Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2021 Jul 23;11:15064. doi: 10.1038/s41598-021-93749-w

An efficient electrochemical sensing of hazardous catechol and hydroquinone at direct green 6 decorated carbon paste electrode

K Chetankumar 1, B E Kumara Swamy 1,, S C Sharma 2,3,4,, S A Hariprasad 3
PMCID: PMC8302748  PMID: 34301960

Abstract

In this proposed work, direct green 6 (DG6) decorated carbon paste electrode (CPE) was fabricated for the efficient simultaneous and individual sensing of catechol (CA) and hydroquinone (HY). Electrochemical deeds of the CA and HY were carried out by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at poly-DG6-modfied carbon paste electrode (Po-DG6-MCPE). Using scanning electron microscopy (SEM) studied the surface property of unmodified CPE (UCPE) and Po-DG6-MCPE. The decorated sensor displayed admirable electrocatalytic performance with fine stability, reproducibility, selectivity, low limit of detection (LLOD) for HY (0.11 μM) and CC (0.09 μM) and sensor process was originated to be adsorption-controlled phenomena. The Po-DG6-MCPE sensor exhibits well separated two peaks for HY and CA in CV and DPV analysis with potential difference of 0.098 V. Subsequently, the sensor was practically applied for the analysis in tap water and it consistent in-between for CA 93.25–100.16% and for HY 97.25–99.87% respectively.

Subject terms: Natural hazards, Chemistry

Introduction

Dihydroxybenzene (DHB) isomers like catechol (CA) and hydroquinone (HY) are extensively utilized in the agronomic practices and chemical industry, such as tanning, plastic, pesticides, dyes, rubber, pharmaceuticals and so forth16. Nevertheless, DHB is venomous and hard to degrade, menacing the environment and crippling animal and human health, it leads to incurring the harm to kidney and liver function affected by CA and HY have also been reported712. In addition, simultaneously sensing of CA and HY is tough because they mutual interfere with each other during their identification because of their similar structures, properties and coexistence13, 14. Consequently, the fabrication of simple, selective, speedy, accurate and sensitive analytical method was needed for the detection and quantifying of CA and HY15, 16. Up to now, numerous techniques have been testified for sensing of CA and HY, such as spectrophotometry, capillary electrochromatography (CEC), high-performance liquid chromatography (HPLC), gas chromatography/mass spectrometry (GC/MS), fluorescence (FL, chemiluminescence (CL) and electroanalytical method1724. Amongst, the electrochemical analysis has owing prominent in current years to its advantages like simplicity, portability, low cost, time saving, convenient operation, speedy response, as well as high efficiency, sensitivity and selectivity2530.

In current decade, polymer modified electrodes (PMEs) have accomplished more attention due to their homogeneity, reproducibility, good constancy and strong adherence to electrode surface3134. Direct green 6 (DG6) mainly utilized in fibers, soap, leather, regenerated cellulose fibers film shading, colouring of paper and also employed in the production of colour pigment sediment35, 36 (Scheme 1). The fabrication of the modified electrode was carried out by electropolymerization of DG6 using CV technique and applied for the sensing of CA and HY in presence of biological pH 7.4.

Scheme 1.

Scheme 1

Structure of Direct green 6.

Experimental section

Equipment and chemicals

Voltammetric analysis was tested by CV and DPV performances expending a traditional three-electrode cell of CH Instrument-660 (CHI-660c) electrochemical workstation. UCPE and Po-DG6-MCPE were employed as working, saturated calomel electrode (SCE) as a reference and a platinum wire as a counter electrode individually.

HY and CA procured from Sigma-Aldrich and standard solutions (25 × 10–4 M) was prepared in double distilled water. DG6, sodium dihydrogen phosphate (NaH2PO4), disodium hydrogen phosphate (Na2HPO4) were gained from Merck chemicals of AR grade and all aqueous solution were prepared with double distilled water. All the reagents are utilized in this study with analytical grade and used as received.

Results and discussion

Preparation of UCPE and Po-DG6-MCPE

The UCPE was fabricated by blending of graphite powder and silicone oil in the ratio 70:30 (w/w) for about 30 min and get homogeneous mixture. The gotten blend was then filled with homemade Teflon cavity consuming 3 mm internal diameter and cooper wire was utilized for the electrical contact. The pre-treated carbon paste electrode (PCPE) was constructed by electrochemical oxidised by cycling the potential between − 0.6 to 1.0 V in 0.1 M NaOH with speed rate of 0.05 V s–1 at 10 multiple cycle.

Electro-polymerisation manner was applied for the constructed fabricated electrode. DG6 (1.8 mM) was carried on the surface of UCPE using cyclic voltammetry in the existence of 0.1 M NaOH (supporting media) and cyclic the potential scanned between − 0.6 to 1.0 V with speed rate 0.05 V s–1 for 10 polymerization cycles as elucidates in Fig. 1a. As witnessed from the figure, the peak current gradually boosted with increasing the polymer cycles this endorses the growth of polymeric films on UCPE37. The deposition of DG6 on UCPE was carried by changing the polymer series 5 to 25 cycles (Fig. 1b) and applied to identify the electrochemical reactions towards CA in 0.2 M PBS of pH 7.4. By perceiving the Fig. 1b, the Ipa was enhanced upto ten cycles and after 15 cycles it decreases slightly and sudden increment in Ipa for 20 and 25 cycles. Therefore, ten cycles of electro-polymerization were selected and optimised for the fabrication of modified electrode.

Figure 1.

Figure 1

(a) Electropolymerization of 1.8 mM DG6 on the surface of UCPE in presence of 0.1 M NaOH with speed rate 0.05 V s−1 for 10 multiple cycles. (b) Graph of Ipa versus a number of varied electropolymerization cycles.

Characteristics and surface property of Po-DG6-MCPE

The characteristic property of Po-DG6-MCPE was verified using K4[Fe(CN)6] (25 × 10–3 M) as redox probe in 1 M KCl (supporting media). Figure 2 signifies the gotten cyclic voltammograms (CVs) for UCPE (scattered line) and hard-line curve for the Po-DG6-MCPE with speed rate 0.05 V s–1. At UCPE, it implies small peak current and in the similar form Po-DG6-MCPE reveals superior boost in peak current than UCPE. Therefore, this development in peak current donated substantial increase in electroactive surface area. This active surface area of the electrode was identified using Randles–Sevick’s Eq. (1) 38. Compared to Po-DG6-MCPE (0.061 cm2) the UCPE (0.030 cm2) was consumed less electroactive surface area. The approximate adhered modifier thickness or surface average concentration on UCPE was calculated by utilising Eq. (2) 39 and got at 0.271 × 10−10 M cm−2.

Figure 2.

Figure 2

CVs recorded for 1 mM K4[Fe(CN)6] at UCPE (scattered line) and Po-DG6-MCPE (hard line) at speed rate of 50 mV s−1 using 1 M KCl.

The surface changes of before and after fabrication of UCPE was characterized by SEM using ZEISS Ultra-55. The Fig. 3a and b exposes the achieved SEM pictures of UCPE and Po-DG6-MCPE. In UCPE, the films portray asymmetrical designed flakes of CPE. After modification of DG6, the film was uniformly associated on the superficial of UCPE. This morphological variation on the electrode surface lead to rise in the electro-active surface area and favoured good electrocatalytic accomplishment40, 41.

Ip=2.69×105n3/2AD1/2Coν1/2 1
Ip=n2F2AΓν/4RT 2

where A is the area of working electrode (cm2), C0 is the concentration of the electroactive species (mol/cm3), n is the electrons transformed, ν is the sweep rate (V/s), D is the diffusion coefficient (cm2 s−1), Ip is the peak current, Γ (M/cm2) is the surface average concentration and R, F, T are the physical constants.

Figure 3.

Figure 3

SEM images for (a) BCPE and (b) Po-DG6-MCPE.

Electrocatalytic performance of CA at Po-DG6-MCPE

The sensing proficiency of Po-DG6-MCPE towards the CA was scanned by CV technique as most sensitive and precise voltammetric technique. In Fig. 4 the dotted line (green), dashed line (pink) and hard line (red) depicts CVs for UCPE, PCPE and Po-DG6-MCPE for CA (10 μM) in 0.2 M PBS with speed rate of 0.05 V s−1. The UCPE provides CVs with reduced and broad response and at PCPE it gave voltammetric response with poor response. Compared UCPE and PCPE the designed electrode signifies ultimate enrichment in peak current with very precise sensitivity with sharp peaks. The peak potential difference (ΔEp = Epa-Epc) was acquired at 0.153 V (BCPE), 0.095 V (PCPE) and 0.017 V (Po-DG6-MCPE) individually. At tailored electrode the electron transfer was easier than UCPE and PCPE, because where ΔEp value is inferior and transfer of electron rate will be greater. Therefore, the Po-DG6-MCPE accomplished as a good sensor and prominent for the analysis of CA. The redox response of CA was portrayed in Scheme 2.

Figure 4.

Figure 4

CVs curve for 10 µM CA at UCPE (scattered line) and Po-DG6-MCPE (dashed line) with speed rate 0.05 V s−1 using 0.2 M PBS of pH 7.4.

Scheme 2.

Scheme 2

Redox mechanism of CA and HY.

Effect of speed rate and concentration study of CA at Po-DG6-MCPE

The Po-DG6-MCPE process was assessed by changing the speed rate. Figure 5a elucidated the CVs for CA (10 μM) in presence of supporting media with altered speed rates. As seeming in figure, the redox (oxidation and reduction) peak current of CA was successively boosted as increase in the speed rate (60 to 220 mV s−1) and minute move of their peak potential to positive and negative side. The linear correlation between anodic peak current (Ipa) versus speed rate (ν) and Ipa versus square root of the speed rate was drawn in Fig. 5b and c. The gotten plot gave very fine straight line with correlation coefficient value (R2) was initiate at 0.9991 and 0.9937 correspondingly. Consequently, by spotting the overhead practical result the kinetic property of Po-DG6-MCPE was originated at adsorption controlled process42, 43. Heterogeneous rate constant (k0 in s−1) were computed by Eq. 3 and attained results are tabulated in Table 1.

ΔEp=201.39 logν/k0-301.78 3

where, k0, ΔEp, ν, is the heterogeneous rate constant in s-1, difference in peak potential, speed rate respectively.

Figure 5.

Figure 5

(a) CVs for 10 µM CA at Po-DG6-MCPE with changed speed rates (0.06–0.22 V s−1) using 0.2 M PBS of pH 7.4. (b) Plot of Ipa versus speed rate. (C) Plot of Ipa versus square root of speed rate.

Table 1.

Heterogenous rate constant for CA and HY at Po-DG6-MCPE.

Scan rate (mV s−1) ΔEp (mV) Heterogeneous rate constant (k0) s−1
CA HY CA HY
60 26 19.7 1.414 1.520
80 38.2 31.7 1.640 1.766
100 46.1 35 1.873 2.126
120 48.9 35.9 2.177 2.526
140 48 36.8 2.566 2.916
160 53 37.8 2.769 3.295
180 57.7 38.5 2.953 3.678
200 60.7 38.9 3.170 4.068
220 65.7 40.7 3.293 4.383
240 41.9 4.717

The revealing of detection sensitivity at modified electrode was assessed by utilizing CV and DPV performances. Figure 6a and b epitomizes the obtained CVs (5–45 μM) and DPVs (10–45 μM) for altered concentrations of CA in presence of pH 7.4 with speed rate of 0.05 V s−1. These figures evidently portray that the peak current was boosted noticeably when the analyte concentration was rises. Inset Fig. 6a and b indicates the correlation between Ipa and concentration of analyte with good linearity values of R2: 0.9992 and 0.9993. Utilizing the slope value (M) and standard deviation (S) of the Ipa (acquired from inset Fig. 6a and b) assessed the LLOD and LOQ employing Eqs. (4) and (5)44 for CA and gotten at 0.09 and 0.29 μM separately.

LLOD=3S/M 4
LOQ=10S/M 5

Figure 6.

Figure 6

(a) Obtained CVs for CA at Po-DG6-MCPE with varied concentration (5–45 µM) in 0.2 M PBS (pH 7.4) with speed rate of 0.05 V s−1 and inset figure is graph of Ipa versus concentration of CA. (b) DPVs recorded for varied concentration of CA (10–45 µM) at Po-DG6-MCPE and inset figure is plot of Ipa versus concentration of CA.

Optimization of pH on CA at Po-DG6-MCPE

The choice of supporting electrolytes plays major part in the electrochemical study. Figure 7a and exposes the acquired CVs for CA (10 μM) in existence of 0.2 M PBS of changed pH (6.2, 6.6, 7.0, 7.4, 7.8) with speed rate 0.05 V s−1 at Po-DG6-MCPE. As witnessed in Fig. 7a, it obviously exposed that as the pH solution was changed then the peak potential of CA was moved to more negative side. This accomplished result was proof for the directly participation of proton in the electrochemical reaction. The linear connection between Epa and varied pH of CA was clarified in inset Fig. 7b. The attained regression eqn. is expressed for CA as Epa (V) = − 0.049 pH + 0.445 (R2 = 0.9961). The acquired slope value 49 mV pH−1 was very close to the Nernstian theoretical value (59 mV), so it clearly advises the equal number of electron and proton was involved in the electrode reaction43, 45. Figure 7c portrays the plot of Ipa versus altered pH solution. By considering maximum peak current and the sensitivity pH 7.4 solution was optimised for further electrochemical exploration.

Figure 7.

Figure 7

(a) Recorded CVs for 10 µM CA at Po-DG6-MCPE in presence of altered pH. (b) Plot of Epa versus pH. (c) Plot of Ipa vs. pH.

Electrocatalytic performance of HY at Po-DG6-MCPE

The electrocatalytic sensing of HY was traced by cyclic voltammetry and Fig. 8 elucidates the attained CVs for HY (10 μM) in presence of 0.2 M PBS of pH 7.4 with speed rate 0.05 V s−1 at Po-DG6-MCPE. At BCPE (scattered row), it portrays low peak current with poor response because of sluggish electron transfer. Similarly, at established Po-DG6-MCPE (hard row) it provided superior enlargement in redox peak current with very precise sensitivity with sharp than UCPE. The ΔEp value for Po-DG6-MCPE and UCPE was gotten at 0.018 and 0.07 V respectively. Where ΔEp is lower than electron transfer rate will be greater, hence at the constructed electrode electron transfer is easier than UCPE. Thus, the Po-DG6-MCPE achieved as good sensor and prominent for the investigation of HY and redox mechanism was signifying in Scheme 2.

Figure 8.

Figure 8

CVs for 10 µM HY in 0.2 M PBS (pH 7.4) at UCPE (scattered line) and Po-DG6-MCPE (hard line) with speed rate of 50 mV s−1.

Impact of speed rate and concentration variation on HY at Po-DG6-MCPE

The speed rate study offered the essential confirmation about the electrode process. Figure 9a exhibits the gotten CVs for HY in the existence of 0.2 M PBS (pH 7.4) with various speed rate (0.06 to 0.24 V s−1). By witnessing the Fig. 9a, as the speed rates elevated the redox peak current is improved subsequently with tiny move in their peak potential to positive and negative potentials. The relationship between Ipa versus speed rate and Ipa versus square root of speed rate was plotted in Fig. 9b and c correspondingly. The plotted graph gave straight linearity with R2 value was originate at 0.9997 and 0.9984 respectively and electrode process was governed by adsorption controlled process.

Figure 9.

Figure 9

(a) CVs for 10 µM HY in 0.2 M PBS (pH 7.4) at Po-DG6-MCPE with varied speed rates (0.06–0.24 V s−1). (b) Graph of Ipa versus speed rate. (c) Graph of Ipa versus square root of speed rate.

The LLOD and LOQ was calculated utilizing Eqs. (4) and (5) for HY by applying the CV and DPV performance. Figure 10a and b epitomizes the obtained CVs (5–40 μM) and DPVs (10–45 μM) for altered concentration (5–40 μM) of HY in existence of pH 7.4 with speed rate of 0.05 V s−1. As noticed in Fig. 10a and b, the oxidation peak current of HY was growths linearly as the concentration raises and peak potential tiny swing towards negative and positive direction. The inset Fig. 10a and b portrays the connection between concentration of HY and Ipa and it gave very adequate linearity with R2 value 0.9984 and 0.9979. The LLOD and LOQ was establish at 0.11 and 0.36 μM correspondingly. The Po-DG6-MCPE offered low LLOD for CA and HY than other fabricated sensor and displayed in Table 2.

Figure 10.

Figure 10

(a) CVs curve for altered concentration of HY (5–40 µM) at Po-DG6-MCPE in 0.2 M PBS (pH 7.4) with speed rate of 0.05 V s−1 and inset figure is plot of Ipa versus concentration of HY. (b) DPVs curve for varied concentration of HY (10–45 µM) at Po-DG6-MCPE and inset figure is plot of Ipa versus concentration of HY.

Table 2.

Comparison of LLOD at Po-DG6-MCPE with other reported modified electrodes for the determination CA and HY.

Working electrode Limit of detection (µM) Reference
CC HQ
COF/MCPE 0.46 0.31 2
NCNTFs/GCE 0.12 0.17 7
PIL-MCNs/CS/GCE 0.62 1.39 8
CoFe2Se4/PCF 0.15 0.13 9
Activated GSEC 0.1 0.1 15
Pt/C60/PGE 2.97 2.19 16
Fluorescent polymer nanoparticles (FPNs) 0.33 0.21 51
CA-GCE 0.23 0.46 52
3D sulfur/nitrogen co-doped graphene 0.28 0.15 53
DCIL 0.40 0.31 54
Co3O4/MWCNTs/GCE 8.5 5.6 55
PPGE 1.32 1.17 56
PCFCuNP/GE 0.53 1.1 57
GCE/MtH-NH2 0.65 58
Poly(vanillin)/MCPE 0.95 0.99 59
GDYO/GCE 0.2 0.3 60
Po-DG6-MCPE 0.09 0.11 Present work

Simultaneous sensing capability of Po-DG6-MCPE

The simultaneous revealing of CA and HY was very challenging in mixed solution at UCPE. Because in the mixed solution they are overlapped each other due to their approximately same oxidation potential46. Thus, to validate the potentiality of designed electrode for the simultaneous exploration of CA and HY. Figure 11a discloses the gotten CVs curve for CA and HY (10 μM) in existence of 0.2 M PBS (pH 7.4) with speed rate 0.05 V s−1. The UCPE (scattered line) was failed to depicts the two oxidation peaks but gave only one oxidation peaks located at 0.258 V. Moreover, the fabricated Po-DG6-MCPE (solid streak) clearly verified the two separated oxidation peaks for CA and HY (0.15 and 0.03 V) individually with magnificent development in peak current compared to UCPE. Figure 11b exposes the DPVs for CA and HY in existence of 0.2 M PBS (pH 7.4). Here also (Fig. 11b), at UCPE it fails to separate the oxidation peaks for CA and HY but at the designed electrode it clearly depicts two well distinguish sharp peaks (0.105 and 0.014 V) with improvement in their peak current than UCPE. Therefore, the designed Po-DG6-MCPE was excellent capability for the simultaneous recognition of CA and HY.

Figure 11.

Figure 11

(a) CVs curve for simulataneous sensing of CA and HY (10 µM) in 0.2 M PBS of pH 7.4 at UCPE (scattered line) and Po-DG6-MCPE (hard line) with speed rate 0.05 V s−1. (b) DPVs for simulataneous sensing of CA and HY (10 µM) in 0.2 M PBS of pH 7.4 at UCPE (blue hard line) and Po-DG6-MCPE (saffron hard line).

Selectivity and stability of CA and HY at Po-DG6-MCPE

The efficiency and selectivity detection of CA and HY was testified at Po-DG6-MCPE by applying the DPV technique. Figure 12a represents the tracing of CA by kept the concentration of HY (20 μM) was constant. As we perceived, the peak current of CA was boosted by increasing the concentration of CA in the range 20–160 μM. Inset the Fig. 12a implies the linearity graph of Ipa versus altered concentration of CA. Likewise for HY, the concentration was altered in the range 20 to 160 μM and CA (20 μM) concentration was kept constant and signified in Fig. 12b. By witnessing the above consequence, as the concentration of analyte increased the peak current was boosted gradually but there was no variation in peak potential and peak current of constant analytes. Inset the Fig. 12b displays the linearity relationship of Ipa versus changed concentration of HY. This outcome specifies that the constant analytes are did not interfere in the analysis. Therefore, Po-DG6-MCPE have commendable selectivity and they are tested individually in mixed solution.

Figure 12.

Figure 12

(a) DPVs of CA with changed concentration (20–160 µM) in presence of HY (20 µM) and inset figure is graph of Ipa versus concentration of CA. (b) DPVs curve for varied concentartion of HY (20–160 µM) in presence of CA (20 µM) in 0.2 M PBS (pH 7.4) at Po-DG6-MCPE.

The stability of the Po-DG6-MCPE was assessed for CA (10 µM) in presence of 0.2 M PBS for 10 cycles with speed rate of 50 mV s−1 by utilizing CV system. As depicted in Fig. 13 the redox current remains steady and after accomplishment 10 multiple cycles the small reductions in their redox current was 4.57%. The percentage degradation was assessed by eqn. % degradation = Ipn/Ip147, 48, where Ip1 and Ipn are the 1st and nth cycle Ipa respectively. The retained steadiness of the Po-DG6-MCPE was 95.43% and this confirms the established electrode have magnificent stability.

Figure 13.

Figure 13

CVs of CA(10 µM) in presence of 0.2 M PBS of pH 7.4 with speed rate 0.05 V s−1 at Po-DG6-MCPE for 10 cycles.

Interference and practical analysis

The anti-interference capability of Po-DG6-MCPE were tested for CA and HY in presence of some coexisting compounds such as resorcinol, uric acid, serotonin, NaCl and KCl and CaCl2. There was no considerable interference was perceived for the analysis. Thus, the proposed Po-DG6-MCPE sensor reveals the excellent anti-interference ability.

Finally, the fashioned Po-DG6-MCPE was testified for the practical applicability of CA and HY in a local tap water sample using standard addition method49, 50. This advises the recommended electrode exposes satisfactory recovery for each sample addition and attained results are recorded in Table 3. Therefore, this result clarifies the accuracy of constructed electrode for the revealing CA and HY in tap water.

Table 3.

Recoveries of CA and HY in a local tap water sample at Po-DG6-MCPE.

Samples Add (μM) Found (μM) Recovery (%)
CA HY CA HY CA HY
Tap water 4 4 3.93 3.89 98.25 97.25
8 8 7.46 7.99 93.25 99.87
12 12 12.02 11.73 100.16 97.55
16 16 15.91 15.96 99.43 99.75

Conclusion

The proposed work reports Poly-DG6-MCPE was accomplished as a sensor for the detection of CA and HY. The surface morphology of UCPE and Po-DG6-MCPE was characterized by SEM examination. This proposed electrode exposed the strong electrocatalytic activity, high sensitivity, stability and gave improved electron transfer response than UCPE with respect to the oxidation of CA and HY. The impact of pH study, concentration variation and speed rate study was tested at fabricated electrode. The Po-DG6-MCPE involves adsorption-controlled procedure and displayed low detection limit value compared to other reported electrodes. Simultaneous firmness of CA and HY was tracked by CV method. The constructed modified electrode results in good stability, selectivity and offers satisfactory recovery of analytes. Therefore, the mentioned Po-DG6-MCPE was substantial potentiality for the specific and simultaneous investigation and this constructed electrode was utilized for the further analysis of other electro-active biomolecules.

Author contributions

All authors reviewed the revised manuscript.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

B. E. Kumara Swamy, Email: bek@kuvempu.ac.in

S. C. Sharma, Email: scsharma.bangalore@gmail.com

References

  • 1.Wang J, Yang J, Xu P, Liu H, Zhang L, Zhang S, Tian L. Gold nanoparticles decorated biochar modified electrode for the high performance simultaneous determination of hydroquinone and catechol. Sens. Actuator B Chem. 2020;306:127590. doi: 10.1016/j.snb.2019.127590. [DOI] [Google Scholar]
  • 2.Xin Y, Wang N, Wang C, Gao W, Chen M, Liu N, Duan J, Hou B. Electrochemical detection of hydroquinone and catechol with covalent organic framework modified carbon paste electrode. J. Electroanal. Chem. 2020;877:114530. doi: 10.1016/j.jelechem.2020.114530. [DOI] [Google Scholar]
  • 3.Huang R, Liao D, Chen S, Yu J, Jiang X. A strategy for effective electrochemical detection of hydroquinone and catechol: Decoration of alkalization-intercalated Ti3C2 with MOF-derived N-doped porous carbon. Sens. Actuator B Chem. 2020;320:128386. doi: 10.1016/j.snb.2020.128386. [DOI] [Google Scholar]
  • 4.Mohanadas D, Tukimin N, Sulaiman Y. Simultaneous electrochemical detection of hydroquinone and catechol using poly(3,4-ethylenedioxythiophene)/reduced graphene oxide/manganese dioxide. Synth. Met. 2019;252:76–81. doi: 10.1016/j.synthmet.2019.04.014. [DOI] [Google Scholar]
  • 5.Zhang M, Ye J, Fang P, Zhang Z, Wang C, Wu G. Facile electrochemical preparation of NaOH nanorods on glassy carbon electrode for ultrasensitive and simultaneous sensing of hydroquinone, catechol and resorcinol. Electrochim. Acta. 2019;317:618–627. doi: 10.1016/j.electacta.2019.06.006. [DOI] [Google Scholar]
  • 6.Huang R, Chen S, Yu J, Jiang X. Self-assembled Ti3C2 /MWCNTs nanocomposites modified glassy carbon electrode for electrochemical simultaneous detection of hydroquinone and catechol. Ecotoxicol. Environ. Saf. 2019;184:109619. doi: 10.1016/j.ecoenv.2019.109619. [DOI] [PubMed] [Google Scholar]
  • 7.Zheng X, Hu Y, Li H, Han B, Lin R, Huang B. N-doped carbon nanotube frameworks modified electrode for the selective sensing of hydroquinone and catechol. J. Electroanal. Chem. 2020;861:113968. doi: 10.1016/j.jelechem.2020.113968. [DOI] [Google Scholar]
  • 8.Song Y, Zhang Y, Li J, Tan C, Li Y. Preparation of poly ionic liquid-mesoporous carbon nanospheres and its application in simultaneous determination of hydroquinone and catechol, and detection of paracetamol. J. Electroanal. Chem. 2020;865:114157. doi: 10.1016/j.jelechem.2020.114157. [DOI] [Google Scholar]
  • 9.Yin D, Liu J, Bo X, Guo L. Cobalt-iron selenides embedded in porous carbon nanofibers for simultaneous electrochemical detection of trace of hydroquinone, catechol and resorcinol. Anal. Chim. Acta. 2020;1093:35–42. doi: 10.1016/j.aca.2019.09.057. [DOI] [PubMed] [Google Scholar]
  • 10.Li C, Liu W, Gu Y, Hao S, Yan X, Zhang Z, Yang M. Simultaneous determination of catechol and hydroquinone based on poly (sulfosalicylic acid)/functionalized graphene modified electrode. J. Appl. Electrochem. 2014;44:1059–1067. doi: 10.1007/s10800-014-0713-z. [DOI] [Google Scholar]
  • 11.Ahammad AJS, Sarker S, Rahman MA, Lee JJ. Simultaneous determination of hydroquinone and catechol at an activated glassy carbon electrode. Electroanalysis. 2010;22:694–700. doi: 10.1002/elan.200900449. [DOI] [Google Scholar]
  • 12.Yuan X, Wang B, Yana C, Lv W, Ma Q, Zheng B, Du J, Xiao D. A rapid and simple strategy for discrimination and detection of catechol and hydroquinone by fluorescent silicon nanoparticles. Microchemical J. 2020;158:105263. doi: 10.1016/j.microc.2020.105263. [DOI] [Google Scholar]
  • 13.Chetankumar K, Swamy BEK, Sharma SC. Fabrication of voltammetric efficient sensor for catechol, hydroquinone and resorcinol at MgO modified pre-treated carbon paste electrode. Mater. Chem. Phys. 2020;252:123231. doi: 10.1016/j.matchemphys.2020.123231. [DOI] [Google Scholar]
  • 14.Chen H, Wu X, Lao C, Li Y, Yuan Q, Gan W. MOF derived porous carbon modified rGO for simultaneous determination of hydroquinone and catechol. J. Electroanal. Chem. 2019;835:254–261. doi: 10.1016/j.jelechem.2019.01.027. [DOI] [Google Scholar]
  • 15.Huang L, Cao Y, Diao D. Electrochemical activation of graphene sheets embedded carbon films for high sensitivity simultaneous determination of hydroquinone, catechol and resorcinol. Sens. Actuator B Chem. 2020;305:127495. doi: 10.1016/j.snb.2019.127495. [DOI] [Google Scholar]
  • 16.Zhu Y, Huai S, Jiao J, Xu Q, Wu H, Zhang H. Fullerene and platinum composite-based electrochemical sensor for the selective determination of catechol and hydroquinone. J. Electroanal. Chem. 2020;878:114726. doi: 10.1016/j.jelechem.2020.114726. [DOI] [Google Scholar]
  • 17.Pistonesi MF, Di Nezio MS, Centurion ME, Palomeque ME, Lista AG, Fernandez Band BS. Determination of phenol, resorcinol and hydroquinone in air samples by synchronous fluorescence using partial least-squares (PLS) Talanta. 2006;69:1265–1268. doi: 10.1016/j.talanta.2005.12.050. [DOI] [PubMed] [Google Scholar]
  • 18.Dong S, Chi L, Yang Z, He P, Wang Q, Fang Y. Simultaneous determination of dihydroxybenzene and phenylenediamine positional isomers using capillary zone electrophoresis coupled with amperometric detection. J. Sep. Sci. 2009;32:3232–3238. doi: 10.1002/jssc.200900120. [DOI] [PubMed] [Google Scholar]
  • 19.Ramakrishnan P, Rangiah K. A UHPLC-MS/SRM method for analysis of phenolics from Camellia sinensis leaves from Nilgiri hills. Anal. Methods. 2016;8:8033–8041. doi: 10.1039/C6AY02329K. [DOI] [Google Scholar]
  • 20.Moldoveanu SC, Kiser M. Gas chromatography/mass spectrometry versus liquid chromatography/fluorescence detection in the analysis of phenols in mainstream cigarette smoke. J. Chromatogr. A. 2007;1141:90–97. doi: 10.1016/j.chroma.2006.11.100. [DOI] [PubMed] [Google Scholar]
  • 21.Liu Y, Wang YM, Zhu WY, Zhang CH, Tang H, Jiang JH. Conjugated polymer nanoparticles-based fluorescent biosensor for ultrasensitive detection of hydroquinone. Anal. Chim. Acta. 2018;1012:60–65. doi: 10.1016/j.aca.2018.01.027. [DOI] [PubMed] [Google Scholar]
  • 22.Fan SL, Zhang LK, Lin JM. Post-column detection of benzenediols and 1,2,4-benzenetriol based on acidic potassium permanganate chemiluminescence. Talanta. 2006;68:646–652. doi: 10.1016/j.talanta.2005.05.004. [DOI] [PubMed] [Google Scholar]
  • 23.Sarvajith MS, Mruthyunjayachari CD, Harish MNK, Khan F. Phthalocyanine pendented polyaniline via amide linkage for an electrochemical sensing of H2O2. Microchemical J. 2021;161:105781. doi: 10.1016/j.microc.2020.105781. [DOI] [Google Scholar]
  • 24.Gupta VK, Mergu N, Kumawat LK, Singh AK. Selective naked-eye detection of Magnesium(II) ions using a coumarin-derived fluorescent probe. Sens. Actuator B Chem. 2015;207:216–223. doi: 10.1016/j.snb.2014.10.044. [DOI] [Google Scholar]
  • 25.Chetankumar K, Swamy BEK, Sharma SC. Electrochemical preparation of poly (direct yellow 11) modified pencil graphite electrode sensor for catechol and hydroquinone in presence of resorcinol: A voltammetric study. Microchemical J. 2020;156:104979. doi: 10.1016/j.microc.2020.104979. [DOI] [Google Scholar]
  • 26.Gupta VK, Jain AK, Khayat MA, Bhargava SK, Raisoni JR. Electroanalytical studies on cobalt(II) selective potentiometric sensor based on bridge modified calixarene in poly(vinyl chloride) Electrochim. Acta. 2008;53:5409–5414. doi: 10.1016/j.electacta.2008.02.085. [DOI] [Google Scholar]
  • 27.Karimi-Maleha H, Yola ML, Atar N, Orooji Y, Karimi F, Kumar PS, Rouhi J, Baghayeri M. A novel detection method for organophosphorus insecticide fenamiphos: Molecularly imprinted electrochemical sensor based on core-shell Co3O4@MOF-74 nanocomposite. J. Colloid Interface Sci. 2021;592:174–185. doi: 10.1016/j.jcis.2021.02.066. [DOI] [PubMed] [Google Scholar]
  • 28.Karimi-Maleh H, Alizadeh M, Orooji Y, Karimi F, Baghayeri M, Rouhi J, Tajik S, Beitollahi H, Agarwal S, Gupta VK, Rajendran S, Rostamnia S, Fu L, Saberi-Movahed F, Malekmohammadi S. Guanine-based DNA biosensor amplified with Pt/SWCNTs Nanocomposite as analytical tool for nanomolar determination of daunorubicin as an anticancer drug: A docking/experimental investigation. Ind. Eng. Chem. Res. 2021;60:816–823. doi: 10.1021/acs.iecr.0c04698. [DOI] [Google Scholar]
  • 29.Chetankumar K, Swamy BEK, Naik HSB. MgO and MWCNTs amplified electrochemical sensor for guanine, adenine and epinephrine. Mater. Chem. Phys. 2021;267:124610. doi: 10.1016/j.matchemphys.2021.124610. [DOI] [Google Scholar]
  • 30.Karimi-Maleh H, Cellat K, Arikan K, Savk A, Karimi F, Sen F. Palladium-nickel nanoparticles decorated on functionalized-MWCNT for high precision non-enzymatic glucose sensing. Mater. Chem. Phys. 2020;250:123042. [Google Scholar]
  • 31.He S, Chen Z, Yu Y, Shi L. A novel non enzymatic hydrogen peroxide sensor based on poly-melamine film modified with platinum nanoparticles. RSC Adv. 2014;4:45185–45190. doi: 10.1039/C4RA06925K. [DOI] [Google Scholar]
  • 32.Chetankumar K, Swamy BEK. Electrochemical investigation of catechol and hydroquinone at poly(o-phenylenediamine) modified carbon paste electrode: A voltammetric study. Anal. Bioanal. Electrochem. 2019;11:1638–1650. [Google Scholar]
  • 33.Kumar N, Goyal RN. Simultaneous determination of melatonin and 5-hydroxytrptophan at the disposable poly-(melamine)/poly-(o-aminophenol) composite modified screen printed sensor. J. Electroanal. Chem. 2020;874:114458. doi: 10.1016/j.jelechem.2020.114458. [DOI] [Google Scholar]
  • 34.Naik TSSK, Swamy BEK, Ramamurthy PC, Chetankumar K. Poly (L-leucine) modified carbon paste electrode as an electrochemical sensor for the detection of paracetamol in presence of folic acid. Mater. Sci. Energy Technol. 2020;3:626–632. [Google Scholar]
  • 35.Harja M, Kotova O, Samuil C, Ciocinta R, Ciobanu G. Adsorption of direct green 6 dye onto modified power plant ash. Lucrari Stiintifice Ser. Agron. 2017;60:15–20. [Google Scholar]
  • 36.Shilpa G, Yogendra K, Mahadevan KM, Madhusudhana N, Santhosh AM. A comparative study over degradation of direct green 6 by using synthesized magnesium aluminate and magnesium zincate nanoparticles. IOSR J. Appl. Chem. 2018;11:01–08. [Google Scholar]
  • 37.Teradale AB, Lamani SD, Ganesh PS, Swamy BEK, Das SN. Poly-nile blue based electrochemical sensor for catechol and hydroquinone. Anal. Bioanal. Electrochem. 2019;11:1176–1190. [Google Scholar]
  • 38.Chetankumar K, Swamy BEK, Sharma SC. Poly (benzoguanamine) modified sensor for catechol in presence of hydroquinone: A voltammetric study. J. Electroanal. Chem. 2019;849:113365. doi: 10.1016/j.jelechem.2019.113365. [DOI] [Google Scholar]
  • 39.Kuskur CM, Swamy BEK, Jayadevappa H, Ganesh PS. Ploy (rhodamine B) sensor for the norepinephrine and paracetamol: A voltammetric study. Ionics. 2018;24:3631–3640. doi: 10.1007/s11581-018-2483-9. [DOI] [Google Scholar]
  • 40.Pandey A, Sharma S, Jain R, Raja AN. Review-pencil graphite electrode: An emerging sensing material. J. Electrochem. Soc. 2020;167:037501. doi: 10.1149/2.0012003JES. [DOI] [Google Scholar]
  • 41.Tekenya R, Pokpas K, Jahed N, Iwuoha EI. Enhanced specificity and sensitivity for the determination of nickel(II) by square-wave adsorptive cathodic stripping voltammetry at disposable graphene-modified pencil graphite electrodes. Anal. Lett. 2019;52:373–398. doi: 10.1080/00032719.2018.1469139. [DOI] [Google Scholar]
  • 42.Dang Y, Wang X, Cui R, Chen S, Zhou Y. A novel electrochemical sensor for the selective determination of hydroquinone and catechol using synergic effect of electropolymerized nicotinic acid film and Cd-doped ZnWO4 nanoneedle. J. Electroanal. Chem. 2019;834:196–205. doi: 10.1016/j.jelechem.2018.12.059. [DOI] [Google Scholar]
  • 43.Zhao L, Yu J, Yue S, Zhang L, Wang Z, Guo P, Liu Q. Nickel oxide/carbon nanotube nanocomposites prepared by atomic layer deposition for electrochemical sensing of hydroquinone and catechol. J. Electroanal. Chem. 2018;808:245–251. doi: 10.1016/j.jelechem.2017.12.019. [DOI] [Google Scholar]
  • 44.Fan L, Li X, Kan X. Disposable graphite paper based sensor for sensitive simultaneous determination of hydroquinone and catechol. Electrochim. Acta. 2016;213:504–511. doi: 10.1016/j.electacta.2016.06.096. [DOI] [Google Scholar]
  • 45.Jiang D, Pang J, You Q, Liu T, Chu Z, Jin W. Simultaneous biosensing of catechol and hydroquinone via a truncated cube-shaped Au/PBA nanocomposite. Biosens. Bioelectron. 2019;124–125:260–267. doi: 10.1016/j.bios.2018.09.094. [DOI] [PubMed] [Google Scholar]
  • 46.Wang Z, Li M, Ye Y, Yang Y, Lu Y, Ma X, Zhang Z, Xiang S. MOF-derived binary mixed carbon/metal oxide porous materials for constructing simultaneous determination of hydroquinone and catechol sensor. J. Solid State Electrochem. 2019;23:81–89. doi: 10.1007/s10008-018-4111-z. [DOI] [Google Scholar]
  • 47.Chetankumar K, Swamy BEK, Naik TSSK. A reliable electrochemical sensor for detection of catechol and hydroquinone at MgO/GO modified carbon paste electrode. J. Mater. Sci. Mater. Electron. 2020;31:19728–19740. doi: 10.1007/s10854-020-04498-x. [DOI] [Google Scholar]
  • 48.Charithra MM, Manjunatha JG. Poly (l-Proline) modified carbon paste electrode as the voltammetric sensor for the detection of Estriol and its simultaneous determination with Folic and Ascorbic acid. Mater. Sci. Energy Technol. 2019;2:365–371. [Google Scholar]
  • 49.Fan J, Pang J, Zhang Y, Zhang L, Xua W, Wang J. Simultaneous detection of hydroquinone and catechol with decreasing pH at a bare glassy carbon electrode surface. Anal. Methods. 2019;11:604–609. doi: 10.1039/C8AY02419G. [DOI] [Google Scholar]
  • 50.Zhang J, Song X, Ma S, Wang X, Wang W, Chen Z. A novel sodium dodecyl benzene sulfonate modified expanded graphite paste electrode for sensitive and selective determination of dopamine in the presence of ascorbic acid and uric acid. J. Electroanal. Chem. 2017;795:10–16. doi: 10.1016/j.jelechem.2017.04.035. [DOI] [Google Scholar]
  • 51.Liu J, Bao H, Liu C, Wu F, Fu T. “Turn-on” fluorometric probe for hydroquinone and catechol based on an in situ reaction between protamine sulfate and dihydroxybenzene isomers and the formation of fluorescent polymer nanoparticles. Sens. Actuator B Chem. 2021;333:129565. doi: 10.1016/j.snb.2021.129565. [DOI] [Google Scholar]
  • 52.Hong-Ying L, Lang-Lang Z, Zhi-Heng H, Yu-Bing Q, Han-Xiao X, Jia-Jun W, Wei-Wei X, Li-Hua L, Chun-Chuan G. Simultaneous detection of hydroquinone, catechol and resorcinol by an electrochemical sensor based on ammoniated-phosphate buffer solution activated glassy carbon electrode. Chinese J. Anal. Chem. 2019;47:19113–19120. doi: 10.1016/S1872-2040(19)61183-7. [DOI] [Google Scholar]
  • 53.Qi Y, Cao Y, Meng X, Cao J, Li X, Hao Q, Lei W, Li Q, Li J, Si W. Facile synthesis of 3D sulfur/nitrogen co-doped graphene derived from graphene oxide hydrogel and the simultaneous determination of hydroquinone and catechol. Sens. Actuator B Chem. 2019;279:170–176. doi: 10.1016/j.snb.2018.09.067. [DOI] [Google Scholar]
  • 54.Patil SK, Patil SA, Vadiyar MM, Awale DV, Sartape AS, Walekar LS, Kolekar GB, Ghorpade UV, Kim JH, Kolekar SS. Tailor-made dicationic ionic liquid as a fluorescent sensor for detection of hydroquinone and catechol. J. Mol. Liq. 2017;244:39–45. doi: 10.1016/j.molliq.2017.08.119. [DOI] [Google Scholar]
  • 55.Song Y, Zhao M, Wang X, Qu H, Liu Y, Chen S. Simultaneous electrochemical determination of catechol and hydroquinone in seawater using Co3O4/MWCNTs/GCE. Mater. Chem. Phys. 2019;234:217–223. doi: 10.1016/j.matchemphys.2019.05.071. [DOI] [Google Scholar]
  • 56.Nagarajan S, Vairamuthu R, Angamuthu R, Venkatachalam G. Electrochemical fabrication of reusable pencil graphite electrodes for highly sensitive, selective and simultaneous determination of hydroquinone and catechol. J. Electroanal. Chem. 2019;846:113156. doi: 10.1016/j.jelechem.2019.05.038. [DOI] [Google Scholar]
  • 57.Babua RS, Prabhua P, Narayanan SS. Selective and sensitive determination of dihydroxybenzene isomers in water samples using functionalized copper nanoparticles modified graphite electrode. Mater. Today Proc. 2021;36:867–872. doi: 10.1016/j.matpr.2020.07.020. [DOI] [Google Scholar]
  • 58.Dongmo LM, Jiokenga SLZ, Pecheu CN, Walcarius A, Tonle IK. Amino-grafting of montmorillonite improved by acid activation and application to the electroanalysis of catechol. Appl. Clay Sci. 2020;191:105602. doi: 10.1016/j.clay.2020.105602. [DOI] [Google Scholar]
  • 59.Chetankumar K, Swamy BEK, Naik TSSK. Electrochemical sensing of catechol in presence of hydroquinone using a carbon paste electrode amplified with poly (vanillin) Chem. Data Collect. 2020;28:100392. doi: 10.1016/j.cdc.2020.100392. [DOI] [Google Scholar]
  • 60.Zhang Y, Xie Q, Xia Z, Gui G, Deng F. Graphdiyne oxides as new modifier for the simultaneous electrochemical detection of phenolic compounds. J. Electroanal. Chem. 2020;863:114058. doi: 10.1016/j.jelechem.2020.114058. [DOI] [Google Scholar]

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES