Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1983 May-Jun;4(3):678-80.

Duplex sonography in the evaluation of carotid artery disease.

J N Dreisbach, C E Seibert, S F Smazal, A T Stavros, R J Daigle
PMCID: PMC8334949  PMID: 6410830

Abstract

High-resolution duplex sonography was compared with biplane magnified carotid angiography in a prospective evaluation of 161 carotid arteries in 86 patients. The duplex scanner combined real-time B-mode imaging (7.5 MHz) with simultaneous range-gated pulsed Doppler frequency analysis (3 MHz). The degree of stenosis was usually determined by the true and residual lumen of the carotid artery at the atherosclerotic plaque on the transverse image. The Doppler frequency signals were automatically converted to velocity data by a minicomputer. The accuracy of the duplex system in detecting and assessing stenoses graded in 20% increments is demonstrated according to specificity, sensitivity, and positive and negative predictive value by both cumulative and subgroup analyses. A 93.7% sensitivity was shown for minimal (0-20%) stenosis and 100% sensitivity for severe (greater than 60%) stenosis. An apparent limitation of duplex sonography is the differentiation of a high-grade stenosis from occlusion (sensitivity, 82.6%; positive predictive value, 90.4%).

Full Text

The Full Text of this article is available as a PDF (1.6 MB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology

RESOURCES