Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1996 Apr;17(4):639-50.

Quantitative high-resolution measurement of cerebrovascular physiology with slip-ring CT.

L M Hamberg 1, G J Hunter 1, E F Halpern 1, B Hoop 1, G S Gazelle 1, G L Wolf 1
PMCID: PMC8337271  PMID: 8730182

Abstract

PURPOSE

To implement and validate spiral slip-ring CT for use in cerebrovascular studies.

METHODS

Continuous data were acquired from an experimental, first-pass, iodine contrast, bolus study by unidirectional X-ray tube rotation, and images were reconstructed at 100-millisecond intervals. Functional maps of cerebral blood volume (CBV) and cerebral blood flow (CBF) were constructed with voxel-by-voxel gamma variate fitting. Reproducibility studies, different injection volumes and sites, and CO2 challenge were applied to verify the technique.

RESULTS

Average absolute cortical gray and white matter and basal ganglia results were reproducible within +/- 0.8 ml/100 g for CBV and +/- 20 ml/100 g per minute for CBF, CBV response to changing arterial CO2 tension was significant only in cortical gray matter and basal ganglia; CBF response was significant in gray and white matter, as well as in the basal ganglia.

CONCLUSION

Functional CT and constructed functional maps provide an optimal, high-resolution tool with which to visualize cerebrovascular parameters and their changes.

Full Text

The Full Text of this article is available as a PDF (614.9 KB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology

RESOURCES