Abstract
Annular rupture is a rare catastrophic event during transcatheter aortic valve replacement, often life threatening and requiring emergent surgical repair. We describe, herein, a case of contained annular rupture successfully managed percutaneously with coiling and polymer injection. This is a novel technique to manage this complication. (Level of Difficulty: Advanced.)
Key Words: annular rupture, coiling, Evolut, TAVR
Abbreviations and Acronyms: CT, computed tomography; LVOT, left ventricular outflow tract; POD, post-operative day; TAVR, transcatheter aortic valve replacement
Central Illustration
History of Presentation
We describe a 70-year-old man who presented with gastrointestinal bleeding and was found to have evidence of heart failure and severe aortic stenosis (peak/mean gradients: 125/80 mm Hg, respectively). Coronary angiography was without significant obstruction. Four-dimensional ECG-gated cardiac computed tomography (CT) angiography (Figure 1) showed a moderately calcified aortic annulus (mean diameter area-derived: 22.7 mm, perimeter-derived: 22.3 mm), a Bicuspid Seivers-1 aortic valve, and no left ventricular outflow tract (LVOT) calcium. Low-risk isolated surgical aortic valve replacement was recommended; however, the patient indicated a strong preference for transcatheter aortic valve replacement (TAVR).
Learning Objectives
-
•
To review a case of contained annular rupture occurring during post dilation after self-expanding TAVR implantation.
-
•
To recognize the imaging findings of annular rupture.
-
•
To understand the role of surgical and nonsurgical management of annular rupture.
Figure 1.

Pre-Procedure Electrocardiogram-Gated Multiplanar Computed Tomography Aortography Demonstrating a Moderately Calcified Bicuspid Aortic Valve
LC = left coronary cusp; NC = non-coronary cusp; RC = right coronary cusp.
We performed transfemoral TAVR with a 26-mm Evolut Pro+ valve (Medtronic, Minneapolis, Minnesota) after pre-dilation with 20- and 21-mm TRUE valvuloplasty balloons (Bard Peripheral Vascular, Tempe, Arizona). The residual mean gradient was 17 mm Hg—which was felt to be unacceptably high—and post-dilation with a 22-mm TRUE balloon was performed (Video 1). Thereafter, the mean gradient was 10 mm Hg. No pericardial effusion was present; however, a contained area of contrast extravasation was noted on aortography (Figure 2, Video 1). The patient remained asymptomatic and hemodynamically stable and was admitted to the cardiac care unit.
Figure 2.

Aortography After Post-Dilation
Aortography after post dilation demonstrating a well-expanded valve frame with patent right coronary artery (A), left main coronary artery (B), and an area of contrast extending outside of the valve frame consistent with contained annular rupture (arrow).
Past Medical History
Prior to presentation, there was no prior medical or surgical history.
Differential Diagnosis
The differential diagnosis of contrast extravasation from the aorta or LVOT to the extraluminal space is limited and includes contained or uncontained aortic root and LVOT rupture.
Investigations
On post-operative day (POD) 2, a CT scan showed a 1.1 × 0.8 × 0.7 cm opacified pseudoaneurysm inferior to the right coronary cusp compressing the right coronary artery (Figure 3). Serial CT scan on POD 6 remained unchanged, and the patient was discharged. A repeat CT scan performed empirically on POD 23 to assess for stability showed enlargement of the pseudoaneurysm. He remained asymptomatic. Surgical correction was recommended; however, the patient declined unless necessary. We planned for a percutaneous repair with surgical bailout during the same procedure if unsuccessful.
Figure 3.
Computed Tomography Images of Contained Annular Rupture
Computed tomography images of aortic valve showing a contained outpouching (A) at the inferior aspect of the valve cage below the right coronary artery (B). The arrows point to the “contained outpouching.”
Management
On POD 45, the patient was placed under general anesthesia in our hybrid operating room. Right coronary artery angiography demonstrated new proximal stenosis from extrinsic compression (Figure 4); however, the patient remained without signs of ischemia. We crossed the aortic valve bioprosthesis in a retrograde fashion and exchanged to a Simmons 1 catheter (Cordis Medial, Santa Clara, California), which was manipulated to look up toward the LVOT, but we were unable to lodge the catheter tip outside of the inferior margin of the valve scaffold in a location under the right coronary cusp. Under transesophageal echocardiography and fluoroscopic guidance, the tip of the Simmons catheter was instead placed behind the valve cage at its inferior margin below the left main coronary artery, and a Choice PT Extra Support 0.014-inch coronary guidewire (Boston Scientific, Marlborough, Massachusetts) was advanced outside of the valve frame and used to direct a Prowler Plus 0.021-inch neurovascular microcatheter (Johnson & Johnson, New Brunswick, New Jersey) into the pseudoaneurysm (Video 2).
Figure 4.
Fluoroscopic Images of Annular Rupture Repair Procedure
(A) Right coronary angiography. (B) Aortic root angiograph did not demonstrate the outpouching (C) Infra-annular ventriculography of the LVOT from within the Evolut Pro + valve frame did not demonstrate the expected outpouching below the right coronary artery secondary to the skirt, which surrounds the valve cage below the neoannulus. (D) left anterior oblique projection demonstrating the tip of the Simmons 1 catheter behind the valve frame at a location under the left main coronary artery, the only place it could be stably positioned behind the valve frame. From the catheter, a Prowler Plus microcatheter (Johnson & Johnson, New Brunswick, New Jersey) guided by Choice PT Extra Support coronary guidewire (Boston Scientific, Marlborough, Massachusetts) is advanced anteriorly around the outside of the valve frame and directed toward the expected location of the outpouching. Contrast injections through the microcatheter were able to fill the outpouching. (E) The first of 4 nylon-fibered helical Concerto coils (Medtronic, Minneapolis, Minnesota) is delivered to the contained rupture. (F) Final result after coiling and injection of Onyx LD ethylene-vinyl alcohol copolymer glue (Medtronic).
The Prowler Plus microcatheter delivered two 5 × 20 mm and two 4 × 12 nylon-fibered helical detachable Concerto coils (Medtronic) into the outpouching. We then injected 0.3 ml of Onyx LD ethylene-vinyl alcohol copolymer (Medtronic). At the conclusion, there was no extravasation of contrast into pseudoaneurysm (Central Illustration, Video 2). The patient was discharged the following day and remains asymptomatic.
Central Illustration.
Percutaneous Repair of a Contained Annular Rupture
Pre-procedure: Diagram and fluoroscopic image demonstrate an outpouching in the aortic root (arrows) representing a contained annular rupture. Post-Procedure: Diagram and fluoroscopic image demonstrate successful repair of the contained annular rupture and exclusion from the aorta using coil placement and polymer injection.
Discussion
Uncontained annular rupture is estimated to occur in 0.4% of TAVR cases (1, 2, 3, 4). Risk factors have been described including subannular LVOT calcification, balloon-expandable valve oversizing, aggressive balloon post-dilation, and bicuspid anatomy, whereas the use of multislice CT has improved rates of TAVR complications including rupture (5,6). Uncontained rupture is managed with emergent surgery; however, there are prior case reports of the use of coil embolization, N-butyl-2-cyanoacrylate-based glue, and an Amplatzer Vascular Plug for management of annular rupture with hemodynamic collapse (7, 8, 9, 10).
Contained annular rupture is more common than uncontained rupture, occurring in 1.2% to 4.6% of TAVR cases (11,12) and is associated with more favorable short and long-term outcomes (5,11, 12, 13, 14). Notably, all patients in these prior series were implanted with balloon-expandable valves. For contained rupture, a “watchful waiting” approach is recommended (3, 4, 5,15).
Percutaneous management of annular rupture with a self-expanding valve presents unique challenges as the valve scaffold is longer, complicating visualization and reaccess. We are aware of 1 other case where a percutaneous strategy was used (9). In that case, the rupture was uncontained and the injury was accessible from the left coronary cusp with an XB-LAD guiding catheter (Cordis, Santa Clara, California) in the standard fashion for coronary reaccess after TAVR.
Follow-Up
Follow-up cardiac CTA at 2 months post-coiling showed obliteration of pseudoaneurysm without extravasation of contrast. The right coronary artery showed no progression of extrinsic compression, and the patient remained free of symptoms of ischemia.
Conclusions
Annular rupture may occur with self-expanding valves, typically during pre- or post-dilation. In this case, we describe a case of annular rupture managed with an endovascular strategy.
Author Relationship With Industry
Dr. Laham has served as a consultant for Medtronic. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
Footnotes
The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the JACC: Case Reportsauthor instructions page.
Appendix
For supplemental videos, please see the online version of this paper.
Appendix
Fluoroscopy of TAVR deployment, showing constrained prosthesis toward the right coronary cusp, followed by post-dilation, and subsequent appearance contained annular rupture on completion aortography.
These fluoroscopy images show percutaneous coiling of the contained annular rupture. A Simmons 1 catheter was advanced behind the frame of the TAVR prosthesis, and used to direct a Prowler Plus microcatheter which was advanced over a Choice PT Extra Support coronary guidewire into the defect. Though the microcatheter we delivered several helical Concerto coils and Onyx LD ethylene-vinyl alcohol copolymer glue.
References
- 1.Pasic M., Unbehaun A., Buz S., Drews T., Hetzer R. Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches, and prevention. J Am Coll Cardiol Intv. 2015;8:1–9. doi: 10.1016/j.jcin.2014.07.020. [DOI] [PubMed] [Google Scholar]
- 2.Walther T., Hamm C.W., Schuler G. Perioperative results and complications in 15,964 transcatheter aortic valve replacements: prospective data from the GARY Registry. J Am Coll Cardiol. 2015;65:2173–2180. doi: 10.1016/j.jacc.2015.03.034. [DOI] [PubMed] [Google Scholar]
- 3.Masson J.-B., Kovac J., Schuler G. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. J Am Coll Cardiol Intv. 2009;2:811–820. doi: 10.1016/j.jcin.2009.07.005. [DOI] [PubMed] [Google Scholar]
- 4.Langer N.B., Hamid N.B., Nazif T.M. Injuries to the aorta, aortic annulus, and left ventricle during transcatheter aortic valve replacement: management and outcomes. Circ Cardiovasc Interv. 2017;10 doi: 10.1161/CIRCINTERVENTIONS.116.004735. [DOI] [PubMed] [Google Scholar]
- 5.Barbanti M., Yang T.-H., Rodès C.J. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128:244–253. doi: 10.1161/CIRCULATIONAHA.113.002947. [DOI] [PubMed] [Google Scholar]
- 6.Mylotte D., Lefevre T., Søndergaard L. Transcatheter aortic valve replacement in bicuspid aortic valve disease. J Am Coll Cardiol. 2014;64:2330–2339. doi: 10.1016/j.jacc.2014.09.039. [DOI] [PubMed] [Google Scholar]
- 7.Azarrafiy R., Albuquerque F.N., Carrillo R.G., Cohen M.G. Coil embolization to successfully treat annular rupture during transcatheter aortic valve replacement. Catheter Cardiovasc Interv. 2018;92:1205–1208. doi: 10.1002/ccd.27546. [DOI] [PubMed] [Google Scholar]
- 8.Pignatelli A., Pestrichella V., Contegiacomo G., Navarese E.P. Percutaneous treatment of aortic root rupture after transcatheter aortic valve replacement procedure. J Cardiovasc Med (Hagerstown) 2020;21:158–160. doi: 10.2459/JCM.0000000000000879. [DOI] [PubMed] [Google Scholar]
- 9.Chakravarty Tarun, Cox Justin, Abramowitz Yigal. Percutaneous management of aortic root rupture during transcatheter aortic valve replacement with coil embolization. Circ Cardiovasc Interv. 2018;11 doi: 10.1161/CIRCINTERVENTIONS.117.005590. [DOI] [PubMed] [Google Scholar]
- 10.Piliero N., Thony F., Vanzetto G., Barone-Rochette G. Gluing of an aortic perforation during transcatheter aortic valve replacement: an alternative treatment for annular rupture? J Am Coll Cardiol Intv. 2015;8:2037–2038. doi: 10.1016/j.jcin.2015.08.027. [DOI] [PubMed] [Google Scholar]
- 11.Breitbart P., Minners J., Pache G. Outcomes in patients with contained ruptures of the aortic annulus after transcatheter aortic valve implantation with balloon-expandable devices. EuroIntervention. 2017;13:1300–1302. doi: 10.4244/EIJ-D-17-00347. [DOI] [PubMed] [Google Scholar]
- 12.Blanke P., Reinöhl J., Schlensak C. Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root. Circ Cardiovasc Interv. 2012;5:540–548. doi: 10.1161/CIRCINTERVENTIONS.111.967349. [DOI] [PubMed] [Google Scholar]
- 13.Aminian A., Lalmand J., Dolatabadi D. Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2013;81:E72–E75. doi: 10.1002/ccd.24363. [DOI] [PubMed] [Google Scholar]
- 14.Subban V., Incani A., Clarke A. Conservative management and resolution of a contained rupture of aortic annulus following transcatheter valve replacement. J Am Coll Cardiol Intv. 2013;6:e33–e34. doi: 10.1016/j.jcin.2013.02.012. [DOI] [PubMed] [Google Scholar]
- 15.Lange R., Bleiziffer S., Piazza N. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg. 2011;40:1105–1113. doi: 10.1016/j.ejcts.2011.03.022. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Fluoroscopy of TAVR deployment, showing constrained prosthesis toward the right coronary cusp, followed by post-dilation, and subsequent appearance contained annular rupture on completion aortography.
These fluoroscopy images show percutaneous coiling of the contained annular rupture. A Simmons 1 catheter was advanced behind the frame of the TAVR prosthesis, and used to direct a Prowler Plus microcatheter which was advanced over a Choice PT Extra Support coronary guidewire into the defect. Though the microcatheter we delivered several helical Concerto coils and Onyx LD ethylene-vinyl alcohol copolymer glue.