Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1994 Oct;15(9):1618-23.

A pitfall in detection of intracranial unruptured aneurysms on three-dimensional phase-contrast MR angiography.

Y Araki 1, E Kohmura 1, I Tsukaguchi 1
PMCID: PMC8333731  PMID: 7847204

Abstract

We report three cases of intracranial unruptured aneurysm evaluated with MR angiography using both three-dimensional time-of-flight and three-dimensional phase-contrast techniques. It has been said that the phase-contrast technique has advantages over the time-of-flight technique in the detection of intracranial aneurysms. However, in our three cases, three-dimensional time-of-flight MR angiography clearly showed the intracranial unruptured aneurysms, but three-dimensional phase-contrast MR angiography failed to show them.

Full Text

The Full Text of this article is available as a PDF (3.4 MB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology