Target coverage of daily cone-beam computed tomography in breath-hold image-guided radiotherapy for gastric lymphoma

Shigeo Takahashi 1,, Takamasa Nishide 1, Masato Tsuzuki 2, Hiroki Katayama 2, Masahide Anada 1, Toshifumi Kinoshita 1, Shohei Kozai 1, Toru Shibata 1
PMCID: PMC8320113  PMID: 34381938

Abstract

Objectives:

We evaluated retrospectively the daily target coverage using cone-beam computed tomography (CBCT) in breath-hold image-guided radiotherapy (BH-IGRT) for gastric lymphoma.

Methods:

BH-IGRT was performed using a prescribed dose of 30.6 Gy in 17 fractions for the whole stomach. We assessed the target coverage of the whole stomach on daily CBCT images [daily clinical target volume (CTV)], which was delineated individually by two observers. We evaluated V95% (percentage of volume receiving ≥95% of the prescribed dose) of daily CTV.

Results:

In total, 102 fractions from 6 patients were assessed. The mean V95% of daily CTV was 97.2%, which was over 95%. In two of six patients, the V95% of daily CTV was over 95% for either observer in all fractions. One patient had significant interobserver variation (p = 0.013). In 95 fractions (93%), the V95% of daily CTV was over 95% for either observer.

Conclusion:

Daily target coverage for CTV in BH-IGRT for gastric lymphoma seems to be favorable, even when using CBCT.

Advances in knowledge:

A previous study ascertained good daily target coverage in BH-IGRT for gastric lymphoma using in-room CT. Even when using CBCT in our study, daily target coverage for CTV in BH-IGRT for gastric lymphoma seems to be favorable.

Introduction

The respiratory motion of abdominal tumors is an obstacle to radiotherapy (RT).1 To assess the respiratory motion, four-dimensional computed tomography (4DCT) is utilized for radiation treatment planning in gastric lymphoma.2,3 Recently, breath-hold image-guided radiotherapy (BH-IGRT) has been applied to treat gastric lymphoma to overcome the respiratory motion and reduce radiation doses for normal tissues.4,5 It is important to assess whether the target is irradiated properly but data on daily target coverage of radiation is limited in BH-IGRT for gastric lymphoma. A previous study, using in-room computed tomography (CT), reported good daily target coverage.6 Data regarding daily target coverage using cone-beam CT (CBCT) are needed as in-room CT is not available in every institution; in contrast CBCT is widely used.7,8 Therefore, we studied the daily target coverage for gastric lymphoma using CBCT in BH-IGRT.

Methods and materials

Inclusion criteria

This retrospective study was approved by the institutional ethics committee (number 2019-064). The inclusion criteria for this study were as follows: (1) patients with gastric lymphoma; and (2) BH-IGRT was performed using 30.6 Gy in 17 fractions for the whole stomach between 2016 and 2019 in our institution (Kagawa University Hospital).

Radiation treatment planning

Patients abstained from one meal before planning CT. Premedication was not used for planning CT. Patients were fixed using the ESFORM immobilization system (Engineering System, Nagano, Japan). As reported previously, in studies of BH-IGRT,9,10 we used a visual feedback method for breath-hold (BH) with the Real-time Positioning Management system (Varian Medical Systems, Palo Alto, CA) and video goggles. The schema of our visual feedback system is shown in Figure 1. We obtained three sets of breath-hold computed tomography (BH-CT) images to confirm the reproducibility of BH for each patient. We delineated the whole stomach on the three sets of BH-CT images. The three delineated whole stomach was defined as the clinical target volume (CTV). The planning target volume (PTV) was made by CTV plus a 0.8 cm margin. The dose prescription at the isocenter was 30.6 Gy in 17 fractions using 4–5 non-coplanar 10 MV photon beams from a linear accelerator (Clinac iX; Varian Medical Systems, Palo Alto, CA).

Figure 1.

Figure 1.

Schema of our visual feedback system. Through capturing the display on the Real-time Positioning Management system with a video camera in real time, the same display can be seen on the patient’s video goggles. Using the bar of instant respiratory position, we can instruct the patient in the timing of the breath-hold.

Daily treatment

Patients abstained from one meal before daily BH-IGRT. Premedication was not used for daily BH-IGRT. After manual setup using a laser, two orthogonal kilovoltage (kV) radiographs were obtained using the On-Board Imaging System equipped with a linear accelerator. Radiological technologists matched manually the position of the bone structures in the left-right, anteroposterior, and craniocaudal axis using the two orthogonal kV radiographs. After the bone matching, CBCT equipped with a linear accelerator for each fraction was performed with a rotation angle of 204 degrees by splitting the gantry rotation into several BHs.11,12 Typically, patients needed three times BHs for CBCT acquisition: each BH was approximately 10 s. After CBCT images were obtained, radiation oncologists and radiological technologists matched manually the position of the daily whole stomach within the PTV. An example of the position matching is shown in Figure 2. After matching, each fraction was delivered.

Figure 2.

Figure 2.

Example of the position matching: (a) Planning breath-hold computed tomography image; (b) Blended image of (a) and (c); (c) Daily BH-CBCT image. Using the daily BH-CBCT image, radiation oncologists and radiological technologists matched the position of the daily whole stomach within the planning target volume (black bold line). BH-CBCT, breath-hold cone-beam computed tomography.

Daily target coverage

As a previous study reported daily target coverage using in-room CT,6 we assessed daily target coverage of the whole stomach on daily CBCT images (daily CTV). According to the American College of Radiology and the American Society for Radiation Oncology practice parameter for IGRT, an accurate PTV ensures that the prescribed dose is actually delivered to the CTV.13 Therefore, we were particularly cautious to deliver the actual doses to the daily CTV as daily target coverage.

Considering interobserver variations in gastric delineation,14 daily CTV was delineated individually by two radiation oncologists as observers 1 (ST) and 2 (TN).

Similar to a previous study on daily target coverage using in-room CT,6 we also evaluated the coverage of daily PTV that was made by daily CTV plus a 0.8 cm margin which was the same margin used for our radiation treatment planning.

Statistics

In a previous study on daily target coverage using in-room CT,6 we evaluated the V95% (percentage of volume receiving ≥95% of the prescribed dose) of daily CTV and daily PTV using CBCT. Interobserver variations were analyzed using Wilcoxon’s rank-sum test. Statistical significance was defined at p < 0.05. We used JMP Pro v. 14 (SAS Institute, Cary, NC) for statistical analyses.

Results

We assessed six patients who met the inclusion criteria: the median age was 64 years (range, 47–75 years), three patients were male and three female, and the Eastern Cooperative Oncology Group Performance Status of 0.

V95% of the daily CTV for each patient and each observer is listed in Table 1. In total, 102 fractions were assessed; mean V95% of daily CTV in all fractions was 97.2%, which was over 95%. In two of six patients, the V95% of daily CTV was over 95% for either observer in all fractions. One patient had significant interobserver variation in daily CTV (p = 0.013); for this patient, the boundary between the stomach and the colon was vague on the daily CBCT images because of gas in both organs.

Table 1.

V95% of daily CTV and daily PTV for each patient and each observera

Pt 1 Pt 2 Pt 3 Pt 4 Pt 5 Pt 6
Obs 1 Obs 2 Obs 1 Obs 2 Obs 1 Obs 2 Obs 1 Obs 2 Obs 1 Obs 2 Obs 1 Obs 2
Mean V95% of daily CTV (%) 96.3 96.7 96.8 97.1 92.4 97.0 98.1 98.5 99.1 98.7 98.0 98.0
Median V95% of daily CTV (%) 98.7 98.7 97.7 98.3 94.7 97.9 98.5 98.9 99.3 99.1 98.6 98.6
Interquartile range for V95% of daily CTV (%) 95.9–98.9 97.2–98.9 95.7–98.5 97.4–98.6 89.0–97.1 96.8–98.1 97.5–99.1 97.9–99.4 98.7–99.4 98.5–99.3 97.9–99.2 98.3–99.2
Range for V95% of daily CTV (%) 72.6–99.5 77.8–99.4 89.6–99.0 83.6–98.9 80.9–99.4 89.1–99.2 94.0–99.2 95.7–99.6 98.6–99.5 94.2–99.6 92.9–100 93.3–99.4
p-value for interobserver variations in daily CTV 0.972 0.428 0.013 0.178 0.312 0.904
Mean V95% of daily PTV (%) 89.5 91.5 90.8 92.1 82.1 88.8 91.0 92.2 96.4 95.2 90.5 91.5
Median V95% of daily PTV (%) 92.3 95.2 90.1 93.5 81.5 87.4 91.2 93.6 96.6 96.3 91.0 91.8
Interquartile range for V95% of daily PTV (%) 85.3–96.2 88.0–96.8 89.2–94.5 90.0–96.6 77.8–87.1 85.0–94.0 90.0–92.6 90.3–94.2 94.7–97.9 93.7–96.9 89.0–91.7 89.6–93.1
Range for V95% of daily PTV (%) 65.1–98.0 67.1–98.8 80.7–97.0 75.4–97.6 72.4–91.0 80.6–96.1 82.4–94.8 84.1–95.8 92.3–99.0 89.4–99.5 85.6–95.8 86.6–97.1
p value for interobserver variations in daily PTV 0.301 0.208 0.003 0.163 0.379 0.202

CTV, Clinical target volume; Obs, Observer; PTV, Planning target volume; Pt, Patient; V95%, Percentage of volume receiving ≥95% of the prescribed dose.

a

Considering interobserver variations, daily CTV was delineated individually by two radiation oncologists as observers 1 (ST) and 2 (TN).

In 95 fractions (93%), the V95% of daily CTV was over 95% for either observer. Conversely, V95% of daily CTV was under 95% for both observers in seven fractions (7%). The causes of the seven fractions were as follows: (i) partial dilatation of the stomach by gas (four fractions); (ii) partial positional shift of the stomach by retained stool in the colon (two fractions); and (iii) partial deformation of the stomach (one fraction).

V95% of the daily PTV for each patient and each observer is also listed in Table 1. The mean V95% of daily PTV in all fractions was 91.0%. Significant interobserver variation in daily PTV (p = 0.003) was observed in one patient, who was the same patient with significant interobserver variation in daily CTV.

Discussion

To the best of our knowledge, this is the first study to investigate daily target coverage using CBCT in BH-IGRT for gastric lymphoma, although BH-IGRT is not a new delivery technique and CBCT is a very popular modality in IGRT.7,8

It is important to irradiate the target properly; however, data on daily target coverage of radiation are limited in BH-IGRT for gastric lymphoma. A previous study reported good daily target coverage in BH-IGRT for gastric lymphoma.6 In this study, daily target coverage was evaluated using in-room CT.6 Commonly, in-room CT is not available in every institution, but CBCT is widely used.7,8 Therefore, we decided to conduct our study as data regarding daily target coverage using CBCT are needed. A comparison of a previous study using in-room CT6 with our study using CBCT is listed in Table 2. Both methods and results seem comparable; mean V95% of daily CTV was 98.5 and 97.2%, respectively, which was over 95% in both studies.

Table 2.

Comparison of a previous study6 with our study

Previous study6 Our study
Institution Single institution Single institution
Patients 12 patients six patients
Fasting At least 4 h before CT and RT Abstained from one meal before CT and RT
BH-CT images at planning CT Three sets Three sets
BH method Visual feedback method Visual feedback method
CTV Whole stomach Whole stomach
PTV CTV plus 0.5–1 cm CTV plus 0.8 cm
Prescribed dose 30 Gy (1.5–2 Gy/fraction); D95% prescribing methoda 30.6 Gy (1.8 Gy/fraction); isocenter-prescribing methodb
Daily CT for BH-IGRT In-room CT CBCT
Observer for the study One observer Two observersc
Mean V95% of daily CTV (%) 98.5 97.2
Mean V95% of daily PTV (%) 94.9 91.0

BH, Breath-hold; BH-CT, Breath-hold computed tomography; BH-IGRT, Breath-hold image-guided radiotherapy; CBCT, Cone-beam computed tomography; CT, Computed tomography; CTV, Clinical target volume; PTV, Planning target volume; RT, Radiotherapy; V95%, Percentage of volume receiving ≥95% of the prescribed dose.

*>95%of the PTV was covered by the prescription dose.

a

>95%of the PTV was covered by the prescription dose.

b

The prescribed dose was delivered to the isocenter.

c

Considering interobserver variations, daily CTV was delineated individually by two radiation oncologists as observers 1 (ST) and 2 (TN) in our study.

Although we obtained comparable results for daily CTV, in 7% of all fractions in our study, V95% of daily CTV was under 95% for both observers. The main reasons were: (1) partial dilatation of the stomach by gas and (2) partial positional shift of the stomach by retained stool in the colon. Although we did not use premedication for planning CT and daily BH-IGRT, we should consider using premedication to reduce stomach gas and retained stool for further improvement of daily target coverage for CTV.

Daily PTV was also evaluated in the previous study.6 Generally, PTV includes a geometric setup margin and internal target volume (ITV), which is the volume encompassing CTV; this takes into account the fact that CTV varies in position, shape, and size because of physiological factors (respiration, heartbeat, bowel motility, gastric filling).13 Although we can minimize the daily setup error and gastric internal motion at the time of CBCT using BH-IGRT, daily intrafractional uncertainties after CBCT and during irradiation remain. To overcome the daily intrafractional uncertainties, daily PTV might also be important. For mean V95% of daily PTV, there seemed to be a difference between the previous study6 and our study (94.9 and 91.0%, respectively). We think that this was caused by the difference in dose prescribing methods; in a previous study,6 >95% of the PTV was covered by the prescription dose (D95% prescribing method); in our study, the prescribed dose was delivered to the isocenter (isocenter-prescribing method). It is known that dosimetric parameters for PTV such as mean dose, D95%, and V90% are higher with the D95% prescribing method than the isocenter-prescribing method.15 To further improve the daily target coverage for PTV, we should consider using the D95% prescribing method.

Apart from the stomach, BH-IGRT could be applied for lymphoma of the mediastinum. A study compared no IGRT and BH-IGRT using in-room CT or CBCT for mediastinal lymphoma.16 The study showed that although the setup difference between no IGRT and BH-IGRT was measurable, it was not clear whether in-room CT offered an advantage over CBCT in reducing the setup margins: the margin with no IGRT ranged from 7.0 to 17.1 mm, that with in-room CT, from 2.2 to 11.6 mm, and that with CBCT, from 3.6 to 11.1 mm.16 The above-discussed comparison between in-room CT6 and CBCT for gastric lymphoma seems to be consistent with the results for mediastinal lymphoma.16

As for the pros and cons of in-room CT and CBCT, these modalities have the following same advantages: (i) can be used for monitoring patient setup (interfraction motion) and changes in anatomy that have occurred possibly during treatment, by performing imaging immediately after treatment; and (ii) have the ability to monitor tumor response through the course of therapy.17 Meanwhile, in-room CT is not available in every institution, but CBCT is widely used.7,8 However, CBCT has several disadvantages: (1) suffers from artifacts in the presence of high-density materials (e.g. hip prostheses), and (2) patient scatter (especially for larger patients) can degrade image quality.17 These cons of CBCT may be a limitation to our study. Considering interobserver variations in gastric delineation,14 daily CTV was delineated individually by two observers in our study. As a result, one patient had significant interobserver variation; in the patient, the boundary between the stomach and the colon was vague on the daily CBCT images because of the presence of gas in both organs. It is known that intensified scatter artifacts lower the image quality of CBCT, although CBCT is clinically well-established on IGRT.18 The image quality of CBCT may influence interobserver variations by obscuring the organ boundaries. This study had some other limitations: a small number of patients and retrospective single institutional design.

Conclusion

Daily target coverage for CTV in BH-IGRT for gastric lymphoma seems to be favorable, even when using CBCT.

Footnotes

Funding: This work was partly supported by JSPS KAKENHI Grant Number JP17K10481.

Contributor Information

Shigeo Takahashi, Email: shigeot@med.kagawa-u.ac.jp.

Takamasa Nishide, Email: tnishide@med.kagawa-u.ac.jp.

Masato Tsuzuki, Email: ney@med.kagawa-u.ac.jp.

Hiroki Katayama, Email: k-hiroki@med.kagawa-u.ac.jp.

Masahide Anada, Email: anada-m@med.kagawa-u.ac.jp.

Toshifumi Kinoshita, Email: kanikoro_taym_8361@yahoo.co.jp.

Shohei Kozai, Email: s-kozai@med.kagawa-u.ac.jp.

Toru Shibata, Email: tshibata@med.kagawa-u.ac.jp.

REFERENCES

  • 1.Takahashi S, Anada M, Kinoshita T, Shibata T. Respiratory motion of lymph node stations in pancreatic cancer: analyses using contrast-enhanced four-dimensional computed tomography. Radiother Oncol 2018; 128: 569–74. doi: 10.1016/j.radonc.2018.05.007 [DOI] [PubMed] [Google Scholar]
  • 2.Matoba M, Oota K, Toyoda I, Kitadate M, Watanabe N, Tonami H. Usefulness of 4D-CT for radiation treatment planning of gastric MZBCL/MALT. J Radiat Res 2012; 53: 333–7. doi: 10.1269/jrr.11127 [DOI] [PubMed] [Google Scholar]
  • 3.Toya R, Saito T, Shimohigashi Y, Yotsuji Y, Matsuyama T, Watakabe T, et al. Four-dimensional cone-beam computed tomography-guided radiotherapy for gastric lymphoma. Jpn J Radiol 2018; 36: 159–63. doi: 10.1007/s11604-017-0698-8 [DOI] [PubMed] [Google Scholar]
  • 4.Choi SH, Park SH, Lee JJB, Baek JG, Kim JS, Yoon HI. Combining deep-inspiration breath hold and intensity-modulated radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: Dosimetric evaluation using comprehensive plan quality indices. Radiat Oncol 2019; 14: 59. doi: 10.1186/s13014-019-1263-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Christopherson KM, Gunther JR, Fang P, Peterson SL, Roach KE, Wong P-F, et al. Decreased heart dose with deep inspiration breath hold for the treatment of gastric lymphoma with IMRT. Clin Transl Radiat Oncol 2020; 24: 79–82. doi: 10.1016/j.ctro.2020.05.013 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Wang H, Milgrom SA, Dabaja BS, Smith GL, Martel M, Pinnix CC. Daily CT guidance improves target coverage during definitive radiation therapy for gastric MALT lymphoma. Pract Radiat Oncol 2017; 7: e471–8. doi: 10.1016/j.prro.2017.03.001 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Nabavizadeh N, Elliott DA, Chen Y, Kusano AS, Mitin T, Thomas CR, et al. Image guided radiation therapy (IGRT) practice patterns and IGRT's impact on workflow and treatment planning: results from a national survey of American Society for radiation oncology members. Int J Radiat Oncol Biol Phys 2016; 94: 850–7. doi: 10.1016/j.ijrobp.2015.09.035 [DOI] [PubMed] [Google Scholar]
  • 8.Batumalai V, Holloway LC, Kumar S, Dundas K, Jameson MG, Vinod SK, et al. Survey of image-guided radiotherapy use in Australia. J Med Imaging Radiat Oncol 2017; 61: 394–401. doi: 10.1111/1754-9485.12556 [DOI] [PubMed] [Google Scholar]
  • 9.Nakamura M, Shibuya K, Shiinoki T, Matsuo Y, Nakamura A, Nakata M, et al. Positional reproducibility of pancreatic tumors under end-exhalation breath-hold conditions using a visual feedback technique. Int J Radiat Oncol Biol Phys 2011; 79: 1565–71. doi: 10.1016/j.ijrobp.2010.05.046 [DOI] [PubMed] [Google Scholar]
  • 10.Peng Y, Vedam S, Chang JY, Gao S, Sadagopan R, Bues M, et al. Implementation of feedback-guided voluntary breath-hold gating for cone beam CT-based stereotactic body radiotherapy. Int J Radiat Oncol Biol Phys 2011; 80: 909–17. doi: 10.1016/j.ijrobp.2010.08.011 [DOI] [PubMed] [Google Scholar]
  • 11.Boda-Heggemann J, Fleckenstein J, Lohr F, Wertz H, Nachit M, Blessing M, et al. Multiple breath-hold CBCT for online image guided radiotherapy of lung tumors: simulation with a dynamic phantom and first patient data. Radiother Oncol 2011; 98: 309–16. doi: 10.1016/j.radonc.2011.01.019 [DOI] [PubMed] [Google Scholar]
  • 12.Kawahara D, Ozawa S, Nakashima T, Tsuda S, Ochi Y, Okumura T, et al. Interfractional diaphragm changes during breath-holding in stereotactic body radiotherapy for liver cancer. Rep Pract Oncol Radiother 2018; 23: 84–90. doi: 10.1016/j.rpor.2018.01.007 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Luh JY, Albuquerque KV, Cheng C, Ermoian RP, Nabavizadeh N, Parsai H, et al. ACR-ASTRO practice parameter for image-guided radiation therapy (IGRT. Am J Clin Oncol 2020; 43: 459–68. doi: 10.1097/COC.0000000000000697 [DOI] [PubMed] [Google Scholar]
  • 14.Jansen EPM, Nijkamp J, Gubanski M, Lind PARM, Verheij M. Interobserver variation of clinical target volume delineation in gastric cancer. Int J Radiat Oncol Biol Phys 2010; 77: 1166–70. doi: 10.1016/j.ijrobp.2009.06.023 [DOI] [PubMed] [Google Scholar]
  • 15.Mizowaki T, Hatano K, Hiraoka M. Surveillance on interfacility differences in dose-prescription policy of intensity-modulated radiation therapy plans for prostate cancer. J Radiat Res 2012; 53: 608–14. doi: 10.1093/jrr/rrs016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Aristophanous M, Chi P-CM, Kao J, Williamson R, Tung S, Andraos T, et al. Deep-Inspiration Breath-Hold intensity modulated radiation therapy to the mediastinum for lymphoma patients: setup uncertainties and margins. Int J Radiat Oncol Biol Phys 2018; 100: 254–62. doi: 10.1016/j.ijrobp.2017.09.036 [DOI] [PubMed] [Google Scholar]
  • 17.De Los Santos J, Popple R, Agazaryan N, Bayouth JE, Bissonnette J-P, Bucci MK, et al. Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery. Int J Radiat Oncol Biol Phys 2013; 87: 33–45. doi: 10.1016/j.ijrobp.2013.02.021 [DOI] [PubMed] [Google Scholar]
  • 18.Srinivasan K, Mohammadi M, Shepherd J. Applications of linac-mounted kilovoltage cone-beam computed tomography in modern radiation therapy: a review. Pol J Radiol 2014; 79: 181–93. doi: 10.12659/PJR.890745 [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from BJR Open are provided here courtesy of Oxford University Press

RESOURCES