Endoscopic clipping with polyglycolic acid sheets for colonic diverticulum bleeding.
Abbreviation: PGA, polyglycolic acid
There are various methods of achieving endoscopic hemostasis for diverticular hemorrhage, such as endoscopic clipping1, 2, 3 and band ligation.3, 4, 5, 6 Endoscopic clipping is the most commonly used method. However, direct placement of the hemoclips on the bleeding site is often challenging, and inadequate clipping may lead to early recurrent bleeding. Generally, it is easy to directly place the hemoclips on the exposed vessel when it is visible at the neck of the diverticulum (Fig. 1A). However, it is difficult to directly place the hemoclips on the exposed vessel when it is located at the dome and the diverticular orifice is small (Fig. 1B).6 When direct placement of hemoclips is difficult, indirect placement in a zipper fashion is sometimes performed. However, this may not sufficiently occlude the exposed vessel and may contribute to early recurrent bleeding.3,6
Figure 1.
Endoscopic clipping for the treatment of colonic diverticular bleeding. A, Direct placement of hemoclip for bleeding at the neck of the diverticulum. B, Indirect placement of hemoclip for bleeding in the dome of the diverticulum.
The use of a polyglycolic acid (PGA) sheet (Neoveil; Gunze Medical Division, Kyoto, Japan), a biodegradable suture material, with fibrin glue (Beriplast P combi-Set; CSL Behring Pharma, Tokyo, Japan) has been demonstrated as a method for closing fistulas or wounds in the surgical field.7,8 Their use for treating endoscopic mucosal defects after endoscopic submucosal dissection has recently been increasing.9, 10, 11 However, reports regarding their usefulness for diverticular hemorrhage are lacking. To overcome the shortcomings of the conventional clipping method, we developed a modified clipping method using PGA sheets, in which we placed the hemoclips in a zipper fashion after filling the exposed vessel with PGA sheets (Fig. 2). Here, we report a case of refractory colonic diverticular bleeding managed with a modified clipping method using PGA sheets.
Figure 2.
Endoscopic hemostasis for colonic diverticular bleeding with a modified clipping technique using polyglycolic acid (PGA) sheets. A, Filling the diverticulum with PGA sheets. B, Clipping in a zipper fashion after placement of PGA sheets compresses the actual bleeding site in spite of unsuccessful direct placement of hemoclips.
A 70-year-old man with a history of cardiac infarction and regular aspirin consumption presented with massive hematochezia (Video 1, available online at www.giejournal.org). Colonoscopy revealed active bleeding from the diverticulum in the ascending colon (Fig. 3A). Because the bleeding site in the diverticulum was not identified, hemoclips (HX-610-090; Olympus Medical Systems, Tokyo, Japan) were indirectly placed to close the diverticular orifice in a zipper-like fashion, and immediate hemostasis was achieved. Repeated indirect hemoclip placement was performed for active rebleeding the next day and 6 days after the initial endoscopic treatment. Aspirin was withdrawn the next day. Angiography and embolization by interventional radiology were considered when melena was observed on day 8. However, endoscopic treatment was attempted again at the patient's request. Colonoscopy revealed disengagement of the previous clips from the orifice of the treated diverticulum and active rebleeding (Fig. 3B). Therefore, we performed endoscopic clip closure using PGA sheets. First, the diverticulum was filled with 10-mm-square PGA sheets using biopsy forceps. The sheets were gently pressed and repeatedly inserted until the space of the cavity was completely filled. Second, fibrin glue was sprayed onto the sheets for fixation (Fig. 3C). Third, endoscopic clip closure of the diverticulum was performed, and immediate hemostasis was successfully achieved, without adverse events (Fig. 3D). The patient was followed up for 30 days after the last procedure and showed no recurrent hemorrhage despite resumption of aspirin on day 14. Filling the diverticulum with PGA sheets and performing subsequent clip closure can enable compression of the actual bleeding site despite inadequate direct placement of hemoclips. This method can be a viable option for endoscopic treatment of refractory diverticular hemorrhage.
Figure 3.
Endoscopic view of hemostasis for refractory colonic diverticulum bleeding by clipping after filling with polyglycolic acid sheets. A, Active bleeding from the diverticulum at the ascending colon during the initial procedure. B, The recurrent active bleeding from the treated diverticulum after the last procedure. C, The diverticulum is filled with polyglycolic acid sheets and fixed with fibrin glue. D, The orifice of the diverticulum is closed using multiple hemoclips, and hemostasis is completed.
Disclosure
All authors disclosed no financial relationships.
Supplementary data
Endoscopic clipping with polyglycolic acid sheets for colonic diverticulum bleeding.
References
- 1.Yen E.F., Ladabaum U., Muthusamy V.R. Colonoscopic treatment of acute diverticular hemorrhage using endoclips. Dig Dis Sci. 2008;53:2480–2485. doi: 10.1007/s10620-007-0151-4. [DOI] [PubMed] [Google Scholar]
- 2.Kaltenbach T., Watson R., Shah J. Colonoscopy with clipping is useful in the diagnosis and treatment of diverticular bleeding. Clin Gastroenterol Hepatol. 2012;10:131–137. doi: 10.1016/j.cgh.2011.10.029. [DOI] [PubMed] [Google Scholar]
- 3.Nakano K., Ishii N., Ikeya T. Comparison of long-term outcomes between endoscopic band ligation and endoscopic clipping for colonic diverticular hemorrhage. Endosc Int Open. 2015;3:E529–E533. doi: 10.1055/s-0034-1392510. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Setoyama T., Ishii N., Fujita Y. Enodoscopic band ligation (EBL) is superior to endoscopic clipping for the treatment of colonic diverticular hemorrhage. Surg Endosc. 2011;25:3574–3578. doi: 10.1007/s00464-011-1760-8. [DOI] [PubMed] [Google Scholar]
- 5.Witte J.T. Band ligation for colonic bleeding: modification of multiband ligating devices for use with a colonoscope. Gastrointest Endosc. 2000;52:762–765. doi: 10.1067/mge.2000.109872. [DOI] [PubMed] [Google Scholar]
- 6.Ishii N., Setoyama T., Deshpande G.A. Endoscopic band ligation for colonic diverticular hemorrhage. Gastrointest Endosc. 2012;75:382–387. doi: 10.1016/j.gie.2011.07.030. [DOI] [PubMed] [Google Scholar]
- 7.Ueda K., Tanaka T., Hayashi M. Mesh-based pneumostasis contributes to preserving gas exchange capacity and promoting rehabilitation after lung resection. J Surg Res. 2011;167:e71–e75. doi: 10.1016/j.jss.2009.11.009. [DOI] [PubMed] [Google Scholar]
- 8.Takeuchi J., Suzuki H., Murata M. Clinical evaluation of application of polyglycolic acid sheet and fibrin glue spray for partial glossectomy. J Oral Maxillofac Surg. 2013;71:e126–e131. doi: 10.1016/j.joms.2012.08.012. [DOI] [PubMed] [Google Scholar]
- 9.Takimoto K., Toyonaga T., Matsuyama K. Endoscopic tissue shielding to prevent delayed perforation associated with endoscopic submucosal dissection for duodenal neoplasms. Endoscopy. 2012;44:E414–E415. doi: 10.1055/s-0032-1325739. [DOI] [PubMed] [Google Scholar]
- 10.Sakaguchi Y., Tsuji Y., Ono S. Polyglycolic acid sheets with fibrin glue can prevent esophageal stricture after endoscopic submucosal dissection. Endoscopy. 2015;47:336–340. doi: 10.1055/s-0034-1390787. [DOI] [PubMed] [Google Scholar]
- 11.Nagami Y., Fukunaga S., Kanamori A. Endoscopic closure using polyglycolic acid sheets for delayed perforation after colonic endoscopic submucosal dissection. Endoscopy. 2020;52:E11–E12. doi: 10.1055/a-0978-4501. [DOI] [PubMed] [Google Scholar]
Associated Data