Serge Kobsa a, Nicholas J Morrissey b, Hiroo Takayama a,c,d,
PMCID: PMC8304487  PMID: 34317880

graphic file with name fx1.jpg

Hiroo Takayama, MD, PhD, Nicholas J. Morrissey, MD, and Serge Kobsa, MD, PhD

Central Message.

An arteriovenous fistula presents a viable permanent dialysis access in a patient with a total artificial heart.

See Article page 220.

It is estimated that more than 6 million Americans are living with heart failure (HF) and projected that this number will increase 46% from 2012 to 2030, resulting in >8 million people with HF in the United States.1 Approximately 25,000 patients between 2006 and 20182 have been supported by implanted mechanical circulatory devices, and one half of all heart transplant recipients are being bridged using mechanical circulatory support.3 Notably, a significant number of these patients are hemodialysis dependent.4 The high incidence of renal dysfunction in patients with end-stage HF is unsurprising, given that many of them have significant environmental and genetic cardiovascular risk factors and multiple comorbidities.5 In addition, they experience chronically inadequate renal perfusion secondary to long-standing HF, as well as being at risk for acute-on-chronic kidney injury during episodes of decompensated HF, or during periods of hemodynamic instability related to MCS device implantation or other cardiac procedures.

Strategies for addressing vascular access in patients with continuous-flow left ventricular assist devices have been well described.6,7 Because of theoretical concerns regarding arteriovenous (AV) fistula venous maturation in the absence of pulsatile flow,6,7 we and many other experts opt to use AV grafts in patients with continuous-flow left ventricular assist devices.8 The authors pursued the creation of a staged brachiobasilic arteriovenous fistula in a patient supported with a total artificial heart (TAH).9 This approach appears plausible for a number of reasons. The Syncardia TAH (SynCardia Systems, Inc, Tucson, Ariz), the only TAH approved by the Food and Drug Administration in the United States,10 is a pneumatically driven pulsatile flow device, which mitigated the concern for lack of AVF maturation. Use of a native vein may reduce another concern in patients with an implanted MCS device, which is infection and hematogenous seeding of the implant. This risk is augmented by repeated vascular access necessary for hemodialysis, and particularly exacerbated by the presence of an indwelling tunneled dialysis catheter. The use of a dialysis catheter with TAH requires extra caution due to the presence of a mechanical tricuspid valve as well. Furthermore, an AV graft might increase the risk of local infection after a heart (and kidney) transplant.

The authors acknowledge uncertainty regarding the potential for TAH-driven super-physiologic pulsatile flow affecting fistula arterialization and wall integrity but report that the AVF did adequately mature, with sufficient size, arterialization, wall thickening, and high flow rates, despite requiring 3 interventions for atypical aneurysmal degeneration of the arterial limb of the fistula during the 15 months of use, before the patient received a heart–kidney transplant. With more experience, the procedure may be performed in a single setting, saving the patient a second operation.

Like in most cases of advances borne out of necessity, Hair and colleagues used their judgment and experience and applied sound surgical principles to a novel clinical scenario while dealing with uncertainty. Despite complications, their team managed to successfully bridge a patient to a double-organ transplant and demonstrate that, especially as medical devices and technology become ever more complex and ubiquitous, surgeons will continue to innovate.

Footnotes

Disclosures: The authors reported no conflicts of interest.

The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest.

References

  • 1.Virani S.S., Alonso A., Benjamin E.J., Bittencourt M.S., Callaway C.W., Carson A.P. Heart disease and stroke statistics—2020 update: a report from the American Heart Association. Circulation. 2020;141:e139–e596. doi: 10.1161/CIR.0000000000000757. [DOI] [PubMed] [Google Scholar]
  • 2.Teuteberg J.J., Cleveland J.C., Cowger J., Higgins R.S., Goldstein D.J., Keebler M. The Society of Thoracic Surgeons intermacs 2019 annual report: the changing landscape of devices and indications. Ann Thorac Surg. 2020;109:649–660. doi: 10.1016/j.athoracsur.2019.12.005. [DOI] [PubMed] [Google Scholar]
  • 3.Khush K.K., Cherikh W.S., Chambers D.C., Harhay M.O., Hayes D., Jr., Hsich E. The international thoracic organ transplant registry of the International Society for Heart and Lung Transplantation: thirty-sixth adult heart transplantation report—2019; focus theme: donor and recipient size match. J Heart Lung Transplant. 2019;38:1056–1066. doi: 10.1016/j.healun.2019.08.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Kamboj M., Kazory A. Left ventricular assist device and the kidney: getting to the heart of the matter. Blood Purif. 2019;48:289–298. doi: 10.1159/000502080. [DOI] [PubMed] [Google Scholar]
  • 5.Ross D.W., Stevens G.R., Wanchoo R., Majure D.T., Jauhar S., Fernandez H.A. Left ventricular assist devices and the kidney. Clin J Am Soc Nephrol. 2018;13:348–355. doi: 10.2215/CJN.04670417. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Amir O., Radovancevic B., Delgado R.M., Kar B., Radovancevic R., Henderson M. Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support. J Heart Lung Transplant. 2006;25:391–394. doi: 10.1016/j.healun.2005.11.439. [DOI] [PubMed] [Google Scholar]
  • 7.Patel A.M., Adeseun G.A., Ahmed I., Mitter N., Rame J.E., Rudnick M.R. Renal failure in patients with left ventricular assist devices. Clin J Am Soc Nephrol. 2013;8:484–496. doi: 10.2215/CJN.06210612. [DOI] [PubMed] [Google Scholar]
  • 8.Allon M., Lok C.E. Dialysis fistula or graft: the role for randomized clinical trials. Clin J Am Soc Nephrol. 2010;5:2348–2354. doi: 10.2215/CJN.06050710. [DOI] [PubMed] [Google Scholar]
  • 9.Hair B.B., Kirksey L., Tong M.Z., Soltesz E., Hanna M. Permanent dialysis access in a patient with a total artificial heart. J Thorac Cardiovasc Surg Tech. 2020;3:220–222. doi: 10.1016/j.xjtc.2020.06.047. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Melton N., Soleimani B., Dowling R. Current role of the total artificial heart in the management of advanced heart failure. Curr Cardiol Rep. 2019;21:142. doi: 10.1007/s11886-019-1242-5. [DOI] [PubMed] [Google Scholar]

Articles from JTCVS Techniques are provided here courtesy of Elsevier

RESOURCES