Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1988 Nov-Dec;9(6):1149-55.

Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.

L F Czervionke 1, D L Daniels 1, F W Wehrli 1, L P Mark 1, L E Hendrix 1, J A Strandt 1, A L Williams 1, V M Haughton 1
PMCID: PMC8331920  PMID: 3143237

Abstract

Artifacts related to magnetic susceptibility differences between bone and soft tissue are prevalent on gradient-recalled echo images, particularly when long echo delay times are used. These susceptibility artifacts spatially distort and artifactually enlarge bone contours. This can alter the apparent shape of the spinal canal and exaggerate the degree of spinal stenosis seen in patients with cervical spondylosis. The effects of magnetic susceptibility artifacts in gradient echo imaging were studied in a phantom model and the results were correlated with MR images obtained in patients with cervical spondylosis.

Full Text

The Full Text of this article is available as a PDF (3.3 MB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology