Abstract
Background
Watertight closure of the dura mater is fundamental in neurosurgery. Besides the classical suturing techniques, a variety of biomaterials have been proposed as sealants. Platelet rich fibrin (PRF) is an autologous biomaterial which can readily be obtained through low-speed centrifugation of patient’s own blood. It is rich in fibrin, growth factors, leucocytes and cytokines and has shown adhesive properties while promoting the physiological wound healing process. In this study, we investigated the effect of applying PRF in reinforcing the watertight dura mater closure.
Methods
We created an in vitro testing device, where the watertight dura mater closure could be hydrostatically assessed. On 26 fresh harvested bovine dura maters, a standardised 20-mm incision was closed with a running suture, and the leak pressure was measured first without (primary leak pressure) and then with PRF augmentation (secondary leak pressure). The two groups of measurements have been statistically analysed with the Student’s paired t test.
Results
The “running suture only group” had a leak pressure of 10.5 ± 1.2 cmH2O (mean ± SD) while the “PRF-augmented group” had a leak pressure of 47.2 ± 2.6 cm H2O. This difference was statistically significant (p < 0.001; paired t test).
Conclusions
Autologous platelet rich fibrin augmentation reliably reinforced watertight closure of the dura mater to a > 4-fold increased leak pressure after failure of the initial standard running suture technique.
Electronic supplementary material
The online version of this article (10.1007/s00701-020-04254-4) contains supplementary material, which is available to authorized users.
Keywords: Watertight Dural closure, Dural onlays, Autologous biomaterial, Neurosurgery
Introduction
To avoid complications associated with cerebrospinal fluid (CSF) leak after neurosurgical operations, watertight dura mater closure is fundamental [1]. Postoperative CSF leakage can result in meningitis, wound-related problems and other complications such as intracranial hypotension. In addition, dural healing is furthermore important for future revision-operations or possible adjuvant treatments in the operated area. Various suturing techniques and reinforcements with bio-products have been suggested and tested over the years [13, 12, 18–20].
Platelet rich fibrin (PRF) is a new generation of autologous platelet concentrates, without biochemical blood handling. It is rich in fibrin, leukocytes, cytokines and growth factors which accelerate and promote the natural wound healing while preventing the local occurrence of infections [3, 7, 9–11, 18, 19, 31]. First generation of blood concentrates systems such as plasma-rich growth factors (PRGF) and platelet-rich plasma (PRP) involved secondary processing with non-autologous anticoagulants, multi-step centrifugations and elimination of leucocytes [2, 14, 30].
PRF serves as an autologous bio-scaffold and reservoir of growth factors for tissue regeneration, allowing cells to migrate and proliferate faster [22]. All the known clinical applications of PRF highlight an accelerated tissue healing due to the development of effective neovascularisation, accelerated wound closing with fast cicatricial tissue remodelling and reduction of infectious events [6].
PRF can be prepared in two different textures either fluid or solid, according to the updated protocol of Choukroun and Ghanaati in 2018, after a single cycle of low-speed centrifugation [5].
The solid-PRF (s-PRF, Fig. 1(A, C) comprises an elastic 3D fibrin-matrix. It can be shaped through mechanical manipulation as needed, to fit its use. The injectable-PRF (i-PRF, Fig. 1(B)) comprises a fibrin matrix in an intermediate phase. i-PRF has a high viscosity and gradually becomes gelatinous after removal from its preparation vial.
Fig. 1.
(A) s-PRF resulting fibrin clot, (B) Isolation of the i-PRF. (C) s-PRF fibrin clot after flattening through mechanical compression
In addition to its wound-healing properties, autologous fibrin is widely used in various surgical fields (ophthalmology, orthopaedic and vascular surgery) as a sealant due to its tissue-adhesive properties. Consequently, PRF may serve as an intraoperative glue to immediately enhance the watertightness of dural suture [8, 15, 17, 32].
In this study, we present an in vitro set-up to investigate, whether augmenting the classical dura suture with a combination of PRF in both states can result in a stronger watertightness in cases of simulated increased intracranial pressures.
Materials and methods
Dura testing device and sample installation
We developed a testing device to determine the leak pressure of a dural suture. (Fig. 2(A, B)).
Fig. 2.
(A) Application of the dural sample on the testing chamber. (B) Clammed dural sample. (C) 20-mm dural incision and air decompression by filling up the chamber. (D) Dural sample after running suture
A transparent plastic reversed flat top cone-shaped container with an opening of 4.5 cm was equipped with two luer lock connections, both ~ 1 cm above the bottom. One was used as input through which Evans-blue-dyed saline solution could be injected with a syringe. The other was connected to a hydrostatic pressure measuring column to assess the intra-chamber pressure. The collected dura samples were placed as shown in Fig. 2(A) on the opening of the container and then water-tight clamped with a tightly fitting plastic ring Fig. 2(B).
Twenty-six fresh bovine dura preparations (10 cm × 10 cm) were harvested from 4- to 6-month-old bovine skulls, from the central meat processing unit in the city of Freiburg and kept refrigerated at 4 °C in saline. All experiments were conducted within 1 week after the dural harvesting.
Preparation of solid and injectable PRF biomaterial
For every dura closure, we used one vial for solid and one for injectable PRF, each containing 10 ml of healthy volunteer’s human blood and centrifuged in the DUO centrifuge (process for PRF, Nice, France) according to the low centrifugation concept protocol of Choukroun and Ghanaati [5]. This centrifuge has a fixed angle rotor with a radius of 110 mm. According to the aforementioned protocol, blood was centrifuged at 1200 rpm for 8 min (177 g). All donors had no signs of infectious disease. None of the healthy volunteers used any anticoagulants.
Sterile plastic tubes (process for PRF, Nice, France), with a volume of 10 ml were used for the preparation of the fluid (injectable) PRF, while 10-ml sterile glass tubes (process for PRF, Nice, France), were used for the preparation of the solid PRF. Both tubes were centrifuged as previously described for 8 min at 1200 rpm. Blood was drawn by means of a clinically approved butterfly blood collection method. Centrifugation was initiated with no delays, directly after blood collection, over a total time of 2–3 min maximum.
After completion of the centrifugation process, tubes were left to rest for 5 min in the device. From the glass tubes, a solid PRF matrix (s-PRF) was collected (Fig. 1(A)) and then manually compressed and flattened (Fig. 1(C)). From the plastic tubes, a thick fluid version of the injectable PRF (i-PRF), was aspired in a 10-ml syringe [5].
Measurement of fluid leak pressure
After fixation of the dura samples to the testing device, a validation of the watertight fixation and sample-integrity was performed. No water leak was observed after reaching a pressure of up to 70 cm H2O.
A straight 20-mm incision was performed in the centre of the dura with a number 11 scalpel. The container was then filled to the rim with the blue-dyed saline until no residual air was trapped in the system (Fig. 2(C)).
The incision was sutured with Premicron 4–0 running simple closure suture (with 2 to 3 throws per centimetre using 3 to 4 mm bites, Fig. 2(D)) according to the standards for dura-closure during neurosurgical operations (University Clinic of Freiburg, Department of Neurosurgery). The specification including the quantity of stitches was the same for all sample closures.
After completion of suturing the incised dura-sample, pressure in the chamber was slowly increased by injection of more dyed-saline through the input valve. At the same time the hydrostatic pressure column measured, the intra-chamber pressure increase. By the first visual confirmation of a dura leak through the sutured dura, the measured intra-chamber pressure was documented and defined as the primary-leak-pressure. Then the pressure was again slowly decreased to the point that no dyed water remained above the sutured dura.
In the second phase of the experiment, the flattened solid PRF membrane was applied on top of the sutured incision covering it completely as shown in Fig. 3(I, III).
Fig. 3.
(I) s-PRF membrane applied on the sutured area. (II) Application of the i-PRF on top of the s-PRF membrane. (III) Schematic 1: (A) Dura mater. (B) Dura-suture. (C) s-PRF. (D) i-PRF. (E) Cerebrospinal fluid
Immediately after that, the previously collected injectable PRF was applied drop by drop slowly on top creating a thin layer over the solid PRF membrane (Online Resource - video 1). After 1 min, we proceeded with the same algorithm of gradually increasing the intra-chamber pressure. By the first visual confirmation of a dura leak through the sutured dura, the measured intra-chamber pressure was documented and defined as the secondary-leak-pressure. (Fig. 3(II) and Online Resource - video 2). During this phase of the experiment, two observers were monitoring the chamber and the pressure column respectively. In order to avoid internal errors in cases where small leaks could be masked through the PRF onlay, situations of pressure drop on the column without simultaneous observed leak on the chamber were documented as leak.
ESM 1.
(MPG 68944 kb)
The whole process was visualised and videodocumented with a neurosurgery microscope (Pentero 900 from Zeiss Inc., Superlux® 330 light source with 2 × 300 W xenon). The distance between the microscope and dura mater was 10 cm.
Statistical analysis
Comparison of primary and secondary leak pressure of suture only and PRF-augmented closure was performed using Student’s paired t test. A p value < 0.05 was considered significant.
Results
Primary and secondary leak pressures are presented in Table 1. The “running suture only group” had a mean pressure of 10.5 ± 1.2 cmH2O while the “PRF-augmented group” had a significantly higher mean value of 47.1 ± 2.6 cm H2O (p < 0.001; paired t test) (Fig. 4). In all measurements, the visualised leak on the chamber from the first observer was verified with a concomitant pressure drop on the column recorded by the second observer. In all cases, liquid PRF fully covered the surface of the chamber and the underlying PRF membrane. The concentration of Fibrin on each PRF-application was not evaluated during this study, neither the serum-Fibrin levels of each volunteer. Due to the masking effect of the PRF onlay, a precise localisation of the leak origin along the sutured defect was not possible. In many situations, a small leak was observed under the liquid PRF onlay without bursting through and disrupting its continuity. In these specimens (2, 15 and 16), the initially recorded pressure drop was documented as secondary leak pressure.
Table 1.
Primary and secondary leak pressure measurements
Pressure in cmH2O before fluid leak | ||
---|---|---|
Specimen | Dura-closure with running suture only Primary leak pressure |
PRF augmented dura-closure Secondary leak pressure |
1 | 12 | 40 |
2 | 8 | 35 |
3 | 11 | 45 |
4 | 13 | 55 |
5 | 9 | 52 |
6 | 14 | 55 |
7 | 12 | 45 |
8 | 11 | 48 |
9 | 7 | 47 |
10 | 4 | 40 |
11 | 15 | 55 |
12 | 14 | 45 |
13 | 13 | 50 |
14 | 11 | 44 |
15 | 6 | 37 |
16 | 9 | 34 |
17 | 7 | 44 |
18 | 9 | 48 |
19 | 14 | 52 |
20 | 11 | 45 |
21 | 13 | 46 |
22 | 5 | 45 |
23 | 14 | 51 |
24 | 11 | 53 |
25 | 13 | 58 |
26 | 7 | 57 |
Fig. 4.
Dot plot illustrating leak-pressure measurements (cm H2O) for both closure methods
Discussion
We could show that autologous platelet rich fibrin (PRF) reliably reinforced watertight closure of the dura mater after failure of the initial standard running suture technique. At least 4 times higher leak pressures were achieved by combining solid and fluid PRF as a simple onlay graft in less than 2 min. PRF can be harvested from 10 ml of donor blood after 8 min of centrifugation without any additional chemicals or pharmaceuticals needed. We will further investigate the potential of our combination of solid and fluid PRF as a highly effective, safe, simple, cost-effective substitute for dural reinforcement as well as augmentation of wound healing and for durable dural closure.
In our in vitro setting with a central defect of 20 mm, the maximum leak pressure observed after PRF-augmentation was 58 cmH20. Chauvet et al. in 2011, in a comparable in vitro testing environment, evaluated various commercial sealants and measured maximum leak pressures of 43 cmH20 [4] on a central linear dural-defect of 50 mm. Compared to other in vitro studies of artificial dura sealants, PRF in our experiments showed similar strengthening properties [23, 34].
Other studies have previously highlighted the importance of onlays to ensure a watertight dura closure in spinal [21, 25], supratentorial [29], skull base [28] and transsphenoidal surgery [26]. Intraoperatively, the sealants performance is associated with its adhesive capacity on the dura mater and elasticity, while postoperatively, a bio-integration of the sealant with the healing dura is crucial to preserve the water-tightness. Integrity of dura-healing is especially important in cases where reoperation in the same area may be necessary. Thus, an optimal sealant should not only offer good adhesive, mechanical and water-tightness properties but also promote and support the dura-healing process. In contrast to older protocols of platelet-rich plasma preparations, the second generation PRF, as initially described from Choukroun et al. in 2001, contains a higher number of leukocytes growth factors [24] and key immune cytokines and interconnects naturally with the surrounding tissues, promoting and accelerating all phases of wound healing [16]. PRF’s mechanical properties shown in our study, combined with its possible wound healing effect, makes it an interesting dura-sealing-onlay for further investigation.
A first-generation autologous fibrin tissue adhesive was used on cerebrospinal fluid leak in spinal cord, in a randomised controlled trial and proved safe and superior compared to commercial fibrin tissue adhesives [27]. In this study, 400 ml of patient’s whole blood was drawn prior to surgery, centrifuged and finally intermixed with calcium gluconate and human thrombin before its intraoperative use. The centrifugation procedure involved multiple steps including the removal of the patient’s leukocytes from the final material. In our study, we demonstrated the utilisation of a second-generation platelet concentrate without any use of chemical preservatives or anticoagulants which could be freshly prepared from the patient’s own blood during the operation. This process adds minimal additional costs, and the automated commercialised systems have simplified its utilization in the operating theatre.
In a recent study from Theys et al., solid PRF membranes were utilised as single onlays to reinforce the dural-closure in a clinical setting of 44 brain and spine operations. Among those, a CSF leak was present only after two endoscopic transsphenoidal pituitary and one spinal surgery. Adverse effects associated with the PRF augmentations were not observed. We propose that a combination of both PRF forms could offer a stronger sealing effect [33].
Our study results are limited due to the in vitro nature of our experiments. In vivo elaboration of the technique should be performed in the next step to validate the results for clinical use.
Another limitation of our experimental setup is the perfectly horizontal layer of dura mater which allowed an optimal application of the i-PRF. As i-PRF needs some time to solidify, clinically relevant applications on vertical or inclined dura orientations may present challenges and need further exploration. Our proposed method could be easily applied in spinal surgery where most cases are operated in a prone position. In supratentorial cranial surgery, transient intraoperative adjustments of the operating table could facilitate a proper application of i-PRF.
The lack of a standardised and widely accepted device for in vitro dura-closure testing in the literature, made us create a simple hydrostatic construct lacking electronic circuits, robust and reliable. Our design allowed a watertight fixation of the dura samples, preventing any lateral leakage that could affect our measurements.
In our future work, we aim to compare PRF augmentation with other commercial sealants, in the same experimental setting. If PRF proves to be at least similarly mechanically efficient, and additionally present better tissue-healing properties, it could become an alternative treating option of the neurosurgical armamentarium.
Conclusions
We fabricated an experimental device that allowed us to stress-test our proposed PRF dura augmentation technique in a measurable fashion and compare it to standard dural closure. Autologous platelet rich fibrin augmentation (PRF), compared to the standard running suture technique, significantly reinforced the watertightness of the dura mater closure in vitro.
Electronic supplementary material
(MPG 67.3 mb)
Funding
Open Access funding enabled and organized by Projekt DEAL.
Compliance with ethical standards
Conflict of interest
Vasilikos I., Beck J., Grauvogel J., Nisyrios T., Grapatsas K. and Hubbe U. certify that they have no affiliations with or involvement in any organisation or entity with any financial interest (such as honoraria; educational grants; participation in speakers’ bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licencing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.
Prof. Ghanaati is a medical consultant in Mectron Inc. that produces the PRF-Centrifugation Device used in our experiments.
Ethical approval
All procedures involving human participants were in accordance with the ethical standards of the institutional (University of Freiburg) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
“This article does not contain any studies with human participants performed by any of the authors.”
“All applicable international, national, and institutional guidelines for the care and use of animals were followed.”
Due to the in vitro nature of our experiments, there were no violations of the ARRIVE guidelines or Declaration of Helsinki for animal studies. The acquired bovine dura preparations were by-products of the normal commercial meat processing cycle, which complies with the European regulations. The blood used for the PRF preparation was acquired from healthy volunteers. After consultation with the local ethics committee of the University of Freiburg, no formal approval of the study was required.
Footnotes
This article is part of the Topical Collection on Neurosurgery general
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Change history
9/3/2021
A Correction to this paper has been published: 10.1007/s00701-021-04907-y
References
- 1.Allen KP, Isaacson B, Kutz JW, Purcell PL, Roland PS. The association of meningitis with postoperative cerebrospinal fluid fistula. J Neurol Surg B Skull Base. 2012;73(6):401–404. doi: 10.1055/s-0032-1329618. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Anitua E, Sánchez M, Orive G, Andia I. The potential impact of the preparation rich in growth factors (PRGF) in different medical fields. Biomaterials. 2007;28(31):4551–4560. doi: 10.1016/j.biomaterials.2007.06.037. [DOI] [PubMed] [Google Scholar]
- 3.Bielecki T, Dohan Ehrenfest DM. Platelet-rich plasma (PRP) and platelet-rich fibrin (PRF): surgical adjuvants, preparations for in situ regenerative medicine and tools for tissue engineering. Curr Pharm Biotechnol. 2012;13(7):1121–1130. doi: 10.2174/138920112800624292. [DOI] [PubMed] [Google Scholar]
- 4.Chauvet D, Tran V, Mutlu G, George B, Allain J-M. Study of dural suture watertightness: an in vitro comparison of different sealants. Acta Neurochir. 2011;153(12):2465–2472. doi: 10.1007/s00701-011-1197-9. [DOI] [PubMed] [Google Scholar]
- 5.Choukroun J, Ghanaati S. Reduction of relative centrifugation force within injectable platelet-rich-fibrin (PRF) concentrates advances patients’ own inflammatory cells, platelets and growth factors: the first introduction to the low speed centrifugation concept. Eur J Trauma Emerg Surg. 2018;44(1):87–95. doi: 10.1007/s00068-017-0767-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Choukroun J, Diss A, Simonpieri A, Girard M-O, Schoeffler C, Dohan SL, Dohan AJJ, Mouhyi J, Dohan DM. Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part IV: clinical effects on tissue healing. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006;101(3):e56–e60. doi: 10.1016/j.tripleo.2005.07.011. [DOI] [PubMed] [Google Scholar]
- 7.Cieslik-Bielecka A, Choukroun J, Odin G, Dohan Ehrenfest DM. L-PRP/L-PRF in esthetic plastic surgery, regenerative medicine of the skin and chronic wounds. Curr Pharm Biotechnol. 2012;13(7):1266–1277. doi: 10.2174/138920112800624463. [DOI] [PubMed] [Google Scholar]
- 8.Damiano G, Palumbo VD, Fazzotta S, Buscemi S, Ficarella S, Maffongelli A, Buscemi G, Monte Lo AI. Laparoscopic repair of boundary incisional hernia in a kidney transplant patient: a safe tacks-fibrin glue combined mesh fixation technique. Transplant Proc. 2019;51(1):215–219. doi: 10.1016/j.transproceed.2018.04.084. [DOI] [PubMed] [Google Scholar]
- 9.Dohan Ehrenfest DM, Andia I, Zumstein MA, Zhang C-Q, Pinto NR, Bielecki T. Classification of platelet concentrates (platelet-rich plasma-PRP, platelet-rich fibrin-PRF) for topical and infiltrative use in orthopedic and sports medicine: current consensus, clinical implications and perspectives. Muscles Ligaments Tendons J. 2014;4(1):3–9. doi: 10.32098/mltj.01.2014.02. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Dohan DM, Choukroun J, Diss A, Dohan SL, Dohan AJJ, Mouhyi J, Gogly B. Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part II: platelet-related biologic features. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006;101(3):e45–e50. doi: 10.1016/j.tripleo.2005.07.009. [DOI] [PubMed] [Google Scholar]
- 11.Dohan DM, Choukroun J, Diss A, Dohan SL, Dohan AJJ, Mouhyi J, Gogly B. Platelet-rich fibrin (PRF): a second-generation platelet concentrate. Part I: technological concepts and evolution. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006;101(3):e37–e44. doi: 10.1016/j.tripleo.2005.07.008. [DOI] [PubMed] [Google Scholar]
- 12.Epstein NE. Dural repair with four spinal sealants: focused review of the manufacturers’ inserts and the current literature. Spine J. 2010;10(12):1065–1068. doi: 10.1016/j.spinee.2010.09.017. [DOI] [PubMed] [Google Scholar]
- 13.Esposito F, Angileri FF, Kruse P, Cavallo LM, Solari D, Esposito V, Tomasello F, Cappabianca P. Fibrin sealants in dura sealing: a systematic literature review. PLoS One. 2016;11(4):e0151533. doi: 10.1371/journal.pone.0151533. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Everts PAM, Knape JTA, Weibrich G, Schönberger JPAM, Hoffmann J, Overdevest EP, Box HAM, van Zundert A. Platelet-rich plasma and platelet gel: a review. J Extra Corpor Technol. 2006;38(2):174–187. [PMC free article] [PubMed] [Google Scholar]
- 15.Flumignan R, Guedes Neto H, Araujo S, Giulio YD, Porta C, Amorim J, Nakano L. Fibrin sealant repair of a double-necked femoral pseudoaneurysm. Rev Assoc Med Bras (1992) 2018;64(12):1069–1072. doi: 10.1590/1806-9282.64.12.1069. [DOI] [PubMed] [Google Scholar]
- 16.Ghanaati S, Herrera-Vizcaino C, Al-Maawi S, Lorenz J, Miron RJ, Nelson K, Schwarz F, Choukroun J, Sader R. Fifteen years of platelet rich fibrin in dentistry and oromaxillofacial surgery: how high is the level of scientific evidence? J Oral Implantol. 2018;44(6):471–492. doi: 10.1563/aaid-joi-D-17-00179. [DOI] [PubMed] [Google Scholar]
- 17.Ghazizadeh L, Chevrier A, Farr J, Rodeo SA, Buschmann MD. Augmentation techniques for meniscus repair. J Knee Surg. 2018;31(1):99–116. doi: 10.1055/s-0037-1602247. [DOI] [PubMed] [Google Scholar]
- 18.Graziano F, Certo F, Basile L, Maugeri R, Grasso G, Meccio F, Ganau M, Iacopino DG. Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: part I: intracranial surgical procedure. Surg Neurol Int. 2015;6:77. doi: 10.4103/2152-7806.156871. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Graziano F, Maugeri R, Basile L, Meccio F, Iacopino DG. Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: part II: Vertebro-spinal procedures. Surg Neurol Int. 2016;7(Suppl 3):S77–S82. doi: 10.4103/2152-7806.174894. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Green AL, Arnaud A, Batiller J, Eljamel S, Gauld J, Jones P, Martin D, Mehdorn M, Ohman J, Weyns F. A multicentre, prospective, randomized, controlled study to evaluate the use of a fibrin sealant as an adjunct to sutured dural repair. Br J Neurosurg. 2015;29(1):11–17. doi: 10.3109/02688697.2014.948808. [DOI] [PubMed] [Google Scholar]
- 21.Jankowitz BT, Atteberry DS, Gerszten PC, Karausky P, Cheng BC, Faught R, Welch WC. Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery. Eur Spine J. 2009;18(8):1169–1174. doi: 10.1007/s00586-009-0928-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Kang Y-H, Jeon SH, Park J-Y, Chung J-H, Choung Y-H, Choung H-W, Kim E-S, Choung P-H. Platelet-rich fibrin is a bioscaffold and reservoir of growth factors for tissue regeneration. Tissue Eng A. 2011;17(3–4):349–359. doi: 10.1089/ten.tea.2010.0327. [DOI] [PubMed] [Google Scholar]
- 23.Kawai H, Nakagawa I, Nishimura F, Motoyama Y, Park Y-S, Nakamura M, Nakase H, Suzuki S, Ikada Y. Effectiveness of a new gelatin sealant system for dural closure. Neurol Res. 2014;36(10):866–872. doi: 10.1179/1743132814Y.0000000342. [DOI] [PubMed] [Google Scholar]
- 24.Kobayashi E, Flückiger L, Fujioka-Kobayashi M, Sawada K, Sculean A, Schaller B, Miron RJ. Comparative release of growth factors from PRP, PRF, and advanced-PRF. Clin Oral Investig. 2016;20(9):2353–2360. doi: 10.1007/s00784-016-1719-1. [DOI] [PubMed] [Google Scholar]
- 25.Kumar A, Maartens NF, Kaye AH. Evaluation of the use of BioGlue® in neurosurgical procedures. J Clin Neurosci. 2003;10(6):661–664. doi: 10.1016/S0967-5868(03)00163-2. [DOI] [PubMed] [Google Scholar]
- 26.Kumar A, Maartens NF, Kaye AH. Reconstruction of the sellar floor using Bioglue following transsphenoidal procedures. J Clin Neurosci. 2003;10(1):92–95. doi: 10.1016/S0967-5868(02)00262-X. [DOI] [PubMed] [Google Scholar]
- 27.Nakamura H, Matsuyama Y, Yoshihara H, Sakai Y, Katayama Y, Nakashima S, Takamatsu J, Ishiguro N. The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial. Spine. 2005;30(13):E347–E351. doi: 10.1097/01.brs.0000167820.54413.8e. [DOI] [PubMed] [Google Scholar]
- 28.Nistor RF, Chiari FM, Maier H, Hehl K. The fixed combination of collagen with components of fibrin adhesive-a new hemostypic agent in skull base procedures. Skull Base. 1997;7(1):23–30. doi: 10.1055/s-2008-1058620. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Reddy M, Schöggl A, Reddy B, Saringer W, Weigel G, Matula C. A clinical study of a fibrinogen-based collagen fleece for dural repair in neurosurgery. Acta Neurochir. 2002;144(3):265–269. doi: 10.1007/s007010200034. [DOI] [PubMed] [Google Scholar]
- 30.Sánchez M, Azofra J, Anitua E, Andia I, Padilla S, Santisteban J, Mujika I. Plasma rich in growth factors to treat an articular cartilage avulsion: a case report. Med Sci Sports Exerc. 2003;35(10):1648–1652. doi: 10.1249/01.MSS.0000089344.44434.50. [DOI] [PubMed] [Google Scholar]
- 31.Schär MO, Diaz-Romero J, Kohl S, Zumstein MA, Nesic D. Platelet-rich concentrates differentially release growth factors and induce cell migration in vitro. Clin Orthop Relat Res. 2015;473(5):1635–1643. doi: 10.1007/s11999-015-4192-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Thatte S, Dube AB, Sharma S. Efficacy of autologous serum in fixing conjunctival autografts of various sizes in different types and grades of pterygium. J Ophthalmic Vis Res. 2019;14(2):136–143. doi: 10.4103/jovr.jovr_227_17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Theys T, Van Hoylandt A, Broeckx C-E, Van Gerven L, Jonkergouw J, Quirynen M, van Loon J. Plasma-rich fibrin in neurosurgery: a feasibility study. Acta Neurochir. 2018;160(8):1497–1503. doi: 10.1007/s00701-018-3579-8. [DOI] [PubMed] [Google Scholar]
- 34.van Doormaal T, Kinaci A, van Thoor S, Redegeld S, Bergmann W, van der Zwan A. Usefulness of sealants for dural closure: evaluation in an in vitro model. Oper Neurosurg (Hagerstown) 2018;15(4):425–432. doi: 10.1093/ons/opx260. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
(MPG 67.3 mb)