Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2021 Jul 28.
Published in final edited form as: Phys Rev C. 2017 Jul 18;96(1):014613. doi: 10.1103/physrevc.96.014613

Half-life of 51Mn

Stephen A Graves 1, Paul A Ellison 1, Hector F Valdovinos 1, Todd E Barnhart 1, Robert J Nickles 1,*, Jonathan W Engle 1,
PMCID: PMC8317495  NIHMSID: NIHMS1665431  PMID: 34327291

Abstract

The half-life of 51Mn was measured by serial gamma spectrometry of the 511-keV annihilation photon following decay by β+ emission. Data were collected every 100 seconds for 100,000–230,000 seconds within each measurement (n = 4). The 511-keV incidence rate was calculated from the 511-keV spectral peak area and count duration, corrected for detector dead time and radioactive decay. Least-squares regression analysis was used to determine the half-life of 51Mn while accounting for the presence of background contaminants, notably 55Co. The result was 45.59 ± 0.07 min, which is the highest precision measurement to date and disagrees with the current Nuclear Data Sheets value by over 6σ.

I. INTRODUCTION

Positron-emitting isotopes of manganese have shown promise for a variety of medical applications in recent years [17]. Accurate and precise measurements of radioactive half-life are essential for quantitative biomedical studies.

During experimentation with 51Mn, we observed that the half-life was shorter than the specified value of 46.2 ± 0.1 min from the most recent A = 51 Nuclear Data Sheets evaluation [8]. Previous 51Mn half-life measurements [914] are summarized in Table I. In light of the observed discrepancy from these values, we design a dedicated experiment to measure the half-life of 51Mn.

TABLE I.

Previous measurements of the radioactive half-life of 51Mn, including the result from this work.

Reference t1/2 ± σ (min)
Livingood, 1938 [9] 46 ± 2
Miller, 1948 [10] 45
Burgus, 1950 [11] 44.3 ± 0.5
Gilbert, 1966 [12] 46.5 ± 0.2
Erlandsson, 1969 [13] 46.2 ± 0.1
Ferrer, 1973 [14] [46.2 ± 0.1]a
This work 45.59 ± 0.07
a

Authors state that their measurement is “in agreement with” Erlandsson et al.

II. METHODS

51Mn was produced by 16-MeV proton irradiation (GE PETtrace) of isotopically enriched 54Fe (30–60 mg, 99.93% enriched, Isoflex USA), which had been electrodeposited over an area of ~1 cm2 on 0.5-mm thick, 21-mm diameter Ag discs. 51Mn was radiochemically isolated from the target material by dissolution of the 54Fe material followed by anion exchange chromatography as previously described [5]. An aliquot of 51Mn (1–2 MBq in 20–100 μl) was then prepared for spectroscopic measurements.

A high-purity germanium (HPGe, Canberra C1519) gamma detector was calibrated for efficiency and energy response using point sources of 241Am, 133Ba, 137Cs, and 60Co, obtained from the National Institute of Standards and Technology (NIST, Gaithersburg, MD, USA) and an in-house quantified point source of 152Eu. Consecutive gamma spectra were for acquired with a 51Mn sample in an unperturbed geometry for 25–60 hours. Acquisition lengths were set to 100 seconds live-time, resulting in 1000–2200 spectral time-points per measurement (n = 4). 51Mn was produced prior to each measurement with a complete irradiation and radiochemical separation. Only one aliquot of 51Mn from each production was used for a measurement. Due to the low branching ratio of the primary gamma emission of 51Mn (749.07 keV, 0.265%), the 511-keV annihilation photon was utilized for half-life determination. Peak area was calculated by subtraction of an average background continuum determined from bins above and below the peak energy. The sensitivity of the measured half-life to changes in the count durations was evaluated by retrospectively rebinning spectral data into 500-s count durations.

Early spectral acquisitions were associated with up to 7% detector dead-time, resulting in ~107 s elapsing (Treal) for a 100 s live-time (Tlive) acquisition. To correct for radioactive decay during each acquisition, the initial 511-keV “incidence rate” (I0) was obtained. If it is assumed that dead-time does not change significantly during a single acquisition and that the nominal decay constant (λ) is sufficiently close to the true value, then the relationship between the number of counts in the 511-keV peak in a spectra (N) and I0 is described by Eq. (1)

N=0Treal Tlive Treal I0eλtdt. (1)

Evaluating this integral we obtain

I0=(NTlive )(λTreal 1eλTreal ). (2)

It is also useful to make the following definition:

C(λTreal 1eλTreal ). (3)

With this notation, C may be thought of as a correction factor for dead-time and radioactive decay. For early time-points where dead-time was greater than 5%, this correction was 1.0133. For intermediate time-points where dead-time was less than 1% (511-keV peak area still 51Mn-dominated), this corrective factor was reduced to 1.0126. At late time-points where 51Mn had decayed below background levels, the decay constant for 55Co was employed for this correction. During these late time-points, this correction was found to be less than 1.0006.

Radioactive contaminants were identified by summing the acquired spectra and identifying characteristic gamma emissions. Contaminants with direct contribution to the 511-keV peak included 55Co, 56Co, 208Tl, and 106Ag. Contaminants with indirect contribution to the 511-keV peak through pair production included 65Zn, 214Bi, 60Co, 22Na, 40K, and 88Y. Given that the half-lives of these contaminants are significantly greater than that of 51Mn, the majority are well approximated by linear or constant background fitting components to the 511-keV incidence rate decay curve. 55Co, likely produced from the (p,2n) reaction on 56Fe impurities in the target material, was treated independently in decay fitting due to its shorter half-life and relatively high abundance.

Decay curve least-squares fitting was performed using the model described by Eq. (2), where A1, λ1, A2, λ2, M, and C were fitting parameters. To specifically account for the presence of 55Co, λ2 was constrained to ln(2)/(63108 s). The sensitivity of this constraint to the uncertainty in the nominal 55Co half-life was evaluated. Fitting was performed over the full set of data for each run, without temporal truncation

f(t)=A1eλ1t+A2eλ2t+Mt+C. (4)

Initial least-squares fitting was weighted by the square-root of the measured 511-keV count rate divided by the square root of the count duration. After this first-pass of curve fitting, fitting was performed weighted by a floating standard deviation of the first-pass fitting residuals. The width of this variance estimation window was nominally chosen to be 3000 s, centered at the sample of interest. It is not obvious that this window should be sample-centered, however, application of the mean value theorem over 3000 s to an approximation of the uncertainty function (square root of count rate) reveals that this is appropriate. Fitting was performed iteratively using this weighting method until changes in the obtained fitting parameters were negligible.

To ensure that data were not affected by drift in the digital acquisition clock, the CPU clock was compared against the web-based NIST clock. We observed a maximum drift of −7.6 ± 0.3 s in the CPU clock compared to the web-based NIST clock during a 68-h acquisition. This deviation results in a correction to the measured 51Mn half-life of less than 0.002 min, which is herein considered negligible.

All measurement and statistical uncertainty was assumed to be normally distributed for propagation calculations. All uncertainties in this work are presented as ± one standard deviation (σ).

III. RESULTS AND DISCUSSION

An example gamma spectrum is shown in Fig. 1 and a representative decay curve and corresponding fit are shown in Fig. 2. A final 51Mn radioactive half-life value for 51Mn of 45.59 ± 0.07 min was obtained. The final result is compared against literature values in Table I and the results from individual measurements are listed in Table II.

FIG. 1.

FIG. 1.

Example HPGe gamma spectrum of 51Mn with 3600-s. count duration.

FIG. 2.

FIG. 2.

Decay curve fitting for one representative measurement and associated fitting residuals. Serial spectroscopic measurements were acquired over approximately 230,000 s and the 511-keV peak fit by a two-component exponential and linear component decay curve. The right plot shows a subset of the full data set, over one decade of 51Mn decay, indicated by the rectangle in the left plot.

TABLE II.

51Mn half-life measurements in this work.

Measurement t1/2 ± σ (s) χ2/dof
1 45.63 ± 0.06 1.004
2 45.56 ± 0.04 0.995
3 45.53 ± 0.04 1.001
4 45.66 ± 0.04 0.992
Average 45.59±0.07

This obtained half-life value does not agree with the most precise previous measurement, made by Erlandsson et al. in 1969 [13], of 46.2 ± 0.1 min, which is also the currently accepted value. In their work, Erlandsson et al. produced radioisotopically pure 51Mn by 50Cr(p,γ), and performed serial annihilation photon spectroscopic measurements—NaI(Tl) detector, 400–600 keV window—over approximately 6600 s. A single-component exponential model was used for decay fitting, which ignored contributions from background contaminants, such as the annihilation photons following pair production from the 1461 keV 40K γ emission.

Without considering other possible confounding factors, a plausible explanation for the shorter half-life result obtained herein is the presence of 52mMn in our radioactivity samples, however the 1434 keV characteristic 52mMn γ emission was not observed.

To investigate this discrepancy, a truncated set of our data was created (0–20,000 s) and was fit to a single-component exponential model. The half-life result from this fitting (46.13 ± 0.04 min) is in excellent agreement with the literature value of 46.2 ± 0.1 min. However, if we fit this truncated data set to the full model described by Eq. (2) constraining A2, λ2, M, and C to values obtained from fitting the full data set, a 51Mn half-life value of 45.70 ± 0.04 min is obtained, which is in agreement with the value reported here. This constrained fit on data from t = 0–20,000 s also qualitatively improved the “goodness of fit” in the latter portion of the truncated data set compared to the unconstrained fit.

The robustness of radioisotopic impurity quantification in our regression model was examined. The most significant impurity, 55Co, was quantified by fitting the decay of its characteristic 931 keV gamma over the collected serial spectra. 55Co radioactivity at t = 0 was quantified by correcting for branching ratio and detector efficiency. This secondary quantification was in excellent agreement with the 55Co radioactivity quantification obtained from the A2 fitting parameter in 511 keV fitting, 12.8 ± 1.1 and 12.3 ± 0.8 kBq, respectively. This suggests that explicit fitting of 55Co in the 511-keV regression model is appropriate and robust.

51Mn half-life measurements did not depend strongly on the constrained half-life of 55Co in decay curve fitting. Perturbing the constrained half-life of 55Co (nominally 17.53 ± 0.03 h) for one measurement dataset by 10% to 15.77 h or 19.28 h results in a change to the measured 51Mn half-life of less than 0.0002%. Furthermore, 51Mn half-life measurements were not sensitive to changes in count duration. Retrospectively rebinning the acquired spectra into 500-s-count durations resulted in no significant change to the measured half-life values.

An attempt was also made to quantify the half-life of 51Mn using the 749.1-keV peak from the spectral data of one measurement. Data were rebinned into 1000 s acquisitions to improve statistics, and regression analysis was performed using a single exponential and background component; f (t) = Aeλt + C. The result from this measurement was 50 ± 7 min, the which suggests that a precise half-life evaluation using 749.1 keV peak in our data is unfeasible.

The discrepancy between the measured half-life value in this work (45.59 min) and the literature value (46.2 min) is a difference of approximately 1.3%. A difference of this degree could conceivably impact the results of preclinical biomedical studies through systematic error in decay correction. For example, it is common to administer radioactivity to animal subjects several hours before tissue uptake is quantified. Assuming 4 h of radioactive decay during this window, the discrepancy described herein results in a ~ 5% systematic error in tissue uptake quantification. An error of this magnitude is not insignificant when compared with other sources of uncertainty in studies of this design. For this reason, we believe this work will serve to improve the accuracy of preclinical biomedical studies employing 51Mn.

IV. CONCLUSION

The half-life of 51Mn has been measured to be 45.59 ± 0.07 min. This is the most precise measurement to date, and disagrees with the Nuclear Data Sheets (NDS) value by over 6σ. Due to the improved fitting model and data acquisition duration in this work, we believe that this measurement is more accurate than previous literature values.

ACKNOWLEDGMENTS

This work was funded, in part, by the National Institutes of Health (T32-CA009206).

References

  • [1].Topping GJ, Schaffer P, Hoehr C, Ruth TJ, and Sossi V, Med. Phys 40, 042502 (2013). [DOI] [PubMed] [Google Scholar]
  • [2].Lewis CM, Graves SA, Hernandez R, Valdovinos HF, Barnhart TE, Cai W, Meyerand ME, Nickles RJ, and Suzuki M, Theranostics 5, 227 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [3].Graves SA, Hernandez R, Fonslet J, England CG, Valdovinos HF, Ellison PA, Barnhart TE, Elma DR, Theuer CP, Cai W, Nickles RJ, and Severin GW, Bioconjugate Chem. 26, 2118 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [4].Fonslet J, Tietze S, Jensen AI, Graves SA, and Severin GW, Appl. Radiat. Isot 121, 38 (2017). [DOI] [PubMed] [Google Scholar]
  • [5].Graves SA, Hernandez R, Valdovinos HF, Ellison PA, Engle JW, Barnhart TE, and Nickles RJ, Sci. Rep 7, 3033 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [6].Hernandez R, Graves SA, Gregg T, England CG, Valdovinos HF, Jeffery JJ, Barnhart TE, Severin GW, Nickles RJ, Merrins MJ, and Cai W, Radiomanganese PET detects changes in β-cell mass in mouse models of diabetes, Diabetes (2017), doi: 10.2337/db16-1285. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [7].Wooten AL, Aweda TA, Lewis BC, Gross RB, and Lapi SE, PloS One 12, e0174351 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [8].Xiaolong H, Nucl. Data Sheets 107, 2131 (2006). [Google Scholar]
  • [9].Livingood JJ and Seaborg GT, Phys. Rev 54, 391 (1938). [Google Scholar]
  • [10].Miller DR, Thompson RC, and Cunningham BB, Phys. Rev 74, 347 (1948). [Google Scholar]
  • [11].Burgus WH and Kennedy JW, J. Chem. Phys 18, 97 (1950). [Google Scholar]
  • [12].Gilbert KM and Easterday HT, Nucl. Phys 86, 279 (1966). [Google Scholar]
  • [13].Erlandsson B, Marcinkowski A, and Wall N, Ark. Fys 40, 139 (1969). [Google Scholar]
  • [14].Ferrer JC and Rapaport J, Z. Phys 265, 365 (1973). [Google Scholar]

RESOURCES