Vijay S. Patel, MD, and Richard Lee, MD, MBA
Central Message.
Despite improvements in techniques, technologies, outcomes, and safety of MIS treatment of AF, challenges persist to close the “gaps” and gain widespread acceptance among the surgical community.
See Article page 34.
Current guidelines recommend invasive endocardial catheter ablation (CA) for patients with atrial fibrillation (AF) refractory to medical management; however, CA has poor long-term outcomes, particularly in the most challenging patients with persistent AF or patients with longstanding persistent AF.1 The Cox-maze III (CM-III) open cut-and-sew surgical procedure has significantly better long-term outcomes in this challenging group of patients and is considered the gold standard of surgical ablation (SA).2 Despite numerous single-center studies reporting similar long-term outcomes, the CM-III procedure failed to gain widespread acceptance due to its highly invasive and complex technique requiring cardiopulmonary bypass. Instead, the surgical community embarked on efforts to develop alternative minimally invasive (MIS) SA techniques with and without cardiopulmonary bypass, embracing new technologies to create transmural ablation lesions replacing the cut-and-sew procedure, exceed CA outcomes with acceptable safety profile, and duplicate the CM-III outcomes.3, 4, 5, 6, 7
The article by Zheng and colleagues8 is a feasibility study to move the needle further toward the classic CM-III anatomy-based bi-atrial lesions using an MIS beating-heart thoracoscopic SA technique combined with single-stage endocardial CA. In a cohort of 27 patients, freedom from atrial tachyarrhythmia (AT) with or without antiarrhythmic drugs after a single hybrid procedure was 64% and 60% at 12 months, respectively, and the addition of a redo CA increased the freedom from atrial tachyarrhythmia to 77.8% and 74.1% at 12 months, respectively. The left and right atrial size decreased in patients maintaining sinus rhythm. The hybrid concept is not unique, although the bi-atrial surgical technique is an improvement to previously reported primarily left atrial thoracoscopic SA albeit with variable additional lesions interspersed between studies. Their outcomes are acceptable but lack significant improvement to outcomes reported in the literature by numerous other centers.9 The safety profile is admirable compared with other reports. The authors acknowledge the important limitations of their preliminary experience, including a small sample size with short follow-up preventing over-reaching conclusions of efficacy, challenges in their technique to achieve reliable mitral isthmus lesions, abandoned right atrium endocardial ablation in most patients, and the unreliability of assuring transmural linear lesions with the bipolar unidirectional radiofrequency device. A concomitant single-step hybrid CA procedure is obligatory, given the premise of this study; however, a 2-staged hybrid approach may avoid unnecessary CA procedure in some patients, reliably address pulmonary vein reconnection, and perform staged additional ablation lesions for failed index MIS thoracoscopic SA as noted by Lee and colleagues.10 The authors' inability to approximate the CM-III ablation lesions and desired outcome is not unique to this study, given the technical challenges associated with an MIS beating-heart thoracoscopic ablation with or without complementary hybrid CA, the currently available alternative ablation technology to assure transmural lesions, the paucity of data on mechanisms of ablation failure to refine procedural techniques, heterogeneous hybrid ablation protocols in reported studies, absence of convincing literature to support single-step versus 2-stage hybrid approach, incomplete understanding of the pathogenesis of AF, and lack of convincing randomized controlled trials. Perhaps, their contribution will rekindle future studies among the surgical community to embrace a bi-atrial ablation protocol also proposed by Cox and colleagues11 in their template for the “hybrid Cox-maze-IV” procedure for longstanding persistent AF.
Footnotes
Disclosures: The authors reported no conflicts of interest.
The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest.
References
- 1.Pak H.N. Catheter ablation of long-standing persistent atrial fibrillation: a reckless challenge or a way to real cure? Korean Circ J. 2019;49:134–145. doi: 10.4070/kcj.2018.0418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Prasad S.M., Maniar H.S., Camillo C.J., Schuessler R.B., Boineau J.P., Sundt T.M., III, et al. The Cox maze III procedure for atrial fibrillation: long-term efficacy in patients undergoing lone versus concomitant procedures. J Thorac Cardiovasc Surg. 2003;126:1822–1828. doi: 10.1016/s0022-5223(03)01287-x. [DOI] [PubMed] [Google Scholar]
- 3.Harky A., Bithas C., Chan J.S.K., Snosi M., Pousios D., Muir A.D. Surgical treatment of atrial fibrillation: cutting through the edges. Braz J Cardiovasc Surg. 2020;35:375–386. doi: 10.21470/1678-9741-2019-0057. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ruaengsri C., Schill M.R., Khiabani A.J., Schuessler R.B., Melby S.J., Damiano R.J., Jr. The Cox-maze IV procedure in its second decade: still the gold standard? Eur J Cardiothorac Surg. 2018;53(suppl_1):i19–i25. doi: 10.1093/ejcts/ezx326. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Ad N., Holmes S.D., Friehling T. Minimally invasive stand-alone Cox maze procedure for persistent and long-standing persistent atrial fibrillation: perioperative safety and 5-year outcomes. Circ Arrhythm Electrophysiol. 2017;10:e005352. doi: 10.1161/CIRCEP.117.005352. [DOI] [PubMed] [Google Scholar]
- 6.Sirak J.H., Schwartzman D. Interim results of the 5-box thoracoscopic maze procedure [Erratum in: Ann Thorac Surg. 2013;95:1140] Ann Thorac Surg. 2012;94:1880–1884. doi: 10.1016/j.athoracsur.2012.06.010. [DOI] [PubMed] [Google Scholar]
- 7.Maesen B., Pison L., Vroomen M., Luermans J.G., Vernooy K., Maessen J.G., et al. Three-year follow-up of hybrid ablation for atrial fibrillation. Eur J Cardiothorac. 2018;53:i26–i32. doi: 10.1093/ejcts/ezy117. [DOI] [PubMed] [Google Scholar]
- 8.Zheng Z., Yao Y., Li H., Zheng L., Liu S., Lin H., et al. Simultaneous hybrid maze procedure for long-standing persistent atrial fibrillation with dilated atrium. J Thorac Cardiovasc Surg Tech. 2021;5:34–42. doi: 10.1016/j.xjtc.2020.10.015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Khoynezhad A., Ellenbogen K.A., Al-Atassi T., Wang P.J., Kasirajan V., Wang X., et al. Hybrid atrial fibrillation ablation: current status and a look ahead. Circ Arrhythm Electrophysiol. 2017;10:e005263. doi: 10.1161/CIRCEP.117.005263. [DOI] [PubMed] [Google Scholar]
- 10.Lee R., McCarthy P.M., Passman R.S., Kruse J., Malaisrie S.C., McGee E.C., et al. Surgical treatment for isolated atrial fibrillation minimally invasive vs classic cut and sew maze. Innovations (Phila) 2011;6:373–377. doi: 10.1097/IMI.0b013e318248f3f4. [DOI] [PubMed] [Google Scholar]
- 11.Cox J.L., Churyla A., Malaisrie S.C., Pham D.T., Kruse J., Kislitsina O.N., et al. A Hybrid maze procedure for long-standing persistent atrial fibrillation. Ann Thorac Surg. 2019;107:610–618. doi: 10.1016/j.athoracsur.2018.06.064. [DOI] [PubMed] [Google Scholar]