Skip to main content
AJNR: American Journal of Neuroradiology logoLink to AJNR: American Journal of Neuroradiology
. 1998 Apr;19(4):701-6.

Perineural spread of head and neck tumors: how accurate is MR imaging?

W R Nemzek 1, S Hecht 1, R Gandour-Edwards 1, P Donald 1, K McKennan 1
PMCID: PMC8337413  PMID: 9576658

Abstract

PURPOSE

Our aim was to determine the precision of MR imaging evaluation of perineural spread of head and neck tumors.

METHODS

Nineteen patients had complete extirpation of head and neck tumors (10 squamous cell carcinomas, four adenoid cystic carcinomas, one poorly differentiated carcinoma, one salivary duct carcinoma, one mucoepidermoid carcinoma, one chordoma, and one meningioma) with histologic confirmation of perineural spread. Findings at presurgical contrast-enhanced MR imaging were compared with findings at pathologic examination.

RESULTS

The sensitivity of MR imaging for detection of perineural spread was 95%; however, the sensitivity for mapping the entire extent of perineural spread fell to 63%.

CONCLUSION

MR imaging may fail to depict microscopic foci of perineural tumor infiltration, leading to underestimation of the extent of perineural spread. Nevertheless, with careful analysis of foraminal architecture and MR enhancement patterns, one can reliably identify the presence if not the extent of perineural spread.

Full Text

The Full Text of this article is available as a PDF (651.2 KB).


Articles from AJNR: American Journal of Neuroradiology are provided here courtesy of American Society of Neuroradiology

RESOURCES