Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1998 Apr;19(4):739-41.

Three-dimensional fast spin-echo MR of the inner ear: ultra-long echo train length and half-Fourier technique.

S Naganawa 1, T Itoh 1, H Fukatsu 1, T Ishigaki 1, T Nakashima 1, Y Kassai 1, M Miyazaki 1, H Takai 1
PMCID: PMC8337392  PMID: 9576665

Abstract

We compared the image quality of the newly developed ultra-long echo train length (ETL) 3-D fast spin-echo (FSE) and half-Fourier technique, which is performed in less than 3 minutes, with the conventional 3D-FSE imaging technique, which takes 15 minutes, in assessing MR examinations of the inner ear. The new method's images were almost comparable to the conventional 3D-FSE images in depicting anatomic details and pathologic findings. Implementation of the ultra-long ETL and half-Fourier 3D-FSE imaging technique enables acquisition of inner ear MR studies in a vastly reduced time and with high spatial resolution without significant penalty, opening the possibility for low-cost screening of acoustic tumors without contrast enhancement in less than 3 minutes.

Full Text

The Full Text of this article is available as a PDF (377.8 KB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology

RESOURCES