Skip to main content
Oxford University Press - PMC COVID-19 Collection logoLink to Oxford University Press - PMC COVID-19 Collection
. 2021 Jun 30:jfab081. doi: 10.1093/jalm/jfab081

Evaluation of Inappropriate COVID-19 RT-PCR Test Utilization at an academic medical center

Naomi L Hardy 1,, Paul M Luethy 1
PMCID: PMC8344747  PMID: 34191020

Abstract

Background

An evolving COVID-19 testing landscape and issues with test supply allocation, especially in the current pandemic, has made it challenging for ordering providers. We audited orders of the Xpert® Xpress SARS-CoV-2 RT-PCR platform—the fastest of several other testing modalities available—to illuminate these challenges utilizing a multidisciplinary laboratory professional team consisting of a pathology resident and microbiology lab director.

Methods

Retrospective review of the first five hundred Xpert® Xpress SARS-CoV-2 RT-PCR test orders from a 2-week period to determine test appropriateness based on the following indications: emergency surgery, emergent obstetric procedures, initial behavioral health admission, and later including discharge to skilled care facilities and pediatric admissions. Our hypothesis was that a significant proportion of orders for this testing platform were inappropriate.

Results

Upon review, a significant proportion of orders were incorrect, with 69.8% (n = 349, p < 0.0001) not meeting indications for rapid testing. Of all orders, 249 designated as emergency surgery were inappropriate, with 49.0% of those orders never proceeding with any surgical intervention; most of these were trauma related (64.6% were orders associated with a trauma unit).

Conclusions

Significant, pervasive inappropriate ordering practices were identified at this center. A laboratory professional team can be key to identifying problems in testing and play a significant role in combating inappropriate test utilization.


Articles from The Journal of Applied Laboratory Medicine are provided here courtesy of Oxford University Press

RESOURCES