Commentary: Elevated atrial temperature in robotic assisted mitral valve surgery: Is it significant?

Nkosi H Alvarez a, T Sloane Guy b,
PMCID: PMC8288747  PMID: 34317708

graphic file with name fx1.jpg

T. Sloane Guy, MD, MBA (left), and Nkosi H. Alvarez, MD (right)

Central Message.

Elevated right atrial temperatures found in robotic mitral value surgery may or may not be clinically significant or reflect ventricular myocardial temperatures.

See Article page 41.

Momin and colleagues1 report on the atrial temperature differences in patients undergoing open and robotic isolated mitral valve repair with single-shot antegrade del Nido cardioplegia. With a noncontact infrared thermometer, Momin and colleagues1 demonstrated that in the body of the right atrium (RA), temperatures at the end of cardioplegia administration and up to 20 minutes after aortic crossclamp were significantly lower in open mitral valve surgery than in robotic mitral valve surgery. Moreover, Momin and colleagues1 established that there was no difference in RA body temperature between open and robotic surgery 30 minutes after cardioplegia administration until cross clamp removal.

Although Momin and colleagues1 are to be commended for their findings, there remains the central question of clinical significance of the results. They found that temperatures in the RA were higher during robotic surgery than in open surgery at 3 defined intraoperative time points, with implications for potential myocardial compromise. Robotic mitral valve surgery, however, is associated with a high likelihood of valve repair and low operative mortality and morbidity,2,3 with postoperative outcomes that are similar or better than those obtained with conventional open sternotomy.3,4 Further investigation would be necessary to tell whether the differences in RA hypothermic temperature between the procedures correlate with increased myocardial oxygen consumption that is deleterious enough to produce clinically significant myocardial outcomes.

In their examination of myocardial temperature, Momin and colleagues1 measured the temperature from the RA body directly with a contactless infrared probe. RA temperature has not been proved to be an accurate surrogate for ventricular myocardial temperature, however, which traditionally has been measured via myocardial septal temperatures.5 The closed thoracic space in robotic surgery mitral procedures likely contributes to the increased RA body temperatures (less heat dissipation, radiant heat from camera light source), but it is unclear whether the temperature in the body of the RA within the operative field would reflect the temperature of the left ventricular muscle. Septal temperature measurements could in fact be easily measured during robotic surgery by placing a standard temperature probe into the ventricular septum, and this perhaps should be considered in future studies.

The findings nonetheless do provoke questions about the need to investigate further myocardial temperature during robotic cardiac surgery. One solution to the warming effect might be to apply cold crystalloid to the heart intermittently with the robotic suction irrigator to reduce myocardial temperature. In our program, we have not found that to be necessary, although we have found that the routine use of intermittent retrograde cardioplegia after the initiation of antegrade cardioplegia and redosing at an hour (half dose) may also facilitate improved myocardial protection. Nonetheless, because of increasing amounts of minimally invasive and robotic mitral valve surgery being performed, the need to further our understanding of the clinical significance of increased RA myocardial temperature and techniques to negate these effects is vital, and this area should be thoroughly explored.

Footnotes

There were no external funding sources and no author had any conflicts of interest.

Disclosures: Dr Guy discloses a financial relationship with Edwards Lifesciences, Medtronic, Verb Surgical, and Intuitive Surgical. Dr Alvarez has nothing to disclose with regard to commercial support.

References

  • 1.Momin A.A., Chemtob R.A., Lopez D.C., Gillinov A.M., Wierup P., Mick S.L. Open sternum, cooler heart: the effect of surgical approach on myocardial temperature. J Thorac Cardiovasc Surg Tech. 2020;1:41–42. doi: 10.1016/j.xjtc.2020.01.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Gillinov A.M., Mihaljevic T., Javadikasgari H., Suri R.M., Mick S.L., Navia J.L., et al. Early results of robotically assisted mitral valve surgery: analysis of the first 1000 cases. J Thorac Cardiovasc Surg. 2018;155:82–91.e2. doi: 10.1016/j.jtcvs.2017.07.037. [DOI] [PubMed] [Google Scholar]
  • 3.Suri R.M., Antiel R.M., Burkhart H.M., Huebner M., Li Z., Eton D.T., et al. Quality of life after early mitral valve repair using conventional and robotic approaches. Ann Thorac Surg. 2012;93:761–769. doi: 10.1016/j.athoracsur.2011.11.062. [DOI] [PubMed] [Google Scholar]
  • 4.Chitwood W.R., Jr., Rodriguez E., Chu M.W., Hassan A., Ferguson T.B., Vos P.W., et al. Robotic mitral valve repairs in 300 patients: a single-center experience. J Thorac Cardiovasc Surg. 2008;136:436–441. doi: 10.1016/j.jtcvs.2008.03.053. [DOI] [PubMed] [Google Scholar]
  • 5.Dearani J.A., Axford T.C., Patel M.A., Healey N.A., Lavin P.T., Khuri S.F. Role of myocardial temperature measurement in monitoring the adequacy of myocardial protection during cardiac surgery. Ann Thorac Surg. 2001;72:S2235–S2243. doi: 10.1016/s0003-4975(01)03320-3. discussion S2243-4, S2267-70. [DOI] [PubMed] [Google Scholar]

Articles from JTCVS Techniques are provided here courtesy of Elsevier

RESOURCES