or interstitial lung fibrosis or colon cancer or lung cancer or toxic goiter or Parkinson's or sleep apnea in one case each. Additional systemic findings in the control group included breast cancer in two cases and sleep apnea or carotid stenosis or Parkinson's or migraine in one case each.
Table 2.
Potential systemic risk factors for pseudoexfoliation by univariate analysis
| Mean±SD or total number (%) | P | ||
|---|---|---|---|
| Pseudoexfoliation (n=49) | Control (n=61) | ||
| Age | 78.4±9.0 | 71.0±10.3 | <0.001 |
| Gender | 21 male (42.9) | 25 male (41.0) | 0.42 |
| Diabetes mellitus | 11 (22.4) | 18 (29.5) | 0.20 |
| Systemic hypertension | 18 (36.7) | 29 (47.5) | 0.13 |
| Coronary artery disease | 15 (30.6) | 13 (21.3) | 0.13 |
| Morbid obesity | 2 (4.1) | 2 (3.3) | 0.413 |
| Asthma or atopy | 7 (14.6) | 8 (13.1) | 0.41 |
| Sensorineural hearing loss | 14 (28.6) | 12 (19.7) | 0.14 |
| Erectile dysfunction | 12 (54.5) | 3 (17.6) | 0.0069 |
| Oral alpha agonist intake | 6 (31.2) | 8 (32.0) | 0.45 |
SD: Standard deviation
Table 3.
Potential ocular risk factors for pseudoexfoliation by univariate analysis
| Mean±SD or total number (%) | P | ||
|---|---|---|---|
| Pseudoexfoliation (n=49) | Control (n=61) | ||
| Baseline spectacle corrected visual acuity (logMAR) | −1.13±−0.60 | −0.86±0.70 | 0.032 |
| Final spectacle corrected visual acuity (logMAR) | −0.29±−0.40 | −0.20±0.27 | 0.15 |
| Baseline astigmatism | 1.03±0.69 | 1.19±0.85 | 0.27 |
| Follow-up (months) | 25.5±37.2 | 8.6±18.7 | 0.002 |
| Duration of surgery (min) | 36.0±24.3 | 17.4±6.2 | <0.001 |
| Nuclear sclerosis grade | 3.1±1.3 | 2.4±1.6 | 0.023 |
| Intraocular lens power (D) | 20.4±3.8 | 19.4±4.8 | 0.257 |
| Floppy iris | 2 (4.1) | 9 (14.8) | 0.032 |
| Glaucoma | 18 (36.7) | 1 (1.6) | <0.001 |
| Dry eyes therapy | 21 (42.9) | 13 (21.3) | 0.0074 |
| Allergic conjunctivitis therapy | 17 (34.7) | 2 (4.1) | <0.001 |
| Posterior subcapsular cataract | 0.31±0.71 | 0.21±0.41 | 0.20 |
| Grade 1 | 7 (14.3) | 13 (26.5) | |
| Grade 2 | 1 (2.0) | 0 | |
| Grade 3 | 2 (4.1) | 0 | |
| Nuclear sclerosis grade | 3.10±1.60 | 2.46±2.55 | 0.011 |
| 1 Soft | 5 (10.2) | 15 (24.6) | |
| 2 Semi-soft | 6 (12.2) | 10 (16.4) | |
| 3 Medium-hard | 20 (40.8) | 20 (32.8) | |
| 4 Hard | 12 (24.5) | 11 (18.0) | |
| 5 Rock-hard | 6 (12.2) | 5 (8.2) | |
| Total rub score | 8.69±7.85 | 2.11±4.09 | <0.001 |
| 0-9, 25 (51.0) | 0-9, 53 (86.9) | ||
| >10, 23 (46.9) | >10, 8 (13.1) | ||
Eye-wise, the two groups were not different for baseline astigmatism, presence of posterior subcapsular cataract, baseline refraction (measured indirectly by the inserted intraocular lens power), and final BCVA [Table 3]. The two groups were different in terms of several ocular characteristics. The mean baseline spectacle-corrected Snellen visual acuity was 20/270 in the XFS versus 20/145 in the control (P = 0.032). Duration of surgery was near double in XFS than in controls (36.0 min vs. 17.4 min; P < 0.001), partly from higher grades of severity of nuclear sclerosis in the eyes with XFS (P = 0.023). Glaucoma (18 [36.7%] vs. 1 [16.1%]; P < 0.001), allergic conjunctivitis (before glaucoma therapy) (17 [34.7%] vs. 2 [3.2%]; P < 0.001), dry eye (before glaucoma therapy) (21 [42.9%] vs. 13 [21.0%]; P = 0.0074), and rubbing score of the eyes (before initiation of glaucoma medical therapy) (8.69 vs. 2.11; P < 0.001) were significantly more common in the XFS group. Other ocular findings in six patients with XFS and not listed in Table 2 included: Sjogren's syndrome in 3, chronic anterior blepharitis in 2, severe ocular rosacea in 2, and large old herpetic corneal scar in 1, while a single patient in the control group had chronic anterior blepharitis.
A multiple regression was run to predict the potential risk factors for XFS [Table 4]. These variables significantly predicted the occurrence of XFS (F = 6.68; P < 0.001; R2 = 0.642): duration of cataract surgery (P < 0.001), glaucoma diagnosis (P = 0.004), history of local therapy for allergic conjunctivitis (P = 0.044), and ocular rubbing score (P < 0.001).
Table 4.
Multiple regression analysis of risk factors for pseudoexfoliation
| Variable | P | OR | CIs | |
|---|---|---|---|---|
| Lower | Upper | |||
| Nonocular variables | ||||
| Female gender | 0.843 | 0.90 | 0.50 | 2.31 |
| Older age | 0.001* | 4.02 | 1.80 | 8.96 |
| Diabetes mellitus | 0.404 | 0.90 | 0.43 | 1.98 |
| Systemic hypertension | 0.255 | 0.64 | 0.30 | 1.38 |
| Coronary artery disease | 0.266 | 1.63 | 0.69 | 3.86 |
| Morbid obesity | 0.823 | 1.26 | 0.17 | 9.25 |
| Sensorineural hearing loss | 0.275 | 1.63 | 0.67 | 6.46 |
| Erectile dysfunction | 0.014* | 5.75 | 1.31 | 25.0 |
| Asthma or atopy | 0.825 | 1.13 | 0.38 | 3.38 |
| Use of alpha antagonists | 0.892 | 0.924 | 0.298 | 2.868 |
| Ocular variables | ||||
| Better baseline vision | 0.001* | 0.26 | 0.12 | 0.58 |
| Better final vision | 0.35 | 0.75 | 0.35 | 1.63 |
| Baseline astigmatism | 0.15 | 0.57 | 0.26 | 1.23 |
| Higher nuclear sclerosis severity | 0.039* | 2.40 | 1.03 | 5.57 |
| Posterior subcapsular cataract | 0.91 | 1.05 | 0.42 | 2.63 |
| Higher intraocular lens power | 0.081 | 2.00 | 0.91 | 4.39 |
| Duration of surgery | 0.000* | 5.92 | 2.55 | 13.8 |
| Follow-up (month) | 0.003* | 3.28 | 1.50 | 7.19 |
| Floppy iris | 0.068 | 0.25 | 0.052 | 1.22 |
| Dry eye treatment | 0.015* | 2.77 | 1.20 | 6.37 |
| Allergic eye treatment | 0.000* | 15.6 | 3.40 | 15.6 |
| Glaucoma | 0.000* | 34.5 | 4.44 | 250 |
| Total rub score | 0.000* | 6.12 | 2.64 | 14.2 |
*Significant variables (P<0.05). OR: Odd ratio, CI: Confidence interval
For XFS patients, 48 completed the survey, 30 admitted rubbing, and 18 denied rubbing. Of note, 23 XFS patients were witnessed rubbing the eyes in the clinic (all before any potential therapy for glaucoma). Severity of rubbing: 3 severe, 10 moderate, and 17 mild; frequency of daily rubbing: more than 10 times in 6, between 5 and 10 in 1, and <5 times in 23; rubbing was throughout the year in 13, seasonal in 6, and occasional in 11. Years of rubbing: 10 reported >20 years, 8 had between 11 and 20, 8 had between 6 and 10, and 4 had <6 years. For the 61 control patients who completed the survey, 14 admitted rubbing and 47 denied rubbing. Five control patients were witnessed ocular rubbing in the clinic (all before any potential therapy for glaucoma). Severity of rubbing: 1 severe, 2 moderate, and 11 mild; frequency of daily rubbing: more than 10 times in 1 and <5 times in 13; rubbing was throughout the year in 4, seasonal in 4, and occasional in 6. Years of rubbing: 4 had >20 years, 1 had between 11 and 20, 4 had between 6 and 10, and 5 had <6 years.
Literature review of positive risk factors for XFS in general [Tables 5-7][14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81] and XFS in young subjects [Table 8][82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99] was tabulated and this information was used to synthesize the literature findings with the current study findings.
Table 5.
Literature review of articles showing positive ocular risk factors in pseudoexfoliation
| First author (year of publication) | City, country | Sample size | Type of study | Risk factor | P value or hazard ratio |
|---|---|---|---|---|---|
| Akdemir (2016) | Istanbul, Turkey | 50 XFS, 20 XFS with glaucoma, 65 controls | Clinic-based cross-sectional study | Dry eye | <0.001 |
| Kozobolis (2004) | Crete, Greece | 40 XFS and 40 controls | Prospective, cross-sectional study | Dry eye | 0.01 |
| Kozobolis (1999) | Crete, Greece | 57 XFS versus 60 controls | Cross-sectional study | Dry eye | <0.002 |
| Öncel (2012) | Istanbul, Turkey | 31 XFS and 31 controls | Clinic-based case-control study | Dry eye | 0.001 |
| Rao (2018) | Odisha, India | 55 XFS with 40 controls | Clinic-based case-control study | Dry eye | <0.001 |
| Škegro (2015) | Zagreb, Croatia | 40 XFS and 40 controls | Clinic-based case-control study | Dry eye | <0.01 |
| Noori (2019) | Pune, India (Asian Indian) | 100 XFS and 100 controls | Clinic-based comparative study | Dry eye | 0.003 |
| Kaliaperumal (2014) | Puducherry, India | 30 XFS and 15 controls | Clinic-based comparative study | Dry eye | <0.001 |
| Pujar (2019) | Karnataka, India | 30 XFS and 30 controls | Clinic-based comparative study | Dry eye | <0.001 |
| Potemkin (2016) | Saint Peterburg, Russia | 66 XFS and 64 controls | Clinic-based comparative study | Meibomian gland dysfunction | <0.05 |
| Landers (2012) | Central Australia | 1884 with 72 XFS | Clinic-based cross-sectional study | Climatic keratopathy | <0.001 |
| Resnikoff (1991) | Bamako, Mali, East Africa | 2446 | Countryside survey | Climatic keratopathy | 6.4 (1.2-33.1) (P=0.02) |
| Forsisus (2002) | Peru (7 XFS), Novosibirsk (41 XFS in Russia), Åland (41 XFS in Finland) | International Biological Programme for study populations living in extreme climates | Samples of extreme climate International Biologic Programme | Climatic keratopathy | <0.05 |
| Yazgan (2015) | Zonguldak, Turkey | 45 healthy, 43 XFS and 30 XFS Glaucoma eyes | Clinic-based cross-sectional study | Decreased Corneal Hysteresis | <0.001 |
| Romero-Aroca (2011) | Taragona, Spain | 2342 with 309 XFS | Population-based cross-sectional study | Increased corneal endothelial polymorphism, polymegathism, cell loss | <0.001 |
| Yenerei (2011) | Istanbul, Turkey | 52 XFS and 42 controls | Clinic-based cross-sectional study | Decreased Corneal hysteresis and Corneal Resistance Factor | <0.05 |
| Palko (2017) | World literature | Literature before September 2016 | Meta-analysis | Decreased corneal nerves | 4 studies had P<0.05 |
| Palko (2017) | World literature | Literature prior to September 2016 | Meta-analysis | Decreased corneal endothelial cell count | 9 of 11 studies had P<0.05 |
| Topouzis 2019 | Thessaloniki, Northern Greece | 1468 with 19.6% XFS | Longitudinal, population-based study | More hyperopia | 0.72 per mm (0.57-0.92) |
| McCarty 2000 | Victoria, Australia | 3271 with 0.98% XFS | Cluster, stratified sampling | Glaucoma | 3.80 (1.73-8.33) |
| Sorkou 2020 | Greece | 42 XFS versus 72 controls | Cross-sectional clinic based | Glaucoma | 0.002 |
| Hietanen 1992 | Helsinki, Finland | 305 consecutive patients (77 XFS) scheduled for cataract surgery | Cross-sectional clinic based | Glaucoma | <0.001 (33.8% of XFS vs. 10.8% in non XFS) |
| Rotchford 2003 | South Africa | 1840 with 7.7% XFS | Cluster-based random cross-sectional sampling | Glaucoma | 2.5 (1.4-4.5) |
| Mitchell 1999 | Sydney, Australia | 3654 (Blue Mountains Eye Study) | Cross-sectional study | Glaucoma | 5.0 (2.6-9.6) |
| Forsman 2007 | Kökar island in southern Finland | 595 | Population-based eye examination | Glaucoma | 11.9 (6.2-22.9) |
| Bikbov (2020) | Ufa, Bashkortostan, Russia | 5899 | Population-based cross-sectional study | Glaucoma | 2.40 (1.36-4.23) (P=0.003) |
XFS: Pseudoexfoliation
Table 7.
Literature review of articles showing positive systemic vascular risk factors in pseudoexfoliation
| First author (year of publication) | Country (race if available) | Sample size | Type of study | Risk factor | P-value or hazard ratio (95% CI) |
|---|---|---|---|---|---|
| Vardhan (2017) | Tamil Nadu, India | 930 XFS and 476 controls | Cross-sectional clinic-based study | Systolic hypertension | 0.001 |
| Alpastan (2012) | Konya, Turkey | 31 XFS and 29 controls | Case-controlled observational study | Increased aortic stiffening | 0.021 |
| Yüksel (2006) | Kocaeli, Turkey | 25 XFS, 24 XFS glaucoma and 25 controls | Clinic-based comparative study | Decreased middle cerebral artery velocity | 0.005 |
| Yüksel (2006) | Kocaeli, Turkey | 16 XFS, 21 XFS glaucoma and 18 controls | Clinic-based case-control study | Ischemic brain damage | <0.05 |
| Kocabeyoglu 2013 | Ankara, Turkey | 40 XFS and 40 controls | Clinic-based prospective comparative study | Cerebrovascular disease | 0.026 |
| Kan (2017) | Samsun, Turkey | 50 cerebrovascular disease and 50 controls | Cross-sectional case-control study | Ischemic cerebrovascular disease | 0.02 |
| Chung (2018) | worldwide | 1308 XFS in 11 studies | Meta-analysis before 2017 | Cerebrovascular disease | 1.76 (1.40-2.22) |
| Chung (2018) | worldwide | 9583 XFS in 20 studies | Meta-analysis before 2017 | Cardiovascular disease | 1.61 (1.37-1.90) |
| Rumelaitienė (2020) | Kaunas, Lithuania | 1033 followed 10 years with XFS prevalence increasing from 10.3% to 34.2% | Longitudinal population-based study | Ischemic heart disease | 1.5 (P=0.014) |
| Djordjevic-Jocic (2012) | Nis, Serbia | 60 XFS, 60 XFS glaucoma, 60 open-angle glaucoma and 60 with cataract | Clinic-based 4-group comparison | Infrarenal AAA | <0.05 |
| Sarenac-Vulovic (2014) | Kragujevac, Serbia | 20 XFS, 20 XFS glaucoma, 20 controls | Clinic-based cross-sectional study | Abdominal aneurysm | 10% versus 0% P=0.018 |
| Wang 2014 | Meta-analysis | 16 studies 8533 XFS and 135,720 controls | Meta-analysis before 2014 | Vascular disease | 1.72 (1.31-2.26) for any vascular disease, 1.61 (1.22-2.14) for coronary heart disease, 1.59 (1.12-2.23) for cerebrovascular disease, and 2.48 (1.30-4.72) for aortic aneurysm |
AAA: Abdominal aortic aneurysm, XFS: Pseudoexfoliation, CI: Confidence interval, OR: Odds ratio
Table 8.
Systematic literature review of patients with early onset pseudoexfoliation pseudoexfoliation (<age 45 years)
| Author publication date | Age at diagnosis of XFS (years) | Primary ocular disease | Surgery | Trauma | Remarks and Country |
|---|---|---|---|---|---|
| Keratoconus (or allergic conjunctivitis) | 9 patients | ||||
| Yüksel (2005) | Developmental cataract | Extracapsular cataract extraction with sulcus posterior chamber implant age 6 | No | Corneal topography revealed a central steepening resembling keratoconus Turkey |
|
| Konstas (1997) | 13 | Congenital glaucoma | Trabeculectomy in infancy | No | Allergic conjunctivitis and lid dermatitis Greece |
| Küchle (1992) | 42 | Keratoconus | Penetrating keratoplasty both eyes with XFS appearing 4-5 years later in both eyes | No | Germany |
| Küchle (1992) | 37 | Keratoconus | Penetrating keratoplasty at 31 years | No | Germany |
| Hørven (1967) | 35 | Keratoconus | Penetrating keratoplasty age 24 | No | USA |
| Konstas (1992) | 42 | Keratoconus age 19 | Penetrating keratoplasty age 29 with long radial iridotomy | No | Only right eye had XFS Greece |
| Sampaolesi (1997) | 3 patients: 21 and 2 other young cases | Keratoconus | Penetrating keratoplasty | Not mentioned | Argentina |
| Ocular surgery | 9 patients 2 with penetrating trauma and 7 with glaucoma | ||||
| Sugar (1976) | 26 | Penetrating trauma | Repair of laceration age 11 months | Penetrating trauma | USA |
| Fakhraie (2012) | 30 | Traumatic glaucoma and cataract | Repair of limbal-scleral laceration | Limbal-scleral laceration age 4 years | Iran |
| Hørven (1967) | 31 | Juvenile glaucoma | Iridencleisis age 16 | No | USA |
| Fakhraie (2012) | 13 | Congenital glaucoma | Goniotomy age 6 months then trabeculectomy age 2 years both eyes | No | Only right eye had XFS Iran |
| Amini (2012) | 43 | Juvenile glaucoma | Argon laser trabeculoplasty age 28; then posterior lip sclerotomy; then trabeculectomy | No | Only left eye had XFS Iran |
| Amini (2012) | 40 | Juvenile glaucoma | Trabeculectomy age 27 then Ahmed valve | No | 2 episodes of blebitis; Only left eye had XFS Iran |
| Amini (2012) | 40 | Juvenile glaucoma | Argon laser trabeculoplasty age 36 then trabeculectomy age 37 | No | Only left eye had XFS Iran |
| Amini (2012) | 18 | Congenital glaucoma | Trabeculotomy age 1 year; then trabeculectomy twice; then Ahmed valve | No | Only left eye had XFS Iran |
| Kumar (2019) | 28 | Developmental glaucoma | Trabeculectomy age 2 | No | India |
| Survey or case report | 17 patients | ||||
| Hørven (1967) | 31 | NM | NM | NM | USA |
| Hørven (1967) | 35 | NM | NM | NM | USA |
| Bartholomew (1971) | 7 XFS <40 years | NM | NM | NM | Bantu tribe South Africa |
| Tarkkanen (1962) | 31 | NM | NM | NM | Finland |
| Taylor (1977) | 35 | NM | NM | NM | Australia |
| Summanen (1988) | 38 | NM | NM | NM | Saudi Arabia |
| Khanzada (1985) | 32 | NM | NM | NM | Pakistan |
| Joannides (1961) | 39 | NM | NM | NM | Greece |
| Als (1980) | 2 XFS <40 years | NM | NM | NM | Iceland |
| Oliveira (2006) | 42 | NM | NM | NM | USA |
NM: Not mentioned, XFS: Pseudoexfoliation
Discussion
In the Lebanese cohort under investigation, XFS was associated with advanced age, glaucoma, habitual ocular rubbing, and longer time for cataract surgery. While advanced age [Table 6],[39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70] glaucoma [Table 5],[14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38] and longer surgery duration[100] are well established risk factors for XFS [Table 5],[14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36,37,38] ocular rubbing has received little attention in the literature.
Table 6.
Literature review of articles showing positive systemic nonvascular risk factors in pseudoexfoliation
| First author (year of publication) | Country | Sample size | Type of study | Risk factor | P value or OR (95% CI) |
|---|---|---|---|---|---|
| Kim 2016 | South Korea | 13,223 | Korean National Health and Nutrition Examination Survey | Increasing age | 1.04 (0.99-1.09) P=0.016 |
| Krishnadas 2003 | Southern India | 5150 | Population-based cross-sectional study | Increasing age | <0.001 |
| Rotchford 2003 | South Africa | 1840 with 7.7% XFS | Cluster-based random cross-sectional sampling | Increasing age | <0.001 |
| Jonas 2013 | Central India | 4711 with 69 XFS | Population-based, cross-sectional study | Increasing age | 1.11 (1.09-1.13) P<0.001 |
| Arnarsson (2010) | Reykjavik, Iceland | 1045 | Reykjavik eye study population-based study | Increasing age | 0.001 |
| Pavičić-Astaloš (2016) | Zagreb, Croatia | 5349 with 188 XFS | Clinic-based cross sectional study | Increasing age | <0.001 |
| Bikbov (2020) | Ufa, Bashkortostan, Russia | 5899 | Population-based cross-sectional study | Increasing age | 1.09 (1.07-1.11) P<0.001 |
| You (2013) | Beijing, China | 3468 (Beijing Eye Study) | Population-based cross-sectional cohort study | Increasing age | 1.08 (1.04-1.10) P<0.001 |
| Hepsen (2007) | Ankara, Turkey | 72 XFS and 65 control with cataract | Clinic-based cross-sectional study | Increasing age | <0.001 |
| Berhanu (2020) | Baso and Worena District, Central Ethiopia | 682 | Population-based cross-sectional study | Increasing Age | 0.038 |
| Hiller 1982 | Massachusetts, USA | 2675 | Population-based survey (Framingham Eye Study) | Female gender predominance | 2.3:1 female: male (significant) |
| Ekström 2019 | Tierp, Sweden | 1065 with 78 XFS | Population survey | Female gender predominance | 1.59 (1.16-2.18) |
| Topouzis 2019 | Thessaloniki, Northern Greece | 1468 with 19.6% XFS | Longitudinal, population-based study | Female gender predominance | 0.02 |
| Arnarsson (2007) | Reykjavik, Iceland | 1045 with 108 XFS | Reykjavik Eye Study population based study | Female gender predominance | <0.001 |
| Krishnadas 2003 | Southern India | 5150 | Population-based cross-sectional study | Male gender predominance | 0.01 |
| Yalaz (1992) | Adana, Turkey | 1356 | Clinic-based cross-sectional study | Male gender predominance | <0.001 |
| Jonas 2013 | Central India | 4711 with 69 XFS | Population-based, cross-sectional study | Lower body mass index | 0.88 (0.82-0.95) P=0.001 |
| Arnarsson (2010) | Reykjavik, Iceland | 1045 | Reykjavik Eye Study population based study | Fruit intake | 0.20 (0.04-0.91) P=0.04 |
| Pasquale 2012 | USA | 78,977 women from nurses’ health study and 41,202 men from health professionals follow-up study with 360 XFS | Longitudinal population-based study | Caffeine intake | ≥3 cuPs coffee daily increased risk of XFS glaucoma 1.66 (1.09-2.54) P=0.02 |
| Kang 2014 | USA | 78,977 women from nurses’ health study and 41,202 men from health professionals follow-up study with 360 XFS | Longitudinal population-based study | Folate intake | XFS glaucoma associated with highest quintile (Q5; ≥ 654 µg/day) 0.75 (0.54-1.04) P=0.02 |
| Tijani 2017 | Rabat, Morocco | 260 scheduled for cataract surgery | Retrospective clinic-based | Smoking | 5.2 (1.35-20.15) P=0.01 |
| Pasquale 2014 | USA and Israel | 118 XFS and 106 controls; Israel 67 XFS and 72 controls | Clinic-based, case-control studies | Higher latitude | Each degree of latitude away from equator associated with 11% increased odds of XFS 1.11 (1.05-1.17); P<0.001 |
| Pasquale 2014 | USA and Israel | United States: 118 XFS and 106 controls; Israel: 67 XFS and 72 controls | Clinic-based, case-control studies | Solar exposure | Every hour weekly sPent outdoors during summer, over lifetime 1.04 (1.00-1.07) P=0.03 |
| Arakaki 2020 | Kumejima, Okinawa, Japan | 3762 | Population-based survey ≥40 years | Working outdoor | 2.18 (0.99-4.82) P=0.04 |
| Wirostko 2016 | Utah, USA | 132,772 women in Utah Medicare | Cross-sectional analysis | Pelvic Organ Prolapse | 1.56 (1.42-1.72) |
| Besch 2018 | Utah, USA | Hospital charts compared with population controls | Chart review University of Utah Healthcare medical records | Indirect Inguinal Hernia | 2.3 (1.4-3.5) (P=0.03) |
| Sorkhabi (2012) | Tabriz, Iran | 30 XFS and 30 controls | Clinic-based prospective comparative study | Markers of inflammation and peripheral endothelial dysfunction | 0.002 |
| Dursun (2015) | Sivas, Turkey | 26 XFS, 26 XFS with glaucoma, 26 controls with cataract | Clinic-based prospective comparative study | Increased oxidative stress | <0.05 |
| Yazdani (2008) | Tehran, Iran (Caucasian race) | 83 subjects with XFS and 83 controls | Prospective clinic-based case-control study | Sensorineural hearing loss | 6.69 (3.49-11.79) P<0.001 |
| Papadopoulos (2012) | Patras, Greece (Caucasian race) | 94 XFS and 44 controls | Prospective clinic-based case-control | Sensorineural hearing loss | 0.007 |
| Sarenac-Vulovic (2014) | Kragujevac, Serbia | 20 XFS, 20 XFS with glaucoma, 20 controls | Clinic-based cross-sectional study | Sensorineural hearing loss | 6.5 (P=0.03) |
| Singham (2014) | Kuala Lumpur, Malaysia | 68 XFS and 55 controls | Prospective clinic-based case-control study | Sensorineural hearing loss | 3.00 (1.25-7.19) P=0.01 |
| Cumurcu (2013) | Turgut, Turkey (Caucasian race) | 67 XFS and 67 controls | Clinic-based cross-sectional study | Alzheimer neurodegenerative impediment | P<0.001 |
| Linnér (2001) | Goteborg, Sweden | 11 of 39 Alzheimer had XFS (clinic) versus 23 of 476 (population survey) had XFS | Clinic-based versus population survey | Alzheimer neurodegenerative impairment | 5.84 (2.87-11.98) |
| Turgut Coba (2018) | Antalya, Turkey | 31 XFS and 31 controls | Case-control study | Peripheral Neurosensory impairment | <0.05 |
| Arnarsson (2010) | Reykjavik, Iceland | 1045 | Reykjavik Eye Study population-based study | Asthma | 1.91 (1.00-3.62) |
| Batur (2018) | Van, Turkey | 60 XFS and 52 controls | Clinic-based comparative study | Decreased pulmonary function tests | 0.036 |
| Yaşar (2019) | Eskişehir, Turkey | 2009 with 100 XFS | Population-based, cross-sectional study | Depressive disorder | 0.024 |
| Cumurcu (2006) | Tokat, Turkey | 41 XFS glaucoma, 32 POAG and 40 controls | Clinic-based comparative study | Depressive disorder | 007 |
| Scharfenberg (2019) | Leipzig, Germany (Caucasian) | Patients with ophthalmological operations | Hospital-based retrospective case-control study | Benign prostatic hypertrophy | 2.3 (1.4-3.7) |
| Gökce (2015) | Ankara, Turkey | 34 XFS and 58 controls | Clinic-based comparative study | Erectile dysfunction | 0.002 |
XFS: Pseudoexfoliation, CI: Confidence interval, OR: Odds ratio, POAG: Primary open-angle glaucoma
What are the causes of ocular rubbing in exfoliation syndrome?
A major precipitating factor in the cohort under investigation is the presence of dry eye and to a lesser extent the presence of allergic conjunctivitis. Rubbing was associated in the current study with dry eye, and dry eye is a known feature in XFS patients.[101] XFS patients have lower basal tear test scores, decreased tear breakup time, loss of goblet cell density (by impression conjunctival cytology),[101] and significant Meibomian gland dysfunction.[23] These ocular surface disorders have been attributed partly to deposition of exfoliation material in the conjunctiva.[102,103] Possible other explanations have included: degenerative disease of the ocular surface with deposition of neurodegenerative proteins similar to that found in Alzheimer's or Parkinson, autoinflammatory disease of the conjunctiva, and vascular insufficiency [Table 9]. Allergic conjunctivitis was also associated with rubbing but to a lesser extent in the present Lebanese study with one subject having XFS and vernal catarrh. Asthma and abnormal pulmonary function tests (obstructive airway disease) have been associated with XFS [Table 6].[39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70] Batur et al.[66] in 60 patients with XFS without pulmonary disease detected a significant decline in pulmonary function tests versus 52 controls matched for age, gender, and smoking history. Similarly, in the Reykjavik Eye Study, a population-based study involving 1045 subjects (108 XFS) followed for 5 years, asthma was significantly associated with XFS (odds ratio 1.91; [95% confidence interval 1.00–3.62]) by multivariate analysis.
Table 9.
Possible causes of ocular rubbing, dry eye and allergic conjunctivitis in pseudoexfoliation subjects
| 1. Decreased basal tear secretion[14,15,16,17,18,19,20,21,22] |
| 2. Loss of goblet cells[101] |
| 3. Meibomian gland dysfunction[23] |
| 4. Deposition of XFS material in conjunctiva[102,103] |
| 5. Degenerative changes in conjunctiva similar to changes in Alzheimer (Presinilin) or Parkinson (alpha synuclein)[7,63,64] |
| 6. Auto inflammatory disease of ocular surface[57,58,104,105] |
| 7. Vaso-occlusive disorder (loss of limbal vascular pattern)[106] |
| 8. Asthma association with XFS[42,66] |
| 9. Keratoconus associated with young patients having XFS[82,87] |
XFS: Pseudoexfoliation
What are the consequences of ocular rubbing on the eye?
Acute rubbing of the eye can cause transient astigmatism,[107,108] elevated intraocular pressure,[109,110] and corneal hydrops.[111] Chronic rubbing has been linked with the development of keratoconus,[112,113] cataract,[114] optic disc cupping,[115] and retinal detachment.[116] Küchle[84] reported 2 young subjects with keratoconus necessitating penetrating keratoplasty at ages 31, 37 and 40 years with XFS detected between 4 and 6 years after surgery. Küchle attributed this temporal relationship to possible slow virus transmitted from the donor cornea. We propose that rubbing caused the concomitant keratoconus and XFS. This is further confirmed by analysis of XFS in young subjects [Table 8]:[82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99] Half of young subjects with a reported risk for XFS had keratoconus. Out of 35 subjects with XFS under 45 years of age, detailed clinical data were available in 18:9 having some kind of corneal ectasia and 9 having had intraocular surgeries (2 after penetrating trauma and 7 had primary glaucoma). The decreased endothelial cell count in XFS[28] could be due to XFS material accumulation[30] or from eye rubbing as rubbing per say decreases endothelial cell density.[117,118]
Zonular stretching in health, trauma, and exfoliation syndrome
The function of the zonules is mechanical with its relatively elastic fibers able to stretch up to four times their original length before breaking, but this elasticity declines markedly with age. Biochemically, a zonule consists of a microfibril backbone comprised fibrillin and a restricted set of glycoproteins (80% being FBN1 and LTBP2).[119] LOXL1, a crosslinking enzyme responsible collagen and elastin biogenesis, is detected at significant levels, and this enzyme is implicated in the pathogenesis of XFS. Assia et al.[120] tested the stretching capability of lens zonules in 40 postmortem human eyes. They found that zonules can slowly stretch up to 3.82 mm in young subjects before rupturing. That value of maximal zonular stretch tended to decrease with the age by 0.5 mm for every 5 years in normal eyes, while eyes with XFS had even more friable zonules. Similarly, Saber et al.[121] found a median mechanical zonular stretch tolerance of 3.00 mm on postmortem eyes that previously had extracapsular extraction. The zonular apparatus is involved extensively in XFS. Ultrasound biomicroscopic grading of zonular changes in XFS included uneven and disrupted zonules, followed by patchy deposits on the zonules. A more severe grade involves diffuse granulation over thickened zonules[122] with web-like structure in between zonules. The end stage is extensive loss of zonules.[123] Similarly, occult zonular defects were present on ultrasound biomicroscopy in 21 of 49 patients (42.9%) following ocular trauma.[124] XFS was detected in a study of young amateur boxers.[125] How much the eye is indented around the limbus during ocular rubbing or ocular trauma? In acute blunt trauma, the damage is one time and severe, while with severe repetitive rubbing, the damage is cumulative progressive and infinitesimal. The eyeball is deformed with shortening of anteroposterior length and distension of the equatorial region, leading to stretch of the zonules [Figure 1a and b]. Delori et al.[126] demonstrated in a pig eye model that blunt trauma causes indentation of the cornea with lens–cornea touch and backward displacement of the lens together with widening of the pars plana. This causes severe zonular stretching over several milliseconds [Figure 1b]. Second, there is compression of the angle, iris, ciliary body, anterior vitreous, lens over the area rubbed, resulting in squeezing injury to the zonules [Figure 2a and b]. Third, XFS material can act as cutting fulcrum when eye is rubbed or traumatized. Note that flaccid cornea, or eyes with hypotony, or have more distortion of cornea and more indentation of the globe.
Figure 1.

Sketch of a cross-section of the anterior globe centered around the zonules. (a) Normal section. (b) Section during rubbing. With vigorous knuckle rubbing or blunt trauma to the central cornea, the cornea indents with retraction of the lens and stretching of the ciliary body causing sudden elongation of the zonules
Figure 2.

(a) Small section through limbus. (b) Section of limbus after ocular rubbing on the limbal area. If rubbing center on the limbus or pars plana, there is contusion of the zonules by a smashing effect
Delori et al.[126] used the technology of high-speed cinematography and single-flash high-speed photographs to document the globe deformation in 75 pig eyes immersed in gelatin, with high impact pellet to the center of the cornea. The distance between the posterior pole of the lens to the vitreous base elongated by 28% at 0.4 ms and shrank by 13% (from baseline) at 1 ms before resuming baseline level. If we extrapolate similar changes in humans, this deformation translates to sudden distension of the zonules by around 3 mm. The same applies after vigorous rubbing, but the distension of the zonules is slower and milder as witnessed by rubbing videos by volunteer on dynamic medical imaging (Investigating Eye Rubbing with Dynamic Medical Imaging, www.defeatkeratoconus.com). The equator of the vitreous base measures around 21 mm in normal eyes and expands by 28% or near 3.0 mm on either side of the zonules over a fraction of a millisecond in pellet or rub model. Superfast distension of the zonules leads to more breakage than gradual distension; hence, the breakage distension at high speed is estimated to be around 1 mm or so.[127]
Itching from atopy or dry eye is a trigger for chronic aggressive rubbing. Other causes of ocular rubbing include several disorders associated with an obsessive- compulsive form of ocular rubbing: Tourette syndrome,[128] Leber's congenital amaurosis, retinitis pigmentosa,[129] and the extreme form of the oculo-digital reflex also known as the pop-eye phenomenon.[130] To control chronic rubbing that may be the cause of XFS, there is a need for an increased vigilance and care of the eyes in XFS patients in the form of: education, meticulous therapy of ocular surface disease (preservative free antiallergic and lubricant, therapy of meibomian gland dysfunction or blepharitis), wearing of safety glasses, psychologic consultation or need for/pharmacotherapy. Larger studies are needed to delineate the subset of XFS that relate to environmental factors.
Based on the above data [Tables 2-9], we propose that ocular rubbing [Figure 3] leads in susceptible eyes to keratoconus, iridoschisis, disruption of zonules, and partial tears of anterior capsule around zonules.[113,131,132,133] Following severe rubbing, the intraocular pressure can rise to 100 mmHg[109] with collapse of peripheral anterior chamber, with the zonules becoming stretched or compressed by the posterior part of the iris, leading to tearing.
Figure 3.

Proposed pathophysiology of associated ocular, systemic, and biochemical factors in relation to exfoliation syndrome
The current study suffers from the shortcoming of any survey and from the small number of participants. However, the strength of the study includes near absence of nonresponse (high nonresponse rate can result in bias of the measures of outcome) and combining the current data with data from the systematic literature review, leading to a proposed comprehensive pathophysiology of XFS. Scientific evidence has shown that XFS is a multifactorial disease involving complex interaction of possible genetic and environmental factors. Our study and review of the literature point to a new factor (ocular rubbing) implicated in the pathogenesis of XFS and hence the need to better manage concurrent ocular surface disorder in these patients. Further studies with larger numbers of patients are needed to delineate more clearly the contribution of ocular rubbing, ocular surface disease, and other ocular or systemic or genetic factors [Tables 5-8] to the development of XFS.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References
- 1.Nazarali S, Damji F, Damji KF. What have we learned about exfoliation syndrome since its discovery by John Lindberg 100 years ago? Br J Ophthalmol. 2018;102:1342–50. doi: 10.1136/bjophthalmol-2017-311321. [DOI] [PubMed] [Google Scholar]
- 2.Ritch R, Schlötzer-Schrehardt U. Exfoliation syndrome. Surv Ophthalmol. 2001;45:265–315. doi: 10.1016/s0039-6257(00)00196-x. [DOI] [PubMed] [Google Scholar]
- 3.Madden JG, Crowley MJ. Factors in the exfoliation syndrome. Br J Ophthalmol. 1982;66:432–7. doi: 10.1136/bjo.66.7.432. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ritch R. Systemic associations of pseudoexfoliatiion. Asia Pac J Ophthalmol. 2016;5:45–50. doi: 10.1097/APO.0000000000000187. [DOI] [PubMed] [Google Scholar]
- 5.John SW, Harder JM, Fingert JH, Anderson MG. Animal models of exfoliation syndrome, now and future. J Glaucoma. 2014;23:S68–72. doi: 10.1097/IJG.0000000000000121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Yuan Y, Schlötzer-Schrehardt U, Ritch R, Call M, Chu FB, Dong F, et al. Transient expression of Wnt5a elicits ocular features of pseudoexfoliation syndrome in mice. PLoS One. 2019;14:e0212569. doi: 10.1371/journal.pone.0212569. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Bernstein AM, Ritch R, Wolosin JM. Exfoliation syndrome: A disease of autophagy and LOXL1 proteopathy. J Glaucoma. 2018;27 Suppl 1:S44–53. doi: 10.1097/IJG.0000000000000919. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Ghaffari Sharaf M, Damji KF, Unsworth LD. Recent advances in risk factors associated with ocular exfoliation syndrome. Acta Ophthalmol. 2020;98:113–20. doi: 10.1111/aos.14298. [DOI] [PubMed] [Google Scholar]
- 9.Kang JH, Wiggs JL, Pasquale LR. Relation between time spent outdoors and exfoliation glaucoma or exfoliation glaucoma suspect. Am J Ophthalmol. 2014;158:605–14. doi: 10.1016/j.ajo.2014.05.015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Jiwani AZ, Pasquale LR. Exfoliation syndrome and solar exposure: New epidemiological insights into the pathophysiology of the disease. Int Ophthalmol Clin. 2015;55:13–22. doi: 10.1097/IIO.0000000000000092. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Miglior S, Bertuzzi F. Exfoliative glaucoma: New evidence in the pathogenesis and treatment. Prog Brain Res. 2015;221:233–41. doi: 10.1016/bs.pbr.2015.06.007. [DOI] [PubMed] [Google Scholar]
- 12.Detorakis ET, Kozobolis VP, Pallikaris IG, Spandidos DA. Detection of herpes simplex virus in pseudoexfoliation syndrome and exfoliation glaucoma. Acta Ophthalmol Scand. 2002;80:612–6. doi: 10.1034/j.1600-0420.2002.800610.x. [DOI] [PubMed] [Google Scholar]
- 13.Teekhasaenee C, Suwan Y, Supakontanasan W, Tulvatana W, Ritch R. The clinical spectrum and a new theory of pathogenesis of true exfoliation syndrome. Ophthalmology. 2016;123:2328–37. doi: 10.1016/j.ophtha.2016.07.030. [DOI] [PubMed] [Google Scholar]
- 14.Akdemir MO, Kirgiz A, Ayar O, Kaldirim H, Mert M, Cabuk KS, et al. The effect of pseudoexfoliation and pseudoexfoliation induced dry eye on central corneal thickness. Curr Eye Res. 2016;41:305–10. doi: 10.3109/02713683.2015.1030505. [DOI] [PubMed] [Google Scholar]
- 15.Kozobolis VP, Christodoulakis EV, Naoumidi II, Siganos CS, Detorakis ET, Pallikaris LG. Study of conjunctival goblet cell morphology and tear film stability in pseudoexfoliation syndrome. Graefes Arch Clin Exp Ophthalmol. 2004;242:478–83. doi: 10.1007/s00417-004-0865-3. [DOI] [PubMed] [Google Scholar]
- 16.Kozobolis VP, Detorakis ET, Tsopakis GM, Pallikaris IG. Evaluation of tear secretion and tear film stability in pseudoexfoliation syndrome. Acta Ophthalmol Scand. 1999;77:406–9. doi: 10.1034/j.1600-0420.1999.770409.x. [DOI] [PubMed] [Google Scholar]
- 17.Öncel BA, Pinarci E, Akova YA. Tear osmolarity in unilateral pseudoexfoliation syndrome. Clin Exp Optom. 2012;95:506–9. doi: 10.1111/j.1444-0938.2011.00683.x. [DOI] [PubMed] [Google Scholar]
- 18.Rao A, Das G, Sarangi S, Padhy D. Conjunctival changes in different clinical variants of early pseudoexfoliation. Int Ophthalmol. 2018;38:2477–85. doi: 10.1007/s10792-017-0758-1. [DOI] [PubMed] [Google Scholar]
- 19.Škegro I, Suić SP, Kordić R, Jandroković S, Petriček I, Kuzman T, et al. Ocular surface disease in pseudoexfoliation syndrome. Coll Antropol. 2015;39:43–5. [PubMed] [Google Scholar]
- 20.Noori S, Sati A, Moulick PS, Jaya K, Sandeep S, Rupali B, et al. Tear film abnormalities in pseudoexfoliation syndrome and normal healthy participants: A comparative analysis. Med J Armed Forces India. 2020;76:303–6. doi: 10.1016/j.mjafi.2019.01.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Kaliaperumal S, Govindaraj I, Rao V. Abnormalities of tear function in patients with pseudoexfoliation. Int J Clin Exp Physiol. 2014;1:34. [Google Scholar]
- 22.Pujar C, Hiremath S, Gadag VR. Correlations between tear function abnormalities and pseudoexfoliation: A comparative study. Indian J Clin Exp Ophthalmol. 2019;5:118–20. [Google Scholar]
- 23.Potemkin VV, Ageeva EV. Pseudoexfoliation and meibomian gland dysfunction. Ophthalmol J. 2016;9:52–7. [Google Scholar]
- 24.Landers J, Henderson T, Craig J. Prevalence of pseudoexfoliation syndrome in indigenous Australians within central Australia: The Central Australian Ocular Health Study. Clin Exp Ophthalmol. 2012;40:454–7. doi: 10.1111/j.1442-9071.2011.02696.x. [DOI] [PubMed] [Google Scholar]
- 25.Resnikoff S, Filliard G, Dell'Aquila B. Climatic droplet keratopathy, exfoliation syndrome, and cataract. Br J Ophthalmol. 1991;75:734–6. doi: 10.1136/bjo.75.12.734. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Forsius H, Forsman E, Fellman J, Eriksson AW. Exfoliation syndrome: Frequency, gender distribution and association with climatically induced alterations of the cornea and conjunctiva. Acta Ophthalmol Scand. 2002;80:478–84. doi: 10.1034/j.1600-0420.2002.800504.x. [DOI] [PubMed] [Google Scholar]
- 27.Yazgan S, Celik U, Alagöz N, Taş M. Corneal biomechanical comparison of pseudoexfoliation syndrome, pseudoexfoliative glaucoma and healthy subjects. Curr Eye Res. 2015;40:470–5. doi: 10.3109/02713683.2014.930157. [DOI] [PubMed] [Google Scholar]
- 28.Romero-Aroca P, Masip-Serra R, Martínez-Salcedo I, Salvat-Serra M, Fernández-Ballart J, Bautista-Peérez Á. High prevalence of pseudoexfoliation syndrome and its complications in Tarragona in northeast Spain. Eur J Ophthalmol. 2011;21:580–8. doi: 10.5301/EJO.2011.6254. [DOI] [PubMed] [Google Scholar]
- 29.Yenerel NM, Gorgun E, Kucumen RB, Oral D, Dinc UA, Ciftci F. Corneal biomechanical properties of patients with pseudoexfoliation syndrome. Cornea. 2011;30:983–6. doi: 10.1097/ICO.0b013e318213a80d. [DOI] [PubMed] [Google Scholar]
- 30.Palko JR, Qi O, Sheybani A. Corneal alterations associated with pseudoexfoliation syndrome and glaucoma: A literature review. J Ophthalmic Vis Res. 2017;12:312–24. doi: 10.4103/jovr.jovr_28_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Topouzis F, Founti P, Yu F, Wilson MR, Coleman AL. Twelve-year incidence and baseline risk factors for pseudoexfoliation: The Thessaloniki eye study (an American Ophthalmological Society Thesis) Am J Ophthalmol. 2019;206:192–214. doi: 10.1016/j.ajo.2019.05.005. [DOI] [PubMed] [Google Scholar]
- 32.Mccarty CA, Taylor HR. Pseudoexfoliation syndrome in Australian adults. Am J Ophthalmol. 2000;129:629–33. doi: 10.1016/s0002-9394(99)00466-3. [DOI] [PubMed] [Google Scholar]
- 33.Sorkou KN, Tsinopoulos IT, Tsaousis KT, Karamitsos A, Meditskou S, Ziakas N, et al. Ease of hydrodissection during phacoemulsification: A comparison between patients with and those without exfoliation syndrome. Ophthalmic Res. 2020;63:497–500. doi: 10.1159/000507121. [DOI] [PubMed] [Google Scholar]
- 34.Hietanen J, Kivelä T, Vesti E, Tarkkanen A. Exfoliation syndrome in patients scheduled for cataract surgery. Acta Ophthalmol (Copenh) 1992;70:440–6. doi: 10.1111/j.1755-3768.1992.tb02112.x. [DOI] [PubMed] [Google Scholar]
- 35.Rotchford AP, Kirwan JF, Johnson GJ, Roux P. Exfoliation syndrome in black South Africans. Arch Ophthalmol. 2003;121:863–70. doi: 10.1001/archopht.121.6.863. [DOI] [PubMed] [Google Scholar]
- 36.Mitchell P, Wang JJ, Hourihan F. The relationship between glaucoma and pseudoexfoliation: The Blue Mountains Eye Study. Arch Ophthalmol. 1999;117:1319–24. doi: 10.1001/archopht.117.10.1319. [DOI] [PubMed] [Google Scholar]
- 37.Forsman E, Cantor RM, Lu A, Eriksson A, Fellman J, Järvelä I, et al. Exfoliation syndrome: Prevalence and inheritance in a subisolate of the Finnish population. Acta Ophthalmol Scand. 2007;85:500–7. doi: 10.1111/j.1600-0420.2007.00978.x. [DOI] [PubMed] [Google Scholar]
- 38.Bikbov MM, Zainullin RM, Gilmanshin TR, Kazakbaeva GM, Yakupova DF, Nuriev IF, et al. Prevalence and associated factors of pseudoexfoliation in a Russian population: The ural eye and medical study. Am J Ophthalmol. 2020;210:158–66. doi: 10.1016/j.ajo.2019.10.003. [DOI] [PubMed] [Google Scholar]
- 39.Kim S, Lim SH, Sung KR, Yun SC, Kim CY, Park KH, et al. Prevalence of pseudoexfoliation syndrome and associated factors in South Koreans: The Korean National Health and Nutrition Examination Survey. Ophthalmic Epidemiol. 2016;23:298–302. doi: 10.3109/09286586.2015.1131992. [DOI] [PubMed] [Google Scholar]
- 40.Krishnadas R, Nirmalan PK, Ramakrishnan R, Thulasiraj RD, Katz J, Tielsch JM, et al. Pseudoexfoliation in a rural population of southern India: The Aravind Comprehensive Eye Survey. Am J Ophthalmol. 2003;135:830–7. doi: 10.1016/s0002-9394(02)02271-7. [DOI] [PubMed] [Google Scholar]
- 41.Jonas JB, Nangia V, Matin A, Bhojwani K, Sinha A, Khare A, et al. Pseudoexfoliation: Normative data and associations. The Central India Eye and Medical Study. PLoS One. 2013;8:e76770. doi: 10.1371/journal.pone.0076770. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Arnarsson A, Jonasson F, Damji KF, Gottfredsdottir MS, Sverrisson T, Sasaki H. Exfoliation syndrome in the Reykjavik Eye Study: Risk factors for baseline prevalence and 5-year incidence. Br J Ophthalmol. 2010;94:831–5. doi: 10.1136/bjo.2009.157636. [DOI] [PubMed] [Google Scholar]
- 43.Pavičić-Astaloš J, Koluder A, Knežević L, Zorić Geber M, Novak-Lauš K, Csik T, et al. Prevalence of pseudoexfoliation syndrome and pseudoexfoliation glaucoma in population of North-West Croatia aged 40 and over. Acta Clin Croat. 2016;55:483–9. doi: 10.20471/acc.2016.55.03.19. [DOI] [PubMed] [Google Scholar]
- 44.You QS, Xu L, Wang YX, Yang H, Ma K, Li JJ, et al. Pseudoexfoliation: Normative data and associations: The Beijing eye study 2011. Ophthalmology. 2013;120:1551–8. doi: 10.1016/j.ophtha.2013.01.020. [DOI] [PubMed] [Google Scholar]
- 45.Hepsen IF, Yağci R, Keskin U. Corneal curvature and central corneal thickness in eyes with pseudoexfoliation syndrome. Can J Ophthalmol. 2007;42:677–80. doi: 10.3129/i07-145. [DOI] [PubMed] [Google Scholar]
- 46.Berhanu YA, Giorgis AT, Alemu AM. Prevalence of ocular pseudoexfoliation in Baso and Worena District, Central Ethiopia. Ethiop J Health Dev. 2020;34:54–8. [Google Scholar]
- 47.Hiller R, Sperduto RD, Krueger DE. Pseudoexfoliation, intraocular pressure, and senile lens changes in a population-based survey. Arch Ophthalmol. 1982;100:1080–2. doi: 10.1001/archopht.1982.01030040058007. [DOI] [PubMed] [Google Scholar]
- 48.Ekström C, Wilger S, Wanhainen A. Pseudoexfoliation and aortic aneurysm: A long-term follow-up study. Acta Ophthalmol. 2019;97:80–3. doi: 10.1111/aos.13882. [DOI] [PubMed] [Google Scholar]
- 49.Arnarsson A, Damji KF, Sverrisson T, Sasaki H, Jonasson F. Pseudoexfoliation in the Reykjavik Eye Study: Prevalence and related ophthalmological variables. Acta Ophthalmol Scand. 2007;85:822–7. doi: 10.1111/j.1600-0420.2007.01051.x. [DOI] [PubMed] [Google Scholar]
- 50.Yalaz M, Othman I, Nas K, Eroğlu A, Homurlu D, Cikintas Z, et al. The frequency of pseudoexfoliation syndrome in the eastern Mediterranean area of Turkey. Acta Ophthalmol (Copenh) 1992;70:209–13. doi: 10.1111/j.1755-3768.1992.tb04125.x. [DOI] [PubMed] [Google Scholar]
- 51.Pasquale LR, Wiggs JL, Willett WC, Kang JH. The Relationship between caffeine and coffee consumption and exfoliation glaucoma or glaucoma suspect: A prospective study in two cohorts. Invest Ophthalmol Vis Sci. 2012;53:6427–33. doi: 10.1167/iovs.12-10085. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Tijani M, Albaroudi N, Boutimzine N, Cherkawi O, Laghmari M. Prévalence du syndrome exfoliatif et profil cardiovasculaire des patients programmés pour chirurgie de cataracte. J Fr Ophtalmol. 2017;40:623–8. doi: 10.1016/j.jfo.2017.02.008. [DOI] [PubMed] [Google Scholar]
- 53.Pasquale LR, Jiwani AZ, Zehavi-Dorin T, Majd A, Rhee DJ, Chen T, et al. Solar exposure and residential geographic history in relation to exfoliation syndrome in the United States and Israel. JAMA Ophthalmol. 2014;132:1439–45. doi: 10.1001/jamaophthalmol.2014.3326. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Arakaki Y, Sawaguchi S, Iwase A, Tomidokoro A, Araie M. Pseudoexfoliation syndrome and relating factors in a rural Japanese population: The Kumejima Study. Acta Ophthalmol. 2020;98:e888–e894. doi: 10.1111/aos.14396. [DOI] [PubMed] [Google Scholar]
- 55.Wirostko BM, Curtin K, Ritch R, Thomas S, Allen-Brady K, Smith KR, et al. Risk for exfoliation syndrome in women with pelvic organ prolapse: A Utah Project on Exfoliation Syndrome (UPEXS) Study. JAMA Ophthalmol. 2016;134:1255–62. doi: 10.1001/jamaophthalmol.2016.3411. [DOI] [PubMed] [Google Scholar]
- 56.Besch BM, Curtin K, Ritch R, Allingham RR, Wirostko BM. Association of exfoliation syndrome with risk of indirect inguinal hernia: The Utah Project on Exfoliation Syndrome. JAMA Ophthalmol. 2018;136:1368–74. doi: 10.1001/jamaophthalmol.2018.4157. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Sorkhabi R, Ghorbanihaghjo A, Ahoor M, Nahaei M, Rashtchizadeh N. High-sensitivity C-reactive protein and tumor necrosis factor alpha in pseudoexfoliation syndrome. Oman Med J. 2013;28:16–9. doi: 10.5001/omj.2013.04. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Dursun F, Vural Ozec A, Aydin H, Topalkara A, Dursun A, Toker MI, et al. Total oxidative stress, paraoxonase and arylesterase levels at patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma. Int J Ophthalmol. 2015;8:985–90. doi: 10.3980/j.issn.2222-3959.2015.05.24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Yazdani S, Tousi A, Pakravan M, Faghihi AR. Sensorineural hearing loss in pseudoexfoliation syndrome. Ophthalmology. 2008;115:425–9. doi: 10.1016/j.ophtha.2007.10.038. [DOI] [PubMed] [Google Scholar]
- 60.Papadopoulos TA, Charalabopoulou M, Vathylakis I, Goumas P, Gartaganis S, Naxakis S. Prevalence and severity of sensorineural hearing loss in patients with exfoliation syndrome. Eur Rev Med Pharmacol Sci. 2012;16:902–7. [PubMed] [Google Scholar]
- 61.Sarenac-Vulovic TS, Mirjana A, Janicijevic Petrovic MA, et al. Systemic manifestations of pseudoexfoliation. Ser J Exp Clin Res. 2014;15:29–32. [Google Scholar]
- 62.Singham NV, Zahari M, Peyman M, Prepageran N, Subrayan V. Association between ocular pseudoexfoliation and sensorineural hearing loss. J Ophthalmol. 2014;2014:825936. doi: 10.1155/2014/825936. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Cumurcu T, Dorak F, Cumurcu BE, Erbay LG, Ozsoy E. Is there any relation between pseudoexfoliation syndrome and Alzheimer's type dementia? Semin Ophthalmol. 2013;28:224–9. doi: 10.3109/08820538.2013.793726. [DOI] [PubMed] [Google Scholar]
- 64.Linnér E, Popovic V, Gottfries CG, Jonsson M, Sjögren M, Wallin A. The exfoliation syndrome in cognitive impairment of cerebrovascular or Alzheimer's type. Acta Ophthalmol Scand. 2001;79:283–5. doi: 10.1034/j.1600-0420.2001.790314.x. [DOI] [PubMed] [Google Scholar]
- 65.Turgut Coban D, Cakir T, Erol MK, Dogan G, Dogan B, Bilgilisoy Filiz M, et al. Electroneuromyographic findings in pseudoexfoliation syndrome. Int Ophthalmol. 2018;38:705–12. doi: 10.1007/s10792-017-0520-8. [DOI] [PubMed] [Google Scholar]
- 66.Batur M, Seven E, Tanrıkulu M, Ekin S, Tekin S, Yasar T. Pulmonary functions in pseudoexfoliation syndrome. Clin Respir J. 2018;12:2271–6. doi: 10.1111/crj.12903. [DOI] [PubMed] [Google Scholar]
- 67.Yaşar E, Yıldırım N, Atalay E. Pseudoexfoliation syndrome and antidepressant drug use. Turk J Ophthalmol. 2019;49:1–5. doi: 10.4274/tjo.galenos.2018.06887. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Cumurcu T, Cumurcu BE, Celikel FC, Etikan I. Depression and anxiety in patients with pseudoexfoliative glaucoma. Gen Hosp Psychiatry. 2006;28:509–15. doi: 10.1016/j.genhosppsych.2006.09.004. [DOI] [PubMed] [Google Scholar]
- 69.Scharfenberg E, Rauscher FG, Meier P, Hasenclever D. Pseudoexfoliation syndrome: Analysis of systemic comorbidities of 325 PEX-positive patients compared with 911 PEX-negative patients. Graefes Arch Clin Exp Ophthalmol. 2019;257:2471–80. doi: 10.1007/s00417-019-04438-4. [DOI] [PubMed] [Google Scholar]
- 70.Gokce SE, Gokce MI. Relationship between pseudoexfoliation syndrome and erectile dysfunction: A possible cause of endothelial dysfunction for development of erectile dysfunction. Int Braz J Urol. 2015;41:547–51. doi: 10.1590/S1677-5538.IBJU.2014.0273. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Vardhan SA, Haripriya A, Ratukondla B, Ramulu P, Shivakumar C, Nath M, et al. Association of Pseudoexfoliation With Systemic Vascular Diseases in a South Indian Population. JAMA Ophthalmol. 2017;135:348–54. doi: 10.1001/jamaophthalmol.2017.0064. [DOI] [PubMed] [Google Scholar]
- 72.Alpaslan M, Karalezli A, Borazan M, Köktekir BE, Müderrisoğlu IH. Decreased aortic root elasticity-as a novel systemic manifestation of the pseudoexfoliation syndrome: An observational study. Anadolu Kardiyol Derg. 2012;12:483–7. doi: 10.5152/akd.2012.155. [DOI] [PubMed] [Google Scholar]
- 73.Yüksel N, Anik Y, Kiliç A, Karabaş V, Demirci A, Cağlar Y. Cerebrovascular blood flow velocities in pseudoexfoliation. Graefes Arch Clin Exp Ophthalmol. 2006;244:316–21. doi: 10.1007/s00417-004-0942-7. [DOI] [PubMed] [Google Scholar]
- 74.Yüksel N, Anik Y, Altintaş O, Onur I, Cağlar Y, Demirci A. Magnetic resonance imaging of the brain in patients with pseudoexfoliation syndrome and glaucoma. Ophthalmologica. 2006;220:125–30. doi: 10.1159/000090578. [DOI] [PubMed] [Google Scholar]
- 75.Kocabeyoglu S, Mocan MC, Irkec M, Pinar A, Bozkurt B, Orhan M. Serum vitamin D deficiency and its association with systemic disease in exfoliation syndrome. Eur J Ophthalmol. 2013;23:526–31. doi: 10.5301/ejo.5000246. [DOI] [PubMed] [Google Scholar]
- 76.Kan E, Yılmaz A, Demirağ MD, Çalık M. Is Pseudoexfoliation Syndrome a Risk Factor for Cerebro Vascular Disease? Semin Ophthalmol. 2017;32:153–6. doi: 10.3109/08820538.2015.1009559. [DOI] [PubMed] [Google Scholar]
- 77.Chung H, Arora S, Damji KF, Weis E. Association of pseudoexfoliation syndrome with cardiovascular and cerebrovascular disease: A systematic review and meta-analysis. Can J Ophthalmol. 2018;53:365–72. doi: 10.1016/j.jcjo.2017.10.039. [DOI] [PubMed] [Google Scholar]
- 78.Rumelaitienė U, Žaliūnienė D, Špečkauskas M, Tamošiūnas A, Radišauskas R, Jusevičiūtė E, et al. Link of ocular pseudoexfoliation syndrome and vascular system changes: Results from 10-year follow-up study. Int Ophthalmol. 2020;40:957–66. doi: 10.1007/s10792-019-01262-x. [DOI] [PubMed] [Google Scholar]
- 79.Djordjevic-Jocic J, Jovanovic P, Bozic M, Tasic A, Rancic Z. Prevalence and early detection of abdominal aortic aneurysm in pseudoexfoliation syndrome and pseudoexfoliation glaucoma. Curr Eye Res. 2012;37:617–23. doi: 10.3109/02713683.2012.665120. [DOI] [PubMed] [Google Scholar]
- 80.Sarenac Vulovic TS, Pavlovic SM, Jakovljevic VLj, Janicijevic KB, Zdravkovic NS. Nitric oxide and tumour necrosis factor alpha in the process of pseudoexfoliation glaucoma. Int J Ophthalmol. 2016;9:1138–42. doi: 10.18240/ijo.2016.08.09. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Wang W, He M, Zhou M, Zhang X. Ocular pseudoexfoliation syndrome and vascular disease: A systematic review and meta-analysis. PLoS One. 2014;9:e92767. doi: 10.1371/journal.pone.0092767. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Yüksel B, Schlötzer-Schrehardt U, Pehlivan O, Topaloglu E. A 13-year-old girl with presumed pseudoexfoliation. Acta Ophthalmol Scand. 2005;83:626–7. doi: 10.1111/j.1600-0420.2005.00508.x. [DOI] [PubMed] [Google Scholar]
- 83.Konstas AG, Ritch R, Bufidis T, Morales J, Qi Y, Streeten BW. Exfoliation syndrome in a 17-year-old girl. Arch Ophthalmol. 1997;115:1063–7. doi: 10.1001/archopht.1997.01100160233014. [DOI] [PubMed] [Google Scholar]
- 84.Küchle M, Naumann GO. Occurrence of pseudoexfoliation following penetrating keratoplasty for keratoconus. Br J Ophthalmol. 1992;76:98–100. doi: 10.1136/bjo.76.2.98. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Horven I, Hutchinson BT. Exfoliation syndrome. Case reports of 31 and 35-year-old patients. Acta Ophthalmol (Copenh) 1967;45:294–8. doi: 10.1111/j.1755-3768.1967.tb06493.x. [DOI] [PubMed] [Google Scholar]
- 86.Konstas AG, Williamson TH. Coexistence of exfoliation syndrome, previous iris surgery and heterochromia. Acta Ophthalmol Scand. 1992;112:850–2. doi: 10.1111/j.1755-3768.1993.tb08614.x. [DOI] [PubMed] [Google Scholar]
- 87.Sampaolesi R, Casiraghi JF, Geria R. The occurrence of exfoliation syndrome after penetrating keratoplasty: A report of three cases. Klin Monatsbl Augenheilkd. 1995;206:8–9. [Google Scholar]
- 88.Sugar HS, Harding C, Barsky D. The exfoliation syndrome. Ann Ophthalmol. 1976;8:1165–81. [PubMed] [Google Scholar]
- 89.Fakhraie G, Mohammadi M, Moghimi S. Unilateral pseudoexfoliation in two young patients with history of iris trauma and associated intraocular surgery. Iran J Ophthalmol. 2012;24:57–60. [Google Scholar]
- 90.Amini H, Daneshvar R, Eslami Y, Moghimi S, Amini N. Early-onset pseudoexfoliation syndrome following multiple intraocular procedures. J Ophthalmic Vis Res. 2012;7:190–6. [PMC free article] [PubMed] [Google Scholar]
- 91.Kumar PS, Rao A, Senthil S. Premature expression of pseudoexfoliation syndrome with presenile cataract in a 28-year-old lady. J Glaucoma. 2019;28:e115–7. doi: 10.1097/IJG.0000000000001219. [DOI] [PubMed] [Google Scholar]
- 92.Bartholomew RS. Pseudo-capsular exfoliation in the Bantu of South Africa. I. Early or pre-granular clinical stage. Br J Ophthalmol. 1971;55:693–9. doi: 10.1136/bjo.55.10.693. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Tarkkanen A. Pseudoexfoliation of the lens capsule. A clinical study of 418 patients with special reference to glaucoma, cataract, and changes of the vitreous. Acta Ophthalmol Suppl. 1962;(Suppl 71):1–98. [PubMed] [Google Scholar]
- 94.Taylor HR, Hollows FC, Moran D. Pseudoexfoliation of the lens in Australian aborigines. Br J Ophthalmol. 1977;61:473–5. doi: 10.1136/bjo.61.7.473. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 95.Summanen P, Tönjum AM. Exfoliation syndrome among Saudis. Acta Ophthalmol Suppl. 1988;184:107–11. doi: 10.1111/j.1755-3768.1988.tb02639.x. [DOI] [PubMed] [Google Scholar]
- 96.Khanzada AM. Exfoliation syndrome in Pakistan. Pakistan J Ophthalmol. 1985;2:7–9. [Google Scholar]
- 97.Joannides T, Katsourakis N, Velissaropoulos P. Glaucoma capsulare. Ophthalmologica. 1961;142:160–89. [Google Scholar]
- 98.Als E. Lens exfoliation and related and related problems in Iceland. Nordic Counc Arct Med Res Rep. 1980;26:48–53. [Google Scholar]
- 99.Oliveira C, Schlötzer-Schrehardt U, Vieira G, Liebmann J, Ritch R. Early diagnosis of exfoliation syndrome in the offspring of affected patients. Acta Ophthalmol Scand. 2006;84:512–5. doi: 10.1111/j.1600-0420.2006.00670.x. [DOI] [PubMed] [Google Scholar]
- 100.McKay KM, Borkar DS, Moustafa GA, Haviland MJ, Kloek CE, PCIOL Study Group. Clinical factors affecting operating room utilization in cataract surgery: Results from the PCIOL study. J Cataract Refract Surg. 2020;46:14–9. doi: 10.1016/j.jcrs.2019.08.004. [DOI] [PubMed] [Google Scholar]
- 101.Erdoğan H, Arici DS, Toker MI, Arici MK, Fariz G, Topalkara A. Conjunctival impression cytology in pseudoexfoliative glaucoma and pseudoexfoliation syndrome. Clin Exp Ophthalmol. 2006;34:108–13. doi: 10.1111/j.1442-9071.2006.01168.x. [DOI] [PubMed] [Google Scholar]
- 102.Küchle M, Schlötzer-Schrehardt U, Naumann GO. Occurrence of pseudoexfoliative material in parabulbar structures in pseudoexfoliation syndrome. Acta Ophthalmol (Copenh) 1991;69:124–30. doi: 10.1111/j.1755-3768.1991.tb02009.x. [DOI] [PubMed] [Google Scholar]
- 103.Ringvold A. On the occurrence of pseudoexfoliation material in extrabulbar tissue from patients with pseudoexfolation syndrome of the eye. Acta Ophthalmol. 1973;51:411–8. doi: 10.1111/j.1755-3768.1973.tb06018.x. [DOI] [PubMed] [Google Scholar]
- 104.Joachim SC, Wuenschig D, Pfeiffer N, Grus FH. IgG antibody patterns in aqueous humor of patients with primary open angle glaucoma and pseudoexfoliation glaucoma. Mol Vis. 2007;13:1573–9. [PubMed] [Google Scholar]
- 105.Smoleńska-Janicowa D, Bernacka K. Relationship between exfoliation syndrome and autoimmunity. Results of the analysis of aqueous humor. Klin Oczna. 1982;84:99–100. [PubMed] [Google Scholar]
- 106.Laatikainen L. Fluorescein angiographic studies of the 7 peripapillary and perilimbal regions in simple, capsular and 8 low-tension glaucoma. Acta Ophthalmol. 1971;111(Suppl):3–83. [PubMed] [Google Scholar]
- 107.Henriquez MA, Cerrate M, Hadid MG, Cañola-Ramirez LA, Hafezi F, Izquierdo L., Jr Comparison of eye-rubbing effect in keratoconic eyes and healthy eyes using Scheimpflug analysis and a dynamic bidirectional applanation device. J Cataract Refract Surg. 2019;45:1156–62. doi: 10.1016/j.jcrs.2019.03.017. [DOI] [PubMed] [Google Scholar]
- 108.Mansour AM, Haddad RS. Corneal topography after ocular rubbing. Cornea. 2002;21:756–8. doi: 10.1097/00003226-200211000-00004. [DOI] [PubMed] [Google Scholar]
- 109.Turner DC, Girkin CA, Downs JC. The magnitude of intraocular pressure elevation associated with eye rubbing. Ophthalmology. 2019;126:171–2. doi: 10.1016/j.ophtha.2018.08.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Osuagwu UL, Alanazi SA. Eye rubbing-induced changes in intraocular pressure and corneal thickness measured at five locations, in subjects with ocular allergy. Int J Ophthalmol. 2015;8:81–8. doi: 10.3980/j.issn.2222-3959.2015.01.15. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111.McMonnies CW. Abnormal rubbing and keratectasia. Eye Contact Lens. 2007;33:265–71. doi: 10.1097/ICL.0b013e31814fb64b. [DOI] [PubMed] [Google Scholar]
- 112.Moran S, Gomez L, Zuber K, Gatinel D. A case-control study of keratoconus risk factors. Cornea. 2020;39:697–701. doi: 10.1097/ICO.0000000000002283. [DOI] [PubMed] [Google Scholar]
- 113.Ben-Eli H, Erdinest N, Solomon A. Pathogenesis and complications of chronic eye rubbing in ocular allergy. Curr Opin Allergy Clin Immunol. 2019;19:526–34. doi: 10.1097/ACI.0000000000000571. [DOI] [PubMed] [Google Scholar]
- 114.Nagaki Y, Hayasaka S, Kadoi C. Cataract progression in patients with atopic dermatitis. J Cataract Refract Surg. 1999;25:96–9. doi: 10.1016/s0886-3350(99)80018-2. [DOI] [PubMed] [Google Scholar]
- 115.Pecora L, Sibony P, Fourman S. Eye-rubbing optic neuropathy. Am J Ophthalmol. 2002;134:460–1. doi: 10.1016/s0002-9394(02)01498-8. [DOI] [PubMed] [Google Scholar]
- 116.Kothari N, Young RC, Read SP, Tutiven J, Perez VL, Flynn HW, Jr, et al. Retinal detachment associated with atopic dermatitis. Ophthalmic Surg Lasers Imaging Retina. 2017;48:513–7. doi: 10.3928/23258160-20170601-12. [DOI] [PubMed] [Google Scholar]
- 117.Bozkurt B, Yılmaz M, Meşen A, Kamış Ü, Ekinci Köktekir B, Okudan S. Correlation of corneal endothelial cell density with corneal tomographic parameters in eyes with keratoconus. Turk J Ophthalmol. 2017;47:255–60. doi: 10.4274/tjo.22800. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Mocan MC, Yilmaz PT, Irkec M, Orhan M. In vivo confocal microscopy for the evaluation of corneal microstructure in keratoconus. Curr Eye Res. 2008;33:933–9. doi: 10.1080/02713680802439219. [DOI] [PubMed] [Google Scholar]
- 119.De Maria A, Wilmarth PA, David LL, Bassnett S. Proteomic analysis of the bovine and human ciliary zonule. Invest Ophthalmol Vis Sci. 2017;58:573–85. doi: 10.1167/iovs.16-20866. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Assia EI, Apple DJ, Morgan RC, Legler UF, Brown SJ. The relationship between the stretching capability of the anterior capsule and zonules. Invest Ophthalmol Vis Sci. 1991;32:2835–9. [PubMed] [Google Scholar]
- 121.Saber HR, Butler TJ, Cottrell DG. Resistance of the human posterior lens capsule and zonules to disruption. J Cataract Refract Surg. 1998;24:536–42. doi: 10.1016/s0886-3350(98)80298-8. [DOI] [PubMed] [Google Scholar]
- 122.Guo S, Gewirtz M, Thaker R, Reed M. Characterizing pseudoexfoliation syndrome through the use of ultrasound biomicroscopy. J Cataract Refract Surg. 2006;32:614–7. doi: 10.1016/j.jcrs.2006.01.015. [DOI] [PubMed] [Google Scholar]
- 123.Ritch R, Vessani RM, Tran HV, Ishikawa H, Tello C, Liebmann JM. Ultrasound biomicroscopic assessment of zonular appearance in exfoliation syndrome. Acta Ophthalmol Scand. 2007;85:495–9. doi: 10.1111/j.1600-0420.2007.00961.x. [DOI] [PubMed] [Google Scholar]
- 124.McWhae JA, Crichton AC, Rinke M. Ultrasound biomicroscopy for the assessmentof zonules after ocular trauma. Ophthalmology. 2003;110:1340–3. doi: 10.1016/S0161-6420(03)00464-0. [DOI] [PubMed] [Google Scholar]
- 125.Kagmeni G, Nguefack-Tsague G, Ebana Mvogo SR, Ebana Mvogo C. Ophthalmological findings in Cameroonian boxers. Clin Ophthalmol. 2017;11:1121–6. doi: 10.2147/OPTH.S134173. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Delori F, Pomerantzeff O, Cox MS. Deformation of the globe under high-speed impact: It relation to contusion injuries. Invest Ophthalmol. 1969;8:290–301. [PubMed] [Google Scholar]
- 127.Knudson DV. The biomechanics of stretching. J Exerc Sci Physiother. 2006;2:3–12. [Google Scholar]
- 128.Shinzawa M, Kato N, Kasai K, Konomi K, Chai Y, Shimazaki J. Corneal cross-linking for keratoconus caused by compulsive eye rubbing in patients with Tourette syndrome: Three case reports. Medicine (Baltimore) 2019;98:e15658. doi: 10.1097/MD.0000000000015658. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 129.Dikopf MS, Chow CC, Mieler WF, Tu EY. Cataract extraction outcomes and the prevalence of zonular insufficiency in retinitis pigmentosa. Am J Ophthalmol. 2013;156:82–800. doi: 10.1016/j.ajo.2013.02.002. [DOI] [PubMed] [Google Scholar]
- 130.Mansour AM, Reinecke RD. The pop-eye phenomenon: An extreme form of the oculodigital reflex. J Clin Neuroophthalmol. 1985;5:281–2. [PubMed] [Google Scholar]
- 131.Yusuf IH, Salmon JF. Iridoschisis and keratoconus in a patient with severe allergic eye disease and compulsive eye rubbing: A case report. J Med Case Rep. 2016;10:134. doi: 10.1186/s13256-016-0914-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 132.Eiferman RA, Law M, Lane L. Iridoschisis and keratoconus. Cornea. 1994;13:78–9. doi: 10.1097/00003226-199401000-00013. [DOI] [PubMed] [Google Scholar]
- 133.Krohn DL, Garrett EE. Iridoschisis and keratoconus; report of case in a twenty-year-old man. AMA Arch Ophthalmol. 1954;52:426–32. [PubMed] [Google Scholar]
